MPE 1 of 2

FCC ID: H8N-WLU5080

RF Exposure Info

Download: PDF
FCCID_1385063

FCC TEST REPORT                       Report No.: FR0N1923AC




      Appendix A. Maximum Permissible Exposure




                                      Page No.   : A1 of A3
                                      FCC ID     : H8N-WLU5080


FCC TEST REPORT                                                                               Report No.: FR0N1923AC


1. Maximum Permissible Exposure
1.1. Applicable Standard

    Systems operating under the provisions of this section shall be operated in a manner that ensures that the
    public is not exposed to radio frequency energy levels in excess limit for maximum permissible exposure. In
    accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as a mobile device
    whereby a distance of 0.2 m normally can be maintained between the user and the device.
    (A) Limits for Occupational / Controlled Exposure
                                                                                                         Averaging Time
     Frequency Range             Electric Field       Magnetic Field      Power Density (S)
                                                                                                          |E|²,|H|² or S
          (MHz)                Strength (E) (V/m)   Strength (H) (A/m)       (mW/ cm²)
                                                                                                            (minutes)
            0.3-3.0                   614                  1.63                   (100)*                        6
            3.0-30                  1842 / f              4.89 / f               (900 / f)*                     6
            30-300                    61.4                0.163                       1.0                       6
           300-1500                                                               F/300                         6
        1500-100,000                                                                   5                        6
    (B) Limits for General Population / Uncontrolled Exposure
                                                                                                         Averaging Time
     Frequency Range             Electric Field       Magnetic Field      Power Density (S)
                                                                                                          |E|²,|H|² or S
          (MHz)                Strength (E) (V/m)   Strength (H) (A/m)       (mW/ cm²)
                                                                                                            (minutes)
           0.3-1.34                   614                  1.63                   (100)*                       30
            1.34-30                  824/f                2.19/f                  (180/f)*                     30
            30-300                   27.5                 0.073                       0.2                      30
           300-1500                                                               F/1500                       30
        1500-100,000                                                                  1.0                      30
    Note: f = frequency in MHz ; *Plane-wave equivalent power density

1.2. MPE Calculation Method

                30  P  G                                                      E2
    E (V/m) =                                  Power Density:     Pd (W/m²) =
                    d                                                           377
    E = Electric field (V/m)
    P = Peak RF output power (W)
    G = EUT Antenna numeric gain (numeric)
    d = Separation distance between radiator and human body (m)
    The formula can be changed to

    Pd =
           30  P  G
            377  d 2
    From the peak EUT RF output power, the minimum mobile separation distance, d=0.2m, as well as the gain of
    the used antenna, the RF power density can be obtained.


                                                                                              Page No.     : A2 of A3
                                                                                              FCC ID       : H8N-WLU5080


FCC TEST REPORT                                                         Report No.: FR0N1923AC


1.3. Calculated Result and Limit

    Antenna Type : Printed Antenna
    Max Conducted Power for IEEE 802.11a: 23.81dBm
                                                                                           Power
      Test     Min. User                                  Conducted     Conducted
                              Gain (dBi)   Numeric Gain                                   Density
      Mode   Distance (cm)                                Power (dBm)   Power (mW)
                                                                                         (mW/cm2)
       5G         20             5.16        3.280953        23.81       240.4363          0.1570


    Max Conducted Power for IEEE 802.11b/g: 25.01dBm
                                                                                           Power
      Test     Min. User                                  Conducted     Conducted
                              Gain (dBi)   Numeric Gain                                   Density
      Mode   Distance (cm)                                Power (dBm)   Power (mW)
                                                                                         (mW/cm2)
      2.4G        20                 2.7     1.862087        25.01       316.9567          0.1175




                                                                        Page No.    : A3 of A3
                                                                        FCC ID      : H8N-WLU5080



Document Created: 2010-11-29 14:26:23
Document Modified: 2010-11-29 14:26:23

© 2024 FCC.report