MPE calculation

FCC ID: EWQ100GDLRS

RF Exposure Info

Download: PDF
FCCID_1926651

                                                                                                             FCC-5006-007-mpe
                                                                                                                   Page 1 of 4


 REGULATORY COMPLIANCE REPORT
TITLE: FCC & IC MPE Report for 15.247 & RSS-210 Frequency Hopping Device
Remote FCC ID: EWQ100GDLRS IC: 864D-100GDLRS IC Model: 7S
AUTHOR: Mark Kvamme
 REV         CCO         DESCRIPTION OF CHANGE                              DATE          APPROVALS
                                                                                               Engineering
  001                    INITIAL RELEASE
                                                                                                Regulatory


                                             REVISION HISTORY
                                                                                               Engineering
    a                    initial upload
                                                                                                Regulatory

                                                                                               Engineering

                                                                                                Regulatory

                                                                                               Engineering

                                                                                                Regulatory

                                        NOTICE OF PROPRIETARY INFORMATION
 Information contained herein is proprietary and is property of ITRON, Inc. where furnished with a proposal, the recipient shall use it
 solely to evaluate the proposal. Where furnished to a customer it shall be used solely for the purposes of inspection, installation or
 maintenance. Where furnished to a supplier, it shall be used solely in the performance of work contracted for this company. The
 information shall not be used or disclosed by the recipient for any other purpose, whatsoever.




100gdlrs mpe.docx                                               Rev. a


                                                                              FCC-5006-007-mpe
                                                                                    Page 2 of 4
Test Data Summary
                   FCC 15.247 / IC RSS-210; Frequency Hopping Transmitter;
                       100G DLS – Remote, 903MHz – 926.85 MHz for EUT
              FCC ID: EWQ100GDLRS IC: 864D-100GDLRS IC Device Models: 7S
               Part Numbers: ERG-5006-501/502/503/505 Serial Numbers: 105,16,18
                      OATS Registration Number: FCC 90716, IC 864D-1
                                                       Spec                                Pass/
             Rule                    Description        Limit          Max. Reading         Fail
                                                                Power level 1
                                                                = 0.006 mW / cm2 @ 20 cm
                                                                = 0.06 W/M2 @ 0.2 M
                                                                Power level 2
Parts 1.1310 &                                                  = 0.111 mW / cm2 @ 20 cm
2.1091(mobile) or 2.1093                                        = 1.11 W/M2 @ 0.2 M
(portable) / RSS-102 Sec         Limits for Maximum             Power level 3
4.2-Canada Safety Code 6;       Permissible Exposure            = 0.227 mW / cm2 @ 20 cm
Table 5                                 (MPE)         formula = 2.27W/M2 @ 0.2 M           Pass
Rule versions: FCC Part 1; FCC Part 2; FCC Part 15, RSS-102 Issue 4 (03-2010);
RSS-210 Issue 8 (12-2010); RSS-Gen Issue 3 (12-2010).
Reference docs: ANSI C63.4-2003; DA 00-705 (03-30-2000); OET65 (08-1997);
OET65C (06-2001); IEEE C95.3-2002.

                                      Cognizant Personnel
                        Name                                      Title
                     Mark Kvamme                            Test Technician

                        Name                                   Title
                     Jay Holcomb                        Regulatory Manager

                         Name                                    Title
                    Johann De Jager                          Project Lead




100gdlrs mpe.docx                              Rev. a


                                                                               FCC-5006-007-mpe
                                                                                     Page 3 of 4


                                   CONDITIONS DURING TESTING

No Modifications to the EUT were necessary during the testing.

FCC 15.31(m) – IC _n/a_; Number of Channels
This device was tested on three channels.

ANSI C63.4 - Temperature and Humidity During Testing
The temperature during testing was within +10º C and +40º C.
The Relative humidity was between 10% and 90%.
RSS-Gen 4.3 (g): Tests shall be performed at ambient temperature

EQUIPMENT UNDER TEST (EUT) DESCRIPTION
Itron declares that the EUT tested was representative of a production unit.

EQUIPMENT UNDER TEST

EUT Module
Manuf:                   Itron, Inc.
Itron p/n:               ERG-5006-501/502/503/505
Serial Number(s)         Listed Below
Power source             Fresh Batteries were used

Plot Information
In the zero span measurements, the line in the display is the trigger level.

Peripheral Devices
None




100gdlrs mpe.docx                                    Rev. a


                                                                                                    FCC-5006-007-mpe
                                                                                                          Page 4 of 4
1.1310 & 2.1091(mobile) or 2.1093(portable) / RSS-102 Sec 4.2-Canada Safety Code 6; Table 5
Maximum Permissible Exposure (MPE)
Radiofrequency radiation exposure limits. - The criteria listed in Table 1 shall be used to evaluate the environmental
impact of human exposure to radiofrequency (RF) radiation as specified in §1.1307(b), except in the case of
portable devices which shall be evaluated according to the provisions of §2.1093 of this chapter.

1.1307 (b) In addition to the actions listed in paragraph (a) of this section, Commission actions granting
construction permits, licenses to transmit or renewals thereof, equipment authorizations or modifications in
existing facilities, require the preparation of an Environmental Assessment (EA) if the particular facility, operation
or transmitter would cause human exposure to levels of radiofrequency radiation in excess of the limits in
§§1.1310 and 2.1093 of this chapter.


               unit 103                   unit 105
                 Field                   conducted      conducted     antenna      antenna
  Power        strength       EIRP         power          power         gain         gain
   level      (dBuV/m)        (dbm)        (dbm)          (watts)      (dbi)       numeric
     3          124.58        30.58         25.06         0.321         5.52         3.56
     2          121.46        27.46         21.71         0.148         5.75         3.76
     1          109.04        15.04         6.01          0.004         9.03         8.00

Determine the maximum power density for the general / uncontrolled population minimum
separation distance of 20 cm. (fMHz / 1500 mW/cm2 == fMHz / 150 W/M2 )
The power density is calculated as:

           Pd = power density in mW/cm2
                                                                           Pt × G
           Pt = transmit power in milliwatts                       Pd =
                                                                          4×π × r2
           G = numeric antenna gain
           r = distance between body and transmitter in centimeters.

FCC Limits:                           926.8MHz / 1500 = 0.618 mW / cm2 @ 20cm
IC Limits:                            926.8MHz / 150 = 6.18 W / M2 (@ 0.2M)

Power level 3
Max antenna gain = 5.52 dBi = 3.56 numeric
Max TX power = 25.06 dBm = 321 milliwatts
results:      PD = (321 x 3.56) / ( 4 x pi x 20cm2) = 0.227 mW / cm2 @ 20 cm
               W/m2 = 10 times mW/cm2                     = 2.27W/M2 @ 0.2 M

Power level 2
Max antenna gain = 5.75 dBi = 3.76 numeric
Max TX power = 21.71 dBm = 148 milliwatts
results:      PD = (148 x 3.76) / ( 4 x pi x 20cm2) = 0.111 mW / cm2 @ 20 cm
               W/m2 = 10 times mW/cm2                     = 1.11 W/M2 @ 0.2 M

Power level 1
Max antenna gain = 9.03 dBi = 8.00 numeric
Max TX power = 6.01 dBm = 4 milliwatts
results:      PD = (4 x 8.00) / ( 4 x pi x 20cm2) = 0.006 mW / cm2 @ 20 cm
               W/m2 = 10 times mW/cm2                     = 0.06 W/M2 @ 0.2 M