         WARNING                                                                                  WARNING
CLUTCH ADJUSTMENT
   CAUTION
(BELT DRIVE MODEL OPERATORS)                                                                           WARNING
1   Remove the cotter pin from the clutch nut on the clutch shaft.       To avoid SERIOUS personal INJURY or DEATH from
                                                                         electrocution:
2   Turn the clutch nut to release tension.                              • Disconnect electric power BEFORE performing ANY
                                                                           adjustments or maintenance.
3   Re-tighten the clutch nut until there is just enough tension
    to permit smooth operation of the door and to allow the
    clutch to slip if the door is obstructed.
                                                                                           1           2
4   Secure the clutch nut with the cotter pin.


                                                                                      4
 AVERTISSEMENT                                                                          3
                                                                                       AVERTISSEMENT
ADJUST TORQUE LIMITER CLUTCH (MODEL GT)
    ATTENTION                                                                              AVERTISSEMENT
1 Loosen
   reducer.
            set screws of torque adjustment nut on the gear


2 Back  off torque nut until there is very little tension on the
  belleville washers.

3 Tighten  torque nut gradually until there is just enough tension
  to permit the operator to move the door smoothly through a                              Torque Nut
                                                                                          Set Screws
    complete open/close cycle, but to allow the reducer to slip if
    the door is obstructed.

4 Re-tighten  the set screw that is directly over the flat portion
  of the shaft.


MODEL GH (OPTIONAL MODIFICATION)

1 Loosen set screws on clutch nut.
2 ADVERTENCIA
  Back off clutch nut until there is very little tension on the
  clutch spring.
                                                                                      (3) Set Screws

                                                                                           ADVERTENCIA
3 Tighten clutch nut gradually until there is just enough tension
  to permit the operator to move the door smoothly but to allow
  PRECAUCIÓN
   the clutch to slip if the door is obstructed. When the clutch is                            ADVERTENCIA
   properly adjusted, it should generally be possible to stop the
    door by hand during travel.


AUXILIARY REVERSAL SYSTEM / RPM SENSOR
The Auxiliary Reversal System is designed to protect the door and

                                                                                                                                          ADJUSTMENT
motorized operator. It is NOT a substitute for an entrapment                       LOSE       OPEN

sensing device.
Feature: This feature utilizes the RPM sensor connected to the logic
board to detect when the clutch slips and reverses the door (clutch
must be properly adjusted). In addition, the RPM eliminates the
need for a centrifugal switch on single phase motors.
Benefit: The Auxiliary Reversal System reverses the operator upon                                                     RPM Sensor
hitting an obstruction, preventing excessive door and operator
damage. UL325 requires the use of monitored entrapment
protection devices for primary entrapment protection. By removing
the centrifugal switch on single phase motors, the leading cause of
motor failures is eliminated. (Auxiliary Reversal System is not
applicable on GH models unless the clutch modification is                                               Logic Board
installed.)
NOTE: This feature is automatically learned and does not require
programming.                                                        23                                                       Adjustment


             WARNING
          TESTING                                                                                             WARNING
          Apply power to the operator.
               CAUTION
          When power is applied to the operator, the following LED’s will                                       WARNING
          illuminate: STOP, CLOSE, OPEN, LMEP, 24Vac, RADIO, DATA,                     To avoid SERIOUS personal INJURY or DEATH:
          TIMER ENABLE, OLS MID, SLS, CLS, and MAS. Once the power                     • Disconnect electric power BEFORE performing ANY
          up process is completed (approximately 2-3 seconds) only the                   adjustments or maintenance.
          appropriate LED’s will continue to be lit:                                   • ALL maintenance MUST be performed by a trained door
          • Between limits: 24Vac and STOP                                               systems technician.
          • Fully closed position: 24Vac, STOP, CLS and SLS
          • Fully opened position: 24Vac, STOP and OLS                                 TEST 3-BUTTON CONTROL STATION
          Additional LED’s will light when device(s) are activated.                    1. Press OPEN button. (The door should move in the open
          NOTE: When the power up process is over, the MAS LED will                       direction.)
          blink a code indicating the version of firmware. If the selector dial        2. Press STOP button. (The door should stop.)
          is in the DIAG, OPTN, or PROG position, the MAS will not provide             3. Press and hold the CLOSE button. (The door should move in
          this code. After the code has been provided the MAS LED will go                 the close direction.)
          AVERTISSEMENT
          out.                                                                                        AVERTISSEMENT
                                                                                       4. Release CLOSE button. Door should stop if in C2 or D1 mode.
                                                                                          Door will reverse to full open position in E2 mode. The door
                                                                                          should continue closing in all other modes.
            ATTENTION
          TEST PHOTOELECTRIC SENSORS (IF APPLICABLE)                                                    AVERTISSEMENT
                                                                                       5. Press STOP button. (The door should stop.)
          1. Open the door.                                                            TEST LIMIT ADJUSTMENT
          2. Place an obstruction in the path of the photoelectric sensors.            1. Press OPEN button. (The door should open.)
             The LMEP LED will blink on the logic board.                               2. Allow the door to fully open.
          3. Press and hold the CLOSE button. The door should not close.               3. Press and hold the CLOSE button. (The door should close.)
          4. Remove the obstruction.                                                   4. Allow the door to fully close.
          5. Press and hold the CLOSE button. Door should close.                       5. If the limits are not set properly, remove power and adjust
             If the LMEP is activated while closing the door should reverse.              limits (refer to Limit Adjustment section).
          TEST EDGE SENSORS (IF APPLICABLE)
          1. Open door.
          2. Place an obstruction in the path of the door.
          3. Press and hold the CLOSE button. The door should stop and/or
             reverse.
          4. Remove obstruction and hold the CLOSE button. Door should
             fully close.
          NOTE: The Logic 5 control board will automatically learn the
          LMEP device once it is properly connected. If the LMEP device is             IMPORTANT NOTES:
            ADVERTENCIA
          misaligned, activated, or disconnected the LMEP LED on the logic                               ADVERTENCIA
                                                                                       • Be sure you have read and understand all safety instructions
                                                                                         included in this manual.
          control board will blink on and off. You can close the door by
          entering the Restricted Close (RC) mode by holding the close                 • Be sure the owner or person(s) responsible for operation of the
                                                                                         door have read and understand the safety instructions, know
          button. The operator will begin closing after 5 seconds and will
          PRECAUCIÓN
          continue to close to the Close Limit or when the close button is
                                                                                                           ADVERTENCIA
                                                                                         how to electrically operate the door in a safe manner and how
          released.                                                                      to manually disconnect the door from the operator.
          To unlearn the LMEP device, turn the selector dial to DIAG, push
          and hold the stop button until the MAS LED flashes. Without the
          LMEP device connected the only mode of operation will be B2, D1
TESTING




          or E2.




          Testing                                                                 24


MANUAL RELEASE
EMERGENCY DISCONNECT SYSTEM
MODEL GT AND T                                                                                   WARNING
                                                                        To prevent possible SERIOUS INJURY or DEATH from a falling
TO DISCONNECT DOOR FROM OPERATOR                                        door or arm:
The door should be in the fully closed position if possible.                                  CAUTION
                                                                        • DO NOT stand under the door arm when pulling the
1   Pull emergency release handle straight down. Emergency
    disconnect will open.
                                                                          emergency release.
                                                                        • If possible, use emergency release handle to disengage trolley
                                                                          ONLY when door is CLOSED. Weak or broken springs or
TO RECONNECT DOOR ARM TO TROLLEY                                          unbalanced door could result in an open door falling rapidly
2   Lift free end of door arm to trolley. Pull emergency release
    handle to allow arm to engage roll pin. Release handle.
                                                                          and/or unexpectedly.
                                                                        • NEVER use emergency release handle unless doorway is clear
    Emergency disconnect will close.                                      of persons and obstructions.




                                                                            1            AVERTISSEMENT

                                                                                            ATTENTION



                                                                               2                                     NOT
                                                                                                                        ICE




EMERGENCY DISCONNECT SYSTEM
MODEL APT
TO DISCONNECT DOOR FROM OPERATOR                                                           ADVERTENCIA
The door should be in the fully closed position if possible.
1   Pull down on the emergency release handle and raise or



                                                                                                                                               MANUAL RELEASE
    lower the door manually.                                                              PRECAUCIÓN
TO RECONNECT DOOR ARM TO TROLLEY
2   The trolley will reconnect on the next UP or DOWN operation,
    either manually or by using the door control or remote.
                                                                                                                1


                                                                                                      NOT
                                                                                                         ICE




                                                                   25                                                         Manual Release


                                                                                                                  WARNING
                 EMERGENCY DISCONNECT SYSTEM
                 MODEL H, GH, J, AND HJ                                                                         CAUTION
                                                                                           To prevent possible SERIOUS INJURY from a moving chain:
                 This operator has provisions for manually operating the door in           • DISCONNECT electric power to the operator BEFORE manually
                 case of emergency or power failure. Refer to the appropriate                operating your door.
                 instructions below for your model operator.                               • If possible, use emergency disconnect ONLY when door is
                                                                                             CLOSED. Weak or broken springs or unbalanced door could
                                                                                             result in an open door falling rapidly and/or unexpectedly.
                                                                                           • NEVER use emergency disconnect unless doorway is clear of
                 MODEL H AND GH                                                              persons and obstructions.
                 These operators are equipped with a manual hoist. An electrical
                 interlock will disable the electrical controls when the hoist is
                                                                                            H and GH
                 used. To operate the hoist:
                                                                                                                    3
                 1   Pull the disconnect chain (sash chain) to engage the hoist                           AVERTISSEMENT
                     mechanism. The disconnect chain may be locked in position
                     by slipping the end through the keyhole of the chain keeper
                     mounted on the wall.                                                                    ATTENTION
                 2   Operate the door in the desired direction by pulling on one
                     side or the other of the continuous loop hoist chain.
                                                                                             2
                                                                                                                1
                 3   The disconnect chain must be released from the chain
                     keeper before the door will operate again electrically.


                 MODEL J
                 This operator has a floor level disconnect chain to disconnect the
                 door from the door operator.
                                                                                               J
                                                                                                3
                 1   To disengage, pull the disconnect chain (sash chain) and
                     secure in the disengaged position by slipping the end
                     through the keyhole bracket mounted on the wall.
                                                                                                            1                          2
                 2   The door may now be pushed up or pulled down manually.
                                                                                                             ADVERTENCIA
                 3   Release the disconnect chain to operate the door again
                     electrically.
                                                                                                           PRECAUCIÓN
                 MODEL HJ
                 This operator includes both a floor level disconnect chain
MANUAL RELEASE




                 (sash chain) to disconnect the door from the door operator and a
                 disconnect chain with manual hoist to electrically disable the              HJ
                 operator controls.
                 1   Pull the disconnect chain to engage the hoist mechanism.
                                                                                               4
                     The disconnect chain may be locked in position by slipping
                                                                                                                                            4
                     the end through the keyhole of the chain keeper mounted on
                     the wall.                                                                              3
                 2   To disengage, pull the disconnect chain and secure in the
                     disengaged position by slipping the end through the keyhole
                     bracket mounted on the wall.
                 3   Operate the door in the desired direction by pulling on one
                     side or the other of the continuous loop hoist chain.
                 4   Release the disconnect chain to operate the door again                                          2
                     electrically.
                                                                                                                                1
                 Manual Release                                                       26


PROGRAMMING
INTRODUCTION TO PROGRAMMING
Many programmable functions require that a LiftMaster
Entrapment Protection (LMEP) device be installed in order to
function. Refer to the Entrapment Protection section.

Before programming the logic board, set the operator’s open and                                                    LOGIC BOARD PUSH BUTTONS (OPEN, CLOSE, STOP)
close limits. LEDs on the logic board are provided to assist setting                                               Open, Close and Stop buttons are mounted directly on the logic
the limits. As each limit is activated the corresponding LED will                                                  board. Thus, making it easy to program as well as have door
light up. The abbreviations are Open Limit Switch (OLS), Close                                                     control at the electrical box.
Limit Switch (CLS) and Sensing Limit Switch (SLS). Refer to page
19 for limit switch adjustment instructions.                                                                       Either the stop control or a jumper MUST be wired between
                                                                                                                   terminals 4 and 5 for the on board push buttons to function.
When power is applied to the operator, the following LED’s will
illuminate: STOP, CLOSE, OPEN, LMEP, 24Vac, RADIO, DATA,
TIMER ENABLE, OLS MID, SLS, CLS, and MAS. Once the power
up process is completed (approximately 2-3 seconds) only the
appropriate LED’s will continue to be lit (i.e., STOP, 24Vdc, limit
LED(s) if limit(s) is activated).
NOTE: When the power up process is over, the MAS LED will
blink a code indicating the version of firmware. If the selector
dial is in the DIAG, OPTN, or PROG position, the MAS will not
provide this code. After the code has been provided the MAS LED
will go out.


LOGIC BOARD OVERVIEW

                                                                                                                                                         DATA
                                                                SLOT




                    Optional Auxiliary
                                                                1




                    Card Receptacles
                                                                SLOT




                                                                                                                                                24VAC      14
                                                                2




                                                                                                                                                POWER           Single Phase &
                   Motor Direction Jumper                                                                                                       24VAC      13   Three Phase Jumper
                                                                                                                                                 TIMER
                                                                                                                                                DEFEAT
                                                                                                                                                           12
                           Maximum Run                                               OLS                                                                        Maintenance Alert
                                                                              REV
                                                                       STD




                                                                                                                            1-PHASE

                                                                                                                                      3-PHASE




                            Timer Button                                                                                                        COMMON     11   System Button for
                                                                                      MID
                                                                                                                                                 MAS            Programming
                                                                         DIRECTION
                                                                           MOTOR




                                                                                      SLS                                                                  10

                                                                                      CLS
                                                                                                                                                LMEP:       9
                    Radio Learn Button                                                                                                                          Open Button
                                                                                             MRT         MID        TTC      TIMER
                                                                                                                                                EDGE:
                                                                                                                            ENABLE                          8
                                                                                                                                                OPEN
                                                                                                                                                                Close Button
                                                                                     RADIO    1           2          3                                      7
                                                                                                                                                CLOSE
                  Mid Stop Learn Button                                                                                                                     6   Stop Button




                                                                                                                                                                                                   PROGRAMMING
                                                                                                                                                STOP        5
                                                                                                     T         TS
                                                                                              E2                     FSTS
                                                                                                                                                            4
                                                                                             D1                                                 COMMON
                                                                                                                         DIAG
                                                                                                                                                                   Control Wiring
                          Timer-To-Close                                                     C2                          OPTN                               3
                                                                                                                                                                   Terminal Block
                            Learn Button                                                      B2                     PROG
                                                                                                                                                            2

                                                                                                   RELAY       A                                  SBC       1
                                                                                                   RELAY       B




                                   Selector Dial
                                   (used for programming                               Main Motor Control Harness Connection
                                   and selecting wiring type)




                                                                                                         27                                                                          Programming


              DETERMINE AND SET WIRING TYPE
              Read the descriptions of the different wiring types to determine which setting will be correct for each application. Once the wiring type
              is determined, set the selector dial accordingly.

              LIFTMASTER MONITORED ENTRAPMENT PROTECTION (LMEP)                          LIFTMASTER MONITORED ENTRAPMENT PROTECTION (LMEP)
              DEVICE IS REQUIRED                                                         DEVICE IS RECOMMENDED
              A LiftMaster Entrapment Protection (LMEP) device is required for           A LiftMaster Entrapment Protection (LMEP) device is
              the following wiring types.                                                recommended for the following wiring types.

              B2   Momentary contact to open, close and stop, plus wiring for            C2   Momentary contact to open and stop with constant pressure
                   sensing device to reverse and auxiliary devices to open and                to close, open override plus wiring for sensing device to
                   close with open override. Programmable mid stop available                  reverse. Programmable mid stop available with this wiring
                   with this wiring type. Compatible with 3-Button Station,                   type. Compatible with 3-Button Station and 1-Button
                   1-Button Station, 1 and 3-Button Remote Control.                           Station.
              TS (TIMER SECURE)                                                          E2   Momentary contact to open with override and constant
                    This mode will attempt to close the door from any position                pressure to close. Release of close button will cause door to
                    except when fully closed, or when a safety input is present.              reverse (roll-back feature) plus wiring for sensing device to
                    The stop button will not disable the Timer-To-Close at any                reverse. Compatible with 3-Button Station.
                    position. To disable the Timer-To-Close in this mode,
                    installation of a defeat switch is required (see wiring              D1   Constant pressure to open and close with wiring for sensing
                    diagram).                                                                 device to stop. Compatible with 2 or 3-Button Station.
                    Momentary contact to open, close, and stop with open
                    override and Timer-To-Close. Every device that causes
                    door to open, including a reversing device, activates the
                    Timer-To-Close. Auxiliary controls can be connected to open                     SELECTOR DIAL
                    input to activate the Timer-To-Close. If the timer has been
                    activated, the open button and radio control can recycle the                                          T   TS
                    timer. The Timer-To-Close will function from the                                                 E2
                                                                                                                                   FSTS
                    programmable mid stop with this wiring type. Compatible                                     D1                  DIAG
                    with 3-Button Station, 1-Button Station and 1 and 3-Button
                    Remote Control.                                                                            C2                   OPTN

                    NOTE: A Programmable “Car Dealer Mode” available.                                           B2                 PROG
              T     Momentary contact to open, close, and stop, with open
                    override and Timer-To-Close. Every device that causes
                    the door to open, except any sensing edge input device,
                    activates the Timer-To-Close. Auxiliary controls can be          IMPORTANT NOTES:
                    connected to open input to activate the Timer-To-Close.          1. External interlocks may be used with all functional modes.
                    If the Timer-To-Close has been activated, the open button
                    and radio control can recycle the timer. The stop button will    2. Auxiliary devices are any devices that have only dry contacts.
                    deactivate the timer until the next command input. The              Examples: loop detector, pneumatic or electrical treadles, radio
                    Timer-To-Close will function from the programmable                  controls, one button stations, pull cords, etc.
                    mid stop with this wiring type. Compatible with 3-Button         3. Open override means that the door may be reversed while
                    Station,1-Button Station and 1 and 3-Button Remote                  closing by activating an opening device without the need to use
                    Control.                                                            the stop button first.
                    NOTE: Programmable “Car Dealer Mode” available.                  4. When the door is in a stopped position other than fully closed,
              FSTS Momentary button contact for open, close and stop                    and an LMEP or EDGE input is activated, the Restricted Close
                    programming. User set mid stop. User set Timer-To-Close.            (RC) feature will allow a close command when the close button
PROGRAMMING




                    The single button station opens the door to the full                is pressed and held. The operator will begin closing after 5
                    open limit bypassing the mid stop and activates the                 seconds. If the close button is released the door will stop.
                    Timer-To-Close, putting the operator in TS mode until the
                    door reaches the down limit, or is stopped in travel. At            When in E2 mode, the door will move to the fully open position.
                    which time the operator enters the B2 mode.
                    Compatible with 3-Button Station, 1-Button Station, 1 and
                    3-Button Remote Control. A 1-Button remote control in
                    FSTS mode will open only with the Timer-To-Close,
                    bypassing a programmed mid stop. The Timer-To-Close will
                    reset and reverse when closing.




              Programming                                                           28


PROGRAMMING REMOTE CONTROLS

                                                              WARNING                                                                                                                                                      WA
 To prevent possible SEVERE INJURY or DEATH:
                                                            CAUTION
 • Install a LiftMaster Monitored Entrapment Protection (LMEP)
   device.
                                                               • Activate door ONLY when it can be seen clearly, is properly
                                                                 adjusted and there are no obstructions to door travel.
                                                                                                                                                                                                                            W
 • NEVER permit children to operate or play with door control              • ALWAYS keep door in sight until completely closed. NEVER
   push buttons or remote controls.                                          permit anyone to cross the path of closing door.


Built in 3-channel, Security✚ 2.0TM radio receiver that allows you         3. Press and release the RADIO button to complete the
to add as many as 90 remote control devices and as many as 30                 programming. The RADIO programming mode will exit if no
touch code devices.                                                           activity is performed within 30 seconds. The MAS and RADIO
NOTE: The following programming requires a LiftMaster                         LED’s will flash briefly to indicate the RADIO has exited the
Monitored Entrapment Protection (LMEP) device.                                programming mode for remote controls and touch code
                                                                              devices. The RADIO will remain in program mode for another
STANDARD REMOTE CONTROL                                                       150 seconds for MyQ devices and then will completely exit
1. To enter programming press and release the RADIO button on                 with no activity.
   the logic board (RADIO LED will light).
                                                      AVERTISSEMENT
2. Press and hold the remote control button until the RADIO LED
                                                                           NOTICE: To comply with FCC and/or Industry Canada (IC) rules, adjustment or modifications of this
                                                                           transceiver are prohibited. THERE ARE NO USER SERVICEABLE PARTS. Any changes or modifications
                                                                                                                                                                                                             AVERT
                                                                           not expressly approved by the party responsible for compliance could void the user’s authority to
   flashes rapidly, then release remote control button. The RADIO          operate the equipment. This device complies with Part 15 of the FCC rules and IC RSS-210. Operation
   LED will then remain on solid after releasing the button. Repeat        is subject to the following two conditions: (1) this device may not cause harmful interference, and (2)
                                                                           this device must accept any interference received, including interference that may cause undesired
   to add additional remote control(s).                  ATTENTION         operation. This Class B digital apparatus complies with Canadian ICES-003.                                                           AVER

SINGLE BUTTON REMOTE CONTROL PROGRAMMED AS
A SINGLE BUTTON CONTROL (SBC)
This function programs a remote control as a wireless single




                                                                                                                                                    SLOT
button control. This function will work in the following modes:
   In B2 mode, operation is OPEN/STOP/CLOSE/REVERSE/STOP.




                                                                                                                                                    1
   In T and TS modes, operation is OPEN/STOP/CLOSE/REVERSE/
   STOP and Timer-To-Close start/refresh. NOTE: If Car Dealer
   mode is enabled, SBC will be open only stopping at the Open




                                                                                                                                                    SLOT
   Mid-Stop.




                                                                                                                                                    2
   In FSTS mode, operation is OPEN with Timer-To-Close
   start/refresh only, bypassing a programmed Open Mid Stop.                              RADIO                                                                          OLS




                                                                                                                                                                  REV
                                                                                                                                                           STD
1. Press and release the RADIO button on the logic board                                                                                                                  MID




                                                                                                                                                             DIRECTION
   (RADIO LED will light).


                                                                                                                                                               MOTOR
                                                                                                                                                                          SLS

2. Press and release the SBC externally wired button or TTC on                                                                                                            CLS

   the logic board (RADIO LED flashes rapidly and then remains                                                                                                                   MRT         MID        TT

   on solid).                                           ADVERTENCIA                                                                                                      RADIO    1           2          3
                                                                                                                                                                                                                 ADVE
3. Press and hold the remote control button until the RADIO LED
   flashes rapidly. The RADIO LED will then remain on solid after
   releasing.
                                                       PRECAUCIÓN                                                                                                                        T         TS
                                                                                                                                                                                                                           ADV

                                                                                                                                                                                                             PROGRAMMING
                                                                                                                                                                                  E2
4. Press and release the RADIO button on the logic board (RADIO                                                                                                                  D1
                                                                                                                                                                                                         F



   LED flashes rapidly and then turns off). The programming                                                                                                                      C2

   mode is exited if no activity is performed within 30 seconds                                                                                                                   B2                     P


   The MAS and RADIO LED’s will flash briefly to indicate the
   RADIO has exited the programming mode for remote controls                                                                                                                           RELAY
                                                                                                                                                                                       RELAY
                                                                                                                                                                                                   A
                                                                                                                                                                                                   B

   and touch code devices. The RADIO will remain in program
   mode for another 150 seconds for MyQ® devices and then will
   completely exit with no activity.
NOTE: Single button remote control is not supported with D1 and
E2 wiring modes. C2 mode will only open and stop while opening.

TO ERASE REMOTE CONTROLS
Press and hold the RADIO button on the logic board until the
RADIO LED flashes rapidly (approximately 5 seconds).
All remote controls will be erased.

                                                                      29                                                                                                 Programming


              PROGRAMMING REMOTE CONTROLS
              NOTE: The following programming requires a LiftMaster                                                                                                 REMOTE CONTROL PROGRAMMING FEATURE
              Monitored Entrapment Protection (LMEP) device.                                                                                                        Program Remote Controls from the 3-button control station
              Your Security✚ 2.0TM or dip switch remote control can be                                                                                              (3BCS).
              programmed to operate as a 3-button wireless control station:                                                                                         This feature allows the user to add additional remote controls
              the large button will open the door, the middle button will close                                                                                     from the 3BCS. By default the remote control learn option is off.
              the door, and the third button will stop the door’s movement.                                                                                         NOTE: Requires access to the operator electrical box to enable or
              You may set up this feature as follows:                                                                                                               disable this feature.
              1. To enter programming press and release the RADIO button on                                                                                         To turn this feature on:
                 the logic board (the RADIO LED will light).                                                                                                        1. Turn the SELECTOR DIAL to PROG.
              2. To program the OPEN button to a remote control press and                                                                                           2. Press and release the RADIO button. The RADIO LED will be lit.
                 release the OPEN button on the logic board. The RADIO LED                                                                                          3. Press and release the MID button. The RADIO LED will flash
                 will flash and then stay on solid. Then press the corresponding                                                                                       quickly 6 times.
                 button on the remote control. The RADIO LED on the logic
                                                                                                                                                                    4. Press and release the RADIO button. The RADIO LED will turn
                 board will flash, this confirms that the remote control has been
                                                                                                                                                                       off.
                 programmed. (By programming the remote you use 1 channel
                 of the 90 channels on the radio receiver.)                                                                                                         5. Return the SELECTOR DIAL to the desired wiring type.
              3. To program the CLOSE button to a remote control press and                                                                                          To add remote controls from the 3BCS:
                 release the CLOSE button on the logic board. The RADIO LED                                                                                         1. With the door in the fully closed position (close limit activated),
                 will flash and then stay on solid. Then press the corresponding                                                                                       press and hold STOP.
                 button on the remote control. The RADIO LED on the logic                                                                                           2. While holding STOP, press and hold CLOSE.
                 board will flash, this confirms that the remote control has been                                                                                   3. While holding STOP and CLOSE, press and hold OPEN.
                 programmed. (By programming the remote you use 1 channel                                                                                           4. Release all three buttons once the MAS LED has lit.
                 of the 90 channels on the radio receiver.)                                                                                                         5. Learn a remote control by one of the following methods:
              4. To program the STOP button to a remote control press and                                                                                              a.     Programming a standard single button/single function
                 release the STOP button on the logic board. The RADIO LED                                                                                                    remote control, push and hold the remote control button
                 will flash and then stay on solid. Then press the corresponding                                                                                              until the MAS LED goes out. Repeat steps 1 through 4 to
                 button on the remote control. The RADIO LED on the logic                                                                                                     add additional remote controls.
                 board will flash, this confirms that the remote control has been                                                                                      b.     Programming a 3-button/three function remote control
                 programmed. (By programming the remote you use 1 channel                                                                                                     (OPEN/CLOSE/STOP), first push the button on the 3BCS
                 of the 90 channels on the radio receiver.)                                                                                                                   (Example: OPEN) and then press and hold the button on
              5. After learning remote controls press the RADIO button on the                                                                                                 the remote control (Example: large button) that you want
                 logic board (RADIO LED will turn off). NOTE: If no activity                                                                                                  to correspond with the selected (Example: OPEN)
                 within 30 seconds, the MAS and RADIO LED’s will flash briefly                                                                                                command until the MAS LED flashes and goes out.
                 to indicate the RADIO has exited the programming mode for                                                                                                    Repeat steps 1 through 4 to add additional buttons
                 remote controls and touch code devices. The RADIO will                                                                                                       (CLOSE AND STOP).
                 remain in program mode for another 150 seconds for MyQ®                                                                                            To turn this feature off:
                 devices and then will completely exit with no activity.
                                                                                                                                                                    1. Turn the SELECTOR DIAL to PROG.
                                                                                                                                                                    2. Press and release the RADIO button. The RADIO LED will be lit.
                                                                                                                                                                    3. Press and release the MRT button. The RADIO LED will flash
                                                                                                                                                                       quickly 3 times.
                                                                                                                                                        DATA
                                                               SLOT
                                                               1




                              Open
                                                                                                                                                                    4. Press and release RADIO button. The RADIO LED will turn off.
                                                                                                                                                                    5. Return SELECTOR DIAL to desired wiring type.
                                                               SLOT




                                               MER
                                                      EDGE:                                                                                    24VAC      14
                              Close           NABLE
                                                               2




                                                                                                                                                                    NOTE: Restoring the operator to Factory Default (see RESETTING
                                                                                                                                               POWER

                     OPEN                             OPEN                                                                                     24VAC      13
                                                                                                                                                TIMER
                                                                                                                                                          12

                                                                                                                                                                    FACTORY DEFAULTS) will also disable this feature. The remote
                                                                                                                                               DEFEAT
                                                                                    OLS
                                                                             REV
                                                                      STD




                                                                                                                           1-PHASE

                                                                                                                                     3-PHASE




                              Stop                                                   MID
                                                                                                                                               COMMON
                                                                                                                                                MAS
                                                                                                                                                          11
                                                                        DIRECTION




                                                                                                                                                                    controls will still be learned.
                                                                          MOTOR




                                                      CLOSE                          SLS                                                                  10

                                                                                     CLS
                                                                                                                                                           9
PROGRAMMING




                                                                                                                                               LMEP:

                    CLOSE                                                                   MRT         MID        TTC      TIMER
                                                                                                                           ENABLE
                                                                                                                                               EDGE:
                                                                                                                                                           8
                                                                                                                                               OPEN
                                                      STOP                          RADIO    1           2          3                                      7
                                                                                                                                               CLOSE
                                                                                                                                                           6

                                                                                                                                               STOP        5
                                                                                                    T         TS
                                                      COMMON                                 E2
                     STOP                                                                   D1
                                                                                                                    FSTS

                                                                                                                        DIAG
                                                                                                                                               COMMON
                                                                                                                                                           4

                                                                                            C2                          OPTN                               3
                                                                                             B2                     PROG
                                                                                                                                                           2

                                                                                                  RELAY       A                                  SBC       1
                                                                                                  RELAY       B




              Programming                                                                                                                                      30


PROGRAMMING MyQ® DEVICES (OPTIONAL)
To Program MyQ Devices:                                                   2. Press and hold the MAS button for 5-seconds. The RADIO LED
1. To enter proramming mode, press and release the RADIO button              will flash for approximately 5-seconds and the RADIO LED will
   on the logic board (the RADIO LED will light).                            turn off.
2. To program the MyQ device, place the MyQ device into learn             3. All MyQ devices are now erased.
   mode (see instructions for the specific MyQ device).                   To Erase One MyQ Device:
3. When the programming is complete the RADIO LED will turn off.          1. See instructions for the specific MyQ device to erase the
NOTE: If the programming is not completed within 3 minutes, the              programming.
program mode will be exited and the RADIO LED will turn off.              2. When the erase is complete, the MyQ device will be erased on the
To Erase All MyQ Devices:                                                    operator. The operator does not need to be reprogrammed to
1. Press and release the RADIO button on the logic board (the                erase the MyQ device.
   RADIO LED will light).                                                 NOTE: Power the operator to complete the erase operation.

MAINTENANCE ALERT SYSTEM (MAS)
Feature: An internal cycle counter will activate a flashing LED on the    programmed and the CLOSE button LED will flash once for every 3
3-button control station when the preset number of cycles or months       month increment programmed.
has elapsed (whichever occurs first). Setting this feature is optional.   To view how many cycles have elapsed since the last time the MAS
By default this feature will never activate. Logic 5 operators            was programmed, set the selector dial to DIAGNOSTIC and press
incorporate a self diagnostic feature built into the MAS LED. In          the MAS button. Press the OPEN button; the OPEN LED will flash
addition to indicating when routine maintenance is due, the MAS           once for every 5,000 cycles that has elapsed. Press the CLOSE
LED can be used to troubleshoot some problems with the operator.          button; the CLOSE LED will flash once for every (3) months that has
Benefit: The Maintenance Alert System (MAS) assists the installing        elapsed. Press the MAS button to exit. Turn the selector dial back to
dealer in setting up a routine maintenance program. Once                  desired wiring type.
programmed, the MAS notifies the end user (with a flashing LED on                                   SELECTOR DIAL
the 3-button station) when a preset number of cycles/months has
elapsed and scheduled maintenance is due.                                                                              T     TS
To Program:                                                                                                    E2
                                                                                                                                  FSTS
1. Close the door.                                                                                        D1                       DIAG
2. Turn the selector dial to PROGRAM.                                                                     C2                       OPTN
3. Press and release the MAS SET button.
                                                                                                          B2                      PROG
4. Press the STOP button once to clear the MAS memory.
5. Press the OPEN button once for every 5,000 cycles increments.
                                                                                 Operation will vary
   Press the CLOSE button once for every 3 month increments.                     depending on wiring                    T    TS
                                                                                                                E2
6. Press and release the MAS button to complete the programming.                 type                                             FSTS
   The on board LED will flash back the programmed settings. The                                          D1                       DIAG
   OPEN LED will flash once for every 5,000 cycles. The CLOSE LED                                         C2                       OPTN
   will flash once for every 3 months.
                                                                                                           B2                     PROG
7. Turn the selector dial back to the desired wiring type.
NOTE: If MAS LED flashes 2 or more flashes in a row followed by a
pause, an operator error occurred. Turn to page 35 to diagnose                                  3-BUTTON CONTROL STATION
problem.
Example: A door is installed with 30,000 cycle springs and has an                 Maintenance Alert LED
annual service contract. To set the MAS, turn selector dial to                                                       OPEN
PROGRAM, press MAS button, press the STOP button to clear the
memory and then press the OPEN button 6 times (30,000 cycles)


                                                                                                                                                        PROGRAMMING
and CLOSE 4 times (12 months). Press the MAS again to complete                                                       CLOSE
the programming. Turn the selector dial back to desired wiring type.
                                                                                                                     STOP
Special Notes about MAS: A 5th wire must be run to the control
station to activate the MAS LED. The MAS LED on the logic board is
always enabled. When the operator is serviced after the MAS LED
has started to flash, repeat the setup procedure to program in the        Press This                                   To Get This
number or cycles desired until the next service visit OR press and        OPEN
hold the MAS button for 5 seconds in the PROGRAM mode to reset                                  Adds 5,000 cycles to Maintenance Alert
the MAS with its current programmed value. To disable the MAS,                                  System Activation Counter.
follow the programming procedure above and press the STOP button CLOSE                          Adds 3 Months to Maintenance Alert System
to reset the counter to zero. Every time the operator leaves the close                          Activation Timer.
limit is counted as one cycle.
To view how many cycles are programmed into the MAS, set the              STOP                  Clears memory, sets Maintenance Alert
selector dial to DIAGNOSTIC and press the MAS button. The OPEN                                  System Activation Counter to 0 cycles and
button LED will flash once for every 5,000 cycle increment                                      0 months.
                                                                       31                                                                 Programming


              OPEN MID STOP
              Feature: The Mid Stop feature is to open the door to a preset
              point prior to the fully open position.
              Benefit: The door opens to a midpoint between open and close                                                              SELECTOR DIAL
              reducing heating and cooling costs. The door will not cycle fully,
              providing longer door and operator life.                                                                                           T   TS
              To Program:                                                                                                                   E2
                                                                                                                                                           FSTS
              1. Close the door.                                                                                                      D1                        DIAG
              2. Turn selector dial to PROGRAM.                                                                                                                 OPTN
                                                                                                                                      C2
              3. Press and release the MID button on logic board.
                                                                                                                                       B2                  PROG
              4. Press the OPEN button, wait until the door reaches the desired
                 mid stop height, then press and release the STOP button.
              5. Press and release the MID button to complete programming.                               Operation will vary
              6. Turn selector dial back to desired wiring type.                                         depending on wiring                     T   TS
                                                                                                         type                               E2
              NOTE: A momentary open command will open the door fully from                                                                                 FSTS

              the Mid Stop position. Once at the Mid Stop, photoelectric sensors                                                      D1                        DIAG

              and other entrapment protection devices will not open the door                                                         C2                         OPTN
              beyond the mid stop position, except in E2 mode. The Timer-To-                                                           B2                  PROG
              Close will work from the Mid Stop.
              To clear the Mid Stop set the selector dial to PROG and press and
              hold the MID button for 5 seconds. The MID LED will flash rapidly
              and turn off once the Mid Stop has been cleared. Turn selector
              dial back to desired wiring type.




                                                                        WARNING                                                                                                       WA
               To prevent possible SEVERE INJURY or DEATH:
                                                                          • Activate door ONLY when it can be seen clearly, is properly
                                                                      CAUTION
               • Install a LiftMaster Monitored Entrapment Protection (LMEP)
                 device.                                                    adjusted and there are no obstructions to door travel.                                                     WA
               • NEVER permit children to operate or play with door control             • ALWAYS keep door in sight until completely closed. NEVER
                 push buttons or remote controls.                                         permit anyone to cross path of closing door.


              TIMER-TO-CLOSE
              Feature: Timer automatically closes door after preset time. All        6. Press and release the TIMER button to complete programming.
              entrapment protection devices must be unobstructed.                       The OPEN/CLOSE button LEDs will flash to confirm the timer
              Benefit: The door will automatically close after preset amount of         setting. The OPEN LED will flash once for every second
              time. Great for apartment buildings, fire stations and other              programmed and the CLOSE LED will flash once for every 15
              applications where the end user wants the door to close                   seconds programmed.
              automatically after a specified amount of time.                        7. Turn the selector dial to desired timer wiring type
              Requirements: Must have at least one LiftMaster Monitored                 (TS ,T or FSTS).
                                                                 AVERTISSEMENT
              Entrapment Protection (LMEP) device installed (refer to page 20).      Example: To close the door after 70 seconds. Turn selector dial to                             AVERT
PROGRAMMING




              Wiring type must be set to TS, T or FSTS.                              PROGRAM, press and release the TIMER button, press and
              TO PROGRAM MANUALLY (METHOD 1):                                        release the STOP button to clear the timer, press and release the
                                                                                     CLOSE button four times for 60 seconds and press and release
              1. Close the door.
              2. Turn the selector dial to PROGRAM.
                                                                    ATTENTION        the OPEN button 10 times for 10 seconds. Press the TIMER                                       AVERT
                                                                                     button to finish programming the timer. Turn selector dial to
              3. Press and release the TIMER button on the logic board.
                                                                                     desired timer wiring type. (TS, T, FSTS).
              4. Press and release the STOP button to clear the timer.
              5. Press and release the OPEN button for every second the                    SELECTOR DIAL
                 operator should wait before attempting to close the door. Press
                 and release the CLOSE button for every 15 seconds the                               T     TS                   Operation will                    T    TS
                 operator should wait before closing the door.                                  E2
                                                                                                                FSTS           vary depending
                                                                                                                                                           E2
                                                                                                                                                                            FSTS
                                                                                                                                on wiring type
                                                                                          D1                      DIAG                               D1                      DIAG

                                                                                          C2                      OPTN                               C2                      OPTN

                                                                                           B2                   PROG                                  B2                    PROG




              Programming                                                          32


TIMER-TO-CLOSE
PROGRAM TIMER-TO-CLOSE BY EXAMPLE (METHOD 2):
TO PROGRAM:
1. Close the door.
2. Turn the selector dial to PROGRAM.                                                                  SELECTOR DIAL
3. Press and hold TIMER button for 5 seconds until OPEN and
   OLS flashes then release.                                                                                      T   TS
                                                                                                             E2
4. Press and release the OPEN button and wait for the door to                                                              FSTS

   reach full open or mid stop position.                                                               D1                   DIAG

5. Wait for desired amount of time to pass. (An internal stop                                          C2                   OPTN
   watch starts counting when the door stops moving.)                                                   B2                 PROG
6. Press and release the TIMER button, CLOSE button or STOP
   button to stop the timer. (TIMER SET LED will turn on.)
7. Turn the selector dial to the desired wiring type (T, TS, FSTS).
                                                                                                                  T
NOTE: To read back the Timer-To-Close setting, turn the selector            Operation will vary              E2
                                                                                                                      TS

dial to DIAGNOSTIC and press the TIMER button. The OPEN LED                 depending on wiring type                       FSTS
                                                                                                       D1
will flash once for every second programmed and the CLOSE LED                                                               DIAG

will flash once for every 15 seconds programmed.                                                       C2                   OPTN
In T Mode, timer can be deactivated from the open position by                                           B2                 PROG
pressing the STOP button. The timer will be reactivated on the
next operation command. The STOP button WILL NOT deactivate
the timer in the TS mode. To deactivate the timer for more than
one cycle in T mode or in TS mode, attach a defeat switch to 11
and 12 (COMMON and TIMER DEFEAT).




CAR DEALER MODE
Feature: The car dealer mode uses the SBC (Single Button Control
input) to bring the door from a closed position to the programmed
Open Mid-Stop position and keep it at that location even with
multiple inputs.
Benefit: Provides energy cost savings by limiting the door                                             SELECTOR DIAL
opening height.
Requirements: This feature works in conjunction with the                                                          T   TS
programmable Timer-To-Close feature. To enable this feature you                                              E2
                                                                                                                           FSTS
must first connect a treadle, photoelectric sensor or loop detector
                                                                                                       D1                   DIAG
accessory to the SBC input and must have at least one LiftMaster
Monitored Entrapment Protection (LMEP) device installed (refer to                                      C2                   OPTN

page 20). Wiring type must be set to TS or T.                                                          B2                  PROG
TO PROGRAM:
1. Start with the door in the closed position.


                                                                                                                                                 PROGRAMMING
                                                                           Operation will vary
2. Turn the SELECTOR DIAL to PROG.                                         depending on wiring type
                                                                                                                  T   TS
3. Push the TIMER button and release (Green Timer LED will                                                   E2
                                                                                                                           FSTS
    be lit).                                                                                           D1                   DIAG
4. Push the MID button and release. This turns on the Car Dealer                                                            OPTN
                                                                                                       C2
    Mode. (The GREEN TIMER LED will flash 6 times indicating the
                                                                                                       B2                  PROG
    Car Dealer Mode is turned on.)
5. Push the TIMER button and release.
6. Turn the SELECTOR DIAL to the desired wiring type (TS or T).
NOTE: To disable the Dealer Mode follow steps 2 and 3, then
press the MRT button and release. (The GREEN TIMER LED will
flash 3 times indicating that the Car Dealer Mode is off.)




                                                                      33                                                           Programming


              MAXIMUM RUN TIMER (MRT)
              Feature: The operator can learn the time it takes to open or close
              the door plus and an additional 10 seconds.                                                         SELECTOR DIAL
              Benefit: If the operator does not meet its open or close limit within
              the set time it will stop, limiting damage to the door and operator.                                    E2
                                                                                                                            T   TS

              To Program:                                                                                                            FSTS
                                                                                                                 D1
              NOTE: The default setting for the MRT is 90 seconds. In the event                                                       DIAG

              the application requires the MRT be manually learned for a longer                                  C2                   OPTN
              duration follow steps below.                                                                       B2                  PROG
              1. Start with the door in the closed position.
              2. Set the selector dial to PROGRAM.
              3. Press and release the MRT button on logic board.
                                                                                           Operation will vary              T   TS
              4. Press the OPEN button and wait for the door to reach the full             depending on wiring         E2
                                                                                                                                     FSTS
                 open limit.                                                               type
                                                                                                                 D1                   DIAG
              5. Once the door has reached the open position, programming is
                                                                                                                                      OPTN
                 complete.                                                                                       C2

              6. Turn dial to desired wiring type.                                                                B2                 PROG

              NOTE: To reset MRT only, turn selector dial to program and press
              and hold the MRT button until the MAS led flashes rapidly.


              RESETTING FACTORY DEFAULTS -
              CLEARING MEMORY
              To reset most of the user installed settings back to factory defaults:
                                                                                                                  SELECTOR DIAL
              1. Turn the selector dial to DIAGNOSTIC.
              2. Press and hold the STOP button for 5 seconds. The MAS LED
                                                                                                                            T
                 will flash momentarily when the factory defaults have been                                           E2
                                                                                                                                TS
                                                                                                                                     FSTS
                 restored.
                                                                                                                 D1                   DIAG
              3. Return the selector dial to the desired wiring type.
              Factory Defaults:                                                                                  C2                   OPTN

              a. Timer-To-Close = 0 seconds.                                                                     B2                  PROG

              b. The Mid Stop is deactivated.
              c. The Maintenance Alert System is deactivated.
              d. The Maximum Run Timer is set to 90 seconds.                                                                T   TS
                                                                                           Operation will vary         E2
              e. Car Dealer Mode is deactivated.                                           depending on wiring                       FSTS

              f. The remote controls and MyQ® devices will still be learned.               type                  D1                   DIAG

              g. Remote control programming via the 3-button station.                                            C2                   OPTN
              h. The LiftMaster Monitored Entrapment Protection (LMEP) device                                     B2                 PROG
                 will be unprogrammed.
              NOTE: Life of Operator feature (Odometer/Cycle Counter) and
              programmed remote controls and MyQ devices are not cleared.
PROGRAMMING




              Programming                                                             34


          WARNING
MAINTENANCE                                                                                     WARNING
MAINTENANCE SCHEDULE
      CAUTION
For use with Maintenance Alert System.                                                            WARNING
Check at the intervals listed in the following chart:                    To avoid SERIOUS personal INJURY or DEATH:
                                                                         • Disconnect electric power BEFORE performing ANY
                                                                           adjustments or maintenance.
                                                                         • ALL maintenance MUST be performed by a trained door
                                                                           systems technician.

                                                                                             EVERY 3      EVERY 6       EVERY 12
                                                                                           MONTHS OR    MONTHS OR     MONTHS OR
             ITEM                            PROCEDURE                   EVERY MONTH      5,000 CYCLES 10,000 CYCLES 20,000 CYCLES

 Drive Chain                       Check for excessive slack.
                                   Check and adjust as required.                               z6
                                   Lubricate.
AVERTISSEMENT
Sprockets  Check set screw tightness.
                                                                                        AVERTISSEMENT
                                                                                          z                                      
 Clutch                            Check and adjust as required.                                                z                
   ATTENTION
 Belt                              Check condition and tension.                           AVERTISSEMENT
                                                                                                  z    
 Fasteners                         Check and tighten as required.                                               z                
 Manual Disconnect                 Check and operate.                                                           z                
 Bearings and Shafts               Check for wear and lubricate.                               z6
 LiftMaster Monitored              Check alignment and
 Entrapment Protection             functionality.                             z
 (LMEP)

6 Use SAE 30 Oil (Never use grease or silicone spray).                        HOW TO ORDER REPAIR PARTS
  • Do not lubricate motor. Motor bearings are rated for                    OUR LARGE SERVICE ORGANIZATION SPANS AMERICA
    continuous operation.
  • Do not lubricate clutch or V-belt.                                          Installation and service information are available.
 Repeat ALL procedures.                                                                   Call our TOLL FREE number:
z Inspect and service whenever a malfunction is observed or                                     1-800-528-2806
  suspected.
                                                                                               www.liftmaster.com

  ADVERTENCIA
LIFE                                      ADVERTENCIA
     OF OPERATOR FEATURE (ODOMETER/CYCLE COUNTER)
The operator is equipped with an odometer to show how many months and cycles the operator has performed from the time it as
installed. This feature can help determine how long the operator has been in service.
 PRECAUCIÓN
1. Start with the door in the closed position.                                               ADVERTENCIA
2. Turn the SELECTOR DIAL to DIAG (diagnostic mode).
3. Press and release the MAS button on the logic board.
4. Press and release the MRT button on the logic board.


                                                                                                                                             MAINTENANCE
5. The open and close lights will flash. OPEN for every 5,000 cycles and CLOSE for every 3 months.
6. Return the SELECTOR DIAL to the desired wiring type.
NOTE: If the operator has not reached 5,000 cycles or 3 months, there will be no indications.

BRAKE (IF PRESENT)
A solenoid brake is available as an option for some models. The
brake is adjusted at the factory and should not need additional
adjustment for the life of the brake assembly.
Inspect the brake pad and replace brake assembly when
necessary.
NOTE: Your operator may look different than the operator shown.




                                                                    35                                                         Maintenance


                  TROUBLESHOOTING
                  DIAGNOSTIC CHART
                  The logic board has several LEDs to assist in the installation and troubleshooting of the operator. The following chart should assist in
                  verifying the operator is functioning properly. Turn the selector dial to DIAGNOSTIC to keep the door from moving while
                  troubleshooting.


                    LED               COLOR             DEFINITION
                    Power             Green             Indicates that power is being generated for the logic board.

                    Stop              Green             Indicates a closed circuit between common and terminal 5. Pressing stop should turn off this LED.

                    Open              Yellow            Indicates a closed circuit between common and terminal 7. Pressing the open button should turn
                                                        ON this LED.

                    Close             Yellow            Indicates a closed circuit between common and terminal 6. Pressing the close button should turn
                                                        ON this LED.

                    LMEP              Green             Solid on indicates LMEP learned. Flashing indicates sensors need to be re-connected or activated, or
                                                        unlearned if removed**. Solid off indicates no sensors learned.

                    Timer Defeat      Yellow            Solid on indicates a closed circuit between common and terminal 12. Timer-To-Close will not close.

                    OLS               Yellow            Pressing the Open Limit Switch should turn ON this LED. Indicates the Open Limit Switch is activated.

                    CLS               Yellow            Pressing the Close Limit Switch should turn ON this LED. Indicates the Close Limit Switch is activated.

                    SLS               Yellow            Pressing the Sensing Limit Switch should turn ON this LED. Indicates the Sensing Limit Switch is activated.

                    Edge              Yellow            Indicates a closed circuit between common and terminal 8. Pressing the edge should turn ON this LED.

                    Mid Stop          Yellow            Solid on indicates door is stopped on up or down mid stop. Flashing indicates MID STOP is being set.

                    Timer Enabled     Green             Solid on indicates TIMER is programmed and will activate from open or mid stop position. Flashing
                                                        indicates Timer is counting down and door will close after preset time. Each flash represents 1 second of
                                                        programmed time.

                    SBC               Yellow            Indicates a closed circuit between common and terminal 1. Pressing the single button control station
                                                        should turn ON this LED.

                    MAS               Yellow            Indicates the Maintenance Alert System has been activated or an error code has been triggered.

                    Relay A           Yellow            Indicates open or close command has been given to the motor. LED turns on when OPEN/CLOSE button is
                                                        pressed.

                    Relay B           Yellow            Indicates open or close command has been given to the motor. LED turns on when OPEN/CLOSE button is
                                                        pressed.

                    DATA              Green             Indicates communication between the Logic 5 board and optional TLS1CARD.




                  ** RESTRICTED CLOSE. This method will allow you to close the door when LMEP device(s) are no longer working. Press and hold the
TROUBLESHOOTING




                     CLOSE button until the door reaches the closed limit. If the CLOSE button is released before the door reaches the closed limit the
                     operator will stop and the procedure will need to be repeated to fully close the door.




                  Troubleshooting                                                        36


TROUBLESHOOTING GUIDE

FAULT                         POSSIBLE CAUSE                                FIX
THE OPERATOR WILL           a) No power supply                         ➤ Verify primary line voltage from power source. Green POWER LED
NOT RESPOND TO ANY                                                       must be on.
COMMANDS                    b) Operator control station is wired wrong ➤ Use the OPEN, CLOSE and STOP LEDs to help check correct wiring.
                                                                         Verify that the board is accepting commands by using the onboard
                                                                         station. Green LED next to stop button must be on.
                            c) Interlock switch is activated           ➤ Check Interlock(s). If more than one external interlock is present they
                                                                         must be wired in series. Green LED next to stop button must be on.
                            d) Dial still in programming, option,      ➤ Set dial to desired wiring type.
                               or diagnostic mode
                            e) Motor is malfunctioning                 ➤ Verify proper voltage getting to the motor (Check motor name plate).
                            f) Motor thermal overload tripped          ➤ Check to see if motor is hot. Allow motor to cool before attempting to
                                                                         move door. Cycle operator in constant pressure one full cycle open and
                                                                         close to reset fault.
                            g) Possible accessory malfunction          ➤ Disconnect all devices, reattach them one at a time testing for a failure
                                                                         after each one is replaced.
                            h) Power Board may need to                 ➤ When the OPEN or CLOSE button is pressed, Relay A or B LED should
                               be replaced                               turn on and the door should move in the corresponding direction. If
                                                                         Relay A or B lights and the door does not move, the Power Board may
                                                                         need to be replaced.
                            i) Possible logic board failure            ➤ Replace logic board.



POWER LED IS NOT ON        a) Loose secondary wiring connections       ➤ Repair or replace connections or control transformer.
                              or a faulty control transformer
                           b) Hoist interlock switch                   ➤ Check interlock. Verify the manual release chain is not engaged.


STOP BUTTON LED IS         a) Control station not connected or wired   ➤ Check wiring to control station.
NOT ON                        correctly
                           b) Interlock switch                         ➤ Check interlock switch(es) for continuity.

THE DOOR WILL MOVE         a) RPM sensor is not connected properly     ➤ Check the RPM assembly for loose connections. Check that RPM wheel
ABOUT A FOOT THEN             or may need to be replaced                 is turning when operator is running. Check for foreign matter blocking
STOP. AFTER STOPPING,                                                    optical lens.
ONLY CONSTANT                                                          ➤ Replace RPM sensor.
PRESSURE COMMANDS          b) Clutch slipping                          ➤ Adjust clutch and verify that door is not binding.
WILL MOVE THE DOOR

THE DOOR WILL MOVE     The Maximum Run Timer is not set                ➤ Manually reprogram the Maximum Run Timer (page 34).
MOST OF THE WAY        correctly                                            OR reset the factory defaults (page 34).
TOWARDS A LIMIT THEN
STOP. AN EXTRA OPEN OR
CLOSE COMMAND IS ABLE
TO GET DOOR TO
COMPLETE CYCLE

THE DOOR WILL OPEN      There may be a Mid Stop set                    ➤ Check to see if the Mid Stop LED is on. Clear the Mid Stop by turning
SOME BUT NOT                                                                the selector dial to program. Press and hold the MID STOP button for
COMPLETELY. AN EXTRA                                                        5 seconds. Return dial to desired wiring type.
OPEN IS ABLE TO GET THE                                                     To reset Open Mid Stop refer to page 32.
DOOR TO OPEN
COMPLETELY
                                                                                                                                                     TROUBLESHOOTING
THE DOOR WILL OPEN BUT a) The LMEP attached is obstructed              ➤ If the on board LMEP LED is flashing, the photoelectric sensor are
WILL ONLY CLOSE AFTER     or activated                                      misaligned or not connected. Remove any obstructions, check the
A FIVE SECOND DELAY                                                         entrapment protection device wires for continuity and shorts.
WITH CONSTANT                                                               If more than one LMEP is installed with the use of a CPS3CARD the
PRESSURE ON THE CLOSE                                                       LMEP will not flash when one of the LMEP’s is blocked.
BUTTON (RESTRICTED
CLOSE MODE)            b) The logic board thinks that the direct       ➤ Unlearn the photoelectric sensors from the memory by resetting
                          connect photoelectric sensors are                 factory defaults.
                          attached and blocked




                                                                       37                                                        Troubleshooting


                  TROUBLESHOOTING ERROR CODES
                  Logic 5.0 operators incorporate a self diagnostic feature built into        by a pause, an operator error has occurred. To view how many
                  the MAS LED. In addition to indicating when routine maintenance             errors currently exist, turn the selector dial to DIAGNOSTIC and
                  is due, the MAS LED can be used to troubleshoot some problems               press the OPEN button. To read out each individual error code
                  with the operator.                                                          (if more than one exists) press CLOSE. It is possible to have more
                  If the MAS LED is flashing on and off rapidly, the Maintenance              than one error at a time.
                  Alert System has been triggered and the schedule operator service           The chart below can assist with identifying the flashes on the
                  is due. If the MAS LED flashes 2 or more pulses in a row followed           MAS LED.



                   ERROR CODE            DISPLAY                  DESCRIPTION                                EFFECT                           CORRECTION
                          E1               1 blink        MAS triggered (cycles or months)        None normal operation              Reset MAS (page 31).
                          E2              2 blinks        No RPM input during opening             The door only responds to          Clutch is slipping, adjust clutch, or
                                                                                                  constant pressure commands         verify RPM sensor connection or
                                                                                                                                     replace RPM sensor.
                                                                                                                                     NOTE: To relearn the RPM sensor,
                                                                                                                                     move the door with a constant
                                                                                                                                     pressure command. The door will
                                                                                                                                     stop once relearned and normal
                                                                                                                                     operation will resume.
                          E3              3 blinks        (MRT) Maximum Run Time timed            The door stops before reaching     First check Operator for any faults
                                                          out                                     set open or close limit(s)         (i.e., Bad Limit switch), manually
                                                                                                                                     learn Max Run Timer (page 34) OR
                                                                                                                                     reset factory defaults (page 34).
                          E4              4 blinks        Obstruction sensed or lost RPM          Operator will reverse to OPEN      Remove obstructions, check
                                                          sensor input on closing                 position                           sensing devices, possible clutch
                                                                                                                                     slippage.
                          E5              5 blinks        Stuck button pressed for greater        Stuck button on 3-button station   Stuck button must be unstuck
                                                          than 2 minutes                          will not respond                   before it will be recognized as an
                                                                                                                                     input.
                          E6              6 blinks        Invalid option card plugged into        Option card will not function      Refer to accessories page for list
                                                          option card receptacles                 properly                           of supported option card(s).
                          E7              7 blinks        LiftMaster Monitored Entrapment         Normal operation (5 second         Cleared when entrapment
                                                          Protection (LMEP) device faulted        constant pressure override         protection device is cleared or
                                                          or removed for greater than             required to close)                 connected.
                                                          2 minutes
                          E8              8 blinks        Brownout Detected                       Operator will run as long as       1. Check AC line for voltage.
                                                                                                  enough power is present            2. Check transformer secondary
                                                                                                                                        for low voltage. Too many
                                                                                                                                        accessories may be connected
                                                                                                                                        to the transformer.
                          E9          Flash on start of   Motor movement at invalid time          Operator will continue to          Check relays and the drive circuitry
                                         movement                                                 function normally for 5            to ensure that they are turning off.
                                                                                                  operations and then default to a   Operator must know that they are
                                                                                                  constant pressure mode             turning off. Operator must run
                                                                                                                                     correctly for two starts for the
                                                                                                                                     error to be cleared.
TROUBLESHOOTING




                         E10              10 blinks       Motor Phase Jumper changed              The phase will not change          Enter programming mode and
                                                          while unit is not in programming                                           move phase jumper to change
                                                          mode                                                                       phase.




                  NOTE: Error codes take priority over normal MAS LED operation. Error codes will repeat on the MAS every 1.5 seconds until cleared.
                  There may be more than one error present, but only the highest priority will flash. If the highest error is cleared, the next highest will
                  flash. All errors self-correct when the corrective action is taken and a reset is not needed.




                  Troubleshooting                                                            38


TROUBLESHOOTING RADIO FUNCTIONALITY
The error codes will display at the radio LED.
NOTE: Radio receiver is compatible with SECURITY+ 2.0 remotes
and touch code devices.

 ERROR CODE          DISPLAY                  SYMPTOM                        POSSIBLE PROBLEM                         CORRECTION
       R1            Quick Flash     No response from the remote.         Unlearned remote -                  Try re-learning the remote
                                                                          A user tries to use a remote, but   (page 29).
                                                                          the RADIO LED only flashes
                                                                          briefly and there is no response
                                                                          from the operator.
       R2          No LED activity   No response from the remote.         Cannot recognize remote -           Replace battery - OR -
                                                                          A weak signal caused by a           eliminate interference - OR-
                                                                          discharged battery or outside       obtain a qualified remote - OR-
                                                                          interference with the remote(s)     check antenna connections.
                                                                          - OR - the remote(s) being
                                                                          learned is not compatible with
                                                                          the operator. Antenna not
                                                                          installed or damaged.
       R3          Radio LED turns   The remote cannot be learned.        Cannot recognize remote -           Replace battery - OR -
                     off after 30                                         A weak signal caused by a           eliminate interference - OR-
                      seconds                                             discharged battery or outside       obtain a qualified remote - OR-
                                                                          interference interfering with the   check antenna connections.
                                                                          learn process - OR - the
                                                                          remote(s) being learned is not
                                                                          compatible with the operator.
                                                                          Antenna not installed or
                                                                          damaged.
       R4             2 blinks       The remote cannot be learned.        Receiver memory full -              Erase all learned remotes and
                                                                          A user enters RADIO function        re-learn the desired remote.
                                                                          learning mode but there is no
                                                                          space left to add another remote.
       R5             3 blinks       The remote cannot be learned.        Duplicate remote -                  This remote already has a function
                                                                          A user enters RADIO function        associated with it. To change the
                                                                          learning and selects the function   function, erase all learned remotes
                                                                          to be learned. When the remote      and re-learn the desired remote.
                                                                          button is pressed for learning, a
                                                                          search reveals that remote is
                                                                          already learned.
       R6         LMEP LED flashes Cannot close via constant pres-        No entrapment protection device     Must connect a LiftMaster
                                   sure in C2, D1 or E2 modes.            present -                           Monitored Entrapment Protection
                                                                          A sensing device is required to     (LMEP) device.
                                                                          close via constant pressure.




                                                                                                                                                    TROUBLESHOOTING




                                                                     39                                                        Troubleshooting


                  WIRING DIAGRAMS
                  LOGIC (VER. 5.0) 1 PHASE WIRING DIAGRAM                                                                                                                                                                         Maintenance
                                                                                                                                                                                                                                    Alert LED                                                                             OPEN
                                                                                                                                                                                                                                (RD)        (WH)
                                                                                                                                                                                                                                                                                                                          CLOSE




                                           TBD
                                                                                                                                                                                                                                                  Open

                                                                                                                                                                                                                                                                                                                          STOP
                                                                                                                                                                                                                                                  Close
                                                                                                                                                                          Sensing
                                                                                                                                                                           Edge
                                                                                                                                                                                                                                                                                                                  3-Button Station
                                        Refer to page 21 for                                                                                                                                                                                        Stop
                                        LiftMaster Monitored
                                        Entrapment Protection (LMEP)
                                        device connections                                                                                                                                                                                                       Open/Close
                                                                                                                                                                                                                                                                Single Button
                                                     Hoist Interlock
                                                     When Present                                               TMR DEF
                                                                                                    (BL)        SWITCH
                                                                                                 (YE)                                                                                                                                                                                                                Remove Jumper
                                                                                                                                                                                                                                                                                                                    To Install External




                                                                                                               14

                                                                                                                                   13

                                                                                                                                             12

                                                                                                                                                         11

                                                                                                                                                                          10

                                                                                                                                                                                   9

                                                                                                                                                                                                     8

                                                                                                                                                                                                                7

                                                                                                                                                                                                                            6

                                                                                                                                                                                                                                 5

                                                                                                                                                                                                                                                  4

                                                                                                                                                                                                                                                                 3

                                                                                                                                                                                                                                                                                       2

                                                                                                                                                                                                                                                                                                  1
                                                                DATA




                                                                                    C61

                                                                                                                                                                                                                                                                                                                      Door Interlock
                                                                              C8
                                                                 C1




                                                                                                                                                                                                                                                     COMMON
                                                                                                                                                         COMMON
                                                                                                                                              TIMER
                                                                                                                                             DEFEAT
                                                                                                                           POWER




                                                                                                                                                                                                                                                                                                       SBC
                                                                                                               24VAC



                                                                                                                                    24VAC




                                                                                                                                                                                                EDGE:




                                                                                                                                                                                                                        CLOSE
                                                                                                                                                                                      LMEP:



                                                                                                                                                                                                         OPEN




                                                                                                                                                                                                                                 STOP
                                                                                                                                                                    MAS




                                                                                                                                                                                               ENABLE
                                                                                                                                                                                                TIMER
                                                                                                                                                      3-PHASE

                                                                                                                                                      1-PHASE




                                                                                                                                                                                                                                                                      OPTN
                                                                                                                                                                                                                                                        DIAG



                                                                                                                                                                                                                                                                                PROG
                                                                                                                                                                                                                                             FSTS
                                                                                                                                                                                                                                                                                                                   (YE)




                                                                                                                                                                                               TTC



                                                                                                                                                                                                                3
                                                                                                                                                                                                                                                                                                                   (OR)




                                                                                                                                                                                                                                        TS
                                                                                                                                                                                                                                                                                                                   (WH)




                                                                                                                                                                                                                                                                                                        A
                                                                                                                                                                                                                                                                                                        B
                                                                                                                                                                                                                                                                                                                   (YE)


                                                                                                                                                                                               MID
                                                                                                                                                                                                                                                                                                                   (PU)




                                                                                                                                                                                                                2




                                                                                                                                                                                                                                                                                                        RELAY
                                                                                                                                                                                                                                                                                                        RELAY
                                                                                                                                                                                                                                                                                                                   (WH)




                                                                                                                                                                                                                                        T
                                                                                                                                                                                                                                                                                                                   (RD)
                                                                                                                                                                                                                                                                                                                   (GY)




                                                                                                                                                                                                                                                                                    B2
                                                                                                                                                                                               MRT




                                                                                                                                                                                                                                             E2

                                                                                                                                                                                                                                                      D1
                                                                                                                                                                                                                1




                                                                                                                                                                                                                                                                      C2
                                                                                                                                                                                                                                                                                                                   (YE)
                                                                                                                                                                                                                                                                                                                   (RD)
                                                                                                                                                                                                                                                                                                                   (WH)
                                                                                                                                                                                                                                                                                                                   (PU)
                                                                                                                                                                                                                RADIO
                                                                                                                                                   OLS




                                                                                                                                                                                   CLS
                                                                                                                                                                           SLS
                                                                                                                                                                  MID




                                                                                                                                                                                                                                                                                                                   (YE)
                                                                                                                                                                                                                                                                                                                   (OR)

                                                                                                                                                      REV             MOTOR                                                                                                                                        (BK)
                                                                                                                                                                    DIRECTION                                                                                                                                      (GY)
                                                                                                                                                      STD
                                                                       SLOT   1                       SLOT             2




                                                                          hot
                                                                                    L3 L2 L1




                                                                                                          MOV
                                                                        neutral
                                                                                                           MOV
                                                                        ground
                                                         VOLT 1PH.
                                                         POWER IN
                                                         115 / 230




                                                                          (WH)


                                                                              COM         120         120 / 240
                                                                                          VAC           VAC




                                                                              +24 VAC           -24 VAC
WIRING DIAGRAMS




                                                         (YE)



                                                                                                                (WH)                        (RD)         (PU)
                                                                                                                                                                          (WH)
                       NOTE: Lock Sensor is provided on Models
                       DJ and DH only, red wire from main harness                                          COM
                                                                                                                           NO                                                    NO
                                                                                                                                                                                              COM                                                                                                                      (WH)        (OR)    (YE)
                                                                                                                                                                                                                                                               (WH)
                                                                                                                                                                                                                                                                             (RD)




                                                                                               OPEN L/S                                                                               CLOSE L/S
                                                                                                                                                                                                                                                                                                (GY)
                                                                                                                                                                                                                                                                                         (YE)




                       connects to NC on Bypass L/S and to NO on                                                           NC                                                    NC

                       LOCK SENSOR switch. White wires connect the                                                                                                                                                                                                                                                   R1       R2          R3
                                                                                                                                   (WH)
                       COM on BYPASS L/S and LOCK SENSOR switch
                                                                                                                                                                                                                                                                 1 2 3 4
                       to NC on Open L/S.                                                                                                                                   (YE)

                                                                                                                                                                                                                                                                  RPM Board
                                                                                                                                                                                 NC
                                                                                                                                                                                      SAFETY L/S                                                                                                                External Radio Receiver
                       NOTE: The Lock Sensor switch is                                                                                                                           NO
                                                                                                                                                                                              COM
                                                                                                                                                                   (WH)                                                                                                                                         NOTE: 32 Vdc power supplied
                       located in the chassis.
                                                                                                                                                                                                                                                                                                                from White and Yellow wires located
                                                                                                                                                                          (WH)                COM                                                                                                               within the electrical box.
                                                                                                                                                                                 NO
                                                                                   (WH)           LOCK                              (RD)                  (RD)                                BYPASS
                                                                                                                           NO                                                    NC
                                                                                                 SENSOR                    NC
                                                                                                                                                                                                L/S
                                                                                                (see note at left)



                  Wiring Diagrams                                                                                                                                         40


LOGIC (VER. 5.0) 3 PHASE WIRING DIAGRAM
                                                                                                                                                                                                           Maintenance
                                                                                                                                                                                                             Alert LED                                                                             OPEN
                                                                                                                                                                                                         (RD)        (WH)



                            TBD                                                                                                                                                                                            Open


                                                                                                                                                                                                                           Close
                                                                                                                                                                                                                                                                                                   CLOSE



                                                                                                                                                                                                                                                                                                   STOP

                                                                                                                                                  Sensing
                                                                                                                                                   Edge
                                                                                                                                                                                                                                                                                           3-Button Station
                   Refer to page 21 for                                                                                                                                                                                      Stop
                   LiftMaster Monitored
                   Entrapment Protection (LMEP)
                   device connections                                                                                                                                                                                                     Open/Close
                                                                                                                                                                                                                                         Single Button
                                Hoist Interlock
                                When Present                                              TMR DEF
                                                                              (BL)        SWITCH
                                                                           (YE)                                                                                                                                                                                                               Remove Jumper
                                                                                                                                                                                                                                                                                             To Install External



                                                                                         14

                                                                                                             13

                                                                                                                      12

                                                                                                                                 11

                                                                                                                                                  10

                                                                                                                                                           9

                                                                                                                                                                              8

                                                                                                                                                                                         7

                                                                                                                                                                                                     6

                                                                                                                                                                                                          5

                                                                                                                                                                                                                           4

                                                                                                                                                                                                                                          3

                                                                                                                                                                                                                                                                2

                                                                                                                                                                                                                                                                           1
                                           DATA




                                                               C61



                                                                                                                                                                                                                                                                                               Door Interlock
                                                         C8
                                            C1




                                                                                                                                                                                                                              COMMON
                                                                                                                                 COMMON
                                                                                                                       TIMER
                                                                                                                      DEFEAT
                                                                                                     POWER




                                                                                                                                                                                                                                                                                SBC
                                                                                         24VAC



                                                                                                              24VAC




                                                                                                                                                                         EDGE:




                                                                                                                                                                                                 CLOSE
                                                                                                                                                               LMEP:



                                                                                                                                                                                  OPEN




                                                                                                                                                                                                          STOP
                                                                                                                                            MAS




                                                                                                                                                                        ENABLE
                                                                                                                                                                         TIMER
                                                                                                                               3-PHASE

                                                                                                                               1-PHASE




                                                                                                                                                                                                                                               OPTN
                                                                                                                                                                                                                                 DIAG



                                                                                                                                                                                                                                                         PROG
                                                                                                                                                                                                                      FSTS
                                                                                                                                                                                                                                                                                            (YE)




                                                                                                                                                                        TTC



                                                                                                                                                                                         3
                                                                                                                                                                                                                                                                                            (OR)




                                                                                                                                                                                                                 TS
                                                                                                                                                                                                                                                                                            (WH)




                                                                                                                                                                                                                                                                                 A
                                                                                                                                                                                                                                                                                 B
                                                                                                                                                                                                                                                                                            (YE)

                                                                                                                                                                        MID
                                                                                                                                                                                                                                                                                            (PU)




                                                                                                                                                                                         2




                                                                                                                                                                                                                                                                                 RELAY
                                                                                                                                                                                                                                                                                 RELAY
                                                                                                                                                                                                                                                                                            (WH)




                                                                                                                                                                                                                 T
                                                                                                                                                                                                                                                                                            (RD)
                                                                                                                                                                                                                                                                                            (GY)




                                                                                                                                                                                                                                                             B2
                                                                                                                                                                        MRT




                                                                                                                                                                                                                      E2

                                                                                                                                                                                                                               D1
                                                                                                                                                                                         1




                                                                                                                                                                                                                                               C2
                                                                                                                                                                                                                                                                                            (YE)
                                                                                                                                                                                                                                                                                            (RD)
                                                                                                                                                                                                                                                                                            (WH)
                                                                                                                                                                                                                                                                                            (PU)
                                                                                                                                                                                         RADIO
                                                                                                                           OLS




                                                                                                                                                           CLS
                                                                                                                                                   SLS
                                                                                                                                          MID




                                                                                                                                                                                                                                                                                            (YE)
                                                                                                                                                                                                                                                                                            (OR)

                                                                                                                               REV            MOTOR                                                                                                                                         (BK)
                                                                                                                                            DIRECTION                                                                                                                                       (GY)
                                                                                                                               STD
                                                  SLOT   1                      SLOT             2
                                                               L3 L2 L1




                                                                                    MOV


                                                                                     MOV
                                     208/230/460
                                     VOLT 3PH.
                                     POWER IN




                                                  (WH)


                                                     COM      120          120 / 240
                                                              VAC            VAC




                                                    +24 VAC           -24 VAC

                                    (YE)                                                                                                                                                                                                                                                                                                  WIRING DIAGRAMS

                                                                                          (WH)                    (RD)         (PU)
                                                                                                                                                  (WH)
  NOTE: Lock Sensor is provided on Models
  DJ and DH only, red wire from main harness                                         COM
                                                                                                     NO                                                   NO
                                                                                                                                                                       COM                                                                                                                      (WH)        (OR)    (YE)
                                                                                                                                                                                                                                        (WH)
                                                                                                                                                                                                                                                      (RD)




                                                                          OPEN L/S                                                                             CLOSE L/S
                                                                                                                                                                                                                                                                         (GY)
                                                                                                                                                                                                                                                                  (YE)




  connects to NC on Bypass L/S and to NO on                                                          NC                                                   NC

  LOCK SENSOR switch. White wires connect the                                                                                                                                                                                                                                                 R1       R2          R3

  COM on BYPASS L/S and LOCK SENSOR switch                                                                   (WH)
                                                                                                                                                                                                                                          1 2 3 4
  to NC on Open L/S.                                                                                                                                (YE)

                                                                                                                                                                                                                                           RPM Board
                                                                                                                                                          NC
                                                                                                                                                               SAFETY L/S                                                                                                                External Radio Receiver
  NOTE: The Lock Sensor switch is                                                                                                                         NO
                                                                                                                                                                       COM
                                                                                                                                           (WH)                                                                                                                                          NOTE: 32 Vdc power supplied
  located in the chassis.
                                                                                                                                                                                                                                                                                         from White and Yellow wires located
                                                                                                                                                  (WH)                 COM                                                                                                               within the electrical box.
                                                                                                                                                          NO
                                                              (WH)          LOCK                              (RD)               (RD)                                  BYPASS
                                                                                                     NO                                                   NC
                                                                           SENSOR                    NC
                                                                                                                                                                         L/S
                                                                          (see note at left)



                                                                                                                                                         41                                                                                                                                                             Wiring Diagrams


                                                                                                                                                               OPEN
                                                                        OPEN




              ACCESSORIES                                                                                                          ENTRAPMENT PROTECTION DEVICES
              REMOTE CONTROLS 315MHz                                                                                                                                              MONITORED
                                                         LiftMaster offers a variety of SECURITY✚® Remote Controls for your            CPS-UN4                        Commercial Protector System®:
                                                         application needs. Single to 4-Button, visor or key chain. Contact
                                                                                                                                                                      Provides protection on doors up to 45' wide. NEMA-4 rated.
                                                         your authorized dealer.
              371LM                                      1-Button SECURITY✚® Remote Control:
                                                         Includes visor clip.                                                          CPS-U                          Commercial Protector System®:
                                                                                                                                                                      Provides protection on doors up to 30' wide.
              373LM                                      3-Button SECURITY✚® Remote Control:
                                                         Includes visor clip.
                                                                                                                                       CPS3CARD                       Option Logic Board:
              333LM                                      3-Button Tri-Colored Dip Switch Remote Control:
                                                                                                                                                                      For use when more than one set of photoelectric sensors are
                                                         Includes visor clip.
                                                                                                                                                                      required. Also available pre-packaged with a second set of
              WPB1LM3                                    Wireless Single Push Button Control SECURITY✚®:                                                              photoelectric sensors; see CPS3 or CPS3-N4 in Commercial Door
                                                         Rugged composite housing. (Wireless controls cannot be                                                       Operator Product and Accessories Price List for more information.
                                                         used in place of hard wired controls.)                                        CPS-EI                         Monitored Sensing Edge Interface:
                                                  OPEN



                                                                                                                                                                      For use with the approved 4-wire edge (see below).
              WPB3LM3                                    Wireless 3 Button Control Station SECURITY✚®:                                   40-34141-1




                                                         Rugged composite housing. (Wireless controls cannot be used in            65ME1234                           Miller ME123 4-Wire Sensing Edge:
                                                         place of hard wired controls.)
                                                                                                                                                                      For sectional or rolling doors.
                                                                                                                                   65ME110                            Miller ME110 4-Wire Sensing Edge:
              WKP5LM3 (5 4-digit entry codes)                                                                                                                         For rolling grilles and counter shutters.
              WKP250LM3 (250 4-digit entry codes)
                                                         Wireless Access Control Keypads SECURITY✚®:                                   MOUNTING CHANNELS
                                                                                                                                   65ME123C
                              1       2       3

                          7
                              4
                                  8
                                      5
                                          9
                                              6
                                                         Rugged composite housing. (Wireless controls cannot be                                                       U-Shaped Mounting Channel:
                         *        0

                                                         used in place of hard wired controls.)
                                          #

                                                                                                                                                                      For 65ME1234 edge when installed on sectional doors.
              CONTROL STATIONS                                                                                                     65ME123C1            OPEN          T-Shaped Mounting Channel:
              02-101                                     1-Button Control Station:                                                               OPEN

                                                                                                                                                                      For 65ME1234 edge when installed on rolling doors. Fits between
                                                         Steel enclosure.                                                                                             L-shaped angles used to construct a bottom bar on rolling doors.
                         OPEN


                                                                                                                                   65ME123CA3                         L-Shaped Mounting Channel:
                                                                                                                                                                      For 65ME1234 edge when installed on sectional doors.
              02-102                                     2-Button Control Station:
                                                         Steel enclosure.                                                                                                      NON-MONITORED
                                                                                                                                       65-8202                        Vehicle Detection System:
                                                                                                                                                                      Pneumatic Sensing Edge Kit with exterior air switch, 2-wire
              02-103L                                    3-Button Control Station:                                                                                    coil cord and 14' air hose.
                                                         Steel enclosure with Maintenance Alert System.                                65-5202                        Vehicle Detection System:
                                                                                                                                                                      Pneumatic Sensing Edge Kit with exterior air switch, 2-wire
                                                                                                                                                                      take-up reel (20' extended) and 14' air hose.
              02-110                                     Key Control Station:
                OPEN      CLOSE
                                                         Indoor flush mount, NEMA 1 with Stop button.                                  OPTION CARDS
                       STOP
                                                                                                                                       TLS1CARD                       Timer Light Status Card:
                                                                                                                                                                      The TLS option card provides special functionality to
                                                                                                                                                                      activate and flash auxiliary devices such as lights, bells, and
              MOUNTING BRACKETS                                                                                                                                       horns/strobes at various door positions, and to provide
              10-12360                                   Heavy gauge steel bracket for vertical or horizontal mount on either                                         special timer functions.
                                                         front or top of coil on a rolling door. Has a variety of mounting hole
                                                                                                                                   AUXCARD                     Auxiliary Contact Card:
                                                         patterns compatible with many OEM manufacturers. For use with J,
                                                         H, DJ, and DH operators. May be welded.                                                               The Auxiliary Contact option card has both Normally-Open
                                                                                                                                                               and Normally-Closed contacts that actuate when the door is
              08-9098                                    Cast iron bracket to mount J, H, DH, DJ, and GH side mount                                            idle, opening, or closing.
                                                         operators on end bracket of a rolling door or grill. For vertical or          CHAIN            TENSIONERS                              For Jackshaft Type Operators
                                                         horizontal mount on either front or top of coil. Cannot be welded.            71-6023                        For 1" shafts. Recommended to properly tension drive chain
                                                                                                                                                                      between operator shaft and door shaft.
                                                                                                                                                                      Same as 71-6023, but for 1-1/4" shafts.
ACCESSORIES




              08-9098EZ                                  Same as 08-9098, but with adapter plate to hold mounting bolts in             71-6125
                                                         place for easy mounting.
                                                                                                                                       MISCELLANEOUS
                                                                                                                                   1A3982                             Operator Cover:
              1A4324                                     Heavy gauge steel bracket for vertical or horizontal mount on either                                         For use with wall-mounted J, H, GH, DH or DJ operators.
                                                         front or top of coil on a rolling door. May be welded. For use with J,                                       Measures 31" x 19" x 18" (L x W x D). Assembly required.
                                                         H, DJ, and DH operators.                                                                                     Recommended for damp environments where direct spray is
                                                                                                                                                                      present. Required when the operator is installed less than 8
                                                         Same as 1A4324, but with adapter plate to hold mounting bolts in          86LM (15')                         feet above the floor.
              1A4324EZ
                                                         place for easy mounting.                                                  86LMT (25')
                                                                                                                                                                      Antenna Extension Kit:
                                                                                                                                                                      The antenna extension kit can be used with EXT-ANT for
                                                                                                                                                                      maximum radio receiver range.
              Accessories                                                                                                         42


    CONTROL CONNECTION DIAGRAM
       IMPORTANT NOTES:
       1. The 3-Button Control Station provided must be connected for operation.
       2. If a STOP button is not used, a jumper must be placed between terminals 4 and 5.
       3. When adding accessories, install them one at a time and test each one after it is added to ensure proper installation and operation
          with the Commercial Door Operator.

                  3 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER AND STOP BUTTON
                      STANDARD                                               2 OR MORE                                          KEY LOCKOUT
                       10       7        6    4       5                 10    7 6 4          5                                     10    7 6           4    5

.
                                                                                                                               (RED)
                (RED)                                             (RED)
                                         Open                                                                                                       Open
                                                                                   Open              Open
        Maintenance                                                                                                   Maintenance
         Alert LED                       Close            Maintenance                                                  Alert LED                    Close
                                                                                   Close             Close
                                                           Alert LED
                                                                                                                                                    Stop
                                         Stop                                                                               (WHITE)
              (WHITE)                                          (WHITE)             Stop                Stop


                                                           NOTE: Stop circuit must be wired in series for
                                                           all stop buttons to function. This may require
                                                           removal of factory installed jumper bar in the
                                                           3-button station.                                                                    Keyswitch

                                2 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER
                                         STANDARD                                                                      2 OR MORE
                      7     6        4                                                           7    6      4

                                                            D1 & E2                                                                          D1 & E2
                                                           MODE ONLY                                                                        MODE ONLY
                            Open                                                                       Open                  Open

                                                             See note 2.                                                                     See note 2.
                            Close                                                                      Close                 Close
        TIMER DEFEAT SWITCH                       1 BUTTON STATION OR ANY AUXILIARY DEVICE                                  RADIO CONTROLS


                11 12                                     OPEN / CLOSE                                            (WH) (OR) (YE)
                                                             1 4
                                                                             B2, T, TS & FSTS                    R1    R2     R3           EXTERNAL
                                                                               MODE ONLY                                                   RADIO RECEIVER

               Keyswitch                                                                                     NOTE: 32 Vdc power supplied from white
                                                                               See note 2.                   and yellow wires located within the
                                                                                                             electrical box.
          NON-MONITORED EDGE SENSOR TO REVERSE OR STOP                                                     EXTERNAL INTERLOCK
                Note: 11 and 4 are both the same common.                                             Remove Factory Installed Jumper
                           Either is acceptable.                                                        When Interlock is Used
                                         11       8
                                                                                                 2           3                         2        3


                                    Edge Sensor
                                                                                                     ONE                               2 OR MORE
                                                                                                                 All Wiring Types



                                                                                    43                                                      Control Connection Diagram


           © 2013, The Chamberlain Group, Inc.
01-36811           All Rights Reserved



Document Created: 2014-02-17 16:37:02