Test Report V

FCC ID: EUNGE2L

Test Report

Download: PDF
FCCID_677177

              Compliance Certification Services (Kunshan) Inc.
           10#Weiye Rd, Innovation Park, Eco. & Tec. Development Zone Kunshan city JiangSu, (215300) CHINA
            TEL: 86-512-57355888 FAX: 86-512-57370818
           Report No: KS060328A01-RP            FCC ID No.: EUNGE2L              Date of Issue: April 20, 2006


                              Measurement of MPE

1. Foreword
     In adopt with the Human Exposure IEEE C95.1, and according to the FCC 1.1310. The
  Maximum Permissible Exposure (MPE) is obligated to measure in order to prove the safety of
  radiation harmfulness to the human body.

     The Gain of the antenna used is measured in an anechoic chamber. The maximum total
  power to the antenna is to be recorded. By adopting the Friis Transmission Formula and the
  power gain of the antenna, we can find the distance right away from the product, where the
  limit of the MPE is.


2. Limits for Maximum Permissible Exposure (MPE)
     Frequency         Electric Field    Magnetic Filed      Power Density      Averaging Time
       Range          Strength (V/m)      Strength (H)             (S)            |E|2, |H|2 or S
       (MHz)                                  (A/m)            (mW/cm2)             (minutes)
  (A) Limits for Occupational/Controlled Exposure
       0.3-3.0              614                1.63                100                   6
                                                                         2
       3.0-30              1842/f             4.89/f              900/f                  6
       30-300               61.4              0.163                1.0                   6
      300-1500               --                 --                f/300                  6
    1500-100,000             --                 --                  5                    6
  (B) Limits for General Population/Uncontrolled Exposure
      0.3-1.34              614                1.63                100                  30
                                                                         2
       1.34-30             824/f              2.19/f              180/f                 30
       30-300               27.5              0.073                0.2                  30
      300-1500               --                 --                f/1500                30
    1500-100,000             --                 --                 1.0                  30


                  Compliance Certification Services (Kunshan) Inc.
                  10#Weiye Rd, Innovation Park, Eco. & Tec. Development Zone Kunshan city JiangSu, (215300) CHINA
                  TEL: 86-512-57355888 FAX: 86-512-57370818
                  Report No: KS060328A01-RP            FCC ID No.: EUNGE2L              Date of Issue: April 20, 2006


According to OET BULLETIN 56 Fourth Edition/August 1999, Equation for Predicting RF Fields:

                                                              PG     44.77 × 1.63
  Power density at the specific separation (portable): S =         =              = 0.0145mW / cm 2
                                                             4πR 2
                                                                      4π (20) 2




Where: S = power density (in appropriate units, e.g. mW/cm2)
     P = power input to the antenna (in appropriate units, e.g., mW)
     G = power gain of the antenna in the direction of interest relative to an isotropic radiator
     R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)


The Numeric gain G of antenna with a gain specified in dB is determined by:
      G = Log -1 (dB antenna gain/10)
      G = Log -1 (2.13 / 10) = 1.63



Document Created: 2006-04-28 18:51:36
Document Modified: 2006-04-28 18:51:36

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC