Test Report

FCC ID: GU6-SDMAN

Test Report

Download: PDF
FCCID_2395788

RF TEST
REPORT

 Report No.: FCC_RF_SL13092401-AVE-031_WLAN Rev1.0
 Supersede Report No.: FCC_RF_SL13092401-AVE-031_WLAN


 Applicant           Avery Dennison
 Product Name        SDIO Wireless Module
 Model No.           SX-SDMAN
                     47CFR15.247, RSS-210 Issue8: 2010
 Test Standard

                     ANCI C63.4:2009
 Test Method
                     47CFR15.247, RSS-210 Issue8: 2010
 FCC ID              GU6-SDMAN
 IC ID               1502A-SDMAN
 Date of test        12/09/2013 - 12/31/2013
 Issue Date          7/18/2014
 Test Resut          Pass                Fail
 Equipment complied with the specification                       [x]
 Equipment did not comply with the specification                 [ ]




                        David Zhang                                                     Nima Molaei
                        Test Engineer                                               Engineer Reviewer
                                     This test report may be reproduced in full only
                     Test result presented in this test report is applicable to the tested sample only

                                                   Issued By:
                                              SIEMIC Laboratories
                                   775 Montague Expressway, Milpitas, 95035 CA




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:


                                                                 Test report No.      FCC_RF_SL13092401-AVE-031_WLAN Rev1.0
                                                                 Page                 2 of 26




                                          Laboratory Introduction
SIEMIC, headquartered in the heart of Silicon Valley, with superior facilities in US and Asia, is one of the leading independent test ing
and certification facilities providing customers with one-stop shop services for Compliance Testing and Global Certifications.




In addition to testing and certification, SIEMIC provides initial design reviews and compliance management throughout a project. Our
extensive experience with China, Asia Pacific, North America, European, and International compliance requirements, assures the
fastest, most cost effective way to attain regulatory compliance for the global markets.

                                   Accreditations for Conformity Assessment
           Country/Region                  Accreditation Body                                      Scope
                USA                             FCC, A2LA                              EMC , RF/Wireless , Telecom
              Canada                         IC, A2LA, NIST                            EMC, RF/Wireless , Telecom
              Taiwan                       BSMI , NCC , NIST                            EMC, RF, Telecom , Safety
             Hong Kong                         OFTA , NIST                                  RF/Wireless ,Telecom
              Australia                        NATA, NIST                               EMC, RF, Telecom , Safety
               Korea                        KCC/RRA, NIST                            EMI, EMS, RF , Telecom, Safety
               Japan                     VCCI, JATE, TELEC, RFT                         EMI, RF/Wireless, Telecom
               Mexico                    NOM, COFETEL, Caniety                      Safety, EMC , RF/Wireless, Telecom
              Europe                            A2LA, NIST                              EMC, RF, Telecom , Safety


                                     Accreditations for Product Certifications
               Country                      Accreditation Body                                    Scope
                 USA                         FCC TCB, NIST                                  EMC , RF , Telecom
               Canada                         IC FCB , NIST                                 EMC , RF , Telecom
              Singapore                         iDA, NIST                                   EMC , RF , Telecom
                 EU                                 NB                                     EMC & R&TTE Directive
                Japan                         MIC (RCB 208)                                    RF , Telecom
              HongKong                        OFTA (US002)                                     RF , Telecom




          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                                                       Test report No.             FCC_RF_SL13092401-AVE-031_WLAN Rev1.0
                                                                                       Page                        3 of 26



CONTENTS
1      REPORT REVISION HISTORY ......................................................................................................................................... 4
2      EXECUTIVE SUMMARY ................................................................................................................................................... 5
3      CUSTOMER INFORMATION ............................................................................................................................................ 5
4      TEST SITE INFORMATION .............................................................................................................................................. 5
5      MODIFICATION ............................................................................................................................................................... 5
6      EUT INFORMATION......................................................................................................................................................... 6
     6.1    EUT Description .......................................................................................................................................................... 6
     6.2    Radio Description ........................................................................................................................................................ 7
     6.3    EUT test modes/configuration Description ..................................................................................................................... 8
     6.4    EUT Photos - External ................................................................................................................................................. 9
     6.5    EUT Photos - Internal ................................................................................................................................................ 10
     6.6    Host Photos - External ............................................................................................................................................... 11
     6.7    EUT Test Setup Photos ............................................................................................................................................. 12
7      SUPPORTING EQUIPMENT/SOFTWARE AND CABLING DESCRIPTION ........................................................................ 13
     7.1    Supporting Equipment ............................................................................................................................................... 13
     7.2    Test Software Description .......................................................................................................................................... 13
8      TEST SUMMARY ........................................................................................................................................................... 14
9      MEASUREMENT UNCERTAINTY ................................................................................................................................... 15
10          MEASUREMENTS, EXAMINATION AND DERIVED RESULTS ................................................................................... 16
     10.1       Conducted Emissions ............................................................................................................................................ 16
     10.2       Radiated Emissions below 1GHz............................................................................................................................ 19
     10.3       Radiated Spurious Emissions above 1GHz ............................................................................................................. 21
ANNEX A. TEST INSTRUMENT ............................................................................................................................................. 23
ANNEX B. USER MANUAL, BLOCK & CIRCUIT DIAGRAM .................................................................................................... 24
ANNEX C. SIEMIC ACCREDITATION ..................................................................................................................................... 25




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                           Visit us at: www.siemic.com; Follow us at:


                                                            Test report No.   FCC_RF_SL13092401-AVE-031_WLAN Rev1.0
                                                            Page              4 of 26




1     Report Revision History

                  Report No.                           Report Version              Description             Issue Date
       FCC_RF_SL13092401-AVE-031_WLAN                      None                      Original               1/6/2014
    FCC_RF_SL13092401-AVE-031_WLAN Rev1.0                 Rev1.0                Update EUT model            7/18/2014




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:


                                                            Test report No.   FCC_RF_SL13092401-AVE-031_WLAN Rev1.0
                                                            Page              5 of 26




2    Executive Summary

The purpose of this test program was to demonstrate compliance of following product
 Company:        Avery Dennison
 Product:        SDIO Wireless Module
 Model:          SX-SDMAN

, which is FCC certified radio module (FCC ID: GU6-SDMAN, IC ID: 1502A-SDMAN), to be installed into a printer host
(Printer Model: ADTP1, ADTP1CT, ADTP1CR) and simultaneously transmission with FCC certified RFID radio module
(FCC ID: GU6-RS500GX, IC ID: 1502A-RS500GX), against the current Stipulated Standards. The specified model
product stated above has demonstrated compliance with the Stipulated Standard listed on 1st page.


3    Customer information

 Applicant Name                          Avery Dennison
 Applicant Address                       170 Monarch Lane,Miamisburg, OH, 45342
 Manufacturer Name                       Avery Dennison
 Manufacturer Address                    170 Monarch Lane,Miamisburg, OH, 45342




4    Test site information

 Lab performing tests                    SIEMIC Laboratories
 Lab Address                             775 Montague Expressway, Milpitas, CA 95035
 FCC Test Site No.                       881796
 IC Test Site No.                        4842D-2
 VCCI Test Site No.                      A0133



5    Modification


                 Index                           Item                         Description                     Note
                    -                              -                               -                            -




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:


                                                             Test report No.   FCC_RF_SL13092401-AVE-031_WLAN Rev1.0
                                                             Page              6 of 26




6     EUT Information

6.1    EUT Description


 Product Name                             SDIO Wireless Module
 Model No.                                SX-SDMAN
 Trade Name                               Monarch / Avery Dennison
 Serial No.                               N/A
 Input Power                              3.3 VDC
 Power Adapter Manu/Model                 N/A
 Power Adapter SN                         -
 Hardware version                         N/A
 Software version                         N/A
 Date of EUT received                     11/18/2013
 Equipment Class/ Category                DTS, UNII
 Clock Frequencies                        2.4GHz, 5GHz band
 Port/Connectors                          SDIO
                                          ADTP1 - Basic model with 140W power supply
                                          ADTP1CT - Extended model with 300W power supply that allows
                                          cutter to be added.
                                          ADTP1CR - DC version (Cart Ready)
                                          The testing was performed on ADTP1 as the worst case
 Remark                                   representative.




          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                              Visit us at: www.siemic.com; Follow us at:


                                                              Test report No.          FCC_RF_SL13092401-AVE-031_WLAN Rev1.0
                                                              Page                     7 of 26




6.2     Radio Description

Spec for Radio -
       Radio Type                802.11b              802.11g                   802.11a         802.11n-20M        802.11n-40M
                                                                                               2412-2462MHz
                                                                        5180-5320MHz                              5190-5310MHz
                                                                                               5180-5320MHz
 Operating Frequency         2412-2462MHz         2412-2462MHz          5470-5725MHz                              5510-5670MHz
                                                                                               5470-5725MHz
                                                                        5725-5825MHz                              5755-5795MHz
                                                                                               5725-5825MHz
                                                   OFDM-CCK              OFDM (BPSK,           OFDM (BPSK,        OFDM (BPSK,
                                 DSSS
                                                  (BPSK, QPSK,              QPSK,                  QPSK,             QPSK,
        Modulation           (CCK, DQPSK,
                                                     16QAM,                16QAM,                 16QAM,            16QAM,
                                DBPSK)
                                                    64QAM)                 64QAM)                 64QAM)            64QAM)
                                                                                               5MHz(2.4GHz),
      Channel Spacing             5MHz                 5MHz                     20MHz                                40MHz
                                                                                               20MHz (5GHz)
                                                                                                 11(2.4GH)          7 (2.4GH)
  Number of Channels                11                   11                       21
                                                                                                 21 (5GHz)          9 (5GHz)
     Antenna Type            Sleeve antenna: Sansei
     Antenna Gain            Sleeve antenna: 1.0 dBi (2.4GHz), 1.1 dBi (5GHz)
Antenna Connector Type       U.FL connector




          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                              Visit us at: www.siemic.com; Follow us at:


                                                           Test report No.   FCC_RF_SL13092401-AVE-031_WLAN Rev1.0
                                                           Page              8 of 26


6.3   EUT test modes/configuration Description

Test mode


                                        Final Test Mode                                                       Note
 Final_test_mode_1           Below 1GHz-Mode1:UHF RFID hopping + WLAN @ 802.11b-2437MHz                        -
 Final_test_mode_2           Above 1GHz-Mode1: UHF RFID hopping + WLAN @ 802.11b-2437MHz                       -
 Final_test_mode_3                                                                                             -
 Final_test_mode_4                                                                                             -
 Final_test_mode_5                                                                                             -
 Final_test_mode_6                                               -                                             -
 Final_test_mode_7                                               -                                             -
 Final_test_mode_8                                               -                                             -
 Final_test_mode_9                                               -                                             -
 Remark:




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                            Visit us at: www.siemic.com; Follow us at:


                                                          Test report No.   FCC_RF_SL13092401-AVE-031_WLAN Rev1.0
                                                          Page              9 of 26


6.4   EUT Photos - External




                   EUT – Top View                                                 EUT – Bottom View




                 Antenna – Top View                                              Antenna – Port View




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                           Visit us at: www.siemic.com; Follow us at:


                                                          Test report No.   FCC_RF_SL13092401-AVE-031_WLAN Rev1.0
                                                          Page              10 of 26


6.5   EUT Photos - Internal




                 Radio module – Top                                             Radio module – Bottom




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                           Visit us at: www.siemic.com; Follow us at:


                                                          Test report No.   FCC_RF_SL13092401-AVE-031_WLAN Rev1.0
                                                          Page              11 of 26


6.6   Host Photos - External




                    Top Side View                                                  Bottom Side View




                Front Side View Side                                                Rear View Side




                    Left Side View                                                 Right Side View




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                           Visit us at: www.siemic.com; Follow us at:


                                                          Test report No.       FCC_RF_SL13092401-AVE-031_WLAN Rev1.0
                                                          Page                  12 of 26


6.7   EUT Test Setup Photos




       Radiated Emissions (<1GHz) – Front View                              Radiated Emissions (<1GHz) – Rear View




       Radiated Emissions (>1GHz) – Front View                              Radiated Emissions (>1GHz) – Rear View




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                           Visit us at: www.siemic.com; Follow us at:


                                                               Test report No.    FCC_RF_SL13092401-AVE-031_WLAN Rev1.0
                                                               Page               13 of 26




7     Supporting Equipment/Software and cabling Description

7.1        Supporting Equipment

                Supporting Equipment
    Item                                           Model            Serial Number           Manufacturer         Note
                    Description
      1                 D600                   Laptop PC             9444352681                   Dell
                                               AC Power
      2              PA-1650-05D2                                        F7970                    Dell
                                                Adapter




7.2        Test Software Description


      Test Item                         Software                                    Description
          -                                 -                                           -




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                             Test report No.      FCC_RF_SL13092401-AVE-031_WLAN Rev1.0
                                                             Page                 14 of 26




8     Test Summary
                                                     Spurious Emissions
              Test Item                    Test standard                   Test Method/Procedure              Pass / Fail
                                             15.207(a)                         ANSI C63.4 – 2009           ☒ Pass ☐ Fail
    AC Conducted Emissions Voltage
                                          RSS Gen (7.2.2)                RSS-Gen Issue 3: 2010             ☒ Pass ☐ Fail
                                                                           ANSI C63.4: 2009
                                            FCC-15.247                                                     ☒ Pass ☐ Fail
Radiated Spurious Emissions<1GHz                                  558074 D01 DTS Meas Guidance v03r01
                                            IC-RSS 210                   RSS-Gen Issue 3: 2010             ☒ Pass ☐ Fail
                                                                           ANSI C63.4: 2009
                                            FCC-15.247                                                     ☒ Pass ☐ Fail
Radiated Spurious Emissions>1GHz                                  558074 D01 DTS Meas Guidance v03r01
                                            IC-RSS 210                   RSS-Gen Issue 3: 2010             ☒ Pass ☐ Fail




          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                              Visit us at: www.siemic.com; Follow us at:


                                                             Test report No.     FCC_RF_SL13092401-AVE-031_WLAN Rev1.0
                                                             Page                15 of 26




9    Measurement Uncertainty


                                                          Emissions
                                                                                                                         Uncertain
         Test Item              Frequency Range                                Description
                                                                                                                            ty
                                                        Confidence level of approximately 95% (in the case where
    Conducted Emissions         150KHz – 30MHz                                                                            ±3.5dB
                                                            distributions are normal), with a coverage factor of 2
                                                        Confidence level of approximately 95% (in the case where
                                                                                                                         +5.6dB/-
Radiated Spurious Emissions       30MHz – 1GHz        distributions are normal), with a coverage factor of 2 (for EUTs
                                                                                                                          4.5dB
                                                                            < 0.5m X 0.5m X 0.5m)
                                                        Confidence level of approximately 95% (in the case where
                                                                                                                         +4.3dB/-
Radiated Spurious Emissions       1GHz – 40GHz        distributions are normal), with a coverage factor of 2 (for EUTs
                                                                                                                          4.1dB
                                                                            < 0.5m X 0.5m X 0.5m)




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                              Visit us at: www.siemic.com; Follow us at:


                                                                 Test report No.        FCC_RF_SL13092401-AVE-031_WLAN Rev1.0
                                                                 Page                   16 of 26




10 Measurements, Examination and Derived Results

10.1 Conducted Emissions

Conducted Emission Limit
                                      Frequency ranges                                         Limit (dBuV)
                                           (MHz)                                   QP                             Average
                                          0.15 ~ 0.5                           66 – 56                            56 – 46
                                            0.5 ~ 5                              56                                 46
                                            5 ~ 30                               60                                 50


 Spec                Item     Requirement                                                                               Applicable
                     a)       For Low-power radio-frequency devices that is designed to be connected to the             ☒
                              public utility (AC) power line, the radio frequency voltage that is conducted back onto
 47CFR§15.207,                the AC power line on any frequency or frequencies, within the band 150 kHz to 30
  RSS210(A8.1)                MHz, shall not exceed the limits in the following table, as measured using a 50
                              [mu]H/50 ohms line impedance stabilization network (LISN). The lower limit applies
                              at the boundary between the frequency ranges.




   Test Setup




                          -    The EUT and supporting equipment were set up in accordance with the requirements of the standard on
                               top of a 1.5m x 1m x 0.8m high, non-metallic table, as shown in Annex B.
   Procedure              -    The power supply for the EUT was fed through a 50/50H EUT LISN, connected to filtered mains.
                          -    The RF OUT of the EUT LISN was connected to the EMI test receiver via a low-loss coaxial cable.
                          -    All other supporting equipment were powered separately from another main supply.

     Remark          NONE


     Result          ☒ Pass             ☐ Fail



Test Data      ☒ Yes                        ☐ N/A
Test Plot      ☒ Yes (See below)            ☐ N/A




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                 Visit us at: www.siemic.com; Follow us at:


                                                          Test report No.   FCC_RF_SL13092401-AVE-031_WLAN Rev1.0
                                                          Page              17 of 26




Conducted Emission Test Results (AC Line Test Result)

                                               Temp (°C):                   21
           Environmental Conditions:           Humidity (%)                 44
                                               Atmospheric (mPa):
                                                                                                         Result
                 Mains Power:                  120 VAC/ 60Hz/ Live Line
                  Tested by:                   David Zhang
                  Test Date:                   31-Dec-13
                  Remarks:                     With host ADTP1




    Frequency     Raw      Cable Factors         Level      Measurement               Limit     Margin        Pass
                                                                             Line
       MHz        dBuV     Loss    dB            dBuV          Type                   dBuV       dB           /Fail
      3.190       37.64    10.03        1        48.67       Quasi Peak      Live       56       -7.33        Pass
      3.259       37.57    10.03       1.01      48.61       Quasi Peak      Live       56       -7.39        Pass
      3.122       34.81    10.03       0.99      45.83       Quasi Peak      Live       56      -10.17        Pass
      3.398       32.23    10.03       1.02      43.28       Quasi Peak      Live       56      -12.72        Pass
      3.329       35.09    10.03       1.01      46.13       Quasi Peak      Live       56       -9.87        Pass
      3.051       30.83    10.03       0.98      41.84       Quasi Peak      Live       56      -14.16        Pass
      3.190       34.54    10.03        1        45.57         Average       Live       46       -0.43        Pass
      3.259       33.56    10.03       1.01      44.59         Average       Live       46       -1.41        Pass
      3.122       32.12    10.03       0.99      43.14         Average       Live       46       -2.86        Pass
      3.398       29.47    10.03       1.02      40.52         Average       Live       46       -5.48        Pass
      3.329       31.84    10.03       1.01      42.88         Average       Live       46       -3.12        Pass
      3.051       30.61    10.03       0.98      41.62         Average       Live       46       -4.38        Pass




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                           Visit us at: www.siemic.com; Follow us at:


                                                      Test report No.    FCC_RF_SL13092401-AVE-031_WLAN Rev1.0
                                                      Page               18 of 26




                                           Temp (°C):                    21
      Environmental Conditions:            Humidity (%)                  44
                                           Atmospheric (mPa):
                                                                                                     Result
            Mains Power:                   120 VAC/ 60Hz/ Neutral Line
              Tested by:                   David Zhang
              Test Date:                   31-Dec-13
              Remarks:                     With host ADTP1




Frequency    Raw       Cable Factors        Level        Measurement               Limit    Margin        Pass
                                                                          Line
   MHz       dBuV      Loss    dB           dBuV            Type                   dBuV      dB           /Fail
  3.192       31.39    10.03       1        42.41         Quasi Peak     Neutral    56      -13.59        Pass
  3.122       28.79    10.03      0.99      39.81         Quasi Peak     Neutral    56      -16.19        Pass
  3.259       31.39    10.03      1.01      42.42         Quasi Peak     Neutral    56      -13.58        Pass
  3.398       27.14    10.03      1.02      38.19         Quasi Peak     Neutral    56      -17.81        Pass
  3.331       28.43    10.03      1.01      39.47         Quasi Peak     Neutral    56      -16.53        Pass
  3.061       27.95    10.03      0.99      38.96         Quasi Peak     Neutral    56      -17.04        Pass
  3.192       27.77    10.03       1         38.8          Average       Neutral    46       -7.2         Pass
  3.122       24.91    10.03      0.99      35.93          Average       Neutral    46      -10.07        Pass
  3.259       27.2     10.03      1.01      38.23          Average       Neutral    46       -7.77        Pass
  3.398       23.75    10.03      1.02       34.8          Average       Neutral    46       -11.2        Pass
  3.331       26.16    10.03      1.01       37.2          Average       Neutral    46       -8.8         Pass
  3.061       24.91    10.03      0.99      35.92          Average       Neutral    46      -10.08        Pass




   775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                       Visit us at: www.siemic.com; Follow us at:


                                                                  Test report No.      FCC_RF_SL13092401-AVE-031_WLAN Rev1.0
                                                                  Page                 19 of 26


10.2 Radiated Emissions below 1GHz

Requirement(s):
 Spec                   Item   Requirement                                                                                Applicable
                        a)
                               Except higher limit as specified elsewhere in other section, the emissions from the        ☒
                               low-power radio-frequency devices shall not exceed the field strength levels
                               specified in the following table and the level of any unwanted emissions shall not
                               exceed the level of the fundamental emission. The tighter limit applies at the band
 47CFR§15.247(d),              edges
   RSS210(A8.5)
                                         Frequency range (MHz)                        Field Strength (uV/m)
                                                30 – 88                                        100
                                                88 – 216                                       150
                                                216 960                                        200
                                               Above 960                                       500




    Test Setup




                        1.        The EUT was switched on and allowed to warm up to its normal operating condition.
                        2.        The test was carried out at the selected frequency points obtained from the EUT characterisation.
                                  Maximization of the emissions, was carried out by rotating the EUT, changing the antenna
                                  polarization, and adjusting the antenna height in the following manner:
                                  a.         Vertical or horizontal polarisation (whichever gave the higher emission level over a full
    Procedure                                rotation of the EUT) was chosen.
                                  b.         The EUT was then rotated to the direction that gave the maximum emission.
                                  c.         Finally, the antenna height was adjusted to the height that gave the maximum emission.
                        3.        A Quasi-peak measurement was then made for that frequency point.
                        4.        Steps 2 and 3 were repeated for the next frequency point, until all selected frequency points were
                                  measured.

        Remark          NONE


        Result          ☒ Pass            ☐ Fail


Test Data      ☒ Yes (See below)            ☐ N/A


Test Plot     ☒ Yes (See below)             ☐ N/A




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                 Visit us at: www.siemic.com; Follow us at:


                                                                 Test report No.       FCC_RF_SL13092401-AVE-031_WLAN Rev1.0
                                                                 Page                  20 of 26


Radiated Emission Test Results (Below 1GHz)

             Test specification                  below 1GHz
                                                 Temp (°C):                            18.9
       Environmental Conditions:                 Humidity (%)                           22
                                                 Atmospheric (mPa):
              Mains Power:                       110VAC, 60Hz                                         Result           PASS
               Tested by:                        Teody Manansala
               Test Date:                        9-Dec-13
                                                 Avery ADTP1, RFID + WLAN TX
                 Remarks:
                                                 simultaneously




 Frequency       Raw        Cable                   Level      Measurement                Hgt   Azt       Limit   Margin       Pass
                                        AF dB                                      Pol
    MHz          dBuV       Loss                   dBuV/m         Type                    cm    Deg      dBuV/m    dB          /Fail
   78.541        42.23      1.36        -18.43      25.17        Quasi Max         V      113   189        40      -14.83      Pass
   700.01        34.05      4.67         -6.77      31.95        Quasi Max         V      100    3         46      -14.05      Pass
   77.813        34.23      1.35        -18.35      17.23        Quasi Max         H      196   189        40      -22.77      Pass
   106.18        36.33      1.73        -14.62      23.44        Quasi Max         V      197   213       43.5     -20.06      Pass
   384.05        39.31      3.36        -12.27      30.41        Quasi Max         V      100   231        46      -15.59      Pass
   120.75        38.47      1.88        -12.53      27.82        Quasi Max         H      184   105       43.5     -15.68      Pass




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                  Visit us at: www.siemic.com; Follow us at:


                                                                     Test report No.      FCC_RF_SL13092401-AVE-031_WLAN Rev1.0
                                                                     Page                 21 of 26




10.3 Radiated Spurious Emissions above 1GHz
Requirement(s):
   Spec                   Item        Requirement                                                                          Applicable
                                                                                                                           ☒
                                      For non-restricted band, In any 100 kHz bandwidth outside the frequency
                                      band in which the spread spectrum or digitally modulated intentional radiator
                                      is operating, the radio frequency power that is produced by the intentional
                                      radiator shall be at least 20 dB or 30dB below that in the 100 kHz bandwidth
                               a)
                                      within the band that contains the highest level of the desired power,
   47CFR§15.247(d),
                                      determined by the measurement method on output power to be used.
     RSS210(A8.5)
                                      Attenuation below the general limits specified in § 15.209(a) is not required
                                       ☒ 20 dB down           ☐ 30 dB down
                                                                                                                           ☒
                                      or restricted band, emission must also comply with the radiated emission
                               b)
                                      limits specified in 2.8




       Test Setup




                          1.           The EUT was switched on and allowed to warm up to its normal operating condition.
                          2.           The test was carried out at the selected frequency points obtained from the EUT
                                       characterisation. Maximization of the emissions, was carried out by rotating the EUT, changing
                                       the antenna polarization, and adjusting the antenna height in the following manner:
                                       a.        Vertical or horizontal polarisation (whichever gave the higher emission level over a full
       Procedure                                 rotation of the EUT) was chosen.
                                       b.        The EUT was then rotated to the direction that gave the maximum emission.
                                       c.        Finally, the antenna height was adjusted to the height that gave the maximum
                                                 emission.
                          3.           An average measurement was then made for that frequency point.
                          4.           Steps 2 and 3 were repeated for the next frequency point, until all selected frequency points
                                       were measured.
          Remark          None

            Result        ☒ Pass               ☐ Fail


Test Data      ☒ Yes (See below)              ☐ N/A


Test Plot      ☐ Yes (See below)              ☒ N/A




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                    Visit us at: www.siemic.com; Follow us at:


                                                             Test report No.    FCC_RF_SL13092401-AVE-031_WLAN Rev1.0
                                                             Page               22 of 26




Radiated Emission Test Results (Above 1GHz)
Above 1GHz-25GHz- Mode1: RFI UHF RFID hopping + Silex WLAN module @ 802.11b-2437MHz simultaneously
                     Cabl             Level
 Frequency   Raw                                Measuremen           Hgt      Azt      Limit       Margin           Pass
                      e      AF dB    dBuV/                  Pol
    MHz      dBuV                                  t Type            cm       Deg     dBuV/m        dB              /Fail
                     Loss               m
 4513.711    64.25     2.46       -0.27     66.44       Peak Max        V      122     156       74        -7.56    Pass
 9300.653    45.33     3.39       6.23      54.95       Peak Max        H      182     202       74        -19.05   Pass
 1535.595    62.68     1.17       -6.14     57.71       Peak Max        V      129     325       74        -16.29   Pass
 1327.026    48.48     1.02       -6.55     42.95       Peak Max        H      188     77        74        -31.05   Pass
 4513.711    50.24     2.46       -0.27     52.43     Average Max       V      122     156       54        -1.57    Pass
 9300.653    32.99     3.39       6.23      42.61     Average Max       H      182     202       54        -11.39   Pass
1535.5952    58.43     1.17       -6.14     53.46     Average Max       V      129     325       54        -0.54    Pass
 1327.026    31.75     1.02       -6.55     26.21     Average Max       H      188     77        54        -27.79   Pass




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                              Visit us at: www.siemic.com; Follow us at:


                                                              Test report No.     FCC_RF_SL13092401-AVE-031_WLAN Rev1.0
                                                              Page                23 of 26




Annex A. TEST INSTRUMENT

         Instrument                        Model               Serial #         Cal Date     Cal Cycle    Cal Due     In use

    Conducted Emissions
        R & S Receiver                     ESIB 40             100179           04/20/2013    1 Year     04/20/2014
          R&S LISN                        ESH2-Z5            861741/013         05/18/2013    1 Year     05/18/2014
         CHASE LISN                       MN2050B               1018            07/24/2013    1 Year     07/24/2014
  Sekonic Hygro Hermograph                  ST-50           HE01-000092         05/25/2013    1 Year     05/25/2014
     Radiated Emissions
        R & S Receiver                      ESL6               100178           03/01/2013    1 Year     03/01/2014
        R & S Receiver                     ESIB 40             100179           04/20/2013    1 Year     04/20/2014
  ETS-Lingren Loop Antenna                  6512              00049120          05/13/2013    1 Year     05/13/2014
 Bi-Log antenna (30MHz~2GHz)                 JB1              A030702           02/09/2013    1 Year     02/09/2014
   Horn Antenna (1-26.5GHz)                 3115              10SL0059          04/26/2013    1 Year     04/26/2014
   Horn Antenna (18-40 GHz)                AH-840              101013           04/23/2013    1 Year     04/23/2014
   Pre-Amplifier (1-26.5GHz)               8449B            3008A00715          05/30/2013    1 Year     05/30/2014
 Microwave Preamplifier (18-40
                                           PA-840              181251           05/30/2013    1 Year     05/30/2014
            GHz)
        3 Meters SAC                         3M                  N/A            10/13/2013    1 Year     10/13/2014
        10 Meters SAC                       10M                  N/A            06/05/2013    1 Year     06/05/2014
  Sekonic Hygro Hermograph                  ST-50           HE01-000092         05/25/2013    1 Year     05/25/2014
 RF Conducted Measurement
      Spectrum Analyzer                    N9010A           MY50210206          05/30/2013    1 Year     05/30/2014
      Spectrum Analyzer                    E4407B           US88441016          05/31/2013    1 Year     05/31/2014
        R & S Receiver                     ESIB 40             100179           04/20/2013    1 Year     04/20/2014




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                               Visit us at: www.siemic.com; Follow us at:


                                                        Test report No.   FCC_RF_SL13092401-AVE-031_WLAN Rev1.0
                                                        Page              24 of 26




Annex B. USER MANUAL, BLOCK & CIRCUIT DIAGRAM
                                               Please see attachment




     775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                         Visit us at: www.siemic.com; Follow us at:


                                                               Test report No.     FCC_RF_SL13092401-AVE-031_WLAN Rev1.0
                                                               Page                25 of 26




Annex C. SIEMIC Accreditation


        Accreditations         Document                                          Scope / Remark

ISO 17025 (A2LA)                           Please see the documents for the detailed scope

ISO Guide 65 (A2LA)                        Please see the documents for the detailed scope

TCB Designation                            A1, A2, A3, A4, B1, B2, B3, B4, C

FCC DoC Accreditation                      FCC Declaration of Conformity Accreditation

FCC Site Registration                      3 meter site

FCC Site Registration                      10 meter site

IC Site Registration                       3 meter site

IC Site Registration                       10 meter site

                                           Radio & Telecommunications Terminal Equipment:
                                           EN45001 – EN ISO/IEC 17025
EU NB
                                           Electromagnetic Compatibility:
                                           EN45001 – EN ISO/IEC 17025

Singapore iDA
                                           Phase I, Phase II
CB(Certification Body)

Vietnam MIC
                                           Please see the document for the detailed scope
CAB Accreditation

                                           (Phase II) OFCA Foreign Certification Body for Radio and Telecom
HongKong OFCA
                                           (Phase I) Conformity Assessment Body for Radio and Telecom

                                           Radio: Scope A – All Radio Standard Specification in Category I
Industry Canada CAB
                                           Telecom: CS-03 Part I, II, V, VI, VII, VIII




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:


                                                            Test report No.    FCC_RF_SL13092401-AVE-031_WLAN Rev1.0
                                                            Page               26 of 26




                                           Radio : A1. Terminal equipment for purpose of calling
Japan Recognized Certification
                                           Telecom : B1. Specified radio equipment specified in Article 38-2, Paragraph 1, Item
Body Designation
                                           1 of the Radio Law

                                           EMI: KCC Notice 2008-39, RRL Notice 2008-3: CA Procedures for EMI
                                           KN22: Test Method for EMIEMS: KCC Notice 2008-38, RRL Notice 2008-4: CA
                                           Procedures for EMS
                                           KN24, KN61000-4-2, -4-3, -4-4, -4-5, -4-6, -4-8, -4-11: Test Method for EMS

Korea CAB Accreditation                    Radio: RRL Notice 2008-26, RRL Notice 2008-2, RRL Notice 2008-10,
                                           RRL Notice 2007-49, RRL Notice 2007-20, RRL Notice 2007-21, RRL Notice 2007-
                                           80, RRL Notice 2004-68

                                           Telecom: President Notice 20664, RRL Notice 2007-30, RRL Notice 2008-7 with
                                           attachments 1, 3, 5, 6; President Notice 20664, RRL Notice 2008-7 with attachment 4

                                           LP0002, PSTN01, ADSL01, ID0002, IS6100, CNS14336, PLMN07, PLMN01,
Taiwan NCC CAB Recognition
                                           PLMN08

Taiwan BSMI CAB Recognition                CNS 13438

                                           R-3083: Radiation 3 meter site
Japan VCCI                                 C-3421: Main Ports Conducted Interference Measurement
                                           T-1597: Telecommunication Ports Conducted Interference Measuremet

                                           EMC: AS/NZS CISPR 11, AS/NZS CISPR 14.1, AS/NZS CISPR22, AS/NZS
                                           61000.6.3, AS/NZS 61000.6.4

                                           Radiocommunications: AS/NZS 4281, AS/NZS 4268, AS/NZS 4280.1,
                                           AS/NZS 4280.2, AS/NZS 4295, AS/NZS 4582, AS/NZS 4583, AS/NZS 4769.1,
Australia CAB Regocnition
                                           AS/NZS 4769.2, AS/NZS 4770, AS/NZS 4771

                                           Telecommunications: AS/ACIF S002:05, AS/ACIF S003:06, AS/ACIF S004:06
                                           AS/ACIF S006:01, AS/ACIF S016:01, AS/ACIF S031:01, AS/ACIF S038:01,
                                           AS/ACIF S040:01, AS/ACIF S041:05, AS/ACIF S043.2:06, AS/ACIF S60950.1

                                           AS/ACIF S002, AS/ACIF S003, AS/ACIF S004, AS/ACIF S006, AS/ACIF
Australia NATA Recognition                 S016,AS/ACIF S031, AS/ACIF S038, AS/ACIF S040, AS/ACIF S041, AS/ACIF
                                           S043.2




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:



Document Created: 2014-07-18 16:26:56
Document Modified: 2014-07-18 16:26:56

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC