Test Report

FCC ID: GX9WTRQ3

Test Report

Download: PDF
FCCID_4468714

        FCC PART 15 SUBPART C TEST REPORT
                                  for
        Emergency Pendant / Wrist Transmitter
                        Model No.: WTRQ3
                      FCC ID: GX9WTRQ3


                                 of
       Applicant: CLIMAX TECHNOLOGY CO., LTD.
Address: No. 258, Sinhu 2nd Rd., Neihu District 114 Taipei City
                        Taiwan (R.O.C.)

                         Tested and Prepared

                                 by

       Worldwide Testing Services (Taiwan) Co., Ltd.
        FCC Registration No.: TW1477, TW0020, TW1072

        Industry Canada filed test laboratory Reg. No. 20037

                     A2LA Accredited No.: 2732.01




                    Report No.: W6M21909-19378-C-1

6F, NO. 58, LANE 188, RUEY-KUANG RD., NEIHU TAIPEI 114, TAIWAN, R.O.C.
TEL: 886-2-66068877      FAX: 886-2-66068879   E-mail: wts@wts-lab.com


 Registration number: W6M21909-19378-C-1
 FCC ID: GX9WTRQ3


TABLE OF CONTENTS

  1     General Information ........................................................................................................................2
  1.1         Notes ...........................................................................................................................................2
  1.2      Testing laboratory .......................................................................................................................3
      1.2.1      Location ..................................................................................................................................3
      1.2.2      Details of accreditation status ................................................................................................3
  1.3         Details of approval holder...........................................................................................................3
  1.4      Application details ......................................................................................................................3
  1.5      Test item .....................................................................................................................................4
  1.6      Test standards .............................................................................................................................4
  2     Technical test ..................................................................................................................................5
  2.1         Summary of test results...............................................................................................................5
  2.2      Test environment ........................................................................................................................5
  2.3         Test equipment utilized ...............................................................................................................6
  2.4      General Test Procedure ...............................................................................................................9
  3     Test results (enclosure) .................................................................................................................10
  3.1         Transmission Requirements ......................................................................................................11
      3.1.1      Limit of Transmission Time ..................................................................................................11
      3.1.2      Active Time ...........................................................................................................................11
  3.2      Output Power (Field Strength) ..................................................................................................12
  3.3         Out of Band Radiated Emissions ..............................................................................................13
  3.4         Transmitter Radiated Emissions in restricted Bands ................................................................14
  3.5         Spurious Emission radiated, Transmitter ..................................................................................15
  3.6         Channel Bandwidth...................................................................................................................17
  3.7         Antenna requirement.................................................................................................................18
  3.8      Duty Cycle ................................................................................................................................19
  3.9         Conducted Measurement at (AC) Power Line ..........................................................................20

Appendix: Photos & Diagrams




Worldwide Testing Services(Taiwan) Co., Ltd                                                                                                  Page 1 of 20


 Registration number: W6M21909-19378-C-1
 FCC ID: GX9WTRQ3
1      General Information


1.1    Notes
The purpose of conformity testing is to increase the probability of adherence to the essential
requirements or conformity specifications, as appropriate.
The complexity of the technical specifications, however, means that full and thorough testing is
impractical for both technical and economic reasons.
Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to
a specification.
Neither is there any guarantee that such a test sample will interwork with other genuinely open systems.
The existence of the tests nevertheless provides the confidence that the test sample possesses the
qualities as maintained and that is performance generally conforms to representative cases of
communications equipment.


The test results of this test report relate exclusively to the item tested as specified in 1.5.
The test report may only be reproduced or published in full.
Reproduction or publication of extracts from the report requires the prior written approval of the
Worldwide Testing Services(Taiwan) Co., Ltd.



Tester:
September 27, 2019                Leon Chueh

Date                  WTS-Lab.        Name                            Signature




Technical responsibility for area of testing:


September 27, 2019                  Kevin Wang

Date                  WTS             Name                            Signature




Worldwide Testing Services(Taiwan) Co., Ltd                                                       Page 2 of 20


 Registration number: W6M21909-19378-C-1
 FCC ID: GX9WTRQ3
1.2    Testing laboratory

1.2.1 Location
OATS
No.5-1, Lishui, Shuang Sing Village,
Wanli Dist., New Taipei City 207,
Taiwan (R.O.C.)
3 meter semi-anechoic chamber
No.35, Aly. 21, Ln. 228, Ankang Rd., Neihu Dist., Taipei City 114, Taiwan (R.O.C.)
TEL:886-2-6613-0228
FAX:886-2-2791-5046

Company
Worldwide Testing Services(Taiwan) Co., Ltd.
6F, NO. 58, LANE 188, RUEY-KUANG RD.
NEIHU, TAIPEI 114, TAIWAN R.O.C.
Tel     : 886-2-66068877
Fax     : 886-2-66068879

1.2.2 Details of accreditation status

Accredited testing laboratory
A2LA accredited number: 2732.01
FCC filed test laboratory Reg. No. TW1477, TW0020, TW1072
Industry Canada filed test laboratory Reg. No. 20037

Test location, where different from Worldwide Testing Services (Taiwan) Co., Ltd. :
Name:                               ./.
Accredited number:                 ./.
Street:                            ./.
Town:                             ./.
Country:                          ./.
Telephone:                        ./.
Fax:                              ./.


1.3    Details of approval holder
Name:                               CLIMAX TECHNOLOGY CO., LTD.
Street:                             No. 258, Sinhu 2nd Rd., Neihu District
Town:                               114 Taipei City
Country:                            Taiwan (R.O.C.)
Telephone:                          +886-2-2794-0001
Fax:                                +886-2-2792-6618

1.4    Application details
Date of receipt of test item:        September 20, 2019
Date of test:                        from September 23, 2019 to September 27, 2019

Worldwide Testing Services(Taiwan) Co., Ltd                                           Page 3 of 20


 Registration number: W6M21909-19378-C-1
 FCC ID: GX9WTRQ3
1.5    Test item
Description of test item:            Emergency Pendant / Wrist Transmitter
Type identification:                 WTRQ3
Brand name:                          ./.
Multi-listing model number:          ./.
Transmitting frequency:              433.82 MHz
Operation mode:                      Simplex
Voltage supply:                      Battery 3Vd.c.(CR2032) PCB Antenna
Antenna type:                        see Annex
Photos:

Manufacturer (if applicable)

Name                                 ./.
Street                                ./.
Town                                  ./.
Country                               ./.
Additional information:              ./.


1.6    Test standards
Technical standard : FCC RULES PART 15 SUBPART C § 15.231 (a) (2018-10)




Worldwide Testing Services(Taiwan) Co., Ltd                                  Page 4 of 20


   Registration number: W6M21909-19378-C-1
   FCC ID: GX9WTRQ3
  2      Technical test
  2.1    Summary of test results

  No deviations from the technical specification(s) were ascertained in the course           
  of the tests performed.

  or

  The deviations were ascertained in the course of the tests performed.                      


  2.2    Test environment
  Relative humidity content:           20 ... 75 %

  Air pressure:                        86 ... 103 kPa

  Details of power supply:             Battery 3Vd.c.(CR2032)


                             Test item Name                                          Uncertainty

                                                                           Expanded Uncertainty:
 Estimation Result of Uncertainty of Conducted Emission                    AMN:1.30 dB
                                                                           Voltage probe:1.36 dB
                                                                           Expanded Uncertainty:
                                                                           0.009-30 MHz:2.02 dB
 Estimation Result of Uncertainty of Radiated Emission(3M)                 30-1000 MHz:3.49 dB
                                                                           1-18 GHz:3.01 dB
                                                                           18-40 GHz:2.43 dB

 Estimation Result of Uncertainty of Bandwidth Measurement
 20 dB Bandwidth, Occupied bandwidth, Channel bandwidth, Expanded Uncertainty:0.45 kHz
 Necessary Bandwidth


 Estimation Result of Uncertainty of Frequency Drift Measurement           Expanded Uncertainty:6.11 Hz
 Frequency stability


 Estimation Result of Uncertainty of Band Edge Measurement                 Expanded Uncertainty:0.98 dBc

The decision rule is: Measurement uncertainty is not taken into account.




  Worldwide Testing Services(Taiwan) Co., Ltd                                                 Page 5 of 20


 Registration number: W6M21909-19378-C-1
 FCC ID: GX9WTRQ3
2.3     Test equipment utilized
                                                                                                             Next Cal.
      No.        Test equipment               Type          Serial No.      Manufacturer    Cal. Date
                                                                                                               Date
ETSTW-CE 001    EMI TEST RECEIVER             ESHS10         842121/013         R&S          2019/6/4          2020/6/3

ETSTW-CE 003    AC POWER SOURCE              APS-9102         D161137            GW                 Function Test
                  ZWEILEITER-V-
ETSTW-CE 004    NETZNACHBILDUNG              ESH3-Z5         840731/011         R&S          2018/11/1        2019/10/31
               TWO-LINE V-NETWORK
                IMPULSBEGRENZER
ETSTW-CE 006                                 ESH3-Z2           100226           R&S          2019/8/16         2020/8/15
                  PULSE LIMITER
                HF-EICHLEITUNG RF
ETSTW-CE 008    STEP ATTENUATOR             334.6010.02      844581/024         R&S                 Function Test
                    139dB DPSP
                 TEMP.&HUMIDITY
ETSTW-CE 009                              GTH-225-40-1P-U   MAA0305-009      GIANT FORCE     2019/7/23         2020/7/22
                     CHAMBER
ETSTW-CE 016   TWO-LINE V-NETWORK             ENV216           100050           R&S          2019/9/16         2020/9/15

ETSTW-CE 028      MXE EMI Receiver            N9038A         MY53220110        Agilent       2019/7/18         2020/7/17

ETSTW-RE 003    EMI TEST RECEIVER             ESI 26         831438/001         R&S          2019/6/4          2020/6/3

ETSTW-RE 004    EMI TEST RECEIVER             ESI 40         832427/004         R&S          2019/5/29         2020/5/28
               TUNABLE BANDREJECT
ETSTW-RE 012                                 D.C 0309            146            K&L                 Function Test
                      FILTER
               TUNABLE BANDREJECT
ETSTW-RE 013                                 D.C 0336            397            K&L                 Function Test
                      FILTER
                 MICROWAVE HORN
ETSTW-RE 018                                  AT4560            27212            AR          2019/7/25         2020/7/24
                     ANTENNA
ETSTW-RE 027     Passive Loop Antenna          6512           00034563       ETS-Lindgren    2019/7/22         2020/7/21
               Double-Ridged Guide Horn
ETSTW-RE 030                                   3117           00035224       ETS-Lindgren    2019/4/2          2020/4/1
                       Antenna
ETSTW-RE 042      Biconical Antenna           HK116            100172           R&S          2019/1/29         2020/1/28
                  Log-Periodic Dipole
ETSTW-RE 043                                  HL223            100166           R&S          2019/4/23         2020/4/22
                       Antenna
ETSTW-RE 044     Log-Periodic Antenna         HL050            100094           R&S          2019/5/13         2020/5/12
                   ESA-E SERIES
ETSTW-RE 045                                  E4404B         MY45111242        Agilent              Pre-test Use
               SPECTRUM ANALYZER
ETSTW-RE 050       Attenuator 10dB          50HF-010-1          None             JFW         2019/2/27         2020/2/26

ETSTW-RE 051        Attenuator 6dB          50HF-006-1          None             JFW         2019/2/27         2020/2/26

ETSTW-RE 053        Attenuator 3dB          50HF-003-1          None             JFW         2019/2/27         2020/2/26

ETSTW-RE 055   SPECTRUM ANALYZER              FSU 26           200074           R&S          2019/3/5          2020/3/4

ETSTW-RE 060       Attenuator 30dB            5015-30        F651012z-01        ATM          2019/2/27         2020/2/26

ETSTW-RE 062       Amplifier Module           CHC 2             None            KMIC         2019/5/16         2020/5/15

ETSTW-RE 064      Bluetooth Test Set       MT8852B-042       6K00005709        Anritsu              Function Test
               Double-Ridged Guide Horn
ETSTW-RE 069                                   3117           00069377       ETS-Lindgren           Function Test
                       Antenna
ETSTW-RE 072    CELL SITE TEST SET            8921A          3339A00375          HP          2019/9/16         2020/9/15
                    SOLID STATE
ETSTW-RE 088                              KMA180265A01          99057           KMIC         2019/9/16         2020/9/15
                     AMPLIFIER
ETSTW-RE 091          Match Pad             MDCS1500            None           WOKEN         2019/5/9          2020/5/8

ETSTW-RE 099          DC Block              50DB-007-1          None             JFW         2019/2/22         2020/2/21

ETSTW-RE 112    AC POWER SOURCE              TFC-1005        T-0A023536        T-Power              Function test
                                                                             MICROWAVE
ETSTW-RE 115      2.4GHz Notch Filter        N0124411          473874                        2019/1/14         2020/1/13
                                                                              CIRCUITS
ETSTW-RE 120          RF Player               MP9200        MP9210-111022      ADIVIC               Function test



Worldwide Testing Services(Taiwan) Co., Ltd                                                               Page 6 of 20


 Registration number: W6M21909-19378-C-1
 FCC ID: GX9WTRQ3
 ETSTW-RE 122      SIGNAL GENERATOR                 SMF100A              102149              R&S             2019/6/3          2020/6/2
                                                    5NSL11-
 ETSTW-RE 125         5GHz Notch filter                                    1            K&L Microwave        2019/8/7          2020/8/6
                                                 5200/E221.3-O/O
                                                    5NSL12-
 ETSTW-RE 126         5GHz Notch filter                                    1            K&L Microwave        2019/8/7          2020/8/6
                                                 5800/E221.3-O/O
 ETSTW-RE 127           RF Switch Box                RFS-01               None               WTS            2019/2/26         2020/2/25

 ETSTW-RE 128        5.3GHz Notch filter            N0153001           SN487233        Microwave Circuits    2019/8/7          2020/8/6

 ETSTW-RE 129        5.5GHz Notch filter            N0555984           SN487234        Microwave Circuits    2019/8/7          2020/8/6
                    Handheld RF Spectrum
 ETSTW-RE 130                                        N9340A          CN0147000204           Agilent                 Pre-test Use
                         Analyzer
 ETSTW-RE 142             Amplifier                   8447D           2805A03378            Agilent         2019/5/16         2020/5/15

 ETSTW-RE 147       Bi-log Hybrid Antenna          MCTD 2786B        BLB16M04005             ETC             2019/4/2          2020/4/1

 ETSTW-RF 002     Electromagnetic field probe         LF-30              K-0007               STT           2019/5/27         2020/5/26

ETSTW-EMI 011      USB Compact Modulator              SFC-U              101689              R&S            2019/5/16         2020/5/15
                      Universal Radio
ETSTW-GSM 002                                       CMU 200              109439              R&S             2019/3/5          2020/3/4
                    Communication Tester
                    Radio Communication
ETSTW-GSM 003                                       MT8820C            6201342073           Anritsu         2019/3/26         2020/3/25
                          Analyzer
                      Wideband Radio
ETSTW-GSM 004                                       CMW500               128092              R&S            2018/10/19        2019/10/18
                    Communication Tester
                                                 WRCTF824/849-
ETSTW-GSM 019         Band Reject Filter                                   3                  WI            2019/1/14         2020/1/13
                                                822/851-40 /12+9SS
                                                 WRCD1747/1748-
ETSTW-GSM 020         Band Reject Filter                                   1                  WI            2019/1/14         2020/1/13
                                                 1743/1752-32/5SS
                                                WRCD1879.5/1880.5
ETSTW-GSM 021         Band Reject Filter          -1875.5/1884.5-          3                  WI            2019/1/14         2020/1/13
                                                      32/5SS
                                                WRCT901.9/903.1-
ETSTW-GSM 022         Band Reject Filter                                   1                  WI            2019/1/14         2020/1/13
                                                   904.25-50/8SS
ETSTW-GSM 023           Power Divider               4901.19.A             None             SUHNER            2019/9/2          2020/9/1
                    Radio Communication
ETSTW-GSM 024                                       MT8821C               None              Anritsu          2019/3/5          2020/3/4
                          Analyzer
ETSTW-GSM 025         Band Reject Filter            BRM19835              001            Micro-Tronics       2019/8/7          2020/8/6

ETSTW-Cable 011     SMA to N type Cable             RGU-400               None            THERMAX                Pre-test Use NCR

ETSTW-Cable 016          BNC Cable                  Switch Box          B Cable 1        Schwarz beck       2019/2/21         2020/2/20

ETSTW-Cable 017          BNC Cable                   X Cable            B Cable 2        Schwarz beck       2019/2/21         2020/2/20

ETSTW-Cable 018          BNC Cable                   Y Cable            B Cable 3        Schwarz beck       2019/2/21         2020/2/20

ETSTW-Cable 019          BNC Cable                   Z Cable            B Cable 4        Schwarz beck       2019/2/21         2020/2/20

ETSTW-Cable 020         N TYPE Cable              OATS Cable 1       N30N30-L335-15M   JYE BAO CO.,LTD.      2019/7/1         2020/6/30

ETSTW-Cable 026       Microwave Cable             SUCOFLEX 104           279075        HUBER+SUHNER         2019/2/25         2020/2/24

ETSTW-Cable 027       Microwave Cable             SUCOFLEX 104           279083        HUBER+SUHNER         2019/5/10          2020/5/9

ETSTW-Cable 028       Microwave Cable            FA147A0015M2020        30064-2            UTIFLEX          2019/9/16         2020/9/15

ETSTW-Cable 029       Microwave Cable            FA147A0015M2020        30064-3            UTIFLEX          2019/9/16         2020/9/15
                                                 SUCOFLEX 104
ETSTW-Cable 030       Microwave Cable                                    279067        HUBER+SUHNER         2019/2/25         2020/2/24
                                                  (S_Cable 9)
ETSTW-Cable 043       Microwave Cable            SUCOFLEX 104            317576        HUBER+SUHNER         2019/5/16         2020/5/15

ETSTW-Cable 058       Microwave Cable            SUCOFLEX 104             none         HUBER+SUHNER          2019/6/6          2020/6/5

ETSTW-Cable 064       Microwave Cable            SUCOFLEX 104           MY28891        HUBER+SUHNER         2019/5/16         2020/5/15

ETSTW-Cable 066        SMA type cable                 32022               None            ASTROLAB          2019/3/15         2020/3/14
                                                EMCCFD400-NM-
ETSTW-Cable 071        N TYPE CABLE                                      170239              EMCI            2019/6/6          2020/6/5
                                                  NM-25000



Worldwide Testing Services(Taiwan) Co., Ltd                                                                               Page 7 of 20


 Registration number: W6M21909-19378-C-1
 FCC ID: GX9WTRQ3
ETSTW-Cable 072    SMA type cable (8m)   SUCOFLEX 104   805800/4   HUBER+SUHNER   2019/5/16         2020/5/15

ETSTW-Cable 074    SMA type cable (2m)   SUCOFLEX 104   802563/4   HUBER+SUHNER   2019/5/16         2020/5/15

WTSTW-SW 002      EMI TEST SOFTWARE        EZ_EMC        None          Farad          Version ETS-03A1

WTSTW-SW 006      EMI TEST SOFTWARE           e3         None         AUDIX            Version 9.161014

WTSTW-SW 008          Signal studio         Agilent      None         AUDIX             Version 2.0.0.1

ETSTW-TH 001        Thermohygrometer        608-H1      45204316       Testo      2019/9/9          2020/9/8

ETSTW-TH 002        Thermohygrometer        608-H1      45204317       Testo      2019/9/9          2020/9/8




Worldwide Testing Services(Taiwan) Co., Ltd                                                    Page 8 of 20


 Registration number: W6M21909-19378-C-1
 FCC ID: GX9WTRQ3
2.4    General Test Procedure

POWER LINE CONDUCTED INTERFERENCE: The procedure used was ANSI STANDARD
C63.10-2013 6.2 using a LISN (if necessary). Both lines were observed. The bandwidth of the spectrum
analyzer was 10 kHz with an appropriate sweep speed.

RADIATION INTERFERENCE: The test procedure used was ANSI STANDARD C63.10-2013 6.3
using a spectrum analyzer. The bandwidth of the spectrum analyzer was 100 kHz with an appropriate
sweep speed. The analyzer was calibrated in dB above a microvolt at the output of the antenna. The
resolution bandwidth was the 100 kHz and the video bandwidth was 300 kHz.

FORMULA OF CONVERSION FACTORS: The Field Strength at 3m was established by adding the
meter reading of the spectrum analyzer (which is set to read in units of dBµV) to the antenna correction
factor supplied by the antenna manufacturer. The antenna correction factors are stated in terms of dB.
Example:
Freq (MHz)       METER READING + ACF + CABLE LOSS (to the receiver) = FS
33               20 dBµV + 10.36 dB/m + 6 dB = 36.36 dBµV/m @3m

ANSI STANDARD C63.10-2013 6.2.2 MEASUREMENT PROCEDURES: The EUT was placed on a
table 80 cm high and with dimensions of 1m by 1.5m (non metallic table). The EUT was placed in the
center of the table. The table used for radiated measurements is capable of continuous rotation. The
spectrum was scanned from 30 MHz to 10th harmonic of the fundamental.
Peak readings were taken in three (3) orthogonal planes and the highest readings.


When an emission was found, the table was rotated to produce the maximum signal strength. At this
point, the antenna was raised and lowered from 1m to 4m. The antenna was placed in both the
horizontal and vertical planes.

ANSI STANDARD C63.10-2009 B.2.7: Any measurements that utilize special test software shall be
indicated and referenced in the test report. During testing, test software ’EZ EMC’ was used for setting
up different operation modes.




Worldwide Testing Services(Taiwan) Co., Ltd                                                Page 9 of 20


 Registration number: W6M21909-19378-C-1
 FCC ID: GX9WTRQ3


3      Test results (enclosure)
             1st test               test after modification                 production test

                                                                               Required    Test       Test
    TEST CASE                                               Para. Number
                                                                                          passed     failed
    Transmission Requirements                              FCC 15.231(a)                            
    Radiated Emission                                      FCC 15.231(b)                            
    Bandwidth of Emission                                  FCC 15.231(c)                            
    Frequency Tolerance                                    FCC 15.231(d)                            
    Period Alternate Field Strength Requirements           FCC 15.231(e)                            
    Antenna Requirement                                         FCC 15.203                          
    Conducted Measurement at (AC) Power Line                    FCC 15.207                          


The following is intentionally left blank.




Worldwide Testing Services(Taiwan) Co., Ltd                                                      Page 10 of 20


 Registration number: W6M21909-19378-C-1
 FCC ID: GX9WTRQ3
3.1     Transmission Requirements
FCC 15.231(a)

3.1.1 Limit of Transmission Time
 According to 15.231(a)(1), a manually operated transmitter shall employ a switch that will automatically
deactivate the transmitter within not more than 5 seconds of being released.

 According to 15.231(a)(2), a transmitter activated automatically shall cease transmission within 5 seconds
after activation.

 According to 15.231(a)(3), periodic transmissions at regular predetermined intervals are not permitted.
However, polling or supervision transmissions, including data, to determine system integrity of
transmitters used in security or safety applications are allowed if the total duration of transmissions does
not exceed more than two seconds per hour for each transmitter. There is no limit on the number of
individual transmissions, provided the total transmission time does not exceed two seconds per hour.

 According to 15.231(a)(4), intentional radiators which are employed for radio control purposes during
emergencies involving fire, security, and safety of life, when activated to signal an alarm, may operate
during the pendency of the alarm condition.

 According to 15.231(a)(5), transmission of set-up information for security systems may exceed the
transmission duration limits in paragraphs (a)(1) and (a)(2) of this section, provided such transmission
are under the control of a professional installer and do not exceed ten seconds after a manually operated
switch is released or a transmitter is activated automatically. Such set-up information may include data.



3.1.2 Active Time
 This manually operated transmitter employs a switch that automatically deactivate the transmitter within
    2.204408818 s of being released.

 This transmitter is operated by automatic activation and active will cease transmission in _____ ms after
activation.

 Others: This product is employed for radio control purpose during emergencies. When emergency switch is
              pulled down, the EUT will transmit a signal around_____ ms and continue to retransmit the signal
              every 5 minutes during the pendency of the alarm condition.

Explanation: See attached diagrams in appendix.

Test equipment used: ETSTW-RE 055, ETSTW-RE 004




Worldwide Testing Services(Taiwan) Co., Ltd                                                         Page 11 of 20


 Registration number: W6M21909-19378-C-1
 FCC ID: GX9WTRQ3
3.2     Output Power (Field Strength)




Limit    15.231(b)

            Fundamental Frequency                   Field strength of fundamental, limit
                    (MHz)                                          µV/m
                40.66 – 40.70                                      2,250
                   70 – 130                                        1,250
                  130 – 174                                    1,250 to 3,750
                  174 – 260                                        3,750
                  260 – 470                                  3,750 to 12,500**
                                              (433.82 MHz: 80.82 dBµV/m = 10992.51 µV/m)
                     Above 470                                     12,500
** linear interpolation

Test equipment used: ETSTW-RE 004, ETSTW-RE 111


Worldwide Testing Services(Taiwan) Co., Ltd                                      Page 12 of 20


 Registration number: W6M21909-19378-C-1
 FCC ID: GX9WTRQ3
3.3    Out of Band Radiated Emissions
FCC Rule: 15.231(b) , 15.35
For out of band emissions that are close to or that exceed the 20 dB attenuation requirement
described in the specification, radiated measurements were performed at a 3 m separation distance
to determine whether these emissions complied with the general radiated emission requirement.

Guidance on Measurement of pulsed emission: 15.35(c)
“the measurement field strength shall be determined by averaging over one complete pulse train,
including blanking intervals, as long as the pulse train does not exceed 0.1 seconds. As an alternative
(provided the transmitter operates for longer than 0.1 seconds) or in cases where the pulse train exceeds
0.1 seconds, the measured field strength shall be determined from the average absolute voltage during a
0.1 second interval during which the field strength is at its maximum value.”

Duty Cycle correction = 20 log (dwell time/100ms or one period)

Limits:
For frequencies (Average measurements)
Correction factor conform 15.35 (c) (Average measurements)
Duty cycle correction :
Max. Peak reading – duty cycle correction

Max permitted average Limits = Max permitted Fundamental limit – 20 dB

For example for 433.82 fundamental carrier:
Max permitted average Limit: 80.82 dBµV/m - 20 dB= 60.82 dBµV/m

For frequencies above 1GHz (Peak measurements).
Modified Limits for peak conform 15.35 (b) = Max Permitted average Limits + 20dB (because Peak
detector is used)




Explanation: See attached diagrams in appendix.

Test equipment used: ETSTW-RE 004, ETSTW-RE 030, ETSTW-RE 111




Worldwide Testing Services(Taiwan) Co., Ltd                                                 Page 13 of 20


 Registration number: W6M21909-19378-C-1
 FCC ID: GX9WTRQ3
3.4     Transmitter Radiated Emissions in restricted Bands
FCC Rules: 15.231 (b), 15.205, 15.209, 15.35
Radiated emission measurements were performed from 30 MHz to 8000 MHz.
For radiated emission tests, the analyzer setting was as followings:
RES BW VID BW
Frequency <1 GHz 100 kHz 100 kHz (Peak measurements)
Frequency >1 GHz 1 MHz 1 MHz (Peak measurements)
1 MHz 1 MHz (Average measurements)
Limits:
For frequencies below 1GHz :

      Frequency of Emission                Field strength                    Field Strength
             (MHz)                       (microvolts/meter)               (dB microvolts/meter)
             30 – 88                             100                               40.0
            88 – 216                             150                               43.5
           216 – 960                             200                               46.0
           Above 960                             500                               54.0


For frequencies above 1GHz (Average measurements).
Guidance on Measurement of pulsed emission:
“If the emission is pulsed, modify the unit for continues operation , use the settings shown above,
then correct the reading by subtracting the peak-average correction factor, derived from the
appropriate duty cycle calculation.

For frequencies above 1GHz (Average measurements).


The correction factor, based on the channel dwell tine in a 100 ms period, may be mathematically
applied to a measurement made with an average detector, to further reduce the value.


Duty cycle correction = 20 log (dwell time/100ms)
No duty cycle correction was added to the reading

Modified Limits for peak conform 15.35 (b) = Max Permitted average Limits + 20dB (because Peak
detector is used)

Above 960 MHz
For mode DSSS CW: 54 dBµV/m + 20 dB = 74 dBµV/m
Explanation: See attached diagrams in appendix.




Worldwide Testing Services(Taiwan) Co., Ltd                                                  Page 14 of 20


 Registration number: W6M21909-19378-C-1
 FCC ID: GX9WTRQ3
3.5     Spurious Emission radiated, Transmitter
Spurious emission was measured with modulation (declared by manufacturer).

The limits on the field strength of the spurious emission in the table § 15.231(b) are based on the
fundamental frequency of the intentional radiator. Spurious emission shall be attenuated to the average
(or alternatively, CISPR quasi-peak) limits shown in this table or to the general limits shown in §
15.209, whichever limit permits a higher field strength.
In addition, radiated emission which fall in the restricted bands, as defined in § 15.205(a), must also
comply with the radiated emission limits specified in § 15.209(a) (See § 15.205(c)).
SAMPLE CALCULATION OF LIMIT. All results will be updated by an automatic measuring system
in accordance to point 2.3.

Calculation of test results:
Such factors like antenna correction, cable loss, external attenuation etc. are already included in the
provided measurement results. This is done by using validated test software and calibrated test system
according the accreditation requirements.
The peak and average spurious emission plots was measured with the average limits.
In the Table being listed the critical peak and average value an exhibit the compliance with the above
calculated Limits.
Summary table with radiated data of the test plots

  Model:                 WTRQ3                  Date:                  --
  Mode:                    --                   Temperature:      --        °C        Engineer:    --
  Polarization: Horizontal                      Humidity:         --        %
                                                                                       Table      Ant.
      Frequency     Reading            Factor      Result        Limit Margin
                              Detector                                                 Degree     High
        (MHz)       (dBuV)              (dB)     (dBuV/m)      (dBuV/m) (dB)
                                                                                       (Deg.)     (cm)
         --           --         --      --          --           --             --       --       --
         --           --         --      --          --           --             --       --       --
         --           --         --      --          --           --             --       --       --
         --           --         --      --          --           --             --       --       --


        Frequency    Reading    Factor    Result @3m Limit @3m Margin Table Ant. High
                     (dBuV)      (dB)      (dBuV/m)  (dBuV/m)         Degree  (cm)
          (MHz)       Peak   Corr.   Duty  Peak Ave. Peak Ave. (dB) (Deg.)
            --          --    --       --   --    --  --    --   --     --      --
            --          --    --       --   --    --  --    --   --     --      --
            --          --    --       --   --    --  --    --   --     --      --
            --          --    --       --   --    --  --    --   --     --      --




Worldwide Testing Services(Taiwan) Co., Ltd                                                       Page 15 of 20


 Registration number: W6M21909-19378-C-1
 FCC ID: GX9WTRQ3
     Polarization: Vertical
                                                                              Table                Ant.
       Frequency     Reading          Factor        Result       Limit Margin
                             Detector                                         Degree               High
         (MHz)       (dBuV)            (dB)       (dBuV/m)     (dBuV/m) (dB)
                                                                              (Deg.)               (cm)
             --         --        --       --         --           --        --       --            --
             --         --        --       --         --           --        --       --            --
             --         --        --       --         --           --        --       --            --
             --         --        --       --         --           --        --       --            --


        Frequency Reading    Factor    Result @3m Limit @3m Margin Table Ant. High
                  (dBuV)      (dB)      (dBuV/m)  (dBuV/m)         Degree  (cm)
          (MHz)    Peak   Corr.   Duty Peak Ave. Peak Ave. (dB) (Deg.)
            --       --    --      --    --    --  --    --   --     --      --
            --       --    --      --    --    --  --    --   --     --      --
            --       --    --      --    --    --  --    --   --     --      --
            --       --    --      --    --    --  --    --   --     --      --

Note
        1.    Correction Factor = Antenna factor + Cable loss - Preamplifier
        2.    The formula of measured value as: Test Result = Reading + Correction Factor
        3.    Detector function in the form : PK = Peak, QP = Quasi Peak, AV = Average
        4.    All not in the table noted test results are more than 20 dB below the relevant limits.
        5.    See attached diagrams in appendix.



All other not noted test plots do not contain significant test results in relation to the limits
Test results: The unit meet the FCC requirements.


Test equipment used: ETSTW-RE 004, ETSTW-RE 030, ETSTW-RE 062, ETSTW-RE 142,
                         ETSTW-RE 147




Worldwide Testing Services(Taiwan) Co., Ltd                                                            Page 16 of 20


 Registration number: W6M21909-19378-C-1
 FCC ID: GX9WTRQ3
3.6       Channel Bandwidth

Measurement of Necessary Bandwidth (BN)


          Used frequency                    Bandwidth                         Limit
           433.82 MHz                    42.08416334 kHz                  1.08455 MHz


Explanation: The bandwidth fulfills the requirements of FCC § 15.231, see attached diagrams in appendix.


Limits:

The bandwidth of the emission shall be no wider than 0.25% of the center frequency for devices
operating above 70 MHz and below 900 MHz. For devices operating above 900 MHz, the emission
shall be no wider than 0.5% of the center frequency. Bandwidth is determined at the points 20 dB down
from the modulated carrier.




Test equipment used: ETSTW-RE 055, ETSTW-RE 004




Worldwide Testing Services(Taiwan) Co., Ltd                                              Page 17 of 20


 Registration number: W6M21909-19378-C-1
 FCC ID: GX9WTRQ3
3.7    Antenna requirement
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
responsible party shall be used with the device. The use of a permanently attached antenna or of an
antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply
with the provisions of this Section. The manufacturer may design the unit so that a broken antenna can
be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited. This
requirement does not apply to carrier current devices or to devices operated under the provisions of
Sections 15.211, 15.213, 15.217, 15.219, or 15.221. Further, this requirement does not apply to
intentional radiators that must be professionally installed, such as perimeter protection systems and
some field disturbance sensors, or to other intentional radiators which, in accordance with Section
15.31(d), must be measured at the installation site. However, the installer shall be responsible for
ensuring that the proper antenna is employed so that the limits in this Part are not exceeded.




Explanation: This PCB Antenna is integral antenna which passes antenna requirement.




                          The equipment meets the               yes           no
                                requirements                                 




Worldwide Testing Services(Taiwan) Co., Ltd                                                   Page 18 of 20


 Registration number: W6M21909-19378-C-1
 FCC ID: GX9WTRQ3
3.8    Duty Cycle


The correction factor, based on the channel dwell time in a 100ms period, may be mathematically
applied to a measurement made with an average detector, to further reduce the measured value.

Average Reading = Peak Reading (dBuV/m) + Duty Cycle Correction

Duty Cycle Correction = 20 log (Cycle)
In order to determine the Duty Cycle, the EUT is measured as:

                       T period           T on                        Duty Cycle Correction
  Testing Mode                                          Duty Cycle
                         (ms)             (ms)                         20*log(Duty Cycle)
Transmitting Mode        100          17.43486974       0.174348697          -15.17

Explanation: See attached diagrams in appendix.



Test equipment used: ETSTW-RE 055, ETSTW-RE 004




Worldwide Testing Services(Taiwan) Co., Ltd                                           Page 19 of 20


 Registration number: W6M21909-19378-C-1
 FCC ID: GX9WTRQ3
3.9         Conducted Measurement at (AC) Power Line


For an intentional radiator which is designed to be connected to the public utility (AC) power line, the
radio frequency voltage that is conducted back onto the AC line on any frequency or frequencies within
the band 150 kHz to 30 MHz shall not exceed the limits in the table bellows with this provision shall be
based on the measurement of the radio frequency voltage between each power line and ground at the
power terminals.

This measurement was transact first with instrumentation using an average and peak detector and a 10
kHz bandwidth. If the peak detector achieves a calculated level, the measurement is repeated by an
instrumentation using a quasi-peak detector.


                                                                    Level
            Frequency
                                      quasi-peak (dBµV/m)                       average (dBµV/m)

              -- kHz                             --                                      --

Note
       1.   The formula of measured value as: Test Result = Reading + Correction Factor
       2.   The Correction Factor = Cable Loss + LISN Insertion Loss + Pulse Limit Loss
       3.   Detector function in the form : PK = Peak, QP = Quasi Peak, AV = Average
       4.   All not in the table noted test results are more than 20 dB below the relevant limits.
       5.   This test is not required because the EUT is battery-used.


Limits:



              Frequency of Emission (MHz)                             Conducted Limit (dBuV)

                                                                 Quasi Peak                   Average

                          0.15-0.5                                66 to 56                    56 to 46

                            0.5-5                                    56                         46

                            5-30                                     60                         50


Test equipment used: ETSTW-CE 001, ETSTW-CE 016, ETSTW-RE 045




Worldwide Testing Services(Taiwan) Co., Ltd                                                          Page 20 of 20


 Registration number: W6M21909-19378-C-1
 FCC ID: GX9WTRQ3



Appendix
A         Photos

     1. External Photos

     2. Internal Photos

     3. Set Up Photo of Radiated Emission


B         Measurement diagrams

     1.     Active Time

     2.     Bandwidth

     3.     Duty Cycle

     4.     Spurious Emissions radiated




Worldwide Testing Services(Taiwan) Co., Ltd   Appendix Page 1 of 14


 Registration number: W6M21909-19378-C-1
 FCC ID: GX9WTRQ3
Active Time




Bandwidth




Worldwide Testing Services(Taiwan) Co., Ltd   Appendix Page 13 of 14


 Registration number: W6M21909-19378-C-1
 FCC ID: GX9WTRQ3
Duty Cycle




Worldwide Testing Services(Taiwan) Co., Ltd   Appendix Page 14 of 14


                                         Address:6F.,No.58,Ln 188,Ruey Kuang Rd,Neihu,Taipei
                                         Tel:+886-2-6606-8877
                                         Fax:+886-2-6606-8879
                                             Radiated Emission Measurement                       Operator:      Sky
        File :1                             Data :#1                   Date: 9/23/2019           Temperature:19.8 ℃
                                                                       Time: 10:17:49 PM         Humidity:74.9 %




   Site :   Chamber
   Condition : FCC 15.231(433MHz) 30-300(PK)                                       Polarization:          Horizontal
   EUT :      W6M21909-19378                                                       Power :      3 Vd.c.

   M/N:                                                                            Distance:    3m

   Test Mode : TX 433.82MHz
   Note :


          Frequency    Reading   Detector    Corr. factor     Result      Limit    Ant.Pos   Tab.Pos   Margin    Comment
   Mk.                 (dBuV)                  (dB/m)       (dBuV/m)    (dBuV/m)    (cm)      (deg.)    (dB)
            (MHz)

    *      126.3126     29.73     peak         -6.40         23.33       43.50      100       225      -20.17
           256.7133     27.64     peak         -7.63         20.01       46.00      100        10      -25.99




*:Maximum data        x:Over limit   !:over margin


                                         Address:6F.,No.58,Ln 188,Ruey Kuang Rd,Neihu,Taipei
                                         Tel:+886-2-6606-8877
                                         Fax:+886-2-6606-8879
                                             Radiated Emission Measurement                       Operator:      Sky
        File :1                             Data :#2                   Date: 9/23/2019           Temperature:19.8 ℃
                                                                       Time: 10:18:22 PM         Humidity:74.9 %




   Site :   Chamber
   Condition : FCC 15.231(433MHz) 30-300(PK)                                       Polarization:          Vertical
   EUT :      W6M21909-19378                                                       Power :      3 Vd.c.

   M/N:                                                                            Distance:    3m

   Test Mode : TX 433.82MHz
   Note :


          Frequency    Reading   Detector    Corr. factor     Result      Limit    Ant.Pos   Tab.Pos   Margin        Comment
   Mk.                 (dBuV)                  (dB/m)       (dBuV/m)    (dBuV/m)    (cm)      (deg.)    (dB)
            (MHz)

    *      133.8876     27.34     peak         -6.37         20.97       43.50      100        30      -22.53
           244.8095     26.61     peak         -8.29         18.32       46.00      100       190      -27.68




*:Maximum data        x:Over limit   !:over margin


                                         Address:6F.,No.58,Ln 188,Ruey Kuang Rd,Neihu,Taipei
                                         Tel:+886-2-6606-8877
                                         Fax:+886-2-6606-8879
                                             Radiated Emission Measurement                       Operator:      Sky
        File :2                             Data :#1                   Date: 9/23/2019           Temperature:19.8 ℃
                                                                       Time: 10:21:17 PM         Humidity:74.9 %




   Site :   Chamber
   Condition : FCC 15.231(433MHz) 300-1000(PK)                                     Polarization:          Horizontal
   EUT :      W6M21909-19378                                                       Power :      3 Vd.c.

   M/N:                                                                            Distance:    3m

   Test Mode : TX 433.82MHz
   Note :


          Frequency    Reading   Detector    Corr. factor     Result      Limit    Ant.Pos   Tab.Pos   Margin    Comment
   Mk.                 (dBuV)                  (dB/m)       (dBuV/m)    (dBuV/m)    (cm)      (deg.)    (dB)
            (MHz)

           670.3406     28.43     peak         -0.67         27.76       80.80      100       245      -53.04
    *      868.1363     41.28     peak          2.85         44.13       80.80      100       315      -36.67




*:Maximum data        x:Over limit   !:over margin


                                         Address:6F.,No.58,Ln 188,Ruey Kuang Rd,Neihu,Taipei
                                         Tel:+886-2-6606-8877
                                         Fax:+886-2-6606-8879
                                             Radiated Emission Measurement                       Operator:      Sky
        File :2                             Data :#2                   Date: 9/23/2019           Temperature:19.8 ℃
                                                                       Time: 10:22:25 PM         Humidity:74.9 %




   Site :   Chamber
   Condition : FCC 15.231(433MHz) 300-1000(PK)                                     Polarization:          Vertical
   EUT :      W6M21909-19378                                                       Power :      3 Vd.c.

   M/N:                                                                            Distance:    3m

   Test Mode : TX 433.82MHz
   Note :


          Frequency    Reading   Detector    Corr. factor     Result      Limit    Ant.Pos   Tab.Pos   Margin        Comment
   Mk.                 (dBuV)                  (dB/m)       (dBuV/m)    (dBuV/m)    (cm)      (deg.)    (dB)
            (MHz)

           643.6874     27.98     peak         -0.99         26.99       80.80      100        45      -53.81
    *      868.1363     38.36     peak          2.85         41.21       80.80      100       165      -39.59




*:Maximum data        x:Over limit   !:over margin


                                         Address:6F.,No.58,Ln 188,Ruey Kuang Rd,Neihu,Taipei
                                         Tel:+886-2-6606-8877
                                         Fax:+886-2-6606-8879
                                             Radiated Emission Measurement                       Operator:      Sky
        File :3                             Data :#1                   Date: 9/23/2019           Temperature:19.8 ℃
                                                                       Time: 10:41:09 PM         Humidity:74.9 %




   Site :   Chamber
   Condition : FCC 15.231(433MHz) 1000-2000(PK)                                    Polarization:          Horizontal
   EUT :      W6M21909-19378                                                       Power :      3 Vd.c.

   M/N:                                                                            Distance:    3m

   Test Mode : TX 433.82MHz
   Note :


          Frequency    Reading   Detector    Corr. factor     Result      Limit    Ant.Pos   Tab.Pos   Margin    Comment
   Mk.                 (dBuV)                  (dB/m)       (dBuV/m)    (dBuV/m)    (cm)      (deg.)    (dB)
            (MHz)

    *      1300.601     52.75     peak         -8.96         43.79       74.00      150        30      -30.21
           1735.471     50.75     peak         -8.27         42.48       80.80      150       110      -38.32




*:Maximum data        x:Over limit   !:over margin


                                         Address:6F.,No.58,Ln 188,Ruey Kuang Rd,Neihu,Taipei
                                         Tel:+886-2-6606-8877
                                         Fax:+886-2-6606-8879
                                             Radiated Emission Measurement                       Operator:      Sky
        File :3                             Data :#4                   Date: 9/23/2019           Temperature:19.8 ℃
                                                                       Time: 10:42:17 PM         Humidity:74.9 %




   Site :   Chamber
   Condition : FCC 15.231(433MHz) 1000-2000(PK)                                    Polarization:          Vertical
   EUT :      W6M21909-19378                                                       Power :      3 Vd.c.

   M/N:                                                                            Distance:    3m

   Test Mode : TX 433.82MHz
   Note :


          Frequency    Reading   Detector    Corr. factor     Result      Limit    Ant.Pos   Tab.Pos   Margin        Comment
   Mk.                 (dBuV)                  (dB/m)       (dBuV/m)    (dBuV/m)    (cm)      (deg.)    (dB)
            (MHz)

    *      1300.601     54.27     peak         -8.96         45.31       74.00      150        70      -28.69
           1735.471     52.86     peak         -8.27         44.59       80.80      150       255      -36.21




*:Maximum data        x:Over limit   !:over margin


                                         Address:6F.,No.58,Ln 188,Ruey Kuang Rd,Neihu,Taipei
                                         Tel:+886-2-6606-8877
                                         Fax:+886-2-6606-8879
                                             Radiated Emission Measurement                       Operator:      Sky
        File :3                             Data :#2                   Date: 9/23/2019           Temperature:19.8 ℃
                                                                       Time: 10:43:57 PM         Humidity:74.9 %




   Site :   Chamber
   Condition : FCC 15.231(433MHz) 2000-4000(PK)                                    Polarization:          Horizontal
   EUT :      W6M21909-19378                                                       Power :      3 Vd.c.

   M/N:                                                                            Distance:    3m

   Test Mode : TX 433.82MHz
   Note :


          Frequency    Reading   Detector    Corr. factor     Result      Limit    Ant.Pos   Tab.Pos   Margin    Comment
   Mk.                 (dBuV)                  (dB/m)       (dBuV/m)    (dBuV/m)    (cm)      (deg.)    (dB)
            (MHz)

           2168.337     57.43     peak         -7.24         50.19       80.80      150       330      -30.61
    *      3470.942     56.23     peak         -3.73         52.50       80.80      150        5       -28.30




*:Maximum data        x:Over limit   !:over margin


                                         Address:6F.,No.58,Ln 188,Ruey Kuang Rd,Neihu,Taipei
                                         Tel:+886-2-6606-8877
                                         Fax:+886-2-6606-8879
                                             Radiated Emission Measurement                       Operator:      Sky
        File :3                             Data :#5                   Date: 9/23/2019           Temperature:19.8 ℃
                                                                       Time: 10:45:20 PM         Humidity:74.9 %




   Site :   Chamber
   Condition : FCC 15.231(433MHz) 2000-4000(PK)                                    Polarization:          Vertical
   EUT :      W6M21909-19378                                                       Power :      3 Vd.c.

   M/N:                                                                            Distance:    3m

   Test Mode : TX 433.82MHz
   Note :


          Frequency    Reading   Detector    Corr. factor     Result      Limit    Ant.Pos   Tab.Pos   Margin        Comment
   Mk.                 (dBuV)                  (dB/m)       (dBuV/m)    (dBuV/m)    (cm)      (deg.)    (dB)
            (MHz)

           2601.202     54.62     peak         -5.26         49.36       80.80      150        70      -31.44
    *      3038.076     55.54     peak         -4.24         51.30       80.80      150       315      -29.50




*:Maximum data        x:Over limit   !:over margin


                                        Address:6F.,No.58,Ln 188,Ruey Kuang Rd,Neihu,Taipei
                                        Tel:+886-2-6606-8877
                                        Fax:+886-2-6606-8879
                                             Radiated Emission Measurement                       Operator:      Sky
     File :3                                Data :#3                   Date: 9/23/2019           Temperature:19.8 ℃
                                                                       Time: 10:47:08 PM         Humidity:74.9 %




   Site :   Chamber
   Condition : FCC 15.231(433MHz) 4000-8000(PK)                                    Polarization:          Horizontal
   EUT :    W6M21909-19378                                                         Power :      3 Vd.c.

   M/N:                                                                            Distance:    3m

   Test Mode : TX 433.82MHz
   Note :


          Frequency    Reading   Detector    Corr. factor     Result      Limit    Ant.Pos   Tab.Pos   Margin    Comment
   Mk.                 (dBuV)                  (dB/m)       (dBuV/m)    (dBuV/m)    (cm)      (deg.)    (dB)
            (MHz)




*:Maximum data        x:Over limit   !:over margin


                                        Address:6F.,No.58,Ln 188,Ruey Kuang Rd,Neihu,Taipei
                                        Tel:+886-2-6606-8877
                                        Fax:+886-2-6606-8879
                                             Radiated Emission Measurement                       Operator:      Sky
     File :3                                Data :#6                   Date: 9/23/2019           Temperature:19.8 ℃
                                                                       Time: 10:48:18 PM         Humidity:74.9 %




   Site :   Chamber
   Condition : FCC 15.231(433MHz) 4000-8000(PK)                                    Polarization:          Vertical
   EUT :    W6M21909-19378                                                         Power :      3 Vd.c.

   M/N:                                                                            Distance:    3m

   Test Mode : TX 433.82MHz
   Note :


          Frequency    Reading   Detector    Corr. factor     Result      Limit    Ant.Pos   Tab.Pos   Margin        Comment
   Mk.                 (dBuV)                  (dB/m)       (dBuV/m)    (dBuV/m)    (cm)      (deg.)    (dB)
            (MHz)




*:Maximum data        x:Over limit   !:over margin



Document Created: 2019-10-01 11:39:04
Document Modified: 2019-10-01 11:39:04