              RF Exposure Evaluation Report


                APPLICANT               KP ELECTRONIC SYSTEMS LTD.
                                               P.O. BOX 42
                                   TEFEN INDUSTRIAL PARK 24959 ISRAEL
                      FCC ID                       H78KPMT2W
          MODEL NUMBER                                MT2W
                PRODUCT                VHF AUTOMATIC METER READING
             DESCRIPTION                TRANSCEIVER W/ 2.4 GHZ TX.
     STANDARD APPLIED                          CFR 47 Part 2.1091
             PREPARED BY                          Cory Leverett


We, TIMCO ENGINEERING, INC. would like to declare that the device has been
evaluated in accordance with 47 CFR Part 2.1091 and meets the requirements.

The attached report shall not be reproduced except in full without the written
approval of TIMCO ENGINEERING, INC.


GENERAL REMARKS


Attestations

This equipment has been evaluated in accordance with the standards identified in
this report. To the best of my knowledge and belief, these evaluations were
performed using the procedures described in this report.

I attest that the necessary evaluations were made, under my supervision, at:

Timco Engineering Inc.
849 NW State Road 45
Newberry, FL 32669




Authorized Signatory Name:

Cory Leverett

Engineering Project Manager

Date: 9/28/2015




Applicant: KP ELECTRONIC SYSTEMS LTD.
FCC ID:    H78KPMT2W
Report:    K\KP H78\2010AUT15\2010AUT15TestReport.docxt
                                                                        Page 2 of 4


                       RF Exposure Requirements

General information

Device type: VHF AUTOMATIC METER READING TRANSCEIVER W/ 2.4 GHZ TX.

Devices that operate under Part 90 of this chapter are subject to RF exposure
evaluation prior to equipment authorization or use.

Antenna

The manufacturer does not specify an antenna, but a typical antenna has a gain of
0 dBi.


     Configuration      Antenna p/n            Type                      Max. Gain (dBi)
    Fixed mounted           Any                omni                             0


Operating confiquration and exposure conditions:

The conducted output power is shown in the table below. Typical use qualifies for a
maximum duty cycle factor of 100%.




Nom. Attenuation for RG 213/U:
                     Frequency              Attenuation per 100ft.
                        MHz                           dB
                          1                          .27
                         10                          .55
                         50
                        100
                        200
                        400
                        700
                        900
                       1000
                       4000

MPE Calculation:

The minimum separation distance is calculated as follows:


                              (30xPxG                                :      E
                     E(V m) = ————          Power dersity. P,(mIW /em ) =
                                 d                   e                      3770


The limit for general uncontrolled exposure environment is shown in FCC rule Part
1.11310, Table 1.



                               Minimum Separation Distance for Mobile or Fixed Devices
                                               Controlled Exposure

                  Insert values in yellow highlighted boxes to determine Minimum Separation Distance
Max Power                         2W           equals     Max Power                 2000 mW
Duty Cycle                     100 %           equals     Duty Factor                  1 numeric
Antenna Gain                      0 dBi        equals     Gain numeric                 1 numeric
Coax Loss                         0 dB                    Gain - Coax Loss             1 numeric
                                          2
Power Density                  1 mW/cm
Enter power Density from the chart to the right                   Rule Part 1.1310, Table 1 (A)
Frequency                  173.5 MHz                   Freq range       Power density Enter this value
                                                              MHz             mW/cm2         mW/cm
                                                                                                       2

                                                             0.3 - 3           100            100
                                                               3 - 30         900/f2            0.0
                                                              30-300            1                1
                                                            300-1,500         f/300             0.6
                                                         1,500-100,000          5                5
                                                       f = frequency in MHz


Minimum Separation Distance                                            13 cm                      0.13 m
Minimum Seperation in Inches       4.963002 Inches