FCC ID: FUSAN189

                                                                                                 Antenna
    AN189                        In—Wall On/Off Module
                                                                                                                 Wireless

The In—Wall On/Off Module allows the user to wirelessly control ceiling or wall
                                                                                                             Notily                  &
mounted lighting in the home. This product can also be used as a general input and
                                                                                                                                     o
output module to control appliances or wired alarm peripherals.                                       s1                             &




                                                                                                           °29
                                                                                                                  Local
                                                                                                      s2          input     Tem
                                                                                                                            onfefy
Main features:
®    Wireless control of wall or ceiling lights                                                       av
®    Support up to 11A resistive, 1200W incandescent or 320W (40W*8)                                                  0O
     fluorescent load.
e    Input for wall switch to preserve ordinary manual control
     Second switch input suitable for stairease lighting application
e    Dry contact output (ferminals IN, LS) can be used as actuator to turn on/off
                                                                                       Safety Precautions before Installation
     other wired devices such as sirens, doorbells, door strikes, etc.
e    Dry contact input (terminals S1, 82) can be connected to wired sensors.
                                                                                       ® Be sure to isolate or switch off mains power before installing or
It supports U—Net two—way wireless technology and is fully compatible with any            maintenance.
                                                                                       ® Avoid installing the unit in stormy or raining weather.
U—Net enabled devices. The U—Net protocol allows end devices such as AN189 to
                                                                                       ®— Do ensure that the power supply circuit is protected by a 16 amp circuit
pair with a U—Net gateway as central control making it suitable for smart home cloud
based platforms such as HomeSys.                                                          breaker or suitable equivalent fuse.

Product Overview                                                                       IMPORTANT
                                                                                       Installation must be performed by skilled technicians who are informed about the
                     Switch Contact                                                    standards and technical requirements of the appliance and its proper installation.
                                                                                       Note that the In—Wall On/Off Module is designed to be installed in a wall switch
                            C5@
                            is 1e is             LeD
                                                                                       box to operate.
                                       C                                               Check your local codes as they apply to your situation. If the house wiring is of
                                                                                       aluminum, consult with an electrician about proper wiring methods.
                                       S    Link key/                                  Before proceeding with the installation, TURN OFF THE POWER TO THE
                                       S    Control button                             LIGHTING CIRCUIT AT THE CIRCUIT BREAKER OR FUSE BOX TO AVOID
                               1sS                                                     ELECTRICAL SHOCK.
                         No wug >
                        ©00
                              Wiring Terminals



The diagram below shows the major internal blocks of the module.


Wiring installation
                                                                                         For actuator applications
For lighting applications                                                                The module‘s dry contact output makes it easy to connect any device with all kinds
                                                                                         of voltages. Below is an example connection for a typical DC load such as motors or
1. Switch off or isolate the AC mains power before installing.
                                                                                         LED light strip.
2. Remove the wall switch connected to the light. You should see an electrical wall
   box where the cables of AC mains come in.
                                                                                         1. Switch off or isolate the AC mains power before installing.
3. Wire up the module to the AC mains and the load (light) according to the wiring
                                                                                         2. Connect the AC mains and the load to the module according to the diagram
   diagram below. Terminal S1 connects to the wall switch to turn on/off the output.



                                                                                                       ‘=—
                                                                                            below. Here, input terminal S$1 is optional.
            L                                                                                          L
            N



                            q                                                                                                     o        DOvotage
                                                                                                                                                              &n
                                                                                                                                                              %’\ be
                                                                                                                                                                / Load
                      L                 S1

                 ®        @0        6        @         6       ©                                              u__n          lav       s1      in                \is
                                                                                                             2   a                           h                 &A
                                                                                                            ® ®         o         6        ®                   ®
                 © Button   O LeD                      Reley
                                                                                                             O Button   O LED                         Relay

     Note: Input S2 is optional and will reverse the on/off status of S1

   When connecting the "L" terminal, it is recommended to use an external terminal              WARNING
   block to first split the L cable from AC mains into two wires before inserting into          Due to connection to AC mains, the in—wall
   the module as shown below. Try to use 1.25m m* wires for all AC connections.                 module should be placed inside an enclosed
                                                                                                casing to avoid accidents from electrical contact.
                                                                                                Ideally an electrical wall box should be used
                                                                                                whenever possible.
                                                                                                (Example of electrical box on right)


                                             Terminal block to
                                             split L terminal                            3. Switch the AC mains power back on to power up the unit.




            L cable




4. When wiring is completed, do not assemble the module into the wall box just yet.
5. Switch the AC mains power back on to power up the unit.


Binding with HomeSys
                                                                                                                                       ADD A NEW DEVICE               *
1. Check the LED on the unit is not steady on. If it is, press the Link key once to                          Add a In Wall Switch
    turn it off.
2. Log into the HomeSys account from a web browser.
   Select "System".
&




4. Select "Add a New Device", then "In Wall Switch".                                                                                Your new device was added

                    ADD A NEW DEVICE                                      *
                                                                                                        Note: If the LED blinks steadily for 30 seconds followed by 3 rapid flashes, this
                                                                                                        means the binding was unsuccessful. Abort and repeat steps 4 to 6 above.


                                                   Keyiob    Voice Sren                           8. Once binding is complete, switch off the AC mains power again.
                                                                                                  9. With the AC mains turned off, assemble and secure the in—wall module inside the
                   S               —               AoMn      &‘
                                                                                                      electrical box (or other housing) to avoid any physical contact with user.
                                                                                                  10.Switch the AC mains on again when complete. The in—wall module is ready to
                   Detector Flood Detector    SmatPlug.     InWal Swich
                                                                                                      use.
                                                                &
                                An |a|         (                    )
5. Click ‘Next again until the screen below appears. This means the gateway is                    Operation
    entering binding mode.
                                                                                                  The output of the module can be operated either;
                                         ADD A NEW DEVICE                                     *   —    Remotely through the gateway,
              Add a In Wall Switch
                                                                                                  —   Manually through the Control button, or
                                                                                                  —   Manually using an external wall switch on terminals $1/$S2.
                                                                                                  The LED indicator on the unit will always indicate the status of the output, i.e. LED
                                                                                                  turns on when the output is on.

                                                                                                  By default terminals $1/82 supports Single—Pole—Double—Throw (SPDT) type of
                                                                                                  binary switch common in most homes. This can be configured to support
                       Press and hold the On/Off button for 3 seconds until the LED flashes       Tact/Push—button type switches, either through remote settings on the Gateway or
                                                   moderately.
                                                                                                  locally using the Control button.

                                                                                                  To configure it locally to Tact/Push—button, press the Control button 3 times within
                                                                                                  1.5 seconds. The led will flash 3 times indicating change is complete. Repeating this
6. Press and hold the Link key for 3 seconds until its LED flashes, then release.                 step will toggle it back to binary switch.
7. The screen below will appear in 10 seconds if the process is successful.


Troubleshooting                                                                                 Specifications

Symptom                        Cause of Failure              Recommendation                       Frequency Range             868.3 MHz / 923.0 MHz
                                                                                                  Power Input                 220—240V/50Hz , 100—120V/60Hz
Device not responding and      |The device is not wired to   |Check if wiring is correct, or
                                                                                                                              Resistive load Max.11A,
LED not displaying             the maings power correctly    |voltage is too high or too low
                                                                                                 Maximum Power Load           Incandescent load Max. 1200W,
LED displaying, but cannot                                                                                                    Fluorescent load Max.320W
                               The connected load has its |Turn the switch of the connected
control On/Off status of                                                                         Working Temperature  —10°C — 40°C
                               own on/off switch          load to On.
connected load                                                                                  Specifications are subject to change without notice




                                                                                                                                                                       ce £ re
Can press button to control,                                 Repeat the steps in Binding with
                               Binding was not successful HomeSys
but cannot control by RF



Reset to Factory Settings
To reset the unit back to factory default state:                                                Federal Communication Commission Interference Statement
                                                                                                This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
1. Make sure the LED on the unit is turned off. If it is on, press the Link key once to         to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
                                                                                                interference in a residential installation. This equipment generates, uses and can radiate radio frequency
   turn it off.                                                                                 energy and, if not installed and used in accordance with the instructions, may cause harmful interference
                                                                                                to radio communications. However, there is no guarantee that interference will not occur in a particular
2. Press and hold the Link key on the module for 3 seconds until the LED turns on               installation. If this equipment does cause harmful interference to radio or television reception, which can
   and then release. The LED will start to flash.                                               be determined by turning the equipment off and on, the user is encouraged to try to correct the
                                                                                                interference by one of the following measures:
3. Press and hold the Link key again for more than 6 seconds until the LED turns                —      Reorient or relocate the receiving antenna.
                                                                                                       Increase the separation between the equipment and receiver.
   off, then release. The LED will flash every 2 seconds indicating the unit is now                    Connect the equipment into an outlet on a circuit different from that to which the receiver is
                                                                                                       connected.
   reset back to factory default settings.                                                             Consult the dealer or an experienced radio/TV technician for help.
                                                                                                This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
                                                                                                (1) This device may not cause harmful interference, and (2) this device must accept any interference
Auto Binding                                                                                    received, including interference that may cause undesired operation.
Once reset back to factory settings and first powered up again, the unit will attempt           FCC Caution: Any changes or modifications not expressly approved by the party responsible for
                                                                                                compliance could void the user‘s authority to operate this equipment.
to automatically bind with any U—Net compatible gateway for 30 seconds. This is                 This transmitter must not be co—located or operating in conjunction with any other antenna or transmitter.
called Auto—binding.

If binding is unsuccessful after 30 seconds, Auto—binding process will stop and the             WARNING:
LED indicator will flash slowly every 2 seconds, implying this unit has never paired            Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.
                                                                                                Contact your local government for information regarding the collection systems available.
with any device.                                                                                If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the
Note: During Auto—binding, pressing the Control button will not turn on/off the                 groundwater and get into the food chain, damaging your health and well—being.
                                                                                                When replacing old appliances with new ones, the retailer is legally obligated to take back your old
connected load.                                                                                 appliance for disposal at least for free of charge.

Auto—binding can be restarted again by disconnecting and reconnecting power to
the unit.
                                                                                                      &