RF Exposure info

FCC ID: H8N-WLU6120

RF Exposure Info

Download: PDF
FCCID_1144923

1.1. Test Result of RF Exposure Evaluation
      . Product: WiFi module
      . Test Item: RF Exposure Evaluation Data
      . Test Mode: Normal Operation


1.1.1. Antenna Gain

     Antenna 1:       PCB Antenna,        2.86dBi
     Antenna 2:       PCB Antenna,        2.74dBi
     Antenna 3:       PCB Antenna,        2.19dBi
     Antenna 4:       PCB Antenna,        2.50dBi
     Antenna 5:       PCB Antenna,        0.77dBi


1.1.2. EUT Operation condition

     Software provided by client enabled the EUT to transmit and receive data at lowest,
     middle and highest channel individually.
1.1.3. Output Power into Antenna & RF Exposure Evaluation Distance

      Test Date: Jul. 14, 2009         Temperature: 27℃      Humidity: 64%
   Modulation                    Frequency     Out put power to Antenna        Power Density (S)
                   Channel
    Standard                       (MHz)                (dBm)                     (mW/cm2)
                       01           2412                 18.53                      0.027
    802.11b
    (1Mbps)            06           2437                 18.15                      0.025
                       11           2462                 18.20                      0.025
                       01           2412                 19.69                      0.036
    802.11g
    (6Mbps)            06           2437                 23.23                      0.081
                       11           2462                 19.57                      0.035
    802.11n,           01           2412                 18.16                      0.025
      HT20             06           2437                 23.46                      0.085
   (6.5Mbps)           11           2462                 17.21                      0.020
     802.11n,         03            222                  15.63                       0.014
      HT40            06           2437                  23.77                       0.092
   (13.5Mbps)         09           2452                  15.51                       0.014

 The MPE is calculated as 0.085mW / cm2 < limit 1 mW / cm2. So, RF exposure limit
 warning or SAR test are not required.

 For 2412-2462 MHzhe EUT will only be used with a separation of 20cm or greater
 between the antenna and nearby persons and can therefore be considered a mobile
 transmitter per 47CFR2.1091 (b).

 The RF Exposure Information page from the manual is included here for reference.



Document Created: 2009-07-21 17:53:49
Document Modified: 2009-07-21 17:53:49

© 2025 FCC.report