MPE

FCC ID: FDI-09101561

RF Exposure Info

Download: PDF
FCCID_1208136

                                                Report No.: FR9O1315




             Appendix C. Maximum Permissible Exposure




FCC ID: FDI-09101561                           Page No.   : C1 of C3


                                                                                                    Report No.: FR9O1315



1. Maximum Permissible Exposure
1.1. Applicable Standard

      Systems operating under the provisions of this section shall be operated in a manner that ensures that the
      public is not exposed to radio frequency energy levels in excess limit for maximum permissible exposure.
      In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as a mobile
      device whereby a distance of 0.2 m normally can be maintained between the user and the device.
      (A) Limits for Occupational / Controlled Exposure
                                                                                                         Averaging Time
        Frequency Range                Electric Field     Magnetic Field         Power Density (S)
                                                                                                          |E|²,|H|² or S
              (MHz)                 Strength (E) (V/m)   Strength (H) (A/m)         (mW/ cm²)
                                                                                                            (minutes)
              0.3-3.0                      614                 1.63                    (100)*                   6
               3.0-30                    1842 / f             4.89 / f                (900 / f)*                6
              30-300                      61.4                 0.163                     1.0                    6
             300-1500                                                                   F/300                   6
          1500-100,000                                                                      5                   6
      (B) Limits for General Population / Uncontrolled Exposure
                                                                                                         Averaging Time
        Frequency Range                Electric Field     Magnetic Field        Power Density (S)
                                                                                                          |E|²,|H|² or S
              (MHz)                 Strength (E) (V/m)   Strength (H) (A/m)        (mW/ cm²)
                                                                                                            (minutes)
             0.3-1.34                     614                  1.63                    (100)*                  30
              1.34-30                     824/f                2.19/f                  (180/f)*                30
              30-300                      27.5                 0.073                     0.2                   30
             300-1500                                                                  F/1500                  30
          1500-100,000                                                                   1.0                   30
      Note: f = frequency in MHz ; *Plane-wave equivalent power density

1.2. MPE Calculation Method

      E (V/m) =
                       30 × P × G                   Power Density:      Pd (W/m²) =
                                                                                      E2
                           d                                                          377
      E = Electric field (V/m)
      P = Peak RF output power (W)
      G = EUT Antenna numeric gain (numeric)
      d = Separation distance between radiator and human body (m)
      The formula can be changed to

      Pd =
              30 × P × G
               377 × d 2
      From the peak EUT RF output power, the minimum mobile separation distance, d=0.2m, as well as the gain
      of the used antenna, the RF power density can be obtained.



FCC ID: FDI-09101561                                                                               Page No.   : C2 of C3


                                                                                        Report No.: FR9O1315


1.3. Calculated Result and Limit

      For 2.4GHz Band
      Antenna Type : Printed Antenna
      Max Conducted Power for 802.11g Ant. 1+ Ant. 2: 19.73 dBm
                                       Peak Output                  Power Density Limit of Power
       Antenna Gain Antenna Gain                     Peak Output
                                          Power                          (S)        Density (S)    Test Result
           (dBi)      (numeric)                      Power ( mW )
                                          (dBm)                       (mW/cm²)      (mW/cm²)
            1.37        1.3709          19.7253        93.8709        0.025614          1          Complies




FCC ID: FDI-09101561                                                                   Page No.    : C3 of C3



Document Created: 2009-12-03 11:24:06
Document Modified: 2009-12-03 11:24:06

© 2024 FCC.report