                                                   CONTROL BOARD OVERVIEW

                                                                LEARN BUTTON
The LEARN button is used for programming (refer to Programming).




                                                           DIAGNOSTIC DISPLAY
The diagnostic display will show the operator type, firmware version, and codes. The operator type will display as “SL” followed by a “30”
which indicates the operator type as SL3000U. The firmware version will show after the operator type, example “1.2”. For more information
about the codes refer to the Troubleshooting section.




                                                             HANDING BUTTONS

The handing buttons are used to determine which direction the gate will open and they are also used to set the limits                 OPEN
                                                                                                                                      LEFT
                                                                                                                                                         OPEN
                                                                                                                                                         RIGHT
(refer to the Adjustment section).
                                                                                                                                             HANDING
OPEN RIGHT        If the operator is installed on the right side of the drive when looking out of the property, a swing gate
                  will swing to the right (turn counter clockwise) when opening and a slide gate will slide to the right when
                  opening.
OPEN LEFT         If the operator is mounted on the left side of the drive when looking out of the property, a swing gate will swing to the left (turn
                  clockwise) when opening and a slide gate will slide to the left when opening.
NOTE: For gates installed on the outside of the property, the setting will be opposite. Determine the direction by looking towards the property from the
outside.



                                                                 BIPART DELAY

Used in dual gate applications where a maglock, solenoid lock, or decorative overlay would require one gate to close before the other.                 BIPART
                                                                                                                                                       DELAY
The BIPART DELAY is also used in applications where one gate travels a longer distance than the other.                                                   4

ON     The operator with the BIPART DELAY dial ON will delay from the close limit when opening and be the first to close from                      2             6
       the open limit.
                                                                                                                                                                 8
OFF    No affect.



                                                         TIMER-TO-CLOSE (TTC)


The TTC is factory set to OFF (0). Rotate the TIMER-TO-CLOSE dial to the desired setting (0 to 180 seconds). Any radio command, single
button control, or CLOSE command on the control board prior to the TTC expiring will close the gate. The TTC is reset by any signals from
the open controls, loops, close edges, and close photoelectric sensors.
0 seconds (OFF)            The gate will remain open until the operator receives another command from a control.

1-180 seconds (ON)         The gate will automatically close after the specified time period.




                                                                              23


                                                  CONTROL BOARD OVERVIEW

                                                                  FORCE DIAL

The force setting should be high enough that the gate will not reverse by itself nor cause nuisance
interruptions, but low enough to prevent serious injury to a person. The force setting is the same for both the                  5   6
open and close gate directions.                                                                                              4           7
Settings 1-3: Fixed force settings (the force will not adjust due to gate wear or temperature changes)
                                                                                                                     3                            8
Settings 4-10: Automatically increase the force due to gate wear or temperature changes
ADJUST THE FORCE                                                                                                    2                             9

1. Open and close the gate with the TEST BUTTONS, ensuring that the gate is stopping at the proper open and              1                   10
   close limit positions. If the gate is not stopping at the proper limits, adjust the force dial accordingly.
2. Place a solid object between the open gate and a rigid structure. Ensure that the gate, the solid object, and
   the rigid structure can withstand the forces generated during this obstruction test.
3. Run the gate in the close direction. The gate should stop and reverse upon contact with the solid object. If
   the gate does not reverse off the solid object, reduce the force setting by turning the force control slightly
   counter-clockwise. The gate should have enough force to reach both the open and close limits, but MUST
   reverse after contact with a solid object.
4. Repeat the test for the open direction.




                                                                TEST BUTTONS
Used to operate the gate (OPEN, STOP and CLOSE). Also used to view the code history (refer to the Troubleshooting section).




                                                                 STATUS LEDS
 LED                       STATE                    DEFINITION
 INPUT POWER               OFF                      OFF state
                           ON                       AC power available
 TIMER                     OFF                      The timer is disabled
                           ON                       The timer is enabled
                           1 blink/second           The timer is running
                           2 blinks/second          The timer is paused
                           8 blinks/second          The timer is cancelled
 GATE MOVING               OFF                      The gate is stopped
                           ON                       The gate is opening or closing
                           1 blink/second           E1 (single entrapment)
                           8 blinks/second          E2 (double entrapment)
 ACC PWR OVLD              OFF                      OFF state
                           ON                       Accessory overload protector opened




                                                                             24


                                   WIRE ACCESSORIES TO CONTROL BOARD

                                           THREE BUTTON CONTROL STATION
TERMINALS               FUNCTION                                                             WIRING EXAMPLE
OPEN and COMM           Opens a closed gate. Hard open (maintained switch overrides
                        external safeties and resets alarm condition). If maintained,
                        pauses Timer-to-Close at OPEN limit. Opens a closing gate and
                        holds open an open gate (within line-of-sight).                                             +
                                                                                                                    +
CLOSE and COMM          Closes an open gate. Hard close (maintained switch overrides
                        external safeties and resets alarm condition within line-of-sight)                          +
                                                                                                                    –   N.C.
STOP and COMM           Stops a moving gate. Hard stop (maintained switch overrides
                        Open and Close commands and resets alarm condition). If
                        maintained, cancels Timer-to-Close at OPEN limit. Overrides
                        Open and Close commands (within line-of-sight).



                                                          FIRE DEPARTMENT
TERMINALS              FUNCTION                                                              WIRING EXAMPLE
FIRE DEPT (-) and      FIRE DEPT and OPEN terminals act as a hard open. Maintained
OPEN (+)               input overrides (ignores) external safeties (photoelectric sensor
                                                                                                                –
                       and edge), pauses Timer-to-Close momentary input logic as
                       single button control and safeties remain active, re-enables                             +
                       Timer-to-Close.




                                                                     LOOPS
The Loop terminals are used for connecting loops and various control devices such as telephone entry keypads, vehicle probes, etc. Connect the
accessory to the terminals based on how the accessory should function.
TERMINALS               FUNCTION                                                             WIRING EXAMPLE
EXIT and COM            This input is a soft open command (maintained switch does not
                        override external safeties and does not reset alarm condition).
                                                                                                                        –
                        Used for exit probe, telephone entry, external exit loop detector,
                                                                                                                        +
                        or any device that would command the gate to open.
                                                                                                                        –
                        • Opens a closing gate and holds open an open gate, if                                          +
                            maintained, pauses Timer-to-Close at OPEN limit.
                                                                                                                        –
SHADOW and COM          This input is used for external shadow loop detector when loop                                  +
                        is positioned under the swing of the gate.
                        • Holds open gate at open limit
                        • Only active when the gate is at the OPEN limit, disregarded at
                            all other times
                        • Pauses Timer-to-Close at OPEN limit
INTERRUPT and COM       This input is used for photoelectric sensors and external
                        interrupt loop detector when loop is on the outside of the gate.
                        • Holds open gate at open limit
                        • Stops and reverses a closing gate to open limit
                        • Pauses Timer-to-Close at OPEN limit, activates quick close
                            and anti-tailgate features when enabled on the expansion
                            board




                                                                          25


                                   WIRE ACCESSORIES TO CONTROL BOARD

                              PHOTOELECTRIC SENSORS AND EDGE SENSORS
The EYES/EDGE terminals are used for connecting entrapment protection devices. At least one external monitored entrapment protection device is
required prior to gate movement. Monitored entrapment protection devices should have been installed with the operator at the time of installation.
Only ONE monitored device may be connected to each input. A monitored device sends a pulsed signal to the operator so the operator is aware of
the device. If the operator does not receive the signal from the device indicating it is working properly, it will not run in that direction.
TERMINALS          FUNCTION                                                     WIRING EXAMPLE
CLOSE EYES/        The CLOSE EYES/INTERRUPT input is for close
INTERRUPT          direction photoelectric sensors. When an obstruction
                   is sensed during gate closing the gate will open to the
                   full open position. This input will be disregarded                                          –

                   during gate opening and resets the Timer-to-Close.                                          +

                                                                                                               –
CLOSE EDGE         The CLOSE EDGE input is for the close direction edge                                        +
                   sensors. When an obstruction is sensed during gate
                                                                                                               –
                   closing the gate will reverse to the full open position,                                    +
                   disengaging the Timer-to-Close. This input will be
                   disregarded during gate opening.
OPEN EYES/         The OPEN EYES/EDGE input is for open direction




                                                                                           A
                                                                                   M
                                                                                       K
EDGE               photoelectric sensors or edge sensors. When an
                   obstruction is sensed during gate opening the gate will
                   reverse for 4 seconds then stop. This input will be
                   disregarded during gate closing.




                                                                     LOCKS
                                                              MAGLOCK WIRING
TERMINALS              FUNCTION                                                 WIRING EXAMPLE
NC and COM             Normally Closed (N.C.) output for maglocks. Relay
                       activates prior to motor activation and during
                                                                                               CO
                                                                                                    L
                                                                                                          B




                       motor run. Relay is off when motor is off.
                                                                                                PLY

                                                                                                          AX




                                                                                                                                       -
                                                                                                                                           +


                                                         SOLENOID LOCK WIRING
NO and COM             Normally Open (N.O.) output for solenoid locks.
                       Relay activates prior to motor activation and
                       during motor run. Relay is off when motor is off.
                                                                                               CO
                                                                                                    L
                                                                                                          B
                                                                                                    PLY

                                                                                                          AX




                                                                                                                                   -
                                                                                                                                       +




                                                                           26


                                                      EXPANSION BOARD OVERVIEW



 To AVOID damaging the circuit board, relays or accessories, DO NOT connect more than 42 Vdc (32 Vac) to the AUX relay contact terminal blocks.



                 PLUG-IN LOOP DETECTOR INPUTS
           For Plug-In Loop Detectors (Model LOOPDETLM)




                                                                                                                 POWER




                                                                                                                     TO MAIN
                                                                                                                     BOARD
                                                                                                                               MAIN CONTROL BOARD CONNECTION
                                                                                                                               Connected at the factory.

                                                                                                                    EYE
                                                                                                             1     ONLY            EYES/EDGE TERMINALS
                                                                                                                    EYE/
                                                                                                             2     EDGE            Page 29
                                                                                                             3      EYE/
                                                                                                                   EDGE




                                                                                                      OPEN
                                                                                                     CLOSE
                                                                                                                   COM


                                                                                                                   SBC
                                                                                                                   OPN             CONTROL STATION TERMINALS
                                                                                                                   CLS             Page 29
                                                                                                                   STP
                                                                                                                   COM



              SHADOW INTERUPT   EXIT




                                       QUICK
                 LOOP INPUTS                                        ANTI TAIL
                                       CLOSE
                 Page 30                                            SWITCH
                                       SWITCH                                                           RELAY 2 WITH CORRESPONDING SWITCHES
                                                                    See below.
                                       See below.                                                       Page 28
                                                       EXIT FAIL SWITCH
                                                       See below.
                                                                                RELAY 1 WITH CORRESPONDING SWITCHES
                                          AC FAIL SWITCH                        Page 28
                                          Not used.



                                                                    EXIT FAIL SWITCH
OPEN       If the EXIT plug-in loop detector (model LOOPDETLM) detects a fault, then the gate will open and remain open until fault is cleared.
CLOSE      If the EXIT plug-in loop detector (model LOOPDETLM) detects a fault, faults are ignored (EXIT loop is faulted and inoperative).

                                                                      AC FAIL SWITCH
NOT USED

                                                                    ANTI TAIL SWITCH
OFF        When CLOSE EYES/Interrupt loop is activated it causes a closing gate to stop and reverse.
ON         When CLOSE EYES/Interrupt loop is activated it causes a closing gate to pause. Once the vehicle is clear the gate will continue to close.

                                                              QUICK CLOSE SWITCH
OFF        No change to the gate’s normal operation.
ON         When CLOSE EYES/Interrupt loop is deactivated it causes an opening or a stopped gate to close (ignores the Timer-to-Close).


                                                                                          27


                                                                                                                         EXPANSION BOARD OVERVIEW

                                                                                                                                              AUXILIARY RELAY 1 AND 2
Normally Open (N.O.) and Normally Closed (N.C.) relay contacts to control external devices, for connection of Class 2, low voltage (42 Vdc [34 Vac] max 5
Amps) power sources only. Function of relay contact activation determined by switch settings.

 RELAY SETTING                        SWITCH SETTINGS                                                                                                AUX RELAY 1                                               AUX RELAY 2
                                       1                         2                      3
    Off (no feature                   OFF                      OFF                      OFF                       Relay always off.
       selected)
  Open Limit Switch                   OFF                      OFF                      ON                        Energizes at open limit. Use with SAMS (Sequenced Access Management System, jointly with barrier
                                                                                                                  gate).
  Close Limit Switch                  OFF                       ON                      OFF                       Energizes when not at close limit. For an additional audible or visual display, connect an external light
                                                                                                                  (low voltage).
     Gate Motion                      OFF                       ON                      ON                        Energizes when motor is on (gate in motion). For an additional audible or visual display, connect an
                                                                                                                  external buzzer or light (low voltage).
   Pre-Motion Delay                   ON                       OFF                      OFF                       Energizes 3 seconds before gate motion and remains                       Energizes 3 seconds before gate motion and
                                                                                                                  energized during gate motion. The onboard alarm will                     remains energized during gate motion. For an
                                                                                                                  sound. For an additional audible or visual display,                      additional audible or visual display, connect an
                                                                                                                  connect an external buzzer or light (low voltage).                       external buzzer or light (low voltage).
        Power                         ON                        ON                      OFF                                                                                     Not used.
       Tamper                         ON                       OFF                      ON                        Energizes if gate is manually tampered with by being pushed off of close limit. For an additional audible
                                                                                                                  or visual display, connect an external buzzer or light (low voltage).
    Cycle Quantity                    ON                        ON                      ON                        The 1, 2, and 3 LEDs will blink out the cycle count                      Not used.
     Feedback*                                                                                                    (cycle count is stored on the control board). See
                                                                                                                  below.

CYCLE COUNT
                                                                                                                                                                                RED/GREEN LIGHT FUNCTIONALITY
* First, note the current Aux Relay switch positions. To determine                                                                                               Red light wired to AUX RELAY 1. Green light wired to AUX RELAY 2.
  the actual cycles that the gate operator has run (in thousands),
  set all three Aux Relay switches to the ON setting for Aux Relay                                                                                                                 AUX RELAY 1 SWITCHES                AUX RELAY 2 SWITCHES
                                                                                                                                                                 GATE STATE
  1. The Expansion Board’s 1, 2, and 3 LEDs will blink out the                                                                                                                     1 OFF       2 OFF       3 OFF     1 ON          2 ON    3 ON
  cycle count, with 1 LED blinking 1000’s, 2 LED blinking
  10,000’s, 3 LED blinking 100,000’s, and simultaneously all                                                                                                       Closed              Red light OFF*                       Green light OFF
  three LED’s blink 1,000,000’s (e.g. 1 LED blinks 3 times, 2 LED                                                                                                  Opening           Red light ON/Flash                     Green light OFF
  blinks 6 times, and 3 LED blinks once. Cycle count is 163,000.).
  Cycle count displayed is between 1,000 and 9,999,000 cycles.                                                                                                      Open               Red light OFF                        Green light ON
  After servicing, set Aux Relay switches back to their appropriate                                                                                                Closing           Red light ON/Flash                     Green light OFF
  positions. Cycle count cannot be reset or changed. If under
  1,000 cycles the 1, 2, and 3 LEDs will turn on for 10 seconds,                                                                                            Defined Mid Stop                   n/a                                   n/a
  then turn off.                                                                                                                                             Undefined Mid
  NOTE: The expansion board will flash the cycle count 3 times                                                                                                                             Red light ON                     Green light OFF
                                                                                                                                                                 Stop
  then all the LEDs will turn on solid for 10 seconds then turn off.
                                                                                                                                                            Timer more than 5
                                                                                                                                                                                       Red light OFF                        Green light ON
                                                                                                                                                                seconds
       AUXILIARY RELAY WIRING EXAMPLE
                                                                                                                                                            Timer less than 5
                                                                                                                                                                                     Red light ON/Flash                     Green light OFF
                                                                                                                                                                seconds
                                                                                                                                       OPEN
                                                                                                                                      CLOSE




                                                                                                                                               COM


                                                                                                                                               SBC
                                                                                                                                               OPN
                                                                                                                                               CLS
                                                                                                                                                           * For red light ON when gate is closed, set switch 1 on AUX RELAY 1 to ON
                                                                                                                                               STP
                                                                                                                                               COM



             SHADOW INTERUPT   EXIT
                                            AUX Relay 1 N.O.


                                                                     AUX Relay 1 N.C.

                                                                                         AUX Relay 2 N.O.


                                                                                                                   AUX Relay 2 N.C.
                                                               Com




                                                                                                            Com




                                                                                                                                                                                                                   Traffic Light



                                                                                                                                                                                                                   Class 2 Power Source
                                                                                                                                                                                                                   (42 Vdc [34 Vac], 5 A maximum)
                                                                                                                                                                                                       –
                                       AUX RELAY 1                                       AUX RELAY 2
                                                                                                                                                            28                                             +


                                 WIRE ACCESSORIES TO EXPANSION BOARD

                               PHOTOELECTRIC SENSORS AND EDGE SENSORS
The EYES/EDGE terminals are used for connecting entrapment protection devices. At least one external monitored entrapment protection device is
required prior to gate movement. Monitored entrapment protection devices should have been installed with the operator at the time of installation.
Only ONE monitored device may be connected to each input. A monitored device sends a pulsed signal to the operator so the operator is aware of
the device. If the operator does not receive the signal from the device indicating it is working properly, it will not run in that direction.
TERMINALS              FUNCTIONALITY                                                               WIRING EXAMPLE
EYE ONLY and COM       Open or Close Direction Photoelectric Sensors, the functionality is based




                                                                                                                                         T
                       on the switch settings (located next to the terminals)                                                1
                                                                                                                                       EYE
                                                                                                                                      ONLY
                                                                                                                                       EYE/
                       Switch set to CLOSE: gate reverses fully when an obstruction is sensed                                2        EDGE
                                                                                                                                       EYE/
                                                                                                                             3
                                                                                                                                      EDGE
                       Switch set to OPEN: gate reverses 4 seconds when an obstruction is




                                                                                                                      OPEN
                                                                                                                     CLOSE
                                                                                                                                      COM

                       sensed
                                                                                                                                      SBC


EYE/EDGE and COM       Open or Close Direction Photoelectric Sensors or Edge Sensor, the
                       functionality is based on the switch settings (located next to the                             1
                                                                                                                                  EYE
                                                                                                                                 ONLY

                       terminals)                                                                                     2
                                                                                                                                  EYE/
                                                                                                                                 EDGE
                                                                                                                      3           EYE/

                       Switch set to CLOSE: gate reverses fully when an obstruction is sensed                                    EDGE




                                                                                                               OPEN
                                                                                                              CLOSE
                                                                                                                             COM

                       Switch set to OPEN: gate reverses 4 seconds when an obstruction is
                       sensed                                                                                                    SBC



EYE/EDGE and COM       Open or Close Direction Photoelectric Sensors or Edge Sensor, the




                                                                                                                                  T
                       functionality is based on the switch settings (located next to the                             1
                                                                                                                              EYE
                                                                                                                             ONLY

                       terminals)                                                                                     2
                                                                                                                              EYE/
                                                                                                                             EDGE
                                                                                                                      3       EYE/
                       Switch set to CLOSE: gate reverses fully when an obstruction is sensed                                EDGE




                                                                                                              OPEN
                                                                                                             CLOSE
                                                                                                                             COM
                       Switch set to OPEN: gate reverses 4 seconds when an obstruction is
                       sensed                                                                                                SBC




                                                          CONTROL STATION
TERMINALS              FUNCTIONALITY                                                               WIRING EXAMPLE
SBC and COM            •   Gate command sequence - Open, Stop, Close, Stop, ...
                       •   Soft Open ,Soft Close, Soft Stop (maintained switch does not
                                                                                                     CLOSE




                                                                                                                      COM
                           override external safeties and does not reset alarm condition)
                                                                                                      O




OPEN and COM           •   Open command - opens a closed gate                                                         SBC
                                                                                                                      OPN
                       •   Soft open (maintained switch does not override external safeties and
                           does not reset alarm condition)                                                            CLS
                                                                                                                      STP
                       •   If maintained, pauses Timer-to-Close at OPEN limit
                                                                                                                     COM
                       •   Opens a closing gate and holds open an open gate
CLOSE and COM          •   Close command - closes an open gate
                       •   Soft close (maintained switch does not override external safeties and
                           does not reset alarm condition)
STOP and COM           •   Stop command - stops a moving gate
                       •   Hard stop (maintained switch overrides Open and Close commands
                           and resets alarm condition)
                       •   If maintained, pauses Timer-to-Close at OPEN limit
                       •   Overrides an Open or Close command




                                                                          29


                               WIRE ACCESSORIES TO EXPANSION BOARD

                                                                                                                                              LOOPS
INPUTS      FUNCTIONALITY                                                                                                                                                                                WIRING EXAMPLE
EXIT        Loop wire connection for plug-in loop detector when loop is inside secured area
            near gate.
            • Open command - opens a closed gate
            • Soft open (maintained switch does not override external safeties and does
               not reset alarm condition)
            • If maintained, pauses Timer-to-Close at OPEN limit
                                                                                                                                                                                                                               SHADOW INTERUPT                 EXIT
            • Opens a closing gate and holds open an open gate




                                                                                                                                                                                                                                Shadow Loop


                                                                                                                                                                                                                                              Interrupt Loop
SHADOW      Loop wire connection for plug-in loop detector when loop is positioned under




                                                                                                                                                                                                                                                               Exit Loop
            the gate.
            • Holds open gate at open limit
            • Disregarded during gate motion
            • Pauses Timer-to-Close at Open Limit
INTERRUPT   Loop wire connection for plug-in loop detector when loop is on the outside of
            the gate.
            • Holds open gate at open limit
            • Stops and reverses a closing gate
            • Pauses Timer-to-Close at Open Limit




                                                                       ADDITIONAL WIRING

SAMS WIRING WITH RELAYS NOT ENERGIZED

                                                                Control Board
                                                                                                                                                                                                       Barrier Arm Operator
                                                                                          BIPART
                                                                                          DELAY
                                                                                             4
                                                                                                                                                                                        Exit Input
                                                                                   2                 6


                                                  OPEN
                                                  LEFT
                                                                      OPEN
                                                                      RIGHT
                                                                                                     8
                                                                                                                                                                                                         C
                                                          HANDING
                                                                                                                                                                                                              Auxiliary
                                                                                                                                                                                                              Command

                                                                                                                                                                                                         NO
                                                                                                                                                                                  A
                                                                                                                                                                    COMM
                                                                                                                                                                           LINK
                                                                                                                                                                                  B
                                                                                                                                                                       CLASS 2 SUPPLY

                                                                                                                                                                         500 mA MAX
                                                                                                                                      GND




                                                                                                                                                                           24 VAC




                                                      ANTENNA       CURRENT MOTOR DRIVE                     RPM & LIMITS ALARM EXP.         24 VAC IN
                                                                     SENSOR                      ID RESET                     BOARD




                                                                                                                                                                                                                              Access Device

                                                                                             Expansion Board                                                                            Shadow Input
                                                                                                                                                                 POWER
                                                                                                                                                                             TO MAIN
                                                                                                                                                                             BOARD




                                                                                                                                                                DEVICE INPUTS
                                                                                                                                                                        EYE
                                                                                                                                                                1      ONLY
                                                                                                                                                                        EYE/
                                                                                                                                                                2      EDGE
                                                                                                                                                                3       EYE/
                                                                                                                                                                       EDGE
                                                                                                                                                         OPEN
                                                                                                                                                        CLOSE




                                                                                                                                                                       COM


                                                                                                                                                                       SBC
                                                                                                                                                                       OPN
                                                                                                                                                                           CLS
                                                                                                                                                                           STP
                                                                                                                                                                      COM



                                                                        SHADOW INTERUPT   EXIT




                        Dipswitch settings for AUX
                        Relay 1: 1-OFF, 2-OFF, 3-ON
                                                                                                                                                          AUX Relay 1




                                                                                                                                                                      30


                                                                                                                   ADDITIONAL WIRING




 To protect against fire and electrocution:                                                                                                                 For continued protection against fire:
 • DISCONNECT power BEFORE installing or servicing operator.                                                                                                • Replace ONLY with fuse of same type and rating.



FIELD WIRING
                                                                                                            CONTROL BOARD
                                             BIPART
                                             DELAY
                                                  4
                                                                                                                                                       +
                                                           6
                                                                                                                                                       +                3-BUTTON
                                         2
                                                                                                                                                       +                CONTROL
 OPEN                         OPEN                         8                                                                                           –         N.C.   STATION
 LEFT                         RIGHT                                                                                                                    –
                                                                                                                                                       +                FIRE DEPARTMENT
            HANDING
                                                                                                                                                       –                                             INTERRUPT LOOP or
                                                                                                                                                       +                EXIT LOOP                    PHOTOELECTRIC SENSORS for CLOSE cycle
                                                                                                                                                       –
                                                                                                                                                       +                SHADOW LOOP
                                                                                                                                                       –
                                                                                                                                                       +
                                                                                                                                                       –                                                EDGE SENSOR for CLOSE cycle
                                                                                                                                                       +
                                                                                                                                                       –
                                                                                                                                                       +                                                                     EDGE SENSOR or
                                                                                                                                                                                                                             PHOTOELECTRIC SENSORS
                                                                                                                                                                                                                             for OPEN cycle
                                                                                                                                                                              Shielded Twisted Pair Cable (Primary/Secondary
                                                                                                                                                 A




                                                                                                                                                                              link to other gate operator) Ground the shield of the
                                                                                                                                   COMM
                                                                                                                                          LINK
                                                                                                                                                 B




                                                                                                                                                       N.C.                   cable to the chassis ground of each operator.
                                                                                                                                                       COM                                                                               Maglock
                                                                                                                                                       N.O.                                                                              (Optional)
                                                                                                                                                                                      Solenoid Lock
                                                                                                                                                        –
                                                                                                                                      CLASS 2 SUPPLY




                                                                                                                                                              ACCESSORY                 (Optional)
                                                                                                                                        500 mA MAX
                                                                                                      GND




                                                                                                                                          24 VAC




                                                                                                                                                        +     POWER
     ANTENNA                CURRENT MOTOR DRIVE                   RPM & LIMITS ALARM EXP.                   24 VAC IN
                             SENSOR                    ID RESET                     BOARD                                                                     24 Vac 500 mA
                                                                                                                                                              Maximum                                  OR
                                                                                                                                                                                                                              (Not Provided)



PLUG-IN LOOP DETECTOR
   Model LOOPDETLM                                                                                                                                                                  (Not Provided)

                                                                                                                        NOTE: These switches determine if the
                                                                                                                        corresponding photoelectric sensor or edge                                          HEATER
                                      EXPANSION BOARD                                                                   sensor will function for the OPEN or CLOSE cycle.

                                                                                       POWER
                                                                                            TO MAIN
                                                                                            BOARD




                                                                                            EYE                     +
                                                                                       1

                                                                                       2
                                                                                           ONLY
                                                                                            EYE/                    +            PHOTOELECTRIC SENSORS
                                                                                       3
                                                                                           EDGE
                                                                                            EYE/
                                                                                           EDGE
                                                                                                                    +               PHOTOELECTRIC SENSORS or
                                                                                                                    –               EDGE SENSORS
                                                                                OPEN
                                                                               CLOSE




                                                                                           COM
                                                                                                                                                                                    JUNCTION BOX
                                                                                           SBC                      +            SINGLE BUTTON
                                                                                           OPN                      +            CONTROL STATION
                                                                                           CLS                      +
                                                                                           STP                      +            3-BUTTON
                                                                                           COM                      – N.C.       CONTROL STATION
   SHADOW INTERUPT   EXIT
                                                            COM


                                                                       COM
                                                            N.O.
                                                            N.C.
                                                                       N.O.
                                                                       N.C.




                                                                      NOTE: These switches control how
                                                                      the Auxiliary Relays will function.
                                                      AUXILIARY AUXILIARY
                                                        RELAY 1 RELAY 2

   INTERRUPT
      LOOP


   SHADOW LOOP
                                                                                                                                                                                           L
                                                                                                                                                                                          N
                                                                                                                                                                                        GND




                                                                                                                                                                                      Incoming Power
        EXIT LOOP



                                                                                                                                                       31


                                                                                            PROGRAMMING

                                                                REMOTE CONTROLS (NOT PROVIDED)

A total of 50 Security+ 2.0™ remote controls and 2 keyless entries (1 PIN for each keyless entry) can be programmed to the operator. When
programming a third keyless entry to the operator, the first keyless entry will be erased to allow the third keyless entry to be programmed. When the
operator’s memory is full it will exit the programming mode and the remote control will not be programmed. The memory will need to be erased
before programming any additional remote controls. NOTE: If installing an 86LM to extend the range of the remote controls DO NOT straighten the
antenna.
There are 3 different options for programming the remote control depending on how you would like the remote control to function. Choose a
programming option:

 OPTION                                  DESCRIPTION                                                 PROGRAMMING STEPS
 Single button as OPEN                   Program a single button on the                              1. Press and release the LEARN button (operator will beep and green XMITTER
 only                                    remote control for open only. The                              LED will light). NOTE: The operator will time out of programming mode after 30
                                         Timer-to-Close can be set to close                             seconds.
                                         the gate.
                                                                                                     2. Press the OPEN button.
                                                                                                     3. Press the remote control button that you would like to program.
 Single button (SBC) as                  Program one remote control button                           1. Press and release the LEARN button (operator will beep and green XMITTER
 OPEN, CLOSE, and                        as an open, close, and stop.                                   LED will light). NOTE: The operator will time out of programming mode after 30
 STOP                                                                                                   seconds.
                                                                                                     2. Press the remote control button that you would like to program.
 Three separate buttons                  Program each remote control button                          1. Press and release the LEARN button (operator will beep and green XMITTER
 as OPEN, CLOSE, and                     as an open, close, and stop.                                   LED will light). NOTE: The operator will time out of programming mode after 30
 STOP                                                                                                   seconds.
                                                                                                     2. Press the OPEN, CLOSE, or STOP button, depending on the desired function.
                                                                                                     3. Press the remote control button that you would like to program.


The operator will automatically exit learn mode (operator will beep and green XMITTER LED will go out) if programming is successful. To program
additional Security+ 2.0™ remote controls or remote control buttons, repeat the programming steps above.
Once the remote control has been programmed the operator will operate as follows:
When gate is in the closed position, activation of the remote control button will open the gate. During the open cycle another activation of the remote
control will stop the gate and the next activation of the remote control will close the gate. When the gate is in the open position, activation of the
remote control button will close the gate. If the remote control is activated while the gate is closing, the gate will stop and the next activation will open
the gate.



NOTICE: This device complies with part 15 of the FCC rules and Industry Canada (IC) licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This Class B digital apparatus complies with Canadian ICES-003.
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.




                                                                                                                32


                                                              PROGRAMMING

                              LIFTMASTER INTERNET GATEWAY (NOT PROVIDED)

To program the operator to the LiftMaster Internet Gateway:

    Program using the learn button on the operator's control board:                     Program using the reset button on the operator:
 1. Connect the ethernet cable to the LiftMaster Internet Gateway and       1. Connect the ethernet cable to the LiftMaster Internet Gateway and the
    the router.                                                                router.
 2. Connect power to the LiftMaster Internet Gateway.                       2. Connect power to the LiftMaster Internet Gateway.
 3. Create an online account by visiting www.myliftmaster.com.              3. Create an online account by visiting www.myliftmaster.com.
 4. Register the LiftMaster Internet Gateway.                               4. Register the LiftMaster Internet Gateway.
 5. Use an internet enabled computer or smartphone to add devices.          5. Use an internet enabled computer or smartphone to add devices. The
    The LiftMaster Internet Gateway will stay in learn mode for three          LiftMaster Internet Gateway will stay in learn mode for three minutes.
    minutes.
                                                                            6. Ensure gate is closed.
 6. Press the Learn button twice on the primary operator (the operator
                                                                            7. Give the operator an OPEN command.
    will beep as it enters learn mode). The LiftMaster Internet Gateway
    will pair to the operator if it is within range and the operator will   8. Within 30 seconds, when the gate is at the open limit press and
    beep if programming is successful.                                         release the reset button 3 times (on primary gate) to put primary
                                                                               operator into High Band Learn Mode (the operator will beep as it
                                                                               enters learn mode). The LiftMaster Internet Gateway will pair to the
                                                                               operator if it is within range and the operator will beep if programming
                                                                               is successful.

The status as shown by the LiftMaster Internet Gateway app will be either “open” or “closed”. The gate operator can then be controlled through the
LiftMaster Internet Gateway app.




                                                            ERASE ALL CODES

1. Press and release the LEARN button (operator will beep and green XMITTER LED will light).
2. Press and hold the LEARN button again until the green XMITTER LED flashes and then release the button (approximately 6 seconds). All remote
   control codes are now erased.




    TO REMOVE AND ERASE ALL MONITORED ENTRAPMENT PROTECTION DEVICES

1. Remove the entrapment protection device wires from the terminal block.
2. Press and release the OPEN LEFT and OPEN RIGHT buttons simultaneously. The handing direction LED will remain solid. The other direction LED
   will begin flashing (entering setup mode).
3. Press the OPEN LEFT and OPEN RIGHT buttons simultaneously to exit.




                                                                            33


                                                                    SETTINGS

GATE OPERATOR SETUP EXAMPLES

The following are example setups for the gate operator. Your specific site requirements may be different. Always setup the operator system to the site
requirements, including all necessary entrapment protection devices.
   RESIDENTIAL: One to four residential homes sharing a gated entrance/exit, allowing vehicle access trumps security concerns
   COMMERCIAL/GENERAL ACCESS: A residential community (more than four homes) having one or more gated entrances/exits, allowing
   vehicle access trumps security concerns
   COMMERCIAL: Business site where security (gate closed) is important
   INDUSTRIAL: Large business site where security is required



 Setting                    RESIDENTIAL                    COMMERCIAL/                           COMMERCIAL                        INDUSTRIAL
                                                           GENERAL ACCESS
 Quick Close switch         Normally set to OFF.           Normally set to OFF. Normal           Normally set to OFF. Normal       Set to ON, so that gate
 setting                    Normal gate close (timer or    gate close (timer or control).        gate close (timer or control).    closes immediately after
                            control).                                                                                              vehicle passes CLOSE EYES/
                                                                                                                                   Interrupt loop.
 Anti-Tail switch setting   Normally set to OFF. CLOSE     Normally set to OFF. CLOSE            Set to ON. In attempt to          Set to ON. In attempt to
                            EYES/Interrupt loop            EYES/Interrupt loop reverses a        prevent vehicle tail-gating,      prevent vehicle tail-gating,
                            reverses a closing gate.       closing gate.                         CLOSE EYES/Interrupt loop         CLOSE EYES/Interrupt loop
                                                                                                 pauses a closing gate.            pauses a closing gate.
 Bipart Delay switch        For DUAL-GATE site, set to     For DUAL-GATE site, set to ON         For DUAL-GATE site, set to        For DUAL-GATE site, set to
 setting                    ON for gate that delays        for gate that delays upon             ON for gate that delays upon      ON for gate that delays upon
                            upon opening.                  opening.                              opening.                          opening.
 Aux Relay Out – Open       Typically not required.        Use with SAMS (Sequence               1) Use with SAMS (Sequence        1) Use with SAMS (Sequence
 Limit Switch                                              Access Management System).               Access Management                 Access Management
                                                                                                    System).                          System).
                                                                                                 2) Connect “Gate Open”            2) Connect “Gate Open”
                                                                                                    indicator (e.g. light).           indicator (e.g. light).
 Aux Relay Out – Close      Typically not required.        Typically not required.               Connect “Gate Close/Secure”       Connect “Gate Close/Secure”
 Limit Switch                                                                                    indicator (e.g. light).           indicator (e.g. light).
 Aux Relay Out – Gate       Attach alert signal (audible   Attach alert signal (audible or       Attach alert signal (audible or   Attach alert signal (audible or
 Motion                     or visual alert system).       visual alert system).                 visual alert system).             visual alert system).
 Aux Relay Out –            Attach alert signal (audible   Attach alert signal (audible or       Attach alert signal (audible or   Attach alert signal (audible or
 Pre-Motion Delay           or visual alert system).       visual alert system).                 visual alert system).             visual alert system).
 Aux Relay Out – Tamper     Attach alert signal (audible   Attach alert signal (audible or       Attach alert signal (audible or   Attach alert signal (audible or
 (Slide Gates Only)         or visual alert system) to     visual alert system) to indicate if   visual alert system) to           visual alert system) to
                            indicate if gate is manually   gate is manually tampered with        indicate if gate is manually      indicate if gate is manually
                            tampered with by being         by being pushed off of close          tampered with by being            tampered with by being
                            pushed off of close limit.     limit.                                pushed off of close limit.        pushed off of close limit.
 Cycle Quantity Feedback    Use during servicing only to Use during servicing only to            Use during servicing only to      Use during servicing only to
                            determine operator cycles.   determine operator cycles.              determine operator cycles.        determine operator cycles.
 Fire Dept Open input       Typically not required.        Connect emergency access              Typically not required.           Typically not required.
                                                           system (Knox box switch, SOS
                                                           system, etc.).
 Heater Accessory           The heater keeps the           The heater keeps the gearbox          The heater keeps the gearbox      The heater keeps the gearbox
 (Model HTRNB)              gearbox and batteries at a     and batteries at a suitable           and batteries at a suitable       and batteries at a suitable
                            suitable temperature when      temperature when the outside          temperature when the outside      temperature when the
                            the outside temperature is     temperature is below -4°F. The        temperature is below -4°F.        outside temperature is below
                            below -4°F. The thermostat     thermostat MUST be set                The thermostat MUST be set        -4°F. The thermostat MUST
                            MUST be set between 45°F       between 45°F and 60°F to              between 45°F and 60°F to          be set between 45°F and
                            and 60°F to ensure proper      ensure proper gate operation.         ensure proper gate operation.     60°F to ensure proper gate
                            gate operation.                                                                                        operation.




                                                                             34


                                                                  SETTINGS

DUAL GATE SETTINGS

NOTE: We recommend that all accessories and board configurations are set on the primary operator.

MAIN CONTROL BOARD

        FEATURE                             PRIMARY OPERATOR                                           SECONDARY OPERATOR
 Timer-to-Close           Set the TTC dial to desired setting                       OFF

 Bi-Part Delay Switch     Bi-Part Delay: ON (will open last and close first)        Bi-Part Delay: OFF (will open first and close last)
                          Tandem Mode: OFF                                          Tandem Mode: OFF



      ACCESSORY                             PRIMARY OPERATOR                                           SECONDARY OPERATOR
 Remote Controls         Program remote controls 1 to 50 to the primary operator.   Program remote controls 51 to 100 to the secondary operator
 LiftMaster Internet     Program to primary operator.
 Gateway
 Garage and Gate         Program to primary operator.
 Monitor

EXPANSION BOARD

                   FEATURE                                 PRIMARY OPERATOR                                 SECONDARY OPERATOR
            QUICK CLOSE Switch                                       ON                                                OFF
              ANTI-TAIL Switch                                       ON                                                OFF




                                                                           35


                                                              MAINTENANCE

IMPORTANT SAFETY INFORMATION


  To reduce the risk of SEVERE INJURY or DEATH:
  • READ AND FOLLOW ALL INSTRUCTIONS.                                             • Test the gate operator monthly. The gate MUST reverse on contact
                                                                                    with a rigid object or reverse when an object activates the non-
  • ANY maintenance to the operator or in the area near the operator                contact sensors. After adjusting the force or the limit of travel, retest
    MUST NOT be performed until disconnecting the electrical power (AC              the gate operator. Failure to adjust and retest the gate operator
    or solar and battery) and locking-out the power via the operator                properly can increase the risk of INJURY or DEATH.
    power switch. Upon completion of maintenance the area MUST be
    cleared and secured, at that time the unit may be returned to service.        • Use the manual disconnect release ONLY when the gate is NOT
                                                                                    moving.
  • Disconnect power at the fuse box BEFORE proceeding. Operator
    MUST be properly grounded and connected in accordance with                    • KEEP GATES PROPERLY MAINTAINED. Read the owner’s manual.
    national and local electrical codes. NOTE: The operator should be on            Have a qualified service person make repairs to gate hardware.
    a separate fused line of adequate capacity.                                   • ALL maintenance MUST be performed by a LiftMaster professional.
  • NEVER let children operate or play with gate controls. Keep the               • Activate gate ONLY when it can be seen clearly, is properly adjusted
    remote control away from children.                                              and there are no obstructions to gate travel.
  • ALWAYS keep people and objects away from the gate. NO ONE                     • SAVE THESE INSTRUCTIONS.
    SHOULD CROSS THE PATH OF THE MOVING GATE.
  • The entrance is for vehicles ONLY. Pedestrians MUST use separate
    entrance.




  To protect against fire and electrocution:                                        For continued protection against fire:
  • DISCONNECT power (AC or solar and battery) BEFORE installing or               • Replace ONLY with fuse of same type and rating.
    servicing operator.



MAINTENANCE
Disconnect all power to the operator before servicing.

 DESCRIPTION                          TASK                                                                            CHECK AT LEAST ONCE EVERY
                                                                                                                     MONTH                  6 MONTHS
 Entrapment Protection Devices        Check and test for proper operation                                               X
 Warning Signs                        Make sure they are present                                                        X
 Manual Disconnect                    Check and test for proper operation                                                                         X
 Drive Chain and Sprockets            Check for excessive slack and lubricate                                           X
 Belt and Pulley                      Check for excessive slack, wear or damage                                                                   X
 Gate                                 Inspect for wear or damage                                                        X
 Accessories                          Check all for proper operation                                                                              X
 Electrical                           Inspect all wire connections                                                                                X
 Chassis Mounting Bolts               Check for tightness                                                                                         X
 Operator                             Inspect for wear or damage                                                                                  X


NOTES:
• Severe or high cycle usage will require more frequent maintenance checks.
• Limits may have to be reset after any major drive chain adjustments.
• If lubricating chain, use only lithium spray. Never use grease or silicone spray.
• Over time, the drive chain on the operator will stretch and need to be tightened. To tighten the drive chain adjust either of the two chain eye bolts.
  The chain should have no more than 1 inch of sag for every 10 feet of chain length.
• It is suggested that while at the site voltage readings be taken at the operator. Using a digital voltmeter, verify that the incoming voltage to the
  operator is within ten percent of the operator’s rating.


                                                                             36


                                                                        TROUBLESHOOTING



 To protect against fire and electrocution:                                                       For continued protection against fire:
 • DISCONNECT power (AC or solar and battery) BEFORE installing or                                • Replace ONLY with fuse of same type and rating.
   servicing operator.


DIAGNOSTIC CODES

TO VIEW THE CODES                                                                                                                                          OPEN, CLOSE, & STOP BUTTONS
The codes will show on the diagnostic display.                                                             DIAGNOSTICS DISPLAY
                                                              ...then press
                                                              and hold the                                                                            BIPART
                                                                                                                                                      DELAY
                                                              OPEN button
                                                                                                                                                           4
                                                              until "Er"
                            ...then press                     shows on                                                                            2                6


                            and hold the                      the display.                                          OPEN               OPEN                        8
                                                                                                                    LEFT               RIGHT
                            CLOSE button...
Press and                                                                                                                  HANDING

hold the
STOP
button...




The operator will show the code sequence number followed by the code
number:




                                                                                                                                                                                                                                    A
                                                                                                                                                                                                                      COMM
                                                                                                                                                                                                                             LINK
CODE SEQUENCE NUMBER




                                                                                                                                                                                                                                    B
                                                       CODE NUMBER
The first number shown is the most                     The second number shown after the
recent code (example: "01"). The         A SECOND      code sequence number is the code




                                                                                                                                                                                                                         CLASS 2 SUPPLY
                                                                                                                                                                                                                           500 mA MAX
display will show the sequence of




                                                                                                                                                                                                    GND




                                                                                                                                                                                                                             24 VAC
                                         LATER....     itself (31-99, example" "31"). Refer to
codes that occurred starting with "01"                 the chart on the following page for an                          ANTENNA       CURRENT MOTOR DRIVE
                                                                                                                                      SENSOR                   ID RESET
                                                                                                                                                                          RPM & LIMITS ALARM EXP.
                                                                                                                                                                                            BOARD
                                                                                                                                                                                                          24 VAC IN

and going up to code "20".                             explanation of each code.




                                                                                                      TO EXIT
                                                                                                      Press and release the STOP button to exit. The display will also time out
                                                                                                      after two minutes of inactivity.



TO SCROLL THROUGH THE SAVED CODES
                                                                                                      TO RESET THE CODE HISTORY
                                                                                                      1. Press and hold the STOP button for six seconds. The display will
                                                                                                         show "Er" then "CL" alternately for six seconds.
Press the OPEN button                                                                                 2. Release the STOP button. The code history has now been reset and
to cycle to the most
recent code ("01").                                                                                      the display will show "- -" until a new code occurs.
                                              Press the CLOSE button                                  3. Press and release the STOP button to exit.
                                              to cycle to the oldest
                                              code (up to "20").



The operator will only keep track of up to 20 codes, then will start saving
over the oldest codes as new codes occur.




                                                                                                 37


                                                         TROUBLESHOOTING

DIAGNOSTIC CODES continued...
Some codes are saved in the code history and some are not. If a code is not saved it will briefly appear on the display as it occurs, then disappear.


                                                                                               External Entrapment                  Inherent Entrapment
      LiftMaster System              Installed System              Informational
                                                                                               Protection                           Protection


    Code       Meaning                                               Solution                                                                    Saved
               Main control board has experienced an internal       Disconnect all power, wait 15 seconds, then reconnect power (reboot).         NO
      31
               failure.                                             If issue continues, replace main control board.
               Max-Run-Time Exceeded Error                          Attempt to run and review for duration and obstructions. Max-Run-             YES
      35
                                                                    Time can be re-measured by saving one or both of the limits again.
               Product ID Error                                     Was the control board just replaced? If so, erase limits, enter limit         YES
      36                                                            setup mode and set limits. If not, disconnect all power, wait 15
                                                                    seconds, then reconnect power before changing product ID harness.
               Product ID Failure                                   Unplug product ID harness then plug back in. Disconnect all power,            YES
      37                                                            wait 15 seconds, then reconnect power before replacing product ID
                                                                    harness.
               Loop Error - Failure or missing exit loop (SHORT     Check loop wiring throughout connection. May be a short in the loop,          YES
      43
               or OPEN - LiftMaster Plug-in Loop Detector only)     or an open connection in the loop.
               Loop Error - Failure or missing shadow loop          Check loop wiring throughout connection. May be a short in the loop,          YES
      44       (SHORT or OPEN - LiftMaster Plug-in Loop             or an open connection in the loop.
               Detector only)
               Loop Error - Failure or missing interrupt loop       Check loop wiring throughout connection. May be a short in the loop,          YES
      45       (SHORT or OPEN - LiftMaster Plug-in Loop             or an open connection in the loop.
               Detector only)
      46       Wireless edge battery low                            Replace batteries in wireless edge.                                           YES
               Motor control board fault                            Relay fault detected in the motor control board. Replace the motor            YES
      47
                                                                    control board.
               Run-Distance Error                                   The limits are less than the minimum requirement or longer than what          YES
      50                                                            was learned. Check limit positions and proper switch function.
                                                                    Run-distance can be re-learned by setting the handing again.
               Brownout occurred                                    AC/DC board supply dipped below allowable level. Review power                 YES
      53                                                            supply and wiring. If rebooting, ensure enough time for discharge of
                                                                    power to force a fresh boot.
               Wireless Second Operator Communication Error         Check the second operator for power. If OFF, restore power and try to         YES
      54                                                            run the system. If powered, deactivate the wireless feature and then
                                                                    re-learn the second operator.
      55       System AC Overvoltage                                Call utility.                                                                 YES
      56       System AC Undervoltage                               Check wiring and wire gauge to operator.                                      YES
               Limit Error - Stuck Switch                           Check switch for proper operation. Check harness for shorts. Replace          YES
      57
                                                                    if defective.
      58       Limit Error - Wrong Switch                           Check motor wiring.                                                           YES
      59       Missing Power Board                                  Check harness for shorts. Check for presence of power board.                  YES
               Minimum number of monitored entrapment               Review monitored entrapment protection device connections.                    NO
      60
               protection devices (one) not installed.
               CLOSE EYE/INTERRUPT held more than 3 minutes         Check CLOSE EYE/INTERRUPT input on main board; check for                      YES
      61
               (main board)                                         alignment or obstruction.
               CLOSE EDGE held more than 3 minutes (main            Check CLOSE EDGE input on main board; check for alignment or                  YES
      62
               board)                                               obstruction.
               OPEN EYE/EDGE held more than 3 minutes (main         Check OPEN EYE/EDGE input on main board; check for alignment or               YES
      63
               board)                                               obstruction.
               CLOSE EYE/INTERRUPT held more than 3 minutes         Check wired input on expansion board; check for alignment or                  YES
      64
               (expansion board)                                    obstruction.
               CLOSE EYE/EDGE held more than 3 minutes              Check wired input on expansion board; check for alignment or                  YES
      65
               (expansion board)                                    obstruction.


                                                                           38


                                                          TROUBLESHOOTING

DIAGNOSTIC CODES continued...
Some codes are saved in the code history and some are not. If a code is not saved it will briefly appear on the display as it occurs, then disappear.

                                                                                               External Entrapment                  Inherent Entrapment
      LiftMaster System              Installed System               Informational
                                                                                               Protection                           Protection


    Code       Meaning                                               Solution                                                                   Saved
               OPEN EYE/EDGE held more than 3 minutes                Check wired input on expansion board; check for alignment or                 YES
     66
               (expansion board)                                     obstruction.
     67        Wireless edge triggered more than 3 minutes           Check wired input for wiring issue or obstruction.                           YES
     68        Wireless edge loss of monitoring                      Check wireless edge inputs.                                                  YES
               Wireless edge triggered                               IF an obstruction occurred, no action required. If an obstruction did        NO
     69
                                                                     NOT occur, check inputs and wiring.
               CLOSE EYE/INTERRUPT triggered, causing                IF an obstruction occurred, no action required. If an obstruction did        NO
     70        reversal, preventing close, or resetting TTC (main    NOT occur, check alignment, inputs, and wiring.
               board)
               CLOSE EDGE triggered, causing reversal,               IF an obstruction occurred, no action required. If an obstruction did        NO
     71
               preventing close, or canceling TTC (main board)       NOT occur, check alignment, inputs, and wiring.
               OPEN EYE/EDGE triggered, causing reversal or          IF an obstruction occurred, no action required. If an obstruction did        NO
     72
               preventing opening (main board)                       NOT occur, check alignment, inputs, and wiring.
               CLOSE EYE/INTERRUPT triggered, causing                IF an obstruction occurred, no action required. If an obstruction did        NO
     73        reversal, preventing close, or resetting TTC          NOT occur, check alignment, inputs, and wiring.
               (expansion board)
               CLOSE EYE/EDGE triggered, causing reversal and        IF an obstruction occurred, no action required. If an obstruction did        NO
     74        preventing close or canceling TTC (expansion          NOT occur, check alignment, inputs, and wiring.
               board)
               OPEN EYE/EDGE triggered, causing reversal or          IF an obstruction occurred, no action required. If an obstruction did        NO
     75
               preventing opening (expansion board)                  NOT occur, check alignment, inputs, and wiring.
               Close input (EYE/EDGE) communication fault from       Check inputs and communication method between operators, either              YES
     80        other operator                                        wired bus or radio. Ensure operator is powered. May have to erase the
                                                                     wireless communication and reprogram the two operators.
               Open input (EYE/EDGE) communication fault from        Check inputs and communication method between operators, either              YES
     81        other operator                                        wired bus or radio. Ensure operator is powered. May have to erase the
                                                                     wireless communication and reprogram the two operators.
               Close input (EYE/EDGE) communication fault            Check the connections between the main board and the expansion               YES
     82
               (expansion board)                                     board.
               Open input (EYE/EDGE) communication fault             Check the connections between the main board and the expansion               YES
     83
               (expansion board)                                     board.
               Force Reversal                                        Look for obstruction, if no obstruction, check that the mechanical           YES
     91                                                              assembly is engaged and free to move. See section on Limit and Force
                                                                     Adjustment, and Obstruction Test.
               RPM / STALL Reversal                                  Check for obstruction. If no obstruction, check the operator cable           YES
     93                                                              wiring and that the operator arm is engaged and free to move. Replace
                                                                     RPM assembly.
               AC motor no start condition                           Motor start sequence failed. If the gate and motor are NOT moving, or        YES
                                                                     moving too slow, check for an obstructed gate, binding in the
                                                                     mechanism, and relay board and start capacitor connections. If the
     95
                                                                     gate and motor ARE moving, failure is due to loss of the encoder
                                                                     signal. Check the encoder cup and sensor on the limit shaft, and
                                                                     wiring.
     99        Normal Operation                                      No action required                                                           YES




                                                                            39


                                                          TROUBLESHOOTING

OPERATOR ALARM
If a contact sensor detects an obstruction twice consecutively the alarm
will sound (up to 5 minutes) and the operator will need to be reset. If a
command is given after the initial 5 minutes the operator will beep.
When the inherent force of the operator (RPM/current sensor) detects the
following (twice consecutively) the alarm will sound (up to 5 minutes)
and the operator will need to be reset:
A. The gate is hitting a wall or vehicle.
B. The gate does not meet specifications.
                                                                                  A   B
C. Debris is on the gate's track such as mud, rocks, dirt, etc.
D. The gate has one or more broken axles or wheels.
E. The gate wheel is off the gate rail.
Remove any obstructions. Press the reset button to shut off the alarm
and reset the operator. After the operator is reset, normal functions will
resume.

                                                                                  C   D




                                                                                  E




                                                                             40


                                                         TROUBLESHOOTING

TROUBLESHOOTING CHART
SYMPTOM               POSSIBLE CAUSES                                    SOLUTIONS
Operator does not     a) No power to control board                       a) Check AC power
run and               b) Open fuse                                       b) Check fuses
diagnostics display
not on.               c) Defective control board                         c) Replace defective control board
Control board         a) Reset switch is stuck                           a) Check reset switch
powers up, but        b) Stop button active or jumper not in place       b) Check Stop button is not “stuck on”, or verify that the stop button is a
motor does not           for stop circuit                                   normally closed circuit, or put a jumper on the stop circuit.
run.
                      c) Open or Close input active                      c) Check all Open and Close inputs for a “stuck on” input
                      d) Entrapment Protection Device active             d) Check all Entrapment Protection Device inputs for a “stuck on” sensor
                      e) Vehicle loop detector or probe active           e) Check all vehicle detector inputs for a “stuck on” detector
                      f) Defective control board                         f) Replace defective control board
Gate moves, but       a) Gate does not move to a limit position          a) Use manual disconnect, manually move gate, and ensure gate moves easily
cannot set correct    b) Gate is too difficult to move                      limit to limit. Repair gate as needed.
limits.                                                                  b) Gate must move easily and freely through its entire range, limit to limit.
                      c) Limits are set too close (slide gate
                         applications only)                                 Repair gate as needed.
                                                                         c) Ensure the gate moves at least four feet between the OPEN limit and the
                                                                            CLOSE limit.
Gate does not fully   a) Gate does not move to a limit position          a) Use manual disconnect, manually move gate, and ensure gate moves easily
open or fully close   b) Gate is too difficult to move                      limit to limit. Repair gate as needed.
when setting                                                             b) Gate must move easily and freely through its entire range, limit to limit.
limits.                                                                     Repair gate as needed.
Operator does not     a) Check Open and Close command input LEDs         a) Check all Open and Close inputs for a “stuck on” input
respond to a wired    b) Stop button is active                           b) Check Stop button is not “stuck on”
control/command
(example: Open,       c) Reset button is stuck                           c) Check Reset button
Close, SBC, etc.)     d) Entrapment Protection Device active             d) Check all Entrapment Protection Device inputs for a “stuck on” sensor
                      e) Vehicle loop detector or vehicle probe active   e) Check all vehicle detector inputs for a “stuck on” detector
Operator does not     a) Check XMITTER LED when wireless                 a) Activate wireless control and check XMITTER LED is on. Re-learn wireless
respond to a             control is active                                  control/transmitter to control board. Replace wireless control as needed.
wireless control or   b) Stop button is active                           b) Check Stop button is not “stuck on”
transmitter
                      c) Reset button is stuck                           c) Check Reset button
                      d) Poor radio reception                            d) Check if similar wired control operates correctly. Check if wireless controls
                                                                            works properly when within a few feet of operator. Check operator’s
                                                                            antenna and antenna wire. Check other wireless controls or devices.
Gate stops during   a) Control (Open, Close) becoming active             a) Check all Open and Close inputs for an active input
travel and reverses b) Vehicle loop detector active                      b) Check all vehicle detector inputs for an active detector
immediately.

Gate opens, but       a) Open control active                             a) Check all Open inputs for an active input
will not close with   b) Vehicle loop detector active                    b) Check all vehicle detector inputs for an active detector
transmitter or
Timer-to-Close.       c) Fire Dept input active                          c) Check Fire Dept input
                      d) Timer-to-Close not set                          d) Check Timer-to-Close (TTC) setting
                      e) Close Entrapment Protection Device active       e) Check all Entrapment Protection Device inputs for an active sensor
Gate closes, but      a) Vehicle loop detector active                    a) Check all vehicle detector inputs for an active detector
will not open.


Exit loop activation a) Exit vehicle detector setup incorrectly          a) Review Exit loop detector settings. Adjust settings as needed.
does not cause       b) Defective Exit loop detector                     b) Replace defective Exit loop detector.
gate to open.



Interrupt loop does a) Vehicle detector setup incorrectly                a) Review Interrupt loop detector settings. Adjust settings as needed.
not cause gate to   b) Defective vehicle loop detector                   b) Replace defective Interrupt loop detector.
stop and reverse.




                                                                           41


                                                         TROUBLESHOOTING

TROUBLESHOOTING CHART continued...

SYMPTOM               POSSIBLE CAUSES                               SOLUTIONS
Shadow loop does      a) Vehicle detector setup incorrectly         a) Review Shadow loop detector settings. Adjust settings as needed.
not keep gate at      b) Defective vehicle loop detector            b) Replace defective Shadow loop detector.
open limit.
Obstruction in       a) Force adjustment needed                     a) Refer to the Adjustment section to conduct the obstruction test and perform
gate's path does not                                                   the proper force adjustment that is needed.
cause gate to stop
and reverse
Photoelectric         a) Incorrect photoelectric sensor wiring      a) Check photoelectric sensor wiring. Retest that obstructing photoelectric
sensor does not       b) Defective photoelectric sensor                sensor causes moving gate to stop, and may reverse direction.
stop or reverse                                                     b) Replace defective photoelectric sensor. Retest that obstructing photoelectric
gate.                                                                  sensor causes moving gate to stop, and may reverse direction.
Edge Sensor does      a) Incorrect edge sensor wiring               a) Check edge sensor wiring. Retest that activating edge sensor causes moving
not stop or reverse   b) Defective edge sensor                         gate to stop and reverse direction.
gate.                                                               b) Replace defective edge sensor. Retest that activating edge sensor causes
                                                                       moving gate to stop and reverse direction.
Alarm sounds for 5    a) Double entrapment occurred (two            a) Check for cause of entrapment (obstruction) detection and correct. Press the
minutes or alarm         obstructions within a single activation)      reset button to shut off alarm and reset the operator.
sounds with a
command.

On dual-gate          a) Incorrect Bipart switch setting            a) Change setting of both operator’s Bipart switch settings. One operator
system, incorrect                                                      should have Bipart switch ON (operator that opens second) and the other
gate opens first or                                                    operator should have Bipart switch OFF (operator that opens first)
closes first.

Alarm beeps when      a) Expansion board setting                    a) Pre-warning is set to "ON"
running.              b) Constant pressure to open or close is      b) Constant pressure to open or closed is given
                         given

Expansion board       a) Defective main board to expansion          a) Check main board to expansion board wiring. If required, replace wire cable.
function not             board wiring                               b) Check wiring to all inputs on expansion board.
controlling gate.     b) Incorrect input wiring to expansion        c) Replace defective expansion board or defective main board
                         board
                      c) Defective expansion board or defective
                         main board
Maglock not           a) Maglock wired incorrectly                  a) Check that Maglock is wired to N.C. and COM terminals. Check that Maglock
working correctly.                                                     has power (do not power maglock from control board accessory power
                                                                       terminals). If shorting lock’s NO and COM wires does not activate Maglock,
                                                                       then replace Maglock or Maglock wiring (refer to Wiring Diagrams).

Solenoid lock not     a) Solenoid wired incorrectly                 a) Check that Solenoid is wired to N.O. and COM terminals. Check that Solenoid
working correctly.                                                     has power (do not power solenoid from control board accessory power
                                                                       terminals). If shorting lock’s NC and COM wires does not activate Solenoid,
                                                                       then replace Solenoid lock or Solenoid wiring (refer to Wiring Diagrams).

Quick Close not       a) Quick Close setting incorrect              a) Check that Quick Close setting is ON
working correctly.    b) Interrupt loop detector                    b) Check operation of Interrupt Loop detector
                      c) Defective Expansion board                  c) Replace defective Expansion board

Anti-Tailgating not   a) Anti-Tail setting incorrect                a) Check that Anti-Tail setting is ON
working correctly.    b) Interrupt loop detector                    b) Check operation of Interrupt Loop detector
                      c) Defective Expansion board                  c) Replace defective Expansion board

AUX Relay not         a) AUX Relay setting incorrect                a) Check AUX Relay switches settings
working correctly.                                                  b) Check that wiring is connected to either N.O. and COM or to N.C. and COM.
                      b) AUX Relay wiring incorrect
                      c) Defective Expansion board                  c) Set AUX Relay to another setting and test. Replace defective expansion
                                                                       board.



                                                                        42


                                                           ACCESSORIES


                                                                                                                           INTERNET PROTOCOL
                                                                                                                             ACCESS CONTROL
    UNIVERSAL REMOTE CONTROLS             SECURITY+ 2.0™ LEARNING REMOTE CONTROLS                                                 IPAC
     813LM                                            894LT
                    811LM                                                          LIFTMASTER INTERNET GATEWAY
                                                                                             828LM
                                           892LT




                                                           LIFTMASTER DOOR AND GATE MONITOR
                                                                    Model 829LM
                  PLUG IN LOOP DETECTOR
                       LOOPDETLM




                                                                                                             HEATER KIT ACCESSORY AC/DC
3 BUTTON CONTROL STATION                                      LIFTMASTER ELITE SERIES                                 HTRNB
                                                                 MAGLOCK PACKAGE
       02-103
                             STOP BUTTON                          MG1300RLYPKG
                               AEXITP




       PLATE FOR POST                STEEL STAND FOR MOUNTING                                      VGROOVE POWER WHEELS
     MOUNTING OPERATOR                    TO CONCRETE PAD
            MPEL                                MSEL




                                                                                                   LONG GATE KIT (NOT SHOWN)
                                                                                                   Adjusts gate travel up to 51 feet
                                                                                                                Q160


                                                           ENTRAPMENT PROTECTION

  LiftMaster Monitored Through Beam Photoelectric Sensor (LMTBU)            Small Profile Channel - Aluminum (8 ft) (S50CHAL)*
  LiftMaster Monitored Retro Reflective Photoelectric Sensor (LMRRU)        Edge Cutting Tool (ETOOL)**
  LiftMaster Monitored Wireless Edge Kit (Transmitter and Receiver)         Wraparound Square Monitored Edge (4 ft) (WS4)**
  (LMWEKITU)                                                                Wraparound Square Monitored Edge (5 ft) (WS5)**
  LiftMaster Monitored Wireless Edge Transmitter (LMWETXU)                  Wraparound Square Monitored Edge (6 ft) (WS6)**
  Large Profile Monitored Edge (L50)*                                       Wraparound Round Monitored Edge (4 ft) (WR4)**
  Large Profile Ends Kit (pair) (L50E)**                                    Wraparound Round Monitored Edge (5 ft) (WR5)**
  Large Profile Channel - PVC (8 ft) (L50CHP)**                             Wraparound Round Monitored Edge (6 ft) (WR6)**
  Large Profile Channel - Aluminum (8 ft) (L50CHAL)**
  Small Profile Monitored Edge (S50)*
  Small Profile Ends Kit (pair) (S50E)*                                     * Available November 2015
  Small Profile Channel - PVC (8 ft) (S50CHP)*                              ** Available early 2016

                                                                       43


                                                                     REPAIR PARTS

                                               NOT SHOWN
 #41 Chain (10 feet)                                                                19-41240D
 #40 Chain (10 feet)                                                                19-40240D
 #41 Chain (Nickel Plated)                                                          19-41240D-NP
 #41 Master Link                                                                    19-50307                          Cover
                                                                                                                      K77-37708
 #40 Master Link                                                                    19-50310
 Plastic Standoffs for main control board (10 per bag)                              K77-37683
 Wire Harnesses (main board to power board, main board to ground, main board to     K77-37693
 transformer, and power board to transformer)
 Wire Harness (main board to expansion board)                                       K94-34778
 Reset Switch with ID                                                               K94-37468
 Hardware Kit (chain bolt and chain bracket)                                        K77-36764
 Chain Bolt                                                                         K07-50637

                                                                                                                              Drive Belt
                                                                Limit Switch Assembly                                         K16-4L360
                                                                K76-37306
                 Limit Switch Sprocket                                                                                    1 HP ONLY
                 K15-35B13AXR
                                                                                                          Gear Pulley
                                                                                                          K17-50095
                                                                                      RPM CUP
                                                                                      K13-32087
Limit Switch Chain                                                                             RPM Encoder
K19-35056                                                                                      Board
                              Drive Sprocket                                                   K2A0878
                              K15-41B25LGH

                                             Limit Switch                                                Drive Belt
                                             K23-50099                                                   K16-4L230
                                                                                                                                                     Motor Pulley
                                                                                                                                                     K17-50098


                         Limit Switch                                             Capacitor                                                   1/2 HP ONLY
                         Drive Sprocket                                           K29C-65AU2415
  Idler Pulley           K15-35B17LGF
  Assembly                                               Transformer
  K75-50090
                        Gear Reducer and Brake           K21-14182
                        K32-37349
            Alarm
            K94-37461


Antenna and                  Power Board,1 Phase
Coaxial Cable                K1D8402-1CC                                                                                                            Motor
K77-37638                                                                                                                                           K20-1050B-1RSX



                                                                                                             Chassis
                                                                                                             K73-37199
                                                         Expansion Board
                                                         K1D8387-1CC
                                                                                                   Electrical Box                 1 HP ONLY
                                                                                                   Assembly
                                                                                                   K75-37300-1                                   Motor
                                                                                                                                                 K20-1050B-1RSX

                                                                                                     Brake Assembly
                              Main Control Board                                                     K77-37710
                              K1D6761-1CC

   Dust Guard                                      Junction Box with On/Off
   K13-34729                                       Switch and Receptacle
                                                   K77-37709
                                                                              44


                                                                  WARRANTY

                              7 YEAR RESIDENTIAL / 5 YEAR COMMERCIAL LIMITED WARRANTY
LiftMaster (“Seller”) warrants to the first purchaser of this product, for the structure in which this product is originally installed, that it is free from
defect in materials and/or workmanship for a period of 7 year residential/ 5 year commercial from the date of purchase [and that the SL3000U is free
from defect in materials and/or workmanship for a period of 7 year residential/ 5 year commercial from the date of purchase]. The proper operation of
this product is dependent on your compliance with the instructions regarding installation, operation, maintenance and testing. Failure to comply
strictly with those instructions will void this limited warranty in its entirety.
If, during the limited warranty period, this product appears to contain a defect covered by this limited warranty, call 1-800-528-2806, toll free, before
dismantling this product. Then send this product, pre-paid and insured, to our service center for warranty repair. You will be advised of shipping
instructions when you call. Please include a brief description of the problem and a dated proof-of-purchase receipt with any product returned for
warranty repair. Products returned to Seller for warranty repair, which upon receipt by Seller are confirmed to be defective and covered by this limited
warranty, will be repaired or replaced (at Seller’s sole option) at no cost to you and returned pre-paid. Defective parts will be repaired or replaced with
new or factory-rebuilt parts at Seller’s sole option.
ALL IMPLIED WARRANTIES FOR THE PRODUCT, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE 7 YEAR RESIDENTIAL/ 5
YEAR COMMERCIAL LIMITED WARRANTY PERIOD SET FORTH ABOVE [EXCEPT THE IMPLIED WARRANTIES WITH RESPECT TO
THE SL3000U, WHICH ARE LIMITED IN DURATION TO THE 7 YEAR RESIDENTIAL/ 5 YEAR COMMERCIAL LIMITED WARRANTY
PERIOD FOR THE SL3000U], AND NO IMPLIED WARRANTIES WILL EXIST OR APPLY AFTER SUCH PERIOD. Some states do not
allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. THIS LIMITED
WARRANTY DOES NOT COVER NON-DEFECT DAMAGE, DAMAGE CAUSED BY IMPROPER INSTALLATION, OPERATION OR CARE
(INCLUDING, BUT NOT LIMITED TO ABUSE, MISUSE, FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTENANCE,
UNAUTHORIZED REPAIRS OR ANY ALTERATIONS TO THIS PRODUCT), LABOR CHARGES FOR REINSTALLING A REPAIRED OR
REPLACED UNIT, OR REPLACEMENT OF BATTERIES.
THIS LIMITED WARRANTY DOES NOT COVER ANY PROBLEMS WITH, OR RELATING TO, THE GATE OR GATE HARDWARE,
INCLUDING BUT NOT LIMITED TO THE GATE SPRINGS, GATE ROLLERS, GATE ALIGNMENT OR HINGES. THIS LIMITED
WARRANTY ALSO DOES NOT COVER ANY PROBLEMS CAUSED BY INTERFERENCE. ANY SERVICE CALL THAT DETERMINES THE
PROBLEM HAS BEEN CAUSED BY ANY OF THESE ITEMS COULD RESULT IN A FEE TO YOU.
UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES ARISING IN
CONNECTION WITH USE, OR INABILITY TO USE, THIS PRODUCT. IN NO EVENT SHALL SELLER’S LIABILITY FOR BREACH OF
WARRANTY, BREACH OF CONTRACT, NEGLIGENCE OR STRICT LIABILITY EXCEED THE COST OF THE PRODUCT COVERED
HEREBY. NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS
PRODUCT.
Some states do not allow the exclusion or limitation of consequential, incidental or special damages, so the above limitation or exclusion may not
apply to you. This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state.