Installation guide 1

FCC ID: EWQ100WD

Users Manual

Download: PDF
FCCID_1841316

Water Solutions
100W-R/100W-R+ and 100WP-R/100WP-R+
Datalogging ERT Module Installation Guide
TDC-0951-006


Identification
100W-R/100W-R+ and 100WP-R/100WP-R+ Datalogging ERT Module Installation Guide
08 November 2012 TDC-0951-006
100W-R/100W-R+ and 100WP-R/100WP-R+ ERT module
Copyright
© 2012 Itron, Inc. All rights reserved.

Confidentiality Notice
The information contained herein is proprietary and confidential and provided subject to the condition that (i) it is held in confidence except to the extent required otherwise by law and (ii) it is
used only for the purposes described herein. Any third party given access to this information is similarly bound in writing.
Compliance Statement
This device complies with Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Operation is subject to
the following two conditions:
    • This device may not cause harmful interference.
    • This device must accept any interference that may cause undesirable operation.
This device must be permanently mounted such that it retains a distance of 20 centimeters (7.9 inches) from all persons in order to comply with FCC RF exposure levels.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
        • Reorient or relocate the receiving antenna.
        • Increase the separation between the equipment and receiver.
        • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
        • Consult the dealer or an experienced radio or TV technician for help.
   Compliance Statement                                                                        Déclaration de conformité
   This equipment complies with policies RSS-210 and RSS-GEN of the Industry Canada Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de
   rules.                                                                                      licence. L'exploitation est autorisée aux deux conditions suivantes :
   Operation is subject to the following two conditions:                                              • (1) l'appareil ne doit pas produire de brouillage, et
          • (1) this device may not cause interference, and                                           • (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage
          • (2) this device must accept any interference, including interference that may                  est susceptible d'en compromettre le fonctionnement.
                cause undesired operation of the device.
   Compliance Statement Canada                                                                 Déclaration de Conformité
   Under Industry Canada regulations, this radio transmitter may only operate using an         Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une
   antenna of a type and maximum (or lesser) gain approved for the transmitter by              antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le
   Industry Canada. To reduce potential radio interference to other users, the antenna         but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type
   type and its gain should be so chosen that the equivalent isotropically radiated power      d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas
   (e.i.r.p.) is not more than that necessary for successful communication.                    l'intensité nécessaire à l'établissement d'une communication satisfaisante.
Trademark Notice
Itron is a registered trademark of Itron, Inc.
All other product names and logos in this documentation are used for identification purposes only and may be trademarks or registered trademarks of their respective companies.

                    Warning To prevent ignition of flammable or combustible atmospheres, disconnect power before
                    servicing.

                    Warning Follow these procedures to avoid injury to yourself or others:
                          •    The lithium battery may cause a fire or chemical burn if it is not disposed of properly.
                               Do not recharge, disassemble, heat above 100° Celsius (212° Fahrenheit), crush, expose to water, or incinerate the lithium battery.
                          •    Fire, explosion, and severe burn hazard.
                          •    Keep the lithium battery away from children.

                    Warning ELECTROMAGNETIC COMPATIBILITY
                    Use only approved accessories with this equipment. Unapproved modifications or operation beyond or
                    in conflict with these instructions for use may void authorization by the authorities to operate the
                    equipment.

                    Warning This unit cannot be modified and is not repairable. Attempts to modify or repair this device will
                    void the warranty.




TDC-0951-006 100W-R/100W-R+ and 100WP-R/100WP-R+ Datalogging ERT Module Installation Guide                                                                                                      ii
                                     Proprietary and Confidential


Transportation Classification
The Federal Aviation Administration prohibits operating transmitters and receivers on all commercial aircraft. When powered, ERT modules are considered operating transmitters and receivers
and cannot be shipped by air. All product returns must be shipped by ground transportation to Itron.
Suggestions
If you have comments or suggestions on how we may improve this documentation, send them to TechnicalCommunicationsManager@itron.com
If you have questions or comments about the software or hardware product, contact Itron Technical Support:
Contact
      • Internet: www.itron.com
      • E-mail: support@itron.com
      • Phone: 800 635 8725




TDC-0951-006 100W-R/100W-R+ and 100WP-R/100WP-R+ Datalogging ERT Module Installation Guide                                                                                        iii
                                     Proprietary and Confidential


TDC-0951-006 100W-R/100W-R+ and 100WP-R/100WP-R+ Datalogging ERT Module Installation Guide   iv
                                     Proprietary and Confidential


Contents


Chapter 1 Before You Begin ........................................................................................ 1
       Document Conventions ....................................................................................................................... 1
       Document Purpose .............................................................................................................................. 1
       How This Document is Organized ....................................................................................................... 1
       Related Documents ............................................................................................................................. 2


Chapter 2 About the 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT Modules ..... 3
       100W-R/100W-R+ and 100WP-R/100WP-R+ Models ........................................................................ 4
       Itron Security Manager ........................................................................................................................ 5
              Enabling 100W-R+ and 100WP-R+ Security ............................................................................ 5
       Battery Life .......................................................................................................................................... 5
       100W-R/100W-R+ and 100WP-R/100WP-R+ ERT Module Transmission Modes .............................6
       100W-R/100W-R+ Operating Modes .................................................................................................. 6
       100WP-R/100WP-R+ Operating Modes ............................................................................................. 7
       100W-R/100W-R+ and 100WP-R/100WP-R+ ERT Module Geo Mode .............................................8


Chapter 3 Initializing, Programming, and Connecting the ERT Module .................. 9
       Initializing the 100W-R/100W-R+ ........................................................................................................ 9
       100W-R/100W-R+ Encoder Start-up................................................................................................... 9
       Programming the 100WP-R/100WP-R+ ...........................................................................................10
       100WP-R/100WP-R+ Pulser Start-up ...............................................................................................10
       Connecting the 100W-R/100W-R+ to a Remote Meter Register ......................................................10
       Connecting the 100WP-R/100WP-R+ to a Remote Meter Register .................................................11
       Verifying 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT Module Operation .............................12


Chapter 4 Installing the 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT Module 13
       100W-R/100W-R+ and 100WP-R/100WP-R+ ERT Module Accessories .........................................13
       Installing 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT Module Cable Strain Relief ...............14
       Required Materials ............................................................................................................................14
       Attaching the Backplate.....................................................................................................................16
       Pipe Mount Installation ......................................................................................................................19
               Optional Leak Sensor Installation ...........................................................................................22
                     Connecting the Leak Sensor to the 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT
                     module ..........................................................................................................................23
                     Required Equipment .....................................................................................................24
                     Pipe Preparation ...........................................................................................................24
       Remote Mount Installation.................................................................................................................27
               Required Equipment ...............................................................................................................28
       Direct-Mounting to the Meter Register ..............................................................................................30




TDC-0951-006 100W-R/100W-R+ and 100WP-R/100WP-R+ Datalogging ERT Module Installation Guide                                                                    v
                                                              Proprietary and Confidential


Contents

Appendix A Using Gel-cap Connectors .................................................................... 37

Appendix B Troubleshooting .................................................................................... 39

Index ............................................................................................................................. 40




TDC-0951-006 100W-R/100W-R+ and 100WP-R/100WP-R+ Datalogging ERT Module Installation Guide                                          vi
                                                     Proprietary and Confidential


CHAPTER 1

Before You Begin

Document Conventions
Convention                                       Example
Itron product part numbers are noted in          To install the ERT module (ERW-1300-3XX), do the following steps.
parentheses.
Hypertext links are in blue.                     For more information about this document's structure, see How This Document is
                                                 Organized on page 1.

           Note A Note indicates neutral or positive information that stresses or supplements important points
           of the main text. A note supplies information that may apply only in special cases.

           Caution A Caution advises users that failure to take or avoid a specified action could result in a
           loss of data.

           Warning A Warning advises users that failure to take or avoid a specified action could result in
           physical harm to the user or the hardware.

Document Purpose
This document provides installation instructions for the 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT
modules including step-by-step instructions for pipe mount, remote mount, and direct mount.

           Caution Installing a remote ERT module or an integrated 100W/100W+ ERT module and meter
           register in a water pit box will void the product warranty. Remote ERTs are designed for interior
           and exterior (on the side of buildings) installations only. Use a pit ERT module for pit-mount
           applications. (Refer to the Water ERT Module Ordering Guide PUB-0063-001).


How This Document is Organized
This installation guide is organized with the following chapters:
Chapter                                        Description
1. Before You Begin                            Information about this publication
2. About the 100W-R/100W-R+ and 100WP-         Overview of 100W-R/100W-R+ and 100WP-R/100WP-R+ functionality.
R/100WP-R+
3. Initializing, Connecting, and Programming   Instructions to initialize the 100W-R/100W-R+ ERT module, program the
the ERT Module                                 100WP/100WP+ ERT module, and connect the ERT module to the register.
4. Installing the 100W-R/100W-R+ and           Step-by-step ERT module installation instructions for:
100WP-R/100WP-R+                                • Pipe mount
                                                      • Optional Leak Sensor
                                                • Remote mount
                                                • Direct mount
Appendix A Using Gel cap Connectors            Instructions for using gel cap connectors to connect the remote ERT module to the
                                               register.
Appendix B Troubleshooting                     Tips for troubleshooting 100W/100W+ ERT module operation.

TDC-0951-006 100W-R/100W-R+ and 100WP-R/100WP-R+ Datalogging ERT Module Installation Guide                                   1
                                                 Proprietary and Confidential


Before You Begin




Related Documents
Document Description                                                                Itron Part Number
100 Series Modules and CENTRON Bridge Meter Tamper Reference Guide                  TDC-1028-XXX
100W/100W+ and 100WP/100WP+ Datalogging ERT Module Installation Guide               TDC-0909-XXX
Field Deployment Manager Endpoint Tools Mobile Application Guide                    TDC-0934-XXX
Field Deployment Manager Field Representative's Guide                               TDC-0936-XXX
900 MHz Belt-Clip Radio User's Guide                                                TDC-0889-XXX
FC300 Getting Started Guide                                                         TDC-0898-XXX
FC200 Series Getting Started Guide                                                  TDC-0598-XXX
Water ERT Module Ordering Guide                                                     PUB-0063-001
Water Meter Compatibility List                                                      PUB-0063-002
mlogonline™ Network Leak Monitoring System User Guide                               TDC-0792-XXX

          Note XXX designates the document revision and is subject to change without notice.




TDC-0951-006 100W-R/100W-R+ and 100WP-R/100WP-R+ Datalogging ERT Module Installation Guide              2
                                                Proprietary and Confidential


CHAPTER 2

About the 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT
Modules

The 100W-R/100W-R+ and 100WP-R/100WP-R+ are high-power radio frequency automatic meter reading
(AMR) devices that attach to water registers to collect consumption usage and tamper data that the ERT
module transmits to a data collection device. The ERT module operates in both bubble-up mode and two-way
modes.
The 100W-R/100W-R+ and 100WP-R/100WP-R+ ship in factory mode. The ERT modules acquire and
transmit meter register data within one hour following register connection. The ERT module transfers meter
data immediately if the unit is initialized with a handheld computer during installation (see Initializing,
Programming, and Connecting the ERT Module).

         Caution Failure to initialize the ERT module may delay the initial reading up to 1 hour. The 100WP-
         R module will default to a consumption value of 0 if the ERT module is not programmed with Itron's
         Field Deployment Manager (FDM).

The 100W-R/100W-R+ and 100WP-R/100WP-R+ support protocols for a variety of meter manufacturer's
registers. Refer to the Water Meter Compatibility List (PUB-0063-002), for the list of supported meters and
registers.
100W-R/100W-R+ and 100WP-R/100WP-R+s feature the following capabilities:
•   Leak Detection and Reverse Flow Detection. 100W series ERT modules feature robust features to
    provide Leak Detection and Reverse Flow Detection. For more information about Leak Detection and
    Reverse Flow Detection, see the Itron white paper Detecting Leaks and Reverse Flow with 100 Series
    ERT Modules.
             Note The 100WP-R/100WP-R+ ERT module will not report reverse flow. Incremental encoded
             registers do not provide a distinguishing signal while flowing in reverse.

•   Communication Error Indicators.
    • Last Good Read (LGR Flag). Indicates a communication error with the register.
       • 100W-R/100W-R+ encoder ERT module
          If this flag is set for 24 consecutive hours, it initiates a cut cable flag in the extended tampers.
          The last good read flag automatically clears after the ERT module receives a successful read from
          the register.
       • 100WP-R/100WP-R+ pulser ERT module
          If the last good read flag is set two consecutive times, it initiates a cut cable flag in the extended
          tampers.
          The last good read flag automatically clears after the ERT module receives a successful read from
          the register.
                     Note A last good read flag may be an indicator of a damaged register.

•   Extended Tamper Flag. (Retrievable with two-way communication).
    • Low Battery Warning. The 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT modules include a
       battery life estimator. The estimator is based on the number of data packets sent at the various power
       levels and the age (self-discharge) of the ERT module. The low battery warning allows the utility to
TDC-0951-006 100W-R/100W-R+ and 100WP-R/100WP-R+ Datalogging ERT Module Installation Guide                3
                                           Proprietary and Confidential


About the 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT Modules



       easily identify which ERTs are nearing end-of-life in a mixed population and gives the opportunity to
       schedule replacement.
       The low battery warning is a single flag set when the battery has less than 10% remaining capacity,
       typically 2 years life remaining battery life is evaluated daily at midnight.
•   Cut Cable Flag.
    • 100W-R/100W-R+ encoder ERT module. The cut cable flag sets if the LGR Flag is active for 24
       hours.
    • 100WP-R/100WP-R+ pulser ERT module. The cut cable flag sets if the LGR Flag is active for two
       consecutive times.
    • The cut cable flag remains active for 40 days in mobile mode.
    • The cut cable flag remains active for 24 hours in fixed network mode.


100W-R/100W-R+ and 100WP-R/100WP-R+ Models
100W/100W+ Remote ERT Module Description                                       Itron Part Number
100W-R Encoder Remote, 10-inch flying lead                                     ERW-1300-213
100W-R+ Encoder Remote, 10-inch flying lead                                    ERW-1300-313
100W-R Encoder Remote with Leak Sensor, 10-inch flying lead                    ERW-1300-214
100W-R+ Encoder Remote with Leak Sensor, 10-inch flying lead                   ERW-1300-314
100WP-R Pulser Remote, 10-inch flying lead                                     ERW-1300-215
100WP-R+ Pulser Remote, 10-inch flying lead                                    ERW-1300-315
100WP-R Pulser Remote with Leak Sensor, 10-inch flying lead                    ERW-1300-216
100WP-R+ Pulser Remote with Leak Sensor, 10-inch flying lead                   ERW-1300-316




TDC-0951-006 100W-R/100W-R+ and 100WP-R/100WP-R+ Datalogging ERT Module Installation Guide             4
                                                Proprietary and Confidential


About the 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT Modules




Itron Security Manager (ISM)
The 100W-R+ and 100WP-R+ modules are components of a ChoiceConnect system. Itron system security
performed by Itron Security Managersupplies security to the RF communications between the handheld
computer, Mobile Collector, or Fixed Network system and the ERT module. There are two fundamental
security processes used in the ISM to ensure confidentiality and validity of the system communications.
•   Authentication. Authentication is the process of confirming that an artifact is genuine or valid.
    Authentication in the 100W-R+ and 100WP-R+ is the process of verifying a request is from a valid source
    and in its original form.
•   Encryption. Encryption is the process of transforming information to make it unreadable to anyone who
    does not have a valid security key. There are two types of encryption, symmetric and asymmetric.
    Symmetric encryption uses a shared key to decrypt or encrypt information. Asymmetric encryption uses a
    private key to encrypt and a public key to decrypt.
As a component of the Itron ChoiceConnect solution, the 100W-R+ and 100WP-R+ modules supports the
Itron Security Manager model found in the ChoiceConnect solution for both reading and programming. If the
100W-R+ and 100WP-R+ modules are shipped without security enabled, the utility can, at a later date,
configure the ERT modules for security.

Enabling 100W-R+ and 100WP-R+ Security
When 100W-R+ and 100WP-R+ modules ship from an Itron factory, each module contains a utility factory
key. The presence of this utility factory key does not enable security. The installer enables 100W-R+ and
100WP-R+ security using an Itron programming device and programming commands. Initial key exchange
commands are secured using the utility factory key. For more information about programming the 100W-R+
and 100WP-R+, see the FDM Endpoint Tools Mobile Application Guide (TDC-0934).


Battery Life
Powered by two non-replaceable, long-life lithium batteries, the 100W has an expected battery life of 20 years
when the ERT module operates in default mobile or fixed network operating mode. If the 100W series ERT
module is programmed for Hard to Read Mobile Mode, the battery life is reduced to 13 years. To proactively
indicate the battery has reached a <10% useful battery life, a Low Battery flag is set to indicate impending
battery failure. Battery life is 15 years for the 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT Module
when ERT module cable lengths exceed 150 feet.




TDC-0951-006 100W-R/100W-R+ and 100WP-R/100WP-R+ Datalogging ERT Module Installation Guide              5
                                          Proprietary and Confidential


About the 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT Modules




100W-R/100W-R+ and 100WP-R/100WP-R+ ERT Module
Transmission Modes
The 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT module can be set to transmit in fixed network,
mobile high power, mobile and handheld, or hard to read mobile and handheld mode.
•   Fixed Network Mode. The 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT module transmits a high-
    powered NIM RF message every six minutes and a contingency SCM+ RF message every minute.
•   Mobile and Handheld Mode. The 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT module transmits
    a medium-powered SCM+ RF message every 9 seconds.
•   (Optional) Mobile High Power Mode. The 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT module
    transmits a high-powered SCM+ RF message every 60 seconds.
•   (Optional) Hard to Read Mobile Mode. The 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT
    module transmits a high-powered SCM+ RF message every 30 seconds. The hard-to-read mobile and
    handheld mode should only be used for exceptionally hard-to-read applications.
    Note The 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT module's battery life is significantly
    affected in hard to read mobile mode. You may use the 900 MHz Remote Antenna to increase reading
    range.
An FCC license is not required to read 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT modules.


100W-R/100W-R+ Operating Modes
1. Factory mode
   • 100W-R/100W-R+ modules ship from the factory in factory mode.
   • The ERT module's transmitter is off.
   • The ERT module's receiver bubbles-up to listen for a programming command.
   • 100W-R/100W-R+ encoder models attempt to read the register every hour.
   • Last good read and extended tamper flags may be set when a register is not connected.
   • If the 100W-R/100W-R+ reads a connected register, the ERT module automatically moves to run
      mode (100W-R/100W-R+ only).
2. Run mode
   • 100W-R/100W-R+ normal operation mode.
   • The 100W-R/100W-R+ transmitted message is dependent on its factory settings or setting
      programmed with FDM for standard consumption messages (SCM or SCM+) or network interval
      message (NIM).
       For SCM (mobile), the 100W+ default bubble-up rate is 9 seconds.
       For NIM (fixed network), the 100W default bubble-up rate is five minutes. When the ERT module is
       set for NIM, the 100W-R/100W-R+ transmits a contingency SCM or SCM+ message every minute.
       Program FN mode with a programming device to configure NIM mode.
3. Meter manufacturer quiet mode
   • Meter manufacturers can configure the ERT module for quiet mode after initializing and direct
      mounting the 100W-R/100W-R+ in the factory.
   • The ERT module awakens from quiet mode and enters run mode in one of two ways:

TDC-0951-006 100W-R/100W-R+ and 100WP-R/100WP-R+ Datalogging ERT Module Installation Guide         6
                                        Proprietary and Confidential


About the 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT Modules



      1. The 100W-R/100W-R+ detects consumption at the top of the hour (last hourly interval >1 or <-1).
      2. The 100W-R/100W-R+ receives a two-way command (for example, a Read ERT using FDM
          software).
4. GEO mode
   • To reach the head end, 100W-R+ establishes a communication link with a CCU.
   • In the event communications are lost with the host CCU, FDM is used to enable communications
     (create a geo mode set) with a nearby 100W-R+.
   • The ERT establishes communications with the new device and continues transmitting NIM messages.


100WP-R/100WP-R+ Operating Modes
The 100WP-R/100WP-R+ has three standard operating modes.
5. Factory Mode
•  100WP-R/100WP-R+ modules ship from the factory in factory mode.
•  The 100WP-R/100WP-R+'s transmitter is off.
•  The 100WP-R/100WP-R+'s receiver bubbles-up to listen for a programming command.
•  Last good read and extended tamper flags may be set when a register is not connected.
•  You must program the 100WP-R/100WP-R+ with the initial consumption and the register type to properly
   move the ERT module to run mode and record consumption. You can program the 100WP-R/100WP-R+
   in the field with FDM or in the factory using custom programming.
6. Run mode
• 100WP-R/100WP-R+s normal operation mode.
• The 100WP-R/100WP-R+ transmitted message is dependent on its factory settings for standard
   consumption messages (SCM or SCM+) or network interval message (NIM).
   • For SCM/SCM+, the 100WP-R/100WP-R+ default bubble-up rate is 9 seconds.
   • For NIM, the 100WP-R/100WP-R+ default bubble-up rate is 6 minutes. When the ERT module is set
       for NIM, the 100WP-R/100WP-R+ transmits a contingency SCM/SCM+ message every minute. NIM
       mode is configured by programming NIM mode with a programming device.
3. Meter manufacturer quiet mode
• Meter manufacturers can configure the ERT module for quiet mode after programming and direct
   mounting the 100WP-R/100WP-R+ in a factory.
• The 100WP-R/100WP-R+ is awakened from quiet mode and enters run mode in one of two ways:
   • Counting two pulses. The pulses are counted internal to the 100WP-R/100WP-R+ while it is in quiet
       mode.
   • Receiving a two-way command, such as a Read ERT using FDM.
• If an ERT module installed in quiet mode is not bubbling up SCM/SCM+ or NIM messages, it may be due
   to zero consumption on the ERT module, such as a vacant or vacation home. Initiate a two-way command
   (for example, perform a Read ERT with FDM) before removing the unit.
4. GEO mode
   • To reach the head end, 100WP-R+ establishes a communication link with a CCU.
   • In the event communications are lost with the host CCU, FDM is used to enable communications
       (create a geo mode set) with a nearby 100WP-R+.
TDC-0951-006 100W-R/100W-R+ and 100WP-R/100WP-R+ Datalogging ERT Module Installation Guide        7
                                        Proprietary and Confidential


About the 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT Modules



   •   The ERT establishes communications with the new device and continues transmitting NIM messages.



100W-R/100W-R+ and 100WP-R/100WP-R+ ERT Module Geo
Mode
100W-R+ and 100WP-R+ module geo mode reduces infrastructure requirements by improving network
coverage. The 100W/100W+ series geo mode technology addresses meters with isolated RF impairments
allowing hard-to-read ERT modules to be read by a neighboring ERT module with good network coverage.
The ERT module forwards the hard-to-read ERT module's message to the nearest data collection device.




TDC-0951-006 100W-R/100W-R+ and 100WP-R/100WP-R+ Datalogging ERT Module Installation Guide       8
                                        Proprietary and Confidential


CHAPTER 3

Initializing, Programming, and Connecting the ERT Module

This chapter provides the instructions to initialize and start up the 100W-R/100W-R+ ERT module, program
and start up the 100WP-R/100WP-R+, and connect the 100W-R/100W-R+ or 100WP-R/100WP-R+ ERT
module.


Initializing the 100W-R/100W-R+
         Caution To obtain an immediate reading, initialize the 100W-R/100W-R+ with an approved
         handheld computer. Failure to initialize the ERT module may delay the initial reading up to one
         hour.

•   To initialize the 100W-R/100W-R+ immediately, use one of the following handheld computers running
    Field Deployment Manager (FDM) version 3.2 or later.
    • FC200SR handheld computer (Itron part number FC2-0005-004 or FC2-0006-004)
    • FC300 with SRead
•   For normal activation, connect the 100W-R/100W-R+ to the water meter register. The ERT module polls
    for a register every hour. The 100W-R/100W-R+ automatically activates after the ERT module detects a
    register.


100W-R/100W-R+ Encoder Start-up
The 100W-R/100W-R+ automatically:
•   Detects the connected register type at the top of the hour, exits factory mode, and enters run mode
    (programming is not required for the 100W-R/100W-R+ to initiate run mode in the default mobile mode).
•   Detects an Itron Leak Sensor.
100W-R/100W-R+ encoder programming is required to:
•   Change the operation mode (for example, to change the ERT module from the default mobile mode to
    fixed network mode).
•   Enter a Utility ID or Lock Type.
•   To enter an E-Coder 8-digit driver.
Itron strongly recommends performing a Check ERT with a handheld computer running FDM to verify the
ERT module is operating correctly after installation. Performing a Check ERT will:
•   Generate an immediate register read.
•   Align the 100W-R/100W-R+'s time with the handheld's time.
    Important Periodically dock or cradle the handheld computer or mobile reader to keep the time current.
•   Verify communication with the Leak Sensor.
•   Check for tamper flags.




TDC-0951-006 100W-R/100W-R+ and 100WP-R/100WP-R+ Datalogging ERT Module Installation Guide                 9
                                          Proprietary and Confidential


Initializing, Programming, and Connecting the ERT Module




Programming the 100WP-R/100WP-R+
Programming the 100WP-R/100WP-R+ requires one of the following handheld computers running Field
Deployment Manager (FDM) version 3.2 or later.
•   FC200SR handheld computer (Itron part number FC2-0005-004 or FC2-0006-004)
•   FC300 with SRead
For normal activation, connect the 100WP-R/100WP-R+ to the water meter register and program the ERT
module with FDM.


100WP-R/100WP-R+ Pulser Start-up
The 100WP-R/100WP-R+ enters run mode by completing programming with FDM. Programming sets the
appropriate pulser parameters (initial consumption and Utility ID).
Itron strongly recommends performing a Check ERT with a handheld computer running FDM to verify the
100WP-R/100WP-R+ is operating correctly after installation. Performing a Check ERT will:
•   Generate an immediate register read.
•   Align the 100WP-R/100WP-R+'s time with the handheld's time.
     Important Periodically dock or cradle the handheld computer or mobile reader to keep the time current.
•   Verify communication with the Leak Sensor.
•   Check for tamper flags.


Connecting the 100W-R/100W-R+ to a Remote Meter Register
Connect the wires from the 100W-R/100W-R+ ERT module to the register screw terminals according to the
following table.
                                                100W-R/100W-R+ wire color
                             Brown (data)            Gray                    Yellow
                                                 (power/clock)              (ground)

Register Manufacturer                        Register screw color designator
Elster AMCO Invision               R                  GRN                      BLK
Elster AMCO Scancoder              R                  GRN                      BLK
Elster AMCO evoQ4 (Q4000)          R                  White                    BLK
Hersey Translator                GRN                    R                      BLK
Badger ADE                       GRN                    R                      BLK
Sensus ECR (all variants)        GRN                    R                      BLK
Sensus ICE                       GRN                    R                      BLK
Metron Famier                    GRN                    R                      BLK
Itron (Actaris) Coder            GRN                    R                      BLK


TDC-0951-006 100W-R/100W-R+ and 100WP-R/100WP-R+ Datalogging ERT Module Installation Guide            10
                                            Proprietary and Confidential


Initializing, Programming, and Connecting the ERT Module




                                                       100W-R/100W-R+ wire color
                                 Brown (data)                Gray                       Yellow
                                                         (power/clock)                 (ground)
Neptune ProRead
        E-Coder                         R                       B                          G
        ARB-V
Performance ETR                        GRN                      R                        BLK
SevernTrent SM700
SmartMeter                             GRN                      R                        BLK
(Sensus Protocol)




Connecting the 100WP-R/100WP-R+ to a Remote Meter Register
•   Connect the 100WP-R/100WP-R+ wires from the ERT module to the register screw terminals according
    to the following table.
                                                        100WP-R/100WP-R+ wire color
                                          Brown               Gray                Yellow
                                         (signal)          (common)              (tamper)
    Register Manufacturer
                                                       Register screw color designator

    Elster Digital
                                            BLK                 GRN                        R

    Itron (Actaris) Cyble Sensor (2-                       Remaining wire must be connected to both ERT
    wire)                               Either wire
                                                                          module wires
    Badger RTR                               R                  BLK                   Green/bare
    Elster V100                             BLK                     R                    Blue
    Sensus PMM                               R                  BLK                      Bare

Connect the ERT module to the cable using gel-cap connectors (see Using Gel Cap Connectors).




TDC-0951-006 100W-R/100W-R+ and 100WP-R/100WP-R+ Datalogging ERT Module Installation Guide                11
                                                    Proprietary and Confidential


Initializing, Programming, and Connecting the ERT Module




Verifying 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT
Module Operation
Use one of the following handheld computers to verify the ERT module is correctly recording consumption
data.
•   FC200SR
•   FC300 with SRead
             Caution
                  •   Each handheld radio requires special setup and configuration parameters to
                      successfully read and program 100W/100W+ modules. Refer to the respective
                      meter reading application for specific instructions.
                  •   Do not use ReadOne Pro, FS2PN and FS3PN, or FC200R handhelds to read the
                      100WP-R/100WP-R+. These readers do not operate their receivers long enough
                      or at the right frequency to reliably capture a 100WP-R/100WP-R+ transmission.
Refer to the user guide for your programming device (see Related Documents) and data collection application
for more information.




TDC-0951-006 100W-R/100W-R+ and 100WP-R/100WP-R+ Datalogging ERT Module Installation Guide             12
                                            Proprietary and Confidential


CHAPTER 4

Installing the 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT
Module

Install the 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT modules using one of the following mounting
options:
100W-R/100W-R+ and 100WP-R/100WP-R+ ERT module Mounting Options
Pipe Mount                     The ERT module mounts to a pipe near the meter (see Pipe Mount Installation). This option requires the
                               Remote Mount Kit and the appropriate Pipe Mount Kit.
Remote Mount                   The ERT module mounts to a flat surface and connects to the meter register with a cable up to 300 feet
                               (see Remote Mount Installation). This option requires the Remote Mount Kit.
Direct Meter Register          The ERT module mounts directly to a meter register designed for ERT module direct mounting. This
Mount                          installation does not require a mounting kit (see Direct-Mounting to the Meter Register).




100W-R/100W-R+ and 100WP-R/100WP-R+ ERT Module
Accessories
100W-R/100W-R+/100WP-R/100WP-R+ Mounting Accessories
Accessory                                                                                       Part Number
Remote Mount Kit (Encoder/Pulser only)                                                          CFG-0771-021
Remote Mount Kit (Encoder/Pulser with Leak Sensor)                                              CFG-1300-003

Pipe Mount Kit
     pipes from 3/4 to 1 3/4 inches                                                             CFG-0217-503
     pipes from 1 5/16 to 2 1/4 inches                                                          CFG-0217-504
     pipes up to 4 inches                                                                       CFG-0217-501
Direct Mount Screw Pack
     Bulk                                                                                       SCR-0010-005
     80 per bag                                                                                 SCR-0010-004
     122 per bag                                                                                SCR-0010-001




TDC-0951-006 100W-R/100W-R+ and 100WP-R/100WP-R+ Datalogging ERT Module Installation Guide                                      13
                                                   Proprietary and Confidential


Installing the 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT Module




Installing 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT
Module Cable Strain Relief
After you complete the ERT module to register or ERT module to register and Leak Sensor connections (for
more information, see Connecting the Leak Sensor to the 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT
Module), install a cable tie to the meter cable (and Leak Sensor cable, if applicable) just below the exposed
colored lead wires on the cable insulation. The cable tie performs as a cable strain relief to reduce the risk of
destructive tension on the lead wires.

Required Materials
•   Remote Mount Kit
    • CFG-0771-021, single cable port for register connection
    • CFG-1300-003, dual cable ports for Leak Sensor and register connection
•   Sidecutter pliers
•   Gel connector crimping tool
•   Cable tie gun
•   Torx T-15 screwdriver

To install the remote ERT module cable strain relief
1. Wrap the cable tie around the meter register or Leak Sensor cable.




TDC-0951-006 100W-R/100W-R+ and 100WP-R/100WP-R+ Datalogging ERT Module Installation Guide                 14
                                           Proprietary and Confidential


Installing the 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT Module



2. Insert the pointed end of the cable tie into the receptacle end of the cable tie with the ribbed edge facing
   in.




3. Pull the pointed end of the cable tie until hand tight. Insert the excess cable tie into the cable tie gun. Pull
   the cable gun trigger to tighten and clip the excess cable tie. The cable tie gun shown is equipped with a
   red dial to set the cable tightening pressure of the gun.




    Note If your cable tie gun is equipped with a dial to set the tightening pressure, set the pressure to ensure
    the cable tie is secure on the lead wire. After installation, the cable tie must not move on the register or
    Leak Sensor lead wire.
4. If your cable tie gun does not have a clipping feature, remove the cable tie from the cable tie gun. Using a
   sidecutter pliers, remove the excess cable tie.




TDC-0951-006 100W-R/100W-R+ and 100WP-R/100WP-R+ Datalogging ERT Module Installation Guide                   15
                                            Proprietary and Confidential


Installing the 100W-R/100W-R+ and 100WP-R/100WP-R+ ERT Module



5. Place the cable connection(s) into the ERT module housing with the cable ties to the inside.




    Note The image shown above illustrates the dual cable strain relief for the register and Leak Sensor.


Attaching the Backplate
Select the appropriate remote mount kit for your 100W ERT module (see 100W-R/100W-R+ and 100WP-
R/100WP-R+ ERT Module Accessories). Attach the ERT module's backplate before completing a Remote
Mount or Pipe Mount installation.

To attach an encoder/pulser only backplate
1. Route the register cable through the single backplate cutout. Ensure the cable strain relief is inside the
   module housing and backplate assembly.




TDC-0951-006 100W-R/100W-R+ and 100WP-R/100WP-R+ Datalogging ERT Module Installation Guide                 16
                                           Proprietary and Confidential



Document Created: 2012-11-12 12:14:03
Document Modified: 2012-11-12 12:14:03