WITH SETUP PHOTOS

FCC ID: FI7R8ER00

Test Report

Download: PDF
FCCID_84179

Product                   : Smart Card Reader
Applicant                 : Archtek Telecom Corporation.
FCC ID                    : FI7R8ER00
Model                     : SCR2000E
Report No.                : MLT9912P15003
Test Date                 : December 25.1999




Test By
               Max Light Technology Co.,Ltd.
          Room 5, 8F, No.125, Section 3 Roosevelt Road,
                     Taipei, Taiwan., R.O.C.
             Tel: 886-2-2363-2447 Fax: 886-2-2363-2597

   The test report consists of 20 pages in total. It may be duplicated completely
    for legal use with the allowance of the applicant. It shall not be reproduced
            except in full, without the written approval of our laboratory.


                         MAX LIGHT
                        MEASUREMENT REPORT         Page: 2/20
   Technology Lab


Table of Contents :
I. General                                                  4.

II. Conducted Emissions Requirements                        8.

III. Radiated Emissions Requirements                        12.

Appendix I (EUT Test Setup)                                 19.




Report Number: MLT9912P15003            FCC ID: FI7R8ER00


                        MAX LIGHT
                      MEASUREMENT REPORT                   Page: 3/20
   Technology Lab

                      CERTIFICATION

 We here by verify that :

       The test data, data evaluation, test procedures and equipment
 configurations shown in this report were made in accordance with the
 procedures given in ANSI C63.4-1992. All test were conducted by
 MLT(Max Light Technology Co.,Ltd) Room 5, 8F, No.125, Section 3
 Roosevelt Road, Taipei, Taiwan, R.O.C Also, we attest to the accuracy of
 each.
       We further submit that the energy emitted by the sample EUT tested
as described in the report is in compliance with Class B radiated and
conducted emission limit of FCC Rules Part 15 Subpart B.


 EUT                  : Smart Card Reader

 Applicant            : Archtek Telecom Corporation.
                            4F,No.9,Lane 130,Min-Chyuan Rd.,
                            Hsin-Tien,Taipei, Taiwan

 Manufacturer         : Archtek Telecom Corporation.
                            4F,No.9,Lane 130,Min-Chyuan Rd.,
                            Hsin-Tien,Taipei, Taiwan

 Model No             : SCR2000E

 FCC ID               : FI7R8ER00




 Prepared by :                      Approved by :
                   Country Huang                      Roger Chen


 Report Number: MLT9912P15003                   FCC ID: FI7R8ER00


                       MAX LIGHT
                     MEASUREMENT REPORT                    Page: 4/20
  Technology Lab

I. GENERAL

1.1 Introduction
     The following measurement report is submitted on behalf of Archtek
Telecom Corporation. In support of a Class B Digital Device certification
in accordance with Part2 Subpart J and Part 15 Subpart A And B of the
Commission’s and Regulations.


1.2 Description of EUT

EUT                  : Smart Card Reader

Applicant            : Archtek Telecom Corporation.
                           4F,No.9,Lane 130,Min-Chyuan Rd.,
                           Hsin-Tien,Taipei, Taiwan

Manufacturer         : Archtek Telecom Corporation.
                           4F,No.9,Lane 130,Min-Chyuan Rd.,
                           Hsin-Tien,Taipei, Taiwan

Model No             : SCR2000E

FCC ID               : FI7R8ER00

Power Type           : Powered by PC

PS2 Cable            : PS2 Connectorx1 (Shielded, 93 cm long)

RS-232 Cable         : 9Pin RS-232 Connectorx1 (Shielded, 65 cm long)

          During testing the EUT was operated at “Read data of IC Card”
mode for each emission measured(P.S Run “Test Software” in Dos Mode).
This was done in order to ensure that maximum emission levels were
attained.


Report Number: MLT9912P15003                   FCC ID: FI7R8ER00


                        MAX LIGHT
                      MEASUREMENT REPORT                 Page: 5/20
  Technology Lab

1.3 Description of Support Equipment
       In order to construct the minimum system which required by
the ANSI C63.4-1991, following equipments were used as the support
units.

Computer        :   COMPAQ
Model No.       :   3284
Serial No.      :   L708BKTB4154
FCC ID          :   EJH3284

Keyboard        :   COMPAQ
Model No.       :   KPQ-E99ZC-13
Serial No.      :   237743-334
FCC ID          :   CMYKPQ7285

Monitor         :   COMPAQ
Model No.       :   303U
Serial No.      :   704AG19TG099
FCC ID          :   BJMCM14UH

Mouse           :   COMPAQ
Model No.       :   196694-301
Serial No.      :   1SH67CHE03360
FCC ID          :   EMJMUSJJ

Printer         :   PANASONIC
Model No.       :   KX-P1080I
Serial No.      :   7CKAKE98933
FCC ID          :   ACJ5Z6KX-P10801




Report Number: MLT9912P15003                  FCC ID: FI7R8ER00


                         MAX LIGHT
                        MEASUREMENT REPORT                       Page: 6/20
  Technology Lab

1.4 Configuration of System Under Test


                                 Power Supply
                                          RS-232   PS2 Cable
                       RS-232




             Printer
                                      Monitor
                                                           EUT

                                PC


                                     Keyboard


                       Mouse



      During testing the EUT(Smart Card Reader ) was connected to the
Compaq PC’s PS2 port and RS-232 port. So there is no need for additional
I/O card. A mouse was connected to the PS2 port of PC and a printer was
connected to the parallel port of PC. A keyboard was connected to the
other PS2 port of PC.




Report Number: MLT9912P15003                       FCC ID: FI7R8ER00


                      MAX LIGHT
                     MEASUREMENT REPORT                   Page: 7/20
  Technology Lab

1.5 Test Procedure
      All measurements contained in this report were performed according
to the techniques described in Measurement procedure ANSI C63.4-1992
"Measurement of unIntentional Radiators."


1.6 General Test Condition
      The conditions under which the EUT operates were varied to
determine their effect on the equipment's emission characteristics. The
final configuration of the test system and the mode of operation used
during these tests was chosen as that which produced the highest
emission levels. However, only those conditions which the EUT was
considered likely to encounter in normal use were investigated. The
system's radiated and conducted emissions were investigated while the
EUT alternately transferred data (IC Card’s Data) to the computer. Run
“Test Software” which read continuous data of IC Card form EUT . The
EUT was proven to worst case emissions. The system's physical layout
and cabling was randomly arranged to ensure that maximum emission
levels were attained.




Report Number: MLT9912P15003                   FCC ID: FI7R8ER00


                       MAX LIGHT
                      MEASUREMENT REPORT                    Page: 8/20
     Technology Lab


II. Conducted Emissions Requirements

2.1 General & Setup :

     The power line conducted emission measurements were performed in
a shielded enclosure. The EUT was assembled on a wooden table which is
80 centimeters high, was placed 40 centimeters from the backwall and at
least 1 meter from the sidewall.

     Power was fed to the EUT from the public utility power grid through a
line filter and EMCO Model 3825/2 Line Impedance Stabilization Networks
(LISN). The LISN housing, measuring instrumentation case, ground plane,
etc., were electrically bonded together at the same RF potential. The
Spectrum analyzer was connected to the AC line through an isolation
transformer. The 50-ohm output of the LISN was connected to the
spectrum analyzer directly. Conducted emission levels were in the
CISPER quasi-peak detection mode. The analyzer's 6 dB bandwidth was
set to 9 KHz. No post-detector video filter was used.

     The spectrum was scanned from 450 KHz to 30 MHz. The physical
arrangement of the test system and associated cabling was varied (within
the scope of arrangements likely to be encountered in actual use) to
determine the effect on the unit's emanations in amplitude and frequency.
All spurious emission frequencies were observed. The highest emission
amplitudes relative to the appropriate limit were measured and have been
recorded in paragraph 2.6.




2.2 Test Equipment List:

A.   EMCO 3825/2 LISN (S/N:2654)
B.   EMCO 3825/2 LISN (S/N:2658)
C.   HP 8591EM 9KHZ-1.8GHz Spectrum Analyzer (S/N:73412A00110)
D.   Shielded Room (MLT-SR1)



Report Number: MLT9912P15003                    FCC ID: FI7R8ER00


                     MAX LIGHT
                    MEASUREMENT REPORT               Page: 9/20
  Technology Lab


2.3 Test Configuration:




              Front View of The Test Configuration




Report Number: MLT9912P15003             FCC ID: FI7R8ER00


                     MAX LIGHT
                    MEASUREMENT REPORT              Page: 10/20
  Technology Lab




              Rear View of The Test Configuration




Report Number: MLT9912P15003            FCC ID: FI7R8ER00


                      MAX LIGHT
                      MEASUREMENT REPORT                 Page: 11/20
  Technology Lab


2.4 Test condition:

 EUT tested in accordance with the specifications given by the
manufacturer , and exercised in the most unfavorable manner.



2.5 Conducted Emissions Limits:


Frequency range (MHz)                 Limits (dBuV)
       0.45 to 30                           47.9




Report Number: MLT9912P15003                 FCC ID: FI7R8ER00


                            MAX LIGHT
                        MEASUREMENT REPORT                   Page: 12/20
  Technology Lab


2.6 Measurement Data Of Conducted Emissions:

   The following table show a summary of the highest emissions of power
line conducted emissions to the HOT and NATURAL conductor of the EUT
power.


Applicant              : Archtek Telecom Corporation..
Model No               : SCR2000E
EUT                    : Smart Card Reader

            Power Line Conducted Emissions (Class B)
Conductor        Frequency       Peak Amplitude          Limits
                   (MHz)             (dBuV)              (dBuV)
                    0.45               31.16              47.9
                    6.78               32.82              47.9
                    11.57              34.71              47.9
    L1              16.72              35.19              47.9
                    19.58              39.67              47.9
                    26.91              36.73              47.9
                    30.00              33.89              47.9
                    0.45               33.74              47.9
                    6.78               33.52              47.9
                    11.57              36.97              47.9
    L2              16.72              36.43              47.9
                    19.58              37.58              47.9
                    26.91              38.93              47.9
                    30.00              34.69              47.9

Notes :      1.L1: One end & Ground L2: The other end & Ground
             2.Height of table on which the EUT was placed : 0.8 m.
             3.The above test results are obtained under the normal
               condition.



Report Number: MLT9912P15003                     FCC ID: FI7R8ER00


                        MAX LIGHT
                      MEASUREMENT REPORT                      Page: 13/20
     Technology Lab

III. Radiated Emissions Requirements
3.1 General & Setup :
      Prior to open-field testing, the EUT was placed in a shielded
enclosure and scanned at a close distance to determine its emission
characteristics. The physical arrangement of the EUT was varied (within
the scope of arrangements likely to be encountered in actual use) to
determine the effect on the unit's emanations in amplitude, directivity, and
frequency. The exact system configuration which produced the highest
emissions was noted so it could be reproduced later during the open-field
tests. This was done to ensure that the final measurements would
demonstrate the worst-case interference potential of the EUT. Final
radiation measurements were made on a three-meter, open-field test site.
The EUT system was placed on a nonconductive turntable which is 0.8
meters height, top surface 1.0 x 1.5 meter. The spectrum was examined
from 30 MHz to 1000 MHz using an Hewlett Packard 8591EM Spectrum
Analyzer, EMCO Biconical Antenna (Model 3142) for 30-1000MHz. At each
frequency, the EUT was rotated 360 degrees, and the antenna was raised
and lowered from one to four meters to find the maximum emission levels.
Measurements were taken using both horizontal and vertical antenna
polarization. Appropriate preamplifiers were used for improving sensitivity
and precautions were taken to avoid overloading or desensitizing the
spectrum analyzer. No post-detector video filters were used in the test.
The spectrum analyzer's 6 dB bandwidth was set to 120 KHz, and the
analyzer was operated in the quasi-peak detection mode. The highest
emission amplitudes relative to the appropriate limit were measured and
recorded in paragraph 3.6.



3.2 Test Equipment List:

A.   HP 8591EM 9KHz-1.8GHz Spectrum Analyzer (S/N:73412A00230)
B.   HP 8447D Pre Amplifier (S/N:2944A08954)
C.   EMCO 3142 Biconilog Antenna (S/N:1184)
D.   HP 8590A 10KHz-1.5GHz Spectrum Analyzer (S/N:5212A000211)



Report Number: MLT9912P15003                     FCC ID: FI7R8ER00


                     MAX LIGHT
                    MEASUREMENT REPORT               Page: 14/20
  Technology Lab

3.3 Test Configuration:




              Front View of The Test Configuration




Report Number: MLT9912P15003             FCC ID: FI7R8ER00


                     MAX LIGHT
                    MEASUREMENT REPORT              Page: 15/20
  Technology Lab




              Rear View of The Test Configuration




Report Number: MLT9912P15003            FCC ID: FI7R8ER00


                        MAX LIGHT
                        MEASUREMENT REPORT               Page: 16/20
  Technology Lab



3.4 Test condition:

 EUT tested in accordance with the specifications given by the
manufacturer , and exercised in the most unfavorable manner.




3.5 Radiated Emissions Limits:


   Frequency range (MHz)                  Peak(dBuV)
            30 to 88                            40
           88 to 216                           43.5
           216 to 960                           46
           Above 960                            54




Report Number: MLT9912P15003                 FCC ID: FI7R8ER00


                         MAX LIGHT
                        MEASUREMENT REPORT                   Page: 17/20
  Technology Lab


3.6 Measurement Data Of Radiated Emissions:

   3.6.1 Open Field Radiated Emissions (HORIZONTAL)

     The highest peak values of radiated emissions from the EUT at
various antenna heights, antenna polarization, EUT orientation , etc. are
recorded on the following


Applicant               : Archtek Telecom Corporation.
Model No                : SCR2000E
EUT                     : Smart Card Reader

              Radiated Emissions (HORIZONTAL)
 Frequency   Amplitude      Ant.     Table Limits(Class B)   Margin
   (MHz)     (dBuV/m)       (m)    (Degree)   (dBuV/m)        (dB)
   42.96        31.07        1       360          40         -8.93
   57.35        33.18       1.5      270          40         -6.82
   64.33        32.52        1       300          40         -7.48
   71.54        34.28        2       300          40         -5.72
   78.82        33.09        2       360          40         -6.91
   121.76       35.63       1.5      200         43.5        -7.87
   129.00       36.95       1.5      360         43.5        -6.55
   136.14       37.43        1       300         43.5        -6.07
   188.25       35.91        2       270         43.5        -7.59
   190.00       35.72        1       360         43.5        -7.78
   294.35       37.93       2.5      300          46         -8.07

Notes : 1.Margin= Amplitude - Limits
       2.Distance of Measurement : 3 Meter (30-1000MHz)
       3.Height of table for EUT placed: 0.8 Meter.
       4.ANT= Antenna height.
       5.Amplitude= Reading Amplitude –Amplifier gain+Cable loss
                     +Antenna factor
                (Auto calculate in spectrum analyzer)


Report Number: MLT9912P15003                      FCC ID: FI7R8ER00


                         MAX LIGHT
                        MEASUREMENT REPORT                   Page: 18/20
  Technology Lab



   3.6.2 Open Field Radiated Emissions (VERTICAL)

     The highest peak values of radiated emissions from the EUT at
various antenna heights, antenna polarization, EUT orientation , etc. are
recorded on the following.


Applicant               : Archtek Telecom Corporation..
Model No                : SCR2000E
EUT                     : Smart Card Reader


                Radiated Emissions (VERTICAL)
 Frequency   Amplitude      Ant.     Table Limits(Class B)   Margin
   (MHz)     (dBuV/m)       (m)    (Degree)   (dBuV/m)        (dB)
   42.96        33.97        1       300          40          -6.03
   57.35        36.89       1.5      360          40          -3.11
   64.33        36.89        1       270          40          -3.11
   71.54        37.53       1.5      300          40          -2.47
   78.82        36.11        1       360          40          -3.89
   121.76       37.33       1.5      200         43.5         -6.17
   129.00       37.41        1       300         43.5         -6.09
   136.14       39.76       1.5      360         43.5         -3.74
   188.25       37.18        1       300         43.5         -6.32
   190.00       33.45        1       360         43.5        -10.05
   294.35       37.43       1.5      200          46          -8.57

Notes : 1.Margin= Amplitude - Limits
       2.Distance of Measurement : 3 Meter (30-1000MHz)
       3.Height of table for EUT placed: 0.8 Meter.
       4.ANT= Antenna height.
       5.Amplitude= Reading Amplitude –Amplifier gain+Cable loss
                     +Antenna factor
                (Auto calculate in spectrum analyzer)



Report Number: MLT9912P15003                      FCC ID: FI7R8ER00


                          MAX LIGHT
                        MEASUREMENT REPORT                                Page: 19/20
   Technology Lab



 Appendix I- EUT Test SETUP




MEASUREMENT OF POWER LINE CONDUCTED RFI VOLTAGE




                      EUT                0.8M




             0.8M

                                                                   LISN


           Metal floor surfaced with 30mm of insulating material




 Report Number: MLT9912P15003                            FCC ID: FI7R8ER00


                     MAX LIGHT
                     MEASUREMENT REPORT                                Page: 20/20
  Technology Lab



Appendix I- EUT Test SETUP



          MEASUREMENT OF RADIATED EMISSION




                                                                             Antenna
                                                                             Tower
                                              4.0M


                                 3.0M
                                                                              Receiver
                                                                              Antenna


             EUT



              0.8M




                               Ground Plane


                                                     0000




                                                            RF Test
                                                            Receiver



Report Number: MLT9912P15003                     FCC ID: FI7R8ER00



Document Created: 2019-03-30 03:27:46
Document Modified: 2019-03-30 03:27:46

© 2024 FCC.report