RF exposure Info

FCC ID: H8NRTA7105W

RF Exposure Info

Download: PDF
FCCID_707289

                                                                                            Report No. 066L049




          RF Exposure Evaluation declaration


       Product Name                 :    Home Gateway
       Model No.                    :    Askey: RTA7105W
                                         HUAWEI: Echolife HG5205
       FCC ID.                      :    H8N RTA7105W




  Applicant : ASKEY TECHNOLOGY(JIANGSU)LTD.
  Address : No.1388 JIAOTONG ROAD WUJIANG
                     ECONOMIC-TECHNOLOGICAL JIANGSU PROVINCE
                     P.R.C.




                          Date of Receipt : 2006/08/23
                          Issued Date               : 2006/09/04

                          Report No.                : 068S020




The declaration results relate only to the samples calculated.
The declaration shall not be reproduced except in full without the written approval of QuieTek Corporation.


                                             Page: 1 of 4                                          Version: 1.0


                                                                                           Report No. 066L049




1.      RF Exposure Evaluation

1.1.    Limits

        According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the
        environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b)
        LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
          Frequency Range        Electric Field         Magnetic Field    Power Density        Average Time
                  (MHz)         Strength (V/m)          Strength (A/m)      (mW/cm2)             (Minutes)
                                    (A) Limits for Occupational/ Control Exposures
              300-1500                   --                      --           F/300                  6
           1500-100,000                  --                      --              5                   6
                              (B) Limits for General Population/ Uncontrolled Exposures
              300-1500                   --                      --           F/1500                 6
           1500-100,000                  --                      --              1                   30
        F= Frequency in MHz


       Friis Formula
       Friis transmission formula: Pd = (Pout*G)/(4*pi*r2)


       Where
       Pd = power density in mW/cm2
       Pout = output power to antenna in mW
       G = gain of antenna in linear scale
       Pi = 3.1416
       R = distance between observation point and center of the radiator in cm


       Pd id the limit of MPE, 1 mW/cm2 . If we know the maximum gain of the antenna and the total power
       input to the antenna, through the calculation, we will know the distance r where the MPE limit is
       reached.



1.2.    Test Procedure

         Software provided by client enabled the EUT to transmit and receive data at lowest, middle and
         highest channel individually.
         The temperature and related humidity: 18℃and 78% RH.



                                                  Page: 2 of 4                                   Version: 1.0


                                                                                            Report No. 066L049


1.3.     Test Result of RF Exposure Evaluation

         Product       :     Home Gateway
         Test Item     :     RF Exposure Evaluation
         Test Site     :     AC-3
         Test Mode     :     Mode 1: Transmit 802.11b

Antenna Gain
Antenna Gain: The maximum Gain measured in fully anechoic chamber is 2dBi or 1.58 in linear scale.


Output Power Into Antenna & RF Exposure Evaluation Distance:


                           Channel Frequency         Output Power to Antenna      Power Density at R = 20 cm
       Channel
                                 (MHz)                         (mW)                        (mW/cm2)

          1                     2402.00                        38.0189                       0.0120

          6                     2437.00                        36.3078                       0.0114

         11                     2462.00                        37.0681                       0.0117


The power density Pd (4th column) at a distance of 20 cm calculated from the Friis transmission formula is far
below the limit of 1 mW/cm2.




                                                Page: 3 of 4                                     Version: 1.0


                                                                                            Report No. 066L049



         Product       :     Home Gateway
         Test Item     :     RF Exposure Evaluation
         Test Site     :     AC-3
         Test Mode     :     Mode 2: Transmit 802.11g

Antenna Gain
Antenna Gain: The maximum Gain measured in fully anechoic chamber is 2dBi or 1.58 in linear scale.


Output Power Into Antenna & RF Exposure Evaluation Distance:


                           Channel Frequency         Output Power to Antenna      Power Density at R = 20 cm
      Channel
                                 (MHz)                         (mW)                        (mW/cm2)

          1                     2402.00                        16.4059                       0.0052

          6                     2441.00                        15.7036                       0.0050

         11                     2480.00                        16.3305                       0.0051


The power density Pd (4th column) at a distance of 20 cm calculated from the Friis transmission formula is far
below the limit of 1 mW/cm2.