Test Report HAC RF Appendix C

FCC ID: HD5-CT60L1N

Test Report

Download: PDF
FCCID_3907151

Calibration
      .     Laboratory of                                        8\\\\‘w/,,/.                              S      Schweizerischer Kalibrierdienst
Schm!d & I?artner                                                $
                                                                inz
                                                                              ~
                                                                                                           ( Service suisse d‘étalonnage
   Englneermg AG                                                i}B/REIIIRi?E                              5      Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                     y n                                              Swiss Calibration Service



Accredited by the Swiss Accreditation Service (SAS)                                                         Accreditation No.: SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Client      Sporton (Auden)                                                                    Certificate No: CD2450V3—1186_Jan18

CALIBRATION CERTIFICATE

 Object                                CD2450V3 — SN: 1186


 Calibration procedure(s)              QA CAL—20.v6
                                       Calibration procedure for dipoles in air



 Calibration date:                    January 09, 2018

 This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (S1).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 x 3)°C and humidity < 70%.

 Calibration Equipment used (M&TE critical for calibration)
 Primary Standards                      ID #                      Cal Date (Certificate No.)                           Scheduled Calibration
 Power meter NRP                        SN:    104778             04—Apr—17   (No.   217—02521/02522)                  Apr—18
 Power sensor NRP—Z91                   SN:    103244             04—Apr—17   (No.   217—02521)                        Apr—18
 Power sensor NRP—Z91                   SN:    103245             04—Apr—17   (No.   217—02522)                        Apr—18
 Reference 20 dB Attenuator             SN:    5058 (20k)         07—Apr—17   (No.   217—02528)                        Apr—18
 Type—N mismatch combination            SN:    5047.2 / 06327     07—Apr—17   (No.   217—02529)                        Apr—18
 Probe EF3DV3                           SN:    4013               14—Jun—17   (No.   EF3—4013_Jun17)                   Jun—18
 DAE4                                   SN: 781                   13—Jul—17 (No. DAE4—781_Jul17)                       Jul—18



 Secondary Standards                    ID #                      Check Date (in house)                                Scheduled Check
 Power meter Agilent 44198              SN: GB42420191            09—Oct—09 (in house check Oct—17)                    In house check: Oct—20
 Power sensor HP E4412A                 SN: US38485102            05—Jan—10 (in house check Oct—17)                    In house check: Oct—20
 Power sensor HP 8482A                  SN: US37205597            09—Oct—08 (in house check Oct—17)                    In house check: Oct—20
 RF generator R&S SMT—06                SN: 832283/011            27—Aug—12 (in house check Oct—17)                    In house check: Oct—20
 Network Analyzer HP 8753E              SN: US37390585            18—Oct—01 (in house check Oct—17)                    In house check: Oct—18

                                        Name                                   Function                                Signature
 Calibrated by:                         Leif Klysner                           Laboratory Technician                 W Eg;



 Approved by:                          Katja Pokovie                           Technical Manager                  /m:



                                                                                                                      Issued: January 10, 2018
 This calibration certificate shall not be reproduced except in full without written approvalof the laboratory.




Certificate No: CD2450V3—1186_Jan18                         Page 1 of 5


Calibration Laboratory of
Schmid & Partner                                                                           s    Schweizerischer Kalibrierdienst
                                                                                           C    Service suisse d'etalonnage
 Engineering AG                                                                                 Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                               s    Swiss Calibration Service

Accredited by the Swiss Accreditation Service (SAS)                                         Accreditation No.:   SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates


References
[1]       ANS1-C63.19-2011
          American National Standard, Methods of Measurement of Compatibility between Wireless Communications
          Devices and Hearing Aids.
Methods Applied and Interpretation of Parameters:
      •   Coordinate System: y-axis is in the direction of the dipole arms. z-axis is from the basis of the antenna
          (mounted on the table) towards its feed point between the two dipole arms. x-axis is normal to the other axes.
          In coincidence with the standards [1 J, the measurement planes (probe sensor center) are selected to be at a
          distance of 15 mm above the top metal edge of the dipole arms.
      •   Measurement Conditions: Further details are available from the hardcopies at the end of the certificate. All
          figures stated in the certificate are valid at the frequency indicated. The forward power to the dipole connector
          is set with a calibrated power meter connected and monitored with an auxiliary power meter connected to a
          directional coupler. While the dipole under test is connected, the forward power is adjusted to the same level.
      •   Antenna Positioning: The dipole is mounted on a HAC Test Arch phantom using the matching dipole
          positioner with the arms horizontal and the feeding cable coming from the floor. The measurements are
          performed in a shielded room with absorbers around the setup to reduce the reflections.
          It is verified before the mounting of the dipole under the Test Arch phantom , that its arms are perfectly in a
          line. It is installed on the HAC dipole positioner with its arms parallel below the dielectric reference wire and
          able to move elastically in vertical direction without changing its relative position to the top center of the Test
          Arch phantom. The vertical distance to the probe is adjusted after dipole mounting with a DASY5 Surface
          Check job. Before the measurement, the distance between phantom surface and probe tip is verified. The
          proper measurement distance is selected by choosing the matching section of the HAC Test Arch phantom
          with the proper device reference point (upper surface of the dipole) and the matching grid reference point (tip
          of the probe) considering the probe sensor offset. The vertical distance to the probe is essential for the
          accuracy.
      •   Feed Point Impedance and Return Loss: These parameters are measured using a HP 8753E Vector Network
          Analyzer. The impedance is specified at the SMA connector of the dipole. The influence of reflections was
          eliminating by applying the averaging function while moving the dipole in the air, at least 70cm away from any
          obstacles.

      •   E-field distribution: E field is measured in the x-y-plane with an isotropic ER3D-field probe with 100 mW
          forward power to the antenna feed point. In accordance with [1], the scan area is 20mm wide, its length
          exceeds the dipole arm length (180 or 90mm). The sensor center is 15 mm (in z) above the metal top of the
          dipole arms. Two 30 maxima are available near the end of the dipole arms. Assuming the dipole arms are
          perfectly in one line, the average of these two maxima (in subgrid 2 and subgrid 8) is determined to
          compensate for any non-parallelity to the measurement plane as well as the sensor displacement. The E-field
          value stated as calibration value represents the maximum of the interpolated 30-E-field, in the plane above
          the dipole surface.




 The reported uncertainty of measurement is stated as the standard uncertainty of measurement multiplied by the
 coverage factor k=2, which for a normal distribution corresponds to a coverage probability of approximately 95%.




Certificate No: CD2450V3-1186_Jan 18                   Page 2 of 5


 Measurement Conditions
     DASY system confiquration, as far as not given on paae 1.
      DASY Version                                             DASY5                           V52.10.0
      Phantom                                              HAG Test Arch
      Distance Dipole Top - Probe Center                      15mm
      Scan resolution                                      dx, dy=5 mm
      Frequency                                        2450 MHz ± 1 MHz
      Input power drift                                      < 0.05 dB



Maximum Field values at 2450 MHz

      E-field 15 mm above dipole surface                         condition             Interpolated maximum
      Maximum measured above high end                       100 mW input power         87.8 Vim= 38.86 dBVim
      Maximum measured above low end                        100 mW input power         86.8 Vim= 38.77 dBVim
      Averaged maximum above arm                            100 mW input power         87.3 Vim ± 12.8 % (k=2)



Appendix (Additional assessments outside the scope of SCS 0108)

Antenna Parameters

      Frequency                                                Return Loss                   Impedance
      2250 MHz                                                    16.3 dB                   65.7 Q + 8.2 jQ
      2350 MHz                                                    26.1 dB                   54.2 Q - 3.0 jQ
      2450 MHz                                                    31.6 dB                   52.4 Q - 1.3 jQ
      2550 MHz                                                    39.2 dB                  50.9 Q + 0.7 jQ
      2650 MHz                                                    16.6 dB                   67.1 Q - 3.0 jQ


3.2 Antenna Design and Handling

The calibration dipole has a symmetric geometry with a built-in two stub matching network, which leads to the
enhanced bandwidth.
The dipole is built of standard semirigid coaxial cable. The internal matching line is open ended. The antenna is
therefore open for DC signals.
Do not apply force to dipole arms, as they are liable to bend. The soldered connections near the feedpoint may be
damaged. After excessive mechanical stress or overheating, check the impedance characteristics to ensure that the
internal matching network is not affected.

After long term use with 40W radiated power, only a slight warming of the dipole near the feedpoint can be measured.




Certificate No: CD2450V3-1186_Jan18          Page 3 of 5


Impedance Measurement Plot




                                                                             9 Jan 2018 10:02:51
          IQ!IJ S11     LOG        5 dB i REF -18 dB                    1 : -31.579 dB 2 450.000 000 MHz

                                  ~---,f---•---~--+- --+---+
          *
                                   ---·----                   +-- -...__- -+- -
                                                                                     I       +
                                                                                                                 CH1 Markers
                                                                                                                 2:-16. 317 dB
          Cor                                                                                                    2. 25000 GHz
                                                                                                                 3:-26.075 dB
                                                                                                                  2. 35000 GHz
                                                                                                                 4:-39.167 dB
          Avg             ---~---+                                                                               2. 55000 GHz
          16                                                                                                     5:-16.581 dB
                                                                                                     +- - -      2.65000 GHz

          Hld

          CH2 S11       1 U FS           1: 52. 371   o   -1.2813   o 50. 701   pF          2 450. 000 000 MHz



                                                                                                                 CH2 Markers
                                                                                                                  2: 55. 707 o
          Cor                                                                                                        8.2109 o
                                                                                                                 2.25000 GHz
                                                                                                                  3: 54. 238 o
                                                                                                                    -2. 9824 O
                                                                                                                 2. 35000 GHz
          Av9                                                                                                     4: 50.873 o
          16                                                                                                         0. 6777 o
                                                                         L                                       2.55000 GHz
                                                                                                                  5: 6 7.109 {l
          Hld                                                                                                      -2. 9844 O
                                                                                                                 2.65000 GHz
                      CENTER 2 450. 000 000 MHz                                      SPAN 1 000.000 000 MHz




Certificate No: CD2450V3·1186_Jan18               Page 4 of 5


DASYS E-field Result

                                                                                              Date: 09.01.2018

Test Laboratory: SPEAG Lab2

DUT: HAC Dipole 2450 MHz; Type: CD2450V3; Serial: CD2450V3 - SN: 1186

Communication System: UID O - CW ; Frequency: 2450 MHz
Medium parameters used: cr = 0 S/m, Er = 1; p = I 000 kg/m3
Phantom section: RF Section
Measurement Standard: DASYS (IEEE/IEC/ANSI C63.19-201 l)

DASY52 Configuration:

    •   Probe: EF3DV3 - SN4013; ConvF(l, 1, 1); Calibrated: 14.06.2017;
    •   Sensor-Surface: (Fix Surface)
    •   Electronics: DAE4 Sn781; Calibrated : 13.07.2017
    •   Phantom: HAC Test Arch with AMCC; Type: SD HAC POl BA; Serial : 1070
    •   DASY52 52.10.0(1446); SEMCAD X 14.6.10(7417)


Dipole E-Field measurement@ 24SOMHz/E-Scan - 2450MHz d=lSmm/Hearing Aid Compatibility Test (41x181xl):
Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value= 77.23 V/m; Power Drift= -0.02 dB
Applied MIF = 0.00 dB
RF audio interference level= 38.86 dBV/m
Emission category: M2
                                         MIF scaled E-field

                                          Grid 1 M2     Grid 2 M2         Grid 3 M2
                                          38.46dBV/m 38.77 dBV/m 38.7 dBV/m

                                          Grid 4 M2     Grid 5 M2     Grid 6 M2
                                          37.75 dBV/m 37.94 dBV/m 37.87 dBV/m

                                          Grid 7 M2     Grid 8 M2     Grid 9 M2
                                          38.6 dBV/m    38.86 dBV/m 38.76 dBV/m


        dB
        0


        -1.31


        -2.62


        -3.92


        -5.23


        -6.54
                  0 dB= 87.75 V/m = 38.86 dBV/m



Certificate No: CD2450V3·1186_Jan18             Page 5 of 5


    Calibration Laboratory of
                                                                                                                S     Schweizerischer Kalibrierdienst
    Schmid & Partner                                                                                                  Service suisse d'etalonnage
     Engineering AG                                                                                             C     Servizio svizzero di taratura
    Zeughausstrasse 43, 8004 Zurich, Switzerland                                                                s     Swiss Calibration Service


    Accredited by the Swiss Accreditation Service (SAS)                                             Accreditation No.:    SCS 0108
    The Swiss Accreditation Service is one of the signatories to the EA
    Multilateral Agreement for the recognition of calibration certificates

    Client       Sporton (Auden)                                                                    Certificate No:   DAE4-853_Jul17

I   CALIBRATION CERTIFICATE
     Object                               DAE4 - SD 000 D04 BM - SN: 853


     Calibration procedure(s)             QA CAL-06.v29
                                          Calibration procedure for the data acquisition electronics (DAE)



     Calibration date:                    July 19, 2017




    This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (SI).
    The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


    All calibrations have been conducted in the closed laboratory facility: environment temperature (22 ± 3)°C and humidity < 70% .


    Calibration Equipment used (M&TE critical for calibration)


    Primary Standards                                                 Cal Date (Certificate No.)                          Scheduled Calibration
    Keithley Multimeter Type 2001         J   SN: 0810278             09-Sep-16 (No: 19065)                               Sep-17

    Secondary Standards                       ID #                    Check Date (in house)                               Scheduled Check
    Auto DAE Calibration Unit                 SE UWS 053 AA 1001     05-Jan-17 (in house check)                           In house check: Jan-18
    Calibrator Box V2.1                       SE UMS 006 AA 1002     05-Jan-17 (in house check)                           In house check: Jan-18




                                              Name                                Function                                Signature
    Calibrated by:                            Eric Hainfeld                       Laboratory Technician



    Approved by:                           Sven Kuhn                              Deputy Manager



                                                                                                                          Issued: July 19, 2017
    This calibration certificate shall not be reproduced except in full without written approval of the laboratory.




Certificate N o: DAE4-853_Ju l17                                         Page 1 of 5


Calibration Laboratory of
                                                                              S   Schweizerischer Kalibrierdienst
Schmid & Partner                                                              C   Service suisse d'etalonnage
 Engineering AG                                                                   Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland
                                                                              S   Swiss Calibration Service


 Accredited by the Swiss Accreditation Service (SAS)                          Accreditation No.:   SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
 Multilateral Agreement for the recognition of calibration certificates



Glossary
DAE                          data acquisition electronics
Connector angle              information used in DASY system to align probe sensor X to the robot
                             coordinate system.

Methods Applied and Interpretation of Parameters
  •   DC Voltage Measurement: Calibration Factor assessed for use in DASY system by
     comparison with a calibrated instrument traceable to national standards. The figure given
     corresponds to the full scale range of the voltmeter in the respective range.
     •    Connector angle: The angle of the connector is assessed measuring the angle
          mechanically by a tool inserted. Uncertainty is not required .
     •    The following parameters as documented in the Appendix contain technical information as a
          result from the performance test and require no uncertainty.
          •    DC Voltage Measurement Linearity: Verification of the Linearity at +10% and -10% of
               the nominal calibration voltage. Influence of offset voltage is included in this
               measurement.
          •    Common mode sensitivity: Influence of a positive or negative common mode voltage on
               the differential measurement.
          •    Channel separation: Influence of a voltage on the neighbor channels not subject to an
               input voltage.
         •     AD Converter Values with inputs shorted: Values on the internal AD converter
               corresponding to zero input voltage
         •     Input Offset Measurement Output voltage and statistical results over a large number of
               zero voltage measurements.
         •     Input Offset Current: Typical value for information; Maximum channel input offset
               current, not considering the input resistance.
         •     Input resistance: Typical value for information: DAE input resistance at the connector,
               during internal auto-zeroing and during measurement.
         •     Low Battery Alarm Voltage: Typical value for information. Below this voltage, a battery
               alarm signal is generated.
         •     Power consumption: Typical value for information . Supply currents in various operating
               modes.




Certificate No: DAE4-853_Jul17                                  Page 2 of 5


DC Voltage Measurement
    AID - Converter Resolution nominal
       High Range:       1LSB =        6.1µV,         full range= -100 ... +300 mV
       Low Range:        1LSB =         61 nV ,       full range= -1.. ..... +3mV
    DASY measurement parameters: Auto Zero Time: 3 sec; Measuring time: 3 sec

      Calibration Factors                  X                           y                    z
      High Range                 402.602 ± 0.02% (k=2)   403.267 ± 0.02% (k=2)   403.445   ± 0.02% (k=2)
      Low Range                  3.95476 ± 1.50% (k=2)   3.96544 ± 1.50% (k=2)   3.96662   ± 1.50% (k=2)

Connector Angle

      Connector Angle to be used in DASY system                                      134.5 ° ± 1 °




Certificate No: DAE4-853_Jul17                           Page 3 of 5


Appendix (Additional assessments outside the scope of SCS0108)
1. DC Vo taae Linearity
      High Range                               Reading (µV)         Difference (µV)               Error(%)
      Channel X        + Input                  200032.34                   -1.72                 -0.00
      ChannelX         + Input                   20007.23                   2.14                   0.01
      ChannelX         - Input                  -20002.92                   1.88                  -0.01
      ChannelV         + Input                  200032.83                  -1.31                  -0.00
      Channel V        + Input                  20004.73                   -0.35                  -0.00
      Channel V        - Input                  -20006.55                  -1.74                   0.01
      Channel Z        + Input                  200040.33                   6.37                   0.00
      ChannelZ         + Input                  20004.71                   -0.33                  -0.00
      Channel Z        - Input                  -20008.02                  -3.12                   0.02

      Low Range                                Reading (µV)         Difference (µV)               Error(%)
      ChannelX        + Input                    2001.66                    0.35                   0.02
      ChannelX        + Input                    201.67                     0.28                   0.14
      ChannelX        - Input                    -198.01                    0.61                  -0.31
      Channel V       + Input                    2001.27                    0.05                   0.00
      Channel V       + Input                    200.65                    -0.72                  -0.36
      ChannelY        - Input                    -199.27                   -0.58                   0.29
      ChannelZ        + Input                    2000.81                   -0.40                  -0.02
      ChannelZ        + Input                    199.74                    -1.51                  -0.75
      ChannelZ        - Input                    -200.02                   -1.26                   0.63



2. Common mode sensitivity
    DASY measurement parameters: Auto Zero T 1me: 3 sec; MeasunnQ time: 3 sec

                         Common mode                      High Range                           Low Range
                         Input Voltage (mV)           Average Reading (µV)                Average Reading (µV)

     Channel X                          200                     -6.81                           -8.25
                                       -200                     10.16                           8.50
     ChannelV                           200                      4.33                           4.41
                                       - 200                    -5.81                           -6.18
     Channel Z                          200                      2.40                           2.38
                                       -200                     -4.45                           -4.60



3. Channel separation
    DASV measuremenI parame ers: Auo
                                   I Zero T,me: 3 sec; Measunng ,me: 3 sec   r
                        Input Voltage (mV)        Channel X (µV)         Channel V (µV)       ChannelZ(µV)
     ChannelX                    200                       -                  1.24                 -2.01
     Channel V                   200                   7.20                        -               2.53
     Channel Z                   200                  10.31                   4.71                      -

Certificate No: DAE4-853_Jul17                             Page 4 of 5


4. AD-Converter Values with inputs shorted
   DASY measuremen t parameters: A uto Z ero T1me: 3 sec; MeasunnQ time: 3 sec

                                                    High Range (LSB)                        Low Range (LSB)

     Channel X                                              16247                                16895
     ChannelY                                               16088                                16351
     ChannelZ                                               16248                                17044



5. Input Offset Measurement
    DASY measurement parameters: Auto Zero Time: 3 sec; Measuring time: 3 sec
    Input 10MQ

                            Average (µV)                                                         Std. Deviation
                                                min. Offset (µV)         max. Offset (µV)
                                                                                                      (LLV)
     ChannelX                    -0.70                -1.52                       0.31                  0.39
     ChannelY                    -0.77                -1.78                       0.39                  0.37
     Channel Z                   0.22                 -1.06                       1.36                  0.47


6. Input Offset Current
     Nominal Input circuitry offset current on all channels: <25fA


7. Input Resistance         (Typical values for information)
                                                  Zeroing (kOhm)                           Measuring (MOhm)
     ChannelX                                              200                                   200
     ChannelY                                              200                                   200
     Channel Z                                             200                                   200


8. Low Batterv Al arm VI
                       o taae             (Typical values for information)
     Typical values                               Alarm Level (VDC)
     Supply(+ Vee)                                                                 +7.9
     Supply (- Vee)                                                                 -7.6


9. Power Consumpt1on             (Tvpical values for information)
     Typical values                         Switched off (mA)        Stand by (mA)            Transmitting (mA)
     Supply(+ Vee)                                 +0.01                     +6                        +14
     Supply (- Vee)                                -0.01                     -8                        -9




Certificate No: DAE4-853_Jul17                             Page 5 of 5


Calibration Laboratory of
Schmid & Partner
                                                                                                            s      Schweizerischer Kalibrierdienst
                                                                                                            C      Service suisse d'etalonnage
 Engineering AG                                                                                                    Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland
                                                                                                            s      Swiss Calibration Service


Accredited by the Swiss Accreditation Service (SAS)                                                         Accreditation No. :     SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Client      Sporton (Auden)                                                                    Certificate No:     EF3-4047_Jan18


CALIBRATION CERTIFICATE                                                                                                                              I
Object                                EF3DV3- SN:4047                                                                                          I


 Calibration procedure(s)             QA CAL-02.v8, QA CAL-25.v6
                                      Calibration procedure for E-field probes optimized for close near field
                                      evaluations in air

 Calibration date:                    January 8, 2018

 This calibration certificate documents the traceability to national standards, which realize the physical units of measuremen ts (SI).
 The measurements and t he uncertainties with confidence probability are given on the following pages and are part of t he certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22     ± 3)°C and humidity< 70% .

 Calibration Equipment used (M&TE critical for calibration)



 Primary Standards                   ID                                 Cal Date (Certificate No.)                    Scheduled Calibration
 Power meter NRP                     SN: 104778                         04-Apr-17 (No. 217-02521/02522)               Apr-18
 Power sensor NRP-291                SN: 103244                         04-Apr-17 (No. 217-02521)                     Apr-18
 Power sensor NRP-291                SN: 103245                         04-Apr-17 (No. 217-02525)                     Apr-18
 Reference 20 dB Attenuator          SN: S5277 (20x)                    07-Apr-17 (No. 217-02528)                     Apr-18
 Reference Probe ER3DV6              SN: 2328                           10-0ct-17 (No. ER3-2328 Oct17)                Oct-18
 DAE4                                SN: 789                            2-Aug-17 (No. DAE4-789 Aug17)                 Aug-18


 Secondary Standards                 ID                                 Check Date (in house)                         Scheduled Check
 Power meter E4419B                  SN: GB41293874                     06-Apr-16 (in house check Jun-16)             In house check: Jun-18
 Power sensor E44 12A                SN : MY41498087                    06-Apr-16 (in house check Jun-16)             In house check: Jun-18
  PowersensorE4412A                  SN : 000110210                     06-Apr-16 (in house check Jun-16)             In house check: Jun-18
  RF generator HP 8648C              SN: US3642U01700                   04-Aug-99 (in house check Jun-16)             In house check: Jun-18
  Network Analyzer HP 8753E          SN: US37390585                     18-0ct-0 1 (in house check Oct-17)            In house check: Oct-18

                                          Name                                 Function                                 Signature
 Calibrated by:                         Michael Weber                          Laboratory Technician

                                                                                                                       &r
 Approved by:                           Katja Pokovic                          Technical Manager
                                                                                                                   ~re~_
                                                                                                                        Issued : January 9, 2018
 This calibration certificate shall not be reproduced except in full without written approval of the laboratory.




Certificate No: EF3-4047_Jan18                                        Page 1 of 11


                                                               $ 9m
Calibration Laboratory of                                     S i\b// 7                       Schweizerischer Kalibrierdienst




                                                          )C             °C
                                                            7
Schmid & Partner                                                                              Service suisse d‘étalonnage
  Engineering AG                                                                              Servizio svizzero di taratura
                                                              7          3




                                                            w
Zeughausstrasse 43, 8004 Zurich, Switzerland                                                  Swiss Calibration Service
                                                                Yolstie®

Accredited by the Swiss Accreditation Service (SAS)                                        Accreditation No.: SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Glossary:
NORMx,y,z                    sensitivity in free space
DCP                          diode compression point
CF                           crest factor (1/duty_cycle) of the RF signal
A, B,C, D                    modulation dependent linearization parameters
Polarization q               i rotation around probe axis
Polarization 8               8 rotation around an axis that is in the plane normal to probe axis (at measurement center),
                             Le., 9 = 0 is normal to probe axis
Connector Angle              information used in DASY system to align probe sensor X to the robot coordinate system

Calibration is Performed According to the Following Standards:
    a)   IEEE Std 1309—2005, " IEEE Standard for calibration of electromagnetic field sensors and probes, excluding
         antennas, from 9 kHz to 40 GHz", December 2005
    b)   CTIA Test Plan for Hearing Aid Compatibility, Rev 3.0, November 2013

Methods Applied and Interpretation of Parameters:
    *    NORMx,y,z: Assessed for E—field polarization 3 = 0 for XY sensors and 3 = 90 for Z sensor {f < 900 MHz in
         TEM—cell; f > 1800 MHz: R22 waveguide).
    *    NORM(Ax,y,z = NORMx,y,z * frequency_response (see Frequency Response Chart).
    «_   DCPx,y,z: DCP are numerical linearization parameters assessed based on the data of power sweep with CW
         signal (no uncertainty required). DCP does not depend on frequency nor media.
    *    PAR: PAR is the Peak to Average Ratio that is not calibrated but determined based on the signal
         characteristics
    *    Axsy.zBxy.z; Coy.2; Dx,y,2; VRxy,z: A, B, C, D are numerical linearization parameters assessed based on
         the data of power sweep for specific modulation signal. The parameters do not depend on frequency nor
         media. VR is the maximum calibration range expressed in RMS voltage across the diode.
    *    Spherical isotropy (3D deviation from isotropy): in a locally homogeneous field realized using an open
         waveguide setup.
    «_   Sensor Offset: The sensor offset corresponds to the offset of virtual measurement center from the probe tip
         (on probe axis). No tolerance required.
    «_   Connector Angle: The angle is assessed using the information gained by determining the NORMx (no
         uncertainty required).




Certificate No: EF3—4047_Jan18                                    Page 2 of 11


EF3DV3 - SN:4047                                                                January 8, 2018




                      Probe EF3DV3

                                         SN:4047

                                  Manufactured:            May 24, 2016
                                  Calibrated:              January 8, 2018




                                 Calibrated for DASY/EASY Systems
                                    (Note: non-compatible with DASY2 system!)




Certificate No: EF3-4047_Jan18                    Page 3 of 11


EF3DV3 - SN:4047                                                                                                             January 8, 2018




DASY/EASY - Parameters of Probe: EF3DV3 - SN:4047

Basic Calibration Parameters
                                               SensorX                           SensorY                    SensorZ               Unc (k=2)
 Norm /,,V/(V/m)    2
                        )                         0.80                            0.65                         1.27               ± 10.1 %
 DCP (mV\ 0                                       96.8                            99.5                         95.6



Modulation Calibration Parameters
 UID           Communication System Name                                   A           B            C           D         VR          Unc"'
                                                                           dB       dByµV                      dB         mV          (k=2)
 0             cw                                                X        0.0         0.0          1.0        0.00       137.5       ±3.3 %
                                                                 y        0.0         0.0          1.0                   158.8
                                                                  z       0.0         0.0          1.0                   169.9
 10061-        IEEE 802.11 b WiFi 2.4 GHz (DSSS, 11               X       3.63       73.1         21.5        3.60       131.3       ±0.7%
 CAB           Mbns1
                                                                  y      4.00         74.4        22.0                   111.4
                                                                  z      3.15         70.4        20.4                   118.6
 10069-        IEEE 802.11a/h WiFi 5 GHz (OFDM, 54                X      11.46        71.0        24.8       10.56       138.5       ±3.0 %
 CAC           Mbns\
                                                                  y      10.98        69.5         23.7                  113.8
                                                                  z      10.80        69.4         23.8                  119.7
 10077-        IEEE 802.11g WiFi 2.4 GHz                          X      10.23        69.8         24.7       11.00      115.0       ±3.3 %
 CAB           (DSSS/OFDM, 54 Mbns1
                                                                  y      10.74        71.4         25.5                  134.0
                                                                  z      10.32        70.6         25.3                  138.6



 The reported uncertainty of measurement is stated as the standard uncertainty of measurement
 multiplied by the coverage factor k=2, which for a normal distribution corresponds to a coverage
 probability of approximately 95%.

8
  Numerical linearization parameter: uncertainty not required.
e Uncertainty is determined using the max. deviation from linear response applying rectangular distribution and is expressed for the square of the
field value.




Certificate No: EF3-4047_Jan18                                        Page4of11


EF3DV3 — SN:4047                                                                                                                               January 8, 2018


                                                               Frequency Response of E—Field
                                                                         (TEM—Cell:ifi110 EXX, Waveguide: R22)
          Frequency response (normalized)




                                            .5       [FA_AL_L_L_    LE           1    oc      uccf   ob   uU    I     1   4    |     1_|
                                                 0                 500         1000           1500             2000           2500
                                                             _                        k       t [MHz]                                o
                                                             *                         *                    &                        *
                                                         TEM_(IO")                    2(0°)               TEE@O")                  R22 (90°)


                                                             Uncertainty of Frequency Response of E—field: £ 6.3% (k=2)




Certificate No: EF3—4047_Jan18                                                           Page 5 of 11


EF3DV3 — SN:4047                                                                                            January 8, 2018




                                  Receiving Pattern (¢), 9 = 0°

                    f=600 MHz,TEM,0°                                              £=1800 MHz,R22,0°




           120            ~   c# %, '04 s os             P                  hi        |   >   ‘   bo -oz os os




            e            e              e                e                   O        e       s     e            e
            Tot          X              Y                2                  Tot       X             ¥            Z




                                 Receiving Pattern (¢), 9 = 90°

                   f=600 MHz,TEM,90°                                              f=1800 MHz,R22,90°




           99                    ® os       on os   os   ?                  *4                © o2 o     os os   >




             L            &      s      e                e                   @        ¢       ®     ®            e
            Tot           X             Y                &                  Tot       X             Y            Z




Certificate No: EF3—4047_Jan18                               Page 6 of 11


EF3DV3 — SN:4047                                                                                          January 8, 2018



      Error {dB]                           Receiving Pattern (¢), 9 = 0°




                                           j -11)0 ‘
                                 —                                       Roll [*]
                              1UE:MJHZ                 SOE-.MJ—{Z                   18(“.;de      2507)!&%12


                                         Uncertainty of Axial Isotropy Assessment: £ 0.5% (k=2)




                                          Receiving Pattern (¢), 9 = 90°



                   0.5—.~~—
      Error [dB]




                   0.0————

                   067




                                                                          Rol []
                                                                                        * !           ®
                              100 MHz                  600 MHz                      1800 MHz


                                         Uncertainty of Axial Isotropy Assessment: £ 0.5% (k=2)




Certificate No: EF3—4047_Jan18                                      Page 7 of 11


EF3DV3 — SN:4047                                                                                                January 8, 2018




                                          Dynamic Range f(E—field)
                                                   {TEM cell , f= 900 MHz)




                       105




                       104

                   3
                   ©
                   5
                   i 10°
                   5
                   o:
                   &

                        102




                        10‘




                              10°                        101                          10                  10°
                                                                 E total [V/im]
                                                 4
                                           not compensated                            compensated



                              2

                              1—
                       a           L
                       2
                       é      0_ ..

                       d           L
                           4~

                           2                                      B               |                 |
                                  109                   101                       102               103
                                                                E total [V/m]

                                            riot compensated                      compensated


                                        Uncertainty of Linearity Assessment: £ 0.6% (k=2)




Certificate No: EF3—4047_Jan18                                 Page 8 of 11


EF3DV3 — SN:4047                                                                              January 8, 2018


                                 Deviation from Isotropy in Air
                                               Error (¢, 9), f = 900 MHz




                         —1.0    —0.8   —0.6   —0.4   —0.2   00    02   04   0.6   0.4   10

                            Uncertainty of Spherical Isotropy Assessment: * 2.6% (k=2)




Certificate No: EF3—4047_Jan18                          Page 9 of 11


EF3DV3 - SN:4047                                         January 8, 2018




DASY/EASY - Parameters of Probe: EF3DV3 - SN:4047

Other Probe Parameters
 Sensor Arrangement                                       Rectangular
 Connector Angle (°)                                             -30.2
 Mechanical Surface Detection Mode                            enabled
 Optical Surface Detection Mode                               disabled
 Probe Overall Length                                         337mm
 Probe Body Diameter                                           12mm
 Tip Length                                                    25mm
 Tip Diameter                                                   4mm
 Probe Tip to Sensor X Calibration Point                       1.5mm
 Probe Tip to Sensor Y Calibration Point                       1.5mm
 Probe Tip to Sensor Z Calibration Point                       1.5mm




Certificate No: EF3-4047_Jan18             Page 10of11


EF3DV3 - SN:4047                                                                                    January 8, 2018


Appendix (Additional assessments outside the scope of SCS 0108)


Calibration Parameters for 3-4 GHz
                                               SensorX                          SensorY   SensorZ      Unc (k=2)
 Norm lnV/(V/ml'l,,                               0.92                           0.75      1.40        + 10.1 %
 DCP (mV)"                                        96.8                           99.5      95.6


Calibration Parameters for 5-6 GHz
                                               SensorX                          SensorY   SensorZ      Unc (k=2)
 Norm lnV//V/mlT                                  1.10                           0.88      1.66        + 10.1 %
 DCP (mVl"                                        96.8                           99.5      95.6




 The reported uncertainty of measurement is stated as the standard uncertainty of measurement
 multiplied by the coverage factor k=2, which for a normal distribution corresponds to a coverage
 probability of approximately 95%.


a Numerical linearizat!on parameter: uncertainty not required.
x Calibration procedure for frequencies above 3 GHz is pending accreditation.




Certificate No: EF3-4047_Jan18                                   Page 11 of 11



Document Created: 2018-06-27 15:32:28
Document Modified: 2018-06-27 15:32:28

© 2024 FCC.report