RF Exposure Info

FCC ID: H8N-DPR2320G

RF Exposure Info

Download: PDF
FCCID_389331

               Ecom Sertech Corp.
                                                                   FCC ID :H8N-DPR2320G
                Rm. 258, Bldg. 17, NO.195, Sec. 4 Chung Hsing
                Rd.,Chu
                   - Tung Chen, Hsinchu, Taiwan 310, R.O.C
                                                                   Report No.:ER03-11-049FRF
                TEL:886 - 3 - 5918012 FAX : 886 - 3- 5825720       Page    1    of    2



RF EXPOSURE EVALUATION

 According to FCC 1.1310 : The criteria listed in the following table shall be used to evaluate the
 environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b)
 LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)

  Frequency Range       Electric Field      Magnetic Field      Power Density
                                                                                Average Time
       (MHz)           Strength (V/m)       Strength (A/m)       (mW/cm2)
                        (A) Limits for Occupational / Control Exposures
   300-1,500                   --                   --              F/300              6
   1,500-100,000               --                   --               5                 6
                    (B) Limits for General Population / Uncontrol Exposures
   300-1,500                   --                   --             F/1500              6
   1,500-100,000               --                   --               1                30



  Friis Formula

        Friis transmission formula : Pd = (Pout*G)/(4*pi*r2)
        Where
        Pd = power density in mW/cm2
        Pout = output power to antenna in mW
        G = gain of antenna in linear scale
        Pi = 3.1416
        R = distance between observation point and center of the radiator in cm
        Pd id the limit of MPE, 1 mW/cm2. If we know the maximum gain of the antenna and the
        total power input to the antenna, through the calculation, we will know the distance r
        where the MPE limit is reached.


  EUT Operating Condition

        A software provided by client enabled the EUT to transmit and receive data at lowest,
        middle and highest channel individually.


                  Ecom Sertech Corp.
                                                                          FCC ID :H8N-DPR2320G
                   Rm. 258, Bldg. 17, NO.195, Sec. 4 Chung Hsing
                   Rd.,Chu
                      - Tung Chen, Hsinchu, Taiwan 310, R.O.C
                                                                          Report No.:ER03-11-049FRF
                   TEL:886 - 3 - 5918012 FAX : 886 - 3- 5825720           Page    2    of    2



   Test Result of RF Exposure Evaluation

           Test Item : RF Exposure Evaluation Data
           Test Mode : Normal Operation


   Antenna Gain

           Antenna Gain:The maximum Gain measured in fully anechoic chamber is 3dBi
                             linear scale.


   Output Power into Antenna & RF Exposure Evaluation Distance


                                       Output Power to             Power Density
              Channel Frequency                                                           LIMITS
 Channel                                  Antenna                     at 20cm
                   (MHz)                                                                 (mW/cm2)
                                           (dBm)                     (mW/cm2)
   CH1              2412.00                  17.15                   0.020593                 1
   CH6              2437.00                  17.60                   0.022842                 1
   CH11             2462.00                  17.92                   0.024588                 1
Note : 1. For Antenna 1 802.11b Mode (11Mbps).
      2. The power density Pd (4th column) at a distance of 20cm calculated from the Friis transmission
        formula is far below the limit of 1 mW/cm2 . The EUT is classified as mobile product. So, RF
        exposure limit warning or SAR test are not required.



                                       Output Power to             Power Density
              Channel Frequency                                                           LIMITS
 Channel                                  Antenna                     at 20cm
                   (MHz)                                                                 (mW/cm2)
                                           (dBm)                     (mW/cm2)
   CH1              2412.00                  13.80                   0.009522                 1
   CH6              2437.00                  15.10                   0.012845                 1
   CH11             2462.00                  15.40                   0.013764                 1
Note : 1. For Antenna 1 802.11g Mode (6Mbps).
      2. The power density Pd (4th column) at a distance of 20cm calculated from the Friis transmission
        formula is far below the limit of 1 mW/cm2 . The EUT is classified as mobile product. So, RF
        exposure limit warning or SAR test are not required.



Document Created: 2003-12-29 17:15:35
Document Modified: 2003-12-29 17:15:35

© 2024 FCC.report