18C2057R-FCC-RF Exposure-Wireless Charge Rack-CN85-WCR-V1.0 0117

FCC ID: HD5-CX85WCR

RF Exposure Info

Download: PDF
FCCID_4132590

          RF Exposure Evaluation Declaration


            Product Name : Wireless Charge Rack
            Model No.              : CN85-WCR
            FCC ID                 : HD5-CX85WCR




       Applicant : HONEYWELL INTERNATIONAL INC
                   Honeywell Safety and Productivity Solutions
       Address : 9680 OLD BAILES RD
                   FORT MILL SC 29707-7539




               Date of Receipt : Dec. 12, 2018
               Test Date                   Dec. 13, 2018~ Dec. 31, 2018
               Issued Date             : Jan. 07, 2019
               Report No.              : 18C2057R-RF-US-P20V01
               Report Version : V1.0




The test results relate only to the samples tested.
The test results shown in the test report are traceable to the national/international standard through the
calibration of the equipment and evaluated measurement uncertainty herein.
This report must not be used to claim product endorsement by A2LA or any agency of the government.
The test report shall not be reproduced without the written approval of DEKRA Testing and Certification
(Suzhou) Co., Ltd.


Report No: 18C2057R-RF-US-P20V01



                    Tes t R e p o r t C e r t i f i c a t i o n
                                                            Issued Date : Jan. 07, 2019
                                                          Report No. : 18C2057R-RF-US-P20V01



     Product Name          :   Wireless Charge Rack
     Applicant             :   HONEYWELL INTERNATIONAL INC
                               Honeywell Safety and Productivity Solutions
     Address               :   9680 OLD BAILES RD
                               FORT MILL SC 29707-7539
     Manufacturer          :   1.HONEYWELL INTERNATIONAL INC
                               Honeywell Safety and Productivity Solutions
                               2.RAYVAL (SUZHOU) TECHNOLOGIES CO LTD
                               3.Metro(Suzhou)Technologies Co.,Ltd
     Address               :   1.9680 OLD BAILES RD
                               FORT MILL SC 29707-7539
                               2.SUCHUN INDUSTRIAL SQUARE, BLDG 15A 428 XINGLONG STR
                               SUZHOU INDUSTRIAL PARK SUZHOU JIANGSU 215126 CHINA
                               3.No.221 Xinghai street China-Singapore Suzhou Industrial Park
     Model No.             :   CN85-WCR
     FCC ID                :   HD5-CX85WCR
     Brand Name            :   Honeywell
     EUT Voltage           :   AC 120V/60Hz
     Applicable Standard   :   KDB 680106 D01 RF Exposure Wireless Charging Apps v03
     Test Result           :   Complied
     Performed Location    :   DEKRA Testing and Certification (Suzhou) Co., Ltd.
                               No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu,
                               China
                               TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098
                               FCC Delegation Number: CN1199
         Documented By     :



                                                       ( Adm. Specialist: Kitty Li )
          Reviewed By      :


                                                (Senior Project Manager: Frank He )
          Approved By      :



                                               (Engineering Supervisor: Jack Zhang)



                                       Page: 2 of 19


Report No: 18C2057R-RF-US-P20V01


      1. General Information
         1.1. EUT Description
Product Name                       Wireless Charge Rack
Model No.                          CN85-WCR
Working Voltage                    AC 120V/60Hz
Frequency Range                    110kHz~145KHz
Type of Modulation                 ASK




                                         Page: 3 of 19


Report No: 18C2057R-RF-US-P20V01


     1.2.   Antenna information
Model No.               N/A
Antenna manufacturer    N/A
Antenna Delivery              1*TX+1*RX                  2*TX+2*RX     3*TX+3*RX
Antenna technology            SISO
                                                Basic
                                                CDD
                              MIMO
                                                Sectorized
                                                Beam-forming
Antenna Type                                    Dipole
                              External
                                                Sectorized
                                                PIFA
                                                PCB
                              Internal          Ceramic Chip Antenna
                                                Loop antenna
                                                Type F antenna




                                         Page: 4 of 19


Report No: 18C2057R-RF-US-P20V01


        1.3.   Mode of Operation
DEKRA has verified the construction and function in typical operation. All the test modes were
carried out with the EUT in normal operation, which was shown in this test report and defined as:


Test Mode
Mode 1: Transmit


Note:
1. Regards to the frequency band operation: the lowest、middle and highest frequency of channel
  were selected to perform the test, then shown on this report.
2. For portable device, radiated spurious emission was verified over X, Y, Z Axis, and shown the
  worst case on this report.




                                          Page: 5 of 19


Report No: 18C2057R-RF-US-P20V01


        1.4.   Tested System Details
The types for all equipments, plus descriptions of all cables used in the tested system (including
inserted cards) are:


Product            Manufacturer           Model No.          Serial No.        Power Cord
1 N/A              N/A                    N/A                N/A               N/A




                                           Page: 6 of 19


Report No: 18C2057R-RF-US-P20V01


      1.5.    Configuration of Tested System


Test setup Diagram- Radiated Emission




                                        Page: 7 of 19


Report No: 18C2057R-RF-US-P20V01


     1.6.    EUT Exercise Software

 1   Setup the EUT and simulators as shown on above.
 2   Turn on the power of equipment.
 3   Start to continue transmit.




                                          Page: 8 of 19


Report No: 18C2057R-RF-US-P20V01


      2. Technical Test

         2.1. Test Environment

            Items                  Required (IEC 68-1)    Actual
Temperature (C)                         15-35             21
Humidity (%RH)                           25-75             50
Barometric pressure (mbar)              860-1060         950-1000




                                     Page: 9 of 19


Report No: 18C2057R-RF-US-P20V01


       3. Electric Field Strength

          3.1. Test Equipment

 Electric Field Strength / AC-6
 Instrument                       Manufacturer    Type No.        Serial No.     Cal. Date       Cal. Due Date
 Spectrum Analyzer                Agilent         N9010A          MY48030494     2018.01.07      2019.01.06
 Loop Antenna                     R&S             HFH2-Z2         833799/003     2018.11.26      2019.11.25
 MAGNETIC FIELD
 HiTESTER                         HIOKI  FT3470-51 1009-B1                       2018.10.11      2019.10.10
                                         SUCOFLEX
 Coaxial Cable              Huber+Suhner 106       AC2-C                         2018.03.02      2019.03.01
 Temperature/Humidity Meter Zhicheng     ZC1-2     AC2-TH                        2018.01.08      2019.01.07
 Note: All equipment are calibrated with traceable calibrations. Each calibration is traceable to the national or
 international standards.




                                                 Page: 10 of 19


Report No: 18C2057R-RF-US-P20V01


         3.2. Test Setup

    3kHz~10MHz Test Setup:




                                   Page: 11 of 19


Report No: 18C2057R-RF-US-P20V01


         3.3. Setup Photo




                                   Page: 12 of 19


Report No: 18C2057R-RF-US-P20V01


         3.4. Limit

    According to KDB 680106 D01v03 Clause 3.c: For devices designed for typical desktop
    applications, such a wireless charging pads, RF exposure evaluation should be conducted
    assuming a user separation distance of 15 cm. E and H field strength measurements or
    numerical modeling may be used to demonstrate compliance. Measurements should be
    made from all sides and the top of the primary/client pair, with the 15 cm measured from the
    center of the probe(s) to the edge of the device. Emissions between 100 kHz to 300 kHz
    should be assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m and
    1.63 A/m.

         3.5. Test Procedure

    a.   Set the measurement frequency of the measurement probe to the fundamental
         frequency of the device under test.
    b.   Set the span to encompass the entire emission bandwidth.
    c.   Set the RBW greater than the 99% OBW of the fundamental emission.
    Note: This step is not required for a broadband measurement probe that integrates the entire
         frequency range.
    d.   Set the detector to Peak and trace display to Max-Hold.
    e.   Allow the spectrum to fill; for pulsing devices this may require an increased monitoring
         period.
    f.   Using a marker, set it to the maximum level of the spectral envelope.
    g.   Repeat steps (b) to (f) while scanning a parallel plane at the measurement distance of
         10cm on each side of the device to find the peak level.
    h.   Repeat steps (b) to (g) for any frequencies where the field value is greater than -20 dBc
         below the maximum level identified.
    i.   If there are multiple frequencies transmitted by the device under test, use equations (2)
         and (3) to determine compliance.
    Note: When scanning around the entire device, the location found to be the maximum for the
         E- or H-field may not be the same location as the opposite field.




                                         Page: 13 of 19


Report No: 18C2057R-RF-US-P20V01


         3.6. Uncertainty
    The measurement uncertainty is defined as ± 3.80 dB




                                      Page: 14 of 19


Report No: 18C2057R-RF-US-P20V01


         3.7. Test Result


                              Maximum    Maximum
                                                     Limit
                      Axial    Freq.      Level              Result
                                                     (V/m)
                               (kHz)       (mV/m)

                        X     110~145      18.123    307     Pass

                        Y     110~145      25.704    307     Pass

                        Z     110~145      9.1568    307     Pass

                              Maximum    Maximum
                                                     Limit
                      Axial    Freq.      Level              Result
                                                     (A/m)
                               (kHz)       (μA/m)

                       X      110~145      362.46    0.815 Pass

                       Y      110~145      514.08    0.815 Pass

                       Z      110~145      183.14    0.815 Pass




                                    Page: 15 of 19


Report No: 18C2057R-RF-US-P20V01




X Axial-E Field:




Y Axial-E Field:




                                   Page: 16 of 19


Report No: 18C2057R-RF-US-P20V01


Z Axial-E Field:




X Axial-H Field:




                                   Page: 17 of 19


Report No: 18C2057R-RF-US-P20V01


Y Axial-H Field:




  Z Axial-H Field:




                                   Page: 18 of 19


Report No: 18C2057R-RF-US-P20V01


4. RF Exposure Evaluation

WPT Device requirement
    Wireless power transfer frequency is below 1 MHz;

    Output power from each primary coil is less than or equal to 15 watts;

    The transfer system includes only single primary and secondary coils. This includes charging
    systems that may have multiple primary coils and clients that are able to detect and allow
    coupling only between individual pairs of coils.
    Client device is placed directly in contact with the transmitter;

    Mobile exposure conditions only (portable exposure conditions are not covered by this
    exclusion).
    The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top
    surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the
    MPE limit.


Note: The WPT device can maintain all the six conditions above, so the RF exposure can be
exempted.



                                              The End




                                            Page: 19 of 19



Document Created: 2019-04-01 22:56:23
Document Modified: 2019-04-01 22:56:23

© 2024 FCC.report