operational description

FCC ID: GQ4-56T

Operational Description

Download: PDF
FCCID_1686945

                                                              TRW Automotive


March 16, 2012                                                TEE
                                                              24175 Research Dr.
                                                              Farmington Hills, MI 48335-2642
                                                              Tel 248.478.7210
                                                              Fax 248.699.4241




RE:     Certification for HKMC MY2012.5 YD/QD 315MHz TPM Sensor
        Model #:           225816-116
        FCC ID:            GQ4-56T
        Canada IC:         1470A-37T


GENERAL DESCRIPTION

This device is a transmitter/sensor with tire valve, which is mounted in the valve hole of the rim and measures the
pressure inside the tire, as well as if the vehicle is in motion. These measurements are then transmitted over Radio
Frequency (RF) to a receiver also located in the vehicle. The device also has a Low Frequency (LF) receiver. This
receiver supports Low Frequency (LF) magnetic field communications allowing the changing of
measurement/monitoring states of the transmitter by commands sent via the TPM diagnostic tool. The RF signal
operates at 315MHz and uses FSK Manchester code modulation.


                                            Description of Operation

                       Sensor                                                   Frequency of
                                                   Description
                     State/Mode                                                 Transmission
                  Storage               Measures pressure.                    Single 8-Frame
                                                                              TPS Message upon
                                                                              LF request.
                  Sleep                 Measures pressure and motion.         Single 8-Frame
                                                                              TPS Message upon
                                                                              LF request.
                  Motion                Measures pressure and motion.         Single 8-Frame
                                        Transmits periodically.               TPS Message at 16
                                                                              second intervals for
                                                                              1st minute after
                                                                              exiting Sleep State
                                                                              and then at 1
                                                                              minute intervals or
                                                                              upon LF request.
                  Motion Alert          Measures pressure.                    1 minute period of
                                         Transmits when:                      4 second interval 8-
                                        a) significant pressure delta         Frame TPS
                                        detected                              Messages
                  Sleep Alert           Measures pressure and                 5 second cycle of
                                        temperature.                          200ms period,
                                         Transmits when:                      50% duty cycle
                                        a) significant pressure delta         Single-Frame TPS
                                        detected with change in pressure      Message
                                        to temperature ratio
                  Rest                  Measures pressure and motion.         Single 8-Frame
                                                                              TPS Message upon
                                                                              LF request.