Test Report

FCC ID: GX9BXZW

Test Report

Download: PDF
FCCID_3217412

       FCC PART 15 SUBPART C TEST REPORT
                                  for
                     Wireless Outdoor Bell Box
Model No.: BXx-xxxxx Series (x=0~9, A~Z or blank)
                       FCC ID: GX9BXZW


                                   of
        Applicant:CLIMAX TECHNOLOGY CO., LTD.
       Address: No. 258, Sinhu 2nd Rd., Neihu District 114
                    Taipei City Taiwan (R.O.C.)


                          Tested and Prepared
                                   by

        Worldwide Testing Services (Taiwan) Co., Ltd.
                       FCC Registration No.: 930600

Industry Canada filed test laboratory Reg. No. IC 5679A-1, IC 5107A-1

                      A2LA Accredited No.: 2732.01




                     Report No.: W6M21609-16196-C-1

 6F, NO. 58, LANE 188, RUEY-KUANG RD., NEIHU TAIPEI 114, TAIWAN, R.O.C.
 TEL: 886-2-66068877      FAX: 886-2-66068879   E-mail: wts@wts-lab.com


Registration number: W6M21609-16196-C-1
FCC ID: GX9BXZW


TABLE OF CONTENTS

1     GENERAL INFORMATION ..........................................................................................................2

    1.1     NOTES ..........................................................................................................................................2
    1.2     TESTING LABORATORY ................................................................................................................3
      1.2.1          Location ..............................................................................................................................3
      1.2.2          Details of accreditation status ............................................................................................3
    1.3       DETAILS OF APPROVAL HOLDER ...................................................................................................3
    1.4       APPLICATION DETAILS .................................................................................................................4
    1.5     GENERAL INFORMATION OF TEST ITEM ........................................................................................4
    1.6       TEST STANDARDS .........................................................................................................................4

2     TECHNICAL TEST .........................................................................................................................5

    2.1     SUMMARY OF TEST RESULTS ........................................................................................................5
    2.2     TEST ENVIRONMENT ....................................................................................................................5
    2.3     TEST EQUIPMENT LIST .................................................................................................................6
    2.4     GENERAL TEST PROCEDURE ........................................................................................................8

3     TEST RESULTS (ENCLOSURE) ..................................................................................................9

    3.1       PEAK OUTPUT POWER (TRANSMITTER) ......................................................................................10
    3.2     EQUIVALENT ISOTROPIC RADIATED POWER ................................................................................12
    3.3     RF EXPOSURE COMPLIANCE REQUIREMENTS ............................................................................12
    3.4       OUT OF BAND RADIATED EMISSIONS .........................................................................................12
    3.5       SPURIOUS EMISSION (TX) ...........................................................................................................13
    3.6     RADIATED EMISSIONS FROM DIGITAL PART ..............................................................................14
    3.7       RADIATED EMISSION ON THE BAND EDGE ..................................................................................15
    3.8       POWER LINE CONDUCTED EMISSION .........................................................................................17
    APPENDIX




Worldwide Testing Services(Taiwan) Co., Ltd.                                                                                            Page 1 of 17


Registration number: W6M21609-16196-C-1
FCC ID: GX9BXZW


1      General Information
1.1    Notes

The purpose of conformity testing is to increase the probability of adherence to the essential
requirements or conformity specifications, as appropriate.


The complexity of the technical specifications, however, means that full and thorough testing is
impractical for both technical and economic reasons.


Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to
a specification.


Neither is there any guarantee that such a test sample will interwork with other genuinely open systems.
The existence of the tests nevertheless provides the confidence that the test sample possesses the
qualities as maintained and that is performance generally conforms to representative cases of
communications equipment.


The test results of this test report relate exclusively to the item tested as specified in 1.5.
The test report may only be reproduced or published in full.
Reproduction or publication of extracts from the report requires the prior written approval of the
Worldwide Testing Services(Taiwan) Co., Ltd.


Tester:


September 30, 2016                 Leon Chueh

Date                  WTS-Lab.        Name                            Signature


Technical responsibility for area of testing:


September 30, 2016                  Kevin Wang

Date                  WTS             Name                            Signature



Worldwide Testing Services(Taiwan) Co., Ltd.                                                      Page 2 of 17


Registration number: W6M21609-16196-C-1
FCC ID: GX9BXZW
1.2      Testing laboratory

      1.2.1    Location

OATS
No.5-1, Lishui, Shuang Sing Village,
Wanli Dist., New Taipei City 207,
Taiwan (R.O.C.)
3 meter semi-anechoic chamber
No.35, Aly. 21, Ln. 228, Ankang Rd., Neihu Dist., Taipei City 114, Taiwan (R.O.C.)
TEL:886-2-6613-0228
FAX:886-2-2791-5046

Company
Worldwide Testing Services(Taiwan) Co., Ltd.
6F, NO. 58, LANE 188, RUEY-KUANG RD.
NEIHU, TAIPEI 114, TAIWAN R.O.C.
Tel     : 886-2-66068877
Fax     : 886-2-66068879

      1.2.2    Details of accreditation status

Accredited testing laboratory

A2LA accredited number: 2730.01

FCC filed test laboratory Reg. No. 930600

Industry Canada filed test laboratory Reg. No. IC 5679A-1, IC 5107A-1




Test location, where different from Worldwide Testing Services (Taiwan) Co., Ltd. :
Name:                                    ./.
Accredited number:                       ./.
Street:                                  ./.
Town:                                    ./.
Country:                                 ./.
Telephone:                               ./.
Fax:                                     ./.




Worldwide Testing Services(Taiwan) Co., Ltd.                                          Page 3 of 17


Registration number: W6M21609-16196-C-1
FCC ID: GX9BXZW
1.3    Details of approval holder

Name:                                          CLIMAX TECHNOLOGY CO., LTD.
Street:                                        No. 258, Sinhu 2nd Rd., Neihu District
City:                                          114 Taipei City
Country:                                       Taiwan (R.O.C.)
Telephone:                                     +886-2-2794-0001
Fax:                                           +886-2-2792-6618
1.4    Application details

Date of receipt of test item:                  September 23, 2016
Date of test:                                  from September 26, 2016 to September 30, 2016


1.5    General information of Test item

Type of test item:                      Wireless Outdoor Bell Box
Model Number:                           BXx-xxxxx Series (x=0~9, A~Z or blank)
Multi-listing model number:             ./.
Photos:                                 see Annex

Technical data
Operation Frequency:                    916 MHz
Operation modes:                        duplex
Modulation Type:                        GFSK
Antenna type:                           PCB antenna / 1.56 dBi
Power supply:                           Battery 1.5 Vd.c.*2

Manufacturer: (if different from applicant)
Name:                               ./.
Street:                              ./.
Town:                                ./.
Country:                             ./.
Additional information:              ./.

1.6    Test standards

Technical standard : FCC RULES PART 15 SUBPART C § 15.249 (2015-10)




Worldwide Testing Services(Taiwan) Co., Ltd.                                             Page 4 of 17


Registration number: W6M21609-16196-C-1
FCC ID: GX9BXZW


2      Technical test
2.1    Summary of test results


No deviations from the technical specification(s) were ascertained in the course         :
of the tests performed.

or

The deviations as specified in 2.5 were ascertained in the course of the tests
performed.


2.2    Test environment


Temperature:                             23 oC

Relative humidity content:               20 ... 75 %

Air pressure:                            86 ... 103 kPa

Details Power supply:                    Battery 1.5 Vd.c.*2

Extreme conditions parameters:           Not required


Note:
1. This test report is valid in connection to the model has been tested, any modification to
   the product which is different from the test model will avoid the certification of the test report.
2. This test report shall always be duplicated in full pages unless the written approval of
   the testing laboratory is obtained.
3. The x in model number is representing different case shape, case colors, led mask and customer’s
   number.
4. The model number of EUT is BX-32ZW.




Worldwide Testing Services(Taiwan) Co., Ltd.                                            Page 5 of 17


Registration number: W6M21609-16196-C-1
FCC ID: GX9BXZW
2.3     Test Equipment List
      No.         Test equipment               Type          Serial No.      Manufacturer         Cal. Date        Next Cal.
                                                                                                                     Date
 ETSTW-CE 001    EMI TEST RECEIVER             ESHS10         842121/013           R&S             2016/5/20         2017/5/19

 ETSTW-CE 003    AC POWER SOURCE              APS-9102         D161137              GW                    Function Test
                 HF-EICHLEITUNG RF
 ETSTW-CE 008    STEP ATTENUATOR             334.6010.02      844581/024           R&S                    Function Test
                     139dB DPSP
                  TEMP.&HUMIDITY
 ETSTW-CE 009                              GTH-225-40-1P-U   MAA0305-009      GIANT FORCE          2016/7/15         2017/7/14
                      CHAMBER
 ETSTW-CE 016   TWO-LINE V-NETWORK             ENV216           100050             R&S             2016/9/2          2017/9/1

 ETSTW-RE 003    EMI TEST RECEIVER             ESI 26         831438/001           R&S             2016/5/20         2017/5/19

 ETSTW-RE 004    EMI TEST RECEIVER             ESI 40         832427/004           R&S             2016/5/25         2017/5/24

 ETSTW-RE 005    EMI TEST RECEIVER             ESVS10         843207/020           R&S             2016/7/4          2017/7/3
                TUNABLE BANDREJECT
 ETSTW-RE 012                                 D.C 0309            146              K&L                    Function Test
                       FILTER
                TUNABLE BANDREJECT
 ETSTW-RE 013                                 D.C 0336            397              K&L                    Function Test
                       FILTER
                  MICROWAVE HORN
 ETSTW-RE 018         ANTENNA                  AT4560            27212              AR             2016/6/24         2017/6/23

 ETSTW-RE 027     Passive Loop Antenna          6512           00034563        ETS-Lindgren        2016/6/29         2017/6/28
                Double-Ridged Guide Horn
 ETSTW-RE 030           Antenna                 3117           00035224        ETS-Lindgren        2016/3/23         2017/3/22

 ETSTW-RE 042      Biconical Antenna           HK116            100172             R&S             2016/1/25         2017/1/24
                   Log-Periodic Dipole
 ETSTW-RE 043                                  HL223            100166             R&S             2016/3/28         2017/3/27
                        Antenna
 ETSTW-RE 044     Log-Periodic Antenna         HL050            100094             R&S             2016/4/14         2017/4/13
                    ESA-E SERIES
 ETSTW-RE 045   SPECTRUM ANALYZER              E4404B         MY45111242          Agilent                 Pre-test Use

 ETSTW-RE 050       Attenuator 10dB          50HF-010-1          None              JFW             2016/2/25         2017/2/24

 ETSTW-RE 051        Attenuator 6dB          50HF-006-1          None              JFW             2016/2/25         2017/2/24

 ETSTW-RE 053        Attenuator 3dB          50HF-003-1          None              JFW             2016/2/25         2017/2/24

 ETSTW-RE 055   SPECTRUM ANALYZER              FSU 26           200074             R&S             2016/2/27         2017/2/26

 ETSTW-RE 060       Attenuator 30dB            5015-30        F651012z-01          ATM             2016/2/25         2017/2/24

 ETSTW-RE 062       Amplifier Module           CHC 2             None              KMIC            2016/4/13         2017/4/12

 ETSTW-RE 064      Bluetooth Test Set       MT8852B-042       6K00005709          Anritsu                 Function Test
                Double-Ridged Guide Horn
 ETSTW-RE 069           Antenna                 3117           00069377        ETS-Lindgren               Function Test

 ETSTW-RE 072    CELL SITE TEST SET            8921A          3339A00375            HP             2016/9/2          2017/9/1
                     SOLID STATE
 ETSTW-RE 088                              KMA180265A01          99057             KMIC            2016/9/14         2017/9/13
                      AMPLIFIER
 ETSTW-RE 099          DC Block              50DB-007-1          None              JFW             2016/2/25         2017/2/24

 ETSTW-RE 112    AC POWER SOURCE              TFC-1005        T-0A023536          T-Power                 Function test
                                                                              MICROWAVE
 ETSTW-RE 115      2.4GHz Notch Filter        N0124411          473874         CIRCUITS            2016/1/13         2017/1/12

 ETSTW-RE 120          RF Player               MP9200        MP9210-111022        ADIVIC                  Function test

 ETSTW-RE 122    SIGNAL GENERATOR             SMF100A           102149             R&S             2016/5/23         2017/5/22
                                              5NSL11-
 ETSTW-RE 125       5GHz Notch filter                              1          K&L Microwave        2016/8/10         2017/8/9
                                           5200/E221.3-O/O
                                              5NSL12-
 ETSTW-RE 126       5GHz Notch filter                              1          K&L Microwave        2016/8/10         2017/8/9
                                           5800/E221.3-O/O
 ETSTW-RE 127        RF Switch Box             RFS-01            None              WTS             2016/2/25         2017/2/24

 ETSTW-RE 128      5.3GHz Notch filter        N0153001         SN487233      Microwave Circuits    2016/8/10         2017/8/9



Worldwide Testing Services(Taiwan) Co., Ltd.                                                                   Page 6 of 17


Registration number: W6M21609-16196-C-1
FCC ID: GX9BXZW
 ETSTW-RE 129       5.5GHz Notch filter        N0555984           SN487234        Microwave Circuits   2016/8/10         2017/8/9
                  Handheld RF Spectrum
 ETSTW-RE 130          Analyzer                 N9340A          CN0147000204           Agilent                Pre-test Use

 ETSTW-RE 142            Amplifier               8447D           2805A03378            Agilent         2016/4/13        2017/4/12
                   Humidity Temperature
 ETSTW-RE 143             Meter                TES-1260           110104623             TES            2016/8/19        2017/8/18

 ETSTW-RE 147      Bi-log Hybrid Antenna      MCTD 2786B        BLB16M04005             ETC            2016/3/31        2017/3/30

ETSTW-EMI 011     USB Compact Modulator          SFC-U              101689              R&S            2016/5/4          2017/5/3
                     Universal Radio
ETSTW-GSM 002      Communication Tester        CMU 200              109439              R&S            2016/3/4          2017/3/3
                   Radio Communication
ETSTW-GSM 003            Analyzer              MT8820C            6201342073           Anritsu         2016/2/3          2017/2/2
                                            WRCTF824/849-
ETSTW-GSM 019        Band Reject Filter    822/851-40 /12+9SS         3                  WI            2016/1/13        2017/1/12
                                            WRCD1747/1748-
ETSTW-GSM 020        Band Reject Filter     1743/1752-32/5SS          1                  WI            2016/1/13        2017/1/12
                                           WRCD1879.5/1880.5
ETSTW-GSM 021        Band Reject Filter      -1875.5/1884.5-          3                  WI            2016/1/13        2017/1/12
                                                 32/5SS
                                           WRCT901.9/903.1-
ETSTW-GSM 022        Band Reject Filter       904.25-50/8SS           1                  WI            2016/1/13        2017/1/12

ETSTW-GSM 023         Power Divider            4901.19.A             None             SUHNER           2016/9/14        2017/9/13

ETSTW-Cable 010         BNC Cable            5 M BNC Cable           None         JYE BAO CO.,LTD.     2016/9/2          2017/9/1

ETSTW-Cable 011         BNC Cable             BNC Cable 1            None         JYE BAO CO.,LTD.          Pre-test Use NCR

ETSTW-Cable 012   N TYPE To SMA Cable          Cable 012             None         JYE BAO CO.,LTD.     2016/9/2          2017/9/1

ETSTW-Cable 016         BNC Cable              Switch Box          B Cable 1        Schwarz beck       2016/2/24        2017/2/23

ETSTW-Cable 017         BNC Cable               X Cable            B Cable 2        Schwarz beck       2016/2/24        2017/2/23

ETSTW-Cable 018         BNC Cable               Y Cable            B Cable 3        Schwarz beck       2016/2/24        2017/2/23

ETSTW-Cable 019         BNC Cable               Z Cable            B Cable 4        Schwarz beck       2016/2/24        2017/2/23

ETSTW-Cable 020       N TYPE Cable           OATS Cable 1       N30N30-L335-15M   JYE BAO CO.,LTD.     2016/4/22        2017/4/21

ETSTW-Cable 022       N TYPE Cable               5006                0002         JYE BAO CO.,LTD.     2016/4/7          2017/4/6

ETSTW-Cable 026      Microwave Cable         SUCOFLEX 104           279075        HUBER+SUHNER         2016/2/25        2017/2/24

ETSTW-Cable 027      Microwave Cable         SUCOFLEX 104           279083        HUBER+SUHNER         2016/5/13        2017/5/12

ETSTW-Cable 028      Microwave Cable        FA147A0015M2020        30064-2            UTIFLEX          2016/9/14        2017/9/13

ETSTW-Cable 029      Microwave Cable        FA147A0015M2020        30064-3            UTIFLEX          2016/9/14        2017/9/13
                                            SUCOFLEX 104
ETSTW-Cable 030      Microwave Cable                                279067        HUBER+SUHNER         2016/2/25        2017/2/24
                                             (S_Cable 9)
                                            SUCOFLEX 104
ETSTW-Cable 031      Microwave Cable        (S_Cable 10)            238092        HUBER+SUHNER         2016/4/13        2017/4/12

ETSTW-Cable 043      Microwave Cable        SUCOFLEX 104            317576        HUBER+SUHNER         2016/4/13        2017/4/12

ETSTW-Cable 048      Microwave Cable        SUCOFLEX 104            325518        HUBER+SUHNER         2016/4/13        2017/4/12

ETSTW-Cable 058      Microwave Cable        SUCOFLEX 104             none         HUBER+SUHNER         2016/4/7          2017/4/6

ETSTW-Cable 064      Microwave Cable        SUCOFLEX 104           MY28891        HUBER+SUHNER         2016/4/13        2017/4/12

WTSTW-SW 002      EMI TEST SOFTWARE             EZ_EMC               None               Farad              Version ETS-03A1




Worldwide Testing Services(Taiwan) Co., Ltd.                                                                       Page 7 of 17


Registration number: W6M21609-16196-C-1
FCC ID: GX9BXZW


2.4    General Test Procedure

POWER LINE CONDUCTED INTERFERENCE: The procedure used was ANSI STANDARD
C63.10-2013 6.2 using a LISN (if necessary). Both lines were observed. The bandwidth of the spectrum
analyzer was 10 kHz with an appropriate sweep speed.

RADIATION INTERFERENCE: The test procedure used was according to ANSI STANDARD
C63.10-2013 6.3 employing a spectrum analyzer. For investigated frequency is equal to or below 1GHz,
the RBW and VBW of the spectrum analyzer was 100 kHz and 100kHz respectively with an
appropriate sweep speed. For investigated frequency is above 1GHz, both of RBW and VBW of the
spectrum analyzer were 1 MHz with an appropriate sweep speed. The analyzer was calibrated in dB
above a microvolt at the output of the antenna.

FORMULA OF CONVERSION FACTORS: The Field Strength at 3m was established by adding the
meter reading of the spectrum analyzer (which is set to read in units of dBµV) to the antenna correction
factor supplied by the antenna manufacturer. The antenna correction factors are stated in terms of dB.
Example:
Freq (MHz)       METER READING + ACF + CABLE LOSS (to the receiver) = FS
33               20 dBµV + 10.36 dB + 6 dB = 36.36 dBµV/m @3m

ANSI STANDARD C63.10-2013 6.2.2 MEASUREMENT PROCEDURES: The EUT was placed on a
table 80 cm height and with dimensions of 1m by 1.5m (non metallic table). The EUT was placed in the
centre of the table. The table used for radiated measurements is capable of continuous rotation. The
spectrum was scanned from 30 MHz to 10th harmonic of the fundamental.


Peak readings were taken in three (3) orthogonal planes and the highest readings.
Measurements were made by Worldwide Testing Services(Taiwan) Co., Ltd. at the registered open field
test site located at No.5-1, Lishui, Shuang Sing Village, Wanli Dist., New Taipei City 207, Taiwan
(R.O.C.). The Registration Number: 930600.

When an emission was found, the table was rotated to produce the maximum signal strength. At this
point, the antenna was raised and lowered from 1m to 4m. The antenna was placed in both the
horizontal and vertical planes.

ANSI STANDARD C63.10-2013 B.2.7: Any measurements that utilize special test software shall be
indicated and referenced in the test report. During testing, test software ’EZ EMC’ was used for setting
up different operation modes.




Worldwide Testing Services(Taiwan) Co., Ltd.                                              Page 8 of 17


Registration number: W6M21609-16196-C-1
FCC ID: GX9BXZW


3        Test results (enclosure)


                                                                        Para.   Required Test      Test
                               Test case
                                                                      Number             passed   failed
    Peak Output Power                                                15.249 (a)    :       :
    Spurious Emissions radiated – Transmitter operating              15.249 (e)   :        :
    Spurious Emissions conducted – Transmitter operating             15.249 (e)
    Radiated Emission from Digital Part                               15.109
    Out of Band Spurious Emission, Band edge-Transmitter operating   15.249 (e)   :        :
    Power Line Conducted Emission                                     15.207


The following is intentionally left blank.




Worldwide Testing Services(Taiwan) Co., Ltd.                                               Page 9 of 17


Registration number: W6M21609-16196-C-1
FCC ID: GX9BXZW
3.1    Peak Output Power (transmitter)
FCC Rule: 15.249 (b)

This measurement applies to equipment with an integral antenna and to equipment with an antenna
connector and equipped with an antenna as declared by the applicant.

The power was measured with modulation (declared by the applicant).




Worldwide Testing Services(Taiwan) Co., Ltd.                                      Page 10 of 17


Registration number: W6M21609-16196-C-1
FCC ID: GX9BXZW




Test equipment used: ETSTW-RE 004, ETSTW-RE 030, ETSTW-RE 062, ETSTW-RE 142,
                    ETSTW-RE 147




Worldwide Testing Services(Taiwan) Co., Ltd.                                   Page 11 of 17


Registration number: W6M21609-16196-C-1
FCC ID: GX9BXZW
3.2    Equivalent isotropic radiated power

Because using an permanent antenna there are no deviations from the radiated test results according 3.1.

3.3    RF Exposure Compliance Requirements

Not applicable for this EUT for the low power level.


3.4    Out of Band Radiated Emissions
FCC Rule: 15.249 (d)(e), 15.35(b)

Emissions radiated outside of the specified frequency bands, except for harmonics, shall be attenuated
by at least 50 dB below the level of the fundamental or to the general radiated emission limits in Section
15.209, whichever is the lesser attenuation.

For frequency above 1000 MHz, the field strength limits are based on average limits. However, the peak
field strength of any emission shall not exceed the maximum permitted average limits specified above
by more than 20 dB under any condition of modulation. For point-to-point operation, the peak field
strength shall not exceed 2500 millivolts/meter at 3 meters along the antenna azimuth.

Limits:
   Frequency of Emission                   Field strength                    Field Strength
           (MHz)                         (microvolts/meter)               (dB microvolts/meter)
           30 - 88                              100                               40.0
          88 – 216                              150                               43.5
         216 – 960                              200                               46.5
        Above 960                               500                               54.0

For frequencies above 1 GHz (Peak measurements).

Limit + 20 dB     54.0 dBµV/m + 20 dB= 74dBµV/m
Or
Must be attenuated at least 50dB below the level of fundament


Test equipment used: ETSTW-RE 004, ETSTW-RE 062, ETSTW-RE 142, ETSTW-RE 147, ETSTW-RE
030


Explanation: Please see attached diagram as appendix.




Worldwide Testing Services(Taiwan) Co., Ltd.                                                Page 12 of 17


Registration number: W6M21609-16196-C-1
FCC ID: GX9BXZW
3.5    Spurious emission (tx)
Spurious emission was measured with modulation (declared by manufacturer).

Emissions radiated outside of the specified frequency bands, except for harmonics, shall be attenuated
by at least 50 dB below the level of the fundamental or to the general radiated emission limits in Section
15.209, whichever is the lesser attenuation.

For frequencies above 1000 MHz, the field strength limits are based on average limits. However, the
peak field strength of any emission shall not exceed the maximum permitted average limits specified
above by more than 20 dB under any condition of modulation. For point-to-point operation, the peak
field strength shall not exceed 2500 millivolts/meter at 3 meters along the antenna azimuth.

SAMPLE CALCULATION OF LIMIT. ALL results will be updated by an automatic measuring system
in accordance with point 2.3.

The peak and average spurious emission plots was measured with the average limits.
The critical peak value listed in the table agree with the above calculated limits.
Summary table with radiated data of the test plots
                         BXx-xxxxx Series
     Model:           (x=0~9, A~Z or blank) Date:                        --
     Mode:                         --             Temperature:           -- °C      Engineer: --
     Polarization: Horizontal                      Humidity:             -- %
                                                                                      Table   Ant.
       Frequency Reading                   Factor     Result       Limit Margin
                                Detector                                             Degree High
         (MHz)       (dBuV)                 (dB)    (dBuV/m) (dBuV/m) (dB)
                                                                                     (Deg.) (cm)
            --           --          --      --          --          --        --      --      --
            --           --          --      --          --          --        --      --      --

       Frequenc                                                               Margi Table
           y        Reading       Factor       Result @3m     Limit @3m        n Degre Ant.
                    (dBuV)         (dB)         (dBuV/m)      (dBuV/m)                e   High
        (MHz)     Peak Ave.       Corr.        Peak Ave.      Peak Ave.       (dB) (Deg.) (cm)
          --       --     --        --          --     --     --      --       --    --     --
          --       --     --        --          --     --     --      --       --    --     --

Note   1. Correction Factor = Antenna factor + Cable loss - Preamplifier
       2. The formula of measured value as: Test Result = Reading + Correction Factor
       3. Detector function in the form : PK = Peak, QP = Quasi Peak, AV = Average
       4. All not in the table noted test results are more than 20 dB below the relevant limits.
       5. Measurement uncertainty for 3m measurement: 30-1000 MHz = ± 4.69 dB, 1-18 GHz = ± 4.78
          dB, 18-40 GHz= ± 2.44 dB ; Reported uncertainties represent expanded uncertainties expressed
          at approximately the 95% confidence level using a coverage factor of k = 2.
       6. Up Line: PK Limit Line, Down Line: Ave Limit Line.
       7. See attached diagrams in appendix.

TEST RESULT (Transmitter): The unit DOES meet the FCC requirements.

Test equipment used: ETSTW-RE 004, ETSTW-RE 062, ETSTW-RE 142, ETSTW-RE 147,
                     ETSTW-RE 030, ETSTW-RE 088, ETSTW-RE 018

Worldwide Testing Services(Taiwan) Co., Ltd.                                                Page 13 of 17


Registration number: W6M21609-16196-C-1
FCC ID: GX9BXZW


3.6      Radiated Emissions from Digital Part

Summary table with radiated data of the test plots

Except for Class A digital devices, the field strength of radiated emissions from unintentional radiators
at a distance of 3 meters shall not exceed the following values:

       Frequency of Emission                Field Strength                  Field Strength
               (MHz)                      (microvolts/meter)             (dBmicrovolts/meter)
               30 – 88                           100                             40.0
              88 – 216                           150                             43.5
             216 – 960                           200                             46.0
            Above 960                            500                             54.0

Note

1.     Correction Factor = Antenna factor + Cable loss - Preamplifier
2.     The formula of measured value as: Test Result = Reading + Correction Factor
3.     Detector function in the form : PK = Peak, QP = Quasi Peak, AV = Average
4.     All not in the table noted test results are more than 20 dB below the relevant limits.
5.     Measurement uncertainty for 3m measurement : 30-1000 MHz = ± 4.69 dB, 1-18 GHz = ±4.78 dB,
       18-40 GHz= ±2.44 dB ; Reported uncertainties represent expanded uncertainties expressed
       at approximately the 95% confidence level using a coverage factor of k = 2.



Test equipment used: ETSTW-RE 004, ETSTW-RE 062, ETSTW-RE 142, ETSTW-RE 147,
                      ETSTW-RE 030,


Explanation: The test results are listed in the separated test report no.: W6M21609-16196-P-15B.




Worldwide Testing Services(Taiwan) Co., Ltd.                                               Page 14 of 17


Registration number: W6M21609-16196-C-1
FCC ID: GX9BXZW


3.7    Radiated Emission on the band edge

From the following plots, they show that the fundamental emissions are confined in the specified band
and hey at least 50 dB below the carrier level at band edge (2400 and 2483.5 MHz). It meets the
requirement of section 15.249(d).




Worldwide Testing Services(Taiwan) Co., Ltd.                                             Page 15 of 17


Registration number: W6M21609-16196-C-1
FCC ID: GX9BXZW




Limit:

                                                 Limit (dBμV/m)
                       Frequency Range (MHz)
                                               Peak         Average
                              902 – 928        114            94
                            2400 – 2483.5       74            54
                             5725 – 5875        74            54

Test equipment used: ETSTW-RE 004, ETSTW-RE 030, ETSTW-RE 062, ETSTW-RE 142, ETSTW-RE
147




Worldwide Testing Services(Taiwan) Co., Ltd.                              Page 16 of 17


Registration number: W6M21609-16196-C-1
FCC ID: GX9BXZW
3.8    Power Line Conducted Emission

For an intentional radiator which is designed to be connected to the public utility (AC) power line, the
radio frequency voltage that is conducted back onto the AC line on any frequency or frequencies within
the band 150 kHz to 30 MHz shall not exceed the limits in the table bellows with this provision shall be
based on the measurement of the radio frequency voltage between each power line and ground at the
power terminals.
This measurement was transact first with instrumentation using an average and peak detector and a 10
kHz bandwidth. If the peak detector achieves a calculated level, the measurement is repeated by an
instrumentation using a quasi-peak detector.
                                                                   Level (dBµV)
          Frequency
                                             quasi-peak                                  average
           150 kHz                         lower limit line                           Lower limit line

                          BXx-xxxxx Series
            Model:                              Date:              --
                        (x=0~9, A~Z or blank)
             Mode:            --         Temperature:         --     °C            Engineer:       --
          Polarization:   --              Humidity:           --     %
            Frequency          Reading        Factor             Result              Limit       Margin
                                (dBuV)         (dB)             (dBuV)              (dBuV)
              (MHz)          QP Ave.          Corr.           QP Ave.             QP Ave.         (dB)
                 --          --        --        --           --        --        --       --      --
                 --          --        --        --           --        --        --       --      --
                 --          --        --        --           --        --        --       --      --

          Polarization:    --
            Frequency             Reading       Factor           Result              Limit       Margin
                                   (dBuV)        (dB)           (dBuV)              (dBuV)
              (MHz)             QP Ave.         Corr.         QP Ave.             QP Ave.         (dB)
                --              --        --       --         --        --        --       --      --
                --              --        --       --         --        --        --       --      --
                --              --        --       --         --        --        --       --      --
Note:
1. The formula of measured value as: Test Result = Reading + Correction Factor
2. The Correction Factor = Cable Loss + LISN Insertion Loss
3. Detector function in the form : PK = Peak, QP = Qusai Peak, AV = Average
4. All not in the table noted test results are more than 20 dB below the relevant limits.
5. Measurement uncertainty = ±1.14 dB; Reported uncertainties represent expanded uncertainties
   expressed at approximately the 95% confidence level using a coverage factor of k = 2.
6. Up Line: QP Limit Line, Down Line: Ave Limit Line.
7. This test is not required because the EUT is battery-used.

Limits:
             Frequency of Emission (MHz)                                     Conducted Limit (dBuV)
                                                                        Quasi Peak              Average
                          0.15-0.5                                       66 to 56               56 to 46
                           0.5-5                                            56                     46
                            5-30                                            60                     50
Test equipment used: ETSTW-CE 001, ETSTW-CE 016, ETSTW-CE 028

Worldwide Testing Services(Taiwan) Co., Ltd.                                                            Page 17 of 17


Registration number: W6M21609-16196-C-1
FCC ID: GX9BXZW




Appendix
Measurement diagrams

Spurious Emissions radiated




Worldwide Testing Services(Taiwan) Co., Ltd.   Appendix Page


                                                Address:8F,,N0.58,Ln 188,Ruey Kuang Rd.Neihu,Taipei
                                                Tel:+886—2—6606—8877
                                                Fax:+886—2—6606—8875
                                                  Radiated Emission Measurement                   Operator:— Leon
        File :1                                  Data #1             Date: 2016/0/29              Temperature:24 °C
        80.0      dBu¥/m                                                   Time: E4 07:22:00      Humidity:60 %
                                                                                                           Limit:       —
        70
        so
        so
        an |—
        ao
                         1
        2o
        10
        o
     10
     208
        suomo rz7i00  2rao    arilo0   eteon  siso0                           bi2.00__rosno      enon               Touo oo mz
   Site : Chamber
   Condition : FCC_part 15 RE—Class C_80—1000MHz                                       Polarization: Horizontal
   EUT : WeM21608—16196                                                                Power : 3¥4e.
   M/N:                                                                                Distance: 9n
   Test Mode : TX 916MHz
   Note :

             Frequency        Reading   |Deteior Gorr. factor    Result       Timit    AntPos |Tab.Pos Margin       Gomment
   Mol          qing          (dbu)                 (dBm)       (4Bu¥im)    (@Bu¥im)    (om)    tdea    (48)
    *          127.1944)      28.02      posk       —6.19        21.83       43.50      150     230    |—21.87
               224.3888)      31.27      posk       —8.06        22.21       46.00      150     175    |—2379




*@Maximum data               x:Over limit   !:over margin


                                                Address:8F,,N0.58,Ln 188,Ruey Kuang Rd.Neihu,Taipei
                                                Tel:+886—2—6606—8877
                                                Fax:+886—2—6606—8875
                                                  Radiated Emission Measurement                   Operator:— Leon
        File :1                                  Data #2             Date: 2016/0/29              Temperature:24 °C
        80.0      dBu¥/m                                                   Time: E4 07:17:54      Humidity:60 %
                                                                                                           Limit:       —
        70
        so
        so
        an |—
        ao
                         1
        2o
        10
        o
     10
     208
        suumo rz7i00  2rau    ario0    aeon   siso0                           bi2.00__rosno      enon               Touo oo mz
   Site : Chamber
   Condition : FCC_part 15 RE—Class C_80—1000MHz                                       Polarization: Vertical
   EUT : WeM21608—16196                                                                Power : 3¥4e.
   M/N:                                                                                Distance: 9n
   Test Mode : TX 916MHz
   Note :

             Frequency        Reading   |Deteior Gorr. factor    Result       Timit    AntPos |Tab.Pos Margin       Gomment
   Mol          qing          (dbu)                 (dBm)       (4Bu¥im)    (@Bu¥im)    (om)    tdea    (48)
               127.1944)      27.77      posk       —6.19        21.58       43.50      150      85    |—2192
    *          609.27B5)      28.70      posk       —0.87        27.83       46.00      150     160    |—1817




*@Maximum data               x:Over limit   !:over margin


                                     Address:8F,,N0.58,Ln 188,Ruey Kuang Rd.Neihu,Taipei
                                     Tel:+886—2—6606—8877
                                     Fax:+886—2—6606—8875
                                         Radiated Emission Measurement                   Gperator: Leon
     File :3                           Data #1                    Date: 2016/0/29        Temporature:24 °C
     90.0   dBuV/m                                                Time: E4 08:41:56      Humidity:60 %
                                                                                                  Limit:        —
     sn                                                                                           Limite:      —

     70
     so
     so

     ®                              ‘WWMMWWWM
     an
     20
     10
      o
     108
        1000000 1300.00 toon.o0 1900.00 2e00.00__2so0.00             2oon.o0   sro0.00__s«00.00             «000 00 htz
   Site : Chamber
   Condition : FCCpart 15 RE—Class C_Above 1GHz_PK                             Polarization: Horizontal
   EUT : WeM21608—16196                                                        Power : 3¥4e.
   M/N:                                                                        Distance: 9n
   Test Mode : TX 916MHz
   Note :

          Frequency Reading    |Deteior Gorr. factor    Result        Timit  AntPos |Tab.Pos Margin         Gomment
   Mel      qing     (dbuy)                (d®m)       (dBu¥im)     (@Bu¥im) (om)    tdea) (48)
    *|     1832000] 41.39       peak       —6.55        sass         7a0o     is0     iss |—so.17




*@Maximum data       x:Over limit   !:over margin


                                        Address:8F,,N0.58,Ln 188,Ruey Kuang Rd.Neihu,Taipei
                                        Tel:+886—2—6606—8877
                                        Fax:+886—2—6606—8875
                                          Radiated Emission Measurement                  Gperator:     Leon
     File :3                             Data #4                  Date: 2016/0/29        Temporature:24 °C
     90.0   dBuV/m                                                Time: 4 08:48:06       Humidity:60 %
                                                                                                  Limit:        —
     sn                                                                                           Limite:      —

     70
     so
     so
     an                             4
     an
     20
     10
      o
     108
        1000000 1300.00 toon.o0 1900.00 2e00.00__2so0.00             2oon.o0   sro0.00__s«00.00             «000 00 htz
   Site : Chamber
   Condition : FCCpart 15 RE—Class C_Above 1GHz_PK                             Polarization: Vertical
   EUT : WeM21608—16196                                                        Power : 3¥4e.
   M/N:                                                                        Distance: n
   Test Mode : TX 916MHz
   Note :

          Frequency Reading    |Deteior Gorr. factor    Result        Timit  AntPos |Tab.Pos Margin         Gomment
   Mel      qing     (dbuy)                (d®m)       (dBu¥im)     (@Bu¥im) (om)    tdea) (48)
    *|     1832000] 41.59       peak       —6.55        ssos         7a0o     iso     210 |—ss97




*@Maximum data       x:Over limit   !:over margin


                                             Address:8F,,N0.58,Ln 188,Ruey Kuang Rd.Neihu,Taipei
                                             Tel:+886—2—6606—8877
                                             Fax:+886—2—6606—8875
                                                 Radiated Emission Measurement                          Gperator: Leon
        File :3                                 Data #2                     Date: 20180729              Temperature:24 °C
        90.0     dBuV/m                                                     Time: F4 08:44:15           Humidity:60 %
                                                                                                                    Limit      —
        sn                                                                                                          Limit®     —


        70

        so                                                                        1
        50
                                                                                   agenctrnimemi
        41 Aevstarmae
        sn
        20

        10
        0

        4108
             «000000 4400.00   000.00—    5200.00      sean.00     6000.00—    6400.00    ©200.00—     7200.00               800000 MHz

   Site : Chamber
   Condition : FCCpart 15 RE—Class CAbove 1GHz_PK                                        Polarization: Horizontal
   EUT : WeMz1608—10196                                                                  Power : 3¥4s.
   M/N:                                                                                  Distance: n
   Test Mode : TX 916MHz
   Note :

             Frequency     Reading   Detector    Core factor      Result       Limit     AntBos Tab.Pos      Margin          Comment
   Mcl—        qing        (dbuy)                   (dBm)        (dBu¥im)     (dBuvim)    (om)       (deg)       (@B)
               B412828| 5289          posk          .21           sei0        7a00        1so        258 |—17%0
    *          s4izsz| 4ssz           ava           .21           68e         5400        is0        25 717




*@Maximum data            x:Over limit    Lsover margin


                                             Address:8F,,N0.58,Ln 188,Ruey Kuang Rd.Neihu,Taipei
                                             Tel:+886—2—6606—8877
                                             Fax:+886—2—6606—8875
                                                 Radiated Emission Measurement                          Gperator: Leon
        File :3                                 Data #5                     Date: 20180729             Temperature:24 °C
        90.0     dBuV/m                                                     Time: F4 08:45:57           Humidity:60 %
                                                                                                                    Limit      —
        sn                                                                                                          Limit®     —


        70

        so                                                                        1
        50
                                                                                   fls
        41 ttncnstrmaa
        sn
        20

        10
        0

        4108
             «000000 4400.00   000.00—    5200.00      sean.00     6000.00—    6400.00    ©200.00—     7200.00               800000 MHz

   Site : Chamber
   Condition : FCCpart 15 RE—Class CAbove 1GHz_PK                                        Polarization: Vertical
   EUT : WeMz1608—10196                                                                  Power : 3¥4s.
   M/N:                                                                                  Distance: n
   Test Mode : TX 916MHz
   Note :

             Frequency     Reading   Detector    Core factor      Result       Limit     AntBos Tab.Pos      Margin          Comment
   Mcl—        qing        (dbuy)                   (dBm)        (dBu¥im)     (dBuvim)    (om)       (deg)       (@B)
               B412828| 5286          posk          .21           seor        7amo        180        2s |—1795
    *          s4izsz| 4ser           ava           .21           46ss        5400        is0        275 712




*@Maximum data            x:Over limit    Lsover margin


                                             Address:8F,,N0.58,Ln 188,Ruey Kuang Rd.Neihu,Taipei
                                             Tel:+886—2—6606—8877
                                             Fax:+886—2—6606—8875
                                               Radiated Emission Measurement                     Gperator:      Leon
        File :3                               Data #3                   Date: 2016/0/29          Temperature:24 °C
        90.0    dBu¥/m                                                  Time: F4 08:47:18.__Humidity:60 %
                                                                                                          Limit:        —
        so                                                                                                Limite:      —

        70
        so


        i flw
                  1

        an
        an
        20
        10
      o
     108
        sone ooo ma7s oo besn o0 Sazs 00 suo.00 toars 00 Toosn 00 11325.00_t1o00.00       Terso o0z
   Site : Chamber
   Condition : FCCpart 15 RE—Class C_Above 1GHz_PK                Polarization:    Horizontal
   EUT : WeM21608—16196                                           Power : 3¥4e.
   M/N:                                                                              Distance: 9n
   Test Mode : TX 916MHz
   Note :

             Frequency     Reading   |Deteior Gorr. factor    Result       Timit     AntPos |Tab.Pos Margin         Gomment
   Mcl—        qing        (dbuy)                (dBm)       (dBu¥im)     (dBuvim)    (om)    (deg)    (@B)
              8237.970|    48.14      peak        5.42        sese        7a0o        150     i7s     |—2044
              sasr9re|     s95s       aVvG        5.42        aass        sa00        is0     175      902
             10076.034|    49.85      peak        7.99        srea        Tamo        150     180     |—16.16
    *        ioorsasal     sese       ave         799         arss        sa00        is0     180      |—662




*@Maximum data            x:Over limit   !:over margin


                                                Address:8F,,N0.58,Ln 188,Ruey Kuang Rd.Neihu,Taipei
                                                Tel:+886—2—6606—8877
                                                Fax:+886—2—6606—8875
                                                  Radiated Emission Measurement                    Gperator:       Leon
        File :8                                  Data #8                    Date: 2016/0/20        Temperature:24 °C
        90.0     dBu¥/m                                                     Time: 4 08:48:24       Humidity:60 %
                                                                                                              Limit:       —
        so                                                                                                    Limite:     —

        70
        so
        so
        an         ageretreracare—inoti

        an
        20
        10
        o
        108
          sone ooo ma7s oo      besn o0     Sazs.00     suo.00     toars 00 Toosn 00 11325.00_t1o00.00                  Terso o0z
   Site :   Chamber
   Condition : FCC_part 15 RE—Class C_Above 1GHz_PK                                    Polarization:        Vertical
   EUT :        WeM21608—16196                                                         Power :    3¥6e.
   M/N:                                                                                Distance: 9n
   Test Mode : TX 91GMHz
   Note :

             Frequency      Reading   |Deteior Gorr. factor       Result        Timit  AntPos |Tab.Pos Margin           Gomment
   Mel         qing          (dbuy)               (d®m)          (dBu¥im)     (@Bu¥im) (om)    tdea) (48)
               8237.970|    47.36      poak           5.42        52.78       74.00      150     175   |—2122
               8237.970|    37.75         AVG         5.42        48.17        54.00     150     175   |—1083
             10078.150|     48.61      poak           7.99        55.50       74.00      150     230   |—1740
    *        1007s.150]     39.63         AVG         7.99        47.62        54.00     150     230      |—6.38




*@Maximum data             x:Over limit     t:over margin