Applicant’s declaration concerning RF Radiation Exposure


We hereby indicate that the product
Product description: Ambient Light, Humidity and Temperature Sensor
Model No: LMHTx-xxxxx Series (x=0~9, A~Z or blank)


The equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled
environment. The integral antennas used for this transmitter must not be co-located or
operating in conjunction with any other antenna or transmitter within the host device.

A safety statement concerning minimum separation distances from enclosure of the
Product : Ambient Light, Humidity and Temperature Sensor
will be integrated in the user’s manual to provide end-users with transmitter operating
conditions for satisfying RF exposure compliance.

The appropriate information can be drawn from the test report no: W6M21611-16434-C-1
and the accompanying calculations.



Company: Climax Technology Co Ltd
Address: No. 258, Sinhu 2nd Rd., Neihu District Taipei City 114 Taiwan


Date: 2016-11-24


Signature


Registration number: W6M21611-16434-C-1
FCC ID: GX9LMHTZB
3.2       RF Exposure Compliance Requirements

FCC Rule: 15.247(b)(3)

EIRP = max. conducted output power + antenna gain
EIRP = 14.61 dBm + 0.25 dBi
      = 14.86 dBm
Limit: EIRP = +36 dBm            for Antenna gain <6dBi

Test equipment used: ETSTW-RE 055


FCC OET Bulletin 65 Edition 97.01 determines the equations for predicting       RF fields and applicable
limits.
The prediction for power density in the far-field but will over-predict power   density in the near field,
where it could be used for walking a “worst case” or conservative prediction.
                                                    PG
                                              S = ---------
                                                   4πR2
S – Power Density
P – Output power ERP
R – Distance
D – Cable Loss
AG – Antenna Gain
          Item                     Unit                     Value                  Remarks
            P                      mW                        28.91                 Peak value
            D                       dB
           AG                      dBi                       0.25
            G                                               1.0593              Calculated Value
            R                       cm                        20                 Assumed value
            S                    mW/cm2                     0.0061              Calculated value

Limits:
                     Limit for General Population / Uncontrolled Exposure
                    Frequency                                      Power Density
                      (MHz)                                          (mW/cm2)
                  1500 – 100.000                                         1.0




Worldwide Testing Services(Taiwan) Co., Ltd.                                              Page 16 of 29



Document Created: 2016-12-07 09:53:56
Document Modified: 2016-12-07 09:53:56

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC