RF Exposure

FCC ID: EW780-1500-00

RF Exposure Info

Download: PDF
FCCID_4401657

                                   SGS-CSTC Standards Technical Services Co., Ltd.
                                   Shenzhen Branch




                                                                          Report No.: HKEM190600056203
                                                                          Page:       1 of 8
1    Cover page

           RF Exposure Evaluation Report
Application No.:                HKEM1906000562AT
Applicant:                      VTech Telecommunications Ltd.
Address of Applicant:           23/F, Tai Ping Industrial Centre, Block 1,57 Ting Kok Road, Tai Po, Hong
                                Kong.
Manufacturer:                   VTech Telecommunications Ltd.
Address                   of    23/F, Tai Ping Industrial Centre, Block 1,57 Ting Kok Road, Tai Po, Hong
Manufacturer:                   Kong.
Factory:                        VTech (Dongguan) Telecommunications Limited.
Address of Factory:      VTech Science Park, Xia Ling Bei Management Zone, Liaobu, Dongguan,
                         Guangdong, China.
Equipment Under Test (EUT):
Product Name:            Pan and Tilt Video Monitor
Model No.:               VM5262 BU, VM5262-2 BU, VM5X62-ab BU ♣
♣                        Please refer to section 4.1 of this report which indicates which model was
                         actually tested and which were electrically identical.
Trade Mark:              VTech
FCC ID:                         EW780-1500-00
Standards:                      47 CFR Part 1.1307 (2016)
                                47 CFR Part 1.1310 (2016)
Date of Receipt:                2019-06-27
Date of Test:                   2019-07-02 to 2019-07-05
Date of Issue:                  2019-08-07
Test Result :                    PASS*

*   In the configuration tested, the EUT complied with the standards specified above.




             Keny Xu
       EMC Laboratory Manager


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                          Report No.: HKEM190600056203
                                                          Page:       2 of 8

2 Version

                                        Revision Record
      Version        Chapter         Date                 Modifier     Remark

      01                             2019-08-07                        Original




  Authorized for issue by:




                                Vincent Chen /Project Engineer




                                Eric Fu /Reviewer


                                              SGS-CSTC Standards Technical Services Co., Ltd.
                                              Shenzhen Branch
                                                                                                 Report No.: HKEM190600056203
                                                                                                 Page:       3 of 8

3         Contents
                                                                                                                                                     Page
1      COVER PAGE ........................................................................................................................................ 1

2      VERSION ................................................................................................................................................ 2

3      CONTENTS ............................................................................................................................................ 3

4      GENERAL INFORMATION ..................................................................................................................... 4
    4.1    GENERAL DESCRIPTION OF EUT ............................................................................................................. 4
    4.2    TEST LOCATION..................................................................................................................................... 5
    4.3    TEST FACILITY ...................................................................................................................................... 5
    4.4    DEVIATION FROM STANDARDS ................................................................................................................. 6
    4.5    ABNORMALITIES FROM STANDARD CONDITIONS ......................................................................................... 6
    4.6    OTHER INFORMATION REQUESTED BY THE CUSTOMER ............................................................................... 6
5      RF EXPOSURE EVALUATION ............................................................................................................... 7
    5.1 RF EXPOSURE COMPLIANCE REQUIREMENT ............................................................................................. 7
       5.1.1 Limits .......................................................................................................................................... 7
       5.1.2 Test Procedure ........................................................................................................................... 7
    4.1.3 EUT RF EXPOSURE EVALUATION........................................................................................................... 8


                           SGS-CSTC Standards Technical Services Co., Ltd.
                           Shenzhen Branch
                                                              Report No.: HKEM190600056203
                                                              Page:       4 of 8


4   General Information

4.1 General Description of EUT
    Power supply:              Adapter model: S005BNU0500080
                               Input: AC 100-240V, 50/60Hz, 150mA
                               Output: DC 5V, 800mA
    Cable:                     DC Cable from adapter 186cm unshielded
    Operation Frequency:       2405-2475MHz
    Modulation Type:           GFSK
    Number of Channels:        32
    Channel Spacing:           2MHz
    Antenna Type:              Dipole Antenna
    Antenna Gain:              0dBi


    Declaration of EUT Family Grouping:

    Model No.: VM5262 BU, VM5262-2 BU, VM5X62-ab BU

    Only the model VM5262 BU was tested, since the electrical circuit design, layout, components used,
    internal wiring and functions were identical for the above models, with only difference on color and
    model number.


                              SGS-CSTC Standards Technical Services Co., Ltd.
                              Shenzhen Branch
                                                               Report No.: HKEM190600056203
                                                               Page:       5 of 8




4.2 Test Location
    All tests were performed at:
    SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch
    No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong, China
    518057
    Telephone: +86 (0) 755 2601 2053    Fax: +86 (0) 755 2671 0594
    No tests were sub-contracted.

4.3 Test Facility
    The test facility is recognized, certified, or accredited by the following organizations:
    • CNAS (No. CNAS L2929)
    CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
    Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
    Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
    Laboratories) for the competence in the field of testing.
    • A2LA (Certificate No. 3816.01)
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
    American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
    • VCCI
    The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
    Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
    Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have
    been registered in accordance with the Regulations for Voluntary Control Measures with Registration
    No.: G-20026, R-14188, C-12383 and T-11153 respectively.
    • FCC –Designation Number: CN1178
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    as an accredited testing laboratory.
    Designation Number: CN1178. Test Firm Registration Number: 406779.
    • Innovation, Science and Economic Development Canada
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    by ISED as an accredited testing laboratory.
    CAB identifier: CN0006.
    IC#: 4620C.


                    SGS-CSTC Standards Technical Services Co., Ltd.
                    Shenzhen Branch
                                             Report No.: HKEM190600056203
                                             Page:       6 of 8


4.4 Deviation from Standards
   None.

4.5 Abnormalities from Standard Conditions
   None.

4.6 Other Information Requested by the Customer
   None.


                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch
                                                                  Report No.: HKEM190600056203
                                                                  Page:       7 of 8


5       RF Exposure Evaluation

5.1     RF Exposure Compliance Requirement
5.1.1 Limits
        According to FCC Part1.1310: The criteria listed in the following table shall be used to evaluate the
        environment impact of human exposure to radio frequency (RF) radiation as specified in part1.1307(b)




F= Frequency in MHz
Friis Formula
Friis transmission formula: Pd = (Pout*G)/(4* Pi * R 2)
Where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416

R = distance between observation point and center of the radiator in cm
Pd id the limit of MPE, 1 mW/cm2 . If we know the maximum gain of the antenna and the total power input to
the antenna, through the calculation, we will know the distance r where the MPE limit is reached.

5.1.2 Test Procedure
        Software provided by client enabled the EUT to transmit and receive data at lowest, middle and
        highest channel individually.


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                                    Report No.: HKEM190600056203
                                                                    Page:       8 of 8


4.1.3 EUT RF Exposure Evaluation

Antenna Gain: 0dBi
Antenna Gain: The maximum Gain measured in fully anechoic chamber is 1.00 in linear scale.
Output Power Into Antenna & RF Exposure Evaluation Distance:

 Channel     Frequency      Max Conducted        Output Power        Power Density      Limit    Result
                (MHz)         Peak Output          to Antenna         at R = 20 cm
                                                                                 2
                             Power (dBm)              (mW)             (mW/cm )
  Middle         2442             17.43               55.34              0.011           1.0      PASS


Note: Refer to report No. HKEM190600056202 for EUT test Max Conducted Peak Output Power value.
The distance r (4th column) calculated from the Fries transmission formula is far greater than 20 cm
separation requirement.



                                            - End of the Report -