RF Exposure Info

FCC ID: EW780-1331-00

RF Exposure Info

Download: PDF
FCCID_4478380

                                   SGS-CSTC Standards Technical Services Co., Ltd.
                                   Shenzhen Branch




                                                                         Report No.: HKEM190600056303
                                                                         Page:       1 of 7
1    Cover page


           RF Exposure Evaluation Report
Application No.:                 HKEM1906000563AT
Applicant:                       VTech Telecommunications Ltd
Address of Applicant:            23/F Block 1, Tai Ping Inductrial Centre, 57 Ting Kok Road, Tai Po, New
                                 Territories, Hong Kong
Manufacturer:                    VTech Telecommunications Ltd
Address of Manufacturer:         23/F, Tai Ping Inductrial Centre, Block 1, 57 Ting Kok Road, Tai Po, Hong
                                 Kong
Factory:                         VTech (Dongguan) Telecommunications Limited.
Address of Factory:              VTech Science Park, Xia Ling Bei Management Zone, Liaobu, Dongguan,
                                 Guangdong, China
Equipment Under Test (EUT):
Product Name:                    Full Color Video Monitor
Model No.:                       VM5251 BU, VM5251-2 BU, VM5X51-ab BU ♣
♣                                Please refer to section 4.1 of this report which indicates which model was
                                 actually tested and which were electrically identical.
HVIN:                            35-201248BU
FCC ID:                          EW780-1331-00
Standards:                       47 CFR Part 1.1307 (2016)
                                 47 CFR Part 1.1310 (2016)
Date of Receipt:                 2019-09-04
Date of Test:                    2019-09-05 to 2019-09-08
Date of Issue:                   2019-09-11
Test Result :                      PASS*
*   In the configuration tested, the EUT complied with the standards specified above.




              Keny Xu
        EMC Laboratory Manager


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                             Report No.: HKEM190600056303
                                                             Page:       2 of 7



2 Version

                                           Revision Record
       Version       Chapter               Date                  Modifier       Remark

       01                               2019-09-11                              Original




  Authorized for issue by:




                                Vincent Chen /Project Engineer




                                Eric Fu /Reviewer


                                                SGS-CSTC Standards Technical Services Co., Ltd.
                                                Shenzhen Branch
                                                                                                      Report No.: HKEM190600056303
                                                                                                      Page:       3 of 7




3         Contents
                                                                                                                                                            Page
1       COVER PAGE .............................................................................................................................................. 1

2       VERSION ...................................................................................................................................................... 2

3       CONTENTS .................................................................................................................................................. 3

4       GENERAL INFORMATION .......................................................................................................................... 4
    4.1     GENERAL DESCRIPTION OF EUT ................................................................................................................. 4
    4.2     TEST LOCATION .......................................................................................................................................... 5
    4.3     TEST FACILITY ............................................................................................................................................ 5
    4.4     DEVIATION FROM STANDARDS ..................................................................................................................... 5
    4.5     ABNORMALITIES FROM STANDARD CONDITIONS............................................................................................ 5
    4.6     OTHER INFORMATION REQUESTED BY THE CUSTOMER ................................................................................. 5
5       RF EXPOSURE EVALUATION .................................................................................................................... 6
    5.1 RF EXPOSURE COMPLIANCE REQUIREMENT ................................................................................................ 6
       5.1.1 Limits ................................................................................................................................................ 6
       5.1.2 Test Procedure ................................................................................................................................ 6
       5.1.3 EUT RF Exposure Evaluation .......................................................................................................... 7


                            SGS-CSTC Standards Technical Services Co., Ltd.
                            Shenzhen Branch
                                                                Report No.: HKEM190600056303
                                                                Page:       4 of 7


4   General Information

4.1 General Description of EUT
    Power Supply:               Adapter model: S003GU0500060
                                Input: AC 100-240V, 50/60Hz, 150mA
                                Output: DC 5V, 600mA
    Operation Frequency:        2405-2475MHz
    Modulation Type:            GFSK
    Number of Channels:         32
    Channel Spacing:            2MHz
    Antenna Type:               Dipole Antenna
    Antenna Gain:               0dBi


    Remark:
    Model No.: VM5251 BU, VM5251-2 BU, VM5X51-ab BU
    Only the model VM5251 BU was tested, since the electrical circuit design, layout, components used,
    internal wiring and functions were identical for all the above models, with only difference on color and
    model No. other different as below show:
    x=any alphanumeric character is presenting different packaging
    a=any alphanumeric character or blank is presenting number of baby unit.
    b = any alphanumeric character or blank is presenting color of enclosure


                              SGS-CSTC Standards Technical Services Co., Ltd.
                              Shenzhen Branch
                                                                Report No.: HKEM190600056303
                                                                Page:       5 of 7


4.2 Test Location
    All tests were performed at:
    SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch
    No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong, China
    518057
    Telephone: +86 (0) 755 2601 2053    Fax: +86 (0) 755 2671 0594
    No tests were sub-contracted.

4.3 Test Facility
    The test facility is recognized, certified, or accredited by the following organizations:
    • CNAS (No. CNAS L2929)
    CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
    Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
    Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
    Laboratories) for the competence in the field of testing.
    • A2LA (Certificate No. 3816.01)
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
    American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
    • VCCI
    The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
    Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
    Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have been
    registered in accordance with the Regulations for Voluntary Control Measures with Registration No.: G-
    20026, R-14188, C-12383 and T-11153 respectively.
    • FCC –Designation Number: CN1178
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    as an accredited testing laboratory.
    Designation Number: CN1178. Test Firm Registration Number: 406779.
    • Innovation, Science and Economic Development Canada
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    by ISED as an accredited testing laboratory.
    CAB identifier: CN0006.
    IC#: 4620C.

4.4 Deviation from Standards
    None.

4.5 Abnormalities from Standard Conditions
    None.

4.6 Other Information Requested by the Customer
    None.


                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                 Shenzhen Branch
                                                                     Report No.: HKEM190600056303
                                                                     Page:       6 of 7


5     RF Exposure Evaluation

5.1 RF Exposure Compliance Requirement
5.1.1 Limits
        According to FCC Part1.1310: The criteria listed in the following table shall be used to evaluate the
        environment impact of human exposure to radio frequency (RF) radiation as specified in part1.1307(b)




F= Frequency in MHz
Friis Formula
Friis transmission formula: Pd = (Pout*G)/(4* Pi * R 2)
Where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416

R = distance between observation point and center of the radiator in cm
Pd id the limit of MPE, 1 mW/cm2 . If we know the maximum gain of the antenna and the total power input to
the antenna, through the calculation, we will know the distance r where the MPE limit is reached.

5.1.2 Test Procedure
        Software provided by client enabled the EUT to transmit and receive data at lowest, middle and
        highest channel individually.


                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch
                                                                    Report No.: HKEM190600056303
                                                                    Page:       7 of 7


5.1.3 EUT RF Exposure Evaluation

Antenna Gain: 0dBi
Antenna Gain: The maximum Gain measured in fully anechoic chamber is 1.00 in linear scale.
Output Power Into Antenna & RF Exposure Evaluation Distance:


 Channel     Frequency      Max Conducted        Output Power        Power Density       Limit    Result
                (MHz)         Peak Output          to Antenna         at R = 20 cm
                             Power (dBm)              (mW)              (mW/cm2)
  Lowest         2405             16.44               3.511              0.0014           1.0      PASS


Note: Refer to report No. HKEM190600056301 for EUT test Max Conducted Peak Output Power value.
The distance r (4th column) calculated from the Fries transmission formula is far greater than 20 cm
separation requirement.



                                            - End of the Report -



Document Created: 2019-09-17 02:16:12
Document Modified: 2019-09-17 02:16:12

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC