RF Exposure information - MPE Report Rev.1.pdf

FCC ID: FSUGG00A2

RF Exposure Info

Download: PDF
FCCID_2976039

                    Test Report No.: FS160129N009


                                    RF EXPOSURE REPORT
   Applicant                        KYE SYSTEMS CORP

   Address                          No. 492, Sec 5, Chongxin Rd., Sanchong Dist., New Taipei City 24160, Taiwan (R.O.C)


   Manufacturer or
                                    Dongguan Kunying Computer Products Co., Ltd
   Supplier
                                    Baodun Industrial District, Houjie Town, Dongguan City, Guangdong Province, 523961
   Address
                                    China

   Product                          Bluetooth Speaker

   Brand Name                       Genius

   Model                            SP-906BT Plus

   Additional Model &
                                    SP-906BT
   Model Difference

   Date of tests                    Jan. 29, 2016 ~ Mar. 10, 2016

        FCC Part 2 (Section 2.1091)
        KDB 447498 D01
        IEEE C95.1

   CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                        Tested by Blue Zheng                                                              Approved by Chris Chen
                 Project Engineer / EMC Department                                                 Assistant Manager / EMC Department




                                                                                                                 Date: Mar. 10, 2016
   This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
   only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
   report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
   unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
   provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
   however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
   shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
   mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification




                                                     No. 34, Chenwulu Section, Guantai Rd., Houjie               Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                     Town, Dongguan City,                                        Fax: +86 769 8593 1080
Dongguan Branch
                                                     Guangdong 523942, China                                     Email: customerservice.dg@cn.bureauveritas.com
                                                                           Page 1 of 6                                                              Report Version 1


                Test Report No.: FS160129N009

                                          Table of Contents
   RELEASE CONTROL RECORD ................................................................................ 3
   1.       CERTIFICATION .............................................................................................. 4
   2.       RF EXPOSURE DEFINE ................................................................................. 5
   3.       CLASSIFICATION ........................................................................................... 5
   4.       SAR TEST EXCLUSION THRESHOLDS ........................................................ 6




                                         No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                         Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                         Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                           Page 2 of 6                                                   Report Version 1


                Test Report No.: FS160129N009


                               RELEASE CONTROL RECORD

    ISSUE NO.                REASON FOR CHANGE                                                      DATE ISSUED

      FS160129N009           Original release                                                         Mar. 10, 2016




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 3 of 6                                                    Report Version 1


                Test Report No.: FS160129N009

   1. CERTIFICATION


                        FCC ID:     FSUGG00A2

                   PRODUCT:         Bluetooth Speaker
              BRAND NAME:           Genius
                 MODEL NO.:         SP-906BT Plus
         ADDITIONAL NO.:            SP-906BT
             TEST SAMPLE:           Engineering Sample

                 APPLICANT:         KYE SYSTEMS CORP

               STANDARDS:           FCC Part 2 (Section 2.1091)

                                    KDB 447498 D01

                                    IEEE C95.1




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                     Page 4 of 6                                                    Report Version 1


                Test Report No.: FS160129N009

   2. RF EXPOSURE DEFINE
   The corresponding SAR Exclusion Threshold condition, listed below:

   1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
     ≤ 50 mm are determined by:
     [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
     mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,16 where
          f(GHz) is the RF channel transmit frequency in GHz
        Power and distance are rounded to the nearest mW and mm before calculation
          The result is rounded to one decimal place for comparison
     The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and
     for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation
     distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion.
   2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold
     is determined according to the following:
     a) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·( f(MHz)/150)] mW, at
       100MHz to 1500 MHz
     b) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·10] mW at > 1500 MHz and ≤
       6 GHz
   3) At frequencies below 100 MHz, the following may be considered for SAR test exclusion.
     a) The threshold at the corresponding test separation distance at 100 MHz in step 2) is multiplied by
       [1 + log(100/f(MHz))] for test separation distances > 50 mm and < 200 mm.
     b) The threshold determined by the equation in a) for 50 mm and 100 MHz is multiplied by ½ for test
       separation distances ≤ 50 mm.
     c) SAR measurement procedures are not established below 100 MHz. When SAR test exclusion
       cannot be applied, a KDB inquiry is required to determine SAR evaluation requirements for any
       test results to be acceptable.


   3. CLASSIFICATION
   The antenna of this product, under normal use condition, is at less than 20cm away
   from the body of the user. So, this device is classified as Portable Device.




                                     No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                     Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                     Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 5 of 6                                                    Report Version 1


                Test Report No.: FS160129N009



   4. SAR TEST EXCLUSION THRESHOLDS
   According to the KDB 447498:
   The maximun Peak output power specified is 3.50dBm = 2.239mW


   The SAR Exclusion Threshold Level:
   = 3.0 * (min. test separation distance, mm) / sqrt(freq. in GHz)
   = 3.0 * 5 / sqrt (2.480) mW
   = 9.53 mW


   Since the source-based time-averaging conducted output power is well below the SAR
   low threshold level, so the EUT is considered to comply with SAR requirement without
   testing.




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                     Page 6 of 6                                                    Report Version 1



Document Created: 2016-04-29 09:18:10
Document Modified: 2016-04-29 09:18:10

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC