                                                                                             Test report No. 1707604STO-003, Ed. 2
                                                                                                                                          Page 1 (4)




           STATEMENT ON EXPOSURE TO
            ELECTROMAGNETIC FIELDS
     EQUIPMENT

     Type of equipment:                                                 Zigbee radio module

     Type / Model:                                                      ICC-A-1
     Manufacturer:                                                      IKEA of Sweden AB

     By request of:                                                     IKEA of Sweden AB



     STANDARD

     EN 62479
     47 CFR §1.1310
     RSS-102 Issue 5
     Radiation Protection Standard for Maximum Exposure Levels to Radiofrequency fields – 3
     kHz to 300 GHz
     AS/NZS 2772.1


     CONDITIONS

     Operating frequency range is 2405-2480 MHz.

     Highest output power to antenna is +12.60 dBm.

     Antenna gain is -3.6 dBi.

     A test separation distance of 5 mm is used for handheld/portable applications.

     A test separation distance of 20 cm is used for mobile applications.

     Maximum (worst case) duty cycle is 22.4%


This Statement of Compliance is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's
responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance
with the agreement, for any loss, expense or damage occasioned by the use of this Statement. Only the Client is authorized to permit copying or distribution of
this Statement of Compliance. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be
approved in writing by Intertek.


                                                                                             Test report No. 1707604STO-003, Ed. 2
                                                                                                                                          Page 2 (4)

     CALCULATIONS

     EIRP:



     Conversion dBm to W:

                                                                           (ଵଶ.଺଴ௗ஻௠ /ଵ଴)
     Conducted:

                                                                           (ଽ.଴ௗ஻௠ /ଵ଴)
     EIRP:


     Time averaged maximum power:

     Conducted:

     EIRP:


     Power density S:

                                                                       ୛          ୈେ×୉୍ୖ୔          ଴.ଶଶସ×଴.଴଴଻ଽ
     5 mm separation distance:
                                                                      ௠మ           ସ×஠×ோమ             ସ×஠×଴.଴଴ହమ

                                                                       ୛          ୈେ×୉୍ୖ୔          ଴.ଶଶସ×଴.଴଴଻ଽ
     20 cm separation distance:
                                                                      ௠మ           ସ×஠×ோమ             ସ×஠×଴.ଶ଴మ




This Statement of Compliance is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's
responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance
with the agreement, for any loss, expense or damage occasioned by the use of this Statement. Only the Client is authorized to permit copying or distribution of
this Statement of Compliance. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be
approved in writing by Intertek.


                                                                                             Test report No. 1707604STO-003, Ed. 2
                                                                                                                                          Page 3 (4)

     LIMITS & EVALUATIONS:


                     Standard                                   Reference for limit                            Limit          Unit        Values          Result


                   EN 62479                                          EN 624791                                   40           mW             2.0          PASS


                                                               KDB 447498 D012                                  7.5            NA           0.64          PASS
             CFR 47 §1.1310
                                                                CFR 47 §1.13103                                  10          W/m2          0.004          PASS


                                                         RSS-102 issue 5 (2015)4                                 10           mW             5.0          PASS
             RSS-102 issue 5
                 (2015)
                                                         RSS-102 issue 5 (2015)5                               2700           mW             2.0          PASS


        Radiation Protection
                               Radiation Protection Standard
       Standard for Maximum
                               for Maximum Exposure Levels
        Exposure Levels to                                                                                       10          W/m2           5.71          PASS
                                to Radiofrequency fields – 3
       Radiofrequency fields –
                                     kHz to 300 GHz6
         3 kHz to 300 GHz


              AS/NZS 2772.1                                     AS/NZS 2772.27                                   20           mW             2.0          PASS


           1. Table A.1: For general public and limbs exposure.

           2. Section 4.3.1, 1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test
              separation distances ≤ 50 mm are determined by:

                  [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·
                 [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR

                 The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for
                 transmission frequencies between 100 MHz and 6 GHz

           3. (e) Table 1 – Limits for maximum permissible exposure. For frequency range 1500 – 100 000 MHz and
              general population/uncontrolled exposure the maximum allowed power density is 1 mW/cm 2 = 10 W/m2

           4. Section 2.5.2: at or above 300 MHz and below 6 GHz and the source-based, time-averaged maximum
              e.i.r.p. of the device is equal to or less than 1.31 x 10-2 ƒ0.6834 W (adjusted for tune-up tolerance), where
              ƒ is in MHz


This Statement of Compliance is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's
responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance
with the agreement, for any loss, expense or damage occasioned by the use of this Statement. Only the Client is authorized to permit copying or distribution of
this Statement of Compliance. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be
approved in writing by Intertek.


                                                                                             Test report No. 1707604STO-003, Ed. 2
                                                                                                                                          Page 4 (4)

           5. Section 2.5.1, Table 1: 4 mW at 2450 MHz. For limb-worn devices where the 10 gram value applies,
              the exemption limits for routine evaluation in Table 1 are multiplied by a factor of 2.5

           6. Table 7: For general public and 2 GHz- 300 GHz the equivalent plane wave power flux density is: 10

           7. Section 3.7.3: In some circumstances an RF exposure evaluation may not be required. This is the case
              with low-power devices whose nominal average RF radiated power does not exceed 20 mW and which
              do not produce exceptionally high instantaneous fields.



     Intertek Semko AB, Radio & EMC

     Date of issue: 2017-06-14




     Issued by: Daniel Nilsson




This Statement of Compliance is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's
responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance
with the agreement, for any loss, expense or damage occasioned by the use of this Statement. Only the Client is authorized to permit copying or distribution of
this Statement of Compliance. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be
approved in writing by Intertek.



Document Created: 2017-06-14 09:30:52
Document Modified: 2017-06-14 09:30:52

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC