RF test Report rev01

FCC ID: G6D128VA

Test Report

Download: PDF
FCCID_4126228

                         Test Report No.: FS181105N012R1



                                                               TEST REPORT
   Applicant                        New Bright Industrial Co Ltd

   Address                          New Bright Bldg 11 Sheung Yuet Road Kowloon Bay Kowloon Hong Kong


   Manufacturer or
                                    New Bright Industrial Co Ltd
   Supplier

   Address                          New Bright Bldg 11 Sheung Yuet Road Kowloon Bay Kowloon Hong Kong

   Product                          Battery Charger

   Brand Name                       N/A

   Model                            SGC1280500CU

   Additional Model &
                                    N/A
   Model Difference

   Date of tests                    Nov. 05, 2018 ~ Nov. 08, 2018

   The submitted sample of the above equipment has been tested for according to the requirements of the
   following standards:

        FCC Part 15, Subpart B, Class B


   CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                         Tested by Ryan Lu                                                             Approved by Breeze Jiang
                Project Engineer / EMC Department                                                  Senior Engineer / EMC Department




                                                                                                              Date: Dec. 20, 2018
   This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at
   http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or
   replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report
   sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the
   quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our
   report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is
   only provided upon request for accredited tests. You have 60 days from date of issuance of this report to notify us of any material error or omission caused
   by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue
   you wish to raise. A failure to raise such issue within the prescribed time shall constitute you unqualified acceptance of the completeness of this report, the
   tests conducted and the correctness of the report contents.

                                                    No. 34, Chenwulu Section, Guantai Rd., Houjie                Tel.: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                    Town, Dongguan City,                                         Fax: +86 769 8593 1080
Dongguan Branch
                                                    Guangdong 523942, China                                      Email: customerservice.dg@cn.bureauveritas.com
                                                                         Page 1 of 19                                                                Report Version 1


                    Test Report No.: FS181105N012R1


                                     TABLE OF CONTENTS
    RELEASE CONTROL RECORD ................................................................................ 3
    1        SUMMARY OF TEST RESULTS ..................................................................... 4
    1.1      MEASUREMENT UNCERTAINTY ................................................................... 4
    2        GENERAL INFORMATION .............................................................................. 5
    2.1      GENERAL DESCRIPTION OF EUT ................................................................ 5
    2.2      DESCRIPTION OF TEST MODES .................................................................. 5
    2.3      DESCRIPTION OF SUPPORT UNITS ............................................................ 5
    3     EMISSION TEST ............................................................................................. 6
    3.1   CONDUCTED EMISSION MEASUREMENT................................................... 6
    3.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ................................ 6
    3.1.2 TEST INSTRUMENTS ..................................................................................... 6
    3.1.3 TEST PROCEDURE ........................................................................................ 7
    3.1.4 DEVIATION FROM TEST STANDARD ............................................................ 7
    3.1.5 TEST SETUP................................................................................................... 8
    3.1.6 EUT OPERATING CONDITIONS .................................................................... 8
    3.1.7 TEST RESULTS .............................................................................................. 9
    3.2   RADIATED EMISSION MEASUREMENT...................................................... 11
    3.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT ................................... 11
    3.2.2 TEST INSTRUMENTS ................................................................................... 13
    3.2.3 TEST PROCEDURE ...................................................................................... 14
    3.2.4 DEVIATION FROM TEST STANDARD .......................................................... 15
    3.2.5 TEST SETUP................................................................................................. 16
    3.2.6 EUT OPERATING CONDITIONS .................................................................. 16
    3.2.7 TEST RESULTS ............................................................................................ 17
    4        APPENDIX A – MODIFICATIONS RECORDERS FOR ENGINEERING
             CHANGES TO THE EUT BY THE LAB.......................................................... 19




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel.: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                        Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 2 of 19                                                    Report Version 1


                    Test Report No.: FS181105N012R1


                                    RELEASE CONTROL RECORD

     ISSUE NO.                 REASON FOR CHANGE                                                    DATE ISSUED
     FS181105N012              Original release                                                     Nov. 28, 2018
                               Based on the original report FS181105N012 changed
     FS181105N012R1                                                                                 Dec. 20, 2018
                               the model No., but it doesn’t need to be retested.




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel.: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 3 of 19                                                    Report Version 1


                    Test Report No.: FS181105N012R1


    1 SUMMARY OF TEST RESULTS
      The EUT has been tested according to the following specifications:


                             APPLIED STANDARD: FCC Part 15, Subpart B

        Standard Section                   Test Item                  Result                     Remark

                                                                           Meets limits minimum
                                    Conducted test                    PASS passing margin is
       FCC Part 15,                                                        -14.50 dB at 0.44947 MHz
       Subpart B, Class B                                       Meets limits minimum
                                    Radiated Emission Test
                                                           PASS passing margin is
                                    (30MHz ~ 1GHz)
                                                                -15.81 dB at 170.221 MHz




    1.1 MEASUREMENT UNCERTAINTY
    Where relevant, the following measurement uncertainty levels have been estimated for
    tests performed on the EUT as specified in CISPR 16-4-2:

    This uncertainty represents an expanded uncertainty expressed at approximately the 95%
    confidence level using a coverage factor of k=2.

                  MEASUREMENT                             FREQUENCY                    UNCERTAINTY

               Conducted emission test                 0.15MHz ~ 30MHz                    +/-2.70 dB

              Radiated emissions test                    30MHz ~ 1GHz                     +/-4.04 dB




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie    Tel.: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                             Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                          Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 4 of 19                                                     Report Version 1


                    Test Report No.: FS181105N012R1


    2 GENERAL INFORMATION
    2.1 GENERAL DESCRIPTION OF EUT
       PRODUCT                               Battery Charger
       MODEL NO.                             SGC1280500CU
       ADDITIONAL MODELS                     N/A
       FCC ID                                G6D128VA
                                             For charger:
                                             Input:AC 120V, 60Hz, 10W
                                             Output: DC 12.8V,500mA
       POWER SUPPLY
                                             For battery: 500mAh
                                             Input: DC 12.8V from charger
                                             Output: DC 12.8V
       CABLE SUPPLIED                        N/A
       THE HIGHEST OPERATING
                             Below 108MHz
       FREQUENCY
    NOTE:
    1. This report is issued based on the previous report with report number FS181105N012,
       the model "SGC1280500CU" is identical with the previous test model
       "SGC0960500CU", except the model number for marketing purpose.
    2. This report FS181105N012R1 cancels and replaces the previous one with the report
       number FS181105N012 dated on Dec. 20, 2018.
    3. For a more detailed features description, please refer to the manufacturer’s
       specifications or the User's Manual.
    4. For the test results, the EUT had been tested with all conditions. But only the worst
       case was showed in test report.
    5. Please refer to the EUT photo document (Reference No.: 181105N012R1) for detailed
       product photo.



    2.2 DESCRIPTION OF TEST MODES
    The EUT was tested under the Charging (DC 12.8V 500mA) mode for all tests.


    2.3      DESCRIPTION OF SUPPORT UNITS
    The EUT has been tested as an independent unit without any other necessary
    accessories or support units.



                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel.: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                    Page 5 of 19                                                    Report Version 1


                    Test Report No.: FS181105N012R1

    3 EMISSION TEST

    3.1      CONDUCTED EMISSION MEASUREMENT
    3.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT
      TEST STANDARD: FCC Part 15, Subpart B (Section: 15.107)
                                          Class A (dBuV)                         Class B (dBuV)
          FREQUENCY (MHz)
                                       Quasi-peak   Average                  Quasi-peak Average
                 0.15 - 0.5               79          66                       66 - 56     56 - 46
                 0.50 - 5.0               73          60                         56          46
                 5.0 - 30.0               73          60                         60          50

      NOTES: (1) The lower limit shall apply at the transition frequencies.
             (2) The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50
                 MHz.
             (3) All emanations from a class A/B digital device or system, including any network of
                      conductors and apparatus connected thereto, shall not exceed the level of field strengths
                      specified above.


    3.1.2 TEST INSTRUMENTS

          Equipment                  Manufacturer          Model No.     Serial No.       Last Cal.         Next Cal.
          EMI Test Receiver          Rohde&Schwarz         ESR7          101494           Mar. 21,18        Mar. 20,19
          Artificial Mains Network   Rohde&Schwarz         ENV216        101173           Mar. 03,18        Mar. 02,19
          Artificial Mains Network   Rohde&Schwarz         ESH3-Z5       100317           Apr. 11,18        Apr. 10,19
          Voltage probe              SCHWARZBECK           TK 9421       TK 9421-176      Jan. 17,18        Jan. 16,19
                                                           ADT_Cond
          Test software              ADT                                 N/A              N/A               N/A
                                                           _V7.3.7

      NOTE:      1. The calibration interval of the above test instruments is 12 months and the
                    calibrations are traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.
                 2. The test was performed in shielding room 553.




                                     No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel.: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                     Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                     Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                     Page 6 of 19                                                    Report Version 1


                    Test Report No.: FS181105N012R1


    3.1.3 TEST PROCEDURE
    The basic test procedure was in accordance with ANSI C63.4:2014 (section 7).

    a. The EUT was placed 0.4 meters from the conducting wall of the shielded room with
       EUT being connected to the power mains through a line impedance stabilization
       network (LISN). Other support units were connected to the power mains through
       another LISN. The two LISNs provide 50 Ohm/ 50uH of coupling impedance for the
       measuring instrument.

    b. Both lines of the power mains connected to the EUT were checked for maximum
       conducted interference.

    c. The frequency range from 150 kHz to 30 MHz was searched. Emission levels under
       (Limit – 20dB) were not recorded.

     NOTE:

     1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
     2. "-": The Quasi-peak reading value also meets average limit and
        measurement with the average detector is unnecessary.
     3. Margin value = Emission level - Limit value
     4. Correction factor = Insertion loss + Cable loss
     5. Emission Level = Correction Factor + Reading Value


    3.1.4 DEVIATION FROM TEST STANDARD
    No deviation.




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel.: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                    Page 7 of 19                                                    Report Version 1


                    Test Report No.: FS181105N012R1


    3.1.5 TEST SETUP

                            V e r t ic a l G r o u n d
                            R e f e r e n c e P la n e                                              T e s t R e c e iv e r


                            EUT
          40cm




                                                             80cm

           L IS N



                                                                               H o r iz o n t a l G r o u n d
                                                                               R e f e r e n c e P la n e

        N o t e : 1 . S u p p o r t u n it s w e r e c o n n e c t e d t o s e c o n d L I S N .
                 2 .B o t h o f L I S N s ( A M N ) a r e 8 0 c m f r o m E U T a n d a t le a s t 8 0 c m
                    f r o m o t h e r u n it s a n d o t h e r m e t a l p la n e s s u p p o r t u n it s .



    3.1.6 EUT OPERATING CONDITIONS
            a. Turned on the power of all equipment.
            b. EUT was operated according to the type description in manufacturer’s
                specifications or the User's Manual.




                                         No. 34, Chenwulu Section, Guantai Rd., Houjie     Tel.: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                         Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch
                                         Guangdong 523942, China                           Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 8 of 19                                                     Report Version 1


                    Test Report No.: FS181105N012R1

    3.1.7 TEST RESULTS

                                Charging(DC
        TEST MODE                                           6DB BANDWIDTH                    9 kHz
                                12.8V/500mA)
        TEST VOLTAGE            AC 120V 60Hz                PHASE                            Line (L)
        ENVIRONMENTAL
                      25deg. C, 58% RH                      TESTED BY                        Hardy
        CONDITIONS

                                                          Emission
                Freq.        Corr.   Reading Value                                   Limit               Margin
                                                            Level
        No                  Factor     [dB (uV)]          [dB (uV)]           [dB (uV)]                    (dB)
                [MHz]        (dB)     Q.P.    AV.        Q.P.    AV.         Q.P.    AV.              Q.P.      AV.
         1     0.15000       9.94    37.64 23.17        47.58 33.11         66.00 56.00              -18.42 -22.89
         2     0.19983      10.29    28.50 14.20        38.79 24.49         63.62 53.62              -24.83 -29.13
         3     0.44947      10.27    32.11 19.60        42.38 29.87         56.88 46.88              -14.50 -17.01
         4     0.79923      10.47    22.48   7.44       32.95 17.91         56.00 46.00              -23.05 -28.09
         5     0.99825      10.40    21.01   5.09       31.41 15.49         56.00 46.00              -24.59 -30.51
         6     1.54725      10.26    10.09 -3.47        20.35   6.79        56.00 46.00              -35.65 -39.21

         REMARKS:        The emission levels of other frequencies were very low against the limit.




                                     No. 34, Chenwulu Section, Guantai Rd., Houjie     Tel.: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                     Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch
                                     Guangdong 523942, China                           Email: customerservice.dg@cn.bureauveritas.com
                                                     Page 9 of 19                                                      Report Version 1


                    Test Report No.: FS181105N012R1


                                Charging(DC
       TEST MODE                                              6DB BANDWIDTH                    9 kHz
                                12.8V/500mA)
       TEST VOLTAGE             AC 120V 60Hz                  PHASE                            Neutral (N)
       ENVIRONMENTAL
                                25deg. C, 58% RH              TESTED BY                        Hardy
       CONDITIONS

                                                            Emission
                Freq.        Corr.    Reading Value                                    Limit                Margin
                                                              Level
        No                  Factor      [dB (uV)]           [dB (uV)]           [dB (uV)]                    (dB)
                [MHz]        (dB)      Q.P.    AV.         Q.P.    AV.         Q.P.    AV.              Q.P.      AV.
         1     0.15000       9.64     39.88 24.46         49.52 34.10         66.00 56.00              -16.48 -21.90
         2     0.19950       9.76     32.23 17.20         41.99 26.96         63.63 53.63              -21.64 -26.67
         3     0.44710      10.05     29.10 20.77         39.15 30.82         56.93 46.93              -17.78 -16.11
         4     0.54934       9.73     29.24 21.69         38.97 31.42         56.00 46.00              -17.03 -14.58
         5     0.74850       9.99     25.74 17.99         35.73 27.98         56.00 46.00              -20.27 -18.02
         6     1.09725       9.72     24.93 13.53         34.65 23.25         56.00 46.00              -21.35 -22.75

       REMARKS:         The emission levels of other frequencies were very low against the limit.




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie     Tel.: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                           Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 10 of 19                                                      Report Version 1


                    Test Report No.: FS181105N012R1


    3.2      RADIATED EMISSION MEASUREMENT
    3.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT

    TEST STANDARD: FCC Part 15, Subpart B (Section: 15.109)

    Emissions radiated outside of the specified bands, shall be according to the general
    radiated limits as following:

                  Radiated Emissions Limits at 10 meters (dBµV/m)
                     FCC 15B/        FCC 15B /
      Frequencies                                     CISPR 22,                                        CISPR 22,
                     ICES-003,       ICES-003,
          (MHz)                                        Class A                                          Class B
                      Class A         Class B
          30-88          39             29.5
          88-216        43.5            33.1              40                                                 30
         216-230
                        46.4            35.6
         230-960
                                                          47                                                 37
        960-1000        49.5            43.5
       1000-3000      Avg: 49.5       Avg: 43.5      Not defined                                      Not defined
      Above 3000     Peak: 69.5      Peak: 63.5      Not defined                                      Not defined

                  Radiated Emissions Limits at 3 meters (dBµV/m)
                    FCC 15B /        FCC 15B /
      Frequencies                                    CISPR 22,                                         CISPR 22,
                    ICES-003,        ICES-003,
          (MHz)                                       Class A                                           Class B
                     Class A          Class B
          30-88        49.5              40
          88-216        54              43.5             50.5                                               40.5
         216-230
                       56.9              46
         230-960
                                                         57.5                                               47.5
        960-1000        60               54
                                                       Avg: 56                                          Avg: 50
       1000-3000
                      Avg: 60         Avg: 54         Peak: 76                                          Peak: 70
                     Peak: 80         Peak: 74         Avg: 60                                          Avg: 54
      Above 3000
                                                      Peak: 80                                          Peak: 74




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel.: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                   Page 11 of 19                                                    Report Version 1


                    Test Report No.: FS181105N012R1

      FREQUENCY RANGE OF RADIATED MEASUREMENT
      (For unintentional radiators)
       Highest frequency generated or
       Upper frequency of measurement
                                                                               Range (MHz)
       used in the device or on which the
       device operates or tunes (MHz)
                          Below 1.705                                                  30
                          1.705 – 108                                                 1000
                           108 – 500                                                  2000
                          500 – 1000                                                  5000
                                                              5th harmonic of the highest frequency
                          Above 1000
                                                                  or 40 GHz, whichever is lower

        Note: (1) The lower limit shall apply at the transition frequencies.
               (2) Emission level (dBuV/m) = 20 log Emission level (uV/m).
               (3) All emanation from a class A/B digital device or system, including any
                  network of conductors and apparatus connected thereto, shall not exceed the
                  level of field strengths specified above.




                                      No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel.: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                      Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                      Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                     Page 12 of 19                                                    Report Version 1


                    Test Report No.: FS181105N012R1


    3.2.2 TEST INSTRUMENTS
    FREQUENCY RANGE BELOW 1GHz
       Equipment         Manufacturer                   Model No.          Serial No.            Last Cal.         Next Cal.
       EMI Test Receiver Rohde&Schwarz                  ESU26              100005                Aug. 24,18        Aug. 23,19
       EMI Test Receiver Rohde&Schwarz                  ESR7               101564                Jan. 18,18        Jan. 17,19
       Trilog-Broadband
                         SCHWARZBECK                    VULB 9168          9168-555              Nov. 10, 17 Nov. 09, 18
       Antenna
       Trilog-Broadband
                         SCHWARZBECK                    VULB 9168          9168-554              Dec. 10, 17 Dec. 09, 18
       Antenna
       Preamplifier      EMCI                           EMC1135            980378                Mar. 19,18        Mar. 18,19
       Preamplifier      EMCI                           EMC1135            980423                Mar. 19,18        Mar. 18,19
       10m Semi-anechoic                                21.4m*12.1m*
                         CHANGLING                                         NSEMC006              Feb. 10,18        Feb. 09,19
       Chamber                                          8.8m
                                                        ADT_Radiated
         Test Software              ADT                                    N/A                   N/A               N/A
                                                        _V8.7.07
     NOTES: 1. The test was performed in 10m Chamber.
            2. The calibration interval of the above test instruments is 12 months. And the calibrations are
               traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.
             3. The FCC Site Registration No. is 749762.



    FREQUENCY RANGE ABOVE 1GHz
       Equipment         Manufacturer                   Model No.           Serial No.            Last Cal.   Next Cal.
       Horn Antenna      ETS-Lindgren                   3117                00085519              Dec. 10, 17 Dec. 09, 18
       Horn Antenna      SCHWARZBECK                    BBHA 9170           BBHA9170242           May 05,18 May 04,19
       Signal and
                         Rohde&Schwarz                  FSV40               101003                Apr. 21,18       Apr. 20,19
       Spectrum Analyzer
       Broadband
       Preamplifier      SCHWARZBECK                    BBV9718             266                   Apr. 18,18       Apr. 18,19
       (1~18GHz)
       Pre-Amplifier
                         EMCI                           EMC 184045          980102                Nov. 08,18       Nov. 07,19
       (18GHz-40GHz)
                                                        ADT_Radiated
         Test Software              ADT                              N/A                          N/A              N/A
                                                        _V8.7.07
     NOTES: 1. The test was performed in 10m Chamber.
            2. The calibration interval of the above test instruments is 12 months. And the calibrations are
               traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.
            3. The FCC Site Registration No. is 749762.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel.: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                          Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                          Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 13 of 19                                                    Report Version 1


                    Test Report No.: FS181105N012R1


    3.2.3 TEST PROCEDURE

    <Frequency Range below 1GHz>

    The basic test procedure was in accordance with ANSI C63.4:2014 (section 12).
    a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 10
       meter semi-anechoic chamber room. The table was rotated 360 degrees to determine
       the position of the highest radiation.
    b. The EUT was set 10 meters away from the interference-receiving antenna, which was
       mounted on the top of a variable-height antenna tower.
    c. The height of antenna is varied from 1 meter to 4 meters above the ground to
       determine the maximum value of the field strength. Both horizontal and vertical
       polarizations of the antenna are set to make the measurement.
    d. For each suspected emission, the EUT was arranged to its worst case and then the
       antenna was tuned to heights from 1 meter to 4 meters and the rotatable table was
       turned from 0 degrees to 360 degrees to find the maximum reading.
    e. The test-receiver system was set to quasi-peak detect function and specified
       bandwidth with maximum hold mode when the test frequency is below 1GHz.

      NOTE:
      1. The resolution bandwidth of test receiver/spectrum analyzer is 120kHz for Quasi-peak detection
         (QP) at frequency below 1GHz.
      2. Emission level(dBuV/m)=Raw Value(dBuV) + Correction Factor(dB/m)

      3. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) (if the raw value not
         contains the amplifier);
      4. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) – Amplifier Gain(dB) (if the
         raw value contains the amplifier).

      5. Margin value = Emission level – Limit value.




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel.: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                   Page 14 of 19                                                    Report Version 1


                    Test Report No.: FS181105N012R1

    <Frequency Range above 1GHz>

      a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at
         a 10 meters Semi-anechoic chamber room. The table was rotated 360 degrees to
         determine the position of the highest radiation.
      b. The EUT was set 3 meters away from the interference-receiving antenna, which
         was mounted on the top of a variable-height antenna tower.
      c. The height of antenna is varied from one meter to four meters above the ground
         to determine the maximum value of the field strength. Both horizontal and vertical
         polarizations of the antenna are set to make the measurement. The bore sight
         should be used during the test above 1GHz.
      d. For each suspected emission, the EUT was arranged to its worst case and then
         the antenna was tuned to heights from 1 meter to 4 meters and the rotatable table
         was turned from 0 degrees to 360 degrees to find the maximum reading.
      e. The test-receiver system was set to peak and average detect function and
         specified bandwidth with maximum hold mode when the test frequency is above 1
         GHz
      NOTE:
      1. The resolution bandwidth is 1MHz and video bandwidth of test receiver/spectrum analyzer is 3MHz for
         Peak detection at frequency above 1GHz. The resolution bandwidth of test receiver/spectrum
         analyzer is 1 MHz for Average detection (AV) at frequency above 1GHz.
      2. For measurement of frequency above 1000 MHz, the EUT was set 3 meters away from the receiver
         antenna.
      3. Emission level(dBuV/m)=Raw Value(dBuV) + Correction Factor(dB/m)
      4. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) (if the raw value not contains
         the amplifier);
      5. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) – Amplifier Gain(dB) (if the raw
         value contains the amplifier)
      6. Margin value = Emission level – Limit value.



    3.2.4 DEVIATION FROM TEST STANDARD

    No deviation.




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel.: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                   Page 15 of 19                                                    Report Version 1


                    Test Report No.: FS181105N012R1

    3.2.5 TEST SETUP

      <Frequency Range below 1GHz>
                                                                     Ant. Tower
                                                                                                 1-4m
                                                                                                 Variable
                                                     10m
              EUT&
              Support Units

                                              Turn Table

                    80cm


                                                    Ground Plane

                                                    Test Receiver




      <Frequency Range above 1GHz>

                                                            Ant. Tower                  1-4m*
                                                                                        Variable
          EUT&                                 3m                                            Bore Sight
         Support Units
                                    Turn
                                    Table
                                                Absorber

             80cm


                                            Ground Plane

                                            Spectrum analyzer

                                                                                                   Pre-amplifier



    * depends on the EUT height and the antenna 3dB beamwidth both, refer to section 7.3 of
     CISPR 16-2-3

    3.2.6 EUT OPERATING CONDITIONS
         a. Turn on the power supply of the EUT.
         b. EUT was operated according to the type description in
            manufacturer’s specifications or the User's Manual.

                                        No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel.: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                        Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 16 of 19                                                    Report Version 1


                    Test Report No.: FS181105N012R1

    3.2.7 TEST RESULTS

                                                                         FREQUENCY
        TEST MODE                    Charging(DC 12.8V/500mA)                                      30-1000MHz
                                                                         RANGE
                                                                         DETECTOR
                                                                         FUNCTION &                Quasi-Peak,
        TEST VOLTAGE                 AC 120V 60Hz
                                                                         RESOLUTION                120kHz
                                                                         BANDWIDTH
        ENVIRONMENTAL
                                     21deg. C, 61% RH                    TESTED BY: Daniel
        CONDITIONS

               ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 10M
                         Correction Raw             Emission                                   Antenna   Table
                Freq.                                                Limit        Margin
        No.               Factor     Value            Level                                     Height  Angle
               (MHz)                                               (dBuV/m)        (dB)
                          (dB/m)    (dBuV)          (dBuV/m)                                     (cm)  (Degree)
         1    52.795        -22.71       31.90         9.19          30.00         -20.81         200              48
         2    167.013       -22.28       31.91         9.63          30.00         -20.37         200             177
         3    328.518       -19.96       31.55         11.59         37.00         -25.41         200              43
         4    462.378       -17.15       32.76         15.61         37.00         -21.39         200              43
         5    546.283       -15.22       30.55         15.33         37.00         -21.67         200             344
         6    638.433       -13.24       32.36         19.12         37.00         -17.88         400             147

    REMARKS:         1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                        measured corresponding to relevant limit and recorded in the data table.
                     2. Negative sign (-) in the margin column signify levels below the limit.
                     3. Frequency range scanned: 30MHz to 1000MHz.
                     4. Only emissions significantly above equipment noise floor are reported.




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel.: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                        Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 17 of 19                                                    Report Version 1


                    Test Report No.: FS181105N012R1


                                                                        FREQUENCY
        TEST MODE                   Charging(DC 12.8V/500mA)                                    30-1000MHz
                                                                        RANGE
                                                                        DETECTOR
                                                                        FUNCTION &              Quasi-Peak,
        TEST VOLTAGE                AC 120V 60Hz
                                                                        RESOLUTION              120kHz
                                                                        BANDWIDTH
        ENVIRONMENTAL
                                    21deg. C, 61% RH                    TESTED BY: Daniel
        CONDITIONS

                  ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 10M
                           Correction       Raw         Emission                                Antenna           Table
                 Freq.                                             Limit  Margin
        No.                 Factor          Value         Level                                  Height          Angle
                (MHz)                                            (dBuV/m) (dB)
                            (dB/m)         (dBuV)       (dBuV/m)                                  (cm)          (Degree)
         1     43.387        -22.91         33.84          10.93        30.00       -19.07          300              87
         2     79.861        -26.92         40.22          13.30        30.00       -16.70          300             118
         3     99.844        -24.96         36.37          11.41        30.00       -18.59          100             357
         4     118.177       -23.33         34.24          10.91        30.00       -19.09          100             357
         5     170.221       -21.70         35.89          14.19        30.00       -15.81          100             166
         6     240.016       -21.56         33.80          12.24        37.00       -24.76          100             290

    REMARKS:         1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                        measured corresponding to relevant limit and recorded in the data table.
                     2. Negative sign (-) in the margin column signify levels below the limit.
                     3. Frequency range scanned: 30MHz to 1000MHz.
                     4. Only emissions significantly above equipment noise floor are reported.




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel.: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                        Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 18 of 19                                                    Report Version 1


                    Test Report No.: FS181105N012R1


   4 APPENDIX A – MODIFICATIONS RECORDERS FOR ENGINEERING
      CHANGES TO THE EUT BY THE LAB

    No any modifications were made to the EUT by the lab during the test.




    ---END---




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel.: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                   Page 19 of 19                                                    Report Version 1



Document Created: 2018-12-20 09:26:53
Document Modified: 2018-12-20 09:26:53

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC