MPE Revised

FCC ID: HD5-CCBHBF01A

RF Exposure Info

Download: PDF
FCCID_4280793

            RF Exposure Evaluation Declaration

                    Product Name : Charger Cradle
                    Model No.              : CCB-H-010BT-BF
                    FCC ID                 : HD5-CCBHBF01A




            Applicant : HONEYWELL INTERNATIONAL INC
                              Honeywell Safety and Productivity Solutions
            Address : 9680 OLD BAILES RD
                              FORT MILL SC 29707-7539




               Date of Receipt : Mar. 15, 2019
               Test Date                : Mar. 16, 2019 ~ Apr. 12, 2019
               Issued Date              : May. 16, 2019
               Report No.               : 1952117R-RF-US-P20V01
               Report Version : V1.0



The test results relate only to the samples tested.
The test results shown in the test report are traceable to the national/international standard through the
calibration of the equipment and evaluated measurement uncertainty herein.
This report must not be used to claim product endorsement by A2LA or any agency of the government.
The test report shall not be reproduced without the written approval of DEKRA Testing & Certification (Suzhou)
Co., Ltd.


Report No: 1952117R-RF-US-P20V01



                  Tes t R e p o r t C e r t i f i c a t i o n
                                                      Issued Date : May. 16, 2019
                                                        Report No. : 1952117R-RF-US-P20V01




   Product Name            : Charger Cradle
   Applicant               : HONEYWELL INTERNATIONAL INC
                             Honeywell Safety and Productivity Solutions
   Address                 : 9680 OLD BAILES RD
                             FORT MILL SC 29707-7539
   Manufacturer            : 1、HONEYWELL INTERNATIONAL INC
                             Honeywell Safety and Productivity Solutions
                             2、Metro(Suzhou)Technologies Co.,Ltd
   Address                 : 1、9680  OLD BAILES RD
                             FORT MILL SC 29707-7539
                             2、No.221 Xinghai street China-Singapore Suzhou Industrial
                             Park
   Model No.               : CCB-H-010BT-BF
   FCC ID                  : HD5-CCBHBF01A
   Brand name             : Honeywell
   EUT Voltage             : DC 5V
   Test Voltage            : AC120V/60Hz
   Applicable Standard     : KDB 447498D01V06
                               FCC Part1.1310
   Test Result             : Complied
   Performed Location      : DEKRA Testing & Certification (Suzhou) Co., Ltd.
                               No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006,
                               Jiangsu, China
                               TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098
                               FCC Designation Number: CN1199
       Documented By       :


                                                ( Adm. Specialist: Kitty Li )
        Reviewed By        :


                                          (Senior Project Manager: Frank He )
         Approved By       :



                                         (Engineering Supervisor: Jack Zhang)



                                       Page: 2 of 5


 Report No: 1952117R-RF-US-P20V01


1. RF Exposure Evaluation

1.1. Limits
     According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate
     the environment impact of human exposure to radio frequency (RF) radiation as specified in
     1.1307(b)
     LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
                               Electric               Magnetic
                                                                    Power             Average
          Frequency            Field                  Field
                                                                    Density           Time
          Range (MHz)          Strength               Strength
                                                                    (mW/cm2)          (Minutes)
                               (V/m)                  (A/m)
          (A) Limits for Occupational/ Control Exposures
          300-1500             --                     --            F/300             6
          1500-100,000         --                     --            5                 6
          (B) Limits for General Population/ Uncontrolled Exposures
          300-1500             --                     --            F/1500            6
          1500-100,000         --                     --            1                 30
     F= Frequency in MHz


     Friis Formula
     Friis transmission formula: Pd = (Pout*G)/(4*pi*r2)


     Where
                                       2
     Pd = power density in mW/ cm
     Pout = output power to antenna in mW
     G = gain of antenna in linear scale
     Pi = 3.1416
     R = distance between observation point and center of the radiator in cm

                                           2
     Pd is the limit of MPE, 1 mW/cm . If we know the maximum gain of the antenna and the total
     power input to the antenna, through the calculation, we will know the distance r where the
     MPE limit is reached.




                                               Page: 3 of 5


 Report No: 1952117R-RF-US-P20V01


1.2. Test Procedure

     Software provided by client enabled the EUT to transmit and receive data at lowest, middle
     and highest channel individually.
     The temperature and related humidity: 18℃and 78% RH.


1.3. Test Result of RF Exposure Evaluation

Product             : Charger Cradle
Test Item           : RF Exposure Evaluation
Test Site           : AC-6


           Antenna Information:
Antenna manufacturer         N/A
Antenna Delivery                   1*TX+1*RX                 2*TX+2*RX           3*TX+3*RX
Antenna technology                 SISO
                                                    Basic
                                   MIMO             CDD
                                                    Beam-forming
Antenna Type                       External         Dipole
                                                    PIFA
                                                    PCB
                                                    Ceramic Chip Antenna
                                   Internal
                                                    Monopole antenna
                                                    Stamping Antenna
                                                    Metal plate type F antenna
Antenna Gain                 1.8dBi




                                              Page: 4 of 5


 Report No: 1952117R-RF-US-P20V01




           Power Density:


                                                          Limit of Power   Power Density
                       Frequency Band           EIRP
    Test Mode                                                Density       at R = 20 cm
                             (MHz)              (dBm)
                                                           S(mW/cm2)        (mW/cm2)
            BT          2400 ~ 2483.5           0.21            1             0.0001
Note:
                                            2
The maximum power density is 0.0073mW/cm for Charger Cradle without any other radio
equipment.




                                          The End




                                        Page: 5 of 5



Document Created: 2019-05-26 03:02:56
Document Modified: 2019-05-26 03:02:56