    Project #0000163636                                   Report # 31951956.001                                                      Page 1 of 26
        Report Date:4/22/19                                               Rev. 0




                        Electromagnetic Compatibility
                                Test Report
                                                     Prepared in accordance with

                                 FCC Part 15 Subpart B:2018
                                                                           On

                                                       April 22, 2019
                                                                  Prepared for:

                The Chamberlain Group Incorporated
                        300 Windsor Drive
                       Oak Brook, IL 60523

                                            FCC ID: HBW8522
                                            IC ID: 2666A-8522
                                                                  Prepared by:

                               TUV Rheinland of North America, Inc.
                                    1279 Quarry Lane, Ste. A
                                  Pleasanton, CA 94566 U.S.A.


The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not
referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not
constitute authorization for the use of any TÜV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or
endorsement


    Project #0000163636                                   Report # 31951956.001                                                      Page 2 of 26
        Report Date:4/22/19                                               Rev. 0

                                                                    Revisions
  Revision                    Date                                         Reason for Change                                             Author
    No.
       0                    4/22/19                                         Original Document                                            AA/JS




Note: Latest revision report will replace all previous reports.




The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not
referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not
constitute authorization for the use of any TÜV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or
endorsement


    Project #0000163636                                   Report # 31951956.001                                                      Page 3 of 26
         Report Date:4/22/19                                              Rev. 0


                                          ATTESTATION OF TEST RESULTS
                           The Chamberlain Group Incorporated,                                    Tel. (630) 279-3600
                   Client: 300 Windsor Drive.
                           Oak Brook IL 60523

          Model Name: MyQ B-Hub                                                           Serial Number: N/A

     Model Numbers: MyQ B-Hub                                                              Date(s) Tested: 3/19/2019

                                 TUV Rheinland of North America
                                 1279 Quarry Lane, Ste. A
         Test Location:
                                 Pleasanton, CA 94566 U.S.A.
                                 Tel. (925) 249-9123



                               Emissions:            FCC Part 15 Subpart B:2018

  Test Specifications:


                               Immunity:            N/A



            Test Result:            The above product was found to be Compliant to the above test standard(s)

  Prepared by:                                                                     Reviewed by:




  04/22/2019 Josie Sabado                                                          04/22/2019 David Spencer
  Date                     Name                     Signature                      Date                   Name                    Signature
         Other aspects: None
                                                                 PLEASANTON


                                                                               INDUSTRY CANADA
                                                                                    2932M-1
          US1131                        Testing Cert #3331.02                                                                  1097 (A-0268)




The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not
referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not
constitute authorization for the use of any TÜV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or
endorsement


    Project #0000163636                                         Report # 31951956.001                                                                Page 4 of 26
          Report Date:4/22/19                                                     Rev. 0

TABLE of CONTENTS
1     GENERAL INFORMATION ......................................................................................................................... 5
    1.1      SCOPE ......................................................................................................................................................... 5
    1.2      PURPOSE ..................................................................................................................................................... 5
    1.3      SUMMARY OF TEST RESULTS ..................................................................................................................... 6
LABORATORY INFORMATION ........................................................................................................................ 7
    1.4      ACCREDITATIONS & ENDORSEMENTS ........................................................................................................ 7
    1.5      TEST FACILITIES AND EMC SOFTWARE ..................................................................................................... 8
    1.6      MEASUREMENT UNCERTAINTY .................................................................................................................. 9
    1.7      CALIBRATION TRACEABILITY .................................................................................................................. 10
    1.8      MEASUREMENT EQUIPMENT USED .......................................................................................................... 10
2     PRODUCT INFORMATION ....................................................................................................................... 11
    2.1      PRODUCT DESCRIPTION............................................................................................................................ 11
    2.2      EQUIPMENT MODIFICATIONS ................................................................................................................... 11
    2.3      TEST PLAN ................................................................................................................................................ 11
3     EMISSIONS.................................................................................................................................................... 14
    3.1      RADIATED EMISSIONS .............................................................................................................................. 14
4     TEST PLAN .................................................................................................................................................... 21
    4.1      GENERAL INFORMATION .......................................................................................................................... 21
    4.2      EUT DESIGNATION................................................................................................................................... 21
    4.3      EUT DESCRIPTION ................................................................................................................................... 21
    4.4      EQUIPMENT UNDER TEST (EUT) DESCRIPTION ....................................................................................... 22
    4.5      PRODUCT ENVIRONMENT(S) .................................................................................................................... 22
    4.6      APPLICABLE DOCUMENTS ........................................................................................................................ 22
    4.7      EUT CLOCK/OSCILLATOR FREQUENCIES ................................................................................................ 23
    4.8      EUT TEST PROGRAM................................................................................................................................ 23
    4.9      EUT MODES OF OPERATION .................................................................................................................... 23
    4.10     MONITORING OF EUT DURING TESTING .................................................................................................. 23
    4.11     EUT CONFIGURATION .............................................................................................................................. 24
    4.12     EMISSIONS ................................................................................................................................................ 25




