Test Report Part 4

FCC ID: H8NWLL4030

Test Report

Download: PDF
FCCID_498375

FCC ID: H8NWLL4030


5.4.3 TEST PROCEDURE
 1.    The transmitter output was connected to the spectrum analyzer.
 2.    Set the spectrum bandwidth span to view the entire spectrum.
 3.    Using peak detector and Max-hold function for Trace 1 (RB=1MHz, VB=3MHz)
       and 2 (RB=1MHz, VB=300kHz).
 4.    The largest difference between Trace 1 and Trace 2 in any 1MHz band on any
       frequency was recorded.




5.4.4 DEVIATION FROM TEST STANDARD

No deviation




5.4.5 TEST SETUP



                  EUT                            Power Meter




5.4.6 EUT OPERATING CONDITIONS


The software provided by client to enable the EUT under transmission condition
continuously at specific channel frequencies individually.




Report No.: RF920624R02D                 99                         Issued: Dec.10, 2004
Reference No.: RF920624R02


FCC ID: H8NWLL4030


5.4.7       TEST RESULTS


EUT                     Mini- PCI CARD             MODEL         WLL4030

ENVIRONMENTAL           24deg. C, 64%RH,           INPUT POWER
                                                                 120Vac, 60 Hz
CONDITIONS              991hPa                     (SYSTEM)

TESTED BY               Leo Hung


                                                         PEAK to
                    CHANNEL          PEAK POWER
                                                        AVERAGE
 CHANNEL           FREQUENCY          EXCURSION                         PASS/FAIL
                                                     EXCURSION LIMIT
                      (MHz)              (dB)
                                                          (dB)
        1                5180              6.38            13               PASS
        4                5240              6.63            13               PASS
        5                5260              6.62            13               PASS
        8                5320              6.34            13               PASS
        9                5745              6.60            13               PASS
        12               5805              7.36            13               PASS




Report No.: RF920624R02D                     100                        Issued: Dec.10, 2004
Reference No.: RF920624R02


FCC ID: H8NWLL4030


CH 1




Report No.: RF920624R02D     101   Issued: Dec.10, 2004
Reference No.: RF920624R02


FCC ID: H8NWLL4030


CH 4




Report No.: RF920624R02D     102   Issued: Dec.10, 2004
Reference No.: RF920624R02


FCC ID: H8NWLL4030


CH 5




Report No.: RF920624R02D     103   Issued: Dec.10, 2004
Reference No.: RF920624R02


FCC ID: H8NWLL4030


CH 8




Report No.: RF920624R02D     104   Issued: Dec.10, 2004
Reference No.: RF920624R02


FCC ID: H8NWLL4030


CH 9




Report No.: RF920624R02D     105   Issued: Dec.10, 2004
Reference No.: RF920624R02


FCC ID: H8NWLL4030


CH 12




Report No.: RF920624R02D     106   Issued: Dec.10, 2004
Reference No.: RF920624R02


FCC ID: H8NWLL4030




5.5     PEAK POWER SPECTRAL DENSITY MEASUREMENT

5.5.1 LIMITS OF PEAK POWER SPECTRAL DENSITY MEASUREMENT


                 Frequency Band                                 Limit
                  5.15 – 5.25GHz                                4dBm
                 5.25 – 5.35GHz                                11dBm
                5.725 – 5.825GHz                               17dBm




5.5.2 TEST INSTRUMENTS

 Description & Manufacturer            Model No.         Serial No.        Calibrated Until

    SPECTRUM ANALYZER                   FSEK30             100049            Aug. 12, 2005

NOTE: The calibration interval of the above test instruments is 12 months and the calibrations are
traceable to NML/ROC and NIST/USA.




Report No.: RF920624R02D                        107                                Issued: Dec.10, 2004
Reference No.: RF920624R02


FCC ID: H8NWLL4030




5.5.3 TEST PROCEDURES


 1. The transmitter output was connected to the spectrum analyzer.
 2. Set RBW=1MHz, VBW=3MHz. The PPSD is the highest level found across the
    emission in any 1MHz band.



5.5.4 DEVIATION FROM TEST STANDARD

No deviation



5.5.5 TEST SETUP



                  EUT                        SPECTRUM
                                             ANALYZER




5.5.6 EUT OPERATING CONDITIONS
Same as 5.3.6




Report No.: RF920624R02D            108                        Issued: Dec.10, 2004
Reference No.: RF920624R02


FCC ID: H8NWLL4030


5.5.7 TEST RESULTS

  EUT                        Mini- PCI CARD           MODEL         WLL4030

  ENVIRONMENTAL              24deg. C, 64%RH,         INPUT POWER
                                                                    120Vac, 60 Hz
  CONDITIONS                 991hPa                   (SYSTEM)

  TESTED BY                  Ansen Lei


                         CHANNEL           RF POWER      MAXIMUM
     CHANNEL            FREQUENCY        LEVEL IN 1MHz    LIMIT       PASS/FAIL
                          (MHz )           BW (dBm)       (dBm)
           1                 5180             -1.25           4          PASS
           4                 5240             -1.68           4          PASS
           5                 5260             -0.63           11         PASS
           8                 5320             -0.38           11         PASS
           9                 5745             0.76            17         PASS
          12                 5805             0.70            17         PASS




Report No.: RF920624R02D                      109                      Issued: Dec.10, 2004
Reference No.: RF920624R02


FCC ID: H8NWLL4030


CH 1




Report No.: RF920624R02D     110   Issued: Dec.10, 2004
Reference No.: RF920624R02


FCC ID: H8NWLL4030


CH 4




Report No.: RF920624R02D     111   Issued: Dec.10, 2004
Reference No.: RF920624R02


FCC ID: H8NWLL4030


CH 5




Report No.: RF920624R02D     112   Issued: Dec.10, 2004
Reference No.: RF920624R02


FCC ID: H8NWLL4030


CH 8




Report No.: RF920624R02D     113   Issued: Dec.10, 2004
Reference No.: RF920624R02


FCC ID: H8NWLL4030


CH 9




Report No.: RF920624R02D     114   Issued: Dec.10, 2004
Reference No.: RF920624R02


FCC ID: H8NWLL4030


CH 12




Report No.: RF920624R02D     115   Issued: Dec.10, 2004
Reference No.: RF920624R02


FCC ID: H8NWLL4030




5.6     FREQUENCY STABILITY

 5.6.1 LIMITS OF FREQUENCY STABILITY MEASUREMENT

The frequency tolerance of the carrier signal shall be maintained within +/- 0.02% of
the operating frequency over a temperature variation of –30 degrees to 50 degrees
C at normal supply voltage, and for a variation in the primary supply voltage from
85% to 115% of the rated supply voltage at a temperature of 20 degrees C.


5.6.2 TEST INSTRUMENTS


      Description & Manufacturer             Model No.       Serial No.     Calibrated Until

 ANRITSU SPECTRUM ANALYZER                   MS2667C          M10281          Feb. 09, 2005

 WIT STANDARD TEMPERATURE
                                              TH-4S-C        W981030           Jul. 18, 2005
   AND HUMIDITY CHAMBER

NOTE: The calibration interval of the above test instruments is 12 months and the calibrations are
traceable to NML/ROC and NIST/USA.




5.6.3     TEST PROCEDURE

1. The EUT was placed inside the environmental test chamber and powered by
    nominal DC voltage.
2. Turn the EUT on and couple its output to a spectrum analyzer.
3. Turn the EUT off and set the chamber to the highest temperature specified.
4. Allow sufficient time (approximately 30 min) for the temperature of the chamber to
    stabilize, turn the EUT on and measure the operating frequency after 2, 5, and
    10 minutes.
5. Repeat step 2 and 3 with the temperature chamber set to the lowest temperature.
6. The test chamber was allowed to stabilize at +20 degree C for a minimum of 30
    minutes. The supply voltage was then adjusted on the EUT from 85% to 115%
    and the frequency record.




Report No.: RF920624R02D                        116                                Issued: Dec.10, 2004
Reference No.: RF920624R02


FCC ID: H8NWLL4030


5.6.4 DEVIATION FROM TEST STANDARD

No deviation



5.6.5 TEST SETUP

                             Temperature


        Spectrum Analyzer




                       DC Power Supply




5.6.6 EUT OPERATING CONDITION


Same as Item 4.1.6




Report No.: RF920624R02D                   117   Issued: Dec.10, 2004
Reference No.: RF920624R02


Foo ID: HexwLi4030



56.    TEST RESULTS

     Operating frequency: SI20MHz                                  Limit : £0.02%
Temp. ::;vpel;      2minute                         S minute                  10 minute
 CC)     voe)        (MHc)         C           (itte)          C         (itte)        C
           1ss       _|_sezn orae! o corssoe| seroor0el _ocorseod) semaori2l oomesed
  so       120       sez oroel     oomaoogl    sernoreel     oociosoel   sembori2l   ocorced
           102       _|_sezn orae! _o corssoel sez oroel ocorse0d) sezaori2l oomesed
           Tss       _|_soze orez! _o oooreer] soro oazel o conrare) sez0 oceel o ccosood
  «0       120       sem0 ocezl   o ocorsedl   Sean oeral   oooorerol    sez arel    oconso08
           102       _|_saze orzel _o oooreer] soro cazel o conrare) sez0 o«eel o ccosood
           Tss       _|_sozn onezl _o coveseol soro oneal ocomseal sezn ons] o comised
  8        120       semomml      ooceimed     semnomenl    ooomsiol     soroopedl   ocomsea
           102       _|_sezn onezl _o coveseol soro oneal ocomseal sezn ons] o comised
           Tss       _|_sozn orsz! _o ooonssel soro oreal oconzsso! sezn or2] o ccorsed
  20       120       semo or2l    oocorsed     sez orenl    oocomssol    soroaredl   0002050
           102       _|_sezn orez! _o ooonssel soro real oconzsso! sezn or2] o ccorsed
           Tss       _|_seznorso! _oovonseel soro orso! ocoonsee! sezoorsol o cccees
  10       120       sez orsol    o odomsenl   seznorsol    oocorsedl    soroateo)   oconzece
           102       _|_seznorso! _oovonseal soro orso! ocoonsee! sezoorsol o cce
           Tss       _|_seznoose! o ocortee] sorocosel occontes) _sezooces] _occontes
   0       120       semo ooen)    oncories    Seznoosdl    oocorieol    sorooocdl    oocomc
           102       _|_sezn oose! o ocortee] soro cosel occontes) sezooces] _occontes
           1ss       _|_sezn core) o covistel sz coro! _ocomare) _seza core|_occororg
  a0       120       sem0 coral   o o0oranel   Se2ncorel    ooonistel    serocord)   ocomiane
           102       _|_sezn core) o covistel sez coro! _ocomare) seza core|_occororg
           Tss       _|_suzn oone! _o cooteos] soro cone! o comteas) sez0.c00e] o coore09
  20       120       sez odeel    o ooore0nl   5o0 oonel    ooooieoo)    sro conel   ocomteds
           102       _|_sazn oonel _o cooteos] sro cone! o comteas) sez0.c00e] o coore09
           Tss       _|_soze oroe! _o ooozasol soro aroel o co0zaso! sezn oroel o ccozosd
  «        120       sez oroel    o o0oz000l   Se2e ordel   orovopnsol   sroatosl    0002050
           102       _|_saze oroel o ovcznsol soro aroel o co0zoso! sezn oroel o ccoz000
"TTre Test datais in accordance with ADT Report No: RFS200e OR )



ResorN: resessinozo                            ns                                 Isad:Dee,oot
Adtvnrce No: mrssocemnce



Document Created: 2004-12-17 17:38:08
Document Modified: 2004-12-17 17:38:08

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC