WIRING                                                                                                                                   WIRE THE OPERATOR TO THE CONTROL BOARD



WIRE THE OPERATOR ARM TO THE CONTROL BOARD
1   Insert the operator cable through the watertight connector mounted in the
    bottom of the control box.

2   Extend the operator cable and wires to the Gate 1 connector and connect
    as shown.


3   Tighten watertight connector nut.




                                                                                                                               S LAR /
                                                                                                                                HARGER
                                                                     BR GRN WHT YEL BLU RE            BR   RN WHT YEL BLU RE    +   -
                                                                                             GATE 2
                                                            GATE 1




                                                                                                                        !




If installing one operator, proceed to page 22. If installing two operators, continue to the next page.


                                                                                                                      19


WIRING                                                                                                                                                   DUAL GATES ONLY
                                                                 DUAL GATES ONLY

 INSTALL THE EXTENSION CABLE AND JUNCTION BOX

 Before digging, contact local underground utility locating companies. The
 following items are required to complete the junction box installation:
       • 4 x 4 Junction Box with 3/4" NPT threaded port holes
       • Screws
       • PVC Conduit                                                                                                                      Junction Box
       Trench across driveway to bury the extension cable. Use PVC conduit to
 1     prevent damage to cables.
                                                                                                   Extension Cable
                                                                                                                                                  Operator Cable



 2    Open the junction box by removing screws (4) and set aside.


 3    Mount the junction box within 3 feet (0.9 m) of second operator.


 4    Route operator cable and extension cable through watertight connector
      nut and watertight connector.                                                                   !                               !
                                                                                                                                                                   Within

 5    Insert cables and watertight connectors into the holes in the bottom of the
      junction box (not provided).
                                                                                                                                                                   3 feet




 6    Feed extension cable through PVC conduit and secure with nut.
                                                                                                     PVC Conduit




 WIRE THE EXTENSION CABLE TO THE SECONDARY OPERATOR

 1    Insert wires from extension cable and operator cable into the terminal
      block connector as shown (like-colored wires must face each other).

 2    Put wires inside of junction box.

 3    Secure operator and extension cables with watertight connector nut.

 4    Reinstall cover.
                                                                                                           Terminal Block Connector




                                                                                         Extension Cable                              Operator Cable




                                                                                    20


WIRING                                                                                                                                                                                                                                                                        DUAL GATES ONLY

                                                                   DUAL GATES ONLY

 WIRE THE EXTENSION CABLE TO THE CONTROL BOARD


 1     Choose a knockout in the bottom of the control box.


 2     Insert a watertight connector through the knockout and tighten with nut.                                                                                                                                                                         Extension Cable



 3     Insert the extension cable through watertight connector.                                                           BRO GRN         HT YEL BLU RED                               BRO GRN WHT YEL BLU RED
                                                                                                                                                                                                                                 SOLAR /
                                                                                                                                                                                                                                 CHARGER
                                                                                                                                                                                                                                     +




                                                                                                                                                                              GATE 2
                                                                                                                 GATE 1
  4    Extend the cable and wires to Gate 2 connector on the control board.
       Connect wires as shown.


 5     Tighten the watertight connector nut to secure extension cable to control
       box.
                                                                                                                                                                                                                                                    !                     !




 SET THE BIPART DELAY

 Occasionally in dual gate installations, one gate will need to open first and close
 second. This would happen if there was an ornamental overhang on one gate or                                                                                                                                 OUTSIDE PROPERTY
 if using a solenoid lock, for example. This gate is called the Primary gate and
 needs to be connected to Gate 1 connections on the control board. Thus, it is
 preferred that the control box be installed on the same side as this gate. If
 there is no appropriate location on that side for the control box, then mount the          Primary Gate
 control box on the opposite side, but connect the operator closest to the control
 box to the Gate 2 connector and the operator on the opposite side to the Gate 1
 connector.
                                                                                                Primary Gate - Connect to Gate 1 Connector on Control Board.
 NOTE: The gate with the longer travel span (opening) must be set as the
 primary gate (GATE 1).

 1    The BIPART DELAY switch on the control board needs to be set to the ON
      position.
                                                                                                                                                                                                                                                                    BIPART          L
                                                                                                                    SET OPEN SET C OSE

                                                                                                                                                                                                M T ER
                                                                                                                                                                                                                                                        LOSE
                                                                                                                                                                                                                    O




                                                                                                                                                           O F          ON

                                                                                                                                                R S&
                                                                                                                                                 L A E
                                                                                                                                               T B GN
                                                                                                                                                 MIT
                                                                                                                                                                  ( E ON S)
                                                                                                                                                                     10
                                                                                                                                                                                                                                                                    DELAY
 The following illustration shows a dual gate configuration with a decorative
                                                                                                                                                                                                                    SE




                                                                                                                  MO E
                                                                                                                  G TE
                                                                                                                                                   2
                                                                                                                                                           5                     0
                                                                                                                                                                                                                    STOP




                                                                                                                                                                                                                                   EX T
                                                                                                                                                            F                 80
                                                                                                                                      NP T POWER                  MER                  B TT L W           I GNOS I
                                                                                                                 STATUS




 overlapping piece on the outside of the gate.
                                                                                                                                      B TT C ARG NG               ATE M V NG           ACC WR     VL       CO ES                S AD W
                                                                                                                                                                                                                                 C OSE
                                                                                                                                                                                                                                  E

                                                                                                                                                                                                                              NTE RUP
                                                                                                                                                                                                                                          +




                                                                                                                                                                                                                                                                  OFF         ON
                                                                                                                                                                                                                                        +




 If a solenoid lock is being used on a gate, the gate with the lock attached to it                                                                                                                                                                                        TIMER
                                                                                                                                                                                                                                     J5




 is the primary gate.
                                                                                                                                                                                                                                           NC
                                                                                                                                                                                                                                           M




                                                                                                                                                   15                                                                             LOCK
                                                                                                                                                                                                                                           NO




                                                                                                                          +                +
                                                                                                                                                                                                                                  AC ESS RY
                                                                                                                                                                                                                                         SW




                                                                                                                              A T      DC
                                                                                                                                       POW R
                                                                                                                                                                                                                                     OWER
                                                                                                                                                                                                                                       +
                                                                                                                                                                                                                                      ON
                                                                                                                                                                                                                                          +
                                                                                                                                                                                                                                            B ARD
                                                                                                                                                                                                                                              XP




                                                                                                                                                                        OL R /
                                                                                                                                                                        HAR ER
                                                                                                     BR GRN WT E B U      ED        BR GRN WT     E      LU R D           +


                                                                                                                                                                                                         ID R SET     AL RM




                                                                                       21


WIRING                                                                                                                                                                    POWER WIRING

POWER WIRING                                                                                                        NUMBER OF CYCLES PER DAY
This operator can be wired for either 120 Vac or a solar panel (not                          Swing Gate Installation (6 ft. 1200 lb. gate/ 19 ft. 500 lb. gate)
provided). Follow the directions according to your application. For dual                              CONFIGURATION                               SINGLE GATE                  DUAL GATE
gate applications, power will have to be connected to each operator.                                                                             7AH    33AH Batteries       7AH    33AH Batteries




                                                                                                   Solenoid Lock
Main power supply and control wiring MUST be run in separate                                                                                  Batteries  (optional for    Batteries (optional for
conduits.




                                                                                                                           100 mA
                                                                                                                                    300 mA
                                                                                                                                             (standard) Large Metal      (standard) Large Metal




                                                                                                                   50 mA
                                                                                                                                                         Control Box)                Control Box)
                                                                                   TOROID                                                    Continuous Continuous       Continuous Continuous
  AMERICAN WIRE             MAXIMUM WIRE                    MAXIMUM WIRE
                                                                                   POWERED           ✔                                       Continuous Continuous          2059        2056
   GAUGE (AWG)             LENGTH (120 VAC)                LENGTH (240 VAC)                                         ✔                        Continuous Continuous       Continuous Continuous
          14                       130 feet                      260 feet                                                   ✔                Continuous Continuous       Continuous Continuous
                                                                                                                                      ✔      Continuous Continuous       Continuous Continuous
          12                       205 feet                      410 feet
                                                                                   BATTERY                                                       215        1202              98         612
          10                       325 feet                      650 feet          POWERED           ✔                                           122         763              71         443
                                                                                                                    ✔                            207        1292              96         600
           8                       520 feet                     1040 feet
                                                                                                                            ✔                    200        1249              94         590
           6                       825 feet                     1650 feet                                                             ✔          178        1111              88         554
                                                                                   TRANSFORMER                                                  1726        1720            1347        1340
           4                      1312 feet                     2624 feet
                                                                                   POWERED     ✔                                                1359        1352            1147        1140
NOTE: Use copper conductors ONLY.                                                                                   ✔                           1670        1663            1301        1293
                                                                                                                            ✔                   1615        1607            1257        1248
                                                                                                                                      ✔         1391        1380            1075        1064




 120 VAC                                                                                                                              STANDARD CONTROL BOX


1    Turn off the AC power from the main power source circuit breaker.


2    Run the AC power wires to the control box.


3    Remove the junction box cover.


4    Connect the green wire to the earth ground rod wire using a wire nut.


5    Connect the white wire to NEUTRAL using a wire nut.

6    Connect the black wire to HOT using a wire nut.
                                                                                                                                    Junction
                                                                                                                                    Box Cover

7    Replace the junction box cover. Ensure the wires are not pinched.
                                                                                                                                      LARGE METAL CONTROL BOX (XLM)




                                                                                                               Junction
                                                                              22                               Box Cover


WIRING                                                                                                                                                                          POWER WIRING + CONNECT BATTERIES

POWER WIRING CONTINUED...                                                                                                                                       NUMBER OF CYCLES PER DAY (SOLAR)
                                                                                                                                                              Swing Gate Installation (6 ft. 1200 lb. gate/19 ft. 500 lb.)
 SOLAR PANEL(S)                                                                                                                                                                          Single Gate

NOT PROVIDED. SEE ACCESSORIES.                                                                                                                                                  CONFIGURATION                                                       ZONE 1                                                 ZONE 2                                            ZONE 3
                                                                                                                                                                                                                                                  (6 Hrs                                               (4 Hrs                                                    (2 Hrs
The solar panel(s) must be located in an open area clear of obstructions and shading                                                                                                                                                          sunlight/day)                                         Sunlight/day)                                               Sunlight/
for the entire day. The gate operator is not supported in northern climates where                                                                                                                                                                                                                                                                                 day)
temperatures reach below -4˚F. This is due to cold weather and a reduced number of




                                                                                                                                                                                                                                                                    33AH Batteries (optional)




                                                                                                                                                                                                                                                                                                                            33AH Batteries (optional)



                                                                                                                                                                                                                                                                                                                                                                                   33AH Batteries (optional)
                                                                                                                                                                                                                                        7AH Batteries (standard)




                                                                                                                                                                                                                                                                                                7AH Batteries (standard)



                                                                                                                                                                                                                                                                                                                                                        7AH Batteries (standard)
hours of sunlight during the winter months. Cycle rate may vary from solar chart for
areas that reach below 32˚F. Solar panels should be cleaned on a regular basis for




                                                                                                                                                                                                     Expansion Board
                                                                                                                                                                                                                       1 Loop (LD7LP)
best performance to ensure proper operation. For solar applications, a minimum of




                                                                                                                                                                                         High Band
                                                                                                                                                                              Low Band
two 10W solar panels in series and two 7AH batteries are recommended. For Zone 3
cold weather sites, two 33AH batteries are recommended (for Large Metal Control
Box (XLM) ONLY). We recommend LiftMaster low power draw accessories to minimize                                                                                                                                                            120                            154                        76                        96                            33                       38
                                                                                                                                                 20W SOLAR PANEL
power draw, refer to accessory page.                                                                                                                                           ✔                                                           117                            151                        74                        93                            30                       35
                                                                                                                                                 NOTE: 20W would be two 10W
                                                                                                                                                                               ✔         ✔                                                 111                            144                        68                        87                            25                       29
1    Locate the solar/charge plug on the control board and remove the transformer                                                                (12V) panels in series.
                                                                                                                                                                               ✔                         ✔                                 109                            142                        66                        84                            23                       27
     wires from the plug.                                                                                                                                                      ✔         ✔               ✔              ✔                   99                            131                        56                        74                            13                       17
                                                                                                                                                 40W SOLAR PANEL                                                                           156                            202                       101                       128                            45                       54

2    Connect the red (+) wire from the solar panel to the solar/charge plug (+).                                                                 NOTE: 40W would be two 20W
                                                                                                                                                 panels in series.
                                                                                                                                                                               ✔
                                                                                                                                                                               ✔         ✔
                                                                                                                                                                                                                                           154
                                                                                                                                                                                                                                           148
                                                                                                                                                                                                                                                                          199
                                                                                                                                                                                                                                                                          193
                                                                                                                                                                                                                                                                                                     98
                                                                                                                                                                                                                                                                                                     92
                                                                                                                                                                                                                                                                                                                              125
                                                                                                                                                                                                                                                                                                                              119
                                                                                                                                                                                                                                                                                                                                                             42
                                                                                                                                                                                                                                                                                                                                                             37
                                                                                                                                                                                                                                                                                                                                                                                      51
                                                                                                                                                                                                                                                                                                                                                                                      45
                                                                                                                                                                               ✔                         ✔                                 145                            190                        90                       117                            35                       43

3    Connect the black (-) wire from the solar panel to the solar/charge plug (-).                                                                                             ✔         ✔               ✔              ✔                  135                            179                        80                       106                            25                       33
                                                                                                                                                                                          Dual Gates

4    Plug in the solar/charge plug.                                                                                                              20W SOLAR PANEL
                                                                                                                                                 NOTE: 20W would be two 10W
                                                                                                                                                                               ✔
                                                                                                                                                                                                                                               54
                                                                                                                                                                                                                                               53
                                                                                                                                                                                                                                                                              69
                                                                                                                                                                                                                                                                              68
                                                                                                                                                                                                                                                                                                        34
                                                                                                                                                                                                                                                                                                        33
                                                                                                                                                                                                                                                                                                                                   43
                                                                                                                                                                                                                                                                                                                                   42
                                                                                                                                                                                                                                                                                                                                                              15
                                                                                                                                                                                                                                                                                                                                                              13
                                                                                                                                                                                                                                                                                                                                                                                       17
                                                                                                                                                                                                                                                                                                                                                                                       16
                                                                                                                                                 (12V) panels in series.       ✔          ✔                                                    50                             65                        31                         39                         11                       13
                                                                                                                                                                               ✔                         ✔                                     49                             64                        30                         38                         10                       12
                                                                                                                          +




                                                                                                                                                                               ✔          ✔              ✔               ✔                     45                             60                        25                         33                          6                        7
                                                                                                                          -




                                                                                                                                                 40W SOLAR PANEL                                                                               71                             92                        46                         58                         20                       24
                                                                                                                       J5




                                                                                                                                                                               ✔                                                               70                             90                        44                         57                         19                       23
                                                                                                                                                 NOTE: 40W would be two 20W
                                                                                                                                                                                                                                               67                             87                        42                         54                         16                       20
                                                                      J15                                           LOCK


                                            +          -      -   +
                                                                                                                                                 panels in series.             ✔          ✔
                                                                                                                           SW.
                                                                                                                             -
                                                                                                                    ACCESSORY




                                                BATT          DC



                                                                                                                                                                                                                                               66                             86                        41                         53                         16                       19
                                                              POWER
                                                                                                                      POWER




                                                                                                                                                                               ✔                         ✔
                                                                                                                         +
                                                                                                                    ON




                                                                                                                                                                               ✔          ✔              ✔               ✔                     62                             81                        36                         48                         11                       15
                                                                                                                            CL S 2 S PP Y
                                                                                                                            24 O TS
                                                                                                                               EXP.
                                                                                                                              BOAR




                                                                                  SOLAR /
                                                                                  CHARGER                          GROUND
                           BR GRN WT YE BLU RED            BR GRN WT YE BLU RED    +


                                                                                                ID RESET   ALARM




                                                                                                                                                      3                                                                                                                                                                    NOT AVAILABLE
                                                                                        Black
                                                                            Red




                                                                                                                                                                     NOT AVAILABLE
                                                                            (to solar panel)
                                                                                                                                                  2                                                                           3


                                                                                                                                                                 1                                   2
                                                                                                                                                                                                                                                                                                                                                        1


                                                                                                                                                                                                                                                              1



CONNECT BATTERIES
The batteries are charged in the circuit by the transformer or solar panel.

 STANDARD CONTROL BOX
                                                                                                                                                                                                                                                                   Battery

1    Turn OFF AC power to the operator at the circuit breaker.                                                                                                                                                                                                     Connector



2
                                                                                                                                                                                                                                                                                                                           J15 Plug
     Plug the battery connector to the J15 plug labeled BATT(-)(+) DC(-)(+) on the
     control board. The control board will power up.

3    Turn ON AC power to the operator.
                                                                                                                                            23


WIRING                                                                                     CONNECT BATTERIES + ENGAGE THE OPERATOR

CONNECT BATTERIES
The batteries are charged in the circuit by the transformer or solar panel.

 LARGE METAL CONTROL BOX (XLM)

7AH BATTERIES

1    Turn OFF AC power to the operator at the circuit breaker and unplug the
     transformer.


2
                                                                                                            Battery
     Unplug the battery connector to the J15 plug labeled BATT(-)(+) DC(-)(+) on                            Connector
     the control board by squeezing the plug and pulling it from the control board.
                                                                                                                         J15 Plug
     Connect a jumper between the positive (+) terminal of one battery to the
3    negative (-) terminal of the other battery.                                                                             Jumper
                                                                                                                                      Black Wire
                                                                                                              Red Wire
     Connect the red wire from the J15 plug labeled BATT (+) to the positive (+)
4    terminal of the battery.

     Connect the black wire from the J15 plug labeled BATT (-) to the negative (-)
5    terminal of the battery.

6    Plug the J15 plug into the control board. The control board will power up.


7    Plug the transformer in.


8    Turn ON AC power.




33AH BATTERIES
33AH batteries can be used in place of the 7AH batteries for a Large Metal Control
Box (XLM) solar application ONLY. A wall or column mount installation is
recommended when using the 33AH batteries.




ENGAGE THE OPERATOR
1     Turn the release lever clockwise 180°. This engages the motor.


2     Turn the key clockwise 180°. This locks the release lever.

The operator is now engaged.




                                                                                      24


ADJUSTMENT                                                                                                                                                                                                                 LIMIT AND FORCE ADJUSTMENT


LIMIT AND FORCE ADJUSTMENT



  To reduce the risk of SEVERE INJURY or DEATH:
  • Without a properly installed safety reversal system, persons (particularly small         • NEVER use force adjustments to compensate for a binding or sticking gate.
     children) could be SERIOUSLY INJURED or KILLED by a moving gate.                        • If one control (force or travel limits) is adjusted, the other control may also
  • Too much force on gate will interfere with proper operation of safety reversal             need adjustment.
     system.                                                                                 • After ANY adjustments are made, the safety reversal system MUST be tested.
  • NEVER increase force beyond minimum amount required to move gate.                          Gate MUST reverse on contact with a rigid object.


INTRODUCTION
Your operator is designed with electronic controls to make travel limit and force                                                                 LIMIT SETUP LEDS
adjustments easy. The adjustments allow you to program where the gate will stop in            SET OPEN                         SET CLOSE                                                              OPERATOR MODE                                                              EXPLANATION
the open and close position. The electronic controls sense the amount of force                LED                              LED
required to open and close the gate. The force is adjusted automatically when you
                                                                                              BLINKING                         BLINKING                                                               NORMAL MODE                                                                Limits are not set.
program the limits but should be fine tuned using the REVERSAL FORCE dial on the
control board (refer to Fine Tune the Force section) to compensate for environmental          OFF                              OFF                                                                    NORMAL MODE                                                                Limits are set.
changes.                                                                                      BLINKING                         BLINKING                                                               LIMIT SETTING MODE                                                         Limits are not set.
The limits can be set using the control board (below) or a remote control (refer to
                                                                                              BLINKING                         ON                                                                     LIMIT SETTING MODE                                                         Open limit is not set.
Limit Setup with a Remote Control in the Additional Features section). Setting the
limits with a remote control requires a 3-button remote control programmed to                 ON                               BLINKING                                                               LIMIT SETTING MODE                                                         Close limit is not set.
OPEN, CLOSE, and STOP.                                                                        ON                               ON                                                                     LIMIT SETTING MODE                                                         Limits are set.




INITIAL LIMITS AND FORCE ADJUSTMENT
For dual gate applications the limits will have to be set for each
operator. The gate MUST be attached to the operator before setting the
limits and force.
                                                                                              1                                                                2
                                                                                                                                                                                                                                                                       3
                                                                                                                               O
                                                                                                                                    TI

1    Set the GATE switch to the 1 position.
                                                                                                                     PRESS &
                                                                                                                     RELEASE       TO CL
                                                                                                                    TO BEG N          (SECOND                      SET OPEN                                     SET CLOSE
                                                                                                                    LIMIT                     10
                                                                                                                    SETUP
                                                                                                                         1                                                                                                                                                                 PR




2
                                                                                                                                                                                                                                                                                           REL

     Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter                                   GATE
                                                                                                                         2
                                                                                                                               5                                                                                                                             O
                                                                                                                                                                                                                                                                                          TO BEG
                                                                                                                                                                                                                                                                                             LIMI
                                                                                                                                                                                                                                                                                             SETUP
     limit setting mode.                                                                                                       OFF
                                                                                                                                                                                                                                                                   MOVE
                                                                                                                                                                                                                                                                   GATE
                                                                                                                                                                                                                                                                                                  1

                                                                                                     INPUT POWER                   TIM                                                                                                                                                            2
                                                                                                                    ARGIN                                                                                                                                                                    GAT


3    Press and hold the MOVE GATE buttons to move the gate to the open or close
                                                                                                                                                                                                                                                                                                              4
                                                                                                                                                  SET OPEN       SET CLOSE

                                                                                                                                                                                                                     T R
                                                                                                                                                                                                                                  OPEN




                                                                                                                                                                                                                     ORK
                                                                                                                                                                                   OFF        ON




     limit.
                                                                                                                                                                                                                                                                                   INPU
                                                                                                                                                                         R L A E

                                                                                                                                                                                                                                                                           US:
                                                                                                                                                                                                                                  C OSE




                                                                                                                                                                         OB GN           S
                                                                                                                                                                         L MIT               10                                                IRE
                                                                                                                                                                         S TUP                                                                DEPT
                                                                                                                                                 MOVE                        1
                                                                                                                                                 GATE
                                                                                                                                                                             2
                                                                                                                                                                                   5                  60
                                                                                                                                                                                                                                  STOP




                                                                                                                                                                                   OF                 80

                                                                                                                                                STATUS
                                                                                                                                                                NPUT POWER                                 ATT LOW         D AGNOST
                                                                                                                                                                                                                             CODES
                                                                                                                                                                                                                                                                           SET OPEN   SET CLOSE             BIP


4
                                                                                                                                                                 ATT CHARG NG           G TE MOV NG        CC PWR OVL                       SH DOW
                                                                                                                                                                                                                                             CLO E

                                                                                                                                                                                                                                                                                                            DEL
     Press and release the SET CLOSE or SET OPEN button depending on which limit
                                                                                                                                                                                                                                          INT RR




     is being set.
                                                                                                                                                                                                                                                    +




                                                                                                                                                                                                                                                                                                            OFF
                                                                                                                                                                                                                                                   J5




                                                                                                                                                                                                                                                                                              PRESS &
                                                                                                                                                                                                                                                                                              RELEASE
                                                                                                                                                                                                                                                        NC




5
                                                                                                                                                                             15                                                                OCK                                           TO BEG
                                                                                                                                                                                                                                                        NO




     Press and hold the MOVE GATE button to move the gate to the other limit.
                                                                                                                                                    +                +
                                                                                                                                                                                                                                               CCESSORY
                                                                                                                                                                                                                                                     SW




                                                                                                                                                        B TT     DC
                                                                                                                                                                 POWER
                                                                                                                                                                                                                                                POWER




                                                                                                                                                                                                                                                                                                             5
                                                                                                                                                                                                                                                   +




                                                                                                                                                                                                                                                                                                 P
                                                                                                                                                                                                                                               N




                                                                                                                                                                                                                                                                                                 REL
                                                                                                                                                                                                                                                        +




                                                                                                                                                                                                                                                                                                TO BE
                                                                                                                                                                                                                                                                                                 LIMI
                                                                                                                                                                                                                                                         OARD
                                                                                                                                                                                                                                                         EXP




                                                                                                                                                                                                                                                                                                 SETUP



6
                                                                                                                                                                                             SOLAR /
                                                                                                                                                                                                                                                                       MOVE
     Press and release the SET CLOSE or SET OPEN button depending on which limit
                                                                                                                                                                                             CHARGER                                         G OUND
                                                                                                                                   R GRN WT   E BLU R D        R GRN WT YE BLU ED                 +
                                                                                                                                                                                                                                                                                                        1
                                                                                                                                                                                                                                                                       GATE
                                                                                                                                                                                                                                                                                                        2

     is being set.                                                                                                                                                                                                                                                                              GAT

                                                                                                                                                                                          SET OPEN                         SET CLOSE                             BI
                                                                                                                                                                                                                                                                 DEL                  INPU



7
                                                                                                                                                                                                                                                                            TUS:
     Cycle the gate open and close. This automatically sets the force.
                                                                                                                                                                                                                                                                       6
                                                                                                                !
                                                                                                                                                                                                                                                                 OFF
                                                                                                                    it                        OP
                                                                                                            lim                                                                                                                            PRESS &
                                                                                                      O  SE                                         EN                                                                                     RELEASE

When limits are set properly the operator will automatically exit limit setting mode.               CL                                                          lim
                                                                                                                                                                           it
                                                                                                                                                                                                                                          TO BEG




DUAL GATES: Set the GATE switch to the 2 position and repeat steps 2-7 for the
secondary gate.                                                                                                                                                                                       7
                                                                                        25


ADJUSTMENT                                                                                                                         LIMIT AND FORCE ADJUSTMENT + OBSTRUCTION TEST

FINE TUNE THE FORCE
The FORCE DIAL on the control board is used for fine tuning the force in cases where
wind or environmental changes may affect the gate travel.                                                                                                                                                                                                                                                                          TEST


                                                                                                                                                                                                                                                                                      1
                                                                                                                                                                                                                                                                                                                                 BUTTONS

Based on the length and weight of the gate it may be necessary to make additional
                                                                                                                                                                                                                                                                                                                 TTER




                                                                                                                                                                                                                                                                                                                                        OPEN
                                                                                                                                                                                                                                                                                                               TWORK


force adjustments. The force setting should be high enough that the gate will not                                                                                                                                                                                                                             RSAL
                                                                                                                                                                                                                                                                                                               CE
reverse by itself nor cause nuisance interruptions, but low enough to prevent serious




                                                                                                                                                                                                                                                                                                                                        CLOSE
injury to a person. The force setting is the same for both the open and close gate
                                                                                                                                                                          S T O EN        S T           LOSE

                                                                                                                                                                                                                                                      X I   ER

                                                                                                                                                                                                                                                      N T O K
                                                                                                                                                                                                                    O F              ON




directions.
                                                                                                                                                                                                                                                                                                                                                                                       2
                                                                                                                                                                                                             S
                                                                                                                                                                                                        O                       S C N S)
                                                                                                                                                                                                            MT                    10
                                                                                                                                                                                                        S




                                                                                                                                                                                                                                                                                                                                        STOP
                                                                                                                                                                         MOVE                                1
                                                                                                                                                                         GATE
                                                                                                                                                                                                             2
                                                                                                                                                                                                                        5                   6




1
                                                                                                                                                                                                                        FF                 18   MN          M
                                                                                                                                                                                                                                                                           T
                                                                                                                                                                        S ATUS
                                                                                                                                                                                           A T C AR I G                         A E M V NG      A C PWR O L                           H




       Open and close the gate with the TEST BUTTONS.
                                                                                                                                                                                                                                                                                      C OS
                                                                                                                                                                                                                                                                                        Y S




                                                                                                                                                                                                                                                                                                                                                  NETWORK

                                                                                                                                                                                                                                                                                                                                     REVERSAL




                                                                                                                                                                                                                                                                                          5
                                                                                                                                                                                                                                                                                                                                      FORCE


2
                                                                                                                                                                                                             15




      If the gate stops or reverses before reaching the fully open or closed position,




                                                                                                                                                                                                                                                                                              Y
                                                                                                                                                                                                                                                                                              W
                                                                                                                                                                                 B TT     DC
                                                                                                                                                                                           OW R




                                                                                                                                                                                                                                                                                        P WER
                                                                                                                                                                                                                                                                                       N
                                                                                                                                                                                                                                                                                       C
      increase the force by turning the force control slightly clockwise.




                                                                                                                                                                                                                                                                                                  OA D
                                                                                                                                                                                                                                                                                                  EXP
                                                                                                                                                                                                                                      OL R /
                                                                                                                                                                                                                                     C A GER
                                                                                                                                                        BR G N WT E      LU R D         BR G N WT YE B U ED


                                                                                                                                                                                                                                                                 D R S T       L RM
                                                                                                                                                                                                                                                                                                                             60




3
                                                                                                                                                                                                                                                                                                                                  MIN                     MAX
      Perform the “Obstruction Test” after every force setting adjustment (see                                                                                                                                                                                                                                                      BATT LOW


      below).
                                                                                                                                                                                                                                                                                                                                           WR




ADJUST THE LIMITS

If the limits have already been set the operator will exit the limit setting mode after
resetting each limit. Each limit is set separately by following steps 1-3 of the Initial
Limit and Force Adjustment section.



ERASE LIMITS

1     To erase the limits, press and hold the SET OPEN and SET CLOSE buttons
      simultaneously (5 seconds) until both the SET OPEN and SET CLOSE LEDs blink
                                                                                                                                                                                                                                                                                                                                                                                                      ER




                                                                                                                                                                                                                                                                                                                                                                                                                          OPEN
                                                                                                                                                                                                                                                                                                                                                                                                           K
                                                                                                                                                                                                                                                                                                                                                                       FF          N
                                                                                                                                                                                                                                                                                                                                                                                                                                                  S C




                                                                                                                                                                                                                                                                                                                                                                                                                          CLO E
                                                                                                                                                                                                                                                                                                                                                                 LMT           0                                                               F RE

                                                                                                                                                                                                                                                                                                                                                MOVE




      rapidly and the operator beeps.                                                                                                                                                                                                                                                                                   B
                                                                                                                                                                                                                                                                                                                                                GATE


                                                                                                                                                                                         SET OPEN SET CLOSE
                                                                                                                                                                                                                                                                                                                                                                   2




                                                                                                                                                                                                                                                                                                                                                                                                                          STOP
                                                                                                                                                                                                                                                                                                                                                                                         I



                                                                                                                                                                                                                                                                                                                        D
                                                                                                                                                                                                                                                                                                                                                          P T PO ER                          A T OW             I GN S I
                                                                                                                                                                                                                                                                                                                                                S ATUS                                                           C DES
                                                                                                                                                                                                                                                                                                                                                          TT HA G N         AT MO I G        CC WR O L                                     S
                                                                                                                                                                                                                                                                                                                                                                                                                                               L SE
                                                                                                                                                                                                                                                                                                                                                                                                                                               E E /

                                                                                                                                                                                                                                                                                                                                                                                                                                         I T RR




2
                                                                                                                                                                                                                                                                                                                        F
      Release the buttons and the SET OPEN and SET CLOSE LEDs will blink slowly




                                                                                                                                                                                                                                                                                                                                                                                                                                                  5
                                                                                                                                                                                                                                                                                                                                                                   5




                                                                                                                                                                                                                                                                                                                                                                                                                                                           O
      indicating the limits will need to be set.




                                                                                                                                                                                                                                                                                                                                                                                                                                               A CE S RY
                                                                                                                                                                                                                                                                                                                                                                                                                                                     SW
                                                                                                                                                                                                                                                                                                                                                   B TT   C
                                                                                                                                                                                                                                                                                                                                                          OW R




                                                                                                                                                                                                                                                                                                                                                                                                                                                 P WER
                                                                                                                                                                                                                                                                                                                                                                                                                                               ON
                                                                                                                                                                                                                                                                                                                                                                                                                                                           XP
                                                                                                                                                                                                                                                                                                                                                                               SO AR /
                                                                                                                                                                                                                                                                                                                                                                               CH R ER                                                         R UND



                                                                                                                                                                                                                                                                                                                                                                                                                D R S T           L RM




OBSTRUCTION TEST
The operator is equipped with an automatic obstruction sensing feature. If the gate
                                                                                                1                                                                                                                                                                   TTER
                                                                                                                                                                                                                                                                                             TEST
                                                                                                                                                                                                                                                                                           BUTTONS
                                                                                                                                                                                                                                                                                                                OPEN




                                                                                                                                                                                                                                                                 ETWORK
                                                                                                                S T O EN            ET      L SE




encounters an obstruction during motion, the operator will automatically reverse
                                                                                                                                                       FF      O
                                                                                                                                                                                                P N




                                                                                                                                                                                                                                                                RSAL
                                                                                                                                                                                                C O E




                                                                                                                                                              0                                                         I E

                                                                                                                OVE
                                                                                                                A E
                                                                                                                                                   5

                                                                                                                                                                                                                                                                 CE
direction of the gate for a short time and then stop the gate. After any adjustments
                                                                                                                                                                                                T P




                                                                                                                                                                                                                                                                                                                CLOSE




                                                                                                                                   N UT O ER            I ER            A T OW           A N S I
                                                                                                              S AT S                                                                      O ES
                                                                                                                                   B T C A GN               A EM V G    CC WR    V                                  H
                                                                                                                                                                                                                        O E


                                                                                                                                                                                                                  T R




are made, test the operator:
                                                                                                                                                                                                                                                                                                               STOP




1      Open and close the gate with the TEST BUTTONS, ensuring that the gate is
                                                                                                                                             J 5
                                                                                                                                                                                                                            W




                                                                                                                         TT
                                                                                                                                     WER
                                                                                                                                                                                                                        O
                                                                                                                                                                                                                            W
                                                                                                                                                                                                                            O




       stopping at the proper open and close limit positions.
                                                                                                                                                                                                                                 O




                                                                                                                                                               O AR /
                                                                                                                                                               H RG R
                                                                                                BR   R   WT E B U   ED        BR     N WT    E B U ED




                                                                                                                                                                                                                  2
2     Place a solid object between the open gate and a rigid structure. Ensure that
      the gate, the solid object, and the rigid structure can withstand the forces                                                                                                                                                                                                                                      !
      generated during this obstruction test.                                                                                                                                                                                                                                                                           im
                                                                                                                                                                                                                                                                                                                            it                             OP
                                                                                                                                                                                                                                                                                                               El                                                      EN
                                                                                                                                                                                                                                                                                                           OS
                                                                                                                                                                                                                                                                                                         CL                                                                              lim
                                                                                                                                                                                                                                                                                                                                                                                                               it

3     Run the gate in the close direction. The gate should stop and reverse upon
      contact with the solid object. If the gate does not reverse off the solid object,
      reduce the force setting by turning the force control slightly counter-clockwise.
      The gate should have enough force to reach both the open and close limits, but
      MUST reverse after contact with a solid object.
                                                                                                                                                                                                                                                                                      3                                                                                                  !




4     Repeat the test for the open direction.


                                                                                           26


PROGRAMMING                                                                                                                                                                                                                                                                                                                                                                  REMOTE CONTROLS + ERASE ALL CODES

REMOTE CONTROLS
A total of 50 Security✚ 2.0™ remote controls and 2 keyless entries (1 PIN for each keyless entry) can be programmed to the operator. NOTE: When the memory is full the
operator will exit programming mode and the remote control/keyless entry will not be programmed. The memory will need to be erased before programming any additional
remote controls/keyless entries. If installing an 86LM to extend the range of the remote controls DO NOT bend the antenna.

TO ADD OR REPROGRAM A REMOTE CONTROL
(NOT PROVIDED)

1                                                                                                                                                       1
                                                                                                                                                                                                                                                                                                                                       LEARN
      Press and release the LEARN button (operator will beep and green XMITTER LED                                                                                                                                                                                                                                                                                                                                                       BU
      will light).
                                                                                                                                                                                                                                                                                                                                                                                 XMITTER




2     Press the remote control button for the desired function. The operator will
                                                                                                                                                                                                                                                                                                                                                                                 NETWORK

                                                                                                                                                                                                                                                                                                                                                                                        SAL
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            2
      automatically exit learn mode (operator will beep and green XMITTER LED will                                                                                                            S T OP N                ET     LO E




                                                                                                                                                                                                                                           O F           ON




      go out) if programming is successful.
                                                                                                                                                                                                                                                        0                                                                  FR
                                                                                                                                                                                                                                                                                                                           D
                                                                                                                                                                                              OVE
                                                                                                                                                                                              A E
                                                                                                                                                                                                                                 2
                                                                                                                                                                                                                                            5                       0



                                                                                                                                                                                                                     P T O ER                   T   ER                      T L W               D G O T
                                                                                                                                                                                              T T S                                                                                               C D S
                                                                                                                                                                                                                     T C A GN                   G T M VN                    C WR O     D                                  S A
                                                                                                                                                                                                                                                                                                                           C S
                                                                                                                                                                                                                                                                                                                            E

                                                                                                                                                                                                                                                                                                                     N E R




This programming step will program a single button as an open, close, and stop. To
program additional Security✚ 2.0™ remote controls, repeat the steps until all the                                                                                                                                                  5                                                                                       L




                                                                                                                                                                                                                                                                                                                                   W
                                                                                                                                                                                                  A T                C
                                                                                                                                                                                                                     O ER




                                                                                                                                                                                                                                                                                                                           O
remote controls are programmed.




                                                                                                                                                                                                                                                                                                                               W
                                                                                                                                                                                                                                                                                                                                   O

                                                                                                                                                                                                                                                                                                                                           O
                                                                                                                                                                                                                                                        S L R/
                                                                                                                                                                                                                                                        C A G R                                                            R U D
                                                                                                                                                                     BR       R    WT E B U R D             BR       R     WT YE           UR D


                                                                                                                                                                                                                                                                                                D   E ET      L RM




PROGRAM OPEN ONLY ON A 1-BUTTON REMOTE
CONTROL
                                                                                                                                                    1                                                                                       LEARN


1       Press and release the LEARN button (operator will beep and green XMITTER LED                                                                                                                                                                                                                                                                          BU


                                                                                                                                                                                                                                                                                                                                                                                                                                   2                                                                   3
                                                                                                                                                                                                                                                                                                      XMITTER

        will light).                                                                                                                                                 N
                                                                                                                                                                                                                                                                                                     NETWORK




2       Press the OPEN button.
                                                                                                                                                                              ET OP N           S T CLO E

                                                                                                                                                                                                                                                                             M T R
                                                                                                                                                                                                                                                                                                                 SAL
                                                                                                                                                                                                                                                                                                                                                                        TTER
                                                                                                                                                                                                                                                                                                                                                                                                          TEST
                                                                                                                                                                                                                                                                                                                                                                                                        BUTTONS




3
                                                                                                                                                                                                                                                                              TW R




                                                                                                                                                                                                                                                                                                                                                                                                                                             OPEN
                                                                                                                                                                                                                                                                                                                                                                     TWORK
                                                                                                                                                                                                                            OFF             ON




                                                                                                                                                                                                                                                                                                       N
      Press the remote control button. The operator will automatically exit learn
                                                                                                                                                                                                            LMT




                                                                                                                                                                                                                                                                                                       LO E
                                                                                                                                                                                                                                            0                                                                                  I E
                                                                                                                                                                                                            S UP                                                                                                               E T
                                                                                                                                                                      MO E

                                                                                                                                                                                                                                                                                                                                                          RSAL
                                                                                                                                                                                                                                                                                                                               OP
                                                                                                                                                                      G TE
                                                                                                                                                                                                                  2
                                                                                                                                                                                                                            5                           6




                                                                                                                                                                                                                                                                                                       ST P
                                                                                                                                                                          TA US
                                                                                                                                                                                                                            O F                     1 0 MN                       M X

                                                                                                                                                                                                                                                                                                C DES
                                                                                                                                                                                                                                                                                                                                                          RCE

      mode (operator will beep and green XMITTER LED will go out) if programming
                                                                                                                                                                                                A T HA G NG                                                                                                                H D W




                                                                                                                                                                                                                                                                                                                                                                                                                                             CLOSE
                                                                                                                                                                                                                                     A E MO NG                      CC P R O L
                                                                                                                                                                                                                                                                                                                           C OS


                                                                                                                                                                                                                                                                                                                     NT R




      is successful.                                                                                                                                                                                                                                                                                                               5




                                                                                                                                                                                                                                                                                                                                                                                                                                             STOP
                                                                                                                                                                                                                 J 5                                                                                                           OC




To program additional Security✚ 2.0™ remote controls, repeat the steps until all the
                                                                                                                                                                                                                                                                                                                               Y
                                                                                                                                                                                                                                                                                                                                       W




                                                                                                                                                                                   B TT         DC
                                                                                                                                                                                                 OW R
                                                                                                                                                                                                                                                                                                                                OW R
                                                                                                                                                                                                                                                                                                                                       N
                                                                                                                                                                                                                                                                                                                               C




remote controls are programmed.
                                                                                                                                                                                                                                                                                                                                           B A D
                                                                                                                                                                                                                                                                                                                                             XP




                                                                                                                                                                                                                                            S L R/
                                                                                                                                                                                                                                            C A GER                                                                        G OU D
                                                                                                                                                        R G N WT E        U       ED         BR G N WT           E       L R D


                                                                                                                                                                                                                                                                                            D R S T           L RM




PROGRAM OPEN, STOP, AND CLOSE ON A 3-BUTTON
REMOTE CONTROL

1       Press and release the LEARN button (operator will beep and green XMITTER LED
        will light).
                                                                                                                                                    1
                                                                                                                                                                                                                                                         LEARN

                                                                                                                                                                                                                                                                                                                                                                                                                2
                                                                                                                                                                                                                                                                                                                                                                     BU


2
                                                                                                                                                                                                                                                                                                                 XMITTER

        Press the OPEN, CLOSE, or STOP button for the desired function.                                                                                                            N
                                                                                                                                                                                                                                                                                                                 NETWORK

                                                                                                                                                                                                                                                                                                                            SAL
                                                                                                                                                                                                                                                                                                                                                                                                                 TEST
                                                                                                                                                                                                                                                                                                                                                                                                               BUTTONS
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                       3
3
                                                                                                                                                                                                                                                                                                                                                                                 TTER


       Press the remote control button for the desired function. The operator will
                                                                                                                                                                                                                                                                                                                                                                                                                                                    OPEN




                                                                                                                                                                                               SET      PEN SET                 L SE
                                                                                                                                                                                                                                                                                                                                                                        ETWORK
                                                                                                                                                                                                                                                                                       MT   R




       automatically exit learn mode (operator will beep and green XMITTER LED will
                                                                                                                                                                                                                                                                                            R



                                                                                                                                                                                                                                                                                                                                                                  RSAL
                                                                                                                                                                                                                                                O F             N
                                                                                                                                                                                                                                                                                                                                           S C




                                                                                                                                                                                                                                                                                                                                                                  RCE
                                                                                                                                                                                                                                L IT                        0
                                                                                                                                                                                                                                S UP
                                                                                                                                                                                              M VE                                     1                                                                                               O E
                                                                                                                                                                                              G TE
                                                                                                                                                                                                                                       2
                                                                                                                                                                                                                                                5                       6
                                                                                                                                                                                                                                                                                                                                                                                                                                                    CLOSE




       go out) if programming is successful.
                                                                                                                                                                                                                     N U PO ER                      T    ER                  A T OW                  I G O T
                                                                                                                                                                                              T TU :                                                                                                   OD S
                                                                                                                                                                                                                      A TC A GN                     G T MO NG                C   PW    OV                                          H
                                                                                                                                                                                                                                                                                                                                   C O E
                                                                                                                                                                                                                                                                                                                                     Y S

                                                                                                                                                                                                                                                                                                                           N ER




To program additional buttons or Security✚ 2.0™ remote controls, repeat the steps
                                                                                                                                                                                                                                                                                                                                                                                                                                                    STOP




until all the buttons or remote controls are programmed.
                                                                                                                                                                                                                                   J 5                                                                                                  O K
                                                                                                                                                                                                                                                                                                                                              W




                                                                                                                                                                                                  B     T             DC
                                                                                                                                                                                                                                                                                                                                             R




                                                                                                                                                                                                                      P W R
                                                                                                                                                                                                                                                                                                                                         OW R
                                                                                                                                                                                                                                                                                                                                       CC
                                                                                                                                                                                                                                                                                                                                               O

                                                                                                                                                                                                                                                                                                                                                   O R




                                                                                                                                                                                                                                                            S L R/




ERASE ALL CODES
                                                                                                                                                                                                                                                            C A GER                                                                G O ND
                                                                                                                                                                     BR       RN       T E    U R D              R G N WT            E      U ED


                                                                                                                                                                                                                                                                                                                      M




1       Press and release the LEARN button (operator will beep and green XMITTER LED
        will light).
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                LEARN


2
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  BU
        Press and hold the LEARN button again until the green XMITTER LED goes out                                                                                                                                                                                                                                                                                                                                                                                                      XMITTER

        (approximately 6 seconds). All remote control codes are now erased.                                                                                                                                                                                                                                                                                                                                                                                                             NETWORK

                                                                                                                                                                                                                                                                                                                                                                                                                                                                                         SAL
NOTICE: To comply with FCC and/or Industry Canada (IC) rules, adjustment or modifications of this transceiver are prohibited. THERE ARE
                                                                                                                                                                                                                                                                                                                                                                         S T OP N       ET C O E




                                                                                                                                                                                                                                                                                                                                                                                                        O F       ON




NO USER SERVICEABLE PARTS.                                                                                                                                                                                                                                                                                                                                               OVE
                                                                                                                                                                                                                                                                                                                                                                         A E
                                                                                                                                                                                                                                                                                                                                                                                               S


                                                                                                                                                                                                                                                                                                                                                                                                   2
                                                                                                                                                                                                                                                                                                                                                                                                         5
                                                                                                                                                                                                                                                                                                                                                                                                                 0



                                                                                                                                                                                                                                                                                                                                                                                                                         0
                                                                                                                                                                                                                                                                                                                                                                                                                                                                     D P




This device complies with Part 15 of the FCC rules and IC RSS-210. Operation is subject to the following two conditions: (1) this device may
                                                                                                                                                                                                                                                                                                                                                                                                                                                                          X
                                                                                                                                                                                                                                                                                                                                                                                                          F              0   N
                                                                                                                                                                                                                                                                                                                                                                                                                                              D
                                                                                                                                                                                                                                                                                                                                                                         T T S                                                                     C D S
                                                                                                                                                                                                                                                                                                                                                                                        T C A GN              G T M VN           CP RO   D                          S A O

                                                                                                                                                                                                                                                                                                                                                                                                                                                                      E E




not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired
                                                                                                                                                                                                                                                                                                                                                                                                                                                                  N E R




operation.
This Class B digital apparatus complies with Canadian ICES-003.                                                                                                                                                                                                                                                                                                                                     5                                                                 L
                                                                                                                                                                                                                                                                                                                                                                                                                                                                            W




                                                                                                                                                                                                                                                                                                                                                                             A T
                                                                                                                                                                                                                                                                                                                                                                                        O ER
                                                                                                                                                                                                                                                                                                                                                                                                                                                                      O
                                                                                                                                                                                                                                                                                                                                                                                                                                                                          W
                                                                                                                                                                                                                                                                                                                                                                                                                                                                            O




AVIS : Les règles de la FCC et/ou d’Industrie Canada (IC) interdisent tout ajustement ou toute modification de ce récepteur. IL N’EXISTE
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                O




AUCUNE PIÈCE SUSCEPTIBLE D’ÊTRE ENTRETENUE PAR L’UTILISATEUR.
                                                                                                                                                                                                                                                                                                                                                                                                                 S L R/
                                                                                                                                                                                                                                                                                                                                                                                                                 C A G R
                                                                                                                                                                                                                                                                                                                                                         BR   R   WT E B U R D     BR   R   WT YE       UR D


                                                                                                                                                                                                                                                                                                                                                                                                                                               D   E ET    L RM




Cet appareil est conforme aux dispositions de la partie 15 du règlement de la FCC et de la norme IC RSS-210. Son utilisation est assujettie
aux deux conditions suivantes : (1) ce dispositif ne peut causer des interférences nuisibles, et (2) ce dispositif doit accepter toute
interférence reçue, y compris une interférence pouvant causer un fonctionnement non souhaité.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.

                                                                                                                                               27


OPERATION                                                                     MANUAL RELEASE + RESET BUTTON + REMOTE CONTROL + PARTY MODE

MANUAL RELEASE
In case of a power failure, the operator can be disengaged from the gate. With an
operator, the release action may sometimes feel stiff/jerky, which is normal and has
no effect on function.
RELEASE

1     Insert the key into the lock.

2     Turn the key counter-clockwise 180°.

3     Turn the release lever counter-clockwise 180°.

Operator is in manual mode and the gate can be opened and closed manually.
ENGAGE

1     Turn the release lever clockwise 180°. This engages the motor.

2     Turn the key clockwise 180°. This locks the release lever.

3     Remove the key and store in a safe place.

The operator is now engaged.


RESET BUTTON
The reset button is located on the side of the control box and serves several functions.                                                   !
Pressing the reset button will stop a moving gate during a normal open/close cycle,
like a stop button. The operator does not need to be reset after doing this.
   PROGRAMMING LIMITS RESET
   If a mistake is made while programming the limits press the reset button to
   start over.
                                                                                               A
   OPERATOR ALARM                                                                                                                                      B
   If a contact sensor detects an obstruction twice consecutively the alarm will sound                                !
   (up to 5 minutes) and the operator will need to be reset.
   When the inherent force of the operator (RPM/current sensor) detects the
   following (twice consecutively) the alarm will sound (up to 5 minutes) and the
                                                                                                   C                                             D
   operator will need to be reset:
   A. The operator arm or gate is incorrectly installed.
                                                                                                                       !
   B. The gate does not meet specifications.                                                                                                                           !

   C. Gate hinges are too tight or broken and the gate is not moving freely.
   D. The gate is moving and a car pushes the gate.                                                E                                             F
   E. A foreign object is on the gate frame while the gate is moving.
   F. The gate hits the driveway, curb or other, and gets stuck or bent in an                                          !                                           !
       awkward position.
   Remove any obstructions. Press the reset button to shut off the alarm and reset
   the operator. After the operator is reset, normal functions will resume.
   The operator alarm will beep 3 times with a command if the battery is low.

REMOTE CONTROL                                                                                     PARTY MODE
Once the remote control has been programmed the operator will operate as follows:                  If the Timer-to-Close feature is enabled and you would like the gate to remain open,
When gate is in the closed position, activation of the remote control button will open             open the gate fully, then press the reset button. The next command given by a
the gate. During the open cycle another activation of the remote control will stop the             LiftMaster remote control or SINGLE BUTTON on the control board will close the gate
gate and the next activation of the remote control will close the gate.                            and return the operator to normal operation.
When the gate is in the open position, activation of the remote control button will                NOTE: If an alternative radio receiver is wired to the operator, the receiver must be
close the gate. If the remote control is activated while the gate is closing, the gate will        wired to the SINGLE BUTTON and CTRL PWR inputs.
stop and the next activation will open the gate.
                                                                                              28


MAINTENANCE                                                                                                                     MAINTENANCE CHART + BATTERIES

MAINTENANCE CHART
Disconnect all power (AC, solar, battery) to the operator before servicing. The operator's AC Power switch ONLY turns off AC power to the control board and
DOES NOT turn off battery power. ALWAYS disconnect the batteries to service the operator.

  DESCRIPTION                               TASK                                                                                       CHECK AT LEAST ONCE EVERY
                                                                                                                              MONTH            6 MONTHS             3 YEARS
  Entrapment Protection Devices             Check and test for proper operation                                                    X
  Warning Signs                             Make sure they are present                                                             X
  Manual Release                            Check and test for proper operation                                                                       X
  Gate                                      Inspect for wear or damage                                                             X
  Accessories                               Check all for proper operation                                                                            X
  Electrical                                Inspect all wire connections                                                                              X
  Mounting Hardware                         Check for tightness                                                                                       X
  Operator                                  Inspect for wear or damage                                                                                X
  Batteries                                 Replace                                                                                                                      X
NOTES:
• Severe or high cycle usage will require more frequent maintenance checks.
• It is suggested that while at the site voltage readings be taken at the operator. Using a digital voltmeter, verify that the incoming voltage to the operator it is within ten
  percent of the operator’s rating.




BATTERIES
Batteries will degrade over time depending on temperature and usage. For best
performance, the batteries should be replaced every 3 years. Use only LiftMaster
part 29-NP712 for replacement batteries. The operator comes with two 7AH
batteries.
Two 33AH (A12330SGLPK) may be used in place of the 7AH batteries for a Large
Metal Control Box solar installation. A Battery tray (Model K10-36183) is required
for the 33AH application.
The batteries contain lead and need to be disposed of properly. Batteries do not
perform well in extremely cold temperatures.
The operator alarm will beep 3 times with a command if the battery is low.




                                                                                        29


ADDITIONAL FEATURES                                                                                                                                                         CONTROL BOARD OVERVIEW

CONTROL BOARD OVERVIEW
SET OPEN Button                   The SET OPEN button sets the OPEN limit. See Adjust Limits section.
SET CLOSE Button                  The SET CLOSE button sets the CLOSE limit. See Adjust Limits section.
MOVE GATE Button                  The MOVE GATE buttons will either open or close the gate when the operator is in Limit setting mode. See Adjust Limits section.
BIPART DELAY Switch               The Bipart delay switch is used only for dual gates. See Bipart Delay section.
LEARN Button                      The LEARN button is for programming remote controls and the network.
TIMER-TO-CLOSE dial               The TIMER-TO-CLOSE (TTC) dial can be set to automatically close the gate after a specified time period. The TTC is factory set to OFF. If the
                                  TTC is set to the OFF position, then the gate will remain open until the operator receives another command from a control. Rotate the
                                  TIMER-TO-CLOSE dial to the desired setting. The range is 0 to 180 seconds, 0 seconds is OFF.
                                  NOTE: Any radio command, single button control, or CLOSE command on the control board prior to the TTC expiring will close the gate.
                                  The TTC is reset by any signals from the open controls, loops, close edges, and close photoelectric sensors (IR’s).
REVERSAL FORCE dial               The REVERSAL FORCE dial adjusts the force. See Force Adjustment section.
TEST BUTTONS                      The TEST BUTTONS will operate the gate (OPEN, STOP and CLOSE).
STATUS LEDs                       The STATUS LEDs are diagnostic codes for the operator. See Status LED Chart in the Troubleshooting section.

                          SET OPEN        SET CLOSE
                                                                                                                                                         Open
                                                                                           XMITTER
                                                                                                                                                         Close
                                                                                                                                                                                A
                                                                                                                                                                                           3 Button
                                                                                                                                                                                B
                                                                                                                 OPEN

                                                                                           NETWORK
                                                             OFF         ON
                                                                                                                                  SBC                    Stop                              Station
                                                   PRESS &
                                                   RELEASE
                                                                                                                                                         Com                    C
                                                                                                                 CLOSE




                                                  TO BEGIN
                                                                                                                                                         Fire Dept
                                                                   (SECONDS)
                                                  LIMIT               10                                                       “FIRE

                                                                                                                                                                                D
                                                  SETUP                                                                        DEPT ”
                                                                                                                                                                                           Fire Dept.
                         MOVE                          1                                                                        OPEN                     Com
                         GATE
                                                       2
                                                             5                  60
                                                                                                                                                         Exit
                                                                                                                 STOP




                                                             OFF               180 MIN
                                                                                                                                 EXIT                    Com                    E          Exit Loop
                                                                                                MAX
                                                                                                                                                         Shadow
                                                                                                                                                                                F
                                         INPUT POWER             TIMER               BATT LOW         DIAGNOSTIC
                        STATUS:                                                                                                                                                            Shadow Loop
                                         BATT CHARGING           GATE MOVING         ACC PWR OVLD       CODES                SHADOW                      Com
                                                                                                                              CLOSE
                                                                                                                               EYES/                     Interrupt
                                                                                                                                                                                G
                                                                                                                                        -




                                                                                                                           INTERRUPT                     Com                               Interrupt Loop
                                                                                                                                        +




                                                                                                                                                         Open (+)                          Open Direction
                                                                                                                                                         Open (-)               H          Safety
                                                                                                                                                         Close (+)                         Close Direction
                                                                                                                                                                                I
                                                                                                                                      +




                                                                                                                                                         Close (-)                         Safety
                                                                                                                                      -




                                                                                                                                                         Comm Link Data A

                                                                                                                                                         Comm Link Data B       J          Comm Link
                                                                                                                                   J5




                                                                                                                                                         Lock N.C. (Maglock)
                                                                                                                                                                                K
                                                                                                                                        N.C.




                                                                                                                                                                                           Mag and
                                                                                                                                                         Com
                                                                                                                                                                                           Solenoid Lock
                                                                                                                                        N.O. COM




                                                     J15                                                                       LOCK                      Lock N.O. (Solenoid)   L
                                                                                                                                                         Com (-)                            Acc. Power
                                                                                                                                                                                M
                            +                 +
                                                                                                                                                                                    Switched ON with gate motion. Always ON with
                                                                                                                                       SW.
                                                                                                                                         -
                                                                                                                                ACCESSORY




                                BATT      DC
                                                                                                                                                         AccPower +24 Vdc
                                          POWER
                                                                                                                                                                                    expansion board connected. Switches Off to save
                                                                                                                                  POWER
                                                                                                                                     +




                                                                                                                                                         Com (-)                    battery power if expansion board disconnected.
                                                                                                                                                         AccPower +24 Vdc       N
                                                                                                                                  -
                                                                                                                                ON




                                                                                                                                                                                    Always ON
                                                                                                                                        +




                                                                                                                                        CLASS 2 SUPPLY
                                                                                                                                        24 VOLTS
                                                                                                                                              BOARD
                                                                                                                                               EXP.




                                                                       SOLAR /
                                                                       CHARGER                                                GROUND
           BR GRN WT YE BLU RED        BR GRN WT YE BLU RED                +


                                                                                                      ID RESET     ALARM




                                                                                                         30


ADDITIONAL FEATURES                                                                             ACCESSORY FEATURES ON CONTROL BOARD

ACCESSORY FEATURES ON CONTROL BOARD

  A    Open Input (& common)
       (3-Button Control Station, 4 terminals
                                                Open command - opens a closed gate.
                                                Hard open (maintained switch overrides external safeties and resets alarm condition)
       total)                                   If maintained, pauses Timer-to-Close at OPEN limit.
                                                Opens a closing gate and holds open an open gate (within line-of-sight).


  B    Close Input (& common)                   Close command - closes an open gate.
       (3-Button Control Station, 4 terminals   Hard close (maintained switch overrides external safeties and resets alarm condition within line-of-sight)
       total)

  C    Stop Input (& common)                    Stop command - stops a moving gate.
       (3-Button Control Station, 4 terminals   Hard stop (maintained switch overrides Open and Close commands and resets alarm condition)
       total)                                   If maintained, pauses Timer-to-Close at OPEN limit.
                                                Overrides Open and Close commands (within line-of-sight).


  D    Fire Dept Open Input                     Acts as hard open.
       (2 terminals)                            Maintained input overrides (ignores) external safeties (photoelectric sensor and edge), pauses Timer-to-Close
                                                momentary input logic as single button control and safeties remain active, re-enables Timer-to-Close.


  E    Exit Loop Input                          Open command - opens a closed gate.
       (2 terminals)                            Soft open (maintained switch does not override external safeties and does not reset alarm condition)
                                                If maintained, pauses Timer-to-Close at OPEN limit.
                                                Opens a closing gate and holds open an open gate.


  F    Shadow Loop Input                        Loop detector connection when loop is positioned under gate.
       (2 terminals)                               - Holds open gate at open limit
                                                   - Disregarded at CLOSE limit and during gate motion
                                                   - Pauses Timer-to-Close at OPEN limit


  G    CLOSE EYES/Interrupt Loop Input          CLOSE EYES/Interrupt Loop detector connection when loop is along the side of the gate.
       (2 terminals)                                - Holds open gate at open limit
                                                    - Stops and reverses a closing gate to open limit
                                                    - Pauses Timer-to-Close at OPEN limit
                                                Close Direction Photoelectric Sensors, IR, or Infra-red detector wired to CLOSE EYES Input, disregarded during gate
                                                opening.
                                                Pulsed Photoelectric Sensors = monitored device putting out a pulse train when unblocked.
                                                Photoelectric Sensors, IR, Infra-red detector, contact opens fully with obstruction.


  H    Close Edge                               Close Direction Edge Sensor to Close Safety Input, disregarded during gate opening
       (2 terminals)

  I    Open Eyes/Edge                           Open Direction Photoelectric Sensors, IR, Infra-red detector wired or Edge Sensor to Close Entrapments Input,
       (2 terminals)                            disregarded during gate closing,
                                                Pulsed Photoelectric Sensors = monitored device putting out a pulse train when unblocked.
                                                Photoelectric Sensors, IR, Infra-red detector, edge sensor = normally open contact, contact reverses for 2 seconds
                                                with obstruction.


  J    Comm Link                                Commercial Link (two wires) - connects two operators together (primary-secondary wired connection)
       (2 terminals)

  K    Lock Outputs: Maglock                    Relay contact output, Normally - closed (N.C.) output for maglocks
       (2 terminals, N.C. and COM)              Relay activates prior to motor activation and during motor run. Relay is off when motor is off.


  L    Solenoid Lock & Common                   Normally - open (N.O.) output for solenoid locks
       (2 terminals, N.O. and COM)              Relay activates prior to motor activation and during motor run. Relay is off when motor is off.


  M    Accessory Power Out                      24 Vdc voltage out to power accessories, will turn off when gate is not in motion to save battery power
       Switched, (2 terminals)                  Always on if Expansion Board is connected.


  N    Accessory Power Out                      24 Vdc voltage out to power accessories, always ON
       Un-switched, (2 terminals)




                                                                  31


ADDITIONAL FEATURES                                                                                                                                                           EXPANSION BOARD OVERVIEW
EXPANSION BOARD OVERVIEW


 To AVOID damaging the circuit board, relays or accessories, DO NOT connect more than 42 Vdc (32 Vac) to the AUX relay contact terminal blocks.
QUICK CLOSE Switch                        OFF: No change to the gate's normal operation.
                                          ON: When CLOSE EYES/Interrupt loop is deactivated it causes an opening or a stopped gate to close (ignores the Timer-to-Close).
AC FAIL OPEN/BATT Switch                  OPEN: Loss of AC power will cause gate to immediately OPEN and remain OPEN until AC power is restored (enabling the Timer-to-Close).
                                          BATT: With loss of AC power, gate will remain in present position and operator is powered from batteries.
LOW BATT/EXIT LOOP FAIL                   • When AC power is OFF and battery voltage is low the gate will latch at a limit until AC power is restored or batteries voltage increases.
Switch                                    • Option select switch set to OPEN forces gate to latch at the OPEN limit if it is at the OPEN limit or on next open command until AC power is
                                            restored or battery voltage increases.
                                          • Option select switch set to CLOSE forces gate to latch at CLOSE limit if at CLOSE limit or on next CLOSE command until AC power restored or
                                            battery voltage increases.
                                          • Constant pressure on a hard command input overrides to open or close the gate.
                                          • Low battery detect point = 22 V
                                          • When set to OPEN, if the EXIT plug-in loop detector detects a fault, then the gate will open and remain open until fault is cleared. When set to
                                            CLOSE, then plug-in EXIT loop detector faults are ignored (EXIT loop is faulted and inoperative).
ANTI-TAIL OPEN/CLOSE                      OFF: When CLOSE EYES/Interrupt loop is activated it causes a closing gate to stop and reverse.
SELECTION switch                          ON: When CLOSE EYES/Interrupt loop is activated it causes a closing gate to pause. Once the vehicle is clear the gate will continue to close.
AUX RELAY switches                        Set the AUX RELAY switches as needed to obtain the desired function:
 AUX RELAY             SWITCH                                       AUX RELAY 1                                                                                               AUX RELAY 2
  SETTING             SETTINGS
                      1     2     3
Off (no feature OFF OFF OFF                      Relay always off. Use this Aux Relay setting to conserve                                   Relay always off. Use this Aux Relay setting to conserve battery power.
   selected)                                                         battery power.
   Open Limit        OFF OFF ON          Energizes at open limit. Use with SAMS (Sequenced Access Management                                      Energizes when at open limit. Use with SAMS (Sequenced Access
    Switch                                                  System, jointly with barrier gate)                                                            Management System, jointly with barrier gate)
   Close Limit       OFF ON OFF          Energizes when not at close limit. Connect “Gate Close/Secure” indicator                              Energizes when not at close limit. Connect “Gate Not Closed/Secure”
     Switch                                                             (e.g. light).                                                                                 indicator (e.g. light).
  Gate Motion        OFF ON ON            Energizes when motor is on (gate in motion). Connect “Gate In Motion”                             Energizes when motor is on (gate in motion). Connect “Gate In Motion”
                                                        indicator (e.g. warning light or sounder).                                                        indicator (e.g. warning light or sounder).
   Pre-Motion        ON OFF OFF Energizes 3 seconds before gate motion and remains energized during gate                                                                        Not used.
      Delay                     motion. Connect “Gate In Motion” indicator (e.g. warning light or sounder).
     Power           ON ON OFF          Energizes when AC power or solar power is present. There is approximately                               Energizes when on battery power. There is approximately a 10-12
                                               a 10-12 second delay before relay cutoff, after AC shutdown.                                            second delay before relay cutoff, after AC shutdown.
     Tamper          ON OFF ON           Energizes if gate is manually tampered with by being pushed off of close                          Energizes if gate is manually tampered with by being pushed off of close
                                                         limit. Connect alert (e.g. light or sounder).                                                     limit. Connect alert (e.g. light or sounder).
 Cycle Quantity      ON ON ON                 The OPEN, CLOSE, and STOP LEDs will blink out the cycle count                                                                     Not used.
   Feedback*                                                         See below.
CYCLE COUNT
* First, note the current Aux Relay switch positions. To
  determine the actual cycles that the gate operator has
  run (in thousands), set all three Aux Relay switches to
                                                                                                                                                                                                           Single
  the ON setting for Aux Relay 1. The Expansion Board’s                                                                                                                                                    Button
                                                                                                                                                                                            SBC
  OPEN, CLOSE, and STOP LEDs will blink out the cycle                                                                                                                                                      Control
  count, with OPEN LED blinking 1000’s, CLOSE LED blink
                                                                                                                                                                                            Com      D     Station
                                                                                                                                                                                            Open
  10,000’s, STOP LED blinking 100,000’s, and                                                                                                                                                Close    A     3-Button
  simultaneously all three LED’s blink 1,000,000’s (e.g.                                                                                                                                    Stop     B     Control
  Open blinks 3 times, Close blinks 6 times, and Stop                                                                                                                                       Com      C     Station

  blinks once. Cycle count is 163,000.). Cycle count
  displayed is between 1,000 and 9,999,000 cycles.
  After servicing, set Aux Relay switches back to their
                                                                            Shadow Loop




                                                                                                                                    AUX Relay 1 N.O.



                                                                                                                                                       AUX Relay 2 N.O.

                                                                                                                                                       AUX Relay 2 N.C.
                                                                                                                                    AUX Relay 1 N.C.
                                                                                              Interrupt Loop


                                                                                                               Exit Loop




  appropriate positions. Cycle count cannot be reset or                 F                                                  E    H
                                                                                                                                         Com




                                                                                                                                                                          I
                                                                                                                                                            Com




  changed. If under 1,000 cycles the Open, Close, and
  Stop LEDs will turn on for 10 seconds, then turn off.
                                                                                          G                                32


ADDITIONAL FEATURES                                                                                                             ACCESSORY FEATURES ON EXPANSION BOARD

ACCESSORY FEATURES ON EXPANSION BOARD

    A         Open Input (& common)
              (3-Button Control Station,
                                                                  Open command - opens a closed gate.
                                                                  Soft close (maintained switch does not override external safeties and does not reset alarm condition)
              4 terminals total)                                  If maintained, pauses Timer-to-Close at OPEN limit.
                                                                  Opens a closing gate and holds open an open gate.


    B         Close Input (& common)                              Close command - closes an open gate.
              (3-Button Control Station,                          Soft close (maintained switch does not override external safeties and does not reset alarm condition)
              4 terminals total)

    C         Stop Input (& common)                               Stop command - stops a moving gate.
              (3-PB station, 4 terminals total)                   Hard stop (maintained switch overrides Open and Close commands and resets alarm condition)
                                                                  If maintained, pauses Timer-to-Close at OPEN limit.
                                                                  Overrides an Open or Close command.


   D          Single Button Control, SBC                          Gate command sequence - Open, Stop, Close, Stop, ...
              (2 terminals)                                       Soft open (maintained switch does not override external safeties and does not reset alarm condition)


   E          Exit Loop Input                                     Loop wire connection for plug-in loop detector when loop is inside secured area near gate.
              (2 terminals)                                       Open command - opens a closed gate.
                                                                  Soft open (maintained switch does not override external safeties and does not reset alarm condition)
                                                                  If maintained, pauses Timer-to-Close at OPEN limit.
                                                                  Opens a closing gate and holds open an open gate.


    F         Shadow Loop Input                                   Loop wire connection for plug-in loop detector when loop is along side gate.
              (2 terminals)                                          - Holds open gate at open
                                                                     - Disregarded at Close limit and during gate motion
                                                                     - Pauses Timer-to-Close at Open Limit


   G          Interrupt Loop Input                                Loop wire connection for plug-in loop detector when loop is positioned under gate.
              (2 terminals)                                          - Holds open gate at open
                                                                     - Stops and reverses a closing gate
                                                                     - Pauses Timer-to-Close at Open Limit


   H          AUX Relay #1                                        Normally - open and normally - closed relay contacts to control external devices,
                                                                  Function of relay contact activation determined by AUX Relay #1 option switch settings. (For connection of Class
                                                                  2, low voltage (<32 V), DC or AC, max 5 Amps, power sources only)


     I        AUX Relay #2                                        Normally-open and normally-closed relay contacts to control external devices,
                                                                  Function of relay contact activation determined by AUX Relay #2 option switch settings. (For connection of Class
                                                                  2, low voltage (<32 V), DC or AC, max 5 Amps, power sources only)




         AUX RELAY WIRING EXAMPLE                                                                 SAMS WIRING WITH RELAYS NOT ENERGIZED

                                                                                                            Main Board
                                                                                                                                  SET OPEN         SET CLO E

                                                                                                                                                                                              XM T R

                                                                                                                                                                                              N   W RK
                                                                                                                                                                                                                                               Exit Input     Barrier Arm Operator
                                                                                                                                                                          FF       ON


                                                                                                                                                            E A E




                                           Class 2 Power Source
                                                                                                                                                                               S CO D )
                                                                                                                                                            IM T                  0
                                                                                                                                                            E UP
                                                                                                                                 MOVE



                                                                                                                                                                                                                                                                     C
                                                                                                                                 G TE
                                                                                                                                                               2
                                                                                                                                                                      5                   6




                                           (32 V max, 5 A max)                                                                   TATUS
                                                                                                                                                  N UT P WER
                                                                                                                                                   A T CH RG NG
                                                                                                                                                                           T MER
                                                                                                                                                                           GA E M




                                                                                                                                                                                                                                                                         Auxiliary
                                                                                                                                                                                                                                                                         Command
                                            +              —                                                                                                                                                                                                        NO
                             N.C.
                             COM
                                                                                                                                                             J 5




  Aux Relay
                                                                                                                                      +                +
                                                                                                                                                                                                                            CC SS RY
                                                                                                                                                                                                                                 SW




                                                                                                                                          A T      DC
                                                                                                                                                   P WER
                                                                                                                                                                                                                             P WER
                                                                                                                                                                                                                            N




                             N.O.
                                                                                                                                                                                                                                       B ARD
                                                                                                                                                                                                                                         XP




                                                                                                                                                                                                                                                                                     Access Device
                                                                                                                                                                                  SO AR /
                                                                                                                                                                                  CH RG R                                   RO ND
                                                                                                                   BR G N WT YE B U   ED        BR G N WT     E     LU ED


                                                                                                                                                                                                         ID R S T   A A M




                                                                                                                                Expansion Board                                                                                                Shadow Input


                                                Warning Light




                                                                             Dipswitch settings for AUX Relay 1:
                                                                             1-OFF, 2-OFF, 3-ON
                                                                                                                                                                                                                AUX Relay 1


                                                                                    33


ADDITIONAL FEATURES                                                                                                                    GATE OPERATOR SETUP EXAMPLES

GATE OPERATOR SETUP EXAMPLES
The following are example setups for the gate operator. Your specific site requirements may be different. Always setup the operator system to the site requirements, including
all necessary secondary entrapment protection systems.
RESIDENTIAL SMALL: One to four residential homes sharing a gated entrance/exit, allowing vehicle access trumps security concerns
RESIDENTIAL LARGE: A residential community (more than four homes) having one or more gated entrances/exits, allowing vehicle access trumps security concerns
COMMERCIAL: Business site where security (gate closed) is important
INDUSTRIAL: Large business site where security is required

 Setting                            RESIDENTIAL SMALL                     RESIDENTIAL LARGE                     COMMERCIAL                            INDUSTRIAL
 Quick Close switch setting         Normally set to OFF. Normal gate      Normally set to OFF. Normal gate      Normally set to OFF. Normal gate      Set to ON, so that gate closes
                                    close (timer or control).             close (timer or control).             close (timer or control).             immediately after vehicle passes
                                                                                                                                                      interrupt loop.
 AC Fail Open switch setting Normally set to BATT. Run on                 Normally set to BATT. For local       Normally set to BATT. Run on          Normally set to BATT. Run on
                                    battery if AC power fails.            jurisdiction requirement, set to      battery if AC power fails.            battery if AC power fails.
                                                                          OPEN so that gate immediately
                                                                          opens upon AC power fail.

 Low Battery switch setting Normally set to OPEN. If powered              Normally set to OPEN. If powered      Normally set to CLOSE. If powered     Normally set to CLOSE. If powered
                                    from battery and battery is low,      from battery and battery is low,      from battery and battery is low,      from battery and battery is low,
                                    gate stays open.                      gate stays open.                      gate stays close.                     gate stays close.
 Anti-Tail switch setting           Normally set to OFF. Interrupt loop   Normally set to OFF. Interrupt loop   Set to ON. In attempt to prevent      Set to ON. In attempt to prevent
                                    reverses a closing gate.              reverses a closing gate.              vehicle tail-gating, interrupt loop   vehicle tail-gating, interrupt loop
                                                                                                                pauses a closing gate.                pauses a closing gate.
 Bipart Delay switch setting For DUAL-GATE site, set to ON for            For DUAL-GATE site, set to ON for     For DUAL-GATE site, set to ON for     For DUAL-GATE site, set to ON for
                                    gate that delays upon opening         gate that delays upon opening         gate that delays upon opening         gate that delays upon opening
 Aux Relay Out – Open               Typically not required.               Use with SAMS (Sequence Access        1) Use with SAMS (Sequence Access     1) Use with SAMS (Sequence Access
 Limit Switch                                                             Management System)                       Management System)                    Management System)
                                                                                                                2) Connect “Gate Open” indicator      2) Connect “Gate Open” indicator
                                                                                                                   (e.g. light)                          (e.g. light)
 Aux Relay Out – Close              Typically not required.               Typically not required.               Connect “Gate Close/Secure”           Connect “Gate Close/Secure”
 Limit Switch                                                                                                   indicator (e.g. light)                indicator (e.g. light)

 Aux Relay Out – Gate               Attach alert signal (audible or       Attach alert signal (audible or       Attach alert signal (audible or       Attach alert signal (audible or
 Motion                             visual alert system)                  visual alert system)                  visual alert system)                  visual alert system)

 Aux Relay Out – Pre-               Attach alert signal (audible or       Attach alert signal (audible or       Attach alert signal (audible or       Attach alert signal (audible or
 Motion Delay                       visual alert system)                  visual alert system)                  visual alert system)                  visual alert system)

 Aux Relay Out – Power              Attach visual alert to know when      Attach visual alert to know when      Attach visual alert to know when      Attach visual alert to know when
                                    system is charging batteries (i.e.    system is charging batteries (i.e.    system is charging batteries (i.e.    system is charging batteries (i.e.
                                    not running on batteries)             not running on batteries)             not running on batteries)             not running on batteries)
 Aux Relay Out – Tamper             Attach alert signal (audible or       Attach alert signal (audible or       Attach alert signal (audible or       Attach alert signal (audible or
                                    visual alert system) to indicate if   visual alert system) to indicate if   visual alert system) to indicate if   visual alert system) to indicate if
                                    gate is manually tampered with by     gate is manually tampered with by     gate is manually tampered with by     gate is manually tampered with by
                                    being pushed off of close limit       being pushed off of close limit       being pushed off of close limit       being pushed off of close limit
 Cycle Quantity Feedback            Use during servicing only to          Use during servicing only to          Use during servicing only to          Use during servicing only to
                                    determine operator cycles             determine operator cycles             determine operator cycles             determine operator cycles
 Fire Dept Open input               Typically not required.               Connect emergency access system     Typically not required.                 Typically not required.
                                                                          (Knox box switch, SOS system, etc.)




                                                                                           34


ADDITIONAL FEATURES                                                                                                          LIMIT SETUP WITH A REMOTE CONTROL

LIMIT SETUP WITH A REMOTE CONTROL
To set the limits using a remote control, first you will need a 3-button remote control that has been programmed for OPEN, CLOSE, and STOP. Refer to the Programming
section.

INITIAL LIMITS AND FORCE ADJUSTMENT
For dual gate applications the limits will have to be set for each
operator. The gate MUST be attached to the operator before setting the
                                                                                                                                                                      ET OP N SET C OSE

                                                                                                                                                                                                                                 R

                                                                                                                                                                                                                           E W R
                                                                                                                                                                                               O F         O



                                                                                                                                                                                        MT            10                                         “ RE




limits and force.
                                                                                                                                                                                        TU                                                       DE T
                                                                                                                                                                 MO E                    1




                                                                                                                                         B
                                                                                                                                                                 G TE


                                                                                                                SET OPEN SET CLOSE
                                                                                                                                                                                         2
                                                                                                                                                                                               5               6

                                                                                                                                                                                                                                                      E I
                                                                                                                                                                                               F               0 M



                                                                                                                                         D
                                                                                                                                                                               N UT OW R             M R             AT LOW          A NO T
                                                                                                                                                                 TA US                                                               CO ES
                                                                                                                                                                                A T CH R I G         TE M V NG       CC P R OV                   H
                                                                                                                                                                                                                                                 C O E
                                                                                                                                                                                                                                                   Y S

                                                                                                                                                                                                                                              N ER




Ensure the gate is closed.                                                                                                                F


1




                                                                                                                                                                                                                                                        5
    Press the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting
                                                                                                                                                                                         15




                                                                                                                                                                                                                                                     CC S ORY
                                                                                                                                                                                                                                                            W
                                                                                                                                                                       BA T
                                                                                                                                                                                P WER




                                                                                                                                                                                                                                                       OWER
    mode.




                                                                                                                                                                                                                                                     N
                                                                                                                                                                                                                                                                XP
                                                                                                                                                                                                           OL R /
                                                                                                                                                                                                           HA GER
                                                                                                                                                    BR G N WT E B U    ED     R G N WT YE B U R D




2 Press and hold the OPEN or CLOSE button on the remote control until the gate
  reaches the desired open position. The gate can be jogged back and forth using
    the OPEN and CLOSE buttons on the remote control.
                                                                                                                3-Button Remote Control programmed for OPEN, CLOSE, and STOP


3 Once the gate is in the desired open position, press and release the STOP button
  on the remote control.


4 Press
  limit.
         and release the OPEN button on the remote control again to set the open



5 Press and hold the CLOSE or OPEN button on the remote control until the gate
  reaches the desired close position. The gate can be jogged back and forth using
    the OPEN and CLOSE buttons on the remote control.


6 Once the gate is in the desired close position, press and release the STOP button
  on the remote control.


7 limit.
    Press and release the CLOSE button on the remote control again to set the close



8 Cycle the gate open and close. This automatically sets the force.
When limits are set properly the operator will automatically exit limit setting mode.

ADJUST THE LIMITS

If the limits have already been set the operator will exit the limit setting mode after resetting each limit.
Set the Close Limit Only                                                                     Set the Open Limit Only

1   Press the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting
    mode.
                                                                                             1   Press the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting
                                                                                                 mode.


2 desired close position. The gate can be jogged back and forth using the OPEN
    Press and hold the CLOSE button on the remote control until the gate reaches the
                                                                                             2 Press and hold the OPEN button on the remote control until the gate reaches the
                                                                                               desired open position. The gate can be jogged back and forth using the OPEN
    and CLOSE buttons on the remote control.                                                     and CLOSE buttons on the remote control.


3 Once the gate is in the desired close position, press and release the STOP button
  on the remote control.                                                            3 Once the gate is in the desired open position, press and release the STOP button
                                                                                      on the remote control.

    Press and release the CLOSE button on the remote control again to set the close
4 limit.                                                                                     4 Press
                                                                                               limit.
                                                                                                      and release the OPEN button on the remote control again to set the open


When the close limit is set properly the operator will automatically exit limit setting    When the open limit is set properly the operator will automatically exit limit setting
mode.                                                                                   35 mode.


TROUBLESHOOTING                                                                                                                                                                             CONTROL BOARD LEDS

CONTROL BOARD LEDS
The control board is equipped with many LEDs that have a variety of functions. The control board LEDs indicate the status of the operator, assist with programming, and
diagnose potential problems with the operator.




                                           LIMIT SETUP LEDS                                                GREEN XMITTER LED                                     DIAGNOSTIC CODES LEDS



                                                      SET OPEN SET CLOSE

                                                                                                                               XMITTER




                                                                                                                                                    OPEN
                                                                                                                               NETWORK
                                                                                             OFF         ON
                                                                                                                                                                     SBC

STATUS LEDS                                                                        PRESS &
                                                                                   RELEASE
                                                                                                                                                                                                 INPUT LEDS




                                                                                                                                                    CLOSE
                                                                                  TO BEGIN         (SECONDS)
                                                                                  LIMIT               10                                                          “FIRE
                                                                                  SETUP                                                                           DEPT.”
                                                     MOVE                              1                                                                           OPEN
                                                     GATE
                                                                                       2
                                                                                             5                  60




                                                                                                                                                    STOP
                                                                                                                                                                    EXIT
                                                                                             OFF               180 MIN            MAX
                                                                         INPUT POWER             TIMER                BATT LOW           DIAGNOSTIC
                                                    STATUS:                                                                                CODES
                                                                         BATT CHARGING           GATE MOVING          ACC PWR OVLD                              SHADOW
                                                                                                                                                                 CLOSE
                                                                                                                                                                  EYES/




                                                                                                                                                                           -
                                                                                                                                                              INTERRUPT




                                                                                                                                                                         +
                                                                                                                                                                         - +
                                                                                                                                                                      J5
                                                                                                                                                                           N.C.
                                                                                                                                                                           N.O. COM


                                                                                     J15                                                                          LOCK


                                                        +          -      -   +
                                                                                                                                                                          SW.
                                                                                                                                                                            -
                                                                                                                                                                   ACCESSORY




                                                            BATT          DC
                                                                          POWER
                                                                                                                                                                     POWER
                                                                                                                                                                     -  +
                                                                                                                                                                   ON
                                                                                                                                                                           +




                                                                                                                                                                           CLASS 2 SUPPLY
                                                                                                                                                                           24 VOLTS
                                                                                                                                                                                 BOARD
                                                                                                                                                                                  EXP.




                                                                                                       SOLAR /
                                                                                                       CHARGER                                                   GROUND
                                       BR GRN WT YE BLU RED            BR GRN WT YE BLU RED                +    -


                                                                                                                                         ID RESET     ALARM




                        LIMIT SETUP LEDS                                                                                                     GREEN XMITTER LED
 SET OPEN        SET CLOSE        OPERATOR MODE                        EXPLANATION                                   XMITTER LED                EXPLANATION
 LED             LED
                                                                                                                     OFF                        No remote control activity, normal operation.
 BLINKING        BLINKING         NORMAL MODE                          Limits are not set.
                                                                                                                     ON                         Programming mode active.
 OFF             OFF              NORMAL MODE                          Limits are set.
                                                                                                                     FAST                       Recognized remote control signal.
 BLINKING        BLINKING         LIMIT SETTING MODE                   Limits are not set.
                                                                                                                     FASTER                     Unrecognized remote control signal.
 BLINKING        ON               LIMIT SETTING MODE                   Open limit is not set.
                                                                                                                     FASTEST                    Remote controls are being erased.
 ON              BLINKING         LIMIT SETTING MODE                   Close limit is not set.
 ON              ON               LIMIT SETTING MODE                   Limits are set.
                                                                                                               36


TROUBLESHOOTING                                                                                                                       CONTROL BOARD LEDS

CONTROL BOARD LEDS
                                                             DIAGNOSTIC CODES LEDS
                  YELLOW DIAGNOSTIC LED                                                                        RED DIAGNOSTIC LED
# BLINKS      MEANING                CORRECTION                                        # BLINKS         MEANING              CORRECTION
1 BLINK       Low Power Mode         (not an error)                                    2 BLINKS         Current Sense        Motor control circuit fault, replace
2 BLINKS      ID resistor failure    Check ID resistor wiring, clear limit                                                   control board
                                     settings and reset limits                         3 BLINKS         FET Failure          Motor control circuit fault, replace
3 BLINKS      Exceeded Maximum       Check gate travel, if necessary adjust                                                  control board
              Run Timer              force setting                                     4 BLINKS         RAM Failure          Memory failure, replace control board
5 BLINKS      RPM (obstruction)      Check for obstruction, if necessary               5 BLINKS         Flash Memory         Memory failure, replace control board
                                     adjust force setting                                               Failure
6 BLINKS      Current (obstruction) Check for obstruction, if necessary                6 BLINKS         EEPROM Failure       Memory failure, replace control board
                                    adjust force setting                               7 BLINKS         Watchdog Failure     Controller failure, replace control
7 BLINKS      Position failure       Check gate travel, clear limit settings                                                 board
                                     and reset limits                                  8 BLINKS         Brownout             Check power harness or line voltage
12 BLINKS     Loop Error             One of the loops is in error. Refer to the        9 BLINKS         Fail                 Control Board failure
                                     loop detector to determine the error.
                                                                                       10-14 BLINKS Software Failure         Cycle power to the control board. If
                                                                                                                             continues replace control board.



                        STATUS LEDS                                                                                INPUT LEDS
INPUT POWER     OFF                  OFF state                                         OPEN INPUT       OFF                Input inactive
                ON                   AC charger or Solar power available                                ON                 Input active
BATT            OFF                  Not charging                                                       BLINK              Input active on other operator
CHARGING
                ON                   Trickle charge                                    CLOSE INPUT      OFF                Input inactive
                FAST BLINK           High current charge                                                ON                 Input active
                FASTER BLINK         Over voltage error                                                 BLINK              Input active on other operator
TIMER           OFF                  The timer is disabled                             STOP INPUT       OFF                Input inactive
                ON                   The timer is enabled                                               ON                 Input active
                MEDIUM BLINK         The timer is running                                               BLINK              Input active on other operator
                FAST BLINK           The timer is paused                               FIRE DEPT        OFF                Input inactive
                FASTER BLINK         The timer is cancelled                            INPUT
                                                                                                        ON                 Input active
GATE MOVING     OFF                  The gate is stopped                                                BLINK              Input active on other operator
                ON                   The gate is opening or closing                    SBC INPUT        OFF                Input inactive
                FASTEST BLINK        The operator is in E2                                              ON                 Input active
BATT LOW        OFF                  No battery error                                                   BLINK              Input active on other operator
                ON                   Battery low error                                 OPEN SAFETY      OFF                Input inactive
                SLOW BLINK           Battery dead error                                INPUT
                                                                                                        ON                 Input active
                MEDIUM BLINK         Battery over current error                                         BLINK              Input active on other operator
                FAST BLINK           Battery over voltage error                        CLOSE SAFETY     OFF                Input inactive
                FASTER BLINK         Extreme temperature error                         INPUT
                                                                                                        ON                 Input active
                FASTEST BLINK        Battery disconnected error                                         BLINK              Input active on other operator
ACC PWR OVLD OFF                     OFF state
                ON                   Accessory overload protector opened




                                                                                  37


TROUBLESHOOTING                                                                                                                        TROUBLESHOOTING CHART

FAULT                  POSSIBLE CAUSES                                        CORRECTIONS
Operator does not      a)   No power to control board                         a)   Check AC and battery power
run and diagnostic     b)   Open fuse                                         b)   Check fuses
LED not on.            c)   If on battery power only, low or dead batteries   c)   Charge batteries by AC or solar power or replace batteries
                       d)   Defective control board                           d)   Replace defective control board
Control board          a)   Check DIAGNOSTIC LEDs                             a)   Use Diagnostic code to identify issue
powers up, but         b)   Reset button is stuck                             b)   Check Reset button
motor does not run.    c)   Stop button active                                c)   Check Stop button is not “stuck on”
                       d)   If on battery power only, low or dead batteries   d)   Charges batteries by AC or solar power or replace batteries
                       e)   Open or Close input active                        e)   Check all Open and Close inputs for a “stuck on” input
                       f)   Entrapment Protection Device active               f)   Check all Entrapment Protection Device inputs for a “stuck on” sensor
                       g)   Vehicle loop detector or probe active             g)   Check all vehicle detector inputs for a “stuck on” detector
                       h)   Defective control board                           h)   Replace defective control board
Relay clicks with  a) Arm jammed or not connected                             a) Disengage the arm and ensure arm moves freely
command, but motor b) Defective motor or motor wires                          b) Inspect motor wires for open wire, shorted wires, damage, etc. Else, replace arm.
does not turn on.  c) Defective control board                                 c) Replace defective control board.
Arm moves, but         a) Arm does not extend or retract enough during        a) Disengage the arm and ensure arm moves freely
cannot set correct        travel                                              b) Examine the hinge point where the arm mounts to the gate post. Make sure that the arm
limits.                b) Arm is interfering with mounting bracket               housing does not hit or interfere with the gate post or mounting bracket. Correct as
                       c) Gate is too difficult to move                          necessary.
                                                                              c) Disconnect arm from gate and move gate manually. Gate must move easily and freely
                                                                                 through its entire range, limit-to-limit. Repair gate as needed.
Gate does not fully    a) Arm does not extend or retract enough during        a) Disengage the arm and ensure arm moves freely
open or fully close       travel                                              b) Examine the hinge point where the arm mounts to the gate post. Make sure that the arm
when setting limits.   b) Arm is interfering with mounting bracket               housing does not hit or interfere with the gate post or mounting bracket. Correct as
                       c) Gate is too difficult to move                          necessary.
                                                                              c) Remove arm from gate and move gate manually. Gate must move easily and freely
                                                                                 through its entire range, limit-to-limit. Repair gate as needed.
Operator does not      a)   Check DIAGNOSTIC LEDs                             a)   Use Diagnostic code to identify issue
respond to a wired     b)   Check Open and Close command input LEDs           b)   Check all Open and Close inputs for a “stuck on” input
control/command        c)   Stop button is active                             c)   Check Stop button is not “stuck on”
(example: Open,
Close, SBC, etc.)      d)   Reset button is stuck                             d)   Check Reset button
                       e)   If on battery power only, low or dead batteries   e)   Charges batteries by AC or solar power or replace batteries
                       f)   Entrapment Protection Device active               f)   Check all Entrapment Protection Device inputs for a “stuck on” sensor
                       g)   Vehicle loop detector or vehicle probe active     g)   Check all vehicle detector inputs for a “stuck on” detector
                       h)   Defective control board                           h)   Replace defective control board
Operator does not      a) Check DIAGNOSTIC LEDs                               a) Use Diagnostic code to identify issue
respond to a           b) Check XMITTER LED when wireless control is          b) Activate wireless control and check XMITTER LED is on. Re-learn wireless control/
wireless control or       active                                                 transmitter to control board. Replace wireless control as needed.
transmitter            c) Stop button is active                               c) Check Stop button is not “stuck on”
                       d) Reset button is stuck                               d) Check Reset button
                       e) Poor radio reception                                e) Check if similar wired control operates correctly. Check if wireless controls works properly
                       f) Defective control board                                when within a few feet of operator. Check operator’s antenna and antenna wire. Check
                                                                                 other wireless controls or devices.
                                                                              f) Replace defective control board




                                                                                    38


TROUBLESHOOTING                                                                                                                    TROUBLESHOOTING CHART

FAULT                   POSSIBLE CAUSES                                   CORRECTIONS
Gate stops during       a) Check DIAGNOSTIC LEDs                          a) Use Diagnostic code to identify issue
travel and reverses     b) Inherent force obstruction detection           b) Check for obstruction in gate’s path or travel. Remove arm from gate and move gate
immediately.            c) External Entrapment Protection Device             manually. Gate must move easily and freely through its entire range, limit-to-limit.
                           activation                                        Remove obstruction or repair gate as needed.
                        d) Control (Open, Close) becoming active          c) Check all Entrapment Protection Device inputs for an active sensor
                        e) Vehicle loop detector active                   d) Check all Open and Close inputs for an active input
                        f) Low battery voltage                            e) Check all vehicle detector inputs for an active detector
                                                                          f) Battery voltage must be 22.0 Vdc or higher. Charge batteries by AC or solar power or
                                                                             replace batteries
Gate opens, but will a) Check DIAGNOSTIC LEDs                             a) Use Diagnostic code to identify issue
not close.           b) Open control active                               b) Check all Open inputs for an active input
                     c) Close Entrapment Protection Device active         c) Check all Entrapment Protection Device inputs for an active sensor
                     d) Vehicle loop detector active                      d) Check all vehicle detector inputs for an active detector
                     e) Loss of AC power with AC FAIL set to OPEN         e) Check AC power and AC Fail option setting
                     f) Low battery with LOW BATT set to OPEN             f) Battery voltage must be 22.0 Vdc or higher. Charge batteries by AC or solar power or
                     g) Fire Dept input active                               replace batteries
                                                                          g) Check Fire Dept input
Gate closes, but will a) Check DIAGNOSTIC LEDs                            a)   Use Diagnostic code to identify issue
not open.             b) Open Entrapment Protection Device active         b)   Check all Entrapment Protection Device inputs for an active sensor
                      c) Vehicle loop detector active                     c)   Check all vehicle detector inputs for an active detector
                      d) Low battery with LOW BATT switch set to close    d)   Battery voltage must be 22.0 Vdc or higher
                      e) Low battery with LOW BATT option set to          e)   Check if AC power is available. If no AC power, then running on batteries and battery
                         CLOSE                                                 voltage must be 22.0 Vdc or higher. Charge batteries by AC or solar power or replace
                                                                               batteries
Gate does not close a) Timer-to-Close not set                             a) Check Timer-to-Close (TTC) setting
from Timer-to-Close. b) Open control active                               b) Check all Open inputs for an active input
                     c) Close Entrapment Protection Device active         c) Check all Entrapment Protection Device inputs for an active sensor
                     d) Vehicle loop detector active                      d) Check all vehicle detector inputs for an active detector
                     e) Loss of AC power with AC FAIL set to OPEN         e) Check AC power and AC Fail option setting
                     f) Low battery with LOW BATT option set to OPEN      f) Check if AC power is available. If no AC power, then running on batteries and battery
                     g) Fire Dept input active                               voltage must be 22.0 Vdc or higher. Charge batteries by AC or solar power or replace
                                                                             batteries.
                                                                          g) Check Fire Dept input
Vehicle Exit loop       a)   Check DIAGNOSTIC LEDs                        a)   Use Diagnostic code to identify issue
activation does not     b)   Exit vehicle detector setup incorrectly      b)   Review Exit loop detector settings. Adjust settings as needed.
cause gate to open.     c)   Defective Exit loop detector or loop wire    c)   Check Exit loop wire. Replace defective Exit loop detector.
                        d)   Low battery with LOW BATT option set to      d)   Check if AC power is available. If no AC power, then running on batteries and battery
                             CLOSE                                             voltage must be 22.0 Vdc or higher. Charge batteries by AC or solar power or replace
                                                                               batteries.
Vehicle Interrupt       a) Check DIAGNOSTIC LEDs                          a) Use Diagnostic code to identify issue
loop does not cause     b) Vehicle detector setup incorrectly             b) Review Interrupt loop detector settings. Adjust settings as needed
gate to stop and        c) Defective vehicle loop detector or loop wire   c) Check Interrupt loop wire. Replace defective Interrupt loop detector
reverse.
Vehicle Shadow loop a) Check DIAGNOSTIC LEDs                              a) Use Diagnostic code to identify issue
does not keep gate b) Vehicle detector setup incorrectly                  b) Review Shadow loop detector settings. Adjust settings as needed
at open limit.      c) Defective vehicle loop detector or loop wire       c) Check Shadow loop wire. Replace defective Shadow loop detector




                                                                                39


TROUBLESHOOTING                                                                                                                   TROUBLESHOOTING CHART

FAULT                  POSSIBLE CAUSES                                   CORRECTIONS
Obstruction in gates   a) Force setting too high                         a) Adjust force setting. Retest that obstruction in gate’s path causes gate to stop and reverse
path does not cause                                                         direction.
gate to stop and
reverse
Photoelectric sensor   a) Incorrect photoelectric sensor wiring          a) Check photoelectric sensor wiring. Retest that obstructing photoelectric sensor causes
does not stop or       b) Defective photoelectric sensor                    moving gate to stop, and may reverse direction.
reverse gate.                                                            b) Replace defective photoelectric sensor. Retest that obstructing photoelectric sensor causes
                                                                            moving gate to stop, and may reverse direction.
Edge Sensor does       a) Incorrect edge sensor wiring                   a) Check edge sensor wiring. Retest that activating edge sensor causes moving gate to stop
not stop or reverse    b) Defective edge sensor                             and reverse direction.
gate.                                                                    b) Replace defective edge sensor. Retest that activating edge sensor causes moving gate to
                                                                            stop and reverse direction.
Alarm sounds for 5     a) Double entrapment occurred                     a) Check for cause of entrapment (obstruction) detection and correct. Press the reset button
minutes or alarm                                                            to shut off alarm and reset the operator.
sounds with a
command.
Alarm beeps three      a) Low battery                                    a) Check if AC power is available. If no AC power, then running on batteries and battery
times with a                                                                voltage must be 22.0 Vdc or higher. Charge batteries by AC or solar power or replace
command.                                                                    batteries
On dual-gate           a) Defective or incorrect Operator-to-Operator    a) Check operator-to-operator wiring.
system, one gate is       wiring                                         b) Relearn the wireless network of one operator to the other operator.
not commanding the     b) Incorrect Operator-to-Operator wireless
other.                    learning
On dual-gate           a) Incorrect Bipart switch setting                a) Change setting of both operator’s Bipart switch settings. One operator should have Bipart
system, incorrect                                                           switch ON (operator that opens first) and the other operator should have Bipart switch
gate opens first or                                                         OFF (operator that opens second)
closes first.
Alarm beeps when
running.

Expansion board        a) Defective main board to expansion board        a) Check main board to expansion board wiring. If required, replace wire cable.
function not              wiring                                         b) Check wiring to all inputs on expansion board.
controlling gate.      b) Incorrect input wiring to expansion board      c) Replace defective expansion board or defective main board
                       c) Defective expansion board or defective main
                          board
Maglock not            a) Maglock wired incorrectly                      a) Check that Maglock is wired to N.O. and COM terminals. Check that Maglock has power
working correctly.                                                          (do not power maglock from control board accessory power terminals). If shorting lock’s
                                                                            NO and COM wires does not activate Maglock, then replace Maglock or Maglock wiring

Solenoid lock not      a) Solenoid wired incorrectly                     a) Check that Solenoid is wired to N.C. and COM terminals. Check that Solenoid has power
working correctly.                                                          (do not power solenoid from control board accessory power terminals). If shorting lock’s
                                                                            NC and COM wires does not activate Solenoid, then replace Solenoid lock or Solenoid
                                                                            wiring
Switched (SW)          a) Main control board is not going to low power   a) Photoelectric sensor inputs may be active.
Accessory power           mode.
remaining on.

Accessories            a) Main control board is going to low power       a) With expansion board disconnected and running on batteries (no AC power or solar
connected to Switch       mode.                                             power available), main board will go into low power mode. Move accessory power to
(SW) Accessory                                                              Accy Power ON terminals (+, -). Connect expansion board to prevent low power mode.
power not working
correctly, turning
off, or resetting.

                                                                              40


TROUBLESHOOTING                                                                                                                 TROUBLESHOOTING CHART

FAULT                 POSSIBLE CAUSES                                     CORRECTIONS
Accessories           a) Accessory power protector active                 a) Disconnect all accessory powered devices and measure accessory power voltage (should
connected to          b) Defective control board                             be 23 – 30 Vdc). If voltage is correct, connect accessories one at a time, measuring
Accessory power                                                              accessory voltage after every new connection.
not working                                                               b) Replace defective control board
correctly, turning
off, or resetting.
Quick Close not       a) Quick Close setting incorrect                    a) Check that Quick Close setting is ON
working correctly.    b) Interrupt loop detector or loop wire defective   b) Check operation of Interrupt Loop detector
                      c) Defective Expansion board                        c) Replace defective Expansion board
Anti-Tailgating not   a) Anti-Tail setting incorrect                      a) Check that Anti-Tail setting is ON
working correctly.    b) Interrupt loop detector or loop wire defective   b) Check operation of Interrupt Loop detector
                      c) Defective Expansion board                        c) Replace defective Expansion board
AUX Relay not         a) AUX Relay setting incorrect                      a) Check AUX Relay switches settings
working correctly.    b) AUX Relay wiring incorrect                       b) Check that wiring is connected to either N.O. and COM or to N.C. and COM.
                      c) Defective Expansion board                        c) Set AUX Relay to another setting and test. Replace defective expansion board.




                                                                               41


                                                                                                                                                                                                                                                                                                                                                                                                                     rating.
                                                                                                                                                                                                                                                                                                                                                                                                                     installing or servicing operator.




                                                               NC
                                                                                                                               NC
                                                                                                                                                                                                                                                                                                                                                                                                                  For continued protection against fire:




                                                               COM
                                                                                                                               COM
                                                   LOCK                                                                LOCK
                                                                                                                                                                                                                                                                                                                                                                                                                  To protect against fire and electrocution:




                                                               NO
                                                                                                                              NO
                                                                                                                                                                                                                                                                                                                                                                                                                  • DISCONNECT power and battery BEFORE


                                                                                                                                                                                                                                                                                                                                                                                                                  • Replace ONLY with fuse of same type and

                                                                                                Solenoid Lock
                                                                                                (Optional)                                                         Maglock                          Antenna
                                                                                                                                                                   (Optional)
                                                                                                                                                                                                            SET OPEN            SET CLOSE
                                                               (not provided)                                                  (not provided)                                                                                                                                     XM TTER

                                                                                                                                                                                                                                                                                  NETWORK
                                                                                                                                                                                                                                                   OFF         ON
                                                                                                                                                                                                                                                                                                                               SBC




                                                                                                                                                                                                                                                                                                           OPEN
                                                                                                                                                                                                                                         PRESS &
                                                                                                                                                                                                                                         RELEASE
                                                                                                                                                                                                                                        TO BEG N         (SECONDS
                                                                                                                                                 Red
                                                                                                                                                                                                                                                                                                                                                                                                                                                                             WIRING DIAGRAMS




                                                                                                                                                                                                                                        LMT                10                                                               “F RE
                                                                                                                                                                                                                                        SETUP                                                                               DEPT”




                                                                                                                                                                                                                                                                                                           CLOSE
                                                                                                                                                                                                           MOVE                              1                                                                                OPEN
                                                                                                        12V 7AH Battery                                                                                    GATE
                                                                                                                                                                                                                                             2
                                                                                                                                                                                                                                                   5                 60




                                                                                                                                                                                                                                                                                                           STOP
                                                                                                                                                                                                                                                                                                                              EX T
                                                     Attach to Metal Chassis
                                                                                                                                                                                                                                                   OFF              180 MIN            MAX
                                                                                                                                                                                                                                                                                                                                                                                              Photoelectric Sensors
                                                                                                                                                                                                                               NPUT POWER              T MER                BATT LOW             D AGNOST C
                                                                                                                                                                                                          STATUS:                                                                                  CODES
                                                                                                        12V 7AH Battery                                                                                                        BATT CHARG NG           GATE MOV NG          ACC PWR OVLD                                   SHADOW
                                                                                                                                                                                                                                                                                                                            CLOSE
                                                                                                                                                Black
                                                                                                                                                                                                                                                                                                                             EYES/                                   White




                                                                                                                                                                                                                                                                                                                                     +
                                                                                                                                                                                                                                                                                                                       NTERRUPT                                      White/Black
                                                                                                                                                                                                                                                                                                                                                                                             Edge




                                                                                                                                                                                                                                                                                                                                                                                                                              Photoelectric Sensors
                                                                                                                                       Transformer                                                                                                                                                                                +
                                                                                                                                                                                                                                                                                                                                                                                                                                                          Field Wiring




                                                                                                                                                                                                                                                                                                                                                               White/Black




42
                                                                                                                                                                                                                                                                                                                                                               White
                                                                                                                                                                                                                                                                                                                                                                                                                              Edge




                                                                     Accessory Power
                                                                                                                                                                                                                                                                                                                                J5




                                                                              Outlets
                                                                                                                                                                                                                                                                                                                                     NC
                                                                                                                                                                                                                                                                                                                                     COM




                                                                                                                                                                                To J15
                                                                                                                                                                                                                                           J15                                                                               LOCK
                                                                                                                                                                                                                                                                                                                                     NO




                                                                                                                                                                                                              +          -      -   +
                                                                                                                                                                                                                  BATT          DC
                                                                                                                                                                                                                                                                                                                                    SW




                                                                                                                                                                                                                                POWER
                                                                                                                                                                                                                                                                                                                                  +
                                                                                                                                                                                                                                                                                                                               POWER
                                                                                                                                                                                                                                                                                                                             ACCESSORY
                                                                                                                                                                                                                                                                                                                             ON
                                                                                                                                                                                                                                                                                                                                     +




                                                                                                                                                                                                                                                                                                                                     CLA S 2 SU PLY
                                                                                                                                                                                                                                                                                                                                     24 VO TS
                                                                                                                                                                                                                                                                                                                                                                                    Yellow
                                                                                                                                                                                                                                                                                                                                        EXP




                                                                                                                                                                                                                                                                                                                                                                             Blue
                                                                                                                                                                                                                                                                                                                                       BOARD




                                                               L
                                                                                                                                                                                                                                                                                                                                                                   Black
                                                               GND                                                                                                                                                                                                                                                                                        Red
                                                                                                                                                                                                                                                             SOLAR /
                                                                                                                                                                                                                                                             CHARGER                                                       GROUND
                                                                                                                                                                                             BR GRN WT YE BLU RED            BR GRN WT YE BLU RED               +    -
                                                               N                                     Connect Outlets
                                                                                                                                                                                                                                                                                                 D RESET     ALARM
                                                                                                                                                                                                                                                                                                                                                                            Attach to Outlet Metal Chassis




                                      Input Power Connection
                                                                                                     to Transformer
                                                                                                                                                                                                                                                                                                                                                                            With a Single Screw
                                                                                                     Kit (If Used)                                                                                                                                                                                                                                                                                                           EXPANSION BOARD
                                                                                                                                                             Red                                                                                                                                                                               Loop Detector
 Tranformer Run Kit (Optional)                                                                                                          Black
                                                                                                                                                                                                                                                                                        Purple




                Switch/5A Breaker                                                 Ground
                                                                                                                                     Black                                                                                                                                                                           Red
                                                                                                      Wire Nut                                                      Red
                                                                                                                                                                                         Primary Operator                                                                                                          Black
                                                                                                                                                        +




                                            Red
                                                                    Black
                                                                                                                                                              Bridge Rectifier
                               L                                                                                                                   -     -
                                                                                                                                                                                                                                                                                                                       Piezo Alarm
                                                                                                                                                                                                                                                                                                        Wh te




                                                                                        White               Black
                                                                                                                                                                                                                                                         Red
                                                                                                                                                                                                                                                                                                                                                                                                                                                                            Field Wiring




                                                                                                                                                                                                                                                                    Black




                                                                                                                                                                                                                                                                                                                                                                                                                                                                     N.C.
                                                                                                                                                                                                                                                                                                White




                                                                                                                                                                                                                                                                                                                                                                                                                                         GROUND
                                                                                                                                                                                                         Secondary Operator
                                                                                                                        Gray                                              Yellow
                                                                                                                        Blue                                               White
                                                                                                                                                                                                                                                                                                                   Reset Switch
                           N
                                                                                                                                                                                           Two 12V Solar Panels
                                                                                                                        Brown                                                                                                                                                                                                                                  Wire Loop                Wire Loop




 Input Power Connection
                                                                                                                                                                                           in Series            +                                                           +
                          GND                                                                                                                                              Red                                                                         -                                    -                                                                              Wire Loop                                                              Attach to Outlet
                                                                                                                        Purple
                                   EMI FILTER/SURGE PROTECTION BOARD                                                                                                      Orange                                                                                                                                                                                           Field Wiring                                                           Metal Chassis
                                                                                                                                                                                                                                                                                                                                                                                                                                                  With a Single Screw
                                                                                                                                             Transformer 200 VA
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           STANDARD CONTROL BOX


                                                                                                                                                                                                                                                                                                                                                                                                                  rating.
                                                                                                                                                                                                                                                                                                                                                                                                                  installing or servicing operator.
                                                                                                                                                                                                                                                                                                                                                                                                               For continued protection against fire:




                                                               NC
                                                                                                                               NC
                                                                                                                                                                                                                                                                                                                                                                                                               To protect against fire and electrocution:




                                                                                                                                                                                                                                                                                       Antenna




                                                               COM
                                                                                                                               COM
                                                   LOCK                                                                LOCK
                                                                                                                                                                                                                                                                                                                                                                                                               • DISCONNECT power and battery BEFORE




                                                               NO
                                                                                                                              NO
                                                                                                                                                                                                                                                                                                                                                                                                               • Replace ONLY with fuse of same type and

                                                                                                Solenoid Lock
                                                                                                (Optional)                                                         Maglock                           Coaxial Antenna Cable
                                                                                                                                                                   (Optional)
                                                                                                                                                                                                            SET OPEN            SET CLOSE
                                                               (not provided)                                                  (not provided)                                                                                                                                    XM TTER

                                                                                                                                                                                                                                                                                 NETWORK
                                                                                                                                                                                                                                                  OFF         ON
                                                                                                                                                                                                                                                                                                                              SBC




                                                                                                                                                                                                                                                                                                          OPEN
                                                                                                                                                                                                                                                                                                                                                                                                                                                                          WIRING DIAGRAMS




                                                                                                                                                                                                                                        PRESS &
                                                                                                                                                                                                                                        RELEASE
                                                                                                                                                                                                                                        O BEG N         (SECONDS
                                                                                                                                                 Red
                                                                                                                                                                                                                                        LMT               10                                                               “F RE
                                                                                                                                                                                                                                        SETUP                                                                              DEPT”




                                                                                                                                                                                                                                                                                                          CLOSE
                                                                                                                                                                                                           MOVE                             1                                                                                OPEN
                                                                                                        12V 7AH Battery                                                                                    GATE
                                                                                                                                                                                                                                            2
                                                                                                                                                                                                                                                  5                 60




                                                                                                                                                                                                                                                                                                          STOP
                                                                                                                                                                                                                                                                                                                             EX T
                                                     Attach to Metal Chassis
                                                                                                                                                                                                                                                  OFF              180 MIN            MAX
                                                                                                                                                                                                                                                                                                                                                                                            Photoelectric Sensors
                                                                                                                                                                                                                               NPUT POWER             T MER                BATT LOW             D AGNOST C
                                                                                                                                                                                                          STATUS:                                                                                 CODES
                                                                                                        12V 7AH Battery                                                                                                        BATT CHARG NG          GATE MOV NG          ACC PWR OVLD                                   SHADOW
                                                                                                                                                                                                                                                                                                                           CLOSE
                                                                                                                                                Black
                                                                                                                                                                                                                                                                                                                            EYES/                                   White


                                                                                                                                                                                                                                                                                                                                    +
                                                                                                                                                                                                                                                                                                                      NTERRUPT                                      White/Black
                                                                                                                                                                                                                                                                                                                                                                                           Edge




                                                                                                                                                                                                                                                                                                                                                                                                                           Photoelectric Sensors
                                                                                                                                                                                                                                                                                                                                 +

                                                                                                                                       Transformer
                                                                                                                                                                                                                                                                                                                                                                                                                                                       Field Wiring




43
                                                                                                                                                                                                                                                                                                                                                           White/Black
                                                                                                                                                                                                                                                                                                                                                           White
                                                                                                                                                                                                                                                                                                                                                                                                                            Edge




                                                                     Accessory Power
                                                                                                                                                                                                                                                                                                                               J5




                                                                              Outlets
                                                                                                                                                                                                                                                                                                                                    NC
                                                                                                                                                                                                                                                                                                                                    COM




                                                                                                                                                                                To J15
                                                                                                                                                                                                                                           J15                                                                              LOCK
                                                                                                                                                                                                                                                                                                                                    NO




                                                                                                                                                                                                              +          -      -   +
                                                                                                                                                                                                                  BATT          DC
                                                                                                                                                                                                                                                                                                                                   SW




                                                                                                                                                                                                                                POWER
                                                                                                                                                                                                                                                                                                                                 +
                                                                                                                                                                                                                                                                                                                              POWER
                                                                                                                                                                                                                                                                                                                            ACCESSORY
                                                                                                                                                                                                                                                                                                                            ON
                                                                                                                                                                                                                                                                                                                                    +




                                                                                                                                                                                                                                                                                                                                    CLA S 2 SU PLY
                                                                                                                                                                                                                                                                                                                                    24 VO TS
                                                                                                                                                                                                                                                                                                                                                                                  Yellow
                                                                                                                                                                                                                                                                                                                                       EXP




                                                                                                                                                                                                                                                                                                                                                                           Blue
                                                                                                                                                                                                                                                                                                                                      BOARD




                                                               L
                                                                                                                                                                                                                                                                                                                                                                  Black
                                                               GND                                                                                                                                                                                                                                                                                       Red
                                                                                                                                                                                                                                                            SOLAR /
                                                                                                                                                                                                                                                            CHARGER                                                       GROUND
                                                                                                                                                                                             BR GRN WT YE BLU RED            BR GRN WT YE BLU RED              +    -
                                                               N                                     Connect Outlets
                                                                                                                                                                                                                                                                                                D RESET     ALARM                                                                                                         EXPANSION BOARD




                                      Input Power Connection
                                                                                                     to Transformer
                                                                                                     Kit (If Used)                                                                                                                                                                                                                            Loop Detector
                                                                                                                                                             Red
 Tranformer Run Kit (Optional)                                                                                                          Black
                                                                                                                                                                                                                                                                                       Purple




                Switch/5A Breaker                                                 Ground
                                                                                                                                     Black                                                                                                                                                                          Red
                                                                                                      Wire Nut                                                      Red
                                                                                                                                                                                         Primary Operator                                                                                                         Black
                                                                                                                                                        +




                                            Red
                                                                                                                                                                                                                                                                                                                                                                                                                                                                         Field Wiring




                                                                    Black
                                                                                                                                                              Bridge Rectifier
                               L                                                                                                                   -     -
                                                                                                                                                                                                                                                                                                                      Piezo Alarm                                                                                                                                 N.C.
                                                                                                                                                                                                                                                                                                       White




                                                                                        White               Black
                                                                                                                                                                                                                                                        Red
                                                                                                                                                                                                                                                                   Black
                                                                                                                                                                                                                                                                                               White




                                                                                                                                                                                                         Secondary Operator
                                                                                                                        Gray                                              Yellow
                                                                                                                        Blue                                               White
                                                                                                                                                                                                                                                                                                                  Reset Switch
                                                                                                                                                                                                                                                                                                                                                              Wire Loop               Wire Loop
                           N
                                                                                                                                                                                           Two 12V Solar Panels                                                                                                                                                           Wire Loop
                                                                                                                        Brown




 Input Power Connection
                                                                                                                                                                                           in Series            +                                                          +
                          GND                                                                                                                                              Red                                                                        -                                    -                                                                              Field Wiring
                                                                                                                        Purple
                                   EMI FILTER/SURGE PROTECTION BOARD                                                                                                      Orange

                                                                                                                                             Transformer 200 VA
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        LARGE METAL CONTROL BOX (XLM)


ACCESSORIES
ENTRAPMENT PROTECTION DEVICES                                                                          MISCELLANEOUS

                            PHOTOELECTRIC SENSORS (NON-CONTACT)                                                        PLUG-IN LOOP DETECTOR
                            The photoelectric sensors are designed to detect an obstacle in the                        Low power. Conveniently plugs into existing control board.
                            path of the electronic beam and stop the operator. Includes                                Model LOOPDETLM
                            mounting brackets.
                            Models AOMRON E3K-R10K4-NR (retro-reflective), RETROAB
                            60-2728 (retro-reflective), CPS-UN4 (through beam)                                         LOOP DETECTOR
                                                                                                                       Low power loop detectors mounted and wired separately inside
                            SENSING EDGE (2-WIRE, NON-MONITORED,                                                       control box.
                            CONTACT)                                                                                   Model LD7LP
                            Sensing edges can detect an obstacle upon contact and stop the
                            operator.                                                                                  VEHICLE SENSING PROBE
                            Models G65MG0204, G65MG0205, G65MGR205, and                                                The vehicle sensing probe is buried in the ground and can detect a
                            G65MGS205                                                                                  car as it approaches and will then open the gate.
                            SENSING EDGE CHANNEL                                                                       Model CP3
                            Mounting channel for all MG020 type edges.
                            Model G65ME120C5                                                                           SOLAR PANEL KIT - 10 WATT
REMOTE CONTROLS                                                                                                        This kit is to replace or add a solar panel to the operator
                                                                                                                       application. Up to four solar panels can be connected to the
Chamberlain offers a variety of LiftMaster remote controls to satisfy your application needs.                          operator.
Single-button to 4-button, visor or key chain. The following remote controls are compatible
with operators manufactured by Chamberlain after 1993. Contact your authorized LiftMaster                              Model SOLPNL10W12V (requires 2 minimum)
dealer for additional details and options.
                                                                                                                       BATTERY FOR GATE ACCESS SYSTEMS
                            3-BUTTON REMOTE CONTROL
                                                                                                                       Gate access system batteries replace or upgrade the gate operator
                            The 3-button remote control can be programmed to control the                               batteries.
                            operator. Includes visor clip.
                                                                                                                       Model 29-NP712 (standard 7 AMP-Hour Battery, 12 Vdc, to
                            Model 893MAX                                                                               replace original batteries provided with operator, reuse existing
                                                                                                                       harnesses)
                            3-BUTTON MINI-REMOTE CONTROL                                                               Model A12330SGLPK (upgrade 33 AMP-Hour Battery, 12 Vdc,
                                                                                                                       includes 33AH harness. Ideal for solar applications and extended
                            The 3-button remote control can be programmed to control the
                                                                                                                       battery backup). For use with Large Metal Control Box ONLY.
                            operator. Includes key ring and fastening strip.
                                                                                                                       Two identical 12 Vdc batteries are required for each gate
                            Model 890MAX
                                                                                                                       operator. Do not mix 7AH and 33AH batteries within a gate
                                                                                                                       operator.
                            KEYLESS ENTRY
                            Enables homeowner to operate gate operator from outside by                                 SOLENOID GATE LOCK
                            entering a 4-digit code on a specially designed keypad.
                                                                                                                       The automatic gate lock is a solenoid-driven lock that
                            Model 877MAX                                                                               automatically unlocks when the gate is open and locks when the
                                                                                                                       gate is closed. Can be mounted onto a gate or post. Can be
MISCELLANEOUS
                                                                                                                       released in case of emergency.
                            REMOTE ANTENNA EXTENSION KIT                                                               Models GC824 (115 Vac) and GC824-12 (12/24 Vac/dc)
                            The remote antenna extension kit allows the antenna to be
                            remotely installed.
                                                                                                                       MAGNETIC GATE LOCK
                            Model 86LM
                                                                                                                       Outdoor magnetic lock, transformer, junction box, mounting plate
                                                                                                                       and hardware. Not for use with Solar Applications. Must be
                            WIRELESS ACCESS CONTROL RECEIVER                                                           powered separately.
                            Access control receiver for up to 450 remote controls.                                     Model MG1300
                            Model STAR450-315
                                                                                                                       TRANSFORMER RUN KIT (OPTIONAL
                                                                                                                       Model LA500HDTKITSTD (for Standard Control Box)
                                                                                                                       Model LA500HDTKITXLM (for Large Metal Control Box)




                                                                                                  44


WARRANTY
LIFTMASTER 3 YEAR RESIDENTIAL / 2 YEAR COMMERCIAL LIMITED WARRANTY


The Chamberlain Group, Inc. (“Seller”) warrants to the first purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in
materials and/or workmanship for a period of 3 year residential/ 2 year commercial from the date of purchase [and that the LA500™ and LA500CONT™ are free from
defect in materials and/or workmanship for a period of 3 year residential/ 2 year commercial from the date of purchase]. The proper operation of this product is dependent
on your compliance with the instructions regarding installation, operation, maintenance and testing. Failure to comply strictly with those instructions will void this limited
warranty in its entirety.
If, during the limited warranty period, this product appears to contain a defect covered by this limited warranty, call 1-800-528-2806, toll free, before dismantling this
product. Then send this product, pre-paid and insured, to our service center for warranty repair. You will be advised of shipping instructions when you call. Please include a
brief description of the problem and a dated proof-of-purchase receipt with any product returned for warranty repair. Products returned to Seller for warranty repair, which
upon receipt by Seller are confirmed to be defective and covered by this limited warranty, will be repaired or replaced (at Seller’s sole option) at no cost to you and returned
pre-paid. Defective parts will be repaired or replaced with new or factory-rebuilt parts at Seller’s sole option.
ALL IMPLIED WARRANTIES FOR THE PRODUCT, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE 3 YEAR RESIDENTIAL/
2 YEAR COMMERCIAL LIMITED WARRANTY PERIOD SET FORTH ABOVE [EXCEPT THE IMPLIED WARRANTIES WITH RESPECT
TO THE LA500™ AND LA500CONT™, WHICH ARE LIMITED IN DURATION TO THE 3 YEAR RESIDENTIAL/ 2 YEAR
COMMERCIAL LIMITED WARRANTY PERIOD FOR THE LA500™ AND LA500CONT™], AND NO IMPLIED WARRANTIES WILL
EXIST OR APPLY AFTER SUCH PERIOD. Some states do not allow limitations on how long an implied warranty lasts,
so the above limitation may not apply to you. THIS LIMITED WARRANTY DOES NOT COVER NON-DEFECT DAMAGE,
DAMAGE CAUSED BY IMPROPER INSTALLATION, OPERATION OR CARE (INCLUDING, BUT NOT LIMITED TO ABUSE, MISUSE,
FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTENANCE, UNAUTHORIZED REPAIRS OR ANY ALTERATIONS TO
THIS PRODUCT), LABOR CHARGES FOR REINSTALLING A REPAIRED OR REPLACED UNIT, OR REPLACEMENT OF BATTERIES.
THIS LIMITED WARRANTY DOES NOT COVER ANY PROBLEMS WITH, OR RELATING TO, THE GATE OR GATE HARDWARE,
INCLUDING BUT NOT LIMITED TO THE GATE SPRINGS, GATE ROLLERS, GATE ALIGNMENT OR HINGES. THIS LIMITED
WARRANTY ALSO DOES NOT COVER ANY PROBLEMS CAUSED BY INTERFERENCE. ANY SERVICE CALL THAT DETERMINES
THE PROBLEM HAS BEEN CAUSED BY ANY OF THESE ITEMS COULD RESULT IN A FEE TO YOU.
UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES ARISING
IN CONNECTION WITH USE, OR INABILITY TO USE, THIS PRODUCT. IN NO EVENT SHALL SELLER’S LIABILITY FOR BREACH
OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE OR STRICT LIABILITY EXCEED THE COST OF THE PRODUCT COVERED
HEREBY. NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS
PRODUCT.
Some states do not allow the exclusion or limitation of consequential, incidental or special damages, so the above limitation or exclusion may not apply to you. This limited
warranty gives you specific legal rights, and you may also have other rights which vary from state to state.




                                                                                          45


                       845 Larch Avenue
                  Elmhurst, Illinois 60126-1196


01-36213   © 2011, The Chamberlain Group, Inc. – All Rights Reserved



Document Created: 2012-01-10 13:39:57
Document Modified: 2012-01-10 13:39:57

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC