Test Report ------------------------------------------------------------------------------ 1/12

     FCC ID : H38UT-86P

     Test Procedure:
     The test procedure used was ANSI/TAI/EIA – 603 STADNARD.


(1)Frequency: 794.900 MHz

  Angle of        Spectrum       Corrected      Actually         E. R. P.         8 Position
 Turn Table        Reading                       Value                            of Average
    ( °)            (dBm)          (dB)          (dBm)            (mW)               (mW)
             0°          -5.23         -5.25           0.02       1.00
            45°          -5.99         -5.25          -0.74       0.84
            90°          -4.31         -5.25           0.94       1.24
           135°          -4.63         -5.25           0.62       1.15               0.95
           180°          -5.10         -5.25           0.15       1.03
           225°         -20.53         -5.25         -15.28       0.03
           270°          -3.85         -5.25           1.40       1.38
           315°          -5.42         -5.25          -0.17       0.96


(2)Frequency: 800.200 MHz

  Angle of        Spectrum       Corrected      Actually         E. R. P.         8 Position
 Turn Table        Reading                       Value                            of Average
    ( °)            (dBm)          (dB)          (dBm)            (mW)               (mW)
             0°          -6.52         -5.25          -1.27       0.74
            45°          -8.86         -5.25          -3.61       0.43
            90°          -8.12         -5.25          -2.87       0.51
           135°          -5.31         -5.25          -0.06       0.98               0.68
           180°          -5.33         -5.25           0.08       1.01
           225°         -13.63         -5.25          -8.38       0.14
           270°          -5.13         -5.25           0.12       1.02
           315°          -7.46         -5.25          -2.21       0.61




Report No.: S0774792
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440


Test Report ------------------------------------------------------------------------------ 2/12


(3)Frequency: 804.90 MHz

  Angle of        Spectrum       Corrected      Actually         E. R. P.         8 Position
 Turn Table        Reading                       Value                            of Average
    ( °)            (dBm)          (dB)        (dBμV/m)           (mW)               (mW)
             0°          -4.18         -5.29           1.07       1.27
            45°          -6.79         -5.29          -1.50       0.70
            90°          -4.75         -5.29           0.54       1.13
           135°          -2.20         -5.29           3.09       2.03               1.31
           180°          -5.57         -5.29          -0.28       0.93
           225°          -7.23         -5.29          -1.94       0.63
           270°          -2.26         -5.29           3.03       2.00
           315°          -2.71         -5.29           2.58       1.81




Report No.: S0774792
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440


Test Report ------------------------------------------------------------------------------ 3/12


Measurement Result:
    ( Test Frequency: 794.900MHz , Horizontal , 30 MHz ~ 1 GHz )

Test Conditions:
       Testing room :        Temperature : 26 °C            Humidity : 73 % RH
       Testing site :        Temperature : 31 °C            Humidity : 75 % RH



                                                                                Attenuated    minimum
                 Reading        Ant.     Table     Correction      Corrected
 Frequency                                                                       below the   Attenuation
                 Amplitude     Height               Factors         Power
                                                                                mean power      limit

    MHz            dBm           m       degree       dB             dBm            dB           dB


    198.727           33.57       1.00      136            -4.65       -48.65     48.43        14.39

    397.452           27.91       1.00       57            -6.09       -47.23     47.01        14.39

           ***




Note:
        1. Corrected Amplitude = Reading Amplitude – Correction Factors
        2. Mean Power = 10 log (p) (dB) = 10 log ( 0.95) = -0.22
            Attenuated below the mean power = P – Corrected Power
            (For example : -0.22 – ( - 48.65) ) = 48.43 (dB) )
        3. Attenuation required = 43 + 10 log ( 1.38 mW ) = 44.39




Report No.: S0774792
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440


Test Report ------------------------------------------------------------------------------ 4/12


Measurement Result:
   ( Test Frequency: 794.900MHz , Horizontal , 1GHz ~ 18GHz )


                 Radiated                      Correction                    Attenuated  minimum
                 Emission                       Factors      Corrected
                                                                             below the  Attenuation
 Frequency Amplitude Ant. H.                                 Amplitude
                                      Table                                  mean power    Limit
                                                 ( dB )
   (GHz)     (dBm)    (cm)            ( °)                     dBm
                                                                                (dB)        (dB)


       1.589      -38.84       1.00       32         -4.67          -34.17          33.95         14.39

       2.380      -31.80       1.00     224          1.32           -33.12            32.9        14.39

       2.770      -31.16       1.00       34         2.69           -33.85          33.63         14.39
       2.980      -16.33       1.00       48         3.42           -19.75          19.53         14.39
         ***




Report No.: S0774792
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440


Test Report ------------------------------------------------------------------------------ 5/12


Measurement Result:
    ( Test Frequency: 794.900MHz , Vertical , 30MHz ~ 1GHz )


 Frequency      Reading       Ant.    Table       Correction                  Attenuated       minimum
                                                                Corrected
                Amplitude    Height                Factors                    below the       Attenuation
                                                                 Power
                                                                              mean power         limit
    MHz           dBm          m      degree        dB/m          dBm            dB               dB



    198.727         -49.06     3.96           8         -3.12        -45.94           45.72     14.39

    397.451         -52.00     1.00       45            -7.52        -44.48           44.26     14.39

          ***




Report No.: S0774792
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440


Test Report ------------------------------------------------------------------------------ 6/12



Measurement Result:
   ( Test Frequency: 794.900MHz , Vertical , 1GHz ~ 18GHz )

                 Radiated                      Correction                     Attenuated       minimum
                 Emission                       Factors      Corrected
                                                                              below the       Attenuation
 Frequency Amplitude Ant. H.                                 Amplitude
                                      Table                                   mean power         Limit
                                                 ( dB )
   (GHz)     (dBm)    (cm)            ( °)                     dBm
                                                                                 (dB)             (dB)


       1.589      -36.96       1.00     134          -5.64          -31.32            31.10       14.39

       2.380      -38.38       1.00     327          -1.05          -37.33            37.11       14.39

       2.770      -48.41       1.00       50         -0.94          -47.47            47.25       14.39
       2.980      -36.41       1.00       94         -0.87          -35.54            35.32       14.39
         ***




Report No.: S0774792
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440


Test Report ------------------------------------------------------------------------------ 7/12



Measurement Result:
( Test Frequency: 800.200MHz , Horizontal , 30MHz ~ 1GHz )

 Frequency       Reading       Ant.    Table       Correction                  Attenuated     minimum
                                                                 Corrected
                 Amplitude    Height                Factors                    below the     Attenuation
                                                                  Power
                                                                               mean power       limit
    MHz            dBm          m      degree        dB/m          dBm            dB             dB



    200.049          -49.77     1.00      150            -3.11        -46.66         44.99        13.08

    400.100          -57.16     2.47           7         -7.54        -49.62         47.95        13.08

    600.148          -48.32     1.00       84            -4.53        -43.79         42.12        13.08

           ***




Note:
        1. Corrected Amplitude = Reading Amplitude – Correction Factors
        2. Mean Power = 10 log (p) (dB) = 10 log ( 0.68) = -1.67
            Attenuated below the mean power = P – Corrected Power
            (For example 794.9MHz : (-0.22) – ( - 48.65) ) = 48.43 (dB) )
        3. Attenuation required = 43 + 10 log ( 1.02 mW ) = 13.08




Report No.: S0774792
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440


Test Report ------------------------------------------------------------------------------ 8/12



Measurement Result:
( Test Frequency: 800.200MHz , Horizontal , 1GHz ~ 18GHz )

                 Radiated                      Correction                    Attenuated minimum
                 Emission                       Factors      Corrected
                                                                             below the Attenuation
 Frequency Amplitude Ant. H.                                 Amplitude
                                      Table                                  mean power   Limit
                                                 ( dB )
   (GHz)     (dBm)    (cm)            ( °)                     dBm
                                                                                (dB)       (dB)


       1.400      -34.13       1.00        9         -4.63           -29.5          27.83         13.08
       1.600      -35.12       1.00     141          -5.91          -29.21          27.54         13.08
       2.390      -32.49       1.00       95         -1.05          -31.44          29.77         13.08
       2.790      -38.46       1.00     417          -0.93          -37.53          35.86         13.08
       3.000      -29.81       1.00     206          -0.87          -28.94          27.27         13.08
       3.190      -35.98       1.00        4         -1.49          -34.49          32.82         13.08
       5.990      -74.26       1.00     189        -36.39           -37.87           36.2         13.08
       6.800      -74.82       1.00     206        -38.08           -36.74          35.07         13.08
       7.410      -79.39       1.00       40       -40.87           -38.52          36.85         13.08
       7.610      -78.67       1.00     146        -41.35           -37.32          35.65         13.08
         ***




Report No.: S0774792
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440


Test Report ------------------------------------------------------------------------------ 9/12



Measurement Result:
 ( Test Frequency: 800.200MHz , Vertical , 30MHz ~ 1GHz )

 Frequency      Reading       Ant.    Table    Correction                    Attenuated        minimum
                                                              Corrected
                Amplitude    Height             Factors                       below the       Attenuation
                                                                Power
                                                                             mean power          limit
    MHz           dBm          m      degree     dB/m            dBm             dB               dB



    200.052         -54.20     2.44       56          -5.14         -49.06            47.39        13.08

    600.152         -51.37     1.00       13          -5.33         -46.04            47.71        13.08

          ***




Report No.: S0774792
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440


Test Report ------------------------------------------------------------------------------ 10/12



Measurement Result:
 ( Test Frequency: 800.200MHz , Vertical , 1GHz ~ 18GHz )

                 Radiated                      Correction                    Attenuated minimum
                 Emission                       Factors      Corrected
                                                                             below the Attenuation
 Frequency Amplitude Ant. H.                                 Amplitude
                                      Table                                  mean power   Limit
                                                 ( dB )
   (GHz)     (dBm)    (cm)            ( °)                     dBm
                                                                                (dB)       (dB)


       1.400       -33.3       2.44       10         -3.79          -29.51          31.18          13.08

       1.600      -40.35       1.00       58         -4.85           -35.5          37.17          13.08

       2.390      -31.23       1.00     151          -1.36          -29.87          31.54          13.08
       2.790       -24.6       1.00     206          -2.76          -21.84          23.51          13.08

       3.000      -21.91       1.00       27         -3.49          -18.42          20.09          13.08

       3.190      -32.83       1.00     116          -1.67          -31.16          32.83          13.08

       5.990      -84.09       1.00     237        -35.72           -48.37          50.04          13.08
       6.800       -81.3       1.00     308        -38.32           -42.98          44.65          13.08
       7.000      -83.04       1.00     346        -37.67           -45.37          47.04          13.08
       7.200       -84.8       1.00       15       -38.71           -46.09          47.76          13.08
       7.410      -85.32       1.00       97       -39.80           -45.52          47.19          13.08
       7.610      -81.22       1.00        2       -40.20           -41.02          42.69          13.08




Report No.: S0774792
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440


Test Report ------------------------------------------------------------------------------ 11/12



Measurement Result:
( Test Frequency: 804.900MHz , Horizontal , 30MHz ~ 1GHz )

 Frequency       Reading       Ant.    Table    Correction                   Attenuated       minimum
                                                              Corrected
                 Amplitude    Height             Factors                     below the       Attenuation
                                                                Power
                                                                             mean power         limit
    MHz            dBm          m      degree     dB/m           dBm            dB               dB



    201.227          -47.97     1.00      150         -3.07         -44.90           43.73         16.07

    402.452          -47.68     1.00       28         -7.42         -40.26           37.42         16.07

           ***




Note:
        1. Corrected Amplitude = Reading Amplitude – Correction Factors
        2. Mean Power = 10 log (p) (dB) = 10 log ( 1.31) = 1.17
            Attenuated below the mean power = P – Corrected Power
            (For example 794.9MHz :(-0.22) – ( - 48.65) ) = 48.43 (dB) )
        3. Attenuation required = 43 + 10 log ( 2.03 mW ) = 16.07




Report No.: S0774792
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440


Test Report ------------------------------------------------------------------------------ 12/12



Measurement Result:
( Test Frequency: 804.900MHz , Horizontal , 1GHz ~ 18GHz )

                 Radiated                      Correction                    Attenuated minimum
                 Emission                       Factors      Corrected
                                                                             below the Attenuation
 Frequency Amplitude Ant. H.                                 Amplitude
                                      Table                                  mean power   Limit
                                                 ( dB )
   (GHz)     (dBm)    (cm)            ( °)                     dBm
                                                                                (dB)       (dB)


       1.207      -42.12       1.00       64         -4.51          -37.61          36.44          16.07
       1.609      -36.93       1.00     150          -5.78          -31.15          29.98          16.07
       2.010      -46.94       1.00       29         -1.67          -45.27           44.1          16.07
       2.410      -42.24       1.00     146          -1.04           -41.2          40.03          16.07
       2.810      -39.19       1.00     228          -0.92          -38.27           37.1          16.07
       3.010      -41.17       1.00     339          -0.90          -40.27           39.1          16.07
       3.220      -40.39       1.00        8         -1.59           -38.8          37.63          16.07
         ***




Report No.: S0774792
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440


Test Report ------------------------------------------------------------------------------ 13/12



Measurement Result:
 ( Test Frequency: 804.900MHz , Vertical , 30MHz ~ 1GHz )

 Frequency      Reading       Ant.    Table       Correction                  Attenuated       minimum
                                                                Corrected
                Amplitude    Height                Factors                    below the       Attenuation
                                                                 Power
                                                                              mean power         limit
    MHz           dBm          m      degree        dB/m          dBm            dB               dB



    201.226         -52.68     2.47           4         -5.05        -47.63           46.46        16.07

    402.452         -48.39     1.00           9         -6.11        -42.28           41.11        16.07

          ***




Report No.: S0774792
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440


Test Report ------------------------------------------------------------------------------ 14/12



Measurement Result:
 ( Test Frequency: 804.900MHz , Vertical , 1GHz ~ 18GHz )

                 Radiated                      Correction                    Attenuated minimum
                 Emission                       Factors      Corrected
                                                                             below the Attenuation
 Frequency Amplitude Ant. H.                                 Amplitude
                                      Table                                  mean power   Limit
                                                 ( dB )
   (GHz)     (dBm)    (cm)            ( °)                     dBm
                                                                                (dB)       (dB)


       1.207      -46.09       1.00       35         -3.15          -42.94          44.61          16.07
       1.609      -39.08       1.00       35         -4.71          -34.37          36.04          16.07
       2.010      -46.39       1.00       39         -0.98          -45.41          47.08          16.07
       2.410      -34.30       1.00     167          1.43           -35.73          37.40          16.07
       2.810      -24.68       1.00     229          2.83           -27.51          29.18          16.07
       3.010      -25.58       1.00       64         3.40           -28.98          30.65          16.07
       3.220      -32.61       1.00     181          1.39           -34.00          35.67          16.07
       3.420      -34.49       1.00       38         -0.53          -33.96          35.63          16.07
       3.620      -71.65       1.00     239        -33.09           -33.09          37.39          16.07
         ***