User Manual Part 1

FCC ID: HBW7545

Users Manual

Download: PDF
FCCID_1627638

      LA500 & LA500-S
VEHICULAR SWING GATE OPERATOR

         INSTALLATION MANUAL




          Your model may look different than the model illustrated in this manual.



   THIS PRODUCT IS TO BE                        This model is for use on vehicular
   INSTALLED AND SERVICED BY                    passage gates ONLY and not
   A TRAINED GATE SYSTEMS                       intended for use on pedestrian
                                                passage gates.
   TECHNICIAN ONLY.
                                                This model is intended for use in
   Visit www.liftmaster.com to                  Class I, II, III and IV vehicular swing
   locate a professional installing             gate applications.
   dealer in your area.




           UL325                                               UL991
           compliant                                           compliant




TABLE OF CONTENTS
SAFETY                                                                                                          1-7          ADJUSTMENT                                                                                                25-26
Safety Symbol and Signal Word Review . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1                         Limit and Force Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25-26
UL325 Model Classifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2                Obstruction Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Safety Installation Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3                 PROGRAMMING                                                                                                       27
Gate Construction Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4                  Remote Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Required Entrapment Protection Devices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5                        Erase All Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-7
                                                                                                                             OPERATION                                                                                                         28
INTRODUCTION                                                                                                    8-9          Manual Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Operator Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8              Reset Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Carton Inventory & Operator Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8                         Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9       Party Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
PREPARATION                                                                                               10-12              MAINTENANCE                                                                                                       29
Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-11              Maintenance Chart. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Mounting Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12              Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
INSTALLATION                                                                                              13-17              ADDITIONAL FEATURES                                                                                       30-35
Manual Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13            Control Board Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Determine the Position of the Post Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13                        Accessory Features on Control Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Determine the Position of the Gate Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . 14                          Expansion Board Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Weld the Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14             Accessory Features on Expansion Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Attach the Operator to the Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15                     Gate Operator Setup Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Standard Control Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16               Limit Setup with a Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Large Metal Control Box (XLM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17                     TROUBLESHOOTING                                                                                           36-41
WIRING                                                                                                    18-24              Control Board LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36-37
Wire the Entrapment Protection Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18                        Troubleshooting Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38-41
Earth Ground Rod . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18              WIRING DIAGRAMS                                                                                           42-43
Wire the Operator Arm to the Control Board. . . . . . . . . . . . . . . . . . . . . . . . . . . 19                           Standard Control Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Dual Gates Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20-21               Large Metal Control Box (XLM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Power Wiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22-23             ACCESSORIES                                                                                                       44
Connect Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23-24
                                                                                                                             WARRANTY                                                                                                          45
Engage the Operator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24




SAFETY                                                                                                                                                       SAFETY SYMBOL AND SIGNAL WORD REVIEW

When you see these Safety Symbols and Signal Words on the following pages, they
will alert you to the possibility of serious injury or death if you do not comply with
the warnings that accompany them. The hazard may come from something
mechanical or from electric shock. Read the warnings carefully.                                                                                                                MECHANICAL
When you see this Signal Word on the following pages, it will alert you to the
possibility of damage to your gate and/or the gate operator if you do not comply
with the cautionary statements that accompany it. Read them carefully.                                                                                                           ELECTRICAL
IMPORTANT NOTE
• BEFORE attempting to install, operate or maintain the operator, you must read
  and fully understand this manual and follow all safety instructions.
• DO NOT attempt repair or service of your gate operator unless you are an
  Authorized Service Technician.
                                                                                                                         1


SAFETY                                                                                                 UL325 MODEL CLASSIFICATIONS


UL325 MODEL CLASSIFICATIONS
CLASS I – RESIDENTIAL VEHICULAR GATE OPERATOR
                                                                                                   I
A vehicular gate operator (or system) intended for use in a home of one-to four
single family dwellings, or a garage or parking area associated therewith.
CLASS II – COMMERCIAL/GENERAL ACCESS VEHICULAR
GATE OPERATOR
A vehicular gate operator (or system) intended for use in a commercial location or                      II
building such as a multi-family housing unit (five or more single family units) hotel,
garage, retail store or other building servicing the general public.
CLASS III – INDUSTRIAL/LIMITED ACCESS VEHICULAR
GATE OPERATOR                                                                                III
A vehicular gate operator (or system) intended for use in a industrial location or
building such as a factory or loading dock area or other location not intended to
service the general public.
CLASS IV– RESTRICTED ACCESS VEHICULAR GATE                                                              IV
OPERATOR
A vehicular gate operator (or system) intended for use in a guarded industrial
location or building such as an airport security area or other restricted access
locations not servicing the general public, in which unauthorized access is prevented
via supervision by security personnel.



UL325 ENTRAPMENT PROTECTION REQUIREMENTS
This chart illustrates the entrapment protection requirements for the UL325 classes.


        GATE OPERATOR ENTRAPMENT PROTECTION
 UL325 Classification                     Swing Gate Operator
                                Primary Type                  Secondary Type
  CLASS I-CLASS IV                    A                           B1 or B2
  In order to complete a proper installation you must satisfy the entrapment
  protection chart shown. That means that the installation must have one primary
  means of entrapment protection and one independent secondary means of
  entrapment protection. Both primary and secondary entrapment protection
  methods must be designed, arranged or configured to protect against
  entrapments in both the open and close directions of gate travel.
  For Example: For a gate system that is installed on a single-family residence
  (UL325 Class I) you must provide the following: As your primary type of
  entrapment protection you must provide
  • Type A - Inherent (built into the operator) entrapment sensing and at
                 least one of the following as your secondary entrapment
                 protection:
  • Type B1 - Non-contact sensors such as photoelectric sensors,
  • Type B2 - Contact sensors such as gate edges



NOTE: UL requires that all installations must have warning signs placed in plain
view on both sides of the gate to warn pedestrians of the dangers of motorized gate
systems.


                                                                                         2


SAFETY                                                                                                                 SAFETY INSTALLATION INFORMATION

SAFETY INSTALLATION INFORMATION
 1. Vehicular gate systems provide convenience and security. Gate systems are            8. Controls intended for user activation must be located at least 6 feet (1.8 m)
    comprised of many component parts. The gate operator is only one                        away from any moving part of the gate and where the user is prevented
    component. Each gate system is specifically designed for an individual                  from reaching over, under, around or through the gate to operate the
    application.                                                                            controls. Outdoor or easily accessible controls shall have a security feature to
 2. Gate operating system designers, installers and users must take into account            prevent unauthorized use.
    the possible hazards associated with each individual application. Improperly
    designed, installed or maintained systems can create risks for the user as
    well as the bystander. Gate systems design and installation must reduce
    public exposure to potential hazards.
 3. A gate operator can create high levels of force in its function as a component
    part of a gate system. Therefore, safety features must be incorporated into
    every design. Specific safety features include:                                      9. The Stop and/or Reset (if provided separately) must be located in the
                                                                                             line-of-sight of the gate. Activation of the reset control shall not cause the
   • Gate Edges                 • Guards for Exposed Rollers                                 operator to start.
   • Photoelectric Sensors      • Screen Mesh
   • Vertical Posts             • Instructional and Precautionary Signage                10. A minimum of two (2) WARNING SIGNS shall be installed, one on each side
                                                                                             of the gate where easily visible.
 4. Install the gate operator only when:
    a. The operator is appropriate for the construction and the usage class of the
        gate.
    b. All openings of a horizontal slide gate are guarded or screened from the
        bottom of the gate to a minimum of 4 feet (1.2 m) above the ground to
        prevent a 2-1/4 inches (6 cm) diameter sphere from passing through the
        openings anywhere in the gate, and in that portion of the adjacent fence
        that the gate covers in the open position.
                                                                                         11. For a gate operator utilizing a non-contact sensor:
                                                                                             a. Reference owner’s manual regarding placement of non-contact sensor for
                                                                                                each type of application.
                                                                                             b. Care shall be exercised to reduce the risk of nuisance tripping, such as
                                                                                                when a vehicle trips the sensor while the gate is still moving.
                                                                                             c. One or more non-contact sensors shall be located where the risk of
                                                                                                entrapment or obstruction exists, such as the perimeter reachable by a
                                                                                                moving gate or barrier.
    c. All exposed pinch points are eliminated or guarded, and guarding is
        supplied for exposed rollers.                                                    12. For a gate operator utilizing a contact sensor such as an edge sensor:
 5. The operator is intended for installation only on gates used for vehicles.               a. One or more contact sensors shall be located where the risk of
    Pedestrians must be supplied with a separate access opening. The pedestrian                 entrapment or obstruction exists, such as at the leading edge, trailing
    access opening shall be designed to promote pedestrian usage. Locate the                    edge and post mounted both inside and outside of a vehicular horizontal
    gate such that persons will not come in contact with the vehicular gate during              slide gate.
    the entire path of travel of the vehicular gate.                                         b. One or more contact sensors shall be located at the bottom edge of a
                                                                                                vehicular vertical lift gate.
                                                                                             c. A hard wired contact sensor shall be located and its wiring arranged so
                                                                                                the communication between the sensor and the gate operator is not
                                                                                                subject to mechanical damage.
                                                                                             d. A wireless contact sensor such as the one that transmits radio frequency
                                                                                                (RF) signals to the gate operator for entrapment protection functions shall
                                                                                                be located where the transmission of the signals are not obstructed or
                                                                                                impeded by building structures, natural landscaping or similar obstruction.
 6. The gate must be installed in a location so that enough clearance is supplied               A wireless contact sensor shall function under the intended end-use
    between the gate and adjacent structures when opening and closing to reduce                 conditions.
    the risk of entrapment. Swinging gates shall not open into public access                 e. One or more contact sensors shall be located on the inside and outside
    areas.                                                                                      leading edge of a swing gate. Additionally, if the bottom edge of a swing
 7. The gate must be properly installed and work freely in both directions prior                gate is greater than 6 inches (152 mm) above the ground at any point in
    to the installation of the gate operator.                                                   its arc of travel, one or more contact sensors shall be located on the
                                                                                                bottom edge.
                                                                                             f. One or more contact sensors shall be located at the bottom edge of a
                                                                                     3          vertical barrier (arm).


SAFETY                                                                                                                              GATE CONSTRUCTION INFORMATION

GATE CONSTRUCTION INFORMATION
Vehicular gates should be installed in accordance with ASTM F2200: Standard Specification for Automated Vehicular Gate Construction. For a copy, contact ASTM directly at
610-832-9585 or www.astm.org.

1.      GENERAL REQUIREMENTS                                                                    3.1.3    A gap, measured in the horizontal plane parallel to the roadway, between a
1.1     Gates shall be constructed in accordance with the provisions given for the                       fixed stationary object nearest the roadway, (such as a gate support post)
        appropriate gate type listed, refer to ASTM F2200 for additional gate types.                     and the gate frame when the gate is in either the fully open position or the
                                                                                                         fully closed position, shall not exceed 2 1/4 inches (57 mm), refer to ASTM
1.2     Gates shall be designed, constructed and installed to not fall over more than                    F2200 for Exception.
        45 degrees from the vertical plane, when a gate is detached from the
        supporting hardware.                                                                    3.1.4    Positive stops shall be required to limit travel to the designed fully open and
                                                                                                         fully closed positions. These stops shall be installed at either the top of the
1.3     Gates shall have smooth bottom edges, with vertical bottom edged                                 gate, or at the bottom of the gate where such stops shall horizontally or
        protrusions not exceeding 0.50 inches (12.7 mm) when other than the                              vertically project no more than is required to perform their intended
        exceptions listed in ASTM F2200.                                                                 function.
1.4     The minimum height for barbed tape shall not be less than 8 feet (2.44 m)               3.1.5    All gates shall be designed with sufficient lateral stability to assure that the
        above grade and for barbed wire shall not be less than 6 feet (1.83 m)                           gate will enter a receiver guide, refer to ASTM F2200 for panel types.
        above grade.
                                                                                                3.2      The following provisions shall apply to Class IV vehicular horizontal slide
1.5     An existing gate latch shall be disabled when a manually operated gate is                        gates:
        retrofitted with a powered gate operator.
                                                                                                3.2.1    All weight bearing exposed rollers 8 feet (2.44 m), or less, above grade
1.6     A gate latch shall not be installed on an automatically operated gate.                           shall be guarded or covered.
1.7     Protrusions shall not be permitted on any gate, refer to ASTM F2200 for                 3.2.2    Positive stops shall be required to limit travel to the designed fully open and
        Exceptions.                                                                                      fully closed positions. These stops shall be installed at either the top of the
1.8     Gates shall be designed, constructed and installed such that their movement                      gate, or at the bottom of the gate where such stops shall horizontally or
        shall not be initiated by gravity when an automatic operator is disconnected.                    vertically project no more than is required to perform their intended
                                                                                                         function.
1.9     A pedestrian gate shall not be incorporated into a vehicular gate panel or
        that portion of the adjacent fence that the gate covers in the open position.


2.      SPECIFIC APPLICATIONS
2.1     Any non-automated gate that is to be automated shall be upgraded to
        conform to the provisions of this specification.
2.2     This specification shall not apply to gates generally used for pedestrian
        access and to vehicular gates not to be automated.                                      4.       VEHICULAR HORIZONTAL SWING GATES
2.3     Any existing automated gate, when the operator requires replacement, shall              4.1      The following provisions shall apply to Class 1, Class II and Class III vehicular
        be upgraded to conform to the provisions of this specification in effect at                      horizontal swing gates:
        that time.
                                                                                                4.1.1    Gates shall be designed, constructed and installed so as not to create an
                                                                                                         entrapment area between the gate and the supporting structure or other
                                                                                                         fixed object when the gate moves toward the fully open position, subject to
3.      VEHICULAR HORIZONTAL SLIDE GATES                                                                 the provisions in the 4.1.1.1 and 4.1.1.2.
3.1     The following provisions shall apply to Class I, Class II and Class III vehicular
                                                                                                4.1.1.1 The width of an object (such as a wall, pillar or column) covered by a swing
        horizontal slide gates:
                                                                                                        gate when in the open position shall not exceed 4 inches (102 mm),
3.1.1   All weight bearing exposed rollers 8 feet (2.44 m), or less, above grade                        measured from the centerline of the pivot point of the gate, refer to ASTM
        shall be guarded or covered.                                                                    F2200 for exception.
3.1.2   All openings located between 48 inches (1.22 m) and 72 inches (1.83 m)                  4.1.1.2 Except for the zone specified in Section 4.1.1.1, the distance between a
        above grade shall be designed, guarded or screened to prevent a 4 inch                          fixed object such as a wall, pillar or column, and a swing gate when in the
        (102 mm) diameter sphere from passing through the openings anywhere in                          open position shall not be less than 16 inches (406 mm), refer to ASTM
        the gate, and in that portion of the adjacent fence that covers in the open                     F2200 for exception.
        position.
                                                                                                4.2      Class IV vehicular horizontal swing gates shall be designed, constructed and
                                                                                                         installed in accordance with security related parameters specific to the
                                                                                                         application in question.

                                                                                            4


SAFETY                                                                                                                REQUIRED ENTRAPMENT PROTECTION DEVICES

REQUIRED ENTRAPMENT PROTECTION DEVICES



  To prevent SERIOUS INJURY or DEATH from a moving gate:
  • Entrapment protection devices MUST be installed to protect anyone who may                 • Locate entrapment protection devices to protect between moving gate and
     come near a moving gate.                                                                   RIGID objects, such as posts or walls.
  • Locate entrapment protection devices to protect in BOTH the open and close
     gate cycles.

An entrapment zone is every location or point of contact where a person can become entrapped between a moving gate and a stationary object. All gate operator systems
REQUIRE two independent entrapment protection systems for each entrapment zone. This operator contains an inherent (internal) entrapment protection system (the primary
entrapment protection system) and REQUIRES the addition of an external entrapment protection system (non-contact photoelectric sensor or contact safety edge sensor) for
EACH entrapment zone.
Your application may contain one or many entrapment zones. Property owners are obligated to test entrapment protection devices monthly.


CONTACT SENSORS (EDGE SENSORS)
If the electrically activated edge sensor comes in contact with an obstruction while the gate is moving, the gate will stop and reverse. The gate will not be able to travel in that
direction until the obstruction is cleared. Use non monitored edge sensor models G65MG0204, G65MGR020, or G65MGS020.

                       3 Edge Contact Sensor

                                                                                         Edge Sensor for Open Cycle                                   Edge Sensor for Close Cycle




NON-CONTACT SENSORS
If the photoelectric sensor beam gets blocked while the gate is moving, the gate will stop and reverse. The gate will not be able to travel in that direction until the obstruction
is cleared. It is best to use monitored photoelectric sensors, model CPS-UN4. If a monitored photoelectric sensor is not working or loses power or the beam is blocked, then ALL
gate operation in that direction will stop. Unmonitored photoelectric sensor models AOMRON and RETROAB are also acceptable.
                                                             Safety Non-Contact Sensor
                                                                                                                                   Sensor for Close Cycle



        Sensor for Open Cycle




                                                                                          5


SAFETY                                                                                                                        IMPORTANT SAFETY INFORMATION

IMPORTANT SAFETY INFORMATION
INSTALLATION




To prevent SERIOUS INJURY or DEATH from a moving gate:
• Pinch points must be guarded at all times. Install enclosed-style gate tracks and       • Entrapment protection devices MUST be installed to protect anyone who may
   roller guards.                                                                           come near a moving gate.
• Place screen mesh 4 feet (1.2 m) high on the gate to prevent access through             • Locate entrapment protection devices to protect in BOTH the open and close
   openings anywhere the gate may travel.                                                   gate cycles.
• Mount controls at least 6 feet (1.8 m) from the gate or ANY moving part of the          • Locate entrapment protection devices to protect between moving gate and RIGID
   gate.                                                                                    objects, such as posts or walls.
• Install Warning signs on EACH side of gate in PLAIN VIEW. Permanently secure            • Too much force on gate will interfere with proper operation of safety reversal
   each Warning sign in a suitable manner using fastening holes.                            system.
• This operator is intended for vehicular use only. To prevent INJURY to                  • NEVER increase force beyond minimum amount required to move gate.
   pedestrians, a separate pedestrian access should be supplied, visible from the         • NEVER use force adjustments to compensate for a binding or sticking gate.
   gate. Locate the pedestrian access where there is not a chance of INJURY at any
                                                                                          • If one control (force or travel limits) is adjusted, the other control may also
   point during full movement of the gate.
                                                                                            need adjustment.
• Contact sensors MUST be located at the leading and trailing edges, and post
                                                                                          • After ANY adjustments are made, the safety reversal system MUST be tested.
   mounted both inside and outside a horizontal swing gate. Non-contact sensors
                                                                                            Gate MUST reverse on contact with a rigid object.
   such as photo eyes MUST be mounted across the gate opening and operate
   during BOTH the open and close cycles.                                                 • DO NOT touch the heater when switch is on, heater may be hot.




• To AVOID damaging gas, power or other underground utility lines, contact                • ALWAYS wear protective gloves and eye protection when changing the battery
  underground utility locating companies BEFORE digging more than 18 inches                 or working around the battery compartment.
  (46 cm) deep.


WIRING




To reduce the risk of SEVERE INJURY or DEATH:
• ANY maintenance to the operator or in the area near the operator MUST NOT               • ALL electrical connections MUST be made by a qualified individual.
   be performed until disconnecting the electrical power (AC or solar and battery)        • DO NOT install ANY wiring or attempt to run the operator without consulting the
   and locking-out the power via the operator power switch. Upon completion of              wiring diagram. We recommend that you install an edge sensor BEFORE
   maintenance the area MUST be cleared and secured, at that time the unit may              proceeding with the control station installation.
   be returned to service.
                                                                                          • ALL power wiring should be on a dedicated circuit and well protected. The
• Disconnect power at the fuse box BEFORE proceeding. Operator MUST be                      location of the power disconnect should be visible and clearly labeled.
   properly grounded and connected in accordance with national and local
                                                                                          • ALL power and control wiring MUST be run in separate conduit.
   electrical codes. NOTE: The operator should be on a separate fused line of
   adequate capacity.

ADJUSTMENT




To reduce the risk of SEVERE INJURY or DEATH:
• Without a properly installed safety reversal system, persons (particularly small        • NEVER use force adjustments to compensate for a binding or sticking gate.
   children) could be SERIOUSLY INJURED or KILLED by a moving gate.                       • If one control (force or travel limits) is adjusted, the other control may also
• Too much force on gate will interfere with proper operation of safety reversal            need adjustment.
   system.                                                                                • After ANY adjustments are made, the safety reversal system MUST be tested.
• NEVER increase force beyond minimum amount required to move gate.                         Gate MUST reverse on contact with a rigid object.

                                                                                      6


SAFETY                                                                                                                        IMPORTANT SAFETY INFORMATION

IMPORTANT SAFETY INFORMATION
ADDITIONAL FEATURES




 To prevent SERIOUS INJURY or DEATH from a moving gate:
 • Entrapment protection devices MUST be installed to protect anyone who may              • Locate entrapment protection devices to protect between moving gate and RIGID
    come near a moving gate.                                                                objects, such as posts or walls.
 • Locate entrapment protection devices to protect in BOTH the open and close
    gate cycles.

MAINTENANCE AND OPERATION




 To reduce the risk of SEVERE INJURY or DEATH:
 • READ AND FOLLOW ALL INSTRUCTIONS.                                                      • Test the gate operator monthly. The gate MUST reverse on contact with a rigid
                                                                                            object or reverse when an object activates the non-contact sensors. After
 • ANY maintenance to the operator or in the area near the operator MUST NOT
                                                                                            adjusting the force or the limit of travel, retest the gate operator. Failure to
    be performed until disconnecting the electrical power (AC or solar and battery)
                                                                                            adjust and retest the gate operator properly can increase the risk of INJURY or
    and locking-out the power via the operator power switch. Upon completion of
                                                                                            DEATH.
    maintenance the area MUST be cleared and secured, at that time the unit may
    be returned to service.                                                               • Use the manual disconnect release ONLY when the gate is not moving.
 • Disconnect power at the fuse box BEFORE proceeding. Operator MUST be                   • KEEP GATES PROPERLY MAINTAINED. Read the owner’s manual. Have a
    properly grounded and connected in accordance with national and local                   qualified service person make repairs to gate hardware.
    electrical codes. NOTE: The operator should be on a separate fused line of            • ALL maintenance MUST be performed by a LiftMaster professional.
    adequate capacity.                                                                    • Activate gate ONLY when it can be seen clearly, is properly adjusted and there
 • NEVER let children operate or play with gate controls. Keep the remote control           are no obstructions to gate travel.
    away from children.                                                                   • To reduce the risk of FIRE or INJURY to persons use ONLY LiftMaster part
 • ALWAYS keep people and objects away from the gate. NO ONE SHOULD CROSS                   29-NP712 for replacement batteries.
    THE PATH OF THE MOVING GATE.                                                          • SAVE THESE INSTRUCTIONS.




 • ALWAYS wear protective gloves and eye protection when changing the battery
   or working around the battery compartment.

TROUBLESHOOTING




 To protect against fire and electrocution:                                               For continued protection against fire:
 • DISCONNECT power (AC or solar and battery) BEFORE installing or servicing              • Replace ONLY with fuse of same type and rating.
    operator.




                                                                                      7


INTRODUCTION                                                      OPERATOR SPECIFICATIONS + CARTON INVENTORY & OPERATOR DIMENSIONS

OPERATOR SPECIFICATIONS
This model is intended for use in vehicular swing gate applications:

   Gate Classifications: CLASS I, II, III, & IV                                           Full Cycle Time: 32 seconds (90 degree opening)
   Main AC Supply: 120 Vac or 240 Vac                                                     Maximum Travel Range: 115 degrees
   Solar Power Max: 24 Vdc at 50 watts max.                                               Maximum Gate Weight/Length:
   Input Rating: 8 Amps at 120 Vac or 1 Amp at 240 Vac                                    • 1600 lbs./8 foot
   Input Rating Excluding Accessory Outlets: 2 Amps at 120 Vac or 1                       • 800 lbs./16 foot
   Amp at 240 Vac
                                                                                          • 600 lbs./18 foot
   *Input Rating of Accessory Outlets: 6 Amps at 120 Vac
                                                                                          Ambient Temperature: -40°C to 60°C (-40°F to 140°F)
   *NOTE: The accessory outlets are not connected for the 240 Vac rating.
                                                                                          Fuse Protection Battery: 30 Amp
   Main Supply (Motor): 24 Vdc
                                                                                          Fuse Protection DC Power: 30 Amp
   Accessory Power: 24 Vdc nominal Class II battery voltage source is
                                                                                          Daily cycle rate for direct plug-in transformer power:
   limited to:
                                                                                          300 cycles/day
   • Accessory wire up to 50 feet - 500 mA
                                                                                          Daily Cycle Rate for toroid transformer (accessory) power:
   • Accessory wire 50 feet up to 250 feet - 250 mA                                       300 cycles/day semi-continuous duty
   • Accessory wire 250 feet up to 1000 feet - 100 mA
   NOTE: Increased accessory power drawn from the operator will shorten the
   battery life (solar applications ONLY).




CARTON INVENTORY & OPERATOR DIMENSIONS
NOT SHOWN: Documentation Packet, Hardware Bag

                                4.21" (10.7 cm)

5.83" (14.8 cm)


                                                                                   Post Bracket            Gate Bracket
                                                                                                                                Warning Signs (2) and Warranty Card
Operator
Model LA500 (1)
Model LA500-S (2)
                          40.35" (102.5 cm)


                                                                                                                                   OR

           Key (2)
                                                                                                       Standard Control Box with
                                                                                                       Batteries 12 Vdc 7AH (2)

                                                    MODEL LA500-S ONLY                                                                   Large Metal Control Box (XLM),
                                                                                                                                         ordered separately (batteries
                                                                                                                                         not included)

               Terminal Block
                 Connector                                                                Watertight Connector (2)
                                                                 Extension Cable
                                       Junction Box

                                                                                      8


INTRODUCTION                                                                                                                                               FEATURES

FEATURES
OPERATOR FEATURES

• Advanced “Centerpiece” Control Board                                                 • Manual - Secure power failure selection
• EMI AC Power Surge Protection and Filter Board                                       • SAMS compatible
  - Main AC voltage input selection: 120 Vac (factory setting) or 240 Vac (field       • Slow-start and slow-stop gate motion
      change)                                                                          • Reset Button
• DC motor with extended brush life                                                    • Audible Alarm
• AC powered with integrated EverCharge® Power Management System                       • Standard Control box has integrated internal antenna with external antenna
• 24 Vdc accessory power                                                                 option. Large Metal Control Box (XLM) has external antenna.
• Programmable with up to 50 remote controls and 2 keyless entries. Compatible         • Electronic limit adjustment and control from the remote control
  with MyQ™ devices and Security✚ 2.0™ codes at either 310, 315, 390 MHz, or           • Wireless primary/secondary (refer to pages 20 and 21)
  433 MHz


CONTROL BOARD FEATURES

•   Electronic Limit adjustment and control                                            • COMMANDS:
•   Adjustable reversal force                                                            - OPEN, CLOSE, or STOP: accessory connection and on-board button
•   Adjustable Timer-to-Close (TTC)                                                      - Single Button Close (SBC): accessory connection
•   Maximum Run Timer                                                                    - FIRE DEPARTMENT OPEN: accessory connection
•   Bipart Delay switch (dual gate applications)                                         - INTEGRATED RADIO RECEIVER:
•   Feedback and Diagnostic LEDs                                                       • LOOPS:
•   Integrated Radio Receiver, Single Button Control (SBC) and 3-Button Station          - EXIT, SHADOW, or INTERRUPT LOOP: accessory connection
    control, three radio frequencies supporting Security✚ 2.0™

EXPANSION BOARD FEATURES

• Plug-in Loop Detector Connectors (Model LOOPDETLM Loop Detector)                     • AUX Relays (2) each independently selectable operation:
  - SHADOW                                                                               - OPEN LIMIT: ON at open limit switch
  - INTERRUPT                                                                            - CLOSE LIMIT: OFF at close limit switch
  - EXIT, with Fail Open/Fail Close selection                                            - GATE MOVING: ON with gate moving
• Quick-Close ON/OFF selection switch                                                    - PRE-ALERT DELAY: ON 3 seconds before gate motion
• AC Fail Open/Battery selection switch                                                  - TAMPER: ON when gate manually pulled from close limit
• Low Battery Open/Close selection switch                                                - POWER: ON with AC or Solar power available
• Anti-Tail ON/OFF selection switch                                                      - CYCLE QUANTITY: LEDs blink operational cycle count
• Single Button Control (SBC) accessory connection
• 3-Button station accessory connection




                                                                                   9


PREPARATION
SITE PREPARATION
Check the national and local building codes BEFORE installation.
                                                                                                                              SAFETY

                                                                                         Entrapment protection devices are required to protect against any entrapment
                                                                                         or safety conditions encountered in your gate application (refer to page 5 for
                                                                                         more details). Install warning signs on both sides of the gate.




                                                                                                                               !     !


                                                                                                                                                   Warning Signs


                                                                                                          Entrapment Danger




                               VEHICLE LOOPS                                                                        EARTH GROUND ROD

  The vehicle loops allow the gate to stay open when vehicles are obstructing the
  gate path. Suggested for vehicles 14 feet (4.27 m) or longer. Vehicle loops are        Proper grounding gives an electrical
  not required but are recommended.                                                      charge, such as from an electrical
                                                                                         static discharge or a near lightning
                                                                                         strike, a path from which to dissipate
                                                                                         its energy safely into the earth.
                                                                                         Without this path, the intense energy
                                                                                         generated by lightning could be                                Check national and local
                                                                                         directed towards the gate operator.                            codes for proper depth
                                                                                         Although nothing can absorb the
                                                                                         tremendous power of a direct lightning
                                                                                         strike, proper grounding can protect
                                                                                         the gate operator in most cases.
                                                    (Inside Property)




                                   GATE                                                                                       CONDUIT

  Gate must be constructed and installed according to ASTM F2200 standards               Conduit must be UL approved for low and high voltage.
  (refer to page 4). Gate must fit specifications of operator (refer to
  specifications).




                                                                                                          Conduit




                                                                                    10


                                                                                                                                                                                                          SITE PREPARATION


                                                                                          INSTALLATION TYPES

Identify your installation type. The installation steps in this manual will show a typical Pull-to-Open application.


                                              PULL-TO-OPEN                                                                                                            PUSH-TO-OPEN

                                                                                                                                               Column Install                                             Post Install
                        Column Install                                     Post Install

                                                                                                                                                                                                                          Gate Hinge
                                                                                                                                                                            Gate Hinge
                                                  Gate Hinge                              Gate Hinge




                                                       Heavy Steel Plate
                                                       for Reinforcement
                                                       (Not provided)
                                                                                                                                                                                  Heavy Steel Plate
                                                                                                                                                                                  for Reinforcement
                                                                                                                                                                                  (Not provided)

                                                         Heavy Steel
                                                         Bracket
                                                         (Reinforce if                    Back Steel Plates                                                                    Back Steel Bracket
                                                         necessary)                       for Reinforcement                                                                    (Reinforce if necessary)
                                                                                          (Not provided)
 10"
 Minimum                                           Back Steel
                                                   Bracket
                                                   (Reinforce if
                                                   necessary)
                                                                                                                                                                                                                          Gate Hinge
                                                                                           Gate Hinge                                                                       Gate Hinge
                                                  Gate Hinge




                                                                                                                     NOTE: Weld Re Bar
  NOTE: Weld Re Bar
                                                                                                                     Behind Gate Hinges for
  Behind Gate Hinges for
                                                                                                                     Maximum Strength.
  Maximum Strength.

                                                                                                                                                            Top View
                                  Top View



                                                                                                                      Heavy Steel Plate for
                                                                                                                      Reinforcement (Not provided)




                                              SINGLE GATE                                                                                                                DUAL GATE
                                 Operator                                                                                       Primary Operator                                              Secondary Operator
         Control Box                                                                                          Control Box                                                                                                Junction Box




                                                   !                                                                                                 !                                    !




  Water Tight Conduit                                                                                                                                    Water Tight Conduit (Not provided)                    Shielded low
  (Not provided)                                                                                                                                                                                               voltage wires.
                           Earth Ground Rod
                                                                                                                            Earth Ground Rod




                                                                                                               11


PREPARATION                                                                                                                                       MOUNTING OPTIONS


MOUNTING OPTIONS
MOUNTING DOs




                                               !                                                                                     !



    Weld a horizontal bar across entire gate on any installation for strength.                     The operator can be mounted on top of the gate frame.
    Make sure that the operator is mounted level or it will not function properly.

MOUNTING DON'Ts




                                                                                                                                              !



    An off-level installation may cause the gate or operator to fail prematurely.                      DO NOT weld the crossbar on just a few pickets, or they could bend.




                                                                                                                             !
                                           !




                       DO NOT install upside down.                                                       DO NOT install on uphill or downhill gates.




 DO NOT install on ANY pedestrian passageways, doorways, or gates.              DO NOT install next to sprinklers
                                                                                or any area that may expose              DO NOT over-bend the cord from the operator.
                                                                                the bottom of operator to water.         Doing this will cause the wires to eventually break.
                                                                                     12


INSTALLATION                                                                  MANUAL RELEASE + DETERMINE THE POSITION OF THE POST BRACKET

MANUAL RELEASE
1    Insert the key into the lock and turn it 180 degrees counterclockwise.


2    Turn the release lever 180 degrees counterclockwise. The operator is now in
     manual mode.




If this operator is a replacement for a Miracle-One™ operator, use the existing post bracket and gate bracket. Remove the Miracle-One™ operator
from the brackets and proceed to page 15.


DETERMINE THE POSITION OF THE POST BRACKET

1    Close the gate.


2
                                                                                                                              7.75"
     Choose a vertical mounting location for the post bracket.


3    Place a measuring tape under the center of the gate hinge point and measure
     out 7.75 inches.


4    Use a screwdriver or dowel rod to temporarily mark the location of the first
     measurement.


5    Measure 8.5 inches from the previous mark.
                                                                                                                   8.5"


6    Use a screwdriver to mark the location of the second measurement.


7    Align the post bracket as close as possible above the screwdriver or dowel rod
     and tack weld the post bracket in the desired vertical position.                                                      7.75"

                                                                                                                    8.5"

                                                                                           Post Bracket Location



                                                                                                                                   PUSH-TO-OPEN
If your application is Push-to-Open, refer to the illustration to the right.



                                                                                                                           7.75"




                                                                                                                           8.5"



                                                                                      13


INSTALLATION                                                          DETERMINE THE POSITION OF THE GATE BRACKET + WELD THE BRACKETS

DETERMINE THE POSITION OF THE GATE BRACKET
The gate bracket MUST be installed in an area that can withstand heavy forces.
Additional reinforcement steel plates may be necessary for mounting.

1     Position a level on the post bracket and measure 27.75 inches over from the
      gate hinge point and mark the location on the gate.


2    Measure 2.25 inches down from the previous mark and tack weld the gate
     bracket in this position.

                                                             27.75"                                                   Gate Bracket Location
                          Gate Hinge Point




                                                                                             2.25"




WELD THE BRACKETS

1    Position the operator on the brackets and make sure the operator is level and
     positioned correctly on the gate.


2    Remove the operator from the gate.


3    Completely weld around the post bracket and gate bracket.




                                                                                     14


INSTALLATION                                                                                         ATTACH THE OPERATOR TO THE BRACKETS

ATTACH THE OPERATOR TO THE BRACKETS

1   Attach the operator to the post bracket with the bolt, mounting plate, and nut
    as shown.


2   Attach the operator to the gate bracket with the bolt, washer, and nut as shown.
    Tighten the nut until it reaches the bottom of the gate bracket, then turn the
    nut a half turn, making sure not to overtighten.


                 Post Bracket




                                                                                                                     Gate Bracket




For dual gate applications, repeat the previous installation steps to install the second operator.




                                                                                       15


INSTALLATION                                                                                                                             STANDARD CONTROL BOX

For Large Metal Control Box installation, refer to the following page.

STANDARD CONTROL BOX
MOUNT THE CONTROL BOX
                                                                                                                       Expansion Board
The control box MUST be mounted within 5 feet (1.52 m) of the gate operator.
Mount the control box as high as possible for best radio reception. Make sure the
control box is level.

1    Remove the screws and open the control box.


2    Disconnect the connector labeled "Main Board" on the expansion board.
                                                                                                                                                            "Main Board" Connector




3    Remove the expansion board by removing the screws.


4    Select the mounting holes and remove the knockouts using a screwdriver and
     hammer.


5    Secure the control box to mounting surface.
     A. Column: Use the provided screws (4).
     B. Wall: Use the provided screws (4).                                                                                                    POST MOUNT

     C. Post: Use U-bolts and rubber washers (not provided) to ensure a watertight                                                                  6.36"
        seal. Make sure the U-bolts do not protrude more than 3/4 inch from the                                                                   4.38"
        control box because this can short the control board.                                         WALL OR COLUMN MOUNT
                                                                                                                                                   3.88"
                                                                                                                                                    5.88"

6
                                                                                                                                                        4.88"
     Reinstall the expansion board and connect the "Main Board" connector to the                               9.13"
                                                                                                                                                    2.88"
     expansion board.




                                                                                             13.75"
                                                                                                                                                                          12.06"




                                                                                    A                                  B                      C




                                                                                        16


INSTALLATION                                                                                                              LARGE METAL CONTROL BOX (XLM)


LARGE METAL CONTROL BOX (XLM)
MOUNT THE CONTROL BOX (XLM)
The control box MUST be mounted within 5 feet (1.52 m) of the gate operator. Mount the control box as high as possible for best radio reception. Make sure the control box
is level.


1    Open the control box. The control box door may be removed by opening the
     door 90°. Lift the door from the hinges and set aside until the installation is
     complete.


                                                                                                    1

                                                                                                                         90°


POST MOUNT


2    The control box can be mounted to a post with 'U' bolts (refer to chart). The
     knock out will accommodate a 3/8" diameter 'U' bolt. Select center mounting
     holes (top and bottom) and knock out using a screwdriver and hammer.
                                                                                                                 2
3    Secure the control box to mounting surface with U-bolts and rubber washers
     (not provided) to ensure a watertight seal.

      TYPE AND SIZE                               'U' BOLT OPENING
                                                                                                                  3
      Standard 3" Round Pipe                      3-1/2"
      Standard 4" Square Post                     4"
      Standard 6" Square Post                     6"




WALL OR COLUMN MOUNT

2    Remove the electrical outlet cover by loosening the screws and sliding the
     cover up.
                                                                                                             3
3    Use knock outs located at the 4 corners of the control box and knock out using
     a screwdriver and hammer.


4    Secure the control box to mounting surface using the provided screws (4).


                                                                                                                  4
                                                                                                                                    2

                                                                                       17


WIRING                                                                           WIRE THE ENTRAPMENT PROTECTION DEVICES + EARTH GROUND ROD

WIRE THE ENTRAPMENT PROTECTION DEVICES
Entrapment protection devices are required. Refer to page 5 for more information regarding application.




  To prevent SERIOUS INJURY or DEATH from a moving gate:
  • Entrapment protection devices MUST be installed to protect anyone who may                      • Locate entrapment protection devices to protect between moving gate and
     come near a moving gate.                                                                        RIGID objects, such as posts or walls.
  • Locate entrapment protection devices to protect in BOTH the open and close
     gate cycles.




1     Connect the entrapment protection device to the EYES EDGE terminal on the
      control board. These inputs are for pulsed photoelectric sensors and dry contact
                                                                                                                                                                                                   SHADOW
                                                                                                                                                                                                    CLOSE
                                                                                                                                                                                                     EYES/




                                                                                                                                                                                                                         -
      edges.
                                                                                                                                                                               INTERRUPT




                                                                                                                                                                                                                         +
      • Close Photoelectric Sensor Entrapment Protection: Connect wires from the
         photoelectric sensors to the Inputs on the CLOSE EYES/INTERRUPT terminal.
      • Close Edge Entrapment Protection: Connect wires from the entrapment
         protection device to the Inputs on the CLOSE EDGE terminal.




                                                                                                                                                                                                                       +
      • Open Entrapment Protection: Connect wires from the entrapment protection




                                                                                                                                                                                                                       -
         device to the Inputs on the OPEN EYES/EDGE terminal.
                                                                                                                               SET     PEN         SET CL SE




                                                                                                                                                                          FF             N



      NOTE: Refer to the “Accessory Features on the Control Board” section on                                                                                RESS &
                                                                                                                                                            REL ASE




                                                                                                                                                                                                                               CL SE
                                                                                                                                                           TO BEG N             E    N S
                                                                                                                                                           LMT                      10                                                      “FIRE
                                                                                                                                                           ETUP                                                                               EPT ”



      page 31.
                                                                                                                              M E                               1                                                                             OPEN
                                                                                                                              GATE
                                                                                                                                                                2
                                                                                                                                                                      5                       60




                                                                                                                                                                                                                               ST P
                                                                                                                                                                                                                                                XIT
                                                                                                                                                                      FF                     180 M N          M X
                                                                                                                                                  INPUT POWER              T MER                    ATT LOW          AGNOSTIC
                                                                                                                             STATUS:                                                                                 CO ES
                                                                                                                                                   ATT CHARGING                ATE MO ING          ACC PWR O L                             SHADOW
                                                                                                                                                                                                                                            CLOSE
                                                                                                                                                                                                                                             EYES/




                                                                                                                                                                                                                                                     -
TO ERASE LEARNED MONITORED PHOTOELECTRIC                                                                                                                                                                                                 NTERRUPT




                                                                                                                                                                                                                                                     +
SENSORS




                                                                                                                                                                                                                                                   +
                                                                                                                                                                                                                                                   -
1    Remove the photoelectric sensor wires from the terminal block.


                                                                                                                                                                                                                                                J5
                                                                                                                                                                                                                                                     N C.
                                                                                                                                                              J15                                                                            LOCK




                                                                                                                                                                                                                                                     N.O.
2
                                                                                                                                 +          -      -   +




                                                                                                                                                                                                                                                    SW.
                                                                                                                                                                                                                                                      -
                                                                                                                                                                                                                                             ACCESSORY
     Press the SET OPEN and SET CLOSE buttons simultaneously until the SET OPEN
                                                                                                                                     BATT          DC
                                                                                                                                                   POWER




                                                                                                                                                                                                                                               POWER
                                                                                                                                                                                                                                               -  +
                                                                                                                                                                                                                                             ON
     and SET CLOSE LEDs turn on.                                                                                                                                                                                                                     +
                                                                                                                                                                                                                                                      LA S 2 U P Y
                                                                                                                                                                                                                                                      4V L S




                                                                                                                                                                                                                                                         EXP.
                                                                                                                                                                                                                                                        BOAR




3
                                                                                                                                                                                    SOLAR /
                                                                                                                                                                                    CHARGER                                                 GROUND
                                                                                                                BR GRN WT YE BLU RED                                                     +



     Press both SET OPEN and SET CLOSE buttons again to turn off the SET OPEN
                                                                                                                                                BR GRN WT YE BLU RED


                                                                                                                                                                                                                    ID RESET     ALARM




     and SET CLOSE LEDs.
NOTE: For dual gate applications repeat the steps above on the other operator.


                                                                                                                                        To Control Box


EARTH GROUND ROD
Use the proper earth ground rod for your local area. The ground wire must be a
single, whole piece of wire. Never splice two wires for the ground wire. If you should
cut the ground wire too short, break it, or destroy its integrity, replace it with a single
wire length.
1     Install the earth ground rod within 3 feet of the control box.
                                                                                                                                                                                                                                       Check national and local

2
                                                                                                                                                                                                                                       codes for proper depth
     Run wire from the earth ground rod to the control box.


NOTE: If the operator is not grounded properly the range of the remote controls will
be reduced.



                                                                                              18



Document Created: 2012-01-10 13:39:20
Document Modified: 2012-01-10 13:39:20

© 2025 FCC.report