Test report 15CE part 4

FCC ID: H8NRT410W

Test Report

Download: PDF
FCCID_385328

FCC ID: H8NRT410W



CHANNEL 8




Report No.: RF921121H01   131   Issued: Dec. 19, 2003


FCC ID: H8NRT410W



For Test result (A) -Dynamic
                             802.11 a/b/g Wireless                       RT410W-
  EUT                                                   MODEL
                             Module                                      D92(LF)
                                                        INPUT POWER
  MODE                       Turbo                                       120Vac, 60 Hz
                                                        (SYSTEM)
  ENVIRONMENTAL              21eg. C, 58RH,
                                                        TESTED BY        Tony Chen
  CONDITIONS                 976 hPa


                           CHANNEL      RF POWER LEVEL IN       MAXIMUM
      CHANNEL
                          FREQUENCY         1 MHz BW             LIMIT      PASS/FAIL
      NUMBER
                            (MHz )            (dBm)              (dBm)
           1                5200                -2.87                4         PASS
           2                5240                -2.64                4         PASS
           3                5280                -1.01               11         PASS




Report No.: RF921121H01                       132                          Issued: Dec. 19, 2003


FCC ID: H8NRT410W



CHANNEL 1




Report No.: RF921121H01   133   Issued: Dec. 19, 2003


FCC ID: H8NRT410W



CHANNEL 2




Report No.: RF921121H01   134   Issued: Dec. 19, 2003


FCC ID: H8NRT410W



CHANNEL 3




Report No.: RF921121H01   135   Issued: Dec. 19, 2003


FCC ID: H8NRT410W



For Test result (B) -Static
                             802.11 a/b/g Wireless                       RT410W-
  EUT                                                   MODEL
                             Module                                      D92(LF)
                                                        INPUT POWER
  MODE                       Turbo                                       120Vac, 60 Hz
                                                        (SYSTEM)
  ENVIRONMENTAL              21eg. C, 58RH,
                                                        TESTED BY        Tony Chen
  CONDITIONS                 976 hPa


                           CHANNEL      RF POWER LEVEL IN       MAXIMUM
      CHANNEL
                          FREQUENCY         1 MHz BW             LIMIT      PASS/FAIL
      NUMBER
                            (MHz )            (dBm)              (dBm)
           1                5210                -3.68                4         PASS
           2                5250                -3.05                4         PASS
           3                5290                -1.36               11         PASS




Report No.: RF921121H01                       136                          Issued: Dec. 19, 2003


FCC ID: H8NRT410W



CHANNEL 1




Report No.: RF921121H01   137   Issued: Dec. 19, 2003


FCC ID: H8NRT410W



CHANNEL 2




Report No.: RF921121H01   138   Issued: Dec. 19, 2003


FCC ID: H8NRT410W



CHANNEL 3




Report No.: RF921121H01   139   Issued: Dec. 19, 2003


FCC ID: H8NRT410W




5.6     FREQUENCY STABILITY

 5.6.1 LIMITS OF FREQUENCY STABILITY MEASUREMENT

The frequency tolerance of the carrier signal shall be maintained within +/- 0.02% of
the operating frequency over a temperature variation of –30 degrees to 50 degrees
C at normal supply voltage, and for a variation in the primary supply voltage from
85% to 115% of the rated supply voltage at a temperature of 20 degrees C.


5.6.2 TEST INSTRUMENTS


Description & Manufacturer             Model No.       Serial No.       Calibrated Until

R&S SPECTRUM ANALYZER                  FSP30           100019           Dec. 19, 2003

NOTE:
The calibration interval of the above test instruments is 12 months and the calibrations are
traceable to NML/ROC and NIST/USA.




5.6.3     TEST PROCEDURE

1. The EUT was placed inside the environmental test chamber and powered by
    nominal AC voltage.
2. Turn the EUT on and couple its output to a spectrum analyzer.
3. Turn the EUT off and set the chamber to the highest temperature specified.
4. Allow sufficient time (approximately 30 min) for the temperature of the chamber to
    stabilize, turn the EUT on and measure the operating frequency after 2, 5, and
    10 minutes.
5. Repeat step 2 and 3 with the temperature chamber set to the lowest temperature.
6. The test chamber was allowed to stabilize at +20 degree C for a minimum of 30
    minutes. The supply voltage was then adjusted on the EUT from 85% to 115%
    and the frequency record.




Report No.: RF921121H01                         140                                Issued: Dec. 19, 2003


FCC ID: H8NRT410W




5.6.4 DEVIATION FROM TEST STANDARD

No deviation



5.6.5 TEST SETUP

                             Temperature


        Spectrum Analyzer




                       AC Power Supply




5.6.6 EUT OPERATING CONDITION


Same as Item 4.1.6




Report No.: RF921121H01                    141   Issued: Dec. 19, 2003


reem menrmniow                                                                          y

56. TEST RESULTS

        Operating frequency: S820MFiz                              Limit : £0,02%
Temp. ::;vpel;             2minute                  S minute                  10 minute
 CC |    waoy          |_(ke)        h        (wie)            h          (wie)         h
          1eas     |_soze ocs oocoscsn| soro orss oocostew sezn orss occomioe
  8        mo      sem0.m5      o ocomiere   sezn orse |   ocosien       soro ores   oo0015%
          sas seze oc« oocosers soro mer oocostew sezn ore| oocomier
          12as se wors |—o oo00er% soro sore |—o coo0s0| sw sore o ovcocrn
  ®        mo      se19 sore    o ooc0iow    sera oor7     |—oconois»    sorpsore    |—oo0oone
          sas_| sera wors o o00er% soro sore |—o coo0sm| sem sore o ovcocrn
          12a5 sor oosz o comzen| soro soos| o cooreme| semm ons| o oovreen
  ®        mo      519 onse     o oooiren    sero ooge     |—ocomiace    sor sns     .0 o00r20%
          sas_| se oosz o comzen sor seor o coorien som onor o ooomien
          12a5 se soss |—o conoss» soro soss o coo0s0m| smm soss o oocneon
  ®        mo      se19 ons     .o ooonon    sero oose     |—ononoge»    sorp sons   .o ooo0sine
          sa.s_| sera soss o conossn| soro sons|.o coo0eom| smm sose o ovconon
          12as se oose o comaen soro sons o cooram| sw onse o ooontree
  ®®       mo      519 onse     o oooiren    sero oous     |—ocomiaze|   sorp sns    |—o0o017%
          sas_| sera oous o comzew soro soos|.o coore0e| sem onor o ooomien
          12a5 sora ooss o comtoon soro aoes |.o cooroo| smm ons o ooon00%
   °       mo      se19 ome     o ooot0s%    sero oace     |—ocomtors    sor se      |—0 000100
          sas sera woce o comtos% soro ues |.o cooro0| smm oner o ooor00%
          1eas |_seze oo« ooccorey sernoer oo00077% sez0 ons occonsme
  ®        mo      sem0.00e_|   o oco0ren|   sezn ooce     ooosoret|     sero.oors   ooo0051%
          sas seznoost ooocorre| sore oote onovorow sezn ons occonsme
          12a5 sezoiss oocosien sore ons« onooston sezn orse occosson
  *        mo      sem oise     o ocosiere   sezn oies     ocosie%       soro oes    0000000%
          sas sezeoiss oocosien sore orns| onoossom sezn orss occosson
          1eas sezore oocossen sezn on ooc0sor» sez0 o2e0 oococien
  ®        mo      sem0.019_|   o oconsm%    sen orto      ooodeten      sez oete    000005%
          sas      sezn ore oocossen sez oere | oncososn sezn o2en occocien



Raserto: nesertemmor                          we                                  lsnd ts 1, z000


FCC ID: H8NRT410W



5.7     BAND EDGES MEASUREMENT



5.7.1 TEST INSTRUMENTS


  Description & Manufacturer           Model No.       Serial No.       Calibrated Until

 R&S SPECTRUM ANALYZER                    FSP        1093.4495.30         Dec. 19, 2003

NOTE:
 1.The measurement uncertainty is less than +/- 2.6dB, which is calculated as per the NAMAS
   document NIS81.
 2.The calibration interval of the above test instruments is 12 months and the calibrations are
   traceable to NML/ROC and NIST/USA.




5.7.2 TEST PROCEDURE

The transmitter output was connected to the spectrum analyzer via a low lose cable.
Set RBW of spectrum analyzer to 1MHz and VBW of spectrum analyzer to 300Hz
with suitable frequency span including 100 MHz bandwidth from band edge. The
band edges was measured and recorded.



5.7.3 EUT OPERATING CONDITION


The software provided by client to enable the EUT under transmission condition
continuously at specific channel frequencies individually.




Report No.: RF921121H01                       143                               Issued: Dec. 19, 2003


FCC ID: H8NRT410W




5.7.4 TEST RESULTS

For signals in the restricted bands above and below the 5.15 to 5.35 GHz allocated
band a measurement was made of the amplitude of the spurious emissions with
respect to the intentional signals. The relative amplitude, in dBc, was applied to the
average and peak filed strength of the intentional signal made on the OATS to
calculate the field strength of the unintentional signals.


The spectrum plots (Average RBW=1MHz, VBW=300Hz) are attached on the
following 6 pages.




Report No.: RF921121H01                   144                           Issued: Dec. 19, 2003


FCC ID: H8NRT410W




Normal Mode: Channel 1 (5180 MHz)

The band edge emission plot on the following page shows 49.1dBc (Average) between carrier
maximum power and local maximum emission in restrict band. The emission of carrier strength list in
the test result of channel 1 (normal mode) is 94.1dBuV/m, so the maximum field strength in restrict
band is 94.1-49.1=45dBuV/m which is under 54dBuV/m limit.




Report No.: RF921121H01                         145                                Issued: Dec. 19, 2003


FCC ID: H8NRT410W


Normal Mode: Channel 8 (5320 MHz)

The band edge emission plot on the following page shows 53.28dBc (Average) between carrier
maximum power and local maximum emission in restrict band. The emission of carrier strength list in
the test result of channel 8 (normal mode) is 96.9dBuV/m, so the maximum field strength in restrict
band is 96.9-53.28=43.62dBuV/m which is under 54dBuV/m limit.




Report No.: RF921121H01                         146                                Issued: Dec. 19, 2003


FCC ID: H8NRT410W



For Test result (A) -Dynamic
Turbo Mode: Channel 1 (5200 MHz)

The band edge emission plot on the following page shows 42.79dBc (Average) between carrier
maximum power and local maximum emission in restrict band. The emission of carrier strength list in
the test result of channel 1 (turbo mode) is 92.3dBuV/m, so the maximum field strength in restrict
band is 92.3-42.79=49.51dBuV/m which is under 54dBuV/m limit.




Report No.: RF921121H01                         147                                Issued: Dec. 19, 2003


FCC ID: H8NRT410W



Turbo Mode: Channel 3 (5280 MHz)

The band edge emission plot on the following page shows 52.4dBc (Average) between carrier
maximum power and local maximum emission in restrict band. The emission of carrier strength list in
the test result of channel 1 (turbo mode) is 95.8dBuV/m, so the maximum field strength in restrict
band is 95.8-52.4=43.4dBuV/m which is under 54dBuV/m limit.




Report No.: RF921121H01                         148                                Issued: Dec. 19, 2003


FCC ID: H8NRT410W


For Test result (B) -Static
Turbo Mode: Channel 1 (5210 MHz)

The band edge emission plot on the following page shows 47.62dBc (Average) between carrier
maximum power and local maximum emission in restrict band. The emission of carrier strength list in
the test result of channel 3 (turbo mode) is 82.6dBuV/m, so the maximum field strength in restrict
band is 82.6-47.62=34.98dBuV/m which is under 54dBuV/m limit.




Report No.: RF921121H01                         149                                Issued: Dec. 19, 2003


FCC ID: H8NRT410W


Turbo Mode: Channel 3 (5290 MHz)

The band edge emission plot on the following page shows 49.25dBc (Average) between carrier
maximum power and local maximum emission in restrict band. The emission of carrier strength list in
the test result of channel 3 (turbo mode) is 94.9dBuV/m, so the maximum field strength in restrict
band is 94.9-49.25=45.65dBuV/m which is under 54dBuV/m limit.




Report No.: RF921121H01                         150                                Issued: Dec. 19, 2003


FCC ID: H8NRT410W




5.8     ANTENNA REQUIREMENT

5.8.1 STANDARD APPLICABLE

For intentional device, according to FCC 47 CFR Section 15.203, an intentional
radiator shall be designed to ensure that no antenna other than that furnished by
the responsible party shall be used with the device.
And according to FCC 47 CFR Section 15.407(a), if transmitting antennas of
directional gain greater than 6dBi are used, the power shall be reduced by the
amount in dB that the directional gain of the antenna exceeds 6dBi.




5.8.2 ANTENNA CONNECTED CONSTRUCTION

The antenna used in this product is shape Antenna without connector. The
maximum Gain of the antenna is 0dBi.




Report No.: RF921121H01                151                          Issued: Dec. 19, 2003


FCC ID: H8NRT410W



 6. PHOTOGRAPHS OF THE TEST CONFIGURATION
                          CONDUCTED EMISSION TEST




Report No.: RF921121H01              152            Issued: Dec. 19, 2003


FCC ID: H8NRT410W




                          RADIATED EMISSION TEST




Report No.: RF921121H01             153            Issued: Dec. 19, 2003


FCC ID: H8NRT410W




 7. INFORMATION ON THE TESTING LABORATORIES

We, ADT Corp., were founded in 1988 to provide our best service in EMC and
Safety consultation. Our laboratories are accredited and approved by the following
approval agencies according to ISO/IEC 17025, Guide 25 or EN 45001:

   USA                    FCC, NVLAP, UL
   Germany                TUV Rheinland
   Japan                  VCCI
   New Zealand            MoC
   Norway                 NEMKO
   R.O.C.                 BSMI, DGT, CNLA

Copies of accreditation certificates of our laboratories obtained from approval
agencies can be downloaded from our web site:
www.adt.com.tw/index.5/phtml.

If you have any comments, please feel free to contact us at the following:

   Lin Kou EMC Lab:                    Hsin Chu EMC Lab:
   Tel: 886-2-26052180                 Tel: 886-35-935343
   Fax: 886-2-26052943                 Fax: 886-35-935342

   Lin Kou Safety Lab:                 Lin Kou RF&Telecom Lab
   Tel: 886-2-26093195                 Tel: 886-3-3270910
   Fax: 886-2-26093184                 Fax: 886-3-3270892

   Email: service@mail.adt.com.tw
   Web Site: www.adt.com.tw

The address and road map of all our labs can be found in our web site also.




Report No.: RF921121H01                     154                         Issued: Dec. 19, 2003



Document Created: 2003-12-23 17:04:48
Document Modified: 2003-12-23 17:04:48

© 2025 FCC.report