Test Report

FCC ID: FSUGMZKI

Test Report

Download: PDF
FCCID_1861214

             Compliance Certification Services Inc.
             FCC ID: FSUGMZKI                                               Report No.: T121029D04-RP1



                         FCC 47 CFR PART 15 SUBPART C


                                       TEST REPORT


                                               For


                                     PenSketch T609A


                                     Model: GT-120002


                                   Trade Name: Genius

                                             Issued to

                                 KYE SYSTEMS CORP.
                           No.492, Chongxin Rd., Sanchong Dist.,
                          New Taipei City, 24160, Taiwan, (R.O.C.)

                                             Issued by

                       Compliance Certification Services Inc.
                           No.11, Wugong 6th Rd., Wugu Dist.,
                          New Taipei City 24891, Taiwan. (R.O.C.)
                                   http://www.ccsrf.com
                                    service@ccsrf.com
                              Issued Date: December 10, 2012




Note: This report shall not be reproduced except in full, without the written approval of Compliance
 Certification Services Inc. This document may be altered or revised by Compliance Certification
      Services Inc. personnel only, and shall be noted in the revision section of the document.



                                             Page 1 / 23                                         Rev.00


          Compliance Certification Services Inc.
          FCC ID: FSUGMZKI                               Report No.: T121029D04-RP1



                                      Revision History


            Issue                                         Effect
Rev.        Date                             Revisions    Page       Revised By
 00    December 10, 2012     Initial Issue                 ALL        Eunice Shen




                                             Page 2                          Rev.00


                      Compliance Certification Services Inc.
                      FCC ID: FSUGMZKI                                                                          Report No.: T121029D04-RP1




                                               TABLE OF CONTENTS
1    TEST RESULT CERTIFICATION............................................................................................. 4

2    EUT DESCRIPTION .................................................................................................................... 5

3    TEST METHODOLOGY ............................................................................................................. 6
    3.1.     EUT CONFIGURATION....................................................................................................... 6
    3.2.     EUT EXERCISE .................................................................................................................... 6
    3.3.     GENERAL TEST PROCEDURES........................................................................................ 6
    3.4.     FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS.......................................... 7
    3.5.     DESCRIPTION OF TEST MODES ...................................................................................... 7

4    INSTRUMENT CALIBRATION................................................................................................. 8
    4.1.     MEASURING INSTRUMENT CALIBRATION.................................................................. 8
    4.2.     MEASUREMENT EQUIPMENT USED .............................................................................. 8
    4.3.     MEASUREMENT UNCERTAINTY .................................................................................... 9

5    FACILITIES AND ACCREDITATIONS ................................................................................. 10
    5.1.     FACILITIES......................................................................................................................... 10
    5.2.     EQUIPMENT....................................................................................................................... 10
    5.3.     TABLE OF ACCREDITATIONS AND LISTINGS ........................................................... 11

6    SETUP OF EQUIPMENT UNDER TEST ................................................................................ 12
    6.1.     SETUP CONFIGURATION OF EUT ................................................................................. 12
    6.2.     SUPPORT EQUIPMENT .................................................................................................... 12

7    FCC PART 15.209 REQUIREMENTS...................................................................................... 13
    7.1.     RADIATED EMISSIONS ................................................................................................... 13
    7.2.     POWERLINE CONDUCTED EMISSIONS ....................................................................... 18

APPENDIX I PHOTOGRAPHS OF TEST SETUP ....................................................................... 21




                                                                       Page 3                                                                   Rev.00


                Compliance Certification Services Inc.
                FCC ID: FSUGMZKI                                             Report No.: T121029D04-RP1




1 TEST RESULT CERTIFICATION

Applicant:                      KYE SYSTEMS CORP.
                                No.492, Chongxin Rd., Sanchong Dist.,
                                New Taipei City, 24160, Taiwan, (R.O.C.)
Equipment Under Test:           PenSketch T609A
Trade Name:                     Genius
Model:                          GT-120002
Date of Test:                   December 3 ~ 7, 2012
                                 APPLICABLE STANDARDS
                   STANDARD                                          TEST RESULT
         FCC 47 CFR Part 15 Subpart C                           No non-compliance noted


We hereby certify that:
The above equipment was tested by Compliance Certification Services Inc. The test data, data
evaluation, test procedures, and equipment configurations shown in this report were made in
accordance with the procedures given in ANSI C63.4: 2009 and the energy emitted by the
sample tested as described in this report is in compliance with the requirements of FCC Rules
Part 15.207, 15.209.
The test results of this report relate only to the tested sample identified in this report.



Approved by:                                              Reviewed by:




Miller Lee                                                Gina Lo
Section Manager                                           Section Manager
Compliance Certification Services Inc.                    Compliance Certification Services Inc.




                                                 Page 4                                            Rev.00


              Compliance Certification Services Inc.
              FCC ID: FSUGMZKI                                       Report No.: T121029D04-RP1




2 EUT DESCRIPTION

 Product                             PenSketch T609A


 Trade Name                          Genius


 Model Number                        GT-120002


 Model Discrepancy                   N/A


 Received Date                       October 29, 2012


 Power Supply                        Powered from host device via USB Cable.


 Frequency Range                     960kHz +/- 10kHz


 Antenna Specification               Loop Antenna

Remark:
   1.     The sample selected for test was engineering sample that approximated to production
          product and was provided by manufacturer.
   2.     This submittal(s) (test report) is intended for FCC ID: FSUGMZKI filing to comply
          with Section 15.209 of the FCC Part 15, Subpart C Rules.




                                              Page 5                                     Rev.00


              Compliance Certification Services Inc.
              FCC ID: FSUGMZKI                                         Report No.: T121029D04-RP1



3 TEST METHODOLOGY
The tests documented in this report were performed in accordance with ANSI C63.4 (2003) and
FCC CFR 47 Part 2, 15.207, 15.209.
3.1. EUT CONFIGURATION
The EUT configuration for testing is installed on RF field strength measurement to meet the
Commissions requirement and operating in a manner that intends to maximize its emission
characteristics in a continuous normal application.
3.2. EUT EXERCISE
The EUT was operated in the engineering mode to fix the TX frequency that was for the purpose
of the measurements.
3.3. GENERAL TEST PROCEDURES
Conducted Emissions
The EUT is placed on the turntable, which is 0.8 m above ground plane. According to the
requirements in Section 13.1.4.1 of ANSI C63.4 (2003). Conducted emissions from the EUT
measured in the frequency range between 0.15 MHz and 30MHz using CISPR Quasi-peak and
average detector modes.

Radiated Emissions
The EUT is placed on a turn table, which is 0.8 m above ground plane. The turntable shall rotate
360 degrees to determine the position of maximum emission level. EUT is set 3m away from the
receiving antenna, which varied from 1m to 4m to find out the highest emission. And also, each
emission was to be maximized by changing the polarization of receiving antenna both horizontal
and vertical. In order to find out the maximum emissions, exploratory radiated emission
measurements were made according to the requirements in Section 13.1.4.1 of ANSI C63.4
(2003).




                                             Page 6                                           Rev.00


                Compliance Certification Services Inc.
                FCC ID: FSUGMZKI                                           Report No.: T121029D04-RP1




3.4. FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS
(a) Except as shown in paragraph (d) of this section, only spurious emissions are permitted in
    any of the frequency bands listed below:

               MHz                     MHz                   MHz                    GHz
           0.090 - 0.110          16.42 - 16.423           399.9 - 410           4.5 - 5.15
           1
           0.495 - 0.505       16.69475 - 16.69525          608 - 614            5.35 - 5.46
         2.1735 - 2.1905       16.80425 - 16.80475         960 - 1240            7.25 - 7.75
          4.125 - 4.128            25.5 - 25.67            1300 - 1427           8.025 - 8.5
        4.17725 - 4.17775          37.5 - 38.25           1435 - 1626.5           9.0 - 9.2
        4.20725 - 4.20775            73 - 74.6           1645.5 - 1646.5          9.3 - 9.5
          6.215 - 6.218             74.8 - 75.2            1660 - 1710           10.6 - 12.7
        6.26775 - 6.26825          108 - 121.94          1718.8 - 1722.2        13.25 - 13.4
        6.31175 - 6.31225           123 - 138              2200 - 2300          14.47 - 14.5
          8.291 - 8.294           149.9 - 150.05           2310 - 2390          15.35 - 16.2
          8.362 - 8.366            156.52475 -            2483.5 - 2500          17.7 - 21.4
        8.37625 - 8.38675           156.52525              2655 - 2900          22.01 - 23.12
        8.41425 - 8.41475         156.7 - 156.9            3260 - 3267           23.6 - 24.0
          12.29 - 12.293        162.0125 - 167.17          3332 - 3339           31.2 - 31.8
       12.51975 - 12.52025        167.72 - 173.2          3345.8 - 3358         36.43 - 36.5
       12.57675 - 12.57725          240 - 285              3600 - 4400                (2)
          13.36 - 13.41            322 - 335.4
   1
       Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz.
   2
       Above 38.6

(b) Except as provided in paragraphs (d) and (e), the field strength of emissions appearing within
    these frequency bands shall not exceed the limits shown in Section 15.209. At frequencies
    equal to or less than 1000 MHz, compliance with the limits in Section 15.209 shall be
    demonstrated using measurement instrumentation employing a CISPR quasi-peak detector.
    Above 1000 MHz, compliance with the emission limits in Section 15.209 shall be
    demonstrated based on the average value of the measured emissions. The provisions in
    Section 15.35 apply to these measurements.
3.5. DESCRIPTION OF TEST MODES
The EUT (model: GT-120002) had been tested under operating condition.
Test program used to control the EUT for staying in continuous transmitting mode was
programmed.
After verification, all tests were carried out with the worst case test modes as shown below
1GHz.
Channel 960kHz were chosen for full testing.




                                               Page 7                                           Rev.00


               Compliance Certification Services Inc.
               FCC ID: FSUGMZKI                                           Report No.: T121029D04-RP1




4 INSTRUMENT CALIBRATION
4.1. MEASURING INSTRUMENT CALIBRATION
The measuring equipment, which was utilized in performing the tests documented herein, has
been calibrated in accordance with the manufacturer's recommendations for utilizing calibration
equipment, which is traceable to recognized national standards.
4.2. MEASUREMENT EQUIPMENT USED
Equipment Used for Emissions Measurement
Remark: Each piece of equipment is scheduled for calibration once a year and Loop Antenna is
scheduled for calibration once three years.
                                       3M Chamber Test Site
  Name of Equipment      Manufacturer          Model          Serial Number      Calibration Due
   Spectrum Analyzer         Agilent           E4446A          US42510268           11/06/2013
    EMI Test Receiver         R&S                ESCI            100064             03/01/2013
      Pre-Amplifier       Mini-Circults      ZFL-1000LN        SF350700823          01/13/2013
                                           AFS44-00102650-
      Pre-Amplifier          MITEQ                               1415367            11/19/2013
                                              42-10P-44
     Bilog Antenna        Sunol Sciences         JB3             A030105            10/02/2013
      Horn Antenna           EMCO                3117           00055165            02/14/2013
       Turn Table             CCS              CC-T-1F            N/A                 N.C.R
     Antenna Tower            CCS              CC-A-1F            N/A                 N.C.R
       Controller             CCS              CC-C-1F            N/A                 N.C.R
        Site NSA              CCS                N/A              N/A               12/23/2012
        Test S/W                                   EZ-EMC (CCS-3A1RE)


                                Conducted Emission room # B
  Name of Equipment      Manufacturer        Model          Serial Number         Calibration Due
   EMI Test Receiver         R&S             ESCI               101203              09/13/2013
        LISN                 R&S            ESH3-Z5          848773/014             12/06/2013
        LISN            SCHWARZBECK        NSLK 8127           8127-541             12/14/2012
    Coaxial Cable          Commate        CFD300-NL               NA                12/06/2013
      Test S/W                                      CCS-3A1-CE




                                               Page 8                                            Rev.00


                 Compliance Certification Services Inc.
                 FCC ID: FSUGMZKI                                                 Report No.: T121029D04-RP1




4.3. MEASUREMENT UNCERTAINTY
                   PARAMETER                                  UNCERTAINTY
Powerline Conducted Emission                                       +/- 1.2575
3M Semi Anechoic Chamber / 30M~200M                                +/- 4.0138
3M Semi Anechoic Chamber / 200M~1000M                              +/- 3.9483
3M Semi Anechoic Chamber / 1G~8G                                   +/- 2.5975
3M Semi Anechoic Chamber / 8G~18G                                  +/- 2.6112
3M Semi Anechoic Chamber / 18G~26G                                 +/- 2.7389
3M Semi Anechoic Chamber / 26G~40G                                 +/- 2.9683

Remark: This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level
         using a coverage factor of k=2.




                                                     Page 9                                               Rev.00


               Compliance Certification Services Inc.
               FCC ID: FSUGMZKI                                         Report No.: T121029D04-RP1




5 FACILITIES AND ACCREDITATIONS
5.1. FACILITIES
All measurement facilities used to collect the measurement data are located at

   No.199, Chunghsen Road, Hsintien City, Taipei Hsien, Taiwan, R.O.C.
   Tel: 886-2-2217-0894 / Fax: 886-2-2217-1029

   No.11, Wugong 6th Rd., Wugu Dist., New Taipei City 24891, Taiwan. (R.O.C.)
   Tel: 886-2-2299-9720 / Fax: 886-2-2298-4045

   No.81-1, Lane 210, Bade 2nd Rd., Lujhu Township, Taoyuan County 33841, TAIWAN, R.O.C.
   Tel: 886-3-324-0332 / Fax: 886-3-324-5235
The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.4
(2003) and CISPR Publication 22.
5.2. EQUIPMENT
Radiated emissions are measured with one or more of the following types of linearly polarized
antennas: tuned dipole, biconical, log periodic, bi-log, and/or ridged waveguide, horn. Spectrum
analyzers with pre-selectors and quasi-peak detectors are used to perform radiated
measurements.
Conducted emissions are measured with Line Impedance Stabilization Networks and EMI Test
Receivers.
Calibrated wideband preamplifiers, coaxial cables, and coaxial attenuators are also used for
making measurements.
All receiving equipment conforms to CISPR Publication 16-1, “Radio Interference Measuring
Apparatus and Measurement Methods.”




                                              Page 10                                          Rev.00


                 Compliance Certification Services Inc.
                 FCC ID: FSUGMZKI                                                    Report No.: T121029D04-RP1




5.3. TABLE OF ACCREDITATIONS AND LISTINGS
 Country Agency Scope of Accreditation                                                    Logo

                        3M Semi Anechoic Chamber (FCC MRA: TW1039) to perform
 USA         FCC
                        FCC Part 15 measurements
                                                                                          FCC MRA: TW1039
                        LP0002, RTTE01, FCC Method-47 CFR Part 15 Subpart C, D, E,
                        RSS-210, RSS-310
                        IDA TS SRD, AS/NZS 4268, AS/NZS 4771, TS 12.1 & 12,2,
                        ETSI EN 300 440-1, ETSI EN 300 440-2, ETSI EN 300 328,
                        ETSI EN 300 220-1, ETSI EN 300 220-2, ETSI EN 301 893,
                        ETSI EN 301 489-1/3/7/17
 Taiwan      TAF
                        FCC OET Bulletin 65 + Supplement C,
                        EN 50360, EN 50361, EN 50371, RSS 102, EN 50383, EN 50385,
                        EN 50392, IEC 62209, CNS 14958-1, CNS 14959
                        FCC Method –47 CFR Part 15 Subpart B
                        IEC / EN 61000-3-2, IEC / EN 61000-3-3,
                        IEC / EN 61000-4-2/3/4/5/6/8/11

             Industry
 Canada                 3M Semi Anechoic Chamber (IC 2324G-1 / IC 2324G-2) to perform     IC 2324G-1
             Canada
                                                                                          IC 2324G-2

Note: No part of this report may be used to claim or imply product endorsement by A2LA, TAF or other government
agency.




                                                     Page 11                                             Rev.00


                    Compliance Certification Services Inc.
                    FCC ID: FSUGMZKI                                               Report No.: T121029D04-RP1




6 SETUP OF EQUIPMENT UNDER TEST
6.1. SETUP CONFIGURATION OF EUT
See test photographs attached in Appendix 1 for the actual connections between EUT and
support equipment.
6.2. SUPPORT EQUIPMENT
 No. Device Type          Brand         Model        Series No.       FCC ID         Data Cable       Power Cord
                                                                                                    AC I/P:
                                                                                                    Unshielded, 1.8m
  1    Notebook PC          HP        dv6-1332TX    CNF9491GM9      PD9112BNHU            N/A       DC O/P:
                                                                                                    Unshielded, 1.8m
                                                                                                    with a core
                                                                                                    AC I/P:
                                                                                                    Unshielded, 1.8m
  2    Notebook PC        DELL          PP19L         GK102 A00     QDS-BRCM1021          N/A       DC O/P:
                                                                                                    Unshielded, 1.8m
                                                                                                    with a core
                                                   CN-0XK290-7161       FCC
  3    LCD Monitor        DELL         3008WFP                                     Unshielded, 1.8m Shielded, 1.8m
                                                     8-846-169L         DoC
                                                                        FCC
  4       Printer         EPSON       STYLUS C60     DR3K041995                    Shielded, 1.8m   Unshielded, 1.8m
                                                                        DoC
                                                                        FCC
  5    1TB 3.5" HDD       Buffalo   HD-HX1.0TU3-AP 15564891207204                  Shielded, 1m            N/A
                                                                        DoC
                                                                        FCC
  6     USB Mouse         DELL         M056U0A        F0R00D2V                     Shielded, 1.8m          N/A
                                                                        DoC
Remark: Grounding was established in accordance with the manufacturer’s requirements and conditions
        for the intended use.




                                                    Page 12                                                   Rev.00


               Compliance Certification Services Inc.
               FCC ID: FSUGMZKI                                             Report No.: T121029D04-RP1



7 FCC PART 15.209 REQUIREMENTS
7.1. RADIATED EMISSIONS
LIMIT
1. According to §15.209(a), except as provided elsewhere in this Subpart, the emissions from an
   intentional radiator shall not exceed the field strength levels specified in the following table:

                                              Field Strength              Measurement Distance
           Frequency (MHz)
                                                  (μV/m)                          (m)
              0.009–0.490                      2400/F(kHz)                           300
              0.490–1.705                     24000/F(kHz)                           30
               1.705–30.0                           30                               30
                  30–88                           100**                               3
                 88–216                           150**                               3
                216–960                           200**                               3
               Above 960                            500                               3
   Remark: Except as provided in paragraph (g), fundamental emissions from intentional
   radiators operating under this Section shall not be located in the frequency bands 54-72
   MHz, 76-88 MHz, 174-216 MHz or 470-806 MHz. However, operation within these
   frequency bands is permitted under other sections of this Part, e.g., Sections 15.231 and
   15.241.
2. In the emission table above, the tighter limit applies at the band edges.
                                             Field Strength                   Field Strength
            Frequency (Hz)
                                           (μV/m at 3-meter)               (dBμV/m at 3-meter)
                  30-88                           100                               40
                 88-216                             150                             43.5
                216-960                             200                              46
               Above 960                            500                              54




                                                Page 13                                          Rev.00


              Compliance Certification Services Inc.
              FCC ID: FSUGMZKI                            Report No.: T121029D04-RP1



TEST CONFIGURATION
9kHz ~ 30MHz




                            3m
                                                         Loop antenna
      EUT

                                                       Spectrum /
                                                        Receiver


            Turntable                  1m
                           0.8m




  Reference ground plane



30MHz ~ 1 GHz

                                                       Antenna
                                                        tower


                            3m
                                                         Bilog antenna
      EUT
                                  4m
                                                       Spectrum /
                                                        Receiver


            Turntable                  1m
                           0.8m
                                                       Pre-amp




  Reference ground plane




                                            Page 14                           Rev.00


               Compliance Certification Services Inc.
               FCC ID: FSUGMZKI                                       Report No.: T121029D04-RP1




TEST PROCEDURE
For 9kHz ~ 30MHz
1.   The EUT is placed on a turntable, which is 0.8m above ground plane.
2.   The turntable shall be rotated for 360 degrees to determine the position of maximum
     emission level.
3.   EUT is set 3m away from the receiving antenna, The center of the loop shall be 1 m above
     the ground then to find out the highest emissions.
4.   Maximum procedure was performed on the six highest emissions to ensure EUT
     compliance.
5.   And also, each emission was to be maximized by rotated of receiving antenna axis
6.   Set the spectrum analyzer in the following setting as:
     RBW=10kHz / VBW=30kHz / Sweep=AUTO
7.   Repeat above procedures until the measurements for all frequencies are complete.

For 30MHz ~ 1GHz
1.   The EUT is placed on a turntable, which is 0.8m above ground plane.
2.   The turntable shall be rotated for 360 degrees to determine the position of maximum
     emission level.
3.   EUT is set 3m away from the receiving antenna, which is varied from 1m to find out
     the highest emissions.
4.   Maximum procedure was performed on the six highest emissions to ensure EUT
      compliance.
5.   And also, each emission was to be maximized by changing the polarization of receiving
     antenna both horizontal and vertical.
6.   Set the spectrum analyzer in the following setting as:
     RBW=100kHz / VBW=300kHz / Sweep=AUTO
7.   Repeat above procedures until the measurements for all frequencies are complete.

TEST RESULTS
No non-compliance noted.




                                              Page 15                                      Rev.00


                 Compliance Certification Services Inc.
                 FCC ID: FSUGMZKI                                          Report No.: T121029D04-RP1




TEST DATA
For 9kHz ~ 30MHz
Operation Mode:              TX mode                Test Date:              December 3, 2012
Temperature:                 26°C                   Tested by:              Shawn Wu
Humidity:                    50 % RH                Polarity:               Ver. / Hor.


                                    Correction
 Frequency         Reading                         Result       Limit 3m     Margin       Detector Mode
                                     Factor
   (MHz)           (dBuV)                        (dBuV/m)       (dBuV/m)      (dB)        (PK/QP/AVG)
                                     (dB/m)
   0.960            46.27             19.28       65.55          67.96         -2.41          Peak
   0.0090           122.41             0.00       122.41         128.51        -6.10          Peak
   0.1701           45.52             32.90       78.42          116.88       -38.46          Peak
   0.1903           43.18             32.21       75.39          115.43       -40.04          Peak
   0.2235           52.28             31.09       83.37          113.03       -29.66          Peak
   0.2548           52.32             30.10       82.42          110.77       -28.35          Peak
   0.4708           51.59             26.18       77.77          95.19        -17.42          Peak
   0.4900           38.35             25.83       64.18          73.80         -9.62          Peak
   1.4048           37.74             16.65       54.39          65.64        -11.25          Peak
   6.5986           26.98              6.98       33.96          69.50        -35.54          Peak
  14.1235           21.65              5.66       27.31          69.50        -42.19          Peak
  24.6292           17.48              5.47       22.95          69.50        -46.55          Peak

Remark:
            1. Measuring frequencies from 9kHz to the 1GHz.
            2. Radiated emissions measured in frequency range from 9kHz to 1000MHz were made
            with an instrument using peak/quasi-peak/average detector mode.
            3. Measurements above show only up to 6 maximum emissions noted, or would be
            lesser, with “ N/A ” remark, if no specific emissions from the EUT are recorded (ie:
            margin>20dB from the applicable limit) and considered that's already beyond the
            background noise floor.
            4. Margin (dB) = Result (dBuV/m) – Limit (dBuV/m).
            5. 960kHz Limi t= 20log(24000/960)+40log(30/3)=67.96




                                                 Page 16                                        Rev.00


                Compliance Certification Services Inc.
                FCC ID: FSUGMZKI                                               Report No.: T121029D04-RP1



For 30MHz ~ 1GHz
Operation Mode:           Normal Link                Test Date:                   December 3, 2012
                            o
Temperature:              27 C                       Tested by:                   Shawn Wu
Humidity:                 53 % RH                    Polarity:                    Ver. / Hor.

                                                                                                Detector
Frequency       Reading     Factor      Actual FS      Limit 3m     Safe Margin    Ant.Pol.
                                                                                                 Mode
  (MHz)         (dBuV)       (dB)       (dBuV/m)       (dBuV/m)         (dB)        H/V
                                                                                                (PK/QP)
  33.2333        36.69          -7.29     29.40             40.00     -10.60           V         Peak
 144.7833        40.18       -12.84       27.34             43.50     -16.16           V         Peak
 299.9833        40.06       -11.18       28.88             46.00     -17.12           V         Peak
 432.5500        32.91          -8.98     23.93             46.00     -22.07           V         Peak
 500.4500        33.41          -8.13     25.28             46.00     -20.72           V         Peak
 600.6833        34.04          -7.13     26.91             46.00     -19.09           V         Peak

 144.7833        35.61       -12.84       22.77             43.50     -20.73           H         Peak
 259.5667        36.36       -12.38       23.98             46.00     -22.02           H         Peak
 288.6667        42.20       -11.34       30.86             46.00     -15.14           H         Peak
 322.6167        38.22       -10.77       27.45             46.00     -18.55           H         Peak
 384.0500        34.50          -9.84     24.66             46.00     -21.34           H         Peak
 414.7667        32.65          -9.33     23.32             46.00     -22.68           H         Peak

Remark:
            1. No emission found between lowest internal used / generated frequency to 30 MHz.
            (9kHz ~ 30MHz)
            2. Measuring frequencies from 30 MHz to the 1GHz.
            3. Radiated emissions measured in frequency range from 30 MHz to 1000MHz were
            made with an instrument using Peak detector mode.
            4. Data of measurement within this frequency range shown “ --- ” in the table above
            means the reading of emissions are attenuated more than 20dB below the permissible
            limits or the field strength is too small to be measured.
            5. The IF bandwidth of SPA between 30MHz to 1GHz was 100kHz.




                                                  Page 17                                            Rev.00


                Compliance Certification Services Inc.
                FCC ID: FSUGMZKI                                            Report No.: T121029D04-RP1



7.2. POWERLINE CONDUCTED EMISSIONS
LIMIT
For an intentional radiator which is designed to be connected to the public utility (AC) power
line, the radio frequency voltage that is conducted back onto the AC power line on any frequency
or frequencies within the band 150 kHz to 30 MHz shall not exceed 250 microvolts (The limit
decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz). The limits at
specific frequency range is listed as follows:
                                                                  Limits
        Frequency Range                                          (dBμV)
             (MHz)
                                               Quasi-peak                         Average
            0.15 to 0.50                        66 to 56*                         56 to 46*
             0.50 to 5                              56                                46
              5 to 30                               60                                50
Compliance with this provision shall be based on the measurement of the radio frequency
voltage between each power line (LINE and NEUTRAL) and ground at the power terminals.

TEST CONFIGURATION
 See test photographs attached in Appendix I for the actual connections between EUT and
 support equipment.

TEST PROCEDURE
 1. The EUT was placed on a table, which is 0.8m above ground plane.
 2. Maximum procedure was performed on the six highest emissions to ensure EUT
    compliance.
 3. Repeat above procedures until all frequency measured were complete.

TEST RESULTS
The initial step in collecting conducted data is a spectrum analyzer peak scan of the measurement
range. Significant peaks are then marked as shown on the following data page, and these signals
are then quasi-peaked.




                                                Page 18                                           Rev.00


                Compliance Certification Services Inc.
                FCC ID: FSUGMZKI                                                Report No.: T121029D04-RP1



TEST DATA
The initial step in collecting conducted data is a spectrum analyzer peak scan of the measurement
range. Significant peaks are then marked as shown on the following data page, and these signals
are then quasi-peaked.


Operation Mode:               Normal Link              Test Date:                December 7, 2012
Temperature:                  26°C                     Tested by:                Rex Huang
Humidity:                     60% RH

             QP        AV        Corr.      QP        AV        QP       AV       QP        AV
  Freq.
           Reading   Reading     factor    Result    Result    Limit    Limit   Margin    Margin   Note
 (MHz)
           (dBuV)    (dBuV)       (dB)    (dBuV)    (dBuV)    (dBuV)   (dBuV)    (dB)      (dB)

 0.1500     51.86     40.06      0.14     52.00     40.20     65.99    56.00     -13.99   -15.80    L1
 0.2100     44.67     32.47      0.13     44.80     32.60     63.20    53.21     -18.40   -20.61    L1
 0.3600     23.86     13.56      0.14     24.00     13.70     58.73    48.73     -34.73   -35.03    L1
 1.1400     21.16     19.26      0.14     21.30     19.40     56.00    46.00     -34.70   -26.60    L1
 2.6400     29.23     27.33      0.07     29.30     27.40     56.00    46.00     -26.70   -18.60    L1
 12.5100    38.97     35.27      0.33     39.30     35.60     60.00    50.00     -20.70   -14.40    L1

 0.1500     51.10     39.30      0.10     51.20     39.40     65.99    56.00     -14.79   -16.60    L2
 0.2100     45.30     33.50      0.10     45.40     33.60     63.20    53.21     -17.80   -19.61    L2
 0.3600     26.20     21.70      0.10     26.30     21.80     58.73    48.73     -32.43   -26.93    L2
 1.3500     23.54     19.94      0.06     23.60     20.00     56.00    46.00     -32.40   -26.00    L2
 2.7000     21.40     10.90      0.00     21.40     10.90     56.00    46.00     -34.60   -35.10    L2
 12.5100    42.30     38.40      0.10     42.40     38.50     60.00    50.00     -17.60   -11.50    L2

Remark:
           1. Measuring frequencies from 0.15 MHz to 30MHz.
           2. The emissions measured in frequency range from 0.15 MHz to 30MHz were made
              with an instrument using Quasi-peak detector and average detector.
           3. The IF bandwidth of SPA between 0.15MHz and 30MHz was 10kHz; the IF
              bandwidth of Test Receiver between 0.15MHz and 30MHz was 9kHz;
           4. L1 = Line One (Live Line) / L2 = Line Two (Neutral Line)




                                                    Page 19                                         Rev.00


             Compliance Certification Services Inc.
             FCC ID: FSUGMZKI                         Report No.: T121029D04-RP1



Test Plots
Conducted emissions (Line 1)




Conducted emissions (Line 2)




                                          Page 20                         Rev.00



Document Created: 2012-12-14 13:17:06
Document Modified: 2012-12-14 13:17:06

© 2024 FCC.report