Resend Test Report

FCC ID: FI7MRIF56

Test Report

Download: PDF
FCCID_12129

Product                : 56K Internal Modem
Manufacture            : Archtek Telecom Corporation
FCC ID                 : FI7MRIF56
Model                  : 5634BIF
Report No.             : MLT9808P15006
Test Date              : 09/20/1998




Test By
              Max Light Technology Co.,Ltd.
          Room 5, 8F, No.125, Section 3 Roosevelt Road,
                     Taipei, Taiwan., R.O.C.
          Tel: 886-2-2363-2447 Fax: 886-2-2363-2597


                         MAX LIGHT
                        MEASUREMENT REPORT         Page: 2
   Technology Lab


Table of Contents :
I. General                                                  4.

II. Conducted Emissions Requirements                        9.

III. Radiated Emissions Requirements                        14.

Appendix I (EUT Test Setup)                                 20.




Report Number: MLT9808P15006            FCC ID: FI7MRIF56


                        MAX LIGHT
                       MEASUREMENT REPORT                   Page: 3
   Technology Lab
                     CERTIFICATION

 We here by verify that :

      The test data, data evaluation, test procedures and equipment
 configurations shown in this report were made in accordance with the
 procedures given in ANSI C63.4-1992. All test were conducted by
 MLT(Max Light Technology Co.,Ltd) Room 5, 8F, No.125, Section 3
 Roosevelt Road, Taipei, Taiwan, R.O.C Also, we attest to the accuracy
 of each.
      We further submit that the energy emitted by the sample EUT
tested as described in the report is in compliance with Class B radiated
and conducted emission limit of FCC Rules Part 15 Subpart B.


 EUT                   : 56K Internal Modem

 Applicant             : Archtek Telecom Corporation .
                              4F. No.9, Lane 130, Min-Chyuan Rd.,
                              Hsin-Tien , Taipei ,Taiwan

 Manufacturer          : Archtek Telecom Corporation .
                              4F. No.9, Lane 130, Min-Chyuan Rd.,
                              Hsin-Tien , Taipei ,Taiwan

 Model No              : 5634BIF

 FCC ID                : FI7MRIF56




 Prepared by :        Country        Approved by :        Roger
                    Country Huang                       Roger Chen


 Report Number: MLT9808P15006                    FCC ID: FI7MRIF56


                       MAX LIGHT
                     MEASUREMENT REPORT                    Page: 4
  Technology Lab

I. GENERAL

1.1 Introduction
      The following measurement report is submitted on behalf of
Archtek Telecom Corporation. In support of a Class B Digital Device
certification in accordance with Part2 Subpart J and Part 15 Subpart A
And B of the Commission’s and Regulations.


1.2 Description of EUT

EUT                  : 56K Internal Modem

Applicant            : Archtek Telecom Corporation .
                           4F. No.9, Lane 130, Min-Chyuan Rd.,
                           Hsin-Tien , Taipei , Taiwan

Manufacturer         : Archtek Telecom Corporation .
                           4F. No.9, Lane 130, Min-Chyuan Rd.,
                           Hsin-Tien , Taipei , Taiwan

Model No             : 5634BIF

FCC ID               : FI7MRIF56

Power Type           : Powered by PC

Phone Cable          : RJ-11Cx2(Nonshielded, 7’ long ,Plastic hoods)




     During testing the EUT was operated at Tx or Rx mode for each
emission measured. This was done in order to ensure that maximum
emission levels were attained.


Report Number: MLT9808P15006                   FCC ID: FI7MRIF56


                           MAX LIGHT
                          MEASUREMENT REPORT             Page: 5
  Technology Lab

1.3 Description of Support Equipment
       In order to construct the minimum system which required by
the ANSI C63.4-1991, following equipments were used as the support
units.

Computer           :   COMPAQ
Model No.          :   3284
Serial No.         :   L708BKTB4154
FCC ID             :   EJH3284

Keyboard           :   COMPAQ
Model No.          :   KPQ-E99ZC-13
Serial No.         :   237743-334
FCC ID             :   CMYKPQ7285

Monitor            :   COMPAQ
Model No.          :   303U
Serial No.         :   704AG19TG099
FCC ID             :   BJMCM14UH

Mouse              :   COMPAQ
Model No.          :   285728-001
Serial No.         :   97033491
FCC ID             :   FSUGMZE4

Printer            :   PANASONIC
Model No.          :   KX-P1080I
Serial No.         :   7CKAKE98933
FCC ID             :   ACJ5Z6KX-P10801

PSTN Simulator : MLT
Model No.      : 1101
Serial No.     : N/A




Report Number: MLT9808P15006                  FCC ID: FI7MRIF56


                        MAX LIGHT
                       MEASUREMENT REPORT                   Page: 6
  Technology Lab



Telephone          : GE
Model No.          : 2-9240A
Serial No.         : 1943K

Speaker            : KAKA
Model No.          : 2K-A01
Serial No.         : 189665

Microphone         : Ever Power
Model No.          : TC-944
Serial No.         : N/A

Modem              : Askey (External Fax / Data Modem)
Model No.          : WS1414SV
Serial No.         : IAH-10811




Report Number: MLT9808P15006                     FCC ID: FI7MRIF56


                          MAX LIGHT
                         MEASUREMENT REPORT                           Page: 7
  Technology Lab

1.4 Configuration of System Under Test




                                   Power Supply

                         RS-232                   RS-232
                                                                 RJ11C Cables


                                                                      PSTN
               Printer
                                        Monitor
                                                               Telephone
                                  PC

  EUT
                                       Keyboard


                         Mouse



During testing the EUT(Data/Fax Modem card) install in the Compaq PC.
So there is no need for additional I/O card. A mouse was connected to
the mouse port and a printer was connected to the parallel port. There is
one serial port. A external modem connected the serial port and the
external modem connected with two unterminated telephone cables on
the line and phone jack. A telephone set was connected to the Phone
Jack of EUT and the Line Jack of EUT was connected to a simulator of
PSTN.




Report Number: MLT9808P15006                               FCC ID: FI7MRIF56


                       MAX LIGHT
                      MEASUREMENT REPORT                   Page: 8
  Technology Lab

1.5 Test Procedure
     All measurements contained in this report were performed
according to the techniques described in Measurement procedure ANSI
C63.4-1992 "Measurement of unIntentional Radiators."


1.6 General Test Condition
      The conditions under which the EUT operates were varied to
determine their effect on the equipment's emission characteristics. The
final configuration of the test system and the mode of operation used
during these tests was chosen as that which produced the highest
emission levels. However, only those conditions which the EUT was
considered likely to encounter in normal use were investigated. The
system's radiated and conducted emissions were investigated while the
computer alternately transferred data to the EUT as well as to the
monitor and printer. Using a test program which sent a continuous
stream of “H” characters to monitor and transferred data to and from
the EUT was proven to worst case emissions. The system's physical
layout and cabling was randomly arranged to ensure that maximum
emission levels were attained.




Report Number: MLT9808P15006                    FCC ID: FI7MRIF56


                       MAX LIGHT
                      MEASUREMENT REPORT                    Page: 9
     Technology Lab

II. Conducted Emissions Requirements

2.1 General & Setup :

     The power line conducted emission measurements were performed
in a shielded enclosure. The EUT was assembled on a wooden table
which is 80 centimeters high, was placed 40 centimeters from the
backwall and at least 1 meter from the sidewall.

     Power was fed to the EUT from the public utility power grid through
a line filter and EMCO Model 3825/2 Line Impedance Stabilization
Networks (LISN). The LISN housing, measuring instrumentation case,
ground plane, etc., were electrically bonded together at the same RF
potential. The Spectrum analyzer was connected to the AC line through
an isolation transformer. The 50-ohm output of the LISN was connected
to the spectrum analyzer directly. Conducted emission levels were in
the CISPER quasi-peak detection mode. The analyzer's 6 dB bandwidth
was set to 9 KHz. No post-detector video filter was used.

     The spectrum was scanned from 450 KHz to 30 MHz. The physical
arrangement of the test system and associated cabling was varied
(within the scope of arrangements likely to be encountered in actual
use) to determine the effect on the unit's emanations in amplitude and
frequency. All spurious emission frequencies were observed. The
highest emission amplitudes relative to the appropriate limit were
measured and have been recorded in paragraph 2.6.




2.2 Test Equipment List:

A.   EMCO 3825/2 LISN (S/N:2654)
B.   EMCO 3825/2 LISN (S/N:2658)
C.   HP 8591EM 9KHZ-1.8GHz Spectrum Analyzer (S/N:73412A00110)
D.   Shielded Room (MLT-SR1)


Report Number: MLT9808P15006                    FCC ID: FI7MRIF56


                     MAX LIGHT
                    MEASUREMENT REPORT              Page: 10
  Technology Lab

2.3 Test Configuration:




             Front View of The Test Configuration




Report Number: MLT9808P15006             FCC ID: FI7MRIF56


                     MAX LIGHT
                    MEASUREMENT REPORT              Page: 11
  Technology Lab




             Rear View of The Test Configuration




Report Number: MLT9808P15006             FCC ID: FI7MRIF56


                      MAX LIGHT
                      MEASUREMENT REPORT                 Page: 12
  Technology Lab

2.4 Test condition:

 EUT tested in accordance with the specifications given by the
manufacturer , and exercised in the most unfavorable manner.



2.5 Conducted Emissions Limits:


Frequency range (MHz)                 Limits (dBuV)
       0.45 to 30                           47.9




Report Number: MLT9808P15006                 FCC ID: FI7MRIF56


                        MAX LIGHT
                       MEASUREMENT REPORT                   Page: 13
  Technology Lab

2.6 Measurement Data Of Conducted Emissions:

  The following table show a summary of the highest emissions of
power line conducted emissions to the HOT and NATURAL conductor of
the EUT power.


Manufacturer          : Archtek Telecom Corporation.
Model No              : 5634BIF
EUT                   : 56K Internal Modem

          Power Line Conducted Emissions (Class B)
Conductor       Frequency       Peak Amplitude          Limits
                  (MHz)             (dBuV)              (dBuV)
                    0.45             33.44                47.9
                    6.75             31.56                47.9
                    8.42             35.41                47.9
    L1             11.31             37.65                47.9
                   13.53             39.55                47.9
                   16.54             36.78                47.9
                   30.00             37.01                47.9
                    0.45             32.15                47.9
                    6.75             31.78                47.9
                    8.42             36.55                47.9
    L2             11.31             37.73                47.9
                   13.53             38.39                47.9
                   16.54             37.43                47.9
                   30.00             36.51                47.9

Notes :     1.L1: One end & Ground L2: The other end & Ground
            2.Height of table on which the EUT was placed : 0.8 m.
            3.The above test results are obtained under the normal
              condition.



Report Number: MLT9808P15006                     FCC ID: FI7MRIF56


                        MAX LIGHT
                      MEASUREMENT REPORT                     Page: 14
     Technology Lab

III. Radiated Emissions Requirements
3.1 General & Setup :
      Prior to open-field testing, the EUT was placed in a shielded
enclosure and scanned at a close distance to determine its emission
characteristics. The physical arrangement of the EUT was varied
(within the scope of arrangements likely to be encountered in actual
use) to determine the effect on the unit's emanations in amplitude,
directivity, and frequency.     The exact system configuration which
produced the highest emissions was noted so it could be reproduced
later during the open-field tests. This was done to ensure that the final
measurements would demonstrate the worst-case interference
potential of the EUT. Final radiation measurements were made on a
three-meter, open-field test site. The EUT system was placed on a
nonconductive turntable which is 0.8 meters height, top surface 1.0 x
1.5 meter. The spectrum was examined from 30 MHz to 1000 MHz using
an Hewlett Packard 8591EM Spectrum Analyzer, EMCO Biconical
Antenna (Model 3142) for 30-1000MHz. At each frequency, the EUT was
rotated 360 degrees, and the antenna was raised and lowered from one
to four meters to find the maximum emission levels. Measurements
were taken using both horizontal and vertical antenna polarization.
Appropriate preamplifiers were used for improving sensitivity and
precautions were taken to avoid overloading or desensitizing the
spectrum analyzer. No post-detector video filters were used in the test.
The spectrum analyzer's 6 dB bandwidth was set to 120 KHz, and the
analyzer was operated in the quasi-peak detection mode. The highest
emission amplitudes relative to the appropriate limit were measured
and recorded in paragraph 3.6.

3.2 Test Equipment List:

A.   HP 8591EM 9KHz-1.8GHz Spectrum Analyzer (S/N:73412A00230)
B.   HP 8447D Pre Amplifier (S/N:2944A08954)
C.   EMCO 3142 Biconilog Antenna (S/N:1184)
D.   HP 8590A 10KHz-1.5GHz Spectrum Analyzer (S/N:5212A000211)
Report Number: MLT9808P15006                     FCC ID: FI7MRIF56


                     MAX LIGHT
                    MEASUREMENT REPORT              Page: 15
  Technology Lab

3.3 Test Configuration:




             Front View of The Test Configuration




Report Number: MLT9808P15006             FCC ID: FI7MRIF56


                     MAX LIGHT
                    MEASUREMENT REPORT              Page: 16
  Technology Lab




             Rear View of The Test Configuration




Report Number: MLT9808P15006             FCC ID: FI7MRIF56


                         MAX LIGHT
                         MEASUREMENT REPORT              Page: 17
  Technology Lab

3.4 Test condition:

 EUT tested in accordance with the specifications given by the
manufacturer , and exercised in the most unfavorable manner.




3.5 Radiated Emissions Limits:


   Frequency range (MHz)                  Peak(dBuV)
             30 to 88                           40
            88 to 216                          43.5
            216 to 960                          46
            Above 960                           54




Report Number: MLT9808P15006                 FCC ID: FI7MRIF56


                           MAX LIGHT
                         MEASUREMENT REPORT                   Page: 18
  Technology Lab

3.6 Measurement Data Of Radiated Emissions:

   3.6.1 Open Field Radiated Emissions (HORIZONTAL)

     The highest peak values of radiated emissions from the EUT at
various antenna heights, antenna polarization, EUT orientation , etc. are
recorded on the following


Manufacturer             : Archtek Telecom Corporation
Model No                 : 5634BIF
EUT                      : 56K Internal Modem

               Radiated Emissions (HORIZONTAL)
 Frequency     Amplitude     Ant.     Table Limits(Class B)   Margin
   (MHz)       (dBuV/m)      (m)    (Degree)   (dBuV/m)        (dB)
    80.65        34.16       1.5      300          40         -5.84
   112.91        36.58       1.5      360         43.5        -6.92
   132.86        37.83        1       300         43.5        -5.67
   166.03        39.98        1       270         43.5        -3.52
   199.23        37.56       1.5       0          43.5        -5.94
   226.13        40.12        2       300          46         -5.88
   282.26        37.89       1.5      270          46         -8.11
   310.40        36.47        1       300          46         -9.53
   366.95        39.56       2.5      270          46         -6.44
   395.16        36.87        2       360          46         -9.13
   412.34        38.79        2       300          46         -7.21

Notes : 1.Margin= Amplitude - Limits
       2.Distance of Measurement : 3 Meter (30-1000MHz)
       3.Height of table for EUT placed: 0.8 Meter.
       4.ANT= Antenna height.
       5.Amplitude= Reading Amplitude –Amplifier gain+Cable loss
                     +Antenna factor
                (Auto calculate in spectrum analyzer)



Report Number: MLT9808P15006                       FCC ID: FI7MRIF56


                           MAX LIGHT
                         MEASUREMENT REPORT                   Page: 19
  Technology Lab


   3.6.2 Open Field Radiated Emissions (VERTICAL)

     The highest peak values of radiated emissions from the EUT at
various antenna heights, antenna polarization, EUT orientation , etc. are
recorded on the following.


Manufacturer             : Archtek Telecom Corporation.
Model No                 : 5634BIF
EUT                      : 56K Internal Modem


                 Radiated Emissions (VERTICAL)
 Frequency     Amplitude     Ant.     Table Limits(Class B)   Margin
   (MHz)       (dBuV/m)      (m)    (Degree)   (dBuV/m)        (dB)
    80.65        35.66        1       360          40         -4.34
   112.91        37.16       1.5      300         43.5        -6.34
   132.86        36.89       1.5       0          43.5        -6.61
   166.03        39.99        1       360         43.5        -3.51
   199.23        37.54        1       200         43.5        -5.96
   226.13        42.13       1.5      300          46         -3.87
   282.26        37.72       1.5      270          46         -8.28
   310.40        37.41        2       300          46         -8.59
   366.95        38.74        1       360          46         -7.26
   395.16        38.99        2       300          46         -7.01
   412.34        38.42        1        0           46         -7.58

Notes : 1.Margin= Amplitude - Limits
       2.Distance of Measurement : 3 Meter (30-1000MHz)
       3.Height of table for EUT placed: 0.8 Meter.
       4.ANT= Antenna height.
       5.Amplitude= Reading Amplitude –Amplifier gain+Cable loss
                     +Antenna factor
                (Auto calculate in spectrum analyzer)




Report Number: MLT9808P15006                       FCC ID: FI7MRIF56


                          MAX LIGHT
                        MEASUREMENT REPORT                                Page: 20
   Technology Lab

 Appendix I- EUT Test SETUP




MEASUREMENT OF POWER LINE CONDUCTED RFI VOLTAGE




                      EUT                0.8M




             0.8M

                                                                   LISN


           Metal floor surfaced with 30mm of insulating material




 Report Number: MLT9808P15006                             FCC ID: FI7MRIF56


                     MAX LIGHT
                     MEASUREMENT REPORT                                 Page: 21
  Technology Lab

Appendix I- EUT Test SETUP



          MEASUREMENT OF RADIATED EMISSION




                                                                              Antenna
                                                                              Tower
                                              4.0M


                                 3.0M
                                                                               Receiver
                                                                               Antenna


             EUT



              0.8M




                               Ground Plane


                                                      0000




                                                             RF Test
                                                             Receiver



Report Number: MLT9808P15006                         FCC ID: FI7MRIF56



Document Created: 2019-11-14 05:03:48
Document Modified: 2019-11-14 05:03:48

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC