 REGULATORY COMPLIANCE REPORT
TITLE: FCC & IC Test Report for 15.247 & RSS-210 Frequency Hopping Device
100T COMMUNICATION MODULE-CATHODIC PROTECTION

AUTHOR: Mark Kvamme

 REV         CCO         DESCRIPTION OF CHANGE                              DATE          APPROVALS
                                                                                               Engineering
  001                    INITIAL RELEASE
                                                                                                Regulatory


                                             REVISION HISTORY
                                                                            07dec12            Engineering
    a                    initial upload
                                                                                                Regulatory

                                                                            03jan13            Engineering
    b                    update RBW
                                                                                                Regulatory

                                                                                               Engineering

                                                                                                Regulatory

                                        NOTICE OF PROPRIETARY INFORMATION
 Information contained herein is proprietary and is property of ITRON, Inc. where furnished with a proposal, the recipient shall use it
 solely to evaluate the proposal. Where furnished to a customer it shall be used solely for the purposes of inspection, installation or
 maintenance. Where furnished to a supplier, it shall be used solely in the performance of work contracted for this company. The
 information shall not be used or disclosed by the recipient for any other purpose, whatsoever.




100tcp_report mpeb.docx                                                                                                           Rev. b


                                                                                                 FCC-1000-003-mpe
                                                                                                       Page 2 of 3
Test Data Summary
                FCC 15.247 / IC RSS-210; Frequency Hopping Transmitter; 100TCP
  100T COMMUNICATION MODULE-CATHODIC PROTECTION, 903MHz – 926.85 MHz for EUT
                  FCC ID/ IC: EWQ100TCP/ 864D-100TCP IC Device Models : CP
                       OATS Registration Number: FCC 90716, IC 864D-1
                                                        Spec                                                        Pass/
             Rule                    Description        Limit            Max. Reading                                Fail
       Parts 1.1310 &            Limits for Maximum
  2.1091(mobile) or 2.1093      Permissible Exposure            0.169 mW / cm2 @ 20 cm
(portable) / RSS-102 Sec 4.2            (MPE)         formula 1.69 W/M2 @ 0.2 M                                     Pass
Rule versions: FCC Part 1; FCC Part 2; FCC Part 15, RSS-102 Issue 4 (03-2010); RSS-210 Issue 8 (12-2010); RSS-Gen
Issue 3 (12-2010).
Reference docs: ANSI C63.4-2003; DA 00-705 (03-30-2000); OET65 (08-1997); OET65C (06-2001); IEEE C95.3-2002.



                                            Cognizant Personnel
                            Name                                             Title
                         Mark Kvamme                                   Test Technician

                             Name                                          Title
                          Jay Holcomb                               Regulatory Manager

                             Name                                            Title
                        Johann De Jager                                  Project Lead


                                      CONDITIONS DURING TESTING

No Modifications to the EUT were necessary during the testing.

FCC 15.31(m) – IC _n/a_; Number of Channels
This device was tested on three channels.

ANSI C63.4 - Temperature and Humidity During Testing
The temperature during testing was within +10º C and +40º C.
The Relative humidity was between 10% and 90%.
RSS-Gen 4.3: Tests shall be performed at ambient temperature

EQUIPMENT UNDER TEST (EUT) DESCRIPTION
Itron declares that the EUT tested was representative of a production unit.

EQUIPMENT UNDER TEST

EUT Module
Manuf:                     Itron, Inc.
Itron Model:               100TCP
Itron p/n:                 TEL-1000-003
Serial Number(s)           1129328690,1129328697,1129328699
Power source               Fresh Batteries were used

Plot Information
In the zero span measurements, the line in the display is the trigger level.

Peripheral Devices
None




100tcp_report mpeb.docx                                                                                             Rev. b


                                                                                                    FCC-1000-003-mpe
                                                                                                          Page 3 of 3
1.1310 & 2.1091(mobile) or 2.1093(portable) / RSS-102 Sec 4.2-Canada Safety Code 6; Table 5
Maximum Permissible Exposure (MPE)
Radiofrequency radiation exposure limits. - The criteria listed in Table 1 shall be used to evaluate the environmental
impact of human exposure to radiofrequency (RF) radiation as specified in §1.1307(b), except in the case of
portable devices which shall be evaluated according to the provisions of §2.1093 of this chapter.

1.1307 (b) In addition to the actions listed in paragraph (a) of this section, Commission actions granting
construction permits, licenses to transmit or renewals thereof, equipment authorizations or modifications in
existing facilities, require the preparation of an Environmental Assessment (EA) if the particular facility, operation
or transmitter would cause human exposure to levels of radiofrequency radiation in excess of the limits in
§§1.1310 and 2.1093 of this chapter.



           1129328690                   1129328697
               Field                    conducted       conducted     antenna      antenna
 Power       strength       EIRP          power           power         gain         gain
  level     (dBuV/m)        (dbm)         (dbm)           (watts)      (dbi)       numeric
    3        123.29         29.29          22.47          0.177         6.82         4.81
    2        121.27         27.27          21.78          0.151         5.49         3.54
    1        108.82         14.82           9.00          0.008         5.82         3.82

Determine the maximum power density for the general / uncontrolled population minimum
separation distance of 20 cm. (fMHz / 1500 mW/cm2 == fMHz / 150 W/M2 )
The power density is calculated as:

           Pd = power density in mW/cm2
                                                                           Pt × G
           Pt = transmit power in milliwatts                       Pd =
                                                                          4×π × r2
           G = numeric antenna gain
           r = distance between body and transmitter in centimeters.

FCC Limits:                          926.8MHz / 1500 = 0.618 mW / cm2 @ 20cm
IC Limits:                           926.8MHz / 150 = 6.18 W / M2 (@ 0.2M)

Power level 3
Max antenna gain = 6.82 dBi = 4.81 numeric
Max TX power = 22.47 dBm = 177 milliwatts
results:      PD = (177 x 4.81) / ( 4 x pi x 20cm2) = 0.169 mW / cm2 @ 20 cm
               W/m2 = 10 times mW/cm2                     = 1.69 W/M2 @ 0.2 M

Power level 2
Max antenna gain = 5.49 dBi = 3.54 numeric
Max TX power = 21.78 dBm = 151 milliwatts
results:      PD = (151 x 3.54) / ( 4 x pi x 20cm2) = 0.106 mW / cm2 @ 20 cm
               W/m2 = 10 times mW/cm2                     = 1.06 W/M2 @ 0.2 M

Power level 1
Max antenna gain = 5.82 dBi = 3.82 numeric
Max TX power = 9.00 dBm = 8 milliwatts
results:      PD = (8 x 3.82) / ( 4 x pi x 20cm2) = 0.006 mW / cm2 @ 20 cm
               W/m2 = 10 times mW/cm2                     = 0.06 W/M2 @ 0.2 M