GENERAL DESCRIPTION

This transmitter is a transmitter device with tire valve, which is mounted in the valve hole of the wheel rim and
transmits the pressure and temperature inside the tire, the battery voltage of the transmitter, and the tire identification
code (ID) at normal and abnormal condition with the radio wave (RF) that conforms to the used area. Also this
device has a countermeasure function such as the random delay of transmission time so that the RF signal from each
tire will not interfere due to the simultaneous transmission. The transmitter device also has a Low Frequency (LF)
receiver. This receiver supports Low Frequency (LF) magnetic field communications allowing the changing of
measurement/monitoring states of the transmitter by commands sent via the TPM diagnostic tool. The RF signal
operates at 315MHz and uses FSK Manchester code modulation.



                                              Description of Operations



   Mode of
                                         Explanation                                  Frequency of Transmission
  Operation

                                                                               4 words when activation occurs with
Storage Mode       No transmission. Measures temperature & pressure
                                                                               TPM diagnostic tool
                   Measures temperature and pressure. Transmits                    4 words every 210 seconds
Normal Mode        periodically. Enters this mode from storage when                4 words when activation occurs
                   pressure goes above threshold.                                   with TPM diagnostic tool

                   Transmits when:
Alert Mode         a) significant pressure delta detected                      8 words every 4 seconds for 1 minute
                   b) high temperature is detected