SAR Test Report Annex C_3

FCC ID: HD5-CN85L1N

RF Exposure Info

Download: PDF
FCCID_4050456

Impedance Measurement Plot for Body TSL




                                                                 19 Jun 2018      @9:53:58
         (CHI sii     1 U FS          1 49.014 o   7.7324 n   502.31 pH          2450.000 00A MHz




         Del

         C#




         Avg
         16


         H1d

          CH2   S                                                         7 dB   _2 450.000




         Ca




          Av
          16°

          H1d

                    START 2 250.000 D00 MHz                               STOP 2 650.000 000 MHz




Certificate No: D2450V2—869_Jun18                    Page 8 of 8


Calibration
      .     Laboratory of                                         §Ax:~"                                   S      Schweizerischer Kalibrierdienst
Schmid & Partner                                                 M                                         c      Service suisse d‘étalonnage
  Engineering AG                                                 T /a >                                           Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                      7/I//—B\\\\\?                            S swiss Calibration Service
                                                                     Ulitals®

Accredited by the Swiss Accreditation Service (SAS)                                                        Accreditation No.: SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreementfor the recognition of calibration certificates

Client      Auden                                                                              Certificate No: D2600V2—1058_Jun18




 Object                               D2600V2 — SN:1058


 Calibration procedure(s)             QA CAL—05.v10
                                      Calibration procedure for dipole validation kits above 700 MHz



 Calibration date:                    June 19, 2018



 This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (S1).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 + 3)°C and humidity < 70%.


 Calibration Equipment used (M&TE critical for calibration)


 Primary Standards                      ID #                     Cal Date (Certificate No.)                            Scheduled Calibration
 Power meter NRP                        SN: 104778               04—Apr—18 (No. 217—02672/02673)                       Apr—19
 Power sensor NRP—Z91                   SN: 103244               04—Apr—18 (No. 217—02672)                             Apr—19
 Power sensor NRP—Z91                   SN: 103245               04—Apr—18 (No. 217—02673)                             Apr—19
 Reference 20 dB Attenuator             SN: 5058 (20k)           04—Apr—18 (No. 217—02682)                             Apr—19
 Type—N mismatch combination            SN: 5047.2 / 06327       04—Apr—18 (No. 217—02683)                             Apr—19
 Reference Probe EX3DV4                 SN: 7349                 30—Dec—17 (No. EX3—7349_Dec17)                        Dec—18
 DAE4                                   SN: 601                  26—Oct—17 (No. DAE4—601_Oct17)                        Oct—18


 Secondary Standards                    ID #                      Check Date (in house)                                Scheduled Check
 Power meter EPM—442A                   SN: GB37480704            07—Oct—15 (in house check Oct—16)                    In house check: Oct—18
 Power sensor HP 8481A                  SN: US37292783            07—Oct—15 (in house check Oct—16)                    In house check: Oct—18
 Power sensor HP 8481A                  SN: MY41092317            07—Oct—15 (in house check Oct—16)                    In house check: Oct—18
 RF generator R&S SMT—06                SN: 100972                15—Jun—15 (in house check Oct—16)                    In house check: Oct—18
 Network Analyzer HP 8753E              SN: US37390585            18—Oct—01 (in house check Oct—17)                    in house check: Oct—18


                                        Name                                    Function                                Signature
 Calibrated by:                        Jeton Kastrati                           Laboratory Technician     C                               s



 Approved by:                          Katia Pokovic                            Technical Manager                 /%"


                                                                                                                       Issued: June 21, 2018
 This calibration certificate shall not be reproduced exceptin full without written approval of the laboratory.


Certificate No: D2600V2—1058_Jun18                                    Page 1 of 8


Calibration
      .     Laboratory of                                    en
                                                            #ar/                 S   Schweizerischer Kalibrierdienst
                                                            $                ~
Schmid & Partner                                           ib\g@                 c   Service suisse d‘étalonnage
  Engineering AG                                           T 7\\ 3                   Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                {'/,,///_\\\\‘\3     S   Swiss Calibration Service
                                                                frliluals®


Accredited by the Swiss Accreditation Service (SAS)                              Accreditation No.: SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreementfor the recognition of calibration certificates

Glossary:
TSL                         tissue simulating liquid
ConvF                       sensitivity in TSL / NORM x,y,z
N/A                         not applicable or not measured

Calibration is Performed According to the Following Standards:
   a) IEEE Std 1528—2013, "IEEE Recommended Practice for Determining the Peak Spatial—
      Averaged Specific Absorption Rate (SAR) in the Human Head from Wireless
      Communications Devices: Measurement Techniques", June 2013
   b) IEC 62209—1, "Measurement procedure for the assessment of Specific Absorption Rate
         (SAR) from hand—held and body—mounted devices used next to the ear (frequency range of
         300 MHz to 6 GHz)", July 2016
    c) IEC 62209—2, "Procedure to determine the Specific Absorption Rate (SAR) for wireless
       communication devices used in close proximity to the human body (frequency range of 30
       MHz to 6 GHz)", March 2010
    d) KDB 865664, "SAR Measurement Requirements for 100 MHz to 6 GHz"

Additional Documentation:
   e) DASY4/5 System Handbook

Methods Applied and Interpretation of Parameters:
   e Measurement Conditions: Further details are available from the Validation Report at the end
     of the certificate. All figures stated in the certificate are valid at the frequency indicated.
   e Antenna Parameters with TSL: The dipole is mounted with the spacer to position its feed
     point exactly below the center marking of the flat phantom section, with the arms oriented
         paralle! to the body axis.
    e    Feed Point Impedance and Return Loss: These parameters are measured with the dipole
         positioned under the liquid filled phantom. The impedance stated is transformed from the
         measurement at the SMA connector to the feed point. The Return Loss ensures low
         reflected power. No uncertainty required.
    e    Electrical Delay: One—way delay between the SMA connector and the antenna feed point.
         No uncertainty required.
    e    SAR measured: SAR measured at the stated antenna input power.
         SAR normalized: SAR as measured, normalized to an input power of 1 W at the antenna
         connector.
    e    SAR for nominal TSL parameters: The measured TSL parameters are used to calculate the
         nominal SAR result.
 The reported uncertainty of measurement is stated as the standard uncertainty of measurement
 multiplied by the coverage factor k=2, which for a normal distribution corresponds to a coverage
 probability of approximately 95%.




Certificate No: D2600V2—1058_Jun18                              Page 2 of 8


Measurement Conditions
   DASY system configuration, as far as not given on page 1.
     DASY Version                                              DASYS5                             V52.10.1
     Extrapolation                                   Advanced Extrapolation
     Phantom                                          Modular Flat Phantom

     Distance Dipole Center — TSL                              10 mm                             with Spacer
     Zoom Scan Resolution                              dx, dy, dz =5 mm

     Frequency                                         2600 MHz + 1 MHz



Head TSL parameters
   The following parameters and calculations were applied.
                                                               Temperature       Permittivity         Conductivity
     Nominal Head TSL parameters                                  22.0 °C           39.0               1.96 mho/m
     Measured Head TSL parameters                              (22.0 + 0.2) °C   37.4 +6 %          2.03 mho/m + 6 %

     Head TSL temperature change during test                      <0.5 °C

SAR result with Head TSL

     SAR averaged over 1 cm* (1 g) of Head TSL                  Condition
     SAR measured                                        250 mW input power                     14.3 Wikg
     SAR for nominal Head TSL parameters                     normalized to 1W         55.8 W/kg + 17.0 %(k=2)

     SAR averaged over 10 cm* (10 g) of Head TSL                 condition
     SAR measured                                        250 mW input power                  6.38 Wikg
     SAR for nominal Head TSL parameters                     normalized to 1W         25.1 Wikg + 16.5 % (k=2)


Body TSL parameters
   The following parameters and calculations were applied.
                                                               Temperature       Permittivity         Conductivity
     Nominal Body TSL parameters                                  22.0 °C           52.5               2.16 mho/m
     Measured Body TSL parameters                              (22.0 + 0.2) °C   51.8 +6 %          2.22 mho/m + 6 %

     Body TSL temperature change during test                      <0.5 °C            ————                    ~——

SAR result with Body TSL

     SAR averaged over 1 cm* (1 g) of Body TSL                  Condition
      SAR measured                                       250 mW input power                     13.8 W/kg
      SAR for nominal Body TSL parameters                    normalized to 1W         54.4 Wikg + 17.0 % (k=2)

      SAR averaged over 10 cm* (10 g) of Body TSL                condition
      SAR measured                                       250 mW input power                  6.15 W/kg
      SAR for nominal Body TSL parameters                    normalized to 1W         24.4 Wikg + 16.5 % (k=2)



Certificate No: D2600V2—1058_Jun18                    Page 3 of 8


Appendix (Additional assessments outside the scope of SCS 0108)

Antenna Parameters with Head TSL

      Impedance, transformed to feed point                                           49.7 Q — 7.5 jQ

      Return Loss                                                                       —22.4 dB



Antenna Parameters with Body TSL

      Impedance, transformed to feed point                                           45.3 Q — 6.9 jQ

      Return Loss                                                                       —21.1 dB




General Antenna Parameters and Design

      Electrical Delay (one direction)                                                   1.149 ns


After long term use with 100W radiated power, only a slight warming of the dipole near the feedpoint can be measured.

The dipole is made of standard semirigid coaxial cable. The center conductor of the feeding line is directly connected to the
second arm of the dipole. The antenna is therefore short—circuited for DC—signals. On some of the dipoles, small end caps
are added to the dipole arms in order to improve matching when loaded according to the position as explained in the
"Measurement Conditions" paragraph. The SAR data are not affected by this change. The overall dipole length is still
according to the Standard.
No excessive force must be applied to the dipole arms, because they might bend or the soldered connections near the
feedpoint may be damaged.


Additional EUT Data

      Manufactured by                                                                    SPEAG
      Manufactured on                                                                August 14, 2012




Certificate No: D2600V2—1058_Jun18                       Page 4 of 8


DASY5 Validation Report for Head TSL

                                                                                     Date: 19.06.2018

Test Laboratory: SPEAG, Zurich, Switzerland

DUT: Dipole 2600 MHz; Type: D2600V2; Serial: D2600V2 — SN:1058

Communication System: UID 0 — CW; Frequency: 2600 MHz
Medium parameters used: f = 2600 MHz; 0 = 2.03 S/m:; &, = 37.4; p = 1000 kg/m3
Phantom section: Flat Section
Measurement Standard: DASYS5 (IEEE/IEC/ANSI C63.19—2011)

DASY52 Configuration:

   e     Probe: EX3DV4 — SN7349; ConvF(7.7, 7.7, 7.7) @ 2600 MHz; Calibrated: 30.12.2017

         Sensor—Surface: 1.4mm (Mechanical Surface Detection)

         Electronics: DAE4 $n601; Calibrated: 26.10.2017

         Phantom: Flat Phantom 5.0 (front); Type: QD 000 P50 AA; Serial: 1001

         DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Dipole Calibration for Head Tissue/Pin=250 mW, d=10mm/Zoom Scan (7x7x7)/Cube 0:
Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 117.8 V/m; Power Drift =—0.05 dB
Peak SAR (extrapolated) = 28.5 W/kg
SAR(I g) = 14.3 W/kg; SAR(10 g) = 6.38 W/kg
Maximum value of SAR (measured) = 23.8 W/kg


        dB
       F 0


         —4.00


         —8.00


         —12.00


         —16.00


         —20.00
                   0 dB = 23.8 W/kg = 13.77 dBW/kg




Certificate No: D2600V2—1058_Jun18               Page 5 of 8


Impedance Measurement Plot for Head TSL




                                                                   19 Jun 2018    14106147
         CHI) sii     1 U Fs          1149.689 0   —7.5430a   81153 pF           2 600.000 000 MHz




         fAvq
         16


         H1d


          CH2




         Ca




         Ay
         16°

         H1d

                    START 2 400.000 000 MHz                              STOP 2 ©00.000 000 MHz




Certificate No: D2600V2—1058_Jun18                   Page 6 of 8


DASY5 Validation Report for Body TSL

                                                                                     Date: 19.06.2018
Test Laboratory: SPEAG, Zurich, Switzerland

DUT: Dipole 2600 MHz; Type: D2600V2; Serial: D2600V2 — SN:1058

Communication System: UID 0 — CW; Frequency: 2600 MHz
Medium parameters used: f = 2600 MHz; 0 = 2.22 $/m; & = 51.8; p = 1000 kg/m‘
Phantom section: Flat Section
Measurement Standard: DASYS5 (IEEE/IEC/ANSI €63.19—2011)

DASY52 Configuration:

   e     Probe: EX3DV4 — SN7349; ConvF(7.81, 7.81, 7.81) @ 2600 MHz; Calibrated: 30.12.2017

   e     Sensor—Surface: 1.4mm (Mechanical Surface Detection)

         Electronics: DAE4 Sn601; Calibrated: 26.10.2017

         Phantom: Flat Phantom 5.0 (back); Type: QD 000 P50 AA; Serial: 1002

         DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Dipole Calibration for Body Tissue/Pin=250 mW, d=10mm/Zoom Scan (7x7x7)/Cube 0:
Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 107.8 V/m; Power Drift = —0.02 dB
Peak SAR (extrapolated) = 28.0 W/kg
SAR(I g) = 13.8 W/kg; SAR(10 g) = 6.15 W/kg
Maximum value of SAR (measured) =23.1 W/kg


        dB
       ! 0


       —| —5.00


         —10.00


         —15.00


         —20.00


         —25.00
                   0 dB = 23.1 W/kg = 13.64 dBW/kg




Certificate No: D2600V2—1058_Jun18              Page 7 of 8


Impedance Measurement Plot for Body TSL




                                                                      19 Jun 2018    10:09:42
          CHI) sii       4 uors          41 45.258 a   —£.9160 0 ©.9510 pF          2 e00.000 ooo MHz
                                                        T

          Del

          Ca




          fivg
          16


          H1d

          CH2    S11




          Ca




          Av
          16°

          H1d

                       START 2 400.000 000 MHz                               STOP 2 800.000 000 MHz




Certificate No: D2600V2—1058_Jun18                      Page 8 of 8


Calibration Laboratory cf                                         S\\\\‘@’fi,”}                             S       Schweizerischer Kalibrierdienst
Schmid & Partner                                                 in                                        C       Service suisse d‘étalonnage
  Engineering AG                                                                                                   Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                       y         yX                            S       Swiss Calibration Service
                                                                      Alululst



Accredited by the Swiss Accreditation Service (SAS)                                                         Accreditation No.: SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Client       BV ADT Korea (Auden)                                                              Certificate No: DBGHzV2—1019_Mari8


CALIBRATION CERTIFICATE
 Object                               D5GHzV2 — SN:1019


 Calibration procedure(s)             QA CAL—22.v3
                                      Calibration procedure for dipole validation kits between 3—6 GHz



 Calibration date:                    March 22, 2018


 This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (S1).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 + 3)°C and humidity < 70%.


 Calibration Equipment used (M&TE critical for calibration)


 Primary Standards                      ID #                      Cal Date (Certificate No.)                            Scheduled Calibration
 Power meter NRP                        SN: 104778                04—Apr—17 (No. 217—02521/02522)                       Apr—18
 Power sensor NRP—Z91                   SN:    103244             04—Apr—17 (No. 217—02521)                             Apr—18
 Power sensor NRP—Z91                   SN:    103245             04—Apr—17 (No. 217—02522)                             Apr—18
 Reference 20 dB Attenuator             SN:    5058 (20k)         07—Apr—17 (No. 217—02528)                             Apr—18
 Type—N mismatch combination            SN:    5047.2 / 06327     07—Apr—17 (No. 217—02529)                             Apr—18
 Reference Probe EX3DV4                 SN:    3508               30—Dec—17 (No. EX3—3503_Dec17)                        Dec—18
 DAE4                                   SN:    601                26—Oct—17 (No. DAE4—601_Oct17)                        Oct—18


 Secondary Standards                    ID #                      Check Date (in house)                                 Scheduled Check
 Power meter EPM—442A                   SN:    GB37480704         07—Oct—15 (in   house check Oct—16)                   In   house   check:   Oct—18
 Power sensor HP 8481A                  SN:    US37292783         07—Oct—15 (in   house check Oct—16)                   In   house   check:   Oct—18
 Power sensor HP 8481A                  SN:    MY41092317         07—Oct—15 (in   house check Oct—16)                   In   house   check:   Oct—18
 RF generator R&S SMT—O6                SN:    100972             15—Jun—15 (in   house check Oct—16)                   In   house   check:   Oct—18
 Network Analyzer HP 8753E              SN: US37390585            18—Oct—01 (in   house check Oct—17)                   In   house   check:   Oct—18


                                        Name                                     Function                                Signature
 Calibrated by:                         Jeton Kastrati                           Laboratory Technician     QT—-;Z                        (%


 Approved by:                           Katia Pokovic                            Technical Manager



                                                                                                                        Issued: March 26, 2018
 This calibration certificate shall not be reproduced except in full without written approval of the laboratory.


Certificate No: D5GHzV2—1019_Mar18                                    Page 1 of 15



Document Created: 2018-10-23 14:44:55
Document Modified: 2018-10-23 14:44:55