Test report

FCC ID: H5OT51

Test Report

Download: PDF
FCCID_1480894

             Compliance Certification Services Inc.
             Report No.: T110330201-RP1           FCC ID: H5OT51               Date of Issue: June 9, 2011



                         FCC 47 CFR PART 15 SUBPART C


                                       TEST REPORT


                                               For


                                  Car Alarm Transmitter


                                       Model: TX731A


                         Brand Name: Advance Security Inc.

                                             Issued to

                                   Advance Security Inc.
                        3F, 48 Ta An Street, Hsi Chih, Taipei Hsien,
                                     TAIWAN R.O.C.

                                             Issued by

                       Compliance Certification Services Inc.
                                  Sindian Lab.
                           No.163-1, Jhongsheng Rd, Sindian City,
                           Taipei County 23151, Taiwan (R.O.C.)
                                    TEL: (02) 2217-0894
                                    FAX: (02) 2217-1029




Note: This report shall not be reproduced except in full, without the written approval of Compliance
 Certification Services Inc. This document may be altered or revised by Compliance Certification
      Services Inc. personnel only, and shall be noted in the revision section of the document.



                                               Page 1                                       Total Page: 27
                                                                                                  Rev. 00


                      Compliance Certification Services Inc.
                      Report No.: T110330201-RP1                              FCC ID: H5OT51                              Date of Issue: June 9, 2011




                                                TABLE OF CONTENTS
1. TEST RESULT CERTIFICATION............................................................................................. 3

2. EUT DESCRIPTION .................................................................................................................... 4

3. TEST METHODOLOGY ............................................................................................................. 5
   3.1       EUT CONFIGURATION .............................................................................................................. 5
   3.2       EUT EXERCISE ......................................................................................................................... 5
   3.3       GENERAL TEST PROCEDURES .................................................................................................. 5
   3.4       FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS ............................................. 6
   3.5       DESCRIPTION OF TEST MODES ................................................................................................. 6

4. INSTRUMENT CALIBRATION................................................................................................. 7
   4.1       MEASURING INSTRUMENT CALIBRATION ........................................................................... 7
   4.2       MEASUREMENT EQUIPMENT USED .............................................................................. 7

5. FACILITIES AND ACCREDITATIONS ................................................................................... 8
   5.1       FACILITIES .............................................................................................................................. 8
   5.2       EQUIPMENT ............................................................................................................................. 8
   5.3       TABLE OF ACCREDITATIONS AND LISTINGS ............................................................................ 9

6. SETUP OF EQUIPMENT UNDER TEST .................................................................................. 9
   6.1       SETUP CONFIGURATION OF EUT .............................................................................................. 9
   6.2       SUPPORT EQUIPMENT .............................................................................................................. 9

7. FCC PART 15.231 REQUIREMENTS...................................................................................... 10
   7.1       20DB BANDWIDTH ........................................................................................................... 10
   7.2       LIMIT OF TRANSMISSION TIME .............................................................................................. 12
   7.3       DUTY CYCLE CORRECTION FACTOR.......................................................................... 14
   7.4       RADIATED EMISSIONS ........................................................................................................... 17
   7.5       POWERLINE CONDUCTED EMISSIONS .................................................................................... 24

APPENDIX I PHOTOGRAPHS OF TEST SETUP ....................................................................... 25




                                                                         Page 2                                                                     Rev. 00


                Compliance Certification Services Inc.
                Report No.: T110330201-RP1          FCC ID: H5OT51               Date of Issue: June 9, 2011




1. TEST RESULT CERTIFICATION

Applicant:                       Advance Security Inc.
                                 3F, 48 Ta An Street, Hsi Chih, Taipei Hsien,
                                 TAIWAN R.O.C.
Equipment Under Test:            Car Alarm Transmitter
Brand Name:                      Advance Security Inc.
Model:                           TX731A
Date of Test:                    June 4, 2011 & June 7, 2011
                                 APPLICABLE STANDARDS
                   STANDARD                                          TEST RESULT
         FCC 47 CFR Part 15 Subpart C                          No non-compliance noted


We hereby certify that:
The above equipment was tested by Compliance Certification Services Inc. Sindian BU. The test
data, data evaluation, test procedures, and equipment configurations shown in this report were
made in accordance with the procedures given in ANSI C63.4: 2009 and the energy emitted by
the sample EUT tested as described in this report is in compliance with conducted and radiated
emission limits of FCC Rules Part 15.207, 15.209 and Part 15.231.
The test results of this report relate only to the tested sample identified in this report.




                                                 Page 3                                             Rev. 00


              Compliance Certification Services Inc.
              Report No.: T110330201-RP1         FCC ID: H5OT51           Date of Issue: June 9, 2011




2. EUT DESCRIPTION
Product                           Car Alarm Transmitter

Brand Name                        Advance Security Inc.

Model Number                      TX731A

Modulation Technique              ASK

Power Supply                      6VDC Battery

Frequency Range                   433.92 MHz

Antenna Specification             Helical Antenna / Gain: -2.5dbi

Associated Receiver               H5OTR45

Remark:
   1.     The sample selected for test was production product and was provided by
          manufacturer.
   2.     This submittal(s) (test report) is intended for FCC ID: H5OT51 filing to comply with
          Section 15.207, 15.209 and 15.231 of the FCC Part 15, Subpart C Rules.




                                             Page 4                                          Rev. 00


              Compliance Certification Services Inc.
              Report No.: T110330201-RP1        FCC ID: H5OT51             Date of Issue: June 9, 2011



3. TEST METHODOLOGY
The tests documented in this report were performed in accordance with ANSI C63.4 (2009) and
FCC CFR 47 2.1046, 2.1047, 2.1049, 2.1051, 2.1053, 2.1055, 2.1057, 15.207, 15.209 and
15.231.
3.1 EUT CONFIGURATION
The EUT configuration for testing is installed on RF field strength measurement to meet the
Commissions requirement and operating in a manner that intends to maximize its emission
characteristics in a continuous normal application.
3.2 EUT EXERCISE
The EUT was operated in the engineering mode to fix the TX frequency that was for the purpose
of the measurements.
3.3 GENERAL TEST PROCEDURES
Conducted Emissions
The EUT is placed on the turntable, which is 0.8 m above ground plane. According to the
requirements in Section 13.1.4.1 of ANSI C63.4. Conducted emissions from the EUT measured
in the frequency range between 0.15 MHz and 30MHz using CISPR Quasi-peak and average
detector modes.

Radiated Emissions
The EUT is placed on a turn table, which is 0.8 m above ground plane. The turntable shall rotate
360 degrees to determine the position of maximum emission level. EUT is set 3m away from the
receiving antenna, which varied from 1m to 4m to find out the highest emission. And also, each
emission was to be maximized by changing the polarization of receiving antenna both horizontal
and vertical. In order to find out the maximum emissions, exploratory radiated emission
measurements were made according to the requirements in Section 13.1.4.1 of ANSI C63.4.




                                             Page 5                                           Rev. 00


                Compliance Certification Services Inc.
                Report No.: T110330201-RP1        FCC ID: H5OT51            Date of Issue: June 9, 2011




3.4 FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS
(a) Except as shown in paragraph (d) of this section, only spurious emissions are permitted in
    any of the frequency bands listed below:

               MHz                      MHz                  MHz                    GHz
           0.090 - 0.110          16.42 - 16.423           399.9 - 410           4.5 - 5.15
           1
           0.495 - 0.505       16.69475 - 16.69525          608 - 614            5.35 - 5.46
         2.1735 - 2.1905       16.80425 - 16.80475         960 - 1240            7.25 - 7.75
          4.125 - 4.128            25.5 - 25.67            1300 - 1427           8.025 - 8.5
        4.17725 - 4.17775          37.5 - 38.25           1435 - 1626.5           9.0 - 9.2
        4.20725 - 4.20775            73 - 74.6           1645.5 - 1646.5          9.3 - 9.5
          6.215 - 6.218             74.8 - 75.2            1660 - 1710           10.6 - 12.7
        6.26775 - 6.26825          108 - 121.94          1718.8 - 1722.2        13.25 - 13.4
        6.31175 - 6.31225           123 - 138              2200 - 2300          14.47 - 14.5
          8.291 - 8.294           149.9 - 150.05           2310 - 2390          15.35 - 16.2
          8.362 - 8.366            156.52475 -            2483.5 - 2500          17.7 - 21.4
        8.37625 - 8.38675           156.52525              2655 - 2900          22.01 - 23.12
        8.41425 - 8.41475         156.7 - 156.9            3260 - 3267           23.6 - 24.0
          12.29 - 12.293        162.0125 - 167.17          3332 - 3339           31.2 - 31.8
       12.51975 - 12.52025        167.72 - 173.2          3345.8 - 3358         36.43 - 36.5
       12.57675 - 12.57725          240 - 285              3600 - 4400                (2)
          13.36 - 13.41            322 - 335.4
   1
       Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz.
   2
       Above 38.6

(b) Except as provided in paragraphs (d) and (e), the field strength of emissions appearing within
    these frequency bands shall not exceed the limits shown in Section 15.209. At frequencies
    equal to or less than 1000 MHz, compliance with the limits in Section 15.209 shall be
    demonstrated using measurement instrumentation employing a CISPR quasi-peak detector.
    Above 1000 MHz, compliance with the emission limits in Section 15.209 shall be
    demonstrated based on the average value of the measured emissions. The provisions in
    Section 15.35 apply to these measurements.
3.5 DESCRIPTION OF TEST MODES
The EUT (model: TX731A) had been tested under engineering test mode condition and the EUT
staying in continuous transmitting mode.
The field strength of spurious emission was measured in the following position: EUT stand-up
position (Z axis), lie-down position (X, Y axis). The worst emission was found in lie-down
position (Y axis) and the worst case was recorded.




                                               Page 6                                           Rev. 00


               Compliance Certification Services Inc.
               Report No.: T110330201-RP1       FCC ID: H5OT51                   Date of Issue: June 9, 2011




4. INSTRUMENT CALIBRATION
4.1 MEASURING INSTRUMENT CALIBRATION
The measuring equipment, which was utilized in performing the tests documented herein, has
been calibrated in accordance with the manufacturer's recommendations for utilizing calibration
equipment, which is traceable to recognized national standards
4.2 MEASUREMENT EQUIPMENT USED
Equipment Used for Emissions Measurement
Remark: Each piece of equipment is scheduled for calibration once a year.
                                 Open Area Test Site Chamber #D
   Name of Equipment       Manufacturer          Model          Serial Number            Calibration Due
  MEASURE RECEIVER          SCHAFFNER           SCR3501                342                  06/28/2011
        ANTENNA
                               SUNOL              JB1                A022310                10/04/2011
      (30-1000MHz)
         PRE-
                                EMCI            EMC330                980022                01/20/2012
       AMPLIFIER
         CABLE                 HUBER
                                             SUCOFLEX 102             33105/2               01/20/2012
      (30-1000MHz)            +SUHNER
         CABLE
                                EMCI           EMCI-C-14             CH-D#13                01/20/2012
      (30-1000MHz)
     ATTENUATOR                 MCL            BW-S6W5               CH-D#14                01/20/2012
    LOOP ANTENNA               EMCO               6502               8905-2356              06/10/2013
 SPECTRUM ANALYZER
                                R&S              FSP 30               100112                12/07/2011
      (9kHz-30GHz)
 SPECTRUM ANALYZER
                               Agilent          E4446A              MY48250064              12/29/2011
      (9kHz-40GHz)
       ANTENNA
                               EMCO               3115               00022256               01/09/2012
       (1-18GHz)
       AMPLIFIER
                                 HP              8449B              3008A01266              12/19/2011
        (1-18GHz)
        CABLE                  HUBER
                                             SUCOFLEX 102             33106/2               12/19/2011
       (1-40GHz)              +SUHNER
         CABLE                 HUBER
                                             SUCOFLEX 102             33633/2               12/19/2011
       (18-40GHz)             +SUHNER
         CABLE                 HUBER
                                            SUCOFLEX 104PEA         33959/4PEA              12/19/2011
       (1-26.5GHz)            +SUHNER
         CABLE                 HUBER
                                            SUCOFLEX 104PEA         33960/4PEA              12/19/2011
       (1-26.5GHz)            +SUHNER
       THERMO-
                              TECPEL            DTM-303                NO.3                 11/18/2011
     HYGRO METER
        Test S/W                                           EZ-EMC




                                             Page 7                                                 Rev. 00


                 Compliance Certification Services Inc.
                 Report No.: T110330201-RP1             FCC ID: H5OT51                 Date of Issue: June 9, 2011



4.3 MEASUREMENT UNCERTAINTY
                   PARAMETER                                  UNCERTAINTY
  3M Semi Anechoic Chamber / 30M~1000M                               ± 3.98
  3M Semi Anechoic Chamber / 1G~18G                                  ± 1.99
  3M Semi Anechoic Chamber / 18G~26G                                 ± 2.65
  3M Semi Anechoic Chamber / 26G~40G                                 ± 2.97

Remark: This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level
         using a coverage factor of k=2.



5. FACILITIES AND ACCREDITATIONS
5.1 FACILITIES
All measurement facilities used to collect the measurement data are located at

    No.163-1, Jhongsheng Rd, Sindian City, Taipei County 23151, Taiwan (R.O.C.)
    Tel: 886-2-2217-0894 / Fax: 886-2-2217-1029

    No.11, Wugong 6th Rd., Wugu Industrial Park, Taipei Hsien 248, Taiwan
    Tel: 886-2-2299-9720 / Fax: 886-2-2298-4045

    No.81-1, Lane 210, Bade 2nd Rd., Luchu Hsiang, Taoyuan Hsien 338, Taiwan
    Tel: 886-3-324-0332 / Fax: 886-3-324-5235
The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.4 and
CISPR Publication 22.
5.2 EQUIPMENT
Radiated emissions are measured with one or more of the following types of linearly polarized
antennas: tuned dipole, biconical, log periodic, bi-log, and/or ridged waveguide, horn. Spectrum
analyzers with pre-selectors and quasi-peak detectors are used to perform radiated
measurements.
Conducted emissions are measured with Line Impedance Stabilization Networks and EMI Test
Receivers.
Calibrated wideband preamplifiers, coaxial cables, and coaxial attenuators are also used for
making measurements.
All receiving equipment conforms to CISPR 16-1-1, CISPR 16-1-2, CISPR 16-1-3, CISPR
16-1-4 and CISPR 16-1-5.




                                                     Page 8                                               Rev. 00


                 Compliance Certification Services Inc.
                 Report No.: T110330201-RP1              FCC ID: H5OT51                  Date of Issue: June 9, 2011




5.3 TABLE OF ACCREDITATIONS AND LISTINGS
  Country       Agency                        Scope of Accreditation                                  Logo
                            3M Semi Anechoic Chamber (FCC MRA: TW1039) to perform
 USA         FCC
                            FCC Part 15 measurements
                                                                                             250366
                            LP0002, RTTE01, FCC Method-47 CFR Part 15 Subpart C, D, E,
                            RSS-210, RSS-310
                            IDA TS SRD, AS/NZS 4268, AS/NZS 4771, TS 12.1 & 12,2,
                            ETSI EN 300 440-1, ETSI EN 300 440-2, ETSI EN 300 328,
                            ETSI EN 300 220-1, ETSI EN 300 220-2, ETSI EN 301 893,
                            ETSI EN 301 489-1/3/7/17
 Taiwan      TAF
                            FCC OET Bulletin 65 + Supplement C,
                            EN 50360, EN 50361, EN 50371, RSS 102, EN 50383, EN 50385,
                            EN 50392, IEC 62209, CNS 14958-1, CNS 14959
                            FCC Method –47 CFR Part 15 Subpart B
                            IEC / EN 61000-3-2, IEC / EN 61000-3-3,
                            IEC / EN 61000-4-2/3/4/5/6/8/11

 Canada      Industry Canada 3M Semi Anechoic Chamber (IC 2324G-1 / IC 2324G-2) to perform
                                                                                             IC 2324D-1
* No part of this report may be used to claim or imply product endorsement by A2LA any agency of the US
  Government.



6. SETUP OF EQUIPMENT UNDER TEST
6.1 SETUP CONFIGURATION OF EUT
See test photographs attached in Appendix I for the actual connections between EUT and support
equipment.
6.2 SUPPORT EQUIPMENT
 No. Device Type       Brand          Model        Series No.        FCC ID          Data Cable        Power Cord


Remark:
    1. All the equipment/cables were placed in the worst-case configuration to maximize the
       emission during the test.
    2. Grounding was established in accordance with the manufacturer’s requirements and
       conditions for the intended use.




                                                      Page 9                                                 Rev. 00


              Compliance Certification Services Inc.
              Report No.: T110330201-RP1         FCC ID: H5OT51           Date of Issue: June 9, 2011



7. FCC PART 15.231 REQUIREMENTS
7.1 20DB BANDWIDTH

LIMIT
The bandwidth of the emission shall be no wider than 0.25% of the center frequency for devices
operating above 70 MHz and below 900 MHz. For devices operating above 900 MHz, the
emission shall be no wider than 0.5% of the center frequency. Bandwidth is determined at the
points 20 dB down from the modulated carrier.
Test Configuration


                       Spectrum
    EUT                Analyzer



TEST PROCEDURE
The transmitter output is connected to the spectrum analyzer. The spectrum analyzer center
frequency is set to the transmitter frequency. The RBW is set to 10 kHz and VBW is set 30kHz.
TEST RESULTS
No non-compliance noted.

Test Data
 Frequency 20 dB Bandwidth            Limit
                                                    Result
   (MHz)        (kHz)                (MHz)
   433.92            63.50           1.0848         PASS




                                              Page 10                                        Rev. 00


            Compliance Certification Services Inc.
            Report No.: T110330201-RP1      FCC ID: H5OT51   Date of Issue: June 9, 2011



Test Plot




                                         Page 11                                Rev. 00


              Compliance Certification Services Inc.
              Report No.: T110330201-RP1          FCC ID: H5OT51           Date of Issue: June 9, 2011




7.2 LIMIT OF TRANSMISSION TIME

LIMIT
According to 15.231 (a)(1), a manually operated transmitter shall employ a switch that will
automatically deactivate the transmitter within not more than 5 seconds of being released.
Test Configuration

                       Spectrum
     EUT               Analyzer



TEST PROCEDURE
The transmitter output is connected to the spectrum analyzer. The spectrum analyzer center
frequency is set to the transmitter frequency. The RBW and VBW are set to 100kHz.
TEST RESULTS
No non-compliance noted

Test Data
                Transmission
 Frequency                            Limit
                    time                             Result
   (MHz)                            (Second)
                  (Second)
   433.92           2.00              5.00               PASS




                                               Page 12                                        Rev. 00


            Compliance Certification Services Inc.
            Report No.: T110330201-RP1      FCC ID: H5OT51   Date of Issue: June 9, 2011



Test Plot




                                         Page 13                                Rev. 00


               Compliance Certification Services Inc.
               Report No.: T110330201-RP1         FCC ID: H5OT51         Date of Issue: June 9, 2011




7.3 DUTY CYCLE CORRECTION FACTOR

LIMIT
Nil (No dedicated limit specified in the Rules)

Test Configuration

                       Spectrum
     EUT               Analyzer




TEST PROCEDURE
1. Place the EUT on the table and set it in transmitting mode.
2. Remove the antenna from the EUT and then connect a low loss RF cable from the antenna
   port to the spectrum analyzer.
3. Set center frequency of spectrum analyzer = operating frequency.
4. Set the spectrum analyzer as RBW, VBW=100KHz, Span = 0Hz, Adjust Sweep = 100ms.
5. Repeat above procedures until all frequency measured were complete.

TEST RESULTS
No non-compliance noted

Test Data
Tp = 68.00ms
Ton = (0.82*2)+(0.24*45) = 12.44
Duty Cycle Correction Factor= 20* log (Ton / Tp) = 20* log (12.44/68.00) = -14.753 dB




                                              Page 14                                       Rev. 00


            Compliance Certification Services Inc.
            Report No.: T110330201-RP1      FCC ID: H5OT51   Date of Issue: June 9, 2011



Test Plot
Tp




Channel Number




                                         Page 15                                Rev. 00


        Compliance Certification Services Inc.
        Report No.: T110330201-RP1      FCC ID: H5OT51   Date of Issue: June 9, 2011




Ton 1




Ton 2




                                     Page 16                                Rev. 00


               Compliance Certification Services Inc.
               Report No.: T110330201-RP1          FCC ID: H5OT51              Date of Issue: June 9, 2011




7.4 RADIATED EMISSIONS

LIMIT
1. According to §15.231(b), in addition to the provisions of Section 15.205, the field strength of
   emissions from intentional radiators operated under this Section shall not exceed the
   following:
                                             Field Strength of       Field Strength of Spurious
       Fundamental Frequency
                                              Fundamental                     Emissions
              (MHz)
                                            (microvolts/meter)           (microvolts/meter)
              40.66 – 40.70                        2250                             225
                70 – 130                           1250                             125
                130 – 174                     1250 to 3750 **                  125 to 375 **
                174 – 260                          3750                             375
                260 – 470                     3750 to 12500 **                 375 to 1250 **
               Above 470                           12500                            1250
   Remark: ** linear interpolations
   [Where F is the frequency in MHz, the formulas for calculating the maximum permitted fundamental
   field strengths are as follows: for the band 130-174 MHz, uV/m at 3 meters = 56.81818(F) -
   6136.3636; for the band 260-470 MHz, uV/m at 3 meters = 41.6667(F) - 7083.3333. The maximum
   permitted unwanted emission level is 20 dB below the maximum permitted fundamental level.]
2. Except as provided elsewhere in this Subpart, the emissions from an intentional radiator shall
   not exceed the field strength levels specified in the following table:
              Frequency                       Field Strength           Measurement Distance
                (MHz)                            (mV/m)                        (m)
                  30-88                            100*                               3
                 88-216                            150*                               3
                 216-960                           200*                               3
               Above 960                            500                               3
   Remark: Except as provided in paragraph (g), fundamental emissions from intentional
   radiators operating under this Section shall not be located in the frequency bands 54-72
   MHz, 76-88 MHz, 174-216 MHz or 470-806 MHz. However, operation within these
   frequency bands is permitted under other sections of this Part, e.g., Sections 15.231 and
   15.241.
3. In the above emission table, the tighter limit applies at the band edges.
              Frequency                       Field Strength                Field Strength
                (MHz)                       (µV/m at 3-meter)            (dBµV/m at 3-meter)
                  30-88                             100                              40
                 88-216                             150                             43.5
                 216-960                            200                              46
               Above 960                            500                              54




                                                Page 17                                           Rev. 00


               Compliance Certification Services Inc.
               Report No.: T110330201-RP1       FCC ID: H5OT51              Date of Issue: June 9, 2011



Test Configuration
9kHz ~ 30MHz




                             3m
                                                                    Loop antenna
       EUT

                                                                  Spectrum /
                                                                   Receiver


             Turntable                  1m
                            0.8m




   Reference ground plane

Below 1 GHz

                                                                  Antenna
                                                                   tower


                             3m                                    Bi-log
                                                                  antenna
       EUT
                                   4m
                                                                 Spectrum
                                                                 analyzer


             Turntable                  1m
                            0.8m




   Reference ground plane




                                             Page 18                                           Rev. 00


               Compliance Certification Services Inc.
               Report No.: T110330201-RP1        FCC ID: H5OT51               Date of Issue: June 9, 2011



Above 1 GHz

                                                                  Antenna
                                                                   tower


                     3m                                        Horn
                                                              antenna
   EUT
                           4m
                                                              Spectrum
                                                              analyzer


       Turntable                1m
                    0.8m
                                                                    Pre-amp




TEST PROCEDURE
1. The EUT is placed on a turntable, which is 0.8m above ground plane.
2. The turntable shall be rotated for 360 degrees to determine the position of maximum
   emission level.
3. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find out
   the highest emissions.
4. Maximum procedure was performed on the six highest emissions to ensure EUT compliance.
5. And also, each emission was to be maximized by changing the polarization of receiving
   antenna both horizontal and vertical.
6. Set the spectrum analyzer in the following setting as:
   Below 1GHz:
                   RBW=100kHz / VBW=300kHz / Sweep=AUTO
   Above 1GHz:
                   (a) PEAK: RBW=VBW=1MHz / Sweep=AUTO
                   (b) AVERAGE: RBW=1MHz / VBW=10Hz / Sweep=AUTO
7. Repeat above procedures until the measurements for all frequencies are complete.




                                              Page 19                                            Rev. 00


               Compliance Certification Services Inc.
               Report No.: T110330201-RP1      FCC ID: H5OT51             Date of Issue: June 9, 2011



TEST RESULTS
No non-compliance noted

Below 1 GHz
Operation Mode: TX Mode / Button#1                    Test Date: June 4, 2011
Temperature:       26oC                               Humidity: 60% RH
Tested by:         Howard Pang                        Polarity: Ver. / Hor.


    Freq.        Pk R dg        A v R dg    Factor         Level        L imit      M argin        Pol
   (M H z)       (dB uV)        (dB uV)      (dB )       (dB uV/m)    (dB uV/m)      (dB )        (H /V)
   434.49         55.63          40.84      -8.09           32.75       80.84        -48.10        V _X
   868.08         38.52          23.73      -1.56           22.17       60.83        -38.66        V _X
   434.49         54.28          39.49      -8.09           31.40       80.84        -49.45        V _Y
   868.08         38.53          23.74      -1.56           22.18       60.83        -38.65        V _Y
   434.49         53.90          39.11      -8.09           31.02       80.84        -49.83        V _Z
   869.05         39.29          24.50      -1.55           22.95       60.83        -37.88        V _Z

   434.49         52.63          37.84      -8.09           29.75       80.84        -51.10        H _X
   868.08         40.96          26.17      -1.56           24.61       60.83        -36.22        H _X
   434.49         52.47          37.68      -8.09           29.59       80.84        -51.26        H _Y
   869.05         39.55          24.76      -1.55           23.21       60.83        -37.62        H _Y
   434.49         53.19          38.40      -8.09           30.31       80.84        -50.54        H _Z
   868.08         39.05          24.26      -1.56           22.70       60.83        -38.13        H _Z

Factor = Antenna Factor + C able Loss - Pre Am plifier
Av Rdg = Pk Rdg-14.753dB


Remark:
   1. No emission found between lowest internal used/generated frequency to 30MHz
       (9kHz~30MHz)
   2. Radiated emissions measured in frequency range from 30 MHz to 1000MHz were made
       with an instrument using peak/quasi-peak/average detector mode.
   3. Average/quasi-peak test would be performed if the peak result were greater than the
       average/quasi-peak limit or as required by the applicant.
   4. Data of measurement within this frequency range shown “ --- ” in the table above
       means the reading of emissions are attenuated more than 20dB below the permissible
       limits or the field strength is too small to be measured.
   5. Measurements above show only up to 6 maximum emissions noted, or would be lesser,
       with “ N/A ” remark, if no specific emissions from the EUT are recorded (ie:
       margin>20dB from the applicable limit) and considered that's already beyond the
       background noise floor.
   6. Margin (dB) = Level (dBuV/m) – Limit (dBuV/m).


                                            Page 20                                           Rev. 00


               Compliance Certification Services Inc.
               Report No.: T110330201-RP1               FCC ID: H5OT51                Date of Issue: June 9, 2011




Operation Mode: TX Mode / Button#2                           Test Date: June 4, 2011
Temperature:         26oC                                    Humidity: 60% RH
Tested by:           Howard Pang                             Polarity: Ver. / Hor.


   Freq.       Pk Rdg       A v R dg       F a c to r      L evel        L im it      M a r g in       P ol
  (M H z )     (d B u V )   (d B u V )      (d B )      (d B u V /m ) (d B u V /m )    (d B )         (H /V )
  4 3 4 .4 9    5 0 .3 1     3 5 .5 2       -8 .0 9          2 7 .4 3    8 0 .8 4     -5 3 .4 2       V _X
  8 6 8 .0 8    3 7 .7 9     2 3 .0 0       -1 .5 6          2 1 .4 4    6 0 .8 3     -3 9 .3 9       V _X
  4 3 4 .4 9    5 1 .2 5     3 6 .4 6       -8 .0 9          2 8 .3 7    8 0 .8 4     -5 2 .4 8       V _Y
  8 6 9 .0 5    3 8 .6 9     2 3 .9 0       -1 .5 5          2 2 .3 5    6 0 .8 3     -3 8 .4 8       V _Y
  4 3 4 .4 9    5 0 .6 0     3 5 .8 1       -8 .0 9          2 7 .7 2    8 0 .8 4     -5 3 .1 3       V _Z
  8 6 9 .0 5    3 9 .1 5     2 4 .3 6       -1 .5 5          2 2 .8 1    6 0 .8 3     -3 8 .0 2       V _Z

  4 3 4 .4 9    5 2 .5 6     3 7 .7 7       -8 .0 9          2 9 .6 8    8 0 .8 4     -5 1 .1 7       H _X
  8 6 8 .0 8    3 9 .5 0     2 4 .7 1       -1 .5 6          2 3 .1 5    6 0 .8 3     -3 7 .6 8       H _X
  4 3 4 .4 9    5 2 .7 2     3 7 .9 3       -8 .0 9          2 9 .8 4    8 0 .8 4     -5 1 .0 1       H _Y
  8 6 8 .0 8    3 9 .6 9     2 4 .9 0       -1 .5 6          2 3 .3 4    6 0 .8 3     -3 7 .4 9       H _Y
  4 3 4 .4 9    5 2 .1 2     3 7 .3 3       -8 .0 9          2 9 .2 4    8 0 .8 4     -5 1 .6 1       H _Z
  8 6 8 .0 8    3 8 .4 6     2 3 .6 7       -1 .5 6          2 2 .1 1    6 0 .8 3     -3 8 .7 2       H _Z
F a c to r = A n te n n a F a c to r + C a b le L o ss - P re A m p lifie r
A v R d g = P k R d g -1 4 .7 5 3 d B

Remark:
    1. No emission found between lowest internal used/generated frequency to 30MHz
        (9kHz~30MHz)
    2. Radiated emissions measured in frequency range from 30 MHz to 1000MHz were made
        with an instrument using peak/quasi-peak/average detector mode.
    3. Average/quasi-peak test would be performed if the peak result were greater than the
        average/quasi-peak limit or as required by the applicant.
    4. Data of measurement within this frequency range shown “ --- ” in the table above
        means the reading of emissions are attenuated more than 20dB below the permissible
        limits or the field strength is too small to be measured.
    5. Measurements above show only up to 6 maximum emissions noted, or would be lesser,
        with “ N/A ” remark, if no specific emissions from the EUT are recorded (ie:
        margin>20dB from the applicable limit) and considered that's already beyond the
        background noise floor.
    6. Margin (dB) = Level (dBuV/m) – Limit (dBuV/m).




                                                   Page 21                                               Rev. 00


               Compliance Certification Services Inc.
               Report No.: T110330201-RP1      FCC ID: H5OT51              Date of Issue: June 9, 2011




Operation Mode: TX Mode / Button#3 / WORST Test Date: June 4, 2011
Temperature:       26oC                               Humidity: 60% RH
Tested by:         Howard Pang                        Polarity: Ver. / Hor.


    Freq.         Pk Rdg        Av R dg     Factor           L evel      L imit       M argin             Pol
   (M H z)        (dB uV )      (dB uV)      (dB )         (dB uV/m)   (dB uV /m)      (dB )             (H /V)

   434.49         51.63          36.84      -8.09           28.75       80.84         -52.10             V _X
   869.05         37.80          23.01      -1.55           21.46       60.83         -39.37             V _X
   434.49         50.81          36.02      -8.09           27.93       80.84         -52.92             V _Y
   869.05         37.40          22.61      -1.55           21.06       60.83         -39.77             V _Y
   434.49         49.98          35.19      -8.09           27.10       80.84         -53.75             V _Z
   868.08         37.14          22.35      -1.56           20.79       60.83         -40.04             V _Z

   434.49         52.28          37.49      -8.09           29.40       80.84         -51.45             H _X
   869.05         37.74          22.95      -1.55           21.40       60.83         -39.43             H _X
   434.49         54.76          39.97      -8.09           31.88       80.84         -48.97             H _Y
   868.08         38.61          23.82      -1.56           22.26       60.83         -38.57             H _Y
   434.49         54.93          40.14      -8.09           32.05       80.84         -48.80             H _Z
   868.08         38.34          23.55      -1.56           21.99       60.83         -38.84             H _Z
Factor = Antenna Factor + Cable Loss - Pre Am plifier
Av Rdg = Pk Rdg-14.753dB

Remark:
    1. No emission found between lowest internal used/generated frequency to 30MHz
        (9kHz~30MHz)
    2. Radiated emissions measured in frequency range from 30 MHz to 1000MHz were
        made with an instrument using peak/quasi-peak/average detector mode.
    3. Average/quasi-peak test would be performed if the peak result were greater than the
        average/quasi-peak limit or as required by the applicant.
    4. Data of measurement within this frequency range shown “ --- ” in the table above
        means the reading of emissions are attenuated more than 20dB below the permissible
        limits or the field strength is too small to be measured.
    5. Measurements above show only up to 6 maximum emissions noted, or would be lesser,
        with “ N/A ” remark, if no specific emissions from the EUT are recorded (ie:
        margin>20dB from the applicable limit) and considered that's already beyond the
        background noise floor.
    6. Margin (dB) = Level (dBuV/m) – Limit (dBuV/m).




                                            Page 22                                           Rev. 00


                  Compliance Certification Services Inc.
                  Report No.: T110330201-RP1                      FCC ID: H5OT51                     Date of Issue: June 9, 2011




Above 1 GHz
Operation Mode:                   TX / Button#3                   Test Date:                      June 7, 2011
Temperature:                      26oC                            Tested by:                      60% RH
Humidity:                         Howard Pang                     Polarity:                       Ver. / Hor.

     F req.          Pk R dg         A v R dg        F a c to r         L evel          L im it        M a r g in       P ol
    (M H z )         (d B u V )      (d B u V )       (d B )         (d B u V /m )   (d B u V /m )      (d B )         (H /V )
   1 3 0 2 .0 0       3 4 .1 0             ---        -8 .7 0          2 5 .3 6        7 4 .0 0        -4 8 .6 4          V
   1 3 0 2 .0 0         ---                ---          ---              ---           5 4 .0 0           ---             V
   1 7 3 6 .0 0       3 5 .9 0           2 1 .1 1     -6 .2 0          1 4 .8 9        6 0 .8 3        -4 5 .9 5          V
   2 1 7 0 .0 0       3 2 .4 0           1 7 .6 1     -4 .0 0          1 3 .6 2        6 0 .8 0        -4 7 .1 9          V

   1 3 0 2 .0 0       3 4 .0 0             ---        -8 .7 0          2 5 .2 6        7 4 .0 0        -4 8 .7 4          H
   1 3 0 2 .0 0         ---                ---          ---              ---           5 4 .0 0           ---             H
   1 7 3 6 .0 0       3 6 .2 0           2 1 .4 1     -6 .2 0          1 5 .1 9        6 0 .8 0        -4 5 .6 2          H
   2 1 7 0 .0 0       3 1 .8 0           1 7 .0 1     -4 .0 0          1 3 .0 2        6 0 .8 0        -4 7 .7 9          H

F a c to r = A n te n n a F a c to r + C a b le L o ss - P r e A m p lifie r

Remark:
   1. Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental
        frequency.
   2. Radiated emissions measured in frequency above 1000MHz were made with an
        instrument using peak/average detector mode.
   3. Average test would be performed if the peak result were greater than the average limit
        or as required by the applicant.
   4. Data of measurement within this frequency range shown “ --- ” in the table above
        means the reading of emissions are attenuated more than 20dB below the permissible
        limits or the field strength is too small to be measured.
   5. Measurements above show only up to 6 maximum emissions noted, or would be lesser,
        with “ N/A ” remark, if no specific emissions from the EUT are recorded (ie:
        margin>20dB from the applicable limit) and considered that's already beyond the
        background noise floor.
   6. Margin (dB) = Level (dBuV/m) – Limit (dBuV/m).




                                                           Page 23                                                      Rev. 00


              Compliance Certification Services Inc.
              Report No.: T110330201-RP1           FCC ID: H5OT51          Date of Issue: June 9, 2011



7.5 POWERLINE CONDUCTED EMISSIONS

LIMIT
According to §15.207(a), except as shown in paragraphs (b) and (c) of this section, for an
intentional radiator that is designed to be connected to the public utility (AC) power line, the
radio frequency voltage that is conducted back onto the AC power line on any frequency or
frequencies within the band 150 kHz to 30 MHz shall not exceed the limits in the following table,
as measured using a 50 µH/50 ohms line impedance stabilization network (LISN). Compliance
with the provisions of this paragraph shall be based on the measurement of the radio frequency
voltage between each power line and ground at the power terminal. The lower limit applies at the
boundary between the frequency ranges.

       Frequency Range                                     Limits (dBµV)
            (MHz)                          Quasi-peak                        Average
           0.15 to 0.50                      66 to 56*                      56 to 46*
            0.50 to 5                              56                            46
             5 to 30                               60                            50
* Decreases with the logarithm of the frequency.


Test Configuration
See test photographs attached in Appendix 1 for the actual connections between EUT and
support equipment.


Test Procedure

Not applicable (Since the EUT is powered by battery)

TEST RESULTS
Not applicable (Since the EUT is powered by battery)




                                             Page 24                                          Rev. 00


       Compliance Certification Services Inc.
       Report No.: T110330201-RP1       FCC ID: H5OT51   Date of Issue: June 9, 2011


APPENDIX I-PHOTOGRAPHS OF TEST SETUP
RADIATED EMISSION SET UP PHOTOS
                                    TX Mode
                                     X axis




                                     Y axis




                                     Page 25                                Rev. 00


ne 9, 2011


        Compliance Certification Services Inc.
        Report No.: T110330201-RP1      FCC ID: H5OT51   Date of Issue: June 9, 2011




RADIATED EMISSION SET UP PHOTOS




                                     Page 27                                Rev. 00



Document Created: 2011-06-09 16:38:38
Document Modified: 2011-06-09 16:38:38

© 2024 FCC.report