The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not
referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not
constitute authorization for the use of any TÜV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or
endorsement


    Project #0000163636                                   Report # 31951956.001                                                      Page 5 of 26
        Report Date:4/22/19                                               Rev. 0




1 General Information
           1.1        Scope
           This report is intended to document the status of conformance with the listed standards based on the results
           of testing performed on March 19, 2019 on the Chamberlain Remote Control, Model No MyQ B-Hub,
           manufactured by The Chamberlain Group Incorporated. This report only applies to the specific samples
           tested under the stated test conditions. It is the responsibility of the manufacturer to assure that additional
           production units of this model are manufactured with identical or EMI equivalent electrical and mechanical
           components. This report is further intended to document changes and modifications to the EUT throughout
           its life cycle. All documentation will be included as a supplement.

           1.2        Purpose
           Testing was performed to evaluate the EMC performance of the EUT (Equipment Under Test) in
           accordance with the applicable requirements, procedures, and criteria defined in the application of
           regulations and application of standards listed in this report.




The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not
referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not
constitute authorization for the use of any TÜV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or
endorsement


    Project #0000163636                                   Report # 31951956.001                                                      Page 6 of 26
        Report Date:4/22/19                                               Rev. 0



            1.3        Summary of Test Results

                       The Chamberlain Group Incorporate,
             Applicant 300 Windsor Drive.
                       Oak Brook IL 60523

               Contact Adrian Perry
                     Tel. (630) 279-3600
                  E-mail adrian.perry@chamberlain.com
          Description Smart Garage Hub Bluetooth
        Model Name MyQ B-Hub
     Model Number MyQ B-Hub
      Serial Number 001D9309-1
         Input Power 2.0 to 3.8 VDC (3.3 VDC Nominal)
          Test Date(s) 3/19/19


        Standards                   Description               Severity Level or Limit                Criteria                 Test Result



 FCC Part 15                         Radiated                           Class B
                                                                                                       Limit                    Complies
 Subpart B:2018                      Emissions                         30-18GHz



 FCC Part 15 Subpart                 Conducted                         Class B
                                                                                                       Limit                        N/A
 B:2018                              Emissions                    150 kHz - 30 MHz




The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not
referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not
constitute authorization for the use of any TÜV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or
endorsement


    Project #0000163636                                   Report # 31951956.001                                                      Page 7 of 26
        Report Date:4/22/19                                               Rev. 0

Laboratory Information
           1.4        Accreditations & Endorsements

           1.4.1       US Federal Communications Commission
                      TUV Rheinland of North America EMC test facilities located at 1279 Quarry Lane, Ste. A,
                     Pleasanton, CA, 94566, and 5015 Brandin Ct, Fremont, CA 94538, are recognized by the
                     Commission for performing testing services for the general public on a fee basis. These
           laboratory test facilities have been fully described in reports submitted to and accepted by the FCC. The
           laboratory Scopes of Accreditation include Title 47 CFR Parts 15, 18 and 90. The accreditations are
           updated every three years.



           1.4.2       A2LA
                                               TUV Rheinland of North America EMC test facilities are accredited by the
                                               American Association for Laboratory Accreditation (A2LA). The laboratories
                                               have been assessed and accredited by A2LA in accordance with ISO Standard
                                               17025:2005 (Testing Certificate #3331.02). The Scope of Laboratory
                                               Accreditation includes emission and immunity testing. The accreditations are
           updated annually.

           1.4.3       Industry Canada
                                      The Pleasanton 5-meter Semi-Anechoic Chamber, Registration No. 2932M-1,
                                      has been accepted by Industry Canada to perform testing to 3 and 5 meters
           based on the test procedures described in ANSI C63.4-2009.

           1.4.4       Japan – VCCI
                              The Voluntary Control Council for Interference by Information Technology Equipment
                              (VCCI) is a group that consists of Information Technology Equipment (ITE)
                              manufacturers and EMC test laboratories. The purpose of the Council is to take voluntary
                              control measures against electromagnetic interference from Information Technology
           Equipment, and thereby contribute to the development of a socially beneficial and responsible state of
           affairs in the realm of Information Technology Equipment in Japan. TUV Rheinland of North America
           EMC test facilities located at 1279 Quarry Lane, Ste. A, Pleasanton, CA, 94566, and 5015 Brandin Ct,
           Fremont, CA 94538, have been assessed and approved in accordance with the Regulations for Voluntary
           Control Measures.
           VCCI Registration No. for Pleasanton: A-0268
           VCCI Registration No. for Fremont: A-0268




The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not
referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not
constitute authorization for the use of any TÜV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or
endorsement


    Project #0000163636                                   Report # 31951956.001                                                      Page 8 of 26
        Report Date:4/22/19                                               Rev. 0

           1.5        Test Facilities and EMC Software
           Test facilities are located at 1279 Quarry Lane, Ste. A, Pleasanton, California 94566, U.S.A. and 5015
           Brandin Ct. Fremont CA 94538 USA (Fremont is the Pleasanton Annex).

           1.5.1      Emission Test Facility
           The Semi-Anechoic Chambers and AC Line Conducted measurement facilities used to collect radiated and
           conducted emissions data have been constructed in accordance with ANSI C63.7:1992. The Fremont 10
           meter semi-anechoic chamber has been measured in accordance with and verified to comply with the
           theoretical volumetric normalized site attenuation of ANSI C63.4:2014 and SVSWR requirements of
           CISPR 16-1-4 Consol. Ed. 3.0 (2010-04), at test distances of 3 and 10 meters. This site has been described
           in reports dated November 1st, 2006, submitted to the FCC, and accepted by letter dated November 28,
           2006. The site is listed with the FCC and accredited by A2LA (Testing Certificate #3331.02). The
           Pleasanton 5 meter semi-anechoic chamber has been verified to comply with the theoretical volumetric
           normalized site attenuation of ANSI C63.4:2009 and SVSWR requirements of CISPR 16-1-4 Consol. Ed.
           3.0 (2010-04) at a test distance of 3 meters. This site has been described in reports dated November 1st,
           2006, submitted to the FCC, and accepted by letter dated November 28, 2006. The site is listed with the
           FCC and accredited by A2LA (Testing Certificate #3331.02).

            1.5.2      EMC Software - Pleasanton
                   Manufacturer                        Name                           Version                         Test Type
                                                                                                                Radiated & Conducted
                   ETS-Lindgren                         TILE                  3.4.K.14 @ 4.0.A.5
                                                                                                                Emissions
                                                                                                                Radiated & Conducted
                       EMISoft                        Vasona                             5.0
                                                                                                                Emissions
                                                                                                                Radiated & Conducted
                        Agilent                   Agilent MXE                         A.11.02
                                                                                                                Emissions
                                                                                                                Radiated & Conducted
                   ETS-Lindgren                         TILE                          3.4.K.14
                                                                                                                Immunity
                 Thermo Electron -                                                                              EFT/Surge/Voltage
                                                    CEWare32                             4.00
                     Keytek                                                                                     Dips & Interrupt
                     Voltech                       IEC61000-3                      1.21.07RC2                   Harmonic & Flicker




The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not
referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not
constitute authorization for the use of any TÜV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or
endorsement


    Project #0000163636                                   Report # 31951956.001                                                      Page 9 of 26
        Report Date:4/22/19                                               Rev. 0

           1.6        Measurement Uncertainty
           Two types of measurement uncertainty are expressed in this report, per ISO Guide To The Expression Of
           Uncertainty In Measurement, 1st Edition, 1995.
           The Combined Standard Uncertainty is the standard uncertainty of the result of a measurement when that
           result is obtained from the values of a number of other quantities, equal to the positive square root of a sum
           of terms, the terms being the variances or co-variances of these other quantities weighted according to how
           the measurement result varies with changes in these quantities. The term standard uncertainty is the result
           of a measurement expressed as a standard deviation.
           The Expanded Uncertainty defines an interval about the result of a measurement that may be expected to
           encompass a large fraction of the distribution of values that could reasonably be attributed to the
           measurement and the fraction may be viewed as the coverage probability or level of confidence of the
           interval.

           1.6.1      Sample Calculation – radiated & conducted emissions
           The field strength is calculated by subtracting the Amplifier Gain and adding the Cable Loss and Antenna
           Correction Factor to the measured reading. The basic equation is as follows:
                                            Field Strength (dBV/m) = RAW - AMP + CBL + ACF
                                           Where: RAW = Measured level before correction (dBV)
                                                               AMP = Amplifier Gain (dB)
                                                                  CBL = Cable Loss (dB)
                                                      ACF = Antenna Correction Factor (dB/m)
                                                                                      dBV / m

                                                                      V/m = 10          20


                                               Sample radiated emissions calculation @ 30 MHz
                 Measurement +Antenna Factor–Amplifier Gain+Cable loss=Radiated Emissions (dBuV/m)
                                            25 dBuV/m + 17.5 dB – 20 dB + 1.0 dB = 23.5 dBuV/m




The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not
referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not
constitute authorization for the use of any TÜV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or
endorsement


    Project #0000163636                                   Report # 31951956.001                                                    Page 10 of 26
        Report Date:4/22/19                                               Rev. 0




            1.6.2      Measurement Uncertainty Emissions
              Per CISPR 16-4-2                                                    Ulab                                              Ucispr
              Radiated Disturbance @ 3 meters
              30 – 1,000 MHz                                                    2.26 dB                                           4.52 dB
              1 – 6 GHz                                                         2.12 dB                                           4.25 dB
              6 – 18 GHz                                                        2.47 dB                                           4.93 dB
              Conducted Disturbance @ Mains Terminals
              150 kHz – 30 MHz                                                  1.09 dB                                           2.18 dB

           1.7        Calibration Traceability
           All measurement instrumentation is traceable to the National Institute of Standards and Technology (NIST).
           Measurement method complies with ANSI/NCSL Z540-1-1994 and ISO Standard 17025:2005. Equipment
           calibration records are kept on file at the test facility.

           1.8        Measurement Equipment Used
                                                                                                            Last Cal         Next Cal
         Equipment                Manufacturer                  Model #                Serial/Inst #                                            Test
                                                                                                            mm/dd/yy         mm/dd/yy

       Antenna, Bilog             Sunol Sciences                   JB3                    A102606           11/20/2017       11/20/2019          RE
        Antenna,Horn              Sunol Sciences                  3115                    A040806           05/16/2018       05/16/2019          RE
          Amplifier                    Miteq               TTA1800-30-HG                  2020728           01/15/2019       01/15/2020          RE
                                      Sonoma
          Amplifier                                               310N                    213221            01/14/2019       01/14/2020          RE
                                     Instaments
           Receiver              Rohde & Schwarz                  ESI40                  832427/002         01/22/2019       01/22/2020          RE
Note: CE=Conducted Emissions, CI=Conducted Immunity, DP=Disturbance Power, EFT=Electrical Fast Transients, ESD=Electrostatic
      Discharge, FLI=Flicker, HAR=Harmonics, MF=Magnetic Field Immunity, NCR=No Calibration Required, RE=Radiated Emissions,
      RI=Radiated Immunity, SI=Surge Immunity, VDSI=Voltage Dips and Short Interruptions




The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not
referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not
constitute authorization for the use of any TÜV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or
endorsement


    Project #0000163636                                   Report # 31951956.001                                                    Page 11 of 26
        Report Date:4/22/19                                               Rev. 0

2     Product Information
           2.1        Product Description
           See Section 6.4.



           2.2        Equipment Modifications
           No modifications were needed to bring product into compliance.

           2.3        Test Plan
           The EUT product information, test configuration, mode of operation, test types, test procedures, test levels,
           pass/failure criteria, in this report were carried out per the product test plan located in Appendix A of this
           report.




The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not
referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not
constitute authorization for the use of any TÜV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or
endorsement


    Project #0000163636                                   Report # 31951956.001                                                    Page 12 of 26
        Report Date:4/22/19                                               Rev. 0




                                                      Figure 1 - External Photo of EUT




The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not
referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not
constitute authorization for the use of any TÜV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or
endorsement


    Project #0000163636                                   Report # 31951956.001                                                    Page 13 of 26
        Report Date:4/22/19                                               Rev. 0




                                                       Figure 2 - Internal Photo of EUT




The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not
referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not
constitute authorization for the use of any TÜV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or
endorsement


    Project #0000163636                                   Report # 31951956.001                                                    Page 14 of 26
        Report Date:4/22/19                                               Rev. 0

3 Emissions
           3.1     Radiated Emissions
           This test measures the electromagnetic levels of spurious signals generated by the EUT that radiated from
           the EUT and may affect the performance of other nearby electronic equipment.

           3.1.1      Overview of Test
             Results                      Compliant (as tested per this report)                     Test Date(s)             March 19, 2019
             Standard
                                          FCC Part 15 Subpart B:2018


             Model Number                 MyQ B-Hub                                                 Serial #
             Configuration                Unintentional Radiated Emissions
             Test Setup                   Tested in the 5-meter chamber, placed on table: see test plan for details.
             EUT Powered By               120V Block Adapter
             Environmental                March 19, 2019               Temp        26.1º C      Humidity          36.8%       Pressure        28.65 mbar
             Conditions
             Frequency Range              30 MHz to 18 GHz
             Perf. Criteria               Class B                                  Perf. Verification               Readings under limit
             Mod. to EUT                  None                                     Test Performed By                Abraham Avalos

           3.1.2      Test Procedure
           Unintentional Radiated emissions tests were performed using the procedures of ANSI C63.4:2014
           including methods for signal maximizations and EUT configuration. The photos included with the report
           show the EUT in its maximized configuration.
           The frequency range from 30 MHz to 18 GHz was investigated for radiated emissions.

           3.1.3      Deviations
           There were no deviations from the test methodology listed in the test plan for the radiated emission test.

           3.1.4      Final Test
           All final radiated emissions measurements were below the specification limits.




The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not
referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not
constitute authorization for the use of any TÜV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or
endorsement


    Project #0000163636                                   Report # 31951956.001                                                    Page 15 of 26
        Report Date:4/22/19                                               Rev. 0

            3.1.5      Plots
   NOTES:
                                                         Radiated Emissions Full Scan
                                                            30 MHz – 1000 MHz
                                                                  Vertical / Horizontal

       Frequency         Quasi           MaxPeak        Limit           Margin       Meas.        Bandwidth           Height        Pol       Azimuth
         (MHz)                                                           (dB)                       (kHz)              (cm)                    (deg)
                          Peak           (dBµV/m) (dBµV/m)                            Time
                         (dBµV/m)                                                     (ms)

          41.450000             31.99             ---        40.00            8.01        2.0          120.000             100.0 V                 334.0

          41.650000             32.03             ---        40.00            7.97        2.0          120.000             100.0 V                 330.0

          41.700000             32.06             ---        40.00            7.94        2.0          120.000             100.0 V                 325.0

          42.000000             31.13             ---        40.00            8.87        2.0          120.000             100.0 V                 328.0

          74.800000             32.05             ---        40.00            7.95        2.0          120.000             100.0 V                    0.0




The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not
referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not
constitute authorization for the use of any TÜV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or
endorsement


    Project #0000163636                                   Report # 31951956.001                                                    Page 16 of 26
        Report Date:4/22/19                                               Rev. 0

   NOTES:
                                                         Radiated Emissions Full Scan
                                                              1 GHz – 18 GHz
                                                                  Vertical / Horizontal



       Frequency          MaxPeak        Average        Limit         Margin        Meas.       Bandwidth           Height        Pol       Azimuth
         (MHz)                                                         (dB)                       (kHz)              (cm)                    (deg)
                         (dBµV/m)        (dBµV/m)       (dBµV/m)                    Time
                                                                                     (ms)

       1049.500000                 ---        15.60         54.00         38.40         2.0         1000.000            400.0 H                  198.0

       2411.500000              29.49             ---       74.00         44.51         2.0         1000.000            157.0 H                  318.0

       3980.500000                 ---        24.20         54.00         29.80         2.0         1000.000            254.0 V                    51.0

       4564.000000              35.56             ---       74.00         38.44         2.0         1000.000            339.0 V                  230.0

      10201.500000              40.69             ---       74.00         33.31         2.0         1000.000            214.0 V                  104.0

      17932.500000                 ---        39.03         54.00         14.97         2.0         1000.000            159.0 V                  114.0




The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not
referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not
constitute authorization for the use of any TÜV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or
endorsement


    Project #0000163636                                   Report # 31951956.001                                                    Page 17 of 26
        Report Date:4/22/19                                               Rev. 0

           3.1.6      Photos




                                 Figure 3 - Radiated Emissions Test Setup 30 - 1000 MHz - Front




The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not
referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not
constitute authorization for the use of any TÜV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or
endorsement


    Project #0000163636                                   Report # 31951956.001                                                    Page 18 of 26
        Report Date:4/22/19                                               Rev. 0




                                 Figure 4 - Radiated Emissions Test Setup 30 - 1000 MHz - Back




The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not
referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not
constitute authorization for the use of any TÜV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or
endorsement


    Project #0000163636                                   Report # 31951956.001                                                    Page 19 of 26
        Report Date:4/22/19                                               Rev. 0




                                 Figure 5 - Radiated Emissions Test Setup 1 GHz – 18GHz Front




The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not
referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not
constitute authorization for the use of any TÜV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or
endorsement


    Project #0000163636                                   Report # 31951956.001                                                    Page 20 of 26
        Report Date:4/22/19                                               Rev. 0




                                  Figure 6 - Radiated Emissions Test Setup 1 GHz – 18GHz Back




The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not
referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not
constitute authorization for the use of any TÜV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or
endorsement


    Project #0000163636                                   Report # 31951956.001                                                    Page 21 of 26
        Report Date:4/22/19                                               Rev. 0

                                                                  Appendix A

4     Test Plan
           This test report is intended to follow this test plan outlined here in unless otherwise stated in this here report.
           The following test plan will give details on product information, standards to be used, test set ups and refer
           to TUV test procedures. The test procedures will give the steps to be taken when performing the stated test.
           The product information below came via client, product manual, product itself and or the internet.

           4.1        General Information
                  Client                The Chamberlain Group Incorporated

                                        The Chamberlain Group Incorporated
                  Address               300 Windsor Drive
                                        Oak Brook IL 60523


                  Contact               Adrian Perry
                  Person
                  Telephone             (630) 279-3600
                  e-mail                adrian.perry@chamberlain.com



           4.2        EUT Designation
                  Model Name                   MyQ B-Hub
                  Model Number(s)              MyQ B-Hub



           4.3        EUT Description
                  Garage Remote Control




The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not
referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not
constitute authorization for the use of any TÜV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or
endorsement


    Project #0000163636                                   Report # 31951956.001                                                    Page 22 of 26
        Report Date:4/22/19                                               Rev. 0

           4.4        Equipment Under Test (EUT) Description
The Chamberlain MyQ B-Hub is a remote control.



           4.5        Product Environment(s)
                  ☒         Domestic/Residential                                    ☐         Hospital
                  ☐         Light Industrial/Commercial                             ☐         Small Clinic
                  ☐         Industrial                                              ☐         Doctor’s office
                            Telecommunications Center                                         Other than Telecommunications
                  ☐                                                                 ☐
                                                                                              Center
                  ☐         Other
           *Check all that apply


           4.6        Applicable Documents

                               Standards                                                           Description

          FCC Part 15 Subpart B:2018                                                           Radiated Emissions

         FCC Part 15 Subpart B:2018                                                           Conducted Emissions




The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not
referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not
constitute authorization for the use of any TÜV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or
endorsement


    Project #0000163636                                   Report # 31951956.001                                                    Page 23 of 26
        Report Date:4/22/19                                               Rev. 0

           4.7        EUT Clock/Oscillator Frequencies
                  Reference Designation                           Speed (MHz)                                Type
       Transceiver                                                   310 – 390                  ☐ Oscillator ☐ Microprocessor
                                                                                                   ☒ Intentional Radiator
       Transceiver                                                   902 – 928                  ☐ Oscillator ☐ Microprocessor
                                                                                                   ☒ Intentional Radiator
       Wi-Fi Transceiver                                           2412 – 2462                  ☐ Oscillator ☐ Microprocessor
                                                                                                   ☒ Intentional Radiator
       Bluetooth LE Transceiver                                    2402 – 2480                  ☐ Oscillator ☐ Microprocessor
                                                                                                   ☒ Intentional Radiator
       300 MHz/900 MHz Transceiver IC                                     30                    ☒ Oscillator ☐ Microprocessor
                                                                                                   ☐ Intentional Radiator
       300 MHz/900 MHz Transceiver IC                                   0.032                   ☒ Oscillator ☐ Microprocessor
                                                                                                   ☐ Intentional Radiator
       Wi-Fi Transceiver IC                                              38.4                   ☒ Oscillator ☐ Microprocessor
                                                                                                   ☐ Intentional Radiator



           4.7.1       Radiated Emissions, Upper Frequency

                 Max Oscillator Frequency                 Max Radiated Spurious Emissions Measurement Frequency

         ☐       Less than 108 MHz                        Scan to 1 GHz

         ☐       Less than 500 MHz                        Scan to 2 GHz

         ☐       Less than 1000 MHz                       Scan to 5 GHz

         ☒       Greater than 1000 MHz                    Scan to 5th Harmonic



           4.8        EUT Test Program
           None

           4.9        EUT Modes of Operation
           The EUT is set to idle mode with no transmission

           4.10       Monitoring of EUT during Testing
           The EUT will be monitored by visual observation using a spectrum analyzer.
           Prior to each tests the EUT is set to idle mode with no transmission.



The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not
referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not
constitute authorization for the use of any TÜV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or
endorsement


    Project #0000163636                                   Report # 31951956.001                                                    Page 24 of 26
        Report Date:4/22/19                                               Rev. 0

           4.11       EUT Configuration

           4.11.1 Description
                                   Configuration                                                    Description
                                     Tabletop                                     EUT is a standalone equipment placed on tabletop


               Notes




The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not
referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not
constitute authorization for the use of any TÜV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or
endorsement


    Project #0000163636                                   Report # 31951956.001                                                    Page 25 of 26
        Report Date:4/22/19                                               Rev. 0

           4.12       Emissions

           4.12.1 Radiated Emissions

           4.12.1.1        Preliminary Radiated Emissions Test Setup
             Standard                     FCC Part 15 Subpart B:2018                                        Procedure          QP090715
             Limit                        Class B                            Emissions Verification              Emissions Under Limit
             Frequency Range              30 MHz – 18 GHz
                                          Pre-scan                               Antenna
                    Scan #1               30 – 1000 MHz                                              3m        Detector                Max Peak
                                                                                 Distance
                                          Pre-scan                               Antenna
                    Scan #2               1 – 1 8GHz                                                 3m        Detector                Max Peak
                                                                                 Distance
             Notes                        None



           4.12.1.2        Final Radiated Emissions Test Setup
             Standard                     FCC Part 15 Subpart B:2018                                      Procedure               QP090715
             Limit                        Class B                            Emissions Verification              Emissions Under Limit
             Frequency Range              30 MHz – 18 GHz
                                          Final Scan                             Antenna
             Scan #1                      30 – 1000 MHz                                              3m        Detector               Quasi Peak
                                                                                 Distance
                                          Final Scan                             Antenna                                              Max Peak,
             Scan #2                                                                                 3m        Detector
                                          1 – 18 GHz                             Distance                                              Average
             Notes                        None




The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not
referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not
constitute authorization for the use of any TÜV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or
endorsement


    Project #0000163636                                   Report # 31951956.001                                                    Page 26 of 26
        Report Date:4/22/19                                               Rev. 0




                                                           END OF REPORT




The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not
referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not
constitute authorization for the use of any TÜV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or
endorsement