RF EXPOSURE EVALUATION

 According to FCC 1.1310 : The criteria listed in the following table shall be used to evaluate the
 environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b)
 LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)

  Frequency Range       Electric Field      Magnetic Field      Power Density
                                                                                Average Time
       (MHz)           Strength (V/m)       Strength (A/m)       (mW/cm2)
                        (A) Limits for Occupational / Control Exposures
   300-1,500                   --                   --              F/300              6
   1,500-100,000               --                   --               5                 6
                    (B) Limits for General Population / Uncontrol Exposures
   300-1,500                   --                   --             F/1500              6
   1,500-100,000               --                   --               1                30



 Friis Formula

        Friis transmission formula : Pd = (Pout*G)/(4*pi*r2)
        Where
        Pd = power density in mW/cm2
        Pout = output power to antenna in mW
        G = gain of antenna in linear scale
        Pi = 3.1416
        R = distance between observation point and center of the radiator in cm
        Pd id the limit of MPE, 1 mW/cm2. If we know the maximum gain of the antenna and the
        total power input to the antenna, through the calculation, we will know the distance r
        where the MPE limit is reached.


 EUT Operating Condition

        A software provided by client enabled the EUT to transmit and receive data at lowest,
        middle and highest channel individually.


                   Ecom Sertech Corp.
                                                                      FCC ID :H8N-DPR2320
                   Rm. 258, Bldg. 17, NO.195, Sec. 4 Chung Hsing
                   Rd.,Chu
                      - Tung Chen, Hsinchu, Taiwan 310, R.O.C
                                                                      Report No.:ER03-07-049FRF-1
                   TEL:886 - 3 - 5918012 FAX : 886 - 3- 5825720        Page     2   of    2



 Test Result of RF Exposure Evaluation

          Test Item : RF Exposure Evaluation Data
          Test Mode : Normal Operation


 Antenna Gain

          Antenna Gain:The maximum Gain measured in fully anechoic chamber is 2.0dBi
          linear scale.


 Output Power into Antenna & RF Exposure Evaluation Distance

                                                               Power density in
                                       Output Power to
             Channel Frequency                                 mW/cm2 at Friis
Channel                                   Antenna                                        LIMITS
                  (MHz)                                         formula when
                                           (dBm)              r=20cm(mW/cm2)
 CH1                2412.00                  17.68                 0.018481                  1
 CH6                2437.00                  17.37                 0.017208                  1
 CH11               2462.00                  16.90                 0.015443                  1
       The power density Pd (4th column) at a distance of 20cm calculated from the Friis transmission
       formula is far belowthe limit of 1 mW/cm2 . So, RF exposure limit warning or SAR test are not
       required.