Test Report

FCC ID: G6DHF43H2

Test Report

Download: PDF
FCCID_1828240

                                                            BUREAU



      TEST REPORT No.: (5212)270-0837(A)


                                           TEST REPORT
                                                   0=------------,----------------------,
To:              NEW BRIGHT INDUSTRIAL CO., LTO        To:
Attn:            Lee Tak Chi                           Attn:
Address:         9/F., NEW BRIGHT BUILDING,            Address:
                 11 SHEUNG YUET ROAD, KOWLOON
                 BAY, KOWLOON, HONG KONG
Fax:             852 27953665                          Fax:
E-mail:          tclee newbri ht.com                   E-mail:
Folder No.:                                   NBT-120C208MTHS-B

Factory Name:                             NEW BRIGHT INDUSTRIAL CO., LTO
                                            9/F., NEW BRIGHT BUILDING,
Location:
                             11 SHEUNG YUET ROAD, KOWLOON BAY, KOWLOON, HONG KONG
                                             Radio Control Toy Transmitter
Product:
                                                Model No.: G6DHF43H2

                                                                                        Sample No:                                     HK120921/006



                                                                                       Test Date(s):                                  October 3,2012



                                                                                    Test Requested:                                FCC Part 15 - 2011



                                                                                       Test Method:                                ANSI C63.4 - 2009



                                                                                            FCC 10:                                      G6DHF43H2


   The results given in this report are related to the tested specimen of the described electrical apparatus.

CONCLUSION: The submitted sample was found to COMPLY with requirement of FCC Part 15 Subpart C.

                                                Authorized Signature:




BUREAU VERITAS HONG KONG LlMITED-         This report is intended for your exclusive use. An~ copying or rephcauon of this report to or for any other person or entity. or use
Kowloon Bay Office                        of our name or trademark. IS pemutted only with our pncr written perrrassion Our reJXH1 IS hrtuted to the test samples identified
1/F Pacific Trade Centre,                 herem. The results set forth in this report are not necessarily indicative or representative of the stansncal quality or charactensncs of
                                          the lot from which a test sample was taken or any similar or Identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,             includes all of the tests requested by you and the results thereof You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                         additional testing of the samples or to notify us of any errors or emissions relating to our report. provided. however. such notice
Tel: +852 2331 0888                       shall be In wntmg and shall specifically address the issue you wish to raise. A failure to raise such Issue within the prescribed time
Fax: +8522331 0889                        shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com                 contents.
                                                          Page 1 of 16


     TEST REPORT No.: (5212)270-0837(A)

     Test Result Summary

                                         EMISSION TEST
     Test requirement: FCC Part 15 - 2011
                                                                                                                         Test Result
                    Test Condition                                      Test Method
                                                                                                                      Pass       Failed
     Radiated Emission Test,                                            ANSI C63.4
     9kHz to 1GHz


     Report Revision & Sample Re-submit History:
     --




BUREAU VERITAS HONG KONG LIMITED –     This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                     of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,              herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                       the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,          includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                      additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                    shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                    shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com              contents.
                                                       Page 2 of 16


     TEST REPORT No.: (5212)270-0837(A)

     Test Laboratory & Test Instruments List

     Radiated and Conducted emissions measurements are investigated and taken pursuant to the procedures
     of ANSI C63.4 – 2009. An Open Area Test Site and Full Anechoic Chamber (FCC Listed Site,
     Registration No. 642151) are set up for investigation and located at:

                         BUREAU VERITAS HONG KONG LIMITED, EMC CENTRE
                                             No. 2106-2107, 21/F., Westin Centre,
                                                      26 Hung To Road,
                                                    Kwun Tong, Kowloon,
                                                         Hong Kong


     Test Instrument List

                                                             Radiated Emission
            EQUIPMENT               MANUFACTURER                MODEL NO.                             SERIAL NO.                             CALIBRATION DUE
            EMI TEST RECEIVER       R&S                         ESCI                                  100379                                 18-OCT-2012
            LOOP ANTENNA            ETS-LINDGREN                6502                                  00102266                               14-AUG-2013
            BILOG ANTENNA           SCHAFFNER                   CBL6112D                              25229                                  12-SEP-2013
            OPEN AREA TEST          BVCPS                       N/A                                   N/A                                    09-JUL-2013
            SITE
            ANECHOIC CHAMBER        ALBATROSS                   M-CDC                                 80374004499B                           01-DEC-2012
            COAXIAL CABLE           SUHNER                      RG214                                 N/A                                    06-OCT-2012



     Remarks: -
     N/A: Not Applicable or Not Available

     The measurement instrumentation uncertainty would be taking into consideration on each of the test result




BUREAU VERITAS HONG KONG LIMITED –                 This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                                 of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,                          herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                                   the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,                      includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                                  additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                                shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                                shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com                          contents.
                                                                   Page 3 of 16


     TEST REPORT No.: (5212)270-0837(A)

      Equipment Under Test [EUT]
      Description of Sample:
      Product:                        Radio Control Toy Transmitter
      Model No.:                      G6DHF43H2
      Additional Model information:   --
      Power Supply:                   3Vd.c. (“AA” size battery x 2)

      Description of EUT Operation:
      The Equipment Under Test (EUT) is a NEW BRIGHT INDUSTRIAL CO., LTD. of Radio
      Control toy. It is a 2 sticks and operating at 27.145MHz transmitter. The EUT continues
      to transmit while sticks are being pushed or pulled, Modulation by IC, and type is pulse
      modulation.
      The transmitter has different control:
           1. Left stick – Forward and Backward control
           2. Right stick – Leftward and Rightward control

      Antenna Requirement
      The EUT is use of a permanently antenna. The antenna consists of 36cm long wire. It is
      soldered on the PCB. The antenna is not replaceable or user serviceable. There are no
      deviations or exceptions to the specifications.

                                        Photo of Antenna




BUREAU VERITAS HONG KONG LIMITED –     This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                     of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,              herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                       the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,          includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                      additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                    shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                    shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com              contents.
                                                       Page 4 of 16


     TEST REPORT No.: (5212)270-0837(A)

      Test Results
      Radiated Emissions (Fundamental)

      Test Requirement:           FCC Part 15 Section 15.227
      Test Method:                ANSI C63.4
      Test Date(s):               2012-10-03
      Temperature:                29.0 oC
      Humidity:                   72.0 %
      Atmospheric Pressure:       100.3 kPa
      Mode of Operation:          Transmission mode
      Tested Voltage:             3Vd.c. (“AA” size battery x 2)

     Test Method:
     Radiated emissions measurements are investigated and taken pursuant to the procedures of ANSI C63.4 – 2009.

     The equipment under test (EUT) was placed on a non-conductive turntable with dimensions of 1.5m x 1m and 0.8m
     high above the ground. 3m from the EUT, a broadband antenna mounting on the mast received the signal strength.
     During the test, each emission was maximized by: having the EUT continuously working, investigated all operating
     modes, rotated about all 3 axis (X, Y & Z) and considered typical configuration to obtain worst position, manipulating
     interconnecting cables, For battery operated equipment, the equipment tests shall be perform using new battery. The
     turntable was rotated to maximize the emission level. The antenna was then moving along the mast from 1m up to
     4m until no more higher value was found. Both horizontal and vertical polarization of the antenna were placed and
     investigated.

     For below 30MHz, a loop antenna with its vertical plane is place 3m from the EUT and rotated about its vertical axis
     for maximum response at each azimuth about the EUT. And the centre of the loop shall be 1m above the ground.

     Location: The Roof, Westin Centre, 26 Hung To Road, Kwun Tong, Kowloon, Hong Kong

     Test Setup: Open Area Test Site



                                      Antenna                  Measuring
                                      Mast                     Antenna                                      Turntable




                                                                             3 meter

                           Receiver




BUREAU VERITAS HONG KONG LIMITED –              This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                              of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,                       herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                                the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,                   includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                               additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                             shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                             shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com                       contents.
                                                                Page 5 of 16


     TEST REPORT No.: (5212)270-0837(A)

     Limits for Field Strength of Fundamental Emissions [FCC 47CFR 15.227]:
           Frequency Range of                       Field Strength of                                              Field Strength of
              Fundamental                         Fundamental Emission                                           Fundamental Emission
                                                         [Peak]                                                        [Average]
                   [MHz]                                 [µV/m]                                                          [µV/m]
               26.96 – 27.28                      100,000 (100 dBµV/m)                                            10,000 (80 dBµV/m)

     Measurement Data

     Test Result of (Transmission mode): PASS

     Detection mode: Peak
      Frequency          Polarity        Antenna         Field Strength Limit at 3m                                      Margin
        (MHz)             (H/V)         Factor and           at 3m       (dBµV/m)                                         (dB)
                           and          Cable Loss         (dBµV/m)
                         degree           (dB/m)
        27.145            V/0°             11.0                   58.6                          100                        -41.4

     Detection mode: # Average
      Frequency          Polarity        Antenna         Field Strength Limit at 3m                                      Margin
        (MHz)             (H/V)         Factor and           at 3m       (dBµV/m)                                         (dB)
                           and          Cable Loss         (dBµV/m)
                         degree           (dB/m)
        27.145            V/0°             11.0                  **54.9                          80                        -25.1


      # For pulse modulated devices and using measuring equipment employing a peak
      detection mode, properly adjusted for such factor as pulse desensitisation.
      **Duty Cycle Correction = 20Log(0.655) =-3.7dB

     Note: Field Strength includes Antenna Factor and Cable Loss.

     Receiver setting:    RBW       =   100KHz
                          VBW       =   300KHz




BUREAU VERITAS HONG KONG LIMITED –                   This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                                   of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,                            herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                                     the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,                        includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                                    additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                                  shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                                  shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com                            contents.
                                                                     Page 6 of 16


     TEST REPORT No.: (5212)270-0837(A)

      Radiated Emissions (9kHz – 1GHz)
      Test Requirement:       FCC Part 15 Section 15.209
      Test Method:            ANSI C63.4
      Test Date(s):           2012-10-03
                                   o
      Temperature:            29.0 C
      Humidity:               72.0 %
      Atmospheric Pressure:   100.3 kPa
      Mode of Operation:      Transmission mode
      Tested Voltage:         3Vd.c. (“AA” size battery x 2)

     Limits for Radiated Emissions [FCC 47 CFR 15.209]:
                     Frequency Range                                                         Quasi-Peak Limits
                          [MHz]                                                                   [µV/m]
                         1.705-30                                                                   300
                           30-88                                                                    100
                          88-216                                                                    150
                         216-960                                                                    200
                        Above960                                                                    500




BUREAU VERITAS HONG KONG LIMITED –       This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                       of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,                herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                         the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,            includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                        additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                      shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                      shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com                contents.
                                                         Page 7 of 16


     TEST REPORT No.: (5212)270-0837(A)

     Measurement Data
     Test Result of (Transmission mode): PASS

     Detection mode: Quasi-Peak
                                      Antenna
                                                           Field Strength
       Frequency         Polarity    Factor and                           Limit at 3m                                           Margin
                                                               at 3m
         (MHz)            (H/V)      Cable Loss                            (dBµV/m)                                              (dB)
                                                             (dBµV/m)
                                       (dB/m)
        54.290              H            8.2                          28.8                           40.0                         -11.2
        81.435              H            7.1                          25.4                           40.0                         -14.6
        108.580             H           12.6                          23.7                           43.5                         -19.8
        135.725             H           12.2                          23.4                           43.5                         -20.1
        162.870             H            9.6                          21.7                           43.5                         -21.8
        190.015             H            9.6                          23.4                           43.5                         -20.1
        217.160             H           10.3                          25.9                           46.0                         -20.1
        244.305             H           12.3                          28.4                           46.0                         -17.6
        271.450             H           13.2                          30.3                           46.0                         -15.7
        298.595             H           13.6                          30.6                           46.0                         -15.4

                                      Antenna
                                                           Field Strength
       Frequency         Polarity    Factor and                           Limit at 3m                                           Margin
                                                               at 3m
         (MHz)            (H/V)      Cable Loss                            (dBµV/m)                                              (dB)
                                                             (dBµV/m)
                                       (dB/m)
        54.290              V            8.2                          29.6                           40.0                         -10.4
        81.435              V            7.1                          25.6                           40.0                         -14.4
        108.580             V           12.6                          23.8                           43.5                         -19.7
        135.725             V           12.2                          22.6                           43.5                         -20.9
        162.870             V            9.6                          22.0                           43.5                         -21.5
        190.015             V            9.6                          22.6                           43.5                         -20.9
        217.160             V           10.3                          23.7                           46.0                         -22.3
        244.305             V           12.3                          24.3                           46.0                         -21.7
        271.450             V           13.2                          24.3                           46.0                         -21.7
        298.595             V           13.6                          26.5                           46.0                         -19.5


     Note: Field Strength includes Antenna Factor and Cable Loss.

     Receiver setting:   RBW    =   120KHz
                         VBW    =   120KHz




BUREAU VERITAS HONG KONG LIMITED –                This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                                of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,                         herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                                  the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,                     includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                                 additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                               shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                               shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com                         contents.
                                                                  Page 8 of 16


     TEST REPORT No.: (5212)270-0837(A)

      26dB Bandwidth of Fundamental Emission

      Test Requirement:         FCC 47 CFR 15.227
      Test Method:              ANSI C63.4
      Test Date(s):             2012-10-03
      Temperature:              24.0 oC
      Humidity:                 49.0 %
      Atmospheric Pressure:     100.5 kPa
      Mode of Operation:        Transmission mode
      Tested Voltage:           3Vd.c. (“AA” size battery x 2)

      Test Method:
      The bandwidth is measured at an amplitude level reduced from the reference level by a
      specified ratio. The reference level is the level of the highest amplitude signal observed from
      the transmitter at the fundamental frequency. Once the reference level is established, the
      equipment is conditioned with typical modulating signal to produce the worst-case (i.e. the
      widest) bandwidth.




      Limits for 26dB Bandwidth of Fundamental Emission:
               Frequency                       26dB Bandwidth                                                      Limits
                 [MHz]                             [KHz]                                                           [MHz]
                27.1456                            88.96                                                   within 26.96 – 27.28




BUREAU VERITAS HONG KONG LIMITED –          This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                          of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,                   herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                            the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,               includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                           additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                         shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                         shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com                   contents.
                                                            Page 9 of 16


     TEST REPORT No.: (5212)270-0837(A)

     Measurement Data

     Test Result of 26dB Bandwidth of Fundamental Emission: PASS




BUREAU VERITAS HONG KONG LIMITED –   This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                   of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,            herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                     the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,        includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                    additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                  shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                  shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com            contents.
                                                    Page 10 of 16


     TEST REPORT No.: (5212)270-0837(A)

      Duty Cycle Correction During 100msec:

      Each function key sends a different series of characters, but each packet period
      (46.4msec) never exceeds a series of 4 long (1.6msec) and 40 short (0.6msec)
      pulses. Assuming any combination of short and long pulses maybe obtained due to
      encoding the worst case transmit duty cycle would be considered
      (4x1.6msec)+(40x0.6msec) per 46.4msec = 65.5% duty cycle. Figure A through C
      shows the characteristics of the pulse train for one of these functions.



      Remarks: -

      Duty Cycle Correction = 20Log(0.655) = -3.7dB




      The following figures [Figure A to Figure C] show the characteristics of the pulse train for one
      of these functions.




BUREAU VERITAS HONG KONG LIMITED –         This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                         of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,                  herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                           the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,              includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                          additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                        shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                        shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com                  contents.
                                                          Page 11 of 16


     TEST REPORT No.: (5212)270-0837(A)

                                     Figure A [Pulse Train]




                                     Figure B [Long Pulse]




BUREAU VERITAS HONG KONG LIMITED –   This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                   of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,            herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                     the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,        includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                    additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                  shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                  shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com            contents.
                                                    Page 12 of 16


     TEST REPORT No.: (5212)270-0837(A)

                                     Figure C [Short Pulse]




BUREAU VERITAS HONG KONG LIMITED –    This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                    of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,             herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                      the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,         includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                     additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                   shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                   shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com             contents.
                                                     Page 13 of 16


     TEST REPORT No.: (5212)270-0837(A)

      Photographs of EUT

            Front View of the product                                  Rear View of the product




              Battery compartment                                                    Battery Cover




BUREAU VERITAS HONG KONG LIMITED –   This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                   of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,            herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                     the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,        includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                    additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                  shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                  shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com            contents.
                                                    Page 14 of 16


     TEST REPORT No.: (5212)270-0837(A)


      Photographs of EUT

               Inner Circuit Top View                                          Inner Circuit Bottom View




                       Antenna




BUREAU VERITAS HONG KONG LIMITED –      This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                      of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,               herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                        the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,           includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                       additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                     shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                     shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com               contents.
                                                       Page 15 of 16


     TEST REPORT No.: (5212)270-0837(A)

                         Measurement of Radiated Emission Test Set Up




                                     ***** End of Report *****




BUREAU VERITAS HONG KONG LIMITED –   This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                   of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,            herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                     the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,        includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                    additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                  shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                  shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com            contents.
                                                    Page 16 of 16



Document Created: 2012-10-25 18:29:13
Document Modified: 2012-10-25 18:29:13

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC