Spec sheet

FCC ID: EO9MC

Operational Description

Download: PDF
FCCID_284735

functionality profile
 The portable Mobile Collection System is Itron’s latest addition to its industry-leading portfolio
 of Mobile AMR solutions. The Mobile Collection System’s combination of performance,
 portability and affordability represents a significant leap forward for utilities of all types and
 sizes endeavoring to maximize operational efficiency, reduce costs and provide superb
 customer service.

 Simply put, never before has such robust meter reading performance been contained in such
 a convenient and cost-effective package.

 The Mobile Collection System interrogates and receives information from ERT modules
 installed on gas, electric and water meters. The system includes: a transmitter to wake up the
 ERT module, receivers to manage incoming ERT module data transmissions, and a data
 acquisition computer to store meter reading data. It operates on software-selectable utility
 radio frequencies, and is capable of reading ERT modules operating in either “wake-up” or
 “bubble-up” mode.

 A single Mobile Collection System reads an average of 10-12,000 meters in an eight-hour
 shift, and can read up to 16,000 meters per day, depending on meter density and system use.
 It can also read more than one route simultaneously.

 The Mobile Collection System provides unparalleled mobile meter reading performance, yet it
 is small enough to fit in any vehicle and can be easily transferred between vehicles,
 eliminating the need for a dedicated vehicle for meter reading.

 The durable Mobile Collection System is easy to use, featuring a user-friendly interface and
 touch-sensitive display, making training and operation a snap, and is completely compatible
 with Itron meter reading and host processing software.


specifications
 Performance Specifications                                                               - Integrator: an IBM mainframe-based meter reading
   > Operating Frequency:                                                                   management system that can operate and mange
     - Transmitter: 956 MHz MAS Band                                                        Itron’s handheld and mobile technologies. Integrator
     - Receiver: 915 MHz ISM Band                                                           is flexible and expandable, allowing utilities to use
   > Output power: 4 watts peak                                                             metering equipment from more than one
   > Data integrity: verified in every message                                              manufacturer.
 Functional Specifications                                                         RF Exposure
   > Power supply: 12 V DC vehicle power supply                                     > Caution
   > Power consumption: 8A; transmitting mode                                          - To comply with FCC RF exposure requirements, a
   > FCC compliance: Part 101 and Part 15 Class B                                        separation distance of at least 40 cm must be
   > Removable laptop interface                                                          maintained between the antenna of this device
   > Drive: 20 GB hard drive on laptop and 64M CF                                        and all persons.
     nonvolatile backup
                                                                                   Electromagnetic Compatibility
   > Antenna: single, roof mount, omnidirectional
                                                                                     > Caution
   > Display: touch sensitive, color display, Windows 2000
                                                                                       - Approved accessories only must be used with this
   > Hard wired to fuse block for power
                                                                                         equipment. In general, all cables must be high
 Environmental                                                                           quality, shielded, correctly terminated and normally
   > Operating temperature: -4º to 122ºF (-20º to 50ºC)                                  restricted to 2 meters length. The Mobile Collection
   > Storage temperature: -40º to 160ºF (-40º to 71ºC)                                   System adaptor employs special provisions to avoid
   > Humidity limits: 5 to 95% non-condensing relative                                   radio interference and should not be altered or
     humidity                                                                            substituted.
                                                                                       - Unapproved modifications or operation beyond or in
 Physical Specifications
                                                                                         conflict with these instructions for use may void
   > Cabinet dimensions: 13" x 16.5" x 6"
                                                                                         authorization by the authorities to operate the
   > Weight: Mobile Collection System weight approximately
                                                                                         equipment.
     25 lbs
   > The Mobile Collection System comes complete with
     system cabinet, laptop interface, all necessary cabling,                      USA
     mounting hardware, antenna and an instruction                                 Radio Interference, FCC Statement
                                                                                   Note: This equipment has been tested and found to comply with the
     manual.                                                                       limits for a Class B digital device, pursuant to Part 15 of the FCC
                                                                                   Rules. These limits are designed to provide reasonable protection
 Host Processing Software                                                          against harmful interference in a residential installation. This
  > The Mobile Collection System may be used with any of                           equipment generates, uses, and can radiate radio frequency energy
    Itron’s meter reading software applications, which are                         and, if not installed and used in accordance with the instructions,
    sold separately. They include:                                                 may cause harmful interference to radio communications. However,
                                                                                   there is no guarantee that interference will not occur in a particular
           - MV-RS: Itron’s popular meter reading software                         installation. If this equipment does cause harmful interference to
             integrates electronic, off-site and mobile AMR                        radio or television reception, which can be determined by turning the
                                                                                   equipment off and on, the user is encouraged to try to correct the
             functionality into a single software applications                     interference by one or more of the following measures:
           - Premierplus4: this client/server-based application                        - Reorient or relocate the receiving antenna.
                                                                                       - Increase the separation between the equipment and the
             uses industry-standard database networking                                   receiver
             software and offers unprecedented power and                               - Connect the equipment into an outlet on a circuit different
             flexibility. Premierplus4 can operate and manage                             from that to which the receiver is connected.
             Itron’s handheld and mobile technologies in a                             - Consult the dealer or an experienced radio/TV technician
                                                                                          for help.
             single software application
                                                                                   Canada
                                                                                   The digital apparatus does not exceed the class B limits for radio
                                                                                   noise emissions from digital apparatus set out in the Radio
                                                                                   Interference Regulations of the Canadian Department of
                                                                                   Communications, standard ICES-003.



 Itron Inc.
 Corporate Headquarters
 2818 North Sullivan Road
 Spokane, Washington, U.S.A. 99216
 Phone: 1.800.635.5461
 Fax: 1.509.891.3355
 www.itron.com



 Due to continuous research, product improvement and enhancements, Itron reserves the right to change product or system specifications without notice.
 Itron is a registered trademark of Itron Inc. All other trademarks belong to their respective owners. ©Copyright, Itron Inc. 2002



Document Created: 2002-11-15 14:23:37
Document Modified: 2002-11-15 14:23:37