Redo power of EUT to correspondence 21169

FCC ID: H38JW-86P

Test Report

Download: PDF
FCCID_180118

Test Report ------------------------------------------------------------------------------ 1/6



                                Power Output Measurement

A     Rules and Specification Limits

       2.1046(a), ANSI/ TIA/ EIA-603-1992, Paragraph 2.2.1.
       74.861 ( e )( 1 ) : The power of the measured unmodulated carrier power at output of the
       transmitter power amplifier ( antenna input power ) may not exceed the following:
       1. 54 – 72, 76 – 88 and 174 – 216 MHz band 50 mW.
       2. 470 – 608 and 614 – 806 MHz band 250 mW.




B     Test condition and setup

                       Transmitter                              Test
                         antenna                              antenna



              TRANSMITTER                                                              SPECTRUM
               UNDER TEST                                                              ANALYZER




                           Standard Test Site



       1. Measurement was made on anechoic chamber. The EUT system was placed on non-
          conductive turntable which is 0.8 meters height, top surface 1.0 X 1.5 meter. The EUT was
          placed in three direction of the space in order to obtain maximum emission.
       2. Connect the equipment as illustrated. Place the transmitter to be tested on the turntable in the
          standard test site.
       3. Raise and lower the test antenna from 1m to 4m with the transmitter facing the antenna and
          record the highest received signal.
       4. Repeat step (3) for seven additional readings at 45 interval positions of the turn-table.




Report No.: S0774101
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440


Test Report ------------------------------------------------------------------------------ 2/6




                         Half-wave                              Test
                          vertical                            antenna
                         antenna



                 RF SIGNAL                                                             SPECTRUM
                GENERATOR                                                              ANALYZER




                            Standard Test Site




       5. Replace the transmitter under test with a half-wave vertically polarized antenna. The center of
          the antenna should be at the same location as the transmitter under test. Connect the antenna
          to a signal generator with a known output and record the value.


       6. FIa(dBm) = FIr (dBm) – Corrected (dB)
          Corrected (dB) = AF(dB) + [CL(dB) – Amplitude Gain]
          FIa : Actual Field Intensity
          FIr : Reading of the Field Intensity
          AF : Antenna Factor
          CL : Cable Loss




Report No.: S0774101
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440


Test Report ------------------------------------------------------------------------------ 3/6



       7. The field intensity in Watt can then be determined by the following equation:

           P (watt ) = FI 2( Volt ) X d2 (meter) / 49.2
           P : Power in Watt
           D : Measurement Distance ( 3 m )




C. List of test Instrument
                                                                          Calibration Date
Instrument Name          Model No.       Brand            Serial No.      Last time       Next time
EMI Receiver             8546A           HP               3520A00242      06/29/01        06/29/02
RF Filter Section        85460A          HP               3448A00217      06/29/01        06/29/02
Bi-log Antenna           CBL6141A Schaffner                4206           03/09/01        03/09/02
Switch/Control Unit      3488A           HP               N/A             11/20/00        11/20/01
(> 30MHz)
Auto Switch Box          ASB-01          TRC              9904-01         11/20/00        11/20/01
(> 30MHz)
Spectrum Analyzer        8564E           HP               US36433002      08/01/01        08/01/02
Microwave Preamplifier   83051A          HP               3232A00347      08/01/01        08/01/02
Horn Antenna             3115            EMCO             9704 – 5178     08/01/01        08/01/02
Anechoic Chamber (cable calibrated together)                              05/20/01        05/20/02
The level of confidence of 95%, the uncertainty of measurement of radiated emission is ± 4.96 dB.




Report No.: S0774101
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440


Test Report ------------------------------------------------------------------------------ 4/6



D. Measurement Result


  (1) Frequency: 794.900 MHz

       The maximum field measured is 1.46 dBm


       FI ( Volt ) = 1098.837/20 X 10-6 = 0.087468 V
       FI ( mW ) = (0.087468 X 3 )2/ 49.2 = 1.3995 mW




  Angle of         Spectrum       Corrected     Actually         E. R. P.          Average
 Turn Table         Reading                      Value
    ( °)             (dBm)          (dB)         (dBm)            (mW)               (mW)
              0°          -5.24        -5.25           0.01              1.002
            45°           -6.01        -5.25           -0.76             0.839
            90°           -4.33        -5.25           0.92              1.236
           135°           -4.61        -5.25           0.64              1.158       0.9769
           180°           -5.11        -5.25           0.14              1.032
           225°          -20.51        -5.25         -15.26              0.029
           270°           -3.54        -5.25           1.71              1.482
           315°           -5.41        -5.25           -0.16             1.037




Report No.: S0774101
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440


Test Report ------------------------------------------------------------------------------ 5/6



 (2) Frequency: 800.200 MHz

      The maximum field measured is 0.82dBm
      FI ( Volt ) = 1098.197/20 X 10-6 = 0.0812549 V
      FI ( mW ) = (0.0812549 X 3 )2/ 49.2 = 1.2077 mW




  Angle of         Spectrum       Corrected     Actually         E. R. P.          Average
 Turn Table         Reading                      Value
    ( °)             (dBm)          (dB)         (dBm)            (mW)               (mW)
              0°          -6.51        -5.25           -1.26             0.748
            45°           -8.87        -5.25           -3.62             0.435
            90°           -8.10        -5.25           -2.85             0.519
           135°           -5.29        -5.25           -0.04             0.991       0.681
           180°           -5.35        -5.25           -0.10             0.977
           225°          -13.64        -5.25           -8.39             0.145
           270°           -5.14        -5.25           0.11              1.026
           315°           -7.44        -5.25           -2.19             0.604




Report No.: S0774101
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440


Test Report ------------------------------------------------------------------------------ 6/6



 (3) Frequency: 804.900 MHz

      The maximum field measured is 3.32 dBm
      FI ( Volt ) = 10100.697/20 X 10-6 = 0.108355V
      FI ( mW ) = (0.108355 X 3 )2/ 49.2 = 2.14771 mW




  Angle of         Spectrum       Corrected     Actually         E. R. P.          Average
 Turn Table         Reading                      Value
    ( °)             (dBm)          (dB)       (dBμV/m)           (mW)               (mW)
              0°          -4.16        -5.29           1.13              1.297
            45°           -6.76        -5.29           -1.47             0.713
            90°           -4.78        -5.29           0.51              1.245
           135°           -2.21        -5.29           3.08              2.032       1.336
           180°           -5.55        -5.29           -0.26             0.942
           225°           -7.21        -5.29           -1.92             0.643
           270°           -2.27        -5.29           3.03              2.009
           315°           -2.73        -5.29           2.56              1.803




Report No.: S0774101
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440



Document Created: 2019-05-31 06:17:02
Document Modified: 2019-05-31 06:17:02

© 2024 FCC.report