Test Report

FCC ID: GX9FPHUB1

Test Report

Download: PDF
FCCID_3916169

       FCC PART 15 SUBPART C TEST REPORT
                                 for
                        Frontpoint Hub
                     Model No.: FPHUB1
                   FCC ID: GX9FPHUB1


                                  of
        Applicant: CLIMAX    TECHNOLOGY CO., LTD.
         Address: No. 258, Sinhu 2nd Rd., Neihu District
                 Taipei City 114 Taiwan ( R.O.C.)

                        Tested and Prepared

                                  by

        Worldwide Testing Services (Taiwan) Co., Ltd.
         FCC Registration No.: TW1477, TW0020, TW1072

Industry Canada filed test laboratory Reg. No. IC 5679A-1, IC 5107A-1

                    A2LA Accredited No.: 2732.01




                  Report No.: W6R21805-18133-C-1

 6F, NO. 58, LANE 188, RUEY-KUANG RD., NEIHU TAIPEI 114, TAIWAN, R.O.C.
 TEL: 886-2-66068877      FAX: 886-2-66068879   E-mail: wts@wts-lab.com


 Registration number: W6R21805-18133-C-1
 FCC ID: GX9FPHUB1


TABLE OF CONTENTS
  1     GENERAL INFORMATION ..................................................................................................................2
  1.1         NOTES .........................................................................................................................................2
  1.2         TESTING LABORATORY ................................................................................................................3
      1.2.1      Location ..................................................................................................................................3
      1.2.2      Details of accreditation status ................................................................................................3
  1.3      DETAILS OF APPROVAL HOLDER ...................................................................................................3
  1.5         TEST ITEM ....................................................................................................................................4
  1.6      TEST STANDARDS .........................................................................................................................4
  2     TECHNICAL TEST ..............................................................................................................................5
  2.1      SUMMARY OF TEST RESULTS ........................................................................................................5
  2.2      TEST ENVIRONMENT ....................................................................................................................5
  2.3      TEST EQUIPMENT UTILIZED ..........................................................................................................6
  2.4      GENERAL TEST PROCEDURE ........................................................................................................9
  3     TEST RESULTS (ENCLOSURE) ..........................................................................................................10
  3.1      TRANSMISSION REQUIREMENTS .................................................................................................11
      3.1.1      Limit of Transmission Time ..................................................................................................11
      3.1.2      Active Time ...........................................................................................................................11
  3.2         OUTPUT POWER (FIELD STRENGTH) ..........................................................................................12
  3.3         OUT OF BAND RADIATED EMISSIONS .........................................................................................14
  3.4      TRANSMITTER RADIATED EMISSIONS IN RESTRICTED BANDS ....................................................15
  3.5      SPURIOUS EMISSION RADIATED, TRANSMITTER .........................................................................16
  3.6      CHANNEL BANDWIDTH ..............................................................................................................26
  3.7      ANTENNA REQUIREMENT ...........................................................................................................27
  3.8      DUTY CYCLE .............................................................................................................................28
  3.9         CONDUCTED MEASUREMENT AT (AC) POWER LINE ..................................................................29




Worldwide Testing Services(Taiwan) Co., Ltd.                                                                                            Page 1 of 31


 Registration number: W6R21805-18133-C-1
 FCC ID: GX9FPHUB1
1      General Information

1.1             Notes
The purpose of conformity testing is to increase the probability of adherence to the essential
requirements or conformity specifications, as appropriate.
The complexity of the technical specifications, however, means that full and thorough testing is
impractical for both technical and economic reasons.
Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to
a specification.
Neither is there any guarantee that such a test sample will interwork with other genuinely open systems.
The existence of the tests nevertheless provides the confidence that the test sample possesses the
qualities as maintained and that is performance generally conforms to representative cases of
communications equipment.


The test results of this test report relate exclusively to the item tested as specified in 1.5.
The test report may only be reproduced or published in full.
Reproduction or publication of extracts from the report requires the prior written approval of the
Worldwide Testing Services(Taiwan) Co., Ltd.



Tester:
June 13, 2018                  Spencer Yang

Date                  WTS-Lab.        Name                            Signature




Technical responsibility for area of testing:

June 13, 2018                  Kevin Wang

Date                  WTS             Name                            Signature




Worldwide Testing Services(Taiwan) Co., Ltd.                                                      Page 2 of 31


 Registration number: W6R21805-18133-C-1
 FCC ID: GX9FPHUB1
1.2    Testing laboratory

1.2.1 Location
OATS
No.5-1, Lishui, Shuang Sing Village,
Wanli Dist., New Taipei City 207,
Taiwan (R.O.C.)
3 meter semi-anechoic chamber
No.35, Aly. 21, Ln. 228, Ankang Rd., Neihu Dist., Taipei City 114, Taiwan (R.O.C.)
TEL:886-2-6613-0228
FAX:886-2-2791-5046

Company
Worldwide Testing Services(Taiwan) Co., Ltd.
6F, NO. 58, LANE 188, RUEY-KUANG RD.
NEIHU, TAIPEI 114, TAIWAN R.O.C.
Tel     : 886-2-66068877
Fax     : 886-2-66068879

1.2.2 Details of accreditation status
Accredited testing laboratory
A2LA accredited number: 2732.01
FCC filed test laboratory Reg. No. TW1477, TW0020, TW1072
Industry Canada filed test laboratory Reg. No. IC 5679A-1, IC 5107A-1



Test location, where different from Worldwide Testing Services (Taiwan) Co., Ltd. :
Name:                                    ./.
Accredited number:                       ./.
Street:                                  ./.
Town:                                    ./.
Country:                                 ./.
Telephone:                               ./.
Fax:                                     ./.


1.3    Details of approval holder
Name:                                CLIMAX TECHNOLOGY CO., LTD.
Street:                              No. 258, Sinhu 2nd Rd., Neihu District
Town:                                Taipei City 114
Country:                             Taiwan ( R.O.C.)
Telephone:                           +886-2-2794-0001
Fax:                                 +886-2-2792-6618




Worldwide Testing Services(Taiwan) Co., Ltd.                                          Page 3 of 31


 Registration number: W6R21805-18133-C-1
 FCC ID: GX9FPHUB1
1.4    Application details

Date of receipt of test item:        May 29, 2018
Date of test:                        from May 29, 2018 to June 07, 2018


1.5    Test item
Description of test item:            Frontpoint Hub

Type identification:                 FPHUB1

Brand name:                          ./.

Multi-listing model number:          ./

Transmitting frequency:              433.82 MHz

Operation mode:                      Half-duplex

Voltage supply:                      Adapter (I/P: 100-240V~ 50/60Hz, 0.5A; O/P: 12V, 1.5A)
                                     Battery: 7.2V, 2300mAh

(The device is tested under fresh battery condition.)

Highest clock frequency:             433.82 MHz

Antenna type:                        Monopole antenna

Photos:                              see Annex

Manufacturer (if applicable)
Name:                                ./.
Street:                              ./.
Town:                                ./.
Country:                             ./.

Additional information:              ./.

1.6    Test standards
Technical standard : FCC RULES PART 15 SUBPART C § 15.231 (a) (2017-10)




Worldwide Testing Services(Taiwan) Co., Ltd.                                          Page 4 of 31


  Registration number: W6R21805-18133-C-1
  FCC ID: GX9FPHUB1


 2      Technical test
 2.1    Summary of test results


 No deviations from the technical specification(s) were ascertained in the course             
 of the tests performed.
 or
 The deviations as specified in 3 were ascertained in the course of the tests                 
 performed.


 2.2    Test environment
 Relative humidity content:            20 ... 75 %

 Air pressure:                         86 ... 103 kPa


                            Test item Name                                          Uncertainty


Estimation Result of Uncertainty of Conducted Emission                 Expanded Uncertainty:1.54 dB

                                                                       Expanded Uncertainty:
                                                                       0.009-30 MHz:2.17 dB
Estimation Result of Uncertainty of Radiated Emission(3M)
                                                                       30-1000 MHz:3.57 dB
                                                                       1-18 GHz:2.60 dB
                                                                       18-40 GHz:2.58 dB

Estimation Result of Uncertainty of Bandwidth Measurement
20 dB Bandwidth, Occupied bandwidth, Channel bandwidth, Necessary Expanded Uncertainty:0.45 kHz
Bandwidth
Estimation Result of Uncertainty of Frequency Drift Measurement
Frequency stability                                               Expanded Uncertainty:6.09 Hz


Estimation Result of Uncertainty of Band Edge Measurement
                                                                       Expanded Uncertainty:0.98 dBc




 Worldwide Testing Services(Taiwan) Co., Ltd.                                                Page 5 of 31


 Registration number: W6R21805-18133-C-1
 FCC ID: GX9FPHUB1
2.3     Test equipment utilized
                                                                                                            Next Cal.
      No.         Test equipment               Type          Serial No.    Manufacturer    Cal. Date
                                                                                                              Date

 ETSTW-CE 001    EMI TEST RECEIVER             ESHS10         842121/013       R&S          2018/5/30        2019/5/29


 ETSTW-CE 003    AC POWER SOURCE              APS-9102         D161137          GW                 Function Test
                   ZWEILEITER-V-
 ETSTW-CE 004    NETZNACHBILDUNG              ESH3-Z5         840731/011       R&S         2017/10/26        2018/10/25
                TWO-LINE V-NETWORK
                 IMPULSBEGRENZER
 ETSTW-CE 006                                 ESH3-Z2          100226          R&S          2017/8/22         2018/8/21
                   PULSE LIMITER
                 HF-EICHLEITUNG RF
 ETSTW-CE 008    STEP ATTENUATOR             334.6010.02      844581/024       R&S                 Function Test
                     139dB DPSP
                  TEMP.&HUMIDITY
 ETSTW-CE 009                              GTH-225-40-1P-U   MAA0305-009    GIANT FORCE     2017/7/14         2018/7/13
                      CHAMBER
 ETSTW-CE 016   TWO-LINE V-NETWORK             ENV216          100050          R&S          2017/8/31         2018/8/30

 ETSTW-CE 028      MXE EMI Receiver            N9038A        MY53220110       Agilent       2017/7/11        2018/7/10

 ETSTW-RE 003    EMI TEST RECEIVER             ESI 26         831438/001       R&S          2018/5/30        2019/5/29

 ETSTW-RE 004    EMI TEST RECEIVER             ESI 40         832427/004       R&S          2018/5/21        2019/5/20

 ETSTW-RE 005    EMI TEST RECEIVER             ESVS10         843207/020       R&S          2017/8/25        2018/8/24

                TUNABLE BANDREJECT
 ETSTW-RE 012                                 D.C 0309           146           K&L                 Function Test
                       FILTER
                TUNABLE BANDREJECT
 ETSTW-RE 013                                 D.C 0336           397           K&L                 Function Test
                       FILTER
                  MICROWAVE HORN
 ETSTW-RE 018                                  AT4560           27212           AR          2017/7/4          2018/7/3
                      ANTENNA
 ETSTW-RE 027     Passive Loop Antenna          6512          00034563      ETS-Lindgren    2017/7/3          2018/7/2
                Double-Ridged Guide Horn
 ETSTW-RE 030                                   3117          00035224      ETS-Lindgren    2018/3/26         2019/3/25
                        Antenna
 ETSTW-RE 042      Biconical Antenna           HK116           100172          R&S          2018/1/23        2019/1/22
                   Log-Periodic Dipole
 ETSTW-RE 043                                  HL223           100166          R&S          2018/4/13        2019/4/12
                        Antenna
 ETSTW-RE 044     Log-Periodic Antenna         HL050           100094          R&S          2018/4/26         2019/4/25
                    ESA-E SERIES
 ETSTW-RE 045                                  E4404B        MY45111242       Agilent              Pre-test Use
                SPECTRUM ANALYZER
 ETSTW-RE 050       Attenuator 10dB          50HF-010-1         None            JFW         2018/3/1          2019/2/28

 ETSTW-RE 051        Attenuator 6dB          50HF-006-1         None            JFW         2018/3/1          2019/2/28

 ETSTW-RE 053        Attenuator 3dB          50HF-003-1         None            JFW         2018/3/1          2019/2/28

 ETSTW-RE 055   SPECTRUM ANALYZER              FSU 26          200074          R&S          2018/3/6          2019/3/5

 ETSTW-RE 060       Attenuator 30dB            5015-30       F651012z-01       ATM          2018/3/1          2019/2/28

 ETSTW-RE 062       Amplifier Module           CHC 2            None           KMIC         2018/3/30         2019/3/29

 ETSTW-RE 064      Bluetooth Test Set       MT8852B-042      6K00005709       Anritsu              Function Test
                Double-Ridged Guide Horn
 ETSTW-RE 069                                   3117          00069377      ETS-Lindgren           Function Test
                        Antenna
 ETSTW-RE 072    CELL SITE TEST SET            8921A         3339A00375         HP          2017/9/11         2018/9/10
                     SOLID STATE
 ETSTW-RE 088                              KMA180265A01         99057          KMIC         2017/9/19        2018/9/18
                      AMPLIFIER
 ETSTW-RE 091          Match Pad             MDCS1500           None          WOKEN         2018/4/16        2019/4/15

 ETSTW-RE 099          DC Block              50DB-007-1         None            JFW         2018/2/23        2019/2/22




Worldwide Testing Services(Taiwan) Co., Ltd.                                                            Page 6 of 31


 Registration number: W6R21805-18133-C-1
 FCC ID: GX9FPHUB1
 ETSTW-RE 112     AC POWER SOURCE              TFC-1005           T-0A023536           T-Power                Function test
                                                                                    MICROWAVE
 ETSTW-RE 115       2.4GHz Notch Filter        N0124411             473874                             2018/1/15         2019/1/14
                                                                                     CIRCUITS
 ETSTW-RE 120            RF Player              MP9200          MP9210-111022          ADIVIC                 Function test

 ETSTW-RE 122     SIGNAL GENERATOR             SMF100A              102149              R&S            2018/5/29         2019/5/28
                                               5NSL11-
 ETSTW-RE 125        5GHz Notch filter                                1            K&L Microwave        2017/8/9          2018/8/8
                                            5200/E221.3-O/O
                                               5NSL12-
 ETSTW-RE 126        5GHz Notch filter                                1            K&L Microwave        2017/8/9          2018/8/8
                                            5800/E221.3-O/O
 ETSTW-RE 127         RF Switch Box             RFS-01               None               WTS            2018/2/27         2019/2/26

 ETSTW-RE 128       5.3GHz Notch filter        N0153001           SN487233        Microwave Circuits    2017/8/9          2018/8/8

 ETSTW-RE 129       5.5GHz Notch filter        N0555984           SN487234        Microwave Circuits    2017/8/9          2018/8/8
                  Handheld RF Spectrum
 ETSTW-RE 130                                   N9340A          CN0147000204           Agilent                 Pre-test Use
                       Analyzer
 ETSTW-RE 142            Amplifier               8447D           2805A03378            Agilent         2018/3/30         2019/3/29

 ETSTW-RE 147      Bi-log Hybrid Antenna      MCTD 2786B        BLB16M04005             ETC            2018/3/23         2019/3/22

 ETSTW-RE 151       Thermohygrometer             608-h1            45104376            TESTO           2017/8/30         2018/8/29

ETSTW-EMI 011     USB Compact Modulator          SFC-U              101689              R&S            2018/5/10          2019/5/9
                     Universal Radio
ETSTW-GSM 002                                  CMU 200              109439              R&S            2018/2/27         2019/2/26
                   Communication Tester
                   Radio Communication
ETSTW-GSM 003                                  MT8820C            6201342073           Anritsu          2018/3/2          2019/3/1
                         Analyzer
                     Wideband Radio
ETSTW-GSM 004                                  CMW500               128092              R&S            2017/10/16        2018/10/15
                   Communication Tester
                                            WRCTF824/849-
ETSTW-GSM 019        Band Reject Filter                               3                  WI            2018/1/11         2019/1/10
                                           822/851-40 /12+9SS
                                            WRCD1747/1748-
ETSTW-GSM 020        Band Reject Filter                               1                  WI            2018/1/11         2019/1/10
                                            1743/1752-32/5SS
                                           WRCD1879.5/1880.5
ETSTW-GSM 021        Band Reject Filter      -1875.5/1884.5-          3                  WI            2018/1/11         2019/1/10
                                                 32/5SS
                                           WRCT901.9/903.1-
ETSTW-GSM 022        Band Reject Filter                               1                  WI            2018/1/11         2019/1/10
                                              904.25-50/8SS
ETSTW-GSM 023         Power Divider            4901.19.A             None             SUHNER           2017/9/13         2018/9/12
                   Radio Communication
ETSTW-GSM 024                                  MT8821C               None              Anritsu          2018/3/7          2019/3/6
                         Analyzer
ETSTW-Cable 011    SMA to N type Cable         RGU-400               None            THERMAX                Pre-test Use NCR

ETSTW-Cable 016         BNC Cable              Switch Box          B Cable 1        Schwarz beck       2018/2/22         2019/2/21

ETSTW-Cable 017         BNC Cable               X Cable            B Cable 2        Schwarz beck       2018/2/22         2019/2/21

ETSTW-Cable 018         BNC Cable               Y Cable            B Cable 3        Schwarz beck       2018/2/22         2019/2/21

ETSTW-Cable 019         BNC Cable               Z Cable            B Cable 4        Schwarz beck       2018/2/22         2019/2/21

ETSTW-Cable 020       N TYPE Cable           OATS Cable 1       N30N30-L335-15M   JYE BAO CO.,LTD.      2017/7/3          2018/7/2

ETSTW-Cable 026      Microwave Cable         SUCOFLEX 104           279075        HUBER+SUHNER         2018/2/27         2019/2/26

ETSTW-Cable 027      Microwave Cable         SUCOFLEX 104           279083        HUBER+SUHNER          2018/5/9          2019/5/8

ETSTW-Cable 028      Microwave Cable        FA147A0015M2020        30064-2            UTIFLEX           2017/9/7          2018/9/6

ETSTW-Cable 029      Microwave Cable        FA147A0015M2020        30064-3            UTIFLEX           2017/9/7          2018/9/6
                                            SUCOFLEX 104
ETSTW-Cable 030      Microwave Cable                                279067        HUBER+SUHNER         2018/2/27         2019/2/26
                                             (S_Cable 9)
                                            SUCOFLEX 104
ETSTW-Cable 031      Microwave Cable                                238092        HUBER+SUHNER         2018/3/30         2019/3/29
                                            (S_Cable 10)
ETSTW-Cable 043      Microwave Cable        SUCOFLEX 104            317576        HUBER+SUHNER         2018/3/30         2019/3/29

ETSTW-Cable 048      Microwave Cable        SUCOFLEX 104            325519        HUBER+SUHNER         2018/3/30         2019/3/29




Worldwide Testing Services(Taiwan) Co., Ltd.                                                                        Page 7 of 31


 Registration number: W6R21805-18133-C-1
 FCC ID: GX9FPHUB1
ETSTW-Cable 058     Microwave Cable   SUCOFLEX 104     none     HUBER+SUHNER   2018/2/21         2019/2/20

ETSTW-Cable 064     Microwave Cable   SUCOFLEX 104    MY28891   HUBER+SUHNER   2018/3/30         2019/3/29

ETSTW-Cable 066      SMA type cable       32022        None       ASTROLAB     2017/8/31         2018/8/30
                                      EMCCFD400-NM-
ETSTW-Cable 071     N TYPE CABLE                      170239        EMCI       2018/2/21         2019/2/20
                                        NM-25000
WTSTW-SW 002      EMI TEST SOFTWARE      EZ_EMC        None         Farad          Version ETS-03A1

WTSTW-SW 006      EMI TEST SOFTWARE         e3         None        AUDIX            Version 9.161014

WTSTW-SW 008          Signal studio       Agilent      None        AUDIX             Version 2.0.0.1




Worldwide Testing Services(Taiwan) Co., Ltd.                                               Page 8 of 31


 Registration number: W6R21805-18133-C-1
 FCC ID: GX9FPHUB1
2.4    General Test Procedure

POWER LINE CONDUCTED INTERFERENCE: The procedure used was ANSI STANDARD
C63.10-2013 6.2 using a LISN (if necessary). Both lines were observed. The bandwidth of the spectrum
analyzer was 10 kHz with an appropriate sweep speed.

RADIATION INTERFERENCE: The test procedure used was ANSI STANDARD C63.10-2013 6.3
using a spectrum analyzer. The bandwidth of the spectrum analyzer was 100 kHz with an appropriate
sweep speed. The analyzer was calibrated in dB above a microvolt at the output of the antenna. The
resolution bandwidth was the 100 kHz and the video bandwidth was 300 kHz.

FORMULA OF CONVERSION FACTORS: The Field Strength at 3m was established by adding the
meter reading of the spectrum analyzer (which is set to read in units of dBµV) to the antenna correction
factor supplied by the antenna manufacturer. The antenna correction factors are stated in terms of dB.
Example:
Freq (MHz)       METER READING + ACF + CABLE LOSS (to the receiver) = FS
33               20 dBµV + 10.36 dB/m + 6 dB = 36.36 dBµV/m @3m

ANSI STANDARD C63.10-2013 6.2.2 MEASUREMENT PROCEDURES: The EUT was placed on a
table 80 cm high and with dimensions of 1m by 1.5m (non metallic table). The EUT was placed in the
center of the table. The table used for radiated measurements is capable of continuous rotation. The
spectrum was scanned from 30 MHz to 10th harmonic of the fundamental.
Peak readings were taken in three (3) orthogonal planes and the highest readings.

When an emission was found, the table was rotated to produce the maximum signal strength. At this
point, the antenna was raised and lowered from 1m to 4m. The antenna was placed in both the
horizontal and vertical planes.

ANSI STANDARD C63.10-2013 B.2.7: Any measurements that utilize special test software shall be
indicated and referenced in the test report. During testing, test software ’EZ EMC’ was used for setting
up different operation modes.




Worldwide Testing Services(Taiwan) Co., Ltd.                                             Page 9 of 31


 Registration number: W6R21805-18133-C-1
 FCC ID: GX9FPHUB1
3      Test results (enclosure)
             1st test               test after modification                 production test

                                                                               Required    Test     Test
    TEST CASE                                               Para. Number
                                                                                          passed   failed
    Transmission Requirements                              FCC 15.231(a)                          
    Radiated Emission                                      FCC 15.231(b)                          
    Bandwidth of Emission                                  FCC 15.231(c)                          
    Frequency Tolerance                                    FCC 15.231(d)                          
    Period Alternate Field Strength Requirements           FCC 15.231(e)                          
    Antenna Requirement                                         FCC 15.203                        
    Conducted Measurement at (AC) Power Line                    FCC 15.207                        


The following is intentionally left blank.




Worldwide Testing Services(Taiwan) Co., Ltd.                                                 Page 10 of 31


 Registration number: W6R21805-18133-C-1
 FCC ID: GX9FPHUB1
3.1     Transmission Requirements
FCC 15.231(a)

3.1.1 Limit of Transmission Time
 According to 15.231(a)(1), a manually operated transmitter shall employ a switch that will automatically
deactivate the transmitter within not more than 5 seconds of being released.

 According to 15.231(a)(2), a transmitter activated automatically shall cease transmission within 5 seconds
after activation.

3.1.2 Active Time
 This manually operated transmitter employs a switch that automatically deactivate the transmitter within
340.681363 ms of being released.

 This transmitter is operated by automatic activation and active will cease transmission in   ms after
activation..




Test equipment used : ETSTW-RE 004




Worldwide Testing Services(Taiwan) Co., Ltd.                                                      Page 11 of 31


 Registration number: W6R21805-18133-C-1
 FCC ID: GX9FPHUB1
3.2    Output Power (Field Strength)




Worldwide Testing Services(Taiwan) Co., Ltd.   Page 12 of 31


 Registration number: W6R21805-18133-C-1
 FCC ID: GX9FPHUB1




Limit    15.231(b)

             Fundamental Frequency                   Field strength of fundamental, limit
                     (MHz)                                          µV/m
                 40.66 – 40.70                                       2,250
                    70 – 130                                         1,250
                   130 – 174                                    1,250 to 3,750
                   174 – 260                                         3,750
                   260 – 470                                  3,750 to 12,500**
                                               (433.82 MHz: 80.82 dBµV/m = 10992.51 µV/m)
                     Above 470                                      12,500

** linear interpolation

Test equipment used: ETSTW-RE 004, ETSTW-RE 062, ETSTW-RE 142, ETSTW-RE 147

Worldwide Testing Services(Taiwan) Co., Ltd.                                    Page 13 of 31


 Registration number: W6R21805-18133-C-1
 FCC ID: GX9FPHUB1


3.3    Out of Band Radiated Emissions
FCC Rule: 15.231(b) , 15.35
For out of band emissions that are close to or that exceed the 20 dB attenuation requirement
described in the specification, radiated measurements were performed at a 3 m separation distance
to determine whether these emissions complied with the general radiated emission requirement.

Guidance on Measurement of pulsed emission: 15.35(c)
“the measurement field strength shall be determined by averaging over one complete pulse train,
including blanking intervals, as long as the pulse train does not exceed 0.1 seconds. As an alternative
(provided the transmitter operates for longer than 0.1 seconds) or in cases where the pulse train exceeds
0.1 seconds, the measured field strength shall be determined from the average absolute voltage during a
0.1 second interval during which the field strength is at its maximum value.”

Duty Cycle correction = 20 log (dwell time/100ms or one period)

Limits:
For frequencies (Average measurements)
Correction factor conform 15.35 (c) (Average measurements)
Duty cycle correction :
Max. Peak reading – duty cycle correction

Max permitted average Limits = Max permitted Fundamental limit – 20 dB

For example for 433.82 fundamental carrier:
Max permitted average Limit: 80.82 dBµV/m - 20 dB= 60.82 dBµV/m

For frequencies above 1GHz (Peak measurements).
Modified Limits for peak conform 15.35 (b) = Max Permitted average Limits + 20dB (because Peak
detector is used)




Worldwide Testing Services(Taiwan) Co., Ltd.                                              Page 14 of 31


 Registration number: W6R21805-18133-C-1
 FCC ID: GX9FPHUB1

3.4     Transmitter Radiated Emissions in restricted Bands
FCC Rules: 15.231 (b), 15.205, 15.209, 15.35
Radiated emission measurements were performed from 30 MHz to 8000 MHz.
For radiated emission tests, the analyzer setting was as followings:
RES BW VID BW
Frequency <1 GHz 100 kHz 100 kHz (Peak measurements)
Frequency >1 GHz 1 MHz 1 MHz (Peak measurements)
1 MHz 1 MHz (Average measurements)
Limits:

For frequencies below 1GHz :


      Frequency of Emission                Field strength                    Field Strength
             (MHz)                       (microvolts/meter)               (dB microvolts/meter)
             30 – 88                             100                               40.0
            88 – 216                             150                               43.5
           216 – 960                             200                               46.0
           Above 960                             500                               54.0


For frequencies above 1GHz (Average measurements).
Guidance on Measurement of pulsed emission:
“If the emission is pulsed, modify the unit for continues operation , use the settings shown above,
then correct the reading by subtracting the peak-average correction factor, derived from the
appropriate duty cycle calculation.

For frequencies above 1GHz (Average measurements).


The correction factor, based on the channel dwell tine in a 100 ms period, may be mathematically
applied to a measurement made with an average detector, to further reduce the value.


Duty cycle correction = 20 log (dwell time/100ms)
No duty cycle correction was added to the reading

Modified Limits for peak conform 15.35 (b) = Max Permitted average Limits + 20dB (because Peak
detector is used)

Above 960 MHz
For mode DSSS CW: 54 dBµV/m + 20 dB = 74 dBµV/m




Worldwide Testing Services(Taiwan) Co., Ltd.                                               Page 15 of 31


 Registration number: W6R21805-18133-C-1
 FCC ID: GX9FPHUB1
3.5    Spurious Emission radiated, Transmitter
Spurious emission was measured with modulation (declared by manufacturer).

The limits on the field strength of the spurious emission in the table § 15.231(b) are based on the
fundamental frequency of the intentional radiator. Spurious emission shall be attenuated to the average
(or alternatively, CISPR quasi-peak) limits shown in this table or to the general limits shown in §
15.209, whichever limit permits a higher field strength.
In addition, radiated emission which fall in the restricted bands, as defined in § 15.205(a), must also
comply with the radiated emission limits specified in § 15.209(a) (see § 15.205(c)).
SAMPLE CALCULATION OF LIMIT. All results will be updated by an automatic measuring system
in accordance to point 2.3.
Calculation of test results:
Such factors like antenna correction, cable loss, external attenuation etc. are already included in the
provided measurement results. This is done by using validated test software and calibrated test system
according the accreditation requirements.
The peak and average spurious emission plots was measured with the average limits.
In the Table being listed the critical peak and average value an exhibit the compliance with the above
calculated Limits.
Summary table with radiated data of the test plots




Worldwide Testing Services(Taiwan) Co., Ltd.                                            Page 16 of 31


        eMe.
    a             s
a                   o                               e                     e                        e                 e
sWye$. Worldwide Testing Services(Taiwan) Co., Ltd.
w                     0    J


t     $                                                                         ==
 S wart




                                                               Radiated Emission Measurement                                 Operator:             Leon
              File :1                                         Data :#2                          Date: 6/3/2018               Temperature:26.8 °C
             90.0         dBu¥/m                                                                Time: 11:44:51 AM            Humidity:62.1 %
                                                                                                                                             Limit] :      «——
             so                                                                                                                              Limit2:       d



             70

             so

             50

             an                                                    1
                                                                                                                                    2
             30

             n                                                                                                                              Pn
             10

             o
             —10.0
                30.000         57.00       84.00        111.00         138.00          165.00      192.00    219.00         246.00                      300.00   MHz
        Site :            Chamber
        Condition :             FCC 15.231(433MHz) 30—300(PK)                                               Polarization:                 Vertical
        EUT :           W6R21805—18133                                                                      Power :         120 Vac.
        MAN:                                                                                                Distance: 3m
        Test Mode : TX 433.82MHz
        Note :


                  Frequency            Reading     Detector    Corr. factor           Result       Limit    Ant.Pos      |Tab.Pos       Margin          Comment
        Mk.           (MH2)            (dBuy)                    (dBim)              (dBu¥im)    (dBu¥im)     (em)        {deg.)         (dB)
         #          124.6894]          45.46        peak         —6.46                39.00        43.50     100           172          4.50
                    250.2204|          4110         peak         —7.36                33.74        46.00     100           96           |—12.26


     eMe.
¢a             s
                 %3    4            f            —                      6                      6
sWye$. Worldwide Testing Services(Taiwan) Co., Ltd.
%                &                                                          ==
 Cugom®



                                                             Radiated Emission Measurement                            Operator:               Leon
           File :2                                          Data :#1                        Date: 6/3/2018            Temperature:26.8 °C
          90.0        dBu¥/m                                                                Time: 4:33:21 AM          Humidity:62.1 %
                                                                                                                                   Limit] :          «——
          so                                                                                                                       Limit2:           ——



          70

          so

          50

          a0
                                                        1
          30

                 WW                          e
          20

          10

          o
          —10.0
             300.000       370.00       440.00       510.00        580.00          650.00      720.00    790.00      860.00                    1000.00 MHz
     Site :           Chamber
     Condition :             FCC 15.231(433MHz) 300—1000(PK)                                            Polarization:           Horizontal
     EUT :           W6R21805—18133                                                                     Power :      120 Vac.
     MAN:                                                                                               Distance: 3m
     Test Mode : TX 433.82MHz
     Note :


               Frequency        Reading      Detector        Corr. factor         Result       Limit    Ant.Pos   |Tab.Pos    Margin           Comment
     Mk.           (MH2)            (dBuy)                     (dBim)            (dBu¥im)    (dBu¥im)     (em)     {deg.)      (dB)
                 499.1983)|         33.69        peak          —2.23              3146         80.80     100        245       |—49.34
      #          868.1363)          32.80        peak           4.25              37.05        80.80     100        356       |43.75


        eMe.
    a             s
a                   o                                e                        e                      e                 e
sWye$. Worldwide Testing Services(Taiwan) Co., Ltd.
w                     0    J


%                   &                                                             ==
    Cugom®



                                                                   Radiated Emission Measurement                               Operator:               Leon
              File :2                                             Data :#2                        Date: 6/3/2018               Temperature:26.8 °C
             90.0         dBu¥/m                                                                  Time: 4:37:06 AM             Humidity:62.1 %
                                                                                                                                            Limit] :          «——
             so                                                                                                                             Limit2:           ——



             70

             so

             50

             a0
             30                                               1                                                                         WW»!W‘-'\-’W
                                                                                            MWMM
                                                         en
             20

             10

             o
             —10.0
                300.000        370.00       440.00        510.00         580.00          650.00      720.00    790.00         860.00                    1000.00 MHz
        Site :            Chamber
        Condition :              FCC 15.231(433MHz) 300—1000(PK)                                              Polarization:              Vertical
        EUT :           W6R21805—18133                                                                        Power :         120 Vac.
        MAN:                                                                                                  Distance: 3m
        Test Mode : TX 433.82MHz
        Note :


                  Frequency         Reading      Detector          Corr. factor         Result       Limit    Ant.Pos      |Tab.Pos    Margin           Comment
        Mk.           (MH2)             (dBuy)                       (dBim)            (dBu¥im)    (dBu¥im)     (em)        {deg.)      (dB)
                    499.1983)           31.68        peak            —2.23              2945         80.80     100           80        |—51.35
         #          597.3948|           33.13        peak            ~1.06              32.07        80.80     100           275       |—48.73


A
  x _eMc._,sC
&
<
6 WS@ Worldwide Testing Services(Taiwan) Co., Ltd.
 L          &
    Ayom®




                                                        Radiated Emission Measurement                                  Operator:       Leon
          File :3                                   Data :#1                           Date: 6/3/2018                 Temperature:26.8 °C
          90.0      dBu¥/m                                                             Time: 6:49:37 AM                Humidity:62.1 %
                                                                                                                                  Limit1:      —
          so                                                                                                                      Limit2:       =

                                              1                       j                           TL         C
          70

          so
                                              1                       1                           TN         OO
          50

          40
                                                    1                                                            2
          30

          20

          10

          0
          10.0
             1000.000 1100.00       1200.00   1300.00         1400.00        1500.00      1600.00      1700.00        1800.00               2000.00   MHz
    Site :          Chamber
    Condition :            FCC15.231(433MHz) 1000—2000(PK)                                          Polarization:               Horizontal
    EUT :         WeR21805—18133                                                                    Power:            120 ¥a¢.
    MAN:                                                                                            Distance: 9m
    Test Mode : TX 433.92MHz
    Note :


    ny.        Frequency     Reading     Detector       Cor. factor         Result         Limit  Ant.Ros |Tab.Pos Margin                   Comment
          f      (MHz)        (dBuy)                      (dB/im)         (dBu¥/im)      (dBu¥/m)   (em)   (deg.)   (d8)
     *           1301.400|    42.94       peak            —9.00            33.94          74.00        150           245    |40.06
                 1735.200|      41.51     peak            —7.09            34.42          80.80        150           90     |46.38


A
  x _eMc._,sC
&
<
6 WS@ Worldwide Testing Services(Taiwan) Co., Ltd.
 L          &
    Ayom®




                                                      Radiated Emission Measurement                                  Operator:       Leon
          File :3                                 Data :#4                           Date: 6/3/2018                 Temperature:26.8 °C
          90.0      dBu¥/m                                                           Time: 6:53:01 AM                Humidity:62.1 %
                                                                                                                                Limit1:      —
          so                                                                                                                    Limit2:       =

                                           1                        j                           TL         C
          70

          so
                                           [                        1                           LK         O
          50

          40
                                                  1                                                            2
                 W\mm
          30

          20

          10

          0
          10.0
             1000.000 1100.00    1200.00      1300.00       1400.00        1500.00      1600.00      1700.00        1800.00               2000.00   MHz
    Site :          Chamber
    Condition :            FCC 15.231(433MHz) 1000—2000(PK)                                       Polarization:               Vertical
    EUT :         WeR21805—18133                                                                  Power:            120 ¥ae.
    MAN:                                                                                          Distance: 9m
    Test Mode : TX 433.92MHz
    Note :


    ny.        Frequency     Reading   Detector       Cor. factor         Result         Limit  Ant.Ros |Tab.Pos Margin                   Comment
          f      (MHz)        (dBuy)                    (dB/im)         (dBu¥/im)      (dBu¥/m)   (em)   (deg.)   (d8)
     *           1301.400|    42.80        peak         —9.00            33.80          74.00        150           280    |—40.20
                 1735.200|    41.63     peak            —7.09            34.54          80.80        150           60     |46.26


      _eMc._,
 §              %fi(}\
sWye$. Worldwide Testing Services(Taiwan) Co., Ltd.
liu                     i                      *                     e                       ®                 *



 t    $                                                                  ==
  Cuwom®




                                                        Radiated Emission Measurement                                Operator:        Leon
           File :3                                    Data :#2                            Date: 6/3/2018            Temperature:26.8 °C
           90.0    dBu¥/m                                                                 Time: 6:5§:21 AM          Humidity:62.1 %
                                                                                                                                Limit1:      —
           an                                                                                                                   Limit2       ——
                                L__LIL T1                    L____|                                    J 1
           70


                                L 1                          TS                                        J 1               L
           60


           50

           40               1

           30

           20

           10

           o
           10.0
              2000000 2200.00        2400.00       2600.00      2800.00         3000.00      3200.00     3400.00    3600.00               4000.00 MHz
      Site :            Chamber
      Condition :           FCC15.231(433MHz)} 200041000(PK)                                            Polarization:         Horizontal
      EUT :         WeR21805—18133                                                                      Power:      122 ¥ae.
      MAN:                                                                                              Distance: 9m
      Test Mode : TX 433.92MHz
      Note :


                Frequency        Reading   Detector     Cor. factor             Result        Limit   Ant.Pos |Tab.Pos Margin             Comm ent
      Mk.         (MHz)           (dBuy)                  (dB/im)             (dBu¥/m)      (dBu¥/im)   (em)   (deg.)   (dB)
                2169.000|        41.96         peak          £.13              36.83         80.80       150       270    |43.97
       *        2602.900|        42.72         peak          —3.30             39.42         80.80       150       89     41.38


     _eMc._,
 &          %fi(}\
sWye$. Worldwide Testing Services(Taiwan) Co., Ltd.
&,                   i                        e                     e                       e                 e



*    &                                                                  uy
 Cugom®



                                                       Radiated Emission Measurement                                Operator:        Leon
           File :3                                   Data :#5                            Date: 6/3/2018            Temperature:26.8 °C
           90.0    dBu¥/m                                                                Time: 6:57:18 AM          Humidity:62.1 %
                                                                                                                               Limitt:      ——
           a                                                                                                                   Limit2       Fnmp
                                _A 1                        _                                         I I
           zo

           60

                                L 1                         3                                         J 1               _
           50

           40               1                                                                                 W


           30

           20

           10

           o
           10.0
              2000.000 2200.00      2400.00       2600.00      2800.00         3000.00      3200.00     3400.00    3600.00               4000.00 MHz
     Site :         Chamber
     Condition :            FCC15.231(433MHz)} 200041000(PK)                                           Polarization:         Vertical
     EUT :        WeR21805—18133                                                                       Power:      120 ¥a¢.
     MAN:                                                                                              Distance: 9m
     Test Mode : TX 433.92MHz
     Note :


                Frequency       Reading   Detector     Cor. factor             Result        Limit   Ant.Ros |Tab.Ros Margin              Comment
     MK           (nH2)          (dBuy)                  (4B/im)             (dBu¥/im)     (dBuv/im)   (em)   (deg.)   (d8)
                2169.000|       41.73         peak          £.13              36.60         80.80       150       35     44.20
       *        2602.900|       41.82         peak          —3.30             38.52         80.80       150       214    42.28


  a
    _eMc._,
      sC
A
&
<
&WSE;; Worldwide Testing Services(Taiwan) Co., Ltd.
 +     &
  S wart




                                                Radiated Emission Measurement                         Operator:       Leon
       File :3                                 Data :#3                      Date: 6/3/2018          Temperature:26.8 °C
       90.0      dBu¥/m                                                      Time: 7:01:25 AM         Humidity:62.1 %
                                                                                                                 Limit1:


       " C——TEH——<—~I+9° H
       70



       "50 E—TT—<G— H
              MWWWM
       40

       30

       20

       10

       0
       10.0
          4000.000 4400.00     4800.00   §200.00      5600.00      6000.00      6400.00    6800.00   7200.00               2000.00   MHz
    Site :       Chamber
    Condition :         FCC15.231(433MH2z)} 4000—8000(PK)                                 Polarization:        Horizontal
    EUT :     WeR21805—18133                                                              Power:     120 ¥a«.
    MAN:                                                                                  Distance: 9m
    Test Mode : TX 433.92MHz
    Note :


            Frequency     Reading   Detector    Cor. factor       Result         Limit  Ant.Ros |Tab.Pos Margin            Comment
    Mk.       (MHz)        (dBuy)                 (dB/im)       (dBu¥/im)      (dBu¥/m)   (em)   (deg.)   (d8)


 Registration number: W6R21805-18133-C-1
 FCC ID: GX9FPHUB1




Note   1. Correction Factor = Antenna factor + Cable loss - Preamplifier
       2. The formula of measured value as: Test Result = Reading + Correction Factor
       3. Detector function in the form : PK = Peak, QP = Quasi Peak, AV = Average
       4. All not in the table noted test results are more than 20 dB below the relevant limits.
       5. Measurement uncertainty for 3m measurement: 30-1000 MHz = ± 3.57 dB, 1-18 GHz = ± 2.60
          dB, 18-40 GHz= ± 2.58 dB ; Reported uncertainties represent expanded uncertainties expressed
          at approximately the 95% confidence level using a coverage factor of k = 2.
       6. Up Line: PK Limit Line, Down Line: Ave Limit Line.

All other not noted test plots do not contain significant test results in relation to the limits

Test results: The unit meet the FCC requirements.

Test equipment used: ETSTW-RE 004, ETSTW-RE 030, ETSTW-RE 062, ETSTW-RE 142, ETSTW-
RE 147



Worldwide Testing Services(Taiwan) Co., Ltd.                                                       Page 25 of 31


 Registration number: W6R21805-18133-C-1
 FCC ID: GX9FPHUB1
3.6    Channel Bandwidth
Measurement of Necessary Bandwidth (BN)

        Used frequency                          Bandwidth                    Limit
       433.811523 MHz                          54.1082 kHz                1.0845 MHz




Limits:
The bandwidth of the emission shall be no wider than 0.25% of the center frequency for devices
operating above 70 MHz and below 900 MHz. For devices operating above 900 MHz, the emission
shall be no wider than 0.5% of the center frequency. Bandwidth is determined at the points 20 dB down
from the modulated carrier.

Test equipment used: ETSTW-RE 004




Worldwide Testing Services(Taiwan) Co., Ltd.                                           Page 26 of 31


 Registration number: W6R21805-18133-C-1
 FCC ID: GX9FPHUB1
3.7    Antenna requirement
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
responsible party shall be used with the device. The use of a permanently attached antenna or of an
antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply
with the provisions of this Section. The manufacturer may design the unit so that a broken antenna can
be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited. This
requirement does not apply to carrier current devices or to devices operated under the provisions of
Sections 15.211, 15.213, 15.217, 15.219, or 15.221. Further, this requirement does not apply to
intentional radiators that must be professionally installed, such as perimeter protection systems and
some field disturbance sensors, or to other intentional radiators which, in accordance with Section
15.31(d), must be measured at the installation site. However, the installer shall be responsible for
ensuring that the proper antenna is employed so that the limits in this Part are not exceeded.




Explanation: This Monopole antenna is integral antenna which passes antenna requirement.




                          The equipment meets the               yes           no
                                requirements                                 




Worldwide Testing Services(Taiwan) Co., Ltd.                                                Page 27 of 31


 Registration number: W6R21805-18133-C-1
 FCC ID: GX9FPHUB1
3.8    Duty Cycle


The correction factor, based on the channel dwell time in a 100ms period, may be mathematically
applied to a measurement made with an average detector, to further reduce the measured value.

Average Reading = Peak Reading (dBuV/m) + Duty Cycle Correction

Duty Cycle Correction = 20 log (Cycle)
In order to determine the Duty Cycle, the EUT is measured as:

   Testing Mode        T period                T on             Duty Cycle   Duty Cycle Correction
                         (ms)                  (ms)                           20*log(Duty Cycle)
Transmitting mode        100                   96.13             0.9613              -0.34




Test equipment used: ETSTW-RE 055, ETSTW-RE 004




Worldwide Testing Services(Taiwan) Co., Ltd.                                         Page 28 of 31


 Registration number: W6R21805-18133-C-1
 FCC ID: GX9FPHUB1
3.9    Conducted Measurement at (AC) Power Line
For an intentional radiator which is designed to be connected to the public utility (AC) power line, the
radio frequency voltage that is conducted back onto the AC line on any frequency or frequencies within
the band 150 kHz to 30 MHz shall not exceed the limits in the table bellows with this provision shall be
based on the measurement of the radio frequency voltage between each power line and ground at the
power terminals.

This measurement was transact first with instrumentation using an average and peak detector and a 10
kHz bandwidth. If the peak detector achieves a calculated level, the measurement is repeated by an
instrumentation using a quasi-peak detector.




Worldwide Testing Services(Taiwan) Co., Ltd.                                             Page 29 of 31


 Registration number: W6R21805-18133-C-1
 FCC ID: GX9FPHUB1




Note
       1. The formula of measured value as: Test Result = Reading + Correction Factor
       2. The Correction Factor = Cable Loss + LISN Insertion Loss + Pulse Limit Loss
       3. Detector function in the form : PK = Peak, QP = Quasi Peak, AV = Average
       4. All not in the table noted test results are more than 20 dB below the relevant limits.
       5. Measurement uncertainty = ±1.54 dB; Reported uncertainties represent expanded uncertainties
          expressed at approximately the 95% confidence level using a coverage factor of k = 2.
       6. Up Line: QP Limit Line, Down Line: Ave Limit Line.




Worldwide Testing Services(Taiwan) Co., Ltd.                                             Page 30 of 31


 Registration number: W6R21805-18133-C-1
 FCC ID: GX9FPHUB1


Limits:
           Frequency of Emission (MHz)                  Conducted Limit (dBuV)
                                                   Quasi Peak              Average
                      0.15-0.5                      66 to 56               56 to 46
                       0.5-5                           56                     46
                        5-30                           60                     50


Test equipment used: ETSTW-CE 016, ETSTW-CE 028.




Worldwide Testing Services(Taiwan) Co., Ltd.                                   Page 31 of 31



Document Created: 2018-06-15 15:40:09
Document Modified: 2018-06-15 15:40:09

© 2024 FCC.report