testreport 15227

FCC ID: FSUGMZI4

Test Report

Download: PDF
FCCID_873512

                                                                         Report No. 07A304R-RFUSP03V01




                                       Test Report


                     Product Name            TwinTouch 750e Laser
                     Model No.               GK-070004/T
                     FCC ID.                 FSUGMZI4




              Applicant KYE SYSTEMS CORP. (Genius)
              Address         No.492 Sec.5, Chung Hsin Rd., San Chung,
                              Taipei Hsien, 24160, Taiwan. R.O.C.




                           Date of Receipt        Oct. 23, 2007

                           Issued Date            Nov. 08, 2007

                           Report No.            07A304R-RFUSP03V01




The Test Results relate only to the samples tested.
The test report shall not be reproduced except in full without the written approval of QuieTek Corporation.
This report must not be used to claim product endorsement by NVLAP any agency of the U.S. Government



                                          Page : 1 of 23                                       Version:1.0


                                                                           Report No. 07A304R-RFUSP03V01




                         Test Report Certification
                                                                       Test Date: Nov. 08, 2007
                                                                       Report No.: 07A304R-RFUSP03V01




     Product Name                 TwinTouch 750e Laser

     Applicant                    KYE SYSTEMS CORP. (Genius)

     Address                      No.492 Sec.5, Chung Hsin Rd., San Chung, Taipei Hsien,

                                  24160, Taiwan. R.O.C.

     Manufacturer                 KYE SYSTEMS CORP. (Genius)

     Model No.                    GK-070004/T

     FCC ID.                      FSUGMZI4

     Rated Voltage                AC 120V/60Hz

     EUT Working Voltage          DC 3V

     Trade Name                   Genius

     Applicable Standard          FCC CFR Title 47 Part 15 Subpart C: 2006

                                  ANSI C63.4: 2003

                                  CISPR 22: 2005

     Test Result                  Complied

The Test Results relate only to the samples tested.
The test report shall not be reproduced except in full without the written approval of QuieTek Corporation.
This report must not be used to claim product endorsement by NVLAP any agency of the U.S. Government



          Documented By            :
                                       (   Senior Engineering Adm. Specialist /
                                                    Anita Chou     )
                                                                                        0914
          Tested By                :
                                           ( E n g i n e e r / T i m S u n g)

          Approved By              :

                                           ( Deputy Manager / Vincent Lin)


                                             Page : 2 of 23                                     Version:1.0


                                                                                                           Report No. 07A304R-RFUSP03V01



                                          TA B L E O F C O N T E N T S
  Description                                                                                                                                                Page
1.              GENERAL INFORMATION.......................................................................................................4
1.1.            EUT Description ..........................................................................................................................4
1.2.            Operational Description .............................................................................................................5
1.3.            Test System Details ....................................................................................................................6
1.4.            Configuration of Test System ....................................................................................................6
1.5.            EUT Exercise Software..............................................................................................................7
1.6.            Test Facility ..................................................................................................................................8
2.              Conducted Emission ...............................................................................................................9
2.1.            Test Equipment ...........................................................................................................................9
2.2.            Test Setup ....................................................................................................................................9
2.3.            Limits.............................................................................................................................................9
2.4.            Test Procedure ..........................................................................................................................10
2.5.            Uncertainty.................................................................................................................................10
2.6.            Test Data of Conducted Emission ..........................................................................................10
3.              Radiated Emission .................................................................................................................11
3.1.            Test Equipment .........................................................................................................................11
3.2.            Test Setup ..................................................................................................................................11
3.3.            Limits...........................................................................................................................................12
3.4.            Test Procedure ..........................................................................................................................13
3.5.            Uncertainty.................................................................................................................................13
3.6.            Test Data of Radiated Emission .............................................................................................14
4.              Band Edge ................................................................................................................................18
4.1.            Test Equipment .........................................................................................................................18
4.2.            Test Setup ..................................................................................................................................18
4.3.            Limit ............................................................................................................................................19
4.4.            Test Procedure ..........................................................................................................................19
4.5.            Test Result of Band Edge........................................................................................................20
5.              EMI Reduction Method During Compliance Testing .....................................................21
Attachment 1:     EUT Test Photographs
Attachment 2:     EUT Detailed Photographs




                                                            Page : 3 of 23                                                                   Version:1.0


                                                                 Report No. 07A304R-RFUSP03V01


1.      GENERAL INFORMATION

1.1.    EUT Description

        Product Name           TwinTouch 750e Laser
        Trade Name             Genius
        FCC ID.                FSUGMZI4
        Model No.              GK-070004/T
        EUT Working Voltage DC 3V
        Frequency Range        27.045MHz
        Type of Modulation     FSK
        Type of antenna        Loop Antenna
        Number of Channel      1
        Channel Control        Manual


         Frequency of Each Channel:
           Channel         Frequency
          Channel 01:     27.045 MHz


       Note:
         1.    The EUT is a TwinTouch 750e Laser used in household and office PC system or
               related application.
         2.    These tests were conducted on a sample of the equipment for the purpose of
               demonstrating compliance with FCC CFR Title 47 Part 15 Subpart C Paragraph
               15.227.




                                        Page : 4 of 23                              Version:1.0


                                                                Report No. 07A304R-RFUSP03V01




1.2.   Operational Description

       The EUT is a TwinTouch 750e Laser used in household and office PC system. The number of
       the channels is 1 in 27.045MHz.
       The device adapts FSK modulation. The loop antenna provides diversity function to improve
       the transmitting function.


       Test Mode         Mode 1: Transmitter




                                        Page : 5 of 23                              Version:1.0


                                                                       Report No. 07A304R-RFUSP03V01




1.3.    Test System Details

        The types for all equipment, plus descriptions of all cables used in the tested system
        (including inserted cards) are:

       Product          Manufacturer     Model No.        Serial No.      FCC ID       Power Cord
                                                 N/A


Signal Cable Type                                      Signal cable Description
                                                 N/A



1.4.    Configuration of Test System



                                                EUT




                                        Page : 6 of 23                                   Version:1.0


                                                               Report No. 07A304R-RFUSP03V01



1.5.   EUT Exercise Software

       1   Setup the EUT as shown in section 1.4.
       2   Press and hold the left and the middle button.
       3   Install the batteries.
       4   Check that the cursor moves circularly on the notebook.
       5   Remove the notebook and start the tests.




                                     Page : 7 of 23                             Version:1.0


                                                                   Report No. 07A304R-RFUSP03V01




1.6.   Test Facility

       Ambient conditions in the laboratory:
                 Items               Required (IEC 68-1)           Actual
       Temperature (°C)          15-35                     20-35
       Humidity (%RH)            25-75                     30-65
       Barometric pressure (mbar) 860-1060                 950-1000


       Site Description: Federal Communications Commission
                         FCC Engineering Laboratory
                         7435 Oakland Mills Road
                         Columbia, MD 21046
                         Reference 31040/SIT1300F2


                          Accreditation on NVLAP
                          NVLAP Lab Code: 200533-0


       Site Name:         Quietek Corporation
       Site Address:      No. 5-22, Ruei-Shu Valley, Ruei-Ping Tsuen,
                          Lin-Kou Shiang, Taipei,
                          Taiwan, R.O.C.
                          TEL: 886-2-8601-3788 / FAX : 886-2-8601-3789
                          E-Mail : service@quietek.com                        0914

       FCC Accreditation Number: TW1014




                                         Page : 8 of 23                              Version:1.0


                                                                               Report No. 07A304R-RFUSP03V01


2.     Conducted Emission

2.1.   Test Equipment

       The following test equipment are used during the conducted emission test:

       Item Instrument          Manufacturer Type No./Serial No                  Last Cal.     Remark
       1     Test Receiver R & S                      ESCS 30/838251/001         May, 2007
       2     L.I.S.N.           R&S                   ESH3-Z5/836679/0023        May, 2007     EUT
       3     L.I.S.N.           R&S                   ENV 4200/833209/0023 May, 2007           Peripherals
       4     Pulse Limiter R & S                      ESH3-Z2                    May, 2007
       6     No.1 Shielded Room
       Note: All equipments are calibrated every one year.


2.2.   Test Setup

                                                                     Reference Plane

                     Test Receiver
                                                                                        40cm


                   12dBuV                                           EUT
                   †††                                      Load
                   †††




                                                    LISN                                LISN


                                                                       LISN
                                     Ground Plane


2.3.   Limits

                        FCC Part 15 Subpart C Paragraph 15.207 (dBuV) Limit

                         Frequency                                 Limits

                            MHz
                                                            QP                     AV

                         0.15 - 0.50                       66-56                 56-46

                          0.50-5.0                          56                     46

                          5.0 - 30                          60                     50

                 Remarks : In the above table, the tighter limit applies at the band edges.


                                                Page : 9 of 23                                    Version:1.0


                                                                    Report No. 07A304R-RFUSP03V01




2.4.   Test Procedure

       The EUT and simulators are connected to the main power through a line impedance
       stabilization network (L.I.S.N.).   This provides a 50 ohm /50uH coupling impedance for
       the measuring equipment. The peripheral devices are also connected to the main power
       through a LISN that provides a 50ohm/50uH coupling impedance with 50ohm termination.
       (Please refer to the block diagram of the test setup and photographs.)
       Both sides of A.C. line are checked for maximum conducted interference. In order to find
       the maximum emission, the relative positions of equipment and all the interface cables
       must be changed according to ANSI C63.4: 2003 on conducted measurement.
       Conducted emissions were invested over the frequency range from 0.15MHz to 30MHz
       using a receiver bandwidth of 9kHz.



2.5.   Uncertainty

       ± 2.26 dB



2.6.   Test Data of Conducted Emission

       The EUT is powered by batteries Owing to the DC operation. This test item is not performed




                                           Page : 10 of 23                             Version:1.0


                                                                                  Report No. 07A304R-RFUSP03V01


3.     Radiated Emission

3.1.   Test Equipment

       The following test equipment are used during the radiated emission test:

       Test Site            Equipment        Manufacturer       Model No./Serial No.                 Last Cal.
        Site # 1 Test Receiver     R&S                       ESVS 10 / 834468/003                    May, 2007
                 Spectrum Analyzer Advantest                 R3162/ 00803480                         May, 2007
                      Pre-Amplifier         Advantest        BB525C/ 3307A01812                      May, 2007
                      Bilog Antenna         SCHAFFNER CBL6112B / 2697                               Sep., 2007
        Site # 2 Test Receiver     R&S                       ESCS 30 / 836858 / 022                  May, 2007
                 Spectrum Analyzer Advantest                 R3162 / 100803466                       May, 2007
                      Pre-Amplifier         Advantest        BB525C/3307A01814                       May, 2007
                      Bilog Antenna         SCHAFFNER CBL6112B / 2705                                May, 2007
                      Horn Antenna          ETS              3115 / 0005-6160                       Sep., 2007
                 Pre-Amplifier     QTK                       QTK-AMP-01/ 0001                        May, 2007
        Site # 3 Test Receiver     R&S                       ESI 26 / 838786/004                     May, 2007
                 Spectrum Analyzer Agilent                   E4407B / US39440758                     May, 2007
                      Bilog Antenna         SCHAFFNER CBL6112B / 2697                                May, 2007
                      Horn Antenna          Schwarzbeck BBHA9120D / 305, 306                         July, 2007
                      Horn Antenna          Schwarzbeck BBHA9170 / 208, 209                          July, 2007
                      Pre-Amplifier         QTK         QTK-AMP-01 / 0001                            July, 2007
                      Pre-Amplifier         QTK              QTK-AMP-03 / 0003                       May, 2007
                      Pre-Amplifier         HP               8449B / 3008A01123                      July, 2007
       Note:           1. All equipments are calibrated every one year.
                       2. The test instruments marked by “X” are used to measure the final test results.


3.2.   Test Setup
                                                                    3m


                       FRP Dome
                                                                                                           1m to 4m




                                                                         The height of board
                                                                         band or Dipole
                                                                         Antenna was scanned
                                                                         from 1M to 4M.
                                                                         The distance between
                                                                         antenna and turn table
                                                                         was 10M to3M
                                      EUT                                regards to the standard
               Non-Conducted Table                                       adopted.

                                                80cm


                                                         Fully soldered Metal Ground               To Controller
                   Test                                                                                To Receiver
                 Receiver




                                              Page : 11 of 23                                               Version:1.0


                                                                     Report No. 07A304R-RFUSP03V01




3.3.   Limits

       ¾ FCC Part 15 Subpart C Paragraph 15.227 Limit


                         FCC Part 15 Subpart C Paragraph 15.227 Limits

                                                    Field strength of fundamental
                   Fundamental Frequency
                          MHz
                                                      uV/m               dBuV/m
                        26.96-27.28                   10000                80.0
       Remarks :
                   1. RF Voltage (dBuV) = 20 log RF Voltage (uV)
                   2. Distance refers to the distance in meters between the measuring instrument
                      antenna and the closed point of any part of the device or system.
                   3. The emission limit in this paragraph is based on measurement instrumentation
                      employing an average detector. Measurement using instrumentation with a
                      peak detector function, corresponding to 20dB above the maximum permitted
                      average limit.


       ¾ Frequencies in restricted band are complied to limits on Paragraph 15.209.


                        FCC Part 15 Subpart C Paragraph 15.209 Limits
                     Frequency
                        MHz                 uV/m @3m                dBuV/m@3m

                       30-88                    100                      40

                      88-216                    150                     43.5

                      216-960                   200                      46

                     Above 960                  500                      54
       Remarks : 1. RF Voltage (dBuV/m) = 20 log RF Voltage (uV/m)
                   2. In the Above Table, the tighter limit applies at the band edges.
                   3. Distance refers to the distance in meters between the measuring instrument
                       antenna and the closed point of any part of the device or system.




                                        Page : 12 of 23                                  Version:1.0


                                                                   Report No. 07A304R-RFUSP03V01




3.4.   Test Procedure

       The EUT and its simulators are placed on a turn table which is 0.8 meter above ground.
       The turn table can rotate 360 degrees to determine the position of the maximum emission
       level. The EUT was positioned such that the distance from antenna to the EUT was 3
       meters.
       The antenna can move up and down between 1 meter and 4 meters to find out the
       maximum emission level.
       Both horizontal and vertical polarization of the antenna are set on measurement. In order
       to find the maximum emission, all of the interface cables must be manipulated according
       to
       ANSI C63.4: 2003 on radiated measurement.
       Radiated emissions were invested over the frequency range from 30MHz to1GHz using a
       receiver bandwidth of 120kHz. Radiated was performed at an antenna to EUT distance of
       3 meters.
       The frequency range from 30MHz to 10th harminics is checked.
       Below 30MHz the magnetic loop antenna was used.

3.5.   Uncertainty

       ± 3.9 dB above 1GHz
       ± 3.8 dB below 1GHz




                                       Page : 13 of 23                                 Version:1.0


                                                                   Report No. 07A304R-RFUSP03V01




3.6.    Test Data of Radiated Emission

        Product      :      TwinTouch 750e Laser
        Test Item    :      Fundamental Radiated Emission
        Test Site    :      No.3 OATS
        Test Voltage :      AC 120V/60Hz
        Test Mode :         Mode 1: Transmitter




Polarity Frequency       Correct   Reading Level Measure Level   Margin    Peak Limit Average Limit
             (MHz)       Factor       (dBuV)       (dBuV/m)       (dB)     (dBuV/m)    (dBuV/m)
                          (dB)
Peak Detector
   X         27.048      20.190       44.560         64.750      -35.250    100.000      80.000
   Y         27.048      20.190       43.470         63.660      -36.340    100.000      80.000
   Z         27.048      20.190       42.850         63.040      -36.960    100.000      80.000


Polarity X




                                          Page : 14 of 23                             Version:1.0


                                                              Report No. 07A304R-RFUSP03V01


Polarity Y




Polarity Z




Note:
        1.   Below 30MHz, the magnetic loop antenna was used.
        2.   Only fundamental frequency is shown on the test report.
        3.   For those measured radiated emissions below 30MHz, not shown above, mean they
             are below the limit.
        4.   Correct factor = Antenna Factor + Cable Loss – Pre-amplifier Gain




                                    Page : 15 of 23                             Version:1.0


                                                                        Report No. 07A304R-RFUSP03V01




             Product      :      TwinTouch 750e Laser
             Test Item    :      General Radiated Emission
             Test Site    :      No.3 OATS
             Test Voltage :      AC 120V/60Hz
             Test Mode :         Mode 1: Transmitter


  Frequency               Correct          Reading       Measurement        Margin          Limit
                              Factor         Level              Level
        MHz                    dB            dBuV            dBuV/m          dB           dBuV/m
  Horizontal
    80.541                    8.982         16.196           25.178        -14.822         40.000
    107.567               13.064             6.613           19.677        -23.823         43.500
    137.970               12.444             8.870           21.313        -22.187         43.500
    568.457               19.179            11.051           30.230        -15.770         46.000
    622.886               20.811            12.402           33.213        -12.787         46.000
    650.100               20.899            12.916           33.815        -12.185         46.000




Note:
        1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average
           measurements as necessary.
        2. “    ” means the worst emission level.
        3. Measurement Level = Reading Level + Correct Factor
        4. Correct Factor = Antenna Factor + Cable Loss – Pre-amplifier Gain




                                              Page : 16 of 23                            Version:1.0


                                                                     Report No. 07A304R-RFUSP03V01




         Product      :      TwinTouch 750e Laser
         Test Item    :      General Radiated Emission
         Test Site    :      No.3 OATS
         Test Voltage :      AC 120V/60Hz
         Test Mode :         Mode 1: Transmitter


   Frequency           Correct          Reading       Measurement        Margin           Limit
                          Factor         Level              Level
        MHz                dB            dBuV            dBuV/m            dB           dBuV/m
   Vertical
    84.429                8.727          11.395             20.122       -19.878         40.000
    134.970               11.835         10.237             22.071       -21.429         43.500
    199.011               9.619          12.458             22.077       -21.423         43.500
    568.457               21.207         4.427              25.633       -20.367         46.000
    622.879               21.211         6.438              27.649       -18.351         46.000
    650.100               20.119         9.896              30.015       -15.985         46.000




Note:
          1.    All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or
                 average measurements as necessary.
          2.   “    ” means the worst emission level.
          3.   Measurement Level = Reading Level + Correct Factor
          4.   Correct factor = Antenna Factor + Cable Loss – Pre-amplifier Gain




                                          Page : 17 of 23                             Version:1.0


                                                                                Report No. 07A304R-RFUSP03V01


4.     Band Edge

4.1.   Test Equipment

       The following test equipment are used during the radiated emission test:

        Test Site              Equipment       Manufacturer       Model No./Serial No.                Last Cal.
         Site # 1 Test Receiver               R&S              ESVS 10 / 834468/003                  July, 2007
                  Spectrum Analyzer           Advantest        R3162/ 00803480                       May, 2007
                      Pre-Amplifier           Advantest        BB525C/ 3307A01812                    May, 2007
                      Bilog Antenna           SCHAFFNER CBL6112B / 2697                             Nov., 2007
         Site # 2 Test Receiver               R&S              ESCS 30 / 836858 / 022               Nov., 2007
                  Spectrum Analyzer           Advantest        R3162 / 100803466                     May, 2007
                      Pre-Amplifier           Advantest        BB525C/3307A01814                     May, 2007
                      Bilog Antenna           SCHAFFNER CBL6112B / 2705                              Oct., 2007
         Site # 3 Test Receiver               R&S              ESI 26 / 838786 / 004                 May, 2007
                  Spectrum Analyzer           HP               E4407B / US39440758                   May, 2007
                      Pre-Amplifier           QTK              QTK-AMP-03 / 0003                     May, 2007
                      Broadband Antenna Schwarzbeck VULB9166/1085                                   April, 2007
                      Horn Antenna            ETS              3115 / 0005-6160                      July, 2007
                      Loop Antenna            R&S              HFH2-Z2/833799/004                    July, 2007
                      Pre-Amplifier           QTK              QTK-AMP-01 / 0001                     July, 2007
       Note:         1. All equipments are calibrated every one year.
                     2. The test instruments marked by “X” are used to measure the final test results.



4.2.   Test Setup

       RF Radiated Measurement:

                                                                3m

                      FRP Dome                                                                      1m to 4m



                                                                     The height of board
                                                                     band or Horn
                                                                     Antenna was scanned
                                                                     from 1M to 4M.
                                                                     The distance between
                                                                     antenna and turn
                                    EUT                              table was 3M regards
               Non-Conducted                                         to the standard
               Table                                                 adopted.
                                             80cm

                                                      Fully soldered Metal Ground           To Controller
                  Test                                                                          To Receiver
                Receiver




                                            Page : 18 of 23                                             Version:1.0


                                                                     Report No. 07A304R-RFUSP03V01


4.3.   Limit

       Attenuation below the general limits specified in Section 15.209(a) is not required. In addition,
       radiated emissions which fall in the restricted bands, as defined in Section 15.205(a), must
       also comply with the radiated emission limits specified in Section 15.209(a) (see Section
       15.205(c)).

4.4.   Test Procedure

       The EUT and its simulators are placed on a turn table which is 0.8 meter above ground.
       The turn table can rotate 360 degrees to determine the position of the maximum emission
       level. The EUT was positioned such that the distance from antenna to the EUT was 3
       meters.
       The antenna can move up and down between 1 meter and 4 meters to find out the
       maximum emission level.
       Both horizontal and vertical polarization of the antenna are set on measurement. In order
       to find the maximum emission, all of the interface cables must be manipulated according
       to
       ANSI C63.4: 2003 on radiated measurement.
       The additional latch filter below 1GHz was used to measure the level of harmonics radiated
       emission during field dtrength of harmonics measurement.
       The bandwidth below 30MHz setting on the field strength meter is 10 kHz




                                        Page : 19 of 23                                   Version:1.0


                                                                                               Report No. 07A304R-RFUSP03V01


4.5.      Test Result of Band Edge

          Product               :      TwinTouch 750e Laser
          Test Item             :      Band Edge
          Test Site             :      No.3 OATS
          Test Mode             :      Mode 1: Transmitter


       RF Radiated Measurement: (Peak Detector)
         Frequency                  Correct Factor     Reading Level        Measure Level               Margin (dB)              Limit
           (MHz)                        (dB)                (dBuV)               (dBuV/m)                                   (dBuV/m)
           25.636                      20.230               28.440                48.670                  -25.330               74.000


                                                                      Det         MA/AV           Trd
                 Att 10 dB                                            ResBW       9 kHz
                        INPUT 1                                       Meas T     100 ms           Unit          dBÌ V/m


                  FREQUENCY                                     27.0480000 MHz
                  LEVEL PK+                                      44.56 dB Ì V/m
                         AV                                      43.03 dB Ì V/m


             10                20          30        40          50         60            70             80          90




                                        Marker 1 [T1]
                                                43.59 dBÌ V/m
                                             27.04800000 MHz
           100
                                                                                  1 [T1]          43.59 dBÌ V/m
            90                                                                                 27.04800000 MHz
                                                                                  2 [T1]          25.33 dBÌ V/m
            80
                                                                                               25.50000000 MHz
            70                                                                    3 [T1]          25.46 dBÌ V/m
                                                                                               25.66800000 MHz
            60
                                                                                  4 [T1]          28.44 dBÌ V/m
            50                                                                                 1
                                                                                               25.63600000 MHz
            40
                      4
            302           3
                                                                                                                          1MA
            20

            10
             0
                 25.5 MHz                                                                                     27.5 MHz
          Date:               6.NOV.2007    22:03:03




                                                          Page : 20 of 23                                                       Version:1.0


                                                      Report No. 07A304R-RFUSP03V01




5.   EMI Reduction Method During Compliance Testing



     No modification was made during testing.




                                    Page : 21 of 23                    Version:1.0



Document Created: 2007-11-26 11:37:02
Document Modified: 2007-11-26 11:37:02

© 2024 FCC.report