RF Exposure Report

FCC ID: EO9OW3

RF Exposure Info

Download: PDF
FCCID_4066254

                               MAXIMUM PERMISSIBLE
                                 EXPOSURE REPORT
                                  (Measurement)
                                                   FOR THE

                                Device: CGR ACT Module 3 (CAM3)
                                          Model: OW3




                                             Report No.: 101674-5



                                         Date of issue: October 11, 2018


PREPARED FOR:
Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019


The test data contained in this report documents the observed testing parameters pertaining to and
are relevant for only the sample equipment tested in the agreed upon operational mode(s) and
configuration(s) as identified herein. Compliance assessment remains the client’s responsibility. This
report may not be used to claim product endorsement by A2LA or any government agencies. This test
report has been authorized for release under quality control from CKC Laboratories, Inc.




                                                   Steve Behm
                              Director of Quality Assurance & Engineering Services
                                             CKC Laboratories, Inc.


                                                                Table of Contents


Test Report Information ............................................................................................................................... 3
Purpose ......................................................................................................................................................... 3
Device and Antenna Operating Configuration .............................................................................................. 3
Test Procedure .............................................................................................................................................. 3
Other Considerations .................................................................................................................................... 3
Equipment Under Test .................................................................................................................................. 4
Data ............................................................................................................................................................... 5
Summary ..................................................................................................................................................... 10
APPENDIX A - Assessment Procedure ......................................................................................................... 11
APPENDIX B - RF Exposure Limits................................................................................................................ 14
APPENDIX C - References ............................................................................................................................ 19




                                                                                                                                               Page 2 of 19
                                                                                                                                       Report No: 101674-5


Test Report Information
Test Location(s):                                 Report Prepared By:
CKC Laboratory, Inc.                              Don Nguyen & Terri Rayle
110 North Olinda Place                            CKC Laboratories, Inc.
Brea, CA 92823                                    5046 Sierra Pines Drive
                                                  Mariposa, CA 95338
Representative: Jay Holcomb                       Date of Equipment Receipt: Sept 12, 2018
Customer Reference Number: 159196                 Date(s) of Testing: September 14, 2018
Project Number: 101674

Purpose:
To demonstrate compliance with United States, Canada, Australia and/or European Union RF Exposure
requirements for Mobile Equipment (devices used >20cm from the body), where MPE measurements
apply.

Device and Antenna Operating Configuration:
Device operating at maximum output power with continuous transmission of modulated data.

Test Procedure:
This equipment is evaluated in accordance with the guidelines set forth in KDB 447498 & ANSI C95.1
for the US, Health Canada Safety Code 6 & RSS 102 for Canada, ARPANSA RPS3 for AU and EN 62479
or EN 62311 for EU.

Other Considerations:
Report considers stand-alone configuration only. RF Exposure limits are calculated at the mid-point of
each operating band. Multi-transmitter devices are assumed to permit simultaneous transmission,
unless indicated otherwise. Simultaneous transmissions aggregated providing a worst case assessment.




                                                                                            Page 3 of 19
                                                                                    Report No: 101674-5


EQUIPMENT UNDER TEST (EUT)

During testing, numerous configurations may have been utilized. The configurations listed below support
compliance to the standard(s) listed in the Summary of Results section.

Configuration 5
Equipment Tested:
Device                  Manufacturer               Model #                    S/N
CGR ACT Module 3 (CAM3) Itron, Inc.                OW3                        FCC-2 (CGR) CAM3-FCC2
                                                                              (CAM Module, ID)
Support Equipment:
Device                     Manufacturer            Model #                    S/N
Connected Grid Router      Cisco Systems, Inc.     CGR 1240                   FTX2204G01J
(Host
Laptop                     Dell                    E6420                      NA
AC Adapter (for Laptop)    Dell                    DA130PE1-00                NA
USB to Ethernet adapter    Linksys                 USB3GIGV1                  NA
2.8dBi Colinear Omni       Cisco Systems, Inc.     07-1140-02                 NA
Antenna (attached)


Configuration 6
Equipment Tested:
Device                                  Manufacturer             Model #      S/N
CGR ACT Module 3 (CAM3)                 Itron, Inc.              OW3          FCC-2 (CGR) CAM3-FCC2
                                                                              (CAM Module, ID)
Support Equipment:
Device                                 Manufacturer           Model #         S/N
Connected Grid Router (Host            Cisco Systems, Inc.    CGR 1240        FTX2204G01J
Laptop                                 Dell                   E6420           NA
AC Adapter (for Laptop)                Dell                   DA130PE1-00     NA
USB to Ethernet adapter                Linksys                USB3GIGV1       NA
5.5dBi Colinear Omni Antenna           Cisco Systems, Inc.    ANT-WPAN-OM-    NA
(remote)                                                      OUT-N


Configuration 7
Equipment Tested:
Device                                 Manufacturer           Model #          S/N
CGR ACT Module 3 (CAM3)                Itron, Inc.            OW3              FCC-2 (CGR) CAM3-FCC2
                                                                               (CAM Module, ID)
Support Equipment:
Device                                 Manufacturer           Model #          S/N
Connected Grid Router (Host            Cisco Systems, Inc.    CGR 1240         FTX2204G01J
Laptop                                 Dell                   E6420            NA
AC Adapter (for Laptop)                Dell                   DA130PE1-00      NA
USB to Ethernet adapter                Linksys                USB3GIGV1        NA
8.15dBi Colinear Omni Antenna          Antenex                FG9026           NA
(remote)
3dB Attenuator (for 8.15dBi antenna)   Mini-Circuits          BW-N3W5+         NA
                                                                                            Page 4 of 19
                                                                                    Report No: 101674-5


                                                   DATA

                                          Test Setup/Conditions
Test Location:       Brea, Chamber C                   Test Engineer:      Don Nguyen
Configuration:       5, 6, and 7                       Test Date(s):       9/14/2018

                                             Test Equipment
  Asset              Description           Manufacturer            Model         Cal Date          Cal Due
  02043              Field Probe          Amplifier Research      FP2080        5/5/2017          5/5/2019
  00636             Field Monitor         Amplifier Research      FM2000        11/2/2017         11/2/2019

                                          MPE Measurements
                                           Operational Details
Power Reported is:    ☒ Peak ☐ Average
Limit Used is:        ☒ General Population ☐ Occupational Exposure
Operating Band MHz    Power      Ant Gain          EIRP        TX               Antenna Configuration
                      dBm        dBi               dBm         Simultaneous
902.2 to 927.75       29.5       2.8               32.30       Yes              External
902.2 to 927.75       29.5       5.5               35.00       Yes              External
902.2 to 927.75       29.5       8.15 - 3dB        34.65       Yes              External
                                 attenuator
Note: EUT contains modem and Wi-Fi modules transmitting simultaneously at maximum power.

MPE Measurements for Static Fields (Free Space Configuration)
For equipment where the fields are invariant in time, measurements are performed at a fixed height between
1.0m to 1.8m representing worst case measurements as determined by preliminary assessment.

                                              FCC Part 2.1091
Distance   Height Measured              Measured            Measured Exposure      Limit            Result
(m)        (m)    Exposure              Exposure            mW/cm2                 (worst case)
                  mW/cm2                mW/cm2              8.15 dBi antenna-      mW/cm2
                  2.8 dBi antenna       5.5 dBi antenna     3dB attenuator
0.2        1.0    0.1082                0.0119              0.0077                 0.56             Pass
0.2        1.4    0.0192                0.0112              0.0220                 0.56             Pass
0.2        1.8    0.0061                0.0021              0.0024                 0.56             Pass
0.3        1.0    0.0565                0.0099              0.0061                 0.56             Pass
0.3        1.4    0.0126                0.0116              0.0210                 0.56             Pass
0.3        1.8    0.0056                0.0014              0.0021                 0.56             Pass
0.4        1.0    0.0327                0.0089              0.0042                 0.56             Pass
0.4        1.4    0.0095                0.0102              0.0174                 0.56             Pass
0.4        1.8    0.0054                0.0010              0.0019                 0.56             Pass
Note: ISM, modem and Wi-Fi modules transmit simultaneously at highest power.

                                    Limits based on Operating Frequency
Transmitter               Highest power operating frequency range (MHz)     Limit: (mW/cm2)
ISM                       902.4-927.6                                       0.61
Cellular Modem            824.0-849.0                                       0.56
Wi-Fi                     2412-2462                                         1.50


                                                                                                  Page 5 of 19
                                                                                          Report No: 101674-5


                                              RSS-102, Issue 5
Distance   Height Measured              Measured            Measured Exposure        Limit          Result
(m)        (m)    Exposure              Exposure            W/m2                     (worst case)
                       2                     2
                  W/m                   W/m                 8.15 dBi antenna-        W/m2
                  2.8 dBi antenna       5.5 dBi antenna     3dB attenuator
0.2        1.0    1.0823                0.1191              0.0773                   2.6            Pass
0.2        1.4    0.1916                0.1121              0.2197                   2.6            Pass
0.2        1.8    0.0611                0.0208              0.0239                   2.6            Pass
0.3        1.0    0.5654                0.0987              0.0611                   2.6            Pass
0.3        1.4    0.1263                0.1155              0.2101                   2.6            Pass
0.3        1.8    0.0561                0.0140              0.0208                   2.6            Pass
0.4        1.0    0.3268                0.0892              0.0424                   2.6            Pass
0.4        1.4    0.0955                0.1020              0.1740                   2.6            Pass
0.4        1.8    0.0537                0.0096              0.0193                   2.6            Pass
Note: ISM, modem and Wi-Fi modules transmit simultaneously at highest power.

                                 Limits based on Operating Frequency
Transmitter               Highest power operating frequency range (MHz)            Limit: (W/m2)
ISM                       902.4-927.6                                              2.77
Cellular Modem            824.0-849.0                                              2.60
Wi-Fi                     2412-2462                                                5.40

ISO/IEC 17025 Decision Rule
The declaration of pass or fail herein is based upon assessment to the specification(s) listed above, including
where applicable, assessment of measurement uncertainties. For performance related tests, equipment was
monitored for specified criteria identified in that section of testing.




                                                                                                   Page 6 of 19
                                                                                           Report No: 101674-5


Test Setup Photos




      2.8dbi




      2.8dbi




                            Page 7 of 19
                    Report No: 101674-5


5.5dbi




5.5dbi




                 Page 8 of 19
         Report No: 101674-5


8.15dbi




8.15dbi




                  Page 9 of 19
          Report No: 101674-5


                                              Summary

MPE Measurement Results:
Equipment demonstrating compliance with MPE measurement have been evaluated for use under
mobile RF exposure configurations as identified herein. Additional configurations including collocation
or simultaneous transmission with other transmitters (including necessary separation distances) are
subject to further assessment. It is assumed that the manufacturer shall design the equipment such that
the minimum separation distance of 20cm (or greater, as listed above) is met or that the manufacturer
provides a protection guide (e.g. installation instructions) to the end user such that the antenna(s) may
be installed in accordance with the manufacturer’s instructions in such a manor to maintain the
minimum separation distance.

General Comments:
The absorption and distribution of Electromagnetic energy in the body is a very complex phenomena
that depends on the mass, shape and physiological condition of the body; the orientation of the body
with respect to the fields; and, the electrical properties of the body and the environment. Variables that
may play a substantial role in possible biological effects are those that characterize the environment
(including but not limited to: ambient temperature, air velocity, relative humidity and body insulation);
and those that characterize the individual (including but not limited to: age, gender, activity level and
existing debilitation or disease). Because innumerable factors may interact to determine specific
biological effects of exposure to electromagnetic fields, any protection guide should consider both
intended and unintended operational environments and provide guidance for installation and use of the
product such that proper separation distances can be maintained. (ANSI C95.1)




                                                                                             Page 10 of 19
                                                                                      Report No: 101674-5


                                 APPENDIX A - Assessment Procedure


                                               TEST CONFIGURATION

The EUT antenna is placed in a configuration typical of normal installation. Where antenna mounting is required,
non-conductive materials are used for support structures. In the special case of magnetically mounted vehicle
antennas, a reference ground plane is used to simulate actual installation. In order to limit external interference
effects, the test is performed in a semi-anechoic chamber. The EUT equipment is setup in a configuration
representative of normal use. Support equipment for the measurement instruments are located outside of the
testing area.

                                                  TEST PROCEDURE

Measurements are performed using a broadband detector with three orthogonal measurement axes. Values
recorded are RMS based on the maximum measurements. To determine the direction of the maximum
measurement, the detector is moved throughout the RF field generated by the transmit antenna. The detector is
positioned at a minimum of 12 radials and at varying distances from the antenna along each radial. The area of
maximum RF energy determined during preliminary investigation shall be used for the remainder of the tests. In
the case where a transmitter may have multiple frequency bands, the preliminary investigation shall be repeated
for each band.

For time varying fields, the appropriate averaging time is used. For spatially uniform fields, the measurement
height is selected based on maximum preliminary measurements.

For spatially non-uniform fields (e.g. distances close to a magnetically mounted vehicle antenna), spatial averaging
may be performed. The method for performing spatially averaged measurements is as follows:
     1. Determine the direction of the maximum measurement.
     2. At a specific distance measure vertically from the floor 5 points comprising a linear cross section of an
         adult human body, beginning at 0.2m and at each 40cm up to 1.8m.
     3. Calculate the average of the measurements and compare with the established limit.

Since the applicable limits exist in several different measurement units, the following outlines the most common
calculations used for determining the spatially averaged field.

Case 1: Where limits are applied in electric field strength (V/m), the spatially averaged electric field strength along
a grid of n points is calculated using:
                                    1
                      1 n     2
                  E    Ei2 
                       n i 1 

Case 2: Where limits are applied in units of power density (mW/cm2), assuming measurements are made in the far
field, where the E and H vectors are mutually orthogonal, power density is first calculated using:
                         E2
                  S
                        3770

And the spatially averaged power density along a grid of n points is calculated using:
                        1 n
                  S       Si
                        n i 1

                                                                                                        Page 11 of 19
                                                                                                 Report No: 101674-5


The following diagram is an example of the grid used to perform local measurements for RF exposure evaluation
over a whole-body spatial average.




                                                                   1




The following diagram is an example of the setup used for most tests, excluding magnetically mounted vehicle
antennas.




1
    Source: IC GL-01
                                                                                                  Page 12 of 19
                                                                                           Report No: 101674-5


The following diagram is an example of the setup used for vehicle-mounted antennas. In the case where vehicle
glass mounted antennas are used, this setup shall not apply. The letter X represents the test distance used for RF
exposure measurements. The distance X is measured from the phase center of the transmitting antenna to the
volumetric center of the measurement instrument. In order to more accurately simulate normal installation, the
antenna ground plane is not bonded to the ground reference plane. The transmitting antenna is placed in the
center of the antenna ground plane.




                                                                                                    Page 13 of 19
                                                                                             Report No: 101674-5


                                  APPENDIX B - RF Exposure Limits


United States Compliance Requirements (1.1310):

                                        RF Exposure Evaluation Limits
                                      Occupational / Controlled Exposure
Frequency Range         Electric Field       Magnetic Field        Power Density             Averaging Time
(MHz)                   Strength (V/m)       Strength (A/m)        (mW/cm2)                  (minutes)
0.3-3.0                 614                         1.63                *(100)               6
3.0-30                  1842/f                      4.89/f              *(900/f2)            6
30-300                  61.4                        0.163               1                    6
300-1500                ---                         ---                 f/300                6
1500-100,000            ---                         ---                 5.0                  6

                                       RF Exposure Evaluation Limits
                                 General Population / Uncontrolled Exposure
Frequency Range         Electric Field      Magnetic Field       Power Density               Averaging Time
(MHz)                   Strength (V/m)      Strength (A/m)       (mW/cm2)                    (minutes)
0.3-1.34                614                         1.63                *(100)               30
1.34-30                 824/f                       2.19/f              *(180/f2)            30
30-300                  27.5                        0.073               0.2                  30
300-1500                ---                         ---                 f/1500               30
1500-100,000            ---                         ---                 1.0                  30
* Plane wave equivalent power density
Limit is calculated based on the mid-band frequency used in the operating frequency range.

Stand-Alone Evaluation Exemption Levels:
In accordance with KDB 447498 D01 v05r02

                                              Max Output Power at Exemption Limit (mW)
  Frequency
                                    d ≤ 50mm                                        50mm < d ≤ 20cm
    (MHz)
                       1 𝑅 ∙ 50                100                  𝑅 ∙ 50             100                100
     <100               ∙(      ) ∙ (1 + 𝐿𝑂𝐺 (     ))              (       + (𝑑 − 50)      ) ∙ (1 + 𝐿𝑂𝐺 (     ))
                       2 √0.1                 𝑓𝑀𝐻𝑧                   √0.1              150               𝑓𝑀𝐻𝑧
                                                                              𝑅 ∙ 50              𝑓𝑀𝐻𝑧
   100-1500                                                                 (         + (𝑑 − 50)       )
                                        𝑅∙𝑑                                   √𝑓𝐺𝐻𝑧               150
                                    (           )
                                        √𝑓𝐺𝐻𝑧                                  𝑅 ∙ 50
  1500-6000                                                                  (        + (𝑑 − 50) ∙ 10)
                                                                               √𝑓𝐺𝐻𝑧
R is the allowed ratio: 3 for 1-g SAR and 7.5 for 10-g extremity SAR.
d is distance in mm, rounded to the nearest mm.


                                                                                                    Page 14 of 19
                                                                                             Report No: 101674-5


Canadian Compliance Requirements (RSS-102):

                                  RF Exposure Evaluation Limits
                               Occupational / Controlled Exposure:
Frequency Range     Electric Field       Magnetic Field       Power Density     Averaging Time
(MHz)              Strength (V/m)        Strength (A/m)          (W/m2)           (minutes)
0.003-10                 170                 180                  --             Instantaneous
0.1-10                    --                1.6 / f               --                   6
1.29-10               193 / f0.5               --                 --                   6
10-20                   61.4                0.163                 10                   6
20-48                129.8 / f0.5        0.3444 / f0.25       44.72 / f0.5             6
48-100                  49.33               0.1309              6.455                  6
100-6000             15.60 f0.25         0.04138 f0.25        0.6455 f0.5              6
6000-15000               137                0.364                 50                   6
15000-150,000            137                0.364                 50              616000/ f1.2
150,000-300,000       0.354 f0.5         9.40x10-4 f0.5       3.33x10-4 f         616000/ f1.2

                                  RF Exposure Evaluation Limits
                         General Population / Uncontrolled Exposure
Frequency Range     Electric Field       Magnetic Field       Power Density     Averaging Time
(MHz)              Strength (V/m)        Strength (A/m)          (W/m2)           (minutes)
0.003-10                83                   90                    --            Instantaneous
0.1-10                   --                0.73 / f                --                  6
1.1-10                87 / f0.5               --                   --                  6
10-20                  27.46               0.0728                   2                  6
20-48               58.07 / f0.25       0.1540 / f0.25         8.944 / f0.5            6
48-300                 22.06              0.05852                1.291                 6
300-6000            3.142 f0.3417      0.008335 f0.3417      0.02619 f0.6834           6
6000-15000             61.4                 0.163                  10                  6
15000-150,000          61.4                 0.163                  10             616000/ f1.2
150,000-300,000      0.158 f0.5         4.21x10-4 f0.5         6.67x10-5 f        616000/ f1.2




                                                                                      Page 15 of 19
                                                                               Report No: 101674-5


Stand-Alone Evaluation Exemption Levels:

                       Exemption Limits (mW) at Separation Distance (mm)
Freq(MHz)        ≤5   10      15        20      25       30       35       40        45        ≥50
   ≤300          71   101    132       162     193      223      254       284       315       345
    450          52   70      88       106     123      141      159       177       195       213
    835          17   30      42        55      67       80       92       105       117       130
   1900           7   10      18        34      60       99      153       225       316       431
   2450           4    7      15        30      52       83      123       173       235       309
   3500           2    6      16        32      55       86      124       170       225       290
   5800           1    6      15        27      41       56       71       85        97        106


Stand-Alone Evaluation Exemption Levels:

Frequency (MHz)          RF Exposure Exemption Limit (mW)
<20                      1000
20-48                    22480 / f0.5
48-300                   600
300-6000                 1310 f0.6834
≥6000                    5000


General2 Comparison of FCC and IC Exemption Limits




2
    Non-Exhaustive
                                                                                        Page 16 of 19
                                                                                 Report No: 101674-5


Australian Radiation Protection and Nuclear Safety Agency Requirements (ARPANSA):

                                     RF Exposure Evaluation Limits
                                  Occupational / Controlled Exposure:
Frequency Range     Electric Field        Magnetic Field       Power Density   Averaging Time
(MHz)               Strength (V/m)        Strength (A/m)       (W/m2)          (minutes)
0.1 – 1.0           614                   1.63/f             ---               6
1.0-10              614/f                 1.63/f             1000/f2           6
10-400              61.4                  0.163              10                6
400-2000            3.07 * f0.5           0.00814 * f0.5     f/40              6
2000-10,000         137                   0.36               50                6
10,000 – 300,000    137                   0.36               50                9.6x104 / f1.05

                                   RF Exposure Evaluation Limits
                             General Population / Uncontrolled Exposure
Frequency Range     Electric Field      Magnetic Field       Power Density     Averaging Time
(MHz)               Strength (V/m)      Strength (A/m)       (W/m2)            (minutes)
0.10-0.15            86.8                 4.86               ---               6
0.150-1.0            86.8                 0.729/f            --                6
1.0-10               86.8/f0.5            0.729/f            ---               6
10-400               27.4                 0.0729             2                 6
400-2000             1.37 f0.5            0.00364*f0.5       f/200             6
2000-10,000          61.4                 0.163              10                6
10,000 – 300,000     61.4                 0.163              10                9.6x104 / f1.05
*Power density limit applicable >100MHz


Stand-Alone Evaluation Exemption Levels:

Occupational Exposure: 100mW
Portable - General Public: 20mW
Mobile – General Public: Separation distance >20cm and power < ARPANSA RPS3 Table S2
Or according to ARPANSA RPS3 Table S1

                Table S2
Operating Frequency      Nominal Mean Power Output
(MHz)                    (W)
0.1-450                  7
450-2500                 3150 / f




                                                                                      Page 17 of 19
                                                                               Report No: 101674-5


European Union Compliance Requirements (ICNIRP):

                                         RF Exposure Evaluation Limits
                                      Occupational / Controlled Exposure:
Frequency Range         Electric Field        Magnetic Field       Power Density   Averaging Time
(MHz)                   Strength (V/m)        Strength (A/m)       (W/m2)          (minutes)
0.00082-0.065           610                 24.4                 ---               6
0.065-1.0               610                 1.6/f                ---
1.0-10                  610/f               1.6/f                ---               6
10-400                  61                  0.16                 10                6
400-2000                3.0 * f0.5          0.008 * f0.5         f/40              6
2000-300,000            137                 0.36                 50                6

                                       RF Exposure Evaluation Limits
                                 General Population / Uncontrolled Exposure
Frequency Range         Electric Field      Magnetic Field       Power Density     Averaging Time
(MHz)                   Strength (V/m)      Strength (A/m)       (W/m2)            (minutes)
0.003-0.150          87                     5.0                  ---               6
0.150-1.0            87                     0.73/f               --                6
1.0-10               87/f0.5                0.73/f               ---               6
10-400               28                     0.073                2                 6
400-2000             1.375 f0.5             0.0037*f0.5          f/200             6
2000-300,000         61                     0.16                 10                6
*Power density limit applicable >100MHz


Stand-Alone Evaluation Exemption3 Levels:

Head / Body: 20mW
Extremity: 40mW




3
    EN 62479 Annex A, General Public
                                                                                          Page 18 of 19
                                                                                   Report No: 101674-5


                                       APPENDIX C - References


1.    ACMA Radiocommunications (Electromagnetic Radio – Human Exposure) Standard, 2014.
2.    AS/NZS 2772.2, Radiofrequency fields – Principles and method of measurement and computation – 3 kHz to
      300 GHz, 2011.
3.    Australian Radiation Protection and Nuclear Safety Agency, ARPANSA RPS 3, Maximum Exposure Levels to
      Radiofrequency Fields 3 kHz to 300 GHz, 2002 (&Errata, 2003).
4.    New Zealand Standard, NZS 2772.1, Radiofrequency Fields Part 1: Maximum Exposure Levels 3 kHz to 300
      GHz, 2009.
5.    Federal Communications Commission Knowledge Database (KDB) Publication 447498, “What are the RF
      exposure requirements and procedures for mobile and portable devices?” As in effect on the issue date of this
      report.
6.    Title 47 Code of Federal Regulations, Part 1.1310, “Radiofrequency radiation exposure limits.” As in effect on
      the issue date of this report.
7.    Title 47 Code of Federal Regulations, Part 2.1091, “Radiofrequency radiation exposure evaluation: mobile
      devices.” As in effect on the issue date of this report.
8.    ANSI C95.1 (2005) IEEE Standard for Safety Level with Respect to Human Exposure to Radio Frequency
      Electromagnetic Fields, 3kHz to 300 GHz, 2005.
9.    Health Canada Safety Code 6 Limits of Human Exposure to Radiofrequency Electromagnetic Energy in the
      Frequency Range from 3 kHz to 300 GHz, 2015.
10.   Industry Canada GL-01 Guidelines for the Measurement of Radio Frequency Fields at Frequencies From 3 kHz
      to 300 GHz, Issue 3, March 2015.
11.   Industry Canada RSS-102 Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All
      Frequency Bands), Issue 5, March 2015.
12.   EC Council Recommendation 1999/519/EC “On the limitation of exposure of the general public to
      electromagnetic fields (0Hz to 300GHz),” (1999).
13.   European Committee for Electrotechnical Standardization. European Normative, EN 62311 Assessment of
      electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to
      300 GHz), 2008.
14.   European Committee for Electrotechnical Standardization. European Normative, EN 62479 Assessment of the
      compliance of low power electronic and electrical equipment with the basic restrictions related to human
      exposure to electromagnetic fields (10 MHz to 300 GHz), 2010.
15.   International Commission on Non-Ionizing Radiation Protection. Guidelines for Limiting Exposure to Time-
      Varying Electric, Magnetic, and Electromagnetic Fields (up to 300 GHz). Health Physics 74 (4): 494-522; 1998.
16.   International Commission on Non-Ionizing Radiation Protection Statement on the "Guidelines for limiting
      exposure to time-varying electric, magnetic and electromagnetic fields (up to 300 GHz). Health Physics
      97(3):257-259, 2009.




                                                                                                      Page 19 of 19
                                                                                               Report No: 101674-5



Document Created: 2019-03-25 08:09:43
Document Modified: 2019-03-25 08:09:43

© 2024 FCC.report