Revised Test Report

FCC ID: G8JVRT02

Test Report

Download: PDF
FCCID_301082

                                       Engineering and Testing for EMC and Safety Compliance

                            CERTIFICATION APPLICATION REPORT FCC PART 15.231

Test Lab:
                                                                    Applicant Information:
Rhein Tech Laboratories, Inc. Phone:703-689-0368
                                                                    AMCO Automated Systems          Phone: 304-757-3300
360 Herndon Parkway           Fax: 703-689-2056
                                                                    Contact: Eric Kiser             Fax:    304-757-3388
Suite 1400                    Web Site: www.rheintech.com
                                                                    107 Erskine Lane                 E-Mail: ekiser@amcoas.com
Herndon, VA 20170
                                                                    Scott Depot, WV 25560
E-Mail : ATCBINFO@rheintech.com

FCC ID:                       G8JVRT02                              GRANTEE FRN NUMBER:                     0007856438
PLAT FORM:                    N/A                                   RTL WORK ORDER NUMBER:                  2002199
                              Remote Water Meter Transponder
MODEL(S):                                                           RTL QUOTE NUMBER:                       QRTL02-632
                              (RWT)
TEST REPORT DATE:             December 23, 2002

American National
                              ANSI/TIA/EIA603 and ANSI/TIA/EIA 603-1
Standard Institute:
FCC Classification:           Low Power Communication Device Transmitter

FCC Rule Part(s):             Part 15.231 Periodic operation in the band 40.66-40.70 MHz and above 70 MHz

Digital Interface
                              Digital Interface was found to be compliant
Information
Receiver Information          Receiver was found to be compliant

   We, the undersigned, hereby declare that the equipment tested and referenced in this report conforms to the identified
   standard(s) as described in this test report. No modifications were made to the equipment during testing in order to achieve
   compliance with these standards.

   Furthermore, there was no deviation from, additions to, or exclusions from the FCC Part 2, FCC Part 15, ANSI/TIA/EIA
   603, and ANSI/TIA/EIA 603-1.


   Signature:                                                               Date:              December 23, 2002

   Typed/Printed Name: Desmond A. Fraser                                    Position:          President




                                               360 Herndon Parkway, Suite 1400
                                                     Herndon, VA 20170
                                 Phone: 703-689-0368; Fax: 703-689-2056; Metro: 703-471-6441


    Rhein Tech Laboratories                                                                                                                              AMCO Automated Systems
    360 Herndon Parkway                                                                                                                                  Remote Water Meter Transponder (RWT)
    Suite 1400                                                                                                                                           FCC ID: G8JVRT02
    Herndon, VA 20170                                                                                                                                    FCC Part 15.231
    http://www.rheintech.com                                                                                                                             RTL WO# 2002199



                                                                                      TABLE OF CONTENTS

1       GENERAL INFORMATION ..................................................................................................................................................................................... 4
     1.1      SCOPE .................................................................................................................................................................................. 4
     1.2      TEST FACILITY .................................................................................................................................................................. 4
     1.3      RELATED SUBMITTAL(S)/GRANT(S)............................................................................................................................. 4
2       TEST INFORMATION.............................................................................................................................................................................................. 5
     2.1      TEST JUSTIFICATION ....................................................................................................................................................... 5
     2.2      EXERCISING THE EUT...................................................................................................................................................... 5
     2.3      CONFORMITY WITH 15.231 (E) ....................................................................................................................................... 5
     2.4      TEST RESULT SUMMARY ................................................................................................................................................ 7
     2.5      TEST SYSTEM DETAILS ................................................................................................................................................... 8
     2.6      CONFIGURATION OF TESTED SYSTEM........................................................................................................................ 9
3       RADIATED EMISSION - §15.231.......................................................................................................................................................................... 10
     3.1      RADIATED EMISSION LIMITS TEST PROCEDURE.................................................................................................... 10
     3.2      DUTY CYCLE.................................................................................................................................................................... 10
     3.3      RADIATED EMISSION LIMITS TEST DATA ................................................................................................................ 12
     3.4      TEST EQUIPMENT USED FOR TESTING ...................................................................................................................... 12
4       MODULATED BANDWIDTH - §15.231(C)............................................................................................................................................................ 13
     4.1      MODULATED BANDWIDTH TEST PROCEDURE ....................................................................................................... 13
     4.2      TEST EQUIPMENT USED FOR TESTING ...................................................................................................................... 13
     4.3      MODULATED BANDWIDTH TEST DATA .................................................................................................................... 13
5       CONCLUSION ....................................................................................................................................................................................................... 15


                                                                                              FIGURE INDEX

FIGURE 1:                WORST CASE CONFIGURATION OF SYSTEM UNDER TEST................................................................................ 9


                                                                                               TABLE INDEX

TABLE 2-1:                    TEST RESULT SUMMARY WITH FCC RULES AND REGULATIONS ............................................................... 7
TABLE 2-2:                    EQUIPMENT UNDER TEST (EUT) .......................................................................................................................... 8
TABLE 3-1:                    RADIATED EMISSIONS ......................................................................................................................................... 12
TABLE 3-2:                    RADIATED EMISSIONS SPURS/HARMONICS ................................................................................................... 12
TABLE 3-3:                    RADIATED SPURIOUS EMISSIONS TEST EQUIPMENT................................................................................... 12
TABLE 4-1:                    TEST EQUIPMENT USED FOR TESTING (MODULATED BANDWIDTH) ...................................................... 13
TABLE 4-2:                    MINIMUM 20 DB MODULATED BANDWIDTH ................................................................................................. 13

                                                                                                 PLOT INDEX

PLOT 2-1:                TIMING REQUIREMENT .............................................................................................................................................. 6
PLOT 3-1:                DUTY CYCLE PLOT .................................................................................................................................................... 11
PLOT 4-1:                MODULATED BANDWIDTH...................................................................................................................................... 14




                                                                                                                                                                                  Page 2 of 30


 Rhein Tech Laboratories                                                                                                     AMCO Automated Systems
 360 Herndon Parkway                                                                                                         Remote Water Meter Transponder (RWT)
 Suite 1400                                                                                                                  FCC ID: G8JVRT02
 Herndon, VA 20170                                                                                                           FCC Part 15.231
 http://www.rheintech.com                                                                                                    RTL WO# 2002199




                                                                      APPENDIX INDEX
APPENDIX A:        ANTENNA SPECIFICATIONS........................................................................................................................... 16
APPENDIX B:        AGENCY AUTHORIZATION LETTER............................................................................................................. 17
APPENDIX C:        CONFIDENTIALITY REQUEST LETTER ........................................................................................................ 18
APPENDIX D:        PRODUCT DESCRIPTION ................................................................................................................................. 19
APPENDIX E:        LABEL AND LABEL LOCATION ..................................................................................................................... 20
APPENDIX F:        SCHEMATICS ..................................................................................................................................................... 21
APPENDIX G:        BLOCK DIAGRAM ............................................................................................................................................. 22
APPENDIX H:        MANUAL............................................................................................................................................................. 23
APPENDIX I:        TEST PHOTOGRAPHS........................................................................................................................................ 24
APPENDIX J:        EXTERNAL PHOTOGRAPHS ............................................................................................................................ 26
APPENDIX K:        INTERNAL PHOTOGRAPHS............................................................................................................................. 28


                                                                  PHOTOGRAPH INDEX

PHOTOGRAPH 1:           ANTENNA LOCATION ................................................................................................................................. 16
PHOTOGRAPH 2:           LOCATION OF LABEL ON DEVICE ........................................................................................................... 20
PHOTOGRAPH 3:           RADIATED EMISSION FRONT VIEW, WORST CASE CONFIGURATION ............................................ 24
PHOTOGRAPH 4:           RADIATED EMISSION REAR VIEW, WORST CASE CONFIGURATION .............................................. 25
PHOTOGRAPH 5:           FRONT VIEW OF TRANSPONDER ............................................................................................................. 26
PHOTOGRAPH 6:           REAR VIEW OF TRANSPONDER................................................................................................................ 27
PHOTOGRAPH 7:           FRONT VIEW OF PCB................................................................................................................................... 28
PHOTOGRAPH 8:           BACK VIEW OF PCB..................................................................................................................................... 29
PHOTOGRAPH 9:           INSIDE VIEW ................................................................................................................................................. 30




                                                                                                                                                   Page 3 of 30


 Rhein Tech Laboratories                                                          AMCO Automated Systems
 360 Herndon Parkway                                                              Remote Water Meter Transponder (RWT)
 Suite 1400                                                                       FCC ID: G8JVRT02
 Herndon, VA 20170                                                                FCC Part 15.231
 http://www.rheintech.com                                                         RTL WO# 2002199




1     GENERAL INFORMATION

1.1    SCOPE

FCC Rules Part 15.231: Periodic operation in the band 40.66-40.70 MHz and above 70 MHz.

1.2    TEST FACILITY

The open area test site and conducted measurement facility used to collect the radiated data is located at 360 Herndon
Parkway, Suite 1400, Herndon, Virginia 20170. This site has been fully described in a report and approved by the
Federal Communications Commission to perform AC line conducted and radiated emissions testing (ANSI C63.4 1992).

1.3    RELATED SUBMITTAL(S)/GRANT(S)

This is an original application for Certification for AMCO Automated Systems, Model: Remote Water Meter
Transponder, FCC ID: G8JVRT02.




                                                                                               Page 4 of 30


 Rhein Tech Laboratories                                                               AMCO Automated Systems
 360 Herndon Parkway                                                                   Remote Water Meter Transponder (RWT)
 Suite 1400                                                                            FCC ID: G8JVRT02
 Herndon, VA 20170                                                                     FCC Part 15.231
 http://www.rheintech.com                                                              RTL WO# 2002199




2     TEST INFORMATION

2.1       TEST JUSTIFICATION

The EUT was tested in all three orthogonal planes in order to determine worst-case emissions. Radiated emission
measurements were made of the Fundamental and Spurious Emission levels.

2.2       EXERCISING THE EUT

The unit was tested in its typical configurations with an on-time of 15 milliseconds over a period greater than 100
milliseconds (corresponding to a duty cycle factor of –16.5 dB). The unit was also tested in a continuous transmit mode
during testing. The EUT was investigated and tested in three orthogonal axes. The worst-case configuration is listed in
this report. The carrier was also checked to verify that information was being transmitted.

2.3       CONFORMITY WITH 15.231 (e)

In order to comply with the part 15.231(e), the unit must respect the following requirements for the silent period as
shown in Plot 2-1.

      •    The device transmits only once per interrogation, and does not repeat a transmission for any interrogation.
           Devices are typically read once per month, but could be read as often as once per day.

      •    All transmissions are 15 msec. This time duration does not change, and is never greater than 15 msec.

      •    A transponder does not repeat packets at any time. It only sends one 15-msec packet reply for each
           interrogation.




                                                                                                    Page 5 of 30


Rhein Tech Laboratories                             AMCO Automated Systems
360 Herndon Parkway                                 Remote Water Meter Transponder (RWT)
Suite 1400                                          FCC ID: G8JVRT02
Herndon, VA 20170                                   FCC Part 15.231
http://www.rheintech.com                            RTL WO# 2002199



PLOT 2-1:          TIMING REQUIREMENT




TEST PERSONNEL:
        Franck Schuppius                                   11/21/2002
          Test Engineer                 Signature          Date Of Test




                                                                 Page 6 of 30


 Rhein Tech Laboratories                                               AMCO Automated Systems
 360 Herndon Parkway                                                   Remote Water Meter Transponder (RWT)
 Suite 1400                                                            FCC ID: G8JVRT02
 Herndon, VA 20170                                                     FCC Part 15.231
 http://www.rheintech.com                                              RTL WO# 2002199



2.4    TEST RESULT SUMMARY

TABLE 2-1:          TEST RESULT SUMMARY WITH FCC RULES AND REGULATIONS

        STANDARD                                                TEST
FCC 15.231 (e)               Fundamental Transmit Power
FCC 15.231 (e) & 15.205      Spurious Radiated Power
FCC 15.109                   Unintentional Radiated Emissions
FCC 15.231 (e) & 2.1049      Occupied Bandwidth
FCC 15.203                   Antenna Requirement




                                                                                    Page 7 of 30


 Rhein Tech Laboratories                                                              AMCO Automated Systems
 360 Herndon Parkway                                                                  Remote Water Meter Transponder (RWT)
 Suite 1400                                                                           FCC ID: G8JVRT02
 Herndon, VA 20170                                                                    FCC Part 15.231
 http://www.rheintech.com                                                             RTL WO# 2002199




2.5    TEST SYSTEM DETAILS

The FCC Identifiers for all equipment, plus descriptions of all cables used in the tested system are:

TABLE 2-2:          EQUIPMENT UNDER TEST (EUT)

                                                                                                                      RTL
                                                                 SERIAL                             CABLE
      PART          MANUFACTURER               MODEL                              FCC ID                              BAR
                                                                 NUMBER                          DESCRIPTION
                                                                                                                     CODE
                                               REMOTE
                                               WATER
                       AMCO
TRANSPONDER                                    METER            52870G045       G8JVRT02                N/A           14897
                  AUTOMATED SYSTEMS
                                            TRANSPONDER
                                               (RWT)




                                                                                                    Page 8 of 30


 Rhein Tech Laboratories                                 AMCO Automated Systems
 360 Herndon Parkway                                     Remote Water Meter Transponder (RWT)
 Suite 1400                                              FCC ID: G8JVRT02
 Herndon, VA 20170                                       FCC Part 15.231
 http://www.rheintech.com                                RTL WO# 2002199




2.6    CONFIGURATION OF TESTED SYSTEM




                               REMOTE WATER METER
                                  TRANSPONDER




FIGURE 1:           WORST CASE CONFIGURATION OF SYSTEM UNDER TEST




                                                                      Page 9 of 30


 Rhein Tech Laboratories                                                              AMCO Automated Systems
 360 Herndon Parkway                                                                  Remote Water Meter Transponder (RWT)
 Suite 1400                                                                           FCC ID: G8JVRT02
 Herndon, VA 20170                                                                    FCC Part 15.231
 http://www.rheintech.com                                                             RTL WO# 2002199




3     RADIATED EMISSION - §15.231

3.1    RADIATED EMISSION LIMITS TEST PROCEDURE

The EUT was placed on a non-conductive table 0.8 meters above the ground plane. The table was centered on a
motorized turntable, which allows 360-degree rotation. For measurements of the fundamental signal and spurious/
harmonics, a measurement antenna was positioned at a distance of 3 meters as measured from the closest point of the
EUT.

3.2    DUTY CYCLE

The duty cycle correction factor is calculated by 20 log (15/100), with 20 dB being the maximum allowable duty
correction factor.

The duration of each transmission was found to be not greater than one second and the silent period between
transmissions was found to be at least 30 times the duration of the transmission, but in no case less than 10 seconds.




                                                                                                  Page 10 of 30


Rhein Tech Laboratories                          AMCO Automated Systems
360 Herndon Parkway                              Remote Water Meter Transponder (RWT)
Suite 1400                                       FCC ID: G8JVRT02
Herndon, VA 20170                                FCC Part 15.231
http://www.rheintech.com                         RTL WO# 2002199




PLOT 3-1:          DUTY CYCLE PLOT




TEST PERSONNEL:
        Franck Schuppius                                11/21/2002
          Test Engineer              Signature          Date Of Test




                                                             Page 11 of 30


   Rhein Tech Laboratories                                                               AMCO Automated Systems
   360 Herndon Parkway                                                                   Remote Water Meter Transponder (RWT)
   Suite 1400                                                                            FCC ID: G8JVRT02
   Herndon, VA 20170                                                                     FCC Part 15.231
   http://www.rheintech.com                                                              RTL WO# 2002199




 3.3      RADIATED EMISSION LIMITS TEST DATA

 The fundamental was measured at 78.9 dBuV/m in peak mode at 100% duty cycle. The 16 dB duty cycle correction
 factor was subtracted from the peak result to a corrected reading of 62.9 dBuV/m compared to the average limit of 72.2
 dBuV/m per 15.35 and 15.231(e). The spurious and harmonics were corrected using the duty cycle factor and compared
 to the limit per 15.35, 15.209 and 15.231(e).

 TABLE 3-1:             RADIATED EMISSIONS

                                                                            Site
 Emission                Antenna    Turntable   Antenna     Analyzer                   Emission     Duty    Corrected
              Test                                                       Correction
Frequency                Polarity   Azimuth      Height     Reading                     Level      factor     Level       Limit
             Detector                                                     Factor
  (MHz)                   (H/V)       (deg)       (m)        (dBuV)                   (dBuV/m)      (dB)    (dBuV/m)    (dBuV/m)
                                                                          (dB/m)
415.585         Pk            V        90         1.0         90.4         -11.5        78.9        -16       62.9           72.2

 TABLE 3-2:             RADIATED EMISSIONS SPURS/HARMONICS

                                                                            Site
 Emission                Antenna    Turntable   Antenna     Analyzer                   Emission     Duty    Corrected
              Test                                                       Correction
Frequency                Polarity   Azimuth      Height     Reading                     Level      factor     Level       Limit
             Detector                                                     Factor
  (MHz)                   (H/V)       (deg)       (m)        (dBuV)                   (dBuV/m)      (dB)    (dBuV/m)    (dBuV/m)
                                                                          (dB/m)
 830.670        Pk            V        0          1.0         56.6          -5.4        51.2        -16       35.2           52.2
1243.140        Pk            V       145         1.0         45.3          -1.0        44.3        -16       28.3           54.0
1660.840        Pk            V       145         1.0         60.6           3.2        63.8        -16       47.8           54.0
2077.440        Pk            V       145         1.0         40.2          11.0        52.2        -16       36.2           54.0
 PEAK: RES. =100 KHZ, VID= 100 KHZ, AV: RES. =100 KHZ, VID= 10HZ

 TEST PERSONNEL:
            Franck Schuppius                                                                      11/24/2002
              Test Engineer                               Signature                               Date Of Test


 3.4      TEST EQUIPMENT USED FOR TESTING

 TABLE 3-3:             RADIATED SPURIOUS EMISSIONS TEST EQUIPMENT

  RTL ASSET #           MANUFACTURER            MODEL                       PART TYPE                       SERIAL NUMBER
       900772               EMCO                3161-02                Horn Antenna (2-4 GHz)                     900772
       900321               EMCO                3161-03               Horn Antenna (4-8,2 GHz)                   9508-1020
       900723                Miteq                NA                   AMP (100MHz-26 GHz                           NA
       900791           Schaffner-Chase         CBL6112               Antenna (25 MHz - 2 GHz)                     2099




                                                                                                      Page 12 of 30


 Rhein Tech Laboratories                                                       AMCO Automated Systems
 360 Herndon Parkway                                                           Remote Water Meter Transponder (RWT)
 Suite 1400                                                                    FCC ID: G8JVRT02
 Herndon, VA 20170                                                             FCC Part 15.231
 http://www.rheintech.com                                                      RTL WO# 2002199




4     MODULATED BANDWIDTH - §15.231(c)

4.1     MODULATED BANDWIDTH TEST PROCEDURE

The minimum 20 dB bandwidth per FCC 15.231(c) was performed as radiated testing with the resolution bandwidth set
at 10 kHz, and the video bandwidth set at 100 kHz. The minimum 20 dB modulated bandwidth is listed in Table 4-2.

4.2     TEST EQUIPMENT USED FOR TESTING

TABLE 4-1:          TEST EQUIPMENT USED FOR TESTING (MODULATED BANDWIDTH)

RTL ASSET #        MANUFACTURER          MODEL                      PART TYPE                    SERIAL NUMBER
      900931         Hewlett Packard      8566B        Spectrum Analyzer (100 Hz – 22 GHz)           3138A07771

4.3     MODULATED BANDWIDTH TEST DATA

TABLE 4-2:          MINIMUM 20 DB MODULATED BANDWIDTH

                    FREQUENCY (MHz)                                       20 dB BANDWIDTH (kHz)
                            415.5                                                  798.00


TEST PERSONNEL:

          Franck Schuppius                                                            12/19/2002
       Test Technician/Engineer                   Signature                           Date Of Test




                                                                                            Page 13 of 30


Rhein Tech Laboratories                          AMCO Automated Systems
360 Herndon Parkway                              Remote Water Meter Transponder (RWT)
Suite 1400                                       FCC ID: G8JVRT02
Herndon, VA 20170                                FCC Part 15.231
http://www.rheintech.com                         RTL WO# 2002199




PLOT 4-1:          MODULATED BANDWIDTH




TEST PERSONNEL:

       Franck Schuppius                                 12/19/2002
    Test Technician/Engineer         Signature          Date Of Test




                                                             Page 14 of 30


 Rhein Tech Laboratories                                             AMCO Automated Systems
 360 Herndon Parkway                                                 Remote Water Meter Transponder (RWT)
 Suite 1400                                                          FCC ID: G8JVRT02
 Herndon, VA 20170                                                   FCC Part 15.231
 http://www.rheintech.com                                            RTL WO# 2002199




5   CONCLUSION

The data in this measurement report shows that the AMCO Automated Systems, Model: Remote Water Meter
Transponder, FCC ID: G8JVRT02, complies with all the requirements of Part 15.231 of the FCC Rules.




                                                                                 Page 15 of 30


Rhein Tech Laboratories                                    AMCO Automated Systems
360 Herndon Parkway                                        Remote Water Meter Transponder (RWT)
Suite 1400                                                 FCC ID: G8JVRT02
Herndon, VA 20170                                          FCC Part 15.231
http://www.rheintech.com                                   RTL WO# 2002199




APPENDIX A: ANTENNA SPECIFICATIONS

                                              TX antenna           RX antenna




PHOTOGRAPH 1:              ANTENNA LOCATION




                                                                       Page 16 of 30


 Rhein Tech Laboratories                  AMCO Automated Systems
 360 Herndon Parkway                      Remote Water Meter Transponder (RWT)
 Suite 1400                               FCC ID: G8JVRT02
 Herndon, VA 20170                        FCC Part 15.231
 http://www.rheintech.com                 RTL WO# 2002199




APPENDIX B: AGENCY AUTHORIZATION LETTER

Please see the following page.




                                                      Page 17 of 30


 Rhein Tech Laboratories                     AMCO Automated Systems
 360 Herndon Parkway                         Remote Water Meter Transponder (RWT)
 Suite 1400                                  FCC ID: G8JVRT02
 Herndon, VA 20170                           FCC Part 15.231
 http://www.rheintech.com                    RTL WO# 2002199




APPENDIX C: CONFIDENTIALITY REQUEST LETTER

Please see the following page.




                                                         Page 18 of 30


 Rhein Tech Laboratories          AMCO Automated Systems
 360 Herndon Parkway              Remote Water Meter Transponder (RWT)
 Suite 1400                       FCC ID: G8JVRT02
 Herndon, VA 20170                FCC Part 15.231
 http://www.rheintech.com         RTL WO# 2002199




APPENDIX D: PRODUCT DESCRIPTION

Please see the following pages.




                                              Page 19 of 30


 Rhein Tech Laboratories                                   AMCO Automated Systems
 360 Herndon Parkway                                       Remote Water Meter Transponder (RWT)
 Suite 1400                                                FCC ID: G8JVRT02
 Herndon, VA 20170                                         FCC Part 15.231
 http://www.rheintech.com                                  RTL WO# 2002199




APPENDIX E: LABEL AND LABEL LOCATION




PHOTOGRAPH 2:               LOCATION OF LABEL ON DEVICE

Please refer to the following page for the label sample.




                                                                       Page 20 of 30


 Rhein Tech Laboratories         AMCO Automated Systems
 360 Herndon Parkway             Remote Water Meter Transponder (RWT)
 Suite 1400                      FCC ID: G8JVRT02
 Herndon, VA 20170               FCC Part 15.231
 http://www.rheintech.com        RTL WO# 2002199




APPENDIX F: SCHEMATICS

Please see the following page.




                                             Page 21 of 30


 Rhein Tech Laboratories         AMCO Automated Systems
 360 Herndon Parkway             Remote Water Meter Transponder (RWT)
 Suite 1400                      FCC ID: G8JVRT02
 Herndon, VA 20170               FCC Part 15.231
 http://www.rheintech.com        RTL WO# 2002199




APPENDIX G: BLOCK DIAGRAM

Please see the following page.




                                             Page 22 of 30


 Rhein Tech Laboratories          AMCO Automated Systems
 360 Herndon Parkway              Remote Water Meter Transponder (RWT)
 Suite 1400                       FCC ID: G8JVRT02
 Herndon, VA 20170                FCC Part 15.231
 http://www.rheintech.com         RTL WO# 2002199




APPENDIX H: MANUAL

Please see the following pages.




                                              Page 23 of 30


Rhein Tech Laboratories                                AMCO Automated Systems
360 Herndon Parkway                                    Remote Water Meter Transponder (RWT)
Suite 1400                                             FCC ID: G8JVRT02
Herndon, VA 20170                                      FCC Part 15.231
http://www.rheintech.com                               RTL WO# 2002199




APPENDIX I: TEST PHOTOGRAPHS




PHOTOGRAPH 3:              RADIATED EMISSION FRONT VIEW, WORST CASE
                           CONFIGURATION




                                                                   Page 24 of 30


Rhein Tech Laboratories                                AMCO Automated Systems
360 Herndon Parkway                                    Remote Water Meter Transponder (RWT)
Suite 1400                                             FCC ID: G8JVRT02
Herndon, VA 20170                                      FCC Part 15.231
http://www.rheintech.com                               RTL WO# 2002199




PHOTOGRAPH 4:              RADIATED EMISSION REAR VIEW, WORST CASE
                           CONFIGURATION




                                                                   Page 25 of 30


Rhein Tech Laboratories                                AMCO Automated Systems
360 Herndon Parkway                                    Remote Water Meter Transponder (RWT)
Suite 1400                                             FCC ID: G8JVRT02
Herndon, VA 20170                                      FCC Part 15.231
http://www.rheintech.com                               RTL WO# 2002199




APPENDIX J: EXTERNAL PHOTOGRAPHS




PHOTOGRAPH 5:              FRONT VIEW OF TRANSPONDER




                                                                   Page 26 of 30


Rhein Tech Laboratories                               AMCO Automated Systems
360 Herndon Parkway                                   Remote Water Meter Transponder (RWT)
Suite 1400                                            FCC ID: G8JVRT02
Herndon, VA 20170                                     FCC Part 15.231
http://www.rheintech.com                              RTL WO# 2002199




PHOTOGRAPH 6:              REAR VIEW OF TRANSPONDER




                                                                  Page 27 of 30


Rhein Tech Laboratories                        AMCO Automated Systems
360 Herndon Parkway                            Remote Water Meter Transponder (RWT)
Suite 1400                                     FCC ID: G8JVRT02
Herndon, VA 20170                              FCC Part 15.231
http://www.rheintech.com                       RTL WO# 2002199




APPENDIX K: INTERNAL PHOTOGRAPHS




PHOTOGRAPH 7:              FRONT VIEW OF PCB




                                                           Page 28 of 30


Rhein Tech Laboratories                       AMCO Automated Systems
360 Herndon Parkway                           Remote Water Meter Transponder (RWT)
Suite 1400                                    FCC ID: G8JVRT02
Herndon, VA 20170                             FCC Part 15.231
http://www.rheintech.com                      RTL WO# 2002199




PHOTOGRAPH 8:              BACK VIEW OF PCB




                                                          Page 29 of 30


Rhein Tech Laboratories                  AMCO Automated Systems
360 Herndon Parkway                      Remote Water Meter Transponder (RWT)
Suite 1400                               FCC ID: G8JVRT02
Herndon, VA 20170                        FCC Part 15.231
http://www.rheintech.com                 RTL WO# 2002199




PHOTOGRAPH 9:              INSIDE VIEW




                                                     Page 30 of 30



Document Created: 2003-02-04 15:59:17
Document Modified: 2003-02-04 15:59:17

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC