RF Exposure Info

FCC ID: GX9IRZB

RF Exposure Info

Download: PDF
FCCID_2803980

                         Climax Technology Co Ltd
        No. 258, Sinhu 2nd Rd., Neihu District Taipei City 114 Taiwan




Federal Communications Commission
Authorization and Evaluation Division
Equipment Authorization Branch
7435 Oakland Mills Road
Columbia, MD 21046



Applicant’s declaration concerning RF Radiation Exposure


We hereby indicate that the product
Product description: PIR Motion Sensor
Model No: IRx-xxxxx Series (x=0~9, A~Z or blank)


The equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled
environment. The integral antennas used for this transmitter must not be co-located or
operating in conjunction with any other antenna or transmitter within the host device.

A safety statement concerning minimum separation distances from enclosure of the
Product : PIR Motion Sensor
will be integrated in the user’s manual to provide end-users with transmitter operating
conditions for satisfying RF exposure compliance.

The appropriate information can be drawn from the test report no: W6M21510-15381-C-1
and the accompanying calculations.



Company: Climax Technology Co Ltd
Address: No. 258, Sinhu 2nd Rd., Neihu District Taipei City 114 Taiwan

Date: 2015-10-29


Signature


Registration number: W6M21510-15381-C-1
FCC ID: GX9IRZB
3.2       Equivalent isotropic radiated power
FCC Rule: 15.247(b)(3)

EIRP = max. conducted output power
EIRP = 8.66 dBm
Limit: EIRP = +36 dBm            for Antenna gain <6dBi

Test equipment used: ETSTW-RE 055


3.3       RF Exposure Compliance Requirements

According to KDB447498 10 D01v05:
SAR evaluation, by measurement or numerical simulation, is not required when the corresponding SAR
Exclusion Threshold condition, listed below, is satisfied.

The enclosure of the device provides ≥ 0.5 cm separation from the antenna elements to significant
metal parts of the enclosure to minimize potential perturbations.

Frequency Band: 2405-2475 MHz
Maximum Power fed to Antenna: 7.3451 mW

Separation distances:
Antenna feed center to metal parts of enclosure:                         > 5 mm
Distance prescribed in user manual:                                      > 5 mm

        MHz          5                10               15          20             25                   mm
                                                                                                   SAR Test
        2450         10               19               29          38             48               Exclusion
                                                                                                Threshold (mW)

        MHz          30               35               40          45             50                   mm
                                                                                                   SAR Test
        2450         57               67               77          86             96               Exclusion
                                                                                                Threshold (mW)


 MHz      50   60    70    80    90        100   110   120   130   140     150    160    170     180    190     mm
 2450     96   196   296   396   496       596   696   796   896   996    1096    1196   1296   1396   1496    mW




Worldwide Testing Services(Taiwan) Co., Ltd.                                                                Page 15 of 29



Document Created: 2015-11-05 17:30:56
Document Modified: 2015-11-05 17:30:56

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC