Test Data

FCC ID: H25TAC2001

Test Report

Download: PDF
FCCID_146365

                                                                                      H25TAC2001


                                 Test Data for H25TAC2001
                              MODEL TAC/COM 2001 REPEATER


I.   INFORMATION REQUIRED UNDER PART 2

Para.

2.10033(a)      This Application for Certification is filed on form 731 with all questions answered.
                Confidentiality is being requested for the schematic. An application fee of $495
                and a request for confidentiality fee of $145 has been sent.

2.10033(b)      N/A

2.10033(c)(1)   The full name and address of the applicant and manufacturer for certification is:

                        DTC Communications Inc.
                        75 Northeastern Blvd.
                        Nashua, NH 03062

        (2)     The FCC Identifier of the device is H25TAC2001

        (3)     A copy of the operating instructions is included in the EXHIBITS.

        (4)     Emission: NBFM Voice – Designator: 11K2F3E
                Emissions calculation is included in the EXHIBITS.

        (5)     Frequency Range: 150 –174 MHz

        (6)     Power: 1.7 Watts at 800 mA; 12 VDC (Battery)

        (7)     Maximum Power Rating of 2.0 Watts

        (8)     A linear regulator with an output voltage of 5.0 VDC powers all stages except the
                final amplifier, which is powered with conditioned battery voltage.

        (9)     A tune-up procedure is included in the EXHIBITS.

        (10)    A schematic diagram is included in the EXHIBITS.

        (11)    A drawing and photo of the equipment identification label is included in the
                EXHIBITS.

        (12)    Photographs showing the external and internal construction of the equipment is
                included in the EXHIBITS.

        (13)    N/A

        (14)    Test Data as required by (46)§§(47) 2.1046 through 2.1057, inclusive, is
                measured in accordance with the procedure setout in (48)§ 2.1041.

        (15)    N/A

        (16)    N/A


                                                                                     H25TAC2001


        (17)    N/A


II. TEST DATA

Data required by (46)§§(47) 2.1046 through 2.1057, inclusive, is measured in
Accordance with the procedures setout in (48)§ 2.1041.


RF POWER OUTPUT 2.1046(a), 2.1033(c)(8)

Repeater power output measurements were made at the RF output connector at the TX output
frequency (165.9375 MHz). This test was done with an unmodulated input carrier on the RX
frequency (171.600 MHz) in accordance with §90.205(d) using the setup of Figure 1.




The power output was measured with a Marconi Radio Communications Test Set, Model 2955.

The electrical characteristics of the RF load was 50 + j0 Ohms (50 ohms pure resistive).

The RF power measured was 1.7W at 12.0 VDC. Note that the TAC/COM 2001 repeater has
input and output tuning bandwidths of 200 kHz respectively; power drops off quickly, either side of
the desired band center due to the duplexer filter’s passband.

Thus the sample complies with §90.205(d).


                                                                                      H25TAC2001




                                           Power -vs- Voltage
             2.5




              2




             1.5
  Power (W




              1




             0.5




              0
                   9.5      10.5                    11.5                 12.5                   13.5
                                                Voltage (VDC)




MODULATION CHARACTERISTICS 2.1047(a), 90.211(a)

Spectrum analyzer data is included which shows that the equipment will meet the modulation
requirements under §90.211(a). This transmitter is equipped with an audio low pass filter circuit.

Frequency Response

Measurement data showing the frequency response of the transmitter is tabulated and graphed
below using the setup of FIGURE 1. A reference level signal of 500 Hz deviation (1/3 nominal
deviation) at the frequency of maximum response (1000 Hz) was used. At each test frequency,
the input deviation level was adjusted to maintain the reference output deviation. Note that the
repeater is designed with a flat audio response in the audio passband. In this range, the repeater
does not color the repeated transmitters original pre-emphasis curve. The Boonton 82AD
modulation meter was used to measure FM deviation levels at both input and output frequencies.


                                                  H25TAC2001


TAC/COM 2001
Frequency Response
Deviation = 1/3 nominal (500 Hz)
Frequency Deviation Measurement      Relative
   (Hz)         (Hz)         (dB)   Response
                                      (dB)
      100       120        41.584       -12.395
      200       280        48.943        -5.036
      300       440        52.869        -1.110
      500       500        53.979         0.000
      700       500        53.979         0.000
      900       500        53.979         0.000
     1000       500        53.979         0.000
     1200       500        53.979         0.000
     1400       500        53.979         0.000
     1600       500        53.979         0.000
     1800       500        53.979         0.000
     2000       510        54.151         0.172
     2200       500        53.979         0.000
     2400       490        53.804        -0.175
     2600       480        53.625        -0.354
     2800       460        53.255        -0.724
     3000       430        52.669        -1.310
     3200       380        51.596        -2.383
     3400       340        50.630        -3.349
     3600       290        49.248        -4.731
     3800       240        47.604        -6.375
     4000       200        46.021        -7.958
     4200       160        44.082        -9.897
     4400       140        42.923       -11.056
     4600       130        42.279       -11.700
     4800       120        41.584       -12.395


                                                                      H25TAC2001


                           5000     110            40.828   -13.151
                           5200     100            40.000   -13.979




                                  Frequency Response
                 2.0



                 0.0



                 -2.0



                 -4.0
Response (dB)




                 -6.0



                 -8.0



                -10.0



                -12.0



                -14.0



                -16.0
                     100                    1000                                   10000
                                        Frequency (Hz)


                                                                                    H25TAC2001


Modulation Limiting

Curves showing frequency deviation output on 165.9375 MHz versus frequency deviation input
on 171.600 MHz are shown below, tested at the frequency of maximum deviation (1 kHz). The
repeater’s output connector was connected to the input of the spectrum analyzer via a 30 dB
10Watt attenuator and the HP 778D directional coupler thru-path as shown in FIGURE 1. The
input test signal at 171.600 MHz was introduced via the incident coupling arm of the directional
coupler, producing an input RF level which is 70 dB below the repeaters output level. The
information submitted shows the modulation limiting capability well beyond the range of properly
modulated input signals. A Marconi 2041 RF Signal Generator was used to generate the NBFM
modulated input signal and a Boonton 82AD modulation meter was used to measure FM
deviation levels at both input and output frequencies.

              TAC/COM 2001 FCC
              Testing
              Input Deviation -vs- Output Deviation
              Test Tone frequency = 1.0 kHz
                  Input            Output deviation level (Hz)
                deviation
               level (Hz)
                       300       360
                       500       540
                       700       730
                       900       920
                      1000      1010
                      1200      1200
                      1400      1390
                      1600      1580
                      1800      1770
                      2000      1950
                      2200      2150
                      2400      2330
                      2600      2510
                      2800      2630
                      3000      2710
                      3200      2780
                      3400      2810
                      3600      2830
                      3800      2860
                      4000      2870
                      4200      2900
                      4400      2910
                      4600      2920
                      4800      2920


                                                       Input dev. -vs- Output dev.
                        3500
                                                                                                       H25TAC2001


                        3000




                        2500
Output Deviation (Hz)




                        2000




                        1500




                        1000




                         500




                          0
                               0   500   1000   1500       2000          2500            3000   3500   4000   4500   5000
                                                                  Input Deviation (Hz)


                                                                                    H25TAC2001


OCCUPIED BANDWIDTH 2.1049, 90.211(a)

The next series of plots are taken from a Marconi 2383 spectrum analyzer at 169.9375 MHz, the
repeater’s output frequency. The repeater output connector was connected to the input of the
spectrum analyzer via a 30 dB 10Watt attenuator and the HP 778D directional coupler thru-path
as shown in FIGURE 1. The input test signal at 171.600 MHz is introduced via the incident
coupling arm of the directional coupler, producing an input RF level which is 70 dB below the
repeaters output level. The Marconi generator was modulated by its internal audio generator with
a sine wave at 1 kHz and 2.5 kHz at a level 16 dB above that required to produce 50%
modulation (4.73 kHz based on a nominal 1.5 kHz deviation). These represent overmodulated
transmitter signals, which are to be repeated. Audio levels were verified with a Boonton 82AD
Modulation Meter.

Paragraph 90.210(d) states that for transmitters that are designed to operate with a 12.5 kHz
channel bandwidth, any emission must be attenuated below the power (P) of the highest
emission contained within the authorized bandwidth as follows:

        1) 0n any frequency removed from the center of the authorized bandwidth f0 to 5.625
           kHz removed from f0: Zero dB.

        2) 0n any frequency removed from the center of the authorized bandwidth by a
           displacement frequency (fd in kHz) of more than 5.625 kHz but no more than 12.5
           kHz: At least 7.25 (fd – 2.88 kHz) dB.

        3) 0n any frequency removed from the center of the authorized bandwidth by a
           displacement frequency (fd in kHz) of more than 12.5 kHz: At least 50+ log(P) or 70
           dB, whichever is the lesser attenuation.

The authorized bandwidth is 12.5 kHz; the frequency of the sample was set for 165.9375 MHz.

The first plot shows the unmodulated carrier. The second plot shows the modulated carrier. The
mask is superimposed on both spectral plots. All emissions are below the required limits. Thus,
the sample complies with 90.211(a).


                       H25TAC2001


Modulated at 2.5 kHz




Modulated at 1 kHz


                                                                                   H25TAC2001


SPURIOUS EMISSIONS AT ANTENNA TERMINALS 2.1053, 90.209

As required by §§2.1053 and 90.209, Emission Mask D, spurious emissions measurements at the
antenna terminals were made using a Marconi 2383 spectrum analyzer. The repeater test box
was used to directly key the repeater. The leader LAG-12S audio generator was used to provide
the repeater with a 1 kHz modulation signal at a level 16 dB above that required to produce 50%
modulation (4.73 kHz based on a nominal 1.5 kHz deviation). The repeater output connector was
connected to a total of 40 dB of attenuation comprised of 30 dB 10Watt attenuator and a 10 dB
Mini-Circuits CAT-10 attenuator connected to the input of the spectrum analyzer, via a 18-inch
test cable made of RG-58 coax. The additional attenuation was required, in order to maximze the
spectrum analyzers dynamic range.

The spectrum was investigated over the range 9 kHz – 1.75 GHz per §2.1057(a)(1).

All emissions more than 250%, removed from the center of the authorized bandwidth must be
attenuated by at least 50 + 10 log (P) dB below the intentional carrier. Since the maximum
measured unmodulated carrier power was 2 W, this yields a minimum required attenuation of 53
dBc.

All spurious emissions are attenuated below this level.

Thus the sample complies with 2.1053 and 90.209 Emission Mask D.
This plot shows the 165.9375 MHz carrier in a span of 10 MHz – 220 MHz


                                          H25TAC2001




This plot shows a scan from 0 to 2 GHz.


                                                                                     H25TAC2001



FIELD STRENGTH OF SPURIOUS RADIATION 2.1053 and 90.209
(Performed by Retlif Testing Laboratories)


Test Conditions:
                          Exciter Keying Direct Via Test Interface cable
                          Standard temperature and Humidity
                          Battery Power: 12 VDC via Battery
                          Radiation into shielded load.

Test Equipment            See Retlif Test Instruments List

Minimum Standard          §2.1053 The power of any emission shall be attenuated below the carrier
                          power (P) by at least (50 + 10log P) dB or 70 dB, whichever is the lesser
                          attenuation.


Theoretical Calculation of Radiated Power Limit below 1000 MHz

The emissions limit is expressed in terms of equivalent power that would have to be fed into a
dipole antenna in order to produce the same electric field strength.

Based on the maximum rated output power of 0.25W and the formula E = SQRT (30GPt)/R

Where:                    E = Electric Field Intensity in V/m
                          G = Antenna Gain = 1.64
                          Pt = Power in Watts
                          R = Distance from test sample to antenna in Meters = 3


                      E = SQRT (49.2 X 0.25)/3 = 2.02 V/m = 126.10 dBuV/m


Attenuation Requirement: §2.1053 requires that the spurious radiated emissions be attenuated at
least 50 + 10 log (2W) = 53 dB below the unmodulated carrier field strength.

Limit @ 3m = 126.10 – 53 dB = dBuV/m


Theoretical Calculation of radiated Power Limit above 1000 MHz

For all emissions above 1000 MHz, the source of the emission is assumed to be isotropic.
Therefore the antenna gain G = 1 and the limit is reduced slightly to:

Limit @ 3m = 123.97 – 53 dB = dBuV/m


Retlif Laboratories calculated the actual limit to be:

                                           77.37 dBuV/m


                                                                        H25TAC2001


Test Result   Complies. The strongest spurious emission is at the seventh harmonic of
              the 158.030 MHz test frequency with a level of 58.86 dBuV/m @ 3m.
              This is more than 18 dB below the limit.


                                                                                                            corroumomee
                                                                                                             Ieincn mons
                   ®
                       Retlif TestingJg Laboratories
                                z               x                                       z
                                                                                                         "!@*‘~
                                                                                                          sferins.,
                                                                                                            Revnans10 To


                                                                                                            H
                       101 New Boston Road, Goffstown, NH 03045                                           men

                                                                                                           asmeay
                       603—497—4600 — Fax: 603—407—8281                                                    vourkss




                                                          A PACKAGE
                                                            FOR

                                                    Tactical Repeater

                                             Model No. TAC—COM—2001—P
                                                      Serial No. AK418


                            SHOWING COMPLIANCE WITH RADIATED EMISSIONS


                  Customer Name:                    DTC Communications, Inc.

                  Customer P.0.;                    70999

                  Data Package No.:                 R—3749N

                  Packege Date:                     March 14, 2001

                  Test Start Date:                  February 23, 2001

                  Test Finish Date:                 February 28, 2001

                  Test Technician(s):               Tim Firkowski

                  Test Engineer:                    John Monahan

                  Data Prepared By:                 Amanda Leckey

                  Supervisor:                       Scott Wentworth
        O atesniirers ue tb staeraot o csvamec atan ywatrornl and t omannitinto y atere iofi sn oRETLR TESTINGLAdOrATories
        nstrnouplorwicetapnonOalogen qoonloly o e ue tee e reme y rdenirectt le fwpnwonyodater npotcs Terpos
        ant hontberaoce ETTRSTINGTARORATORIRS in h medefe en centreu dsn t recal lc Tistotron ic brepotnt
        noutio ul vita enapomorRei restorotAnomrONES



                                                  Membership Corpeato/indival
sccrtemto i mar              Act. «nosl +sne +iEgE »E1 »NMRTE 2800 +ANST + Rest+ Ti «anga «It$
  €a                                                    miokseone
                                                    A Now Yor Stte Corporaton


TEST SETUP PHOTOGRAPH
  RADIATED EMISSIONS




         RETLIE
        R—3749N
        Radiated
        Emissions




         ro         Retlif Testing Laboratories

              I     DATA PACKAGE No. R—3749N


           DRAWING NO. RCISPR1—RE GENERAL TeST SETUP, TEST METHOD
                             EMISSIONS



Anteiamr




                                          RF TRaNseaRENT ENcLOSURE




                  Tesr avrennia

                                                 Tesr ownte
                                      #



                                                    an

             crowp nuwme
                secomrun
                Anivzen




                           vexsursvent
                           eeument roou
                aue
                mee




                                          ro             Retlif Testing Laboratories

                                            I            DATA PACKAGE No. R—37495N


                                       EQUIPMENT LIST
                                       Radiated Emissions
EN     Type               Manufacturer      Description       Model No.   Cal Date Due Date
az02   Biconilog          EMCO              26 Mitc—2 OB      sle          anomo    anom
ns     BMTTest Receiver   Rohde & Schware   20 He— 26. Citz   Ese          zon      spm




                                                              Retlif Testing Laboratories

                                                              DATA PACKAGE No. R—3749N


                                      RETLIF TESTING LABORATORIES
                                                        TABULAR DATA SHEET
[rost Metho:                [Spurious Raciated Emssions 30 MHz to 1.7 GHz
|customer:                  [DTC GCommunications, nc                             JJob No:      [r—srzon               ]
frost Sampl                 Tactcal Repeater


Model No:                   [Fac.con20012                                        Jsorial No:   [AG13                 ]
fTest Specifiation:         FCC Pan 2 & 90
                                                                                 Paragraph: 2.1053 & 90210
|operating Mode:            [Contnuously Transmiting

[rechnician:                                                                     Date:         2zs01                  ]
Notes:                    Detector Function: Paak      Test Distance= am
                          Harmonic Limit por Emission Mask D oparagraph 90 210
     Tos        Hamone AntPoston‘            Ne         Corecion      Corecied                                  it
  Frequency     Frequency    EuT is         Readno        Facor        Reatig                                ats ht
     ie            wie                       sow           «e          ctuvim                                 coarm
   Tesor
      —            serss          —             —            —              —                                 si40
                   soree          —             .            —              —                                   I
      —            sesoo          —             —            —              —                                   I
                   szosr          —             —            —              —                                   U
      —            sesse          —             —            —              —                                   U
                   terai          —             —            —              —                                   U
      —            merre          —             —            —              —                                   I
      —            19370          —             —            —              —                                   1
      —            Tesore         —             —            —              —                                 saxo




               No EUT emissions were observed twoughout he given hrequency spactrum



[Data Sheet 1 of 1                                                                                           R—3749N


                                                                                     H25TAC2001


Part 15 Spurious Receiver (Unintentional Radiator)

For reference only: All receiver spurs are below the FCC Part 15 , Subpart B, Class B limits.


                                                                                    H25TAC2001


FREQUENCY STABILITY 2.1055, 90.213, 90.214

Frequency stability measurements were made over the temperature range of –30° C to +60° C by
directly keying the exciter with a test interface cable. Variations of the primary DC voltage were
varied by 20 % lower and 10% higher than the rated voltage range (9.6-13.2 VDC) using the
KIKSUI power supply. Frequency measurements were made using a direct (20 dB attenuated)
connection to a Systron Donner model 6420 frequency counter with a frequency accuracy of
better than 0.1 ppm.

Environmental conditions were accomplished with an environmental chamber the Associated
Systems BK-1101.The temperature was first lowered to -30° C and then increased in 10° C
increments. At each temperature, short- term transient effects were monitored and no adverse
effects were noted. The frequency was recorded fifteen seconds after the turn on of the
transmitter. The TAC/COM 2001’s transmitter is well within the 5 ppm limit.


                                                                                    H25TAC2001


The table below shows frequency variations vs. power supply input voltage data.


                           TAC/COM 2001
                            Frequency Stability over voltage
                           Test Frequency (MHz) =     165.9375
                           Voltage Frequency                   Error (ppm)
                           (VDC)     (delta Hz)
                                 9.6         -10      -0.06026
                                 9.8         -10      -0.06026
                                  10         -11      -0.06629
                                10.2         -12      -0.07232
                                10.4         -15       -0.0904
                                10.6         -15       -0.0904
                                10.8         -16      -0.09642
                                  11         -17      -0.10245
                                11.2         -16      -0.09642
                                11.4         -15       -0.0904
                                11.6         -16      -0.09642
                                11.8         -17      -0.10245
                                  12         -17      -0.10245
                                12.2         -18      -0.10847
                                12.4         -19       -0.1145
                                12.6         -20      -0.12053
                                12.8         -20      -0.12053
                                  13         -20      -0.12053
                                13.2         -21      -0.12655


                                         Frequency -vs- voltage
                5


                4


                3


                2


                1
  Error (ppm)




                0


                -1


                -2


                -3


                -4


                -5
                     9.5       10.5                11.5                      12.5   13.5

                                               Voltage (VDC)


                                                                                                               H25TAC2001



                                         The plot below shows the frequency vs. temperature data.

                                                  TAC/COM 2001
                                                         Frequency -vs- Temperature
                                          Test Frequency (MHz) = 165.9375
                                               Temperature        Frequency                 Error (ppm)
                                                (degree C)        delta (Hz)
                                                   -30                       150        0.903955
                                                   -20                       130        0.783427
                                                   -10                        70        0.421846
                                                    0                         50        0.301318
                                                    10                        60        0.361582
                                                    20                        30        0.180791
                                                    30                       -10        -0.06026
                                                    40                      -140        -0.84369
                                                    50                      -220          -1.3258
                                                    60                       -60        -0.36158




                                                             Frequency -vs- Temperature
                        5


                        4


                        3


                        2
Frequency Error (ppm)




                        1


                        0


                        -1


                        -2


                        -3



                        -4


                        -5
                             -40   -30   -20       -10        0        10          20        30     40    50   60   70

                                                                    Tem perature (Deg. C)


                                                                                       H25TAC2001



DTC TEST INSTRUMENTS

Type                    Manufacturer            Model No.
Radio Test Set          Marconi Instruments     2955
RF Signal Generator     Marconi Instuments      2041
Spectrum Analyzer       Marconi Instruments     2383
Deviation Meter         Boonton                 82AD
Multimeter              Hewlett Packard         34401A
DC Power Supply         O.K Industries          PS732
DC Power Supply         KIKSUI                  PAB 18-3-A
Audio Generator         Leader                  LAG-12S
Directional Coupler     Hewlett Packard         778D
Frequency Counter       Systron Donner          6420
RMS Voltmeter           Hewlett Packard         3400A
30 dB 10W Attenuator    Wienchell               33-30-34
10 dB ½ W Attenuator    MiniCircuits            CAT-10
Temperature Chamber     Associated Systems      BK-1101

Repeater Test Interface Box                      DTC –1
(Allows Repeater Exciter to be directly keyed and modulated without an input signal)


                                                                                      H25TAC2001




TRANSIENT FREQUENCY BEHAVIOR 90.214
(Performed by Retlif Testing Laboratories)

The transient frequency behavior test was carried out in accordance with TIA/EIA 603 §2.2.19
method of measurement §3.2.19 standard. This test measures the amount of time required for
the unmodulated higher amplitude test sample to “capture” or “release” a weaker 25 kHz FM
modulated test signal during key-up and key-down. This is an indirect method of measuring the
time that it takes for a transmitter to come on-channel and allows transition effects to be recorded.
The repeater was powered up and down manually with the test interface cable and the power
supply positive terminal. A fast responding diode detector acts as a trigger signal for the
oscilloscope.

 As shown in the oscilloscope plots, three time periods are observed. The t1, t2, t3 mask limits are
superimposed on the data runs. These plots indicate the ton and toff points and the related
frequency displacement. The frequency difference remained within the limits of 90.213 between
t2 and t3. The test sample comes on-frequency smoothly and remains within the limits of the
mask.



                                              BLOCK DIAGRAM

                                      Transient Frequency Behavior 90.214



                            50 Ohm Termination




       Unit                     Directional                                           Modulated
       Under                                                 Combiner                 Signal
                                Coupler
       Test                                                                           Generator




                                                                                       Test
                               RF Detector                  Oscilloscope
                                                                                       Receiver




                                                 Trigger


    TEST SETUP PHOTOGRAPH
TRANSIENTFREQUENCY BEHAVIOR




            r.         Retlif Testing Laboratories

                .      DATA PACKAGE No. R—3749N


                e          prngeprs




          17




                     +                  c                  —              _    x
                 l              .                                   MTO:biis ‘CAT7        ~—£8V 23 Feb 2001
                                                                                                   10:30:36




(cohtotge, Wl   [ore Conmuncators.ne
Tt Sample: ..   |tacica Repoater                                    s
reda Nes i      |tac.com 20012                                      §                —     —            —
Tt MiBad        |FEG Part 90 ev,—TransiontFrequency Beranior (0n)   5           Retlif Testing Laboratories
hNotes:                                                             ,}
                                                                    3      [Report No.   R—3749N
          Daiefazzor Tost[E Fmvowan sneo!                           i
                                            zar>


          Tek Stop: 5.00k5 /s
             ~               P’T H—     mm     enoenonaaitecd
                                                         #p+ j                     _rrg




                     wehromasd                ~4                |                           1
                                                   F

          §EX aaal                                                                      +

             PQL L L d                                 _                                )
                                      L2[——                      _                      4
                                        F


             ‘tri——Tod vian—              i            fitd—biis trrh         1020 23 Feb 200
                                                                                   10:42:07




nmpateeersiene n
rod SEPE racicomeposse
Wilo.    pememl                                                                    m            —
PA 3 es2MR Tsn Frequeney Betae(0)
hNotes:
                                                            @        |__Rellif Testing Laboratories
                                                                [Report No.   R—3740N
          bue [ozror       Toh[Ermoosn Srea[2] o


        Tek Stop: 5.00k5/s




                                                      A_.L
                                                      biris LChTf“"' rfiV“ 23            Feb 2001
                                                                                     10:47:44




Eletnen 4
                                                  m




               DTE Conmncatone, m
Tost Sandles   Tactcal Repeater
Inodel No      ta.com 2009
                                                                  Retlif Testing Laboratories
Tost vatd:     FGC Par 90.213, Frequency Savity
hows.
                                                  8          [Report No.   R—3749N
            oue Gezer Teh{t moase se2l o CJ+


                                                  EQUIPMENT LIST
                                           Transient Frequency Behavior
EN       Type                     Manufacturer            Description      Model No.   Cl Date   Due Date
073.     Inerfhencs Analy         Electo—Metrics          toxtte~ 1 oite   Emcas        souee    sovor
3117..   PowerSopply              B&K Precision           030 ¥de, 30 A    1620         2n3m0    ansion
3233     Grephcs Ploter           Heslet Pockard          Na               za7a         anuoo    anuot
401.     Oscilorcope              Tektronis               wa               Tos s2oa     srnamo   sna:
4004     REMillvolimeter          Boonton Electronics..   10KHe— 12 Gfte   sz           10500    1omer
4910     Tee Adapter              Beuel and Kjaee         10k8e< 1 Gite    oriea        tosto    1oisor
4987     10X Probe                ‘Tckironix              5oo Mz           Petsa        imam     inge
4961     Atemnator                Narda                   pe— 1s oife      mosus        1ommo    rorm
520      Digiul Miltmer           Waverk                  NA               2587         vaad     Team
5308     AM/EM Signal Generator   MarconInste.            1okie~ 12 itz    zom           wsio     Lo




                                                                  e        Retlif Testing Laboratories

                                                                  I        DATA PACKAGE No. R—3749N



Document Created: 2001-04-25 11:59:18
Document Modified: 2001-04-25 11:59:18

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC