Test Report

FCC ID: EO9IMR

Test Report

Download: PDF
FCCID_3230446

                                                        Itron, Inc.

                                                        TEST REPORT FOR

              AMR Transceiver Device for Communicating with Utility Meters
                                      Model: IMR


                                            Tested o The Following Standards:


                                                    FCC Part 101 Subpart C




                                                       Report No.: 99119-5



                                                Date of issue: November 23, 2016




                                    This test report bears the accreditation symbol indicating that the
                                    testing performed herein meets the test and reporting requirements
                                    of ISO/IEC 17025 under the applicable scope of EMC testing for
                                    CKC Laboratories, Inc.

                                    We strive to create long-term, trust based relationships by providing
                                    sound, adaptive, customer first testing services. We embrace each of
                                    our customers’ unique EMC challenges, not as an interruption to set
                                    processes, but rather as the reason we are in business.




This report contains a total of 23 pages and may be reproduced in full only. Partial reproduction may only be done with the
written consent of CKC Laboratories, Inc.


                                                                  TABLE OF CONTENTS

Administrative Information .......................................................................................................................... 3
   Test Report Information ............................................................................................................................................3
   Report Authorization .................................................................................................................................................3
   Test Facility Information ............................................................................................................................................4
   Software Versions ......................................................................................................................................................4
   Site Registration & Accreditation Information ..........................................................................................................4
   Summary of Results ...................................................................................................................................................5
   Modifications During Testing .....................................................................................................................................5
   Conditions During Testing..........................................................................................................................................5
   Equipment Under Test ...............................................................................................................................................6
   General Product Information.....................................................................................................................................7
FCC Part 15 Subpart C ................................................................................................................................... 8
   101.107 Frequency Stability ......................................................................................................................................8
   101.109 Bandwidth..................................................................................................................................................11
   101.111 Emissions Limitations Conducted ..............................................................................................................14
   101.111 Emissions Limitations Radiated .................................................................................................................18
   101.113 Transmitter Power Limitations ..................................................................................................................21




                                                                                                                                                   Page 2 of 23
                                                                                                                                            Report No.: 99119-5


 d                        b Y ‘Tes    ng the Future
                    LABORATORIES,                INC.




                         ADMINISTRATIVE INFORMATION
                                      Test Report Information

REPORT PREPARED FOR:                                        REPORT PREPARED BY:

Itron, Inc.                                                 Dianne Dudley
2111 N. Molter Road                                         CKC Laboratories, Inc.
Liberty Lake, WA 99019                                      5046 Sierra Pines Drive
                                                            Mariposa, CA 95338


REPRESENTATIVE: Jay Hocomb                                  Project Number: 99119
Customer Reference Number:

DATE OF EQUIPMENT RECEIPT:                                  November 2016
DATE(S) OF TESTING:                                         November 2016



                                        Report Authorization
The test data contained in this report documents the observed testing parameters pertaining to and are relevant
for only the sample equipment tested in the agreed upon operational mode(s) and configuration(s) as identified
herein. Compliance assessment remains the client‘s responsibility. This report may not be used to claim product
endorsement by A2LA or any government agencies. This test report has been authorized for release under quality
control from CKC Laboratories, Inc.




                                                   Steve Behm
                               Director of Quality Assurance & Engineering Services
                                              CKC Laboratories, Inc.




                                                                                                  Page 3 of 23
                                                                                          Report No.: 99119—5


                                Test Facility Information

                                              Our laboratories are configured to effectively test a
                                              wide variety of product types. CKC utilizes first class
                                              test equipment, anechoic chambers, data acquisition
                                              and information services to create accurate, repeatable
                                              and affordable test results.




                                              TEST LOCATION(S):
                                              CKC Laboratories, Inc.
                                              22116 23rd Drive S.E., Suite A
                                              Bothell, WA 98021-4413




                                    Software Versions
CKC Laboratories Proprietary Software                       Version
EMITest Emissions                                           5.03.02




                 Site Registration & Accreditation Information
 Location       CB #          TAIWAN        CANADA             FCC             JAPAN
  Bothell      US0081      SL2-IN-E-1145R   3082C-1           US1022           A-0148




                                                                                       Page 4 of 23
                                                                                Report No.: 99119-5


                                      SUMMARY OF RESULTS
Standard / Specification: FCC Part 101 Subpart C

 Test Procedure       Description                                                   Modifications    Results
 101.107              Frequency Tolerance                                           NA               Pass
 101.109              Bandwidth                                                     NA               Pass
 101.111              Emissions Limitations                                         NA               Pass
 101.113              Peak Power                                                    NA               Pass
 2.1047               Modulation                                                    NA               NA¹
NA = Not applicable
NA¹ = Not applicable because the EUT does not employ any modulation types outlined in the rules.



                                    Modifications During Testing
This list is a summary of the modifications made to the equipment during testing.
 Summary of Conditions
 No modifications were made during testing.

Modifications listed above must be incorporated into all production units.




                                     Conditions During Testing
This list is a summary of the conditions noted to the equipment during testing.
 Summary of Conditions
 None




                                                                                                     Page 5 of 23
                                                                                              Report No.: 99119-5


EQUIPMENT UNDER TEST (EUT)
During testing, numerous configurations may have been utilized. The configurations listed below support
compliance to the standard(s) listed in the Summary of Results section.


Configuration 1

 Equipment Tested:
Device                     Manufacturer           Model #                   S/N
AMR transceiver device for Itron, Inc             IMR                       00000005
communicating with utility
meters
 Support Equipment:
Device                    Manufacturer            Model #                   S/N
Laptop                    Dell                    M6300                     9KG4MF1
AC Adapter for Laptop     Dell                    NADP-130AB D              NA




                                                                                           Page 6 of 23
                                                                                    Report No.: 99119-5


General Product Information:

      Product Information                          Manufacturer-Provided Details
        Equipment Type:                               Stand-Alone Equipment
       Modulation Type(s):                                      OOK
    Antenna Type(s) and Gain:                             Internal PIFA 1dBi
    Antenna Connection Type:         Integral (External connector provided to facilitate testing)
     Nominal Input Voltage:                                 120VAC, 60Hz
Firmware / Software used for Test:             DSP Firmware 5.71 / MC3 Test v4.0.2.2
       Temperature Range                                     -20C to 50C




                                                                                            Page 7 of 23
                                                                                     Report No.: 99119-5


                                FCC Part 101 Subpart C

101.107 Frequency Stability
                                        Test Setup/Conditions
Test Location:      Bothell Lab Bench 2              Test Engineer:        M. Atkinson
Test Method:        FCC CFR 47 Part 101.107, TIA-    Test Date(s):         10/14/16
                    604D
Configuration:      1
Test Setup          Frequency Range: 952-959.85MHz
                    Frequency tested: 952, 959.84MHz

                    Firmware power setting: Max Power
                    EUT Firmware: 5.71
                    Protocol /MCS/Modulation: OOK

                    Antenna type: Internal PIFA
                    Antenna Gain: 1.0 dBi

                    Duty Cycle: 100% (Test Mode)

                    Test Mode: Continuously transmitting
                    Test Setup: EUT is inside temperature chamber transmitting through a temporary antenna
                    connector and is attached directly to the spectrum analyzer.
                    Modifications Added: None

                    Environmental Conditions
Temperature (ºC)     20-24     Relative Humidity (%):      32-45


                                           Test Equipment
     Asset#           Description         Manufacturer          Model            Cal Date        Cal Due
     02871         Spectrum Analyzer        Agilent             E4440A          8/25/2015       8/25/2017
                                                             32026-29801-
    P06678              Cable               Astrolab                            9/19/2016       9/19/2018
                                                              29801-144
    P06242            Attenuator           Weinschel            54A-10          3/28/2016       3/28/2018
                     Temperature
     02757                                   Bemco            F100/350-8        2/5/2015         2/5/2017
                       Chamber
                    Thermometer,
     03029                                    Fluke                566          1/29/2015       1/29/2017
                    Digital Infrared
     01315         AC Power Supply                PPS              N/A         11/16/2015       11/16/2017




                                                                                                Page 8 of 23
                                                                                         Report No.: 99119-5


                              Test Data Summary
                                                Frequency
  Temperature                    Frequency                       Limit
                    Voltage                     Tolerance                  Results
     (ºC)                          (MHz)                          (%)
                                                   (%)
      -30          VNominal      952.0004        0.00004       0.00015
      -20          VNominal      952.0006        0.00003       0.00015
      -10          VNominal      952.0007        0.00001       0.00015
       0           VNominal      952.0010        0.00002       0.00015
       10          VNominal      952.0008        0.00000       0.00015
       20         VMinimum       952.0008        0.00000       0.00015       Pass
       20          VNominal      952.0008        0.00000       0.00015
       20         VMaximum       952.0008        0.00000       0.00015
       30          VNominal      952.0008        0.00000       0.00015
       40          VNominal      952.0008        0.00000       0.00015
       50          VNominal      952.0008        0.00000       0.00015
     Nominal Frequency:          952.0008




                              Test Data Summary
                                                Frequency
  Temperature                    Frequency                       Limit
                    Voltage                     Tolerance                  Results
     (ºC)                          (MHz)                          (%)
                                                   (%)
        -30           VNominal     959.8445      0.00004        0.00015
        -20           VNominal     959.8445      0.00004        0.00015
        -10           VNominal     959.8448      0.00000        0.00015
         0            VNominal     959.8450      0.00002        0.00015
         10           VNominal     959.8450      0.00002        0.00015
         20           VMinimum     959.8448      0.00000        0.00015      Pass
         20           VNominal     959.8448      0.00000        0.00015
         20          VMaximum      959.8448      0.00000        0.00015
         30           VNominal     959.8448      0.00000        0.00015
         40           VNominal     959.8448      0.00000        0.00015
         50           VNominal     959.8448      0.00000        0.00015
      Nominal Frequency:           959.8448
Note: Test was performed with frequency settings that were available at the time of testing
at the lab and are representative of the low and high channels of operation.

Parameter Definitions:

Measurements performed at input voltage Vnominal ± 15%.
 Parameter                 Value
 VNominal:                 115VAC
 VMinimum:                 97VAC
 VMaximum:                 133VAC




                                                                                                     Page 9 of 23
                                                                                              Report No.: 99119-5


Test Data




                  Page 10 of 23
            Report No.: 99119-5


101.109 Bandwidth
                                        Test Setup/Conditions
Test Location:      Bothell Lab C3                   Test Engineer:       M. Atkinson
Test Method:        FCC CFR 47 Part 101.109, TIA-    Test Date(s):        10/10/16
                    604D
Configuration:      1
Test Setup:         Frequency Range: 952-959.85MHz
                    Frequency tested: 952, 959.84MHz

                    Firmware power setting: Max Power
                    EUT Firmware: 5.71
                    Protocol /MCS/Modulation: OOK

                    Antenna type: Internal PIFA
                    Antenna Gain: 1.0 dBi

                    Duty Cycle: 100% (Test Mode)

                    Test Mode: Continuously transmitting
                    Test Setup: EUT is transmitting through a temporary antenna connector and is attached
                    directly to the spectrum analyzer. Multiple modulation tones investigated, only worst
                    case reported.
                    Modifications Added: None


                    Environmental Conditions
Temperature (ºC)     20-24     Relative Humidity (%):      32-45


                                           Test Equipment
     Asset#           Description         Manufacturer          Model           Cal Date           Cal Due
     02871         Spectrum Analyzer        Agilent             E4440A         8/25/2015          8/25/2017
                                                             32026-29801-
    P06678              Cable               Astrolab                           9/19/2016          9/19/2018
                                                              29801-144
    P06242            Attenuator           Weinschel            54A-10         3/28/2016          3/28/2018




                                        Test Data Summary
Frequency                                   Measured           Limit
                   Modulation                                                           Results
  (MHz)                                       (kHz)            (kHz)
  952.0               OOK                    0.4756            <12.5                     Pass
  959.84              OOK                    0.5094            <12.5                     Pass




                                                                                              Page 11 of 23
                                                                                        Report No.: 99119-5


Plot(s)




 Low




 High



                Page 12 of 23
          Report No.: 99119-5


Test Setup Photo(s)




                            Page 13 of 23
                      Report No.: 99119-5


101.111 Emissions Limitations Conducted
                                        Test Setup/Conditions
Test Location:      Bothell Lab C3                  Test Engineer:        M. Atkinson
Test Method:        FCC CFR 47 Part 101.111, TIA-   Test Date(s):         10/6/16 to 10/12/16
                    604D
Configuration:      1
Test Setup:         Frequency Range: 952-959.85MHz
                    Frequency tested: 9kHz-10GHz
                    Firmware power setting: Max Power
                    EUT Firmware: 5.71
                    Protocol /MCS/Modulation: OOK

                    Antenna type: Internal PIFA
                    Antenna Gain: 1.0 dBi

                    Duty Cycle: 100% (Test Mode)

                    Test Mode: Continuously transmitting
                    Test Setup: EUT is transmitting through a temporary antenna connector and is attached
                    directly to the spectrum analyzer. Multiple modulation tones investigated, only worst
                    case reported.
                    Modifications Added: None


                    Environmental Conditions
Temperature (ºC)     20-24     Relative Humidity (%):     32-45

                                       Test Equipment Radiated
     Asset#           Description         Manufacturer          Model           Cal Date         Cal Due
     02871         Spectrum Analyzer        Agilent             E4440A         8/25/2015        8/25/2017
                                                             32026-29801-
    P06503              Cable               Astrolab                           4/28/2016        4/28/2018
                                                               29801-36
    P06242            Attenuator           Weinschel            54A-10         3/28/2016        3/28/2018




                                                                                            Page 14 of 23
                                                                                      Report No.: 99119-5


                                         Test Data Summary
Limit applied: Part 101.111 (a) (2) (i)
Max Power – (35 + 0.8(P − 50) + 10Log10 B) down to -13dBm

P = Percent removed from the center frequency of the transmitter bandwidth.
B = Authorized bandwidth in MHz
                              Measured                 Limit             Margin
    Frequency (MHz)                                                                    Results
                                (dBm)                 (dBm)                (dB)
        959.854                  -12.3                  -9.6               -2.7         Pass
         952.01                  -14.7                  -11                -3.7         Pass
        959.851                   0.5                    4.7               -4.2         Pass
        959.838                   -0.1                   4.8               -4.9         Pass
        952.007                   0.9                    5.8               -4.9         Pass
        951.995                   -0.2                   4.7               -4.9         Pass
        959.836                   -13                    -8                 -5          Pass
        951.992                  -15.4                 -10.1               -5.3         Pass
          2856                   -26.8                  -13               -13.8         Pass
          2880                   -33.8                  -13               -20.8         Pass


                                                 Plot(s)




                                                                                        Page 15 of 23
                                                                                  Report No.: 99119-5


Emissions Mask




                       Page 16 of 23
                 Report No.: 99119-5


Test Setup Photo(s)




                            Page 17 of 23
                      Report No.: 99119-5


101.111 Emissions Limitations Radiated
                                          Test Setup/Conditions
Test Location:        Bothell Lab C3                  Test Engineer:         M. Atkinson
Test Method:          FCC CFR 47 Part 101.111, TIA-   Test Date(s):          10/6/16 to 10/12/16
                      604D
Configuration:         1
Test Setup:           Frequency Range: 952-959.85MHz
                      Frequency tested: 9kHz-10GHz
                      Firmware power setting: Max Power
                      EUT Firmware: 5.71
                      Protocol /MCS/Modulation: OOK

                      Antenna type: Internal PIFA
                      Antenna Gain: 1.0 dBi

                      Duty Cycle: 100% (Test Mode)

                      Test Mode: Continuously transmitting
                      Test Setup: EUT has temporary antenna connector and is connected to termination.
                      Multiple modulation tones investigated, only worst case reported.
                      Modifications Added: None

                      Environmental Conditions
Temperature (ºC)      20 to 24   Relative Humidity (%):     32 to 45


                                        Test Equipment Radiated
  Asset# #            Description         Manufacturer          Model            Cal Date         Cal Due
   02871           Spectrum Analyzer        Agilent             E4440A          8/25/2015       8/25/2017
  P06540                 Cable             Andrews               Heliax         10/29/2015      10/29/2017
  P05305                 Cable             Andrews             ETSI-50T         2/15/2016       2/15/2018
   03540                Preamp                HP                83017A          4/30/2015       4/30/2017
   01467             Horn Antenna           EMCO                 3115           8/12/2015       8/12/2017
                                                             32026-29801-
   P06935                Cable               Astrolab                           3/11/2016          3/11/2018
                                                               29801-18
   03170            High Pass Filter           SMI           HM1155-11SS        12/17/2015      12/17/2017
   00052            Loop Antenna              EMCO               6502            4/8/2016        4/8/2018




                                                                                               Page 18 of 23
                                                                                         Report No.: 99119-5


                                               Test Data Summary
Limit applied: Part 101.111 (a) (2) (i)
Max Power – (35 + 0.8(P − 50) + 10Log10 B) down to -13dBm (EIRP)

P = Percent removed from the center frequency of the transmitter bandwidth.
B = Authorized bandwidth in MHz

Conversion to EIRP limit (dBuV/m at 3m) = Power Limit (dBm) – 20Log10(3) + 107

Note: The limit and measurements were recorded and corrected for dBµV/m at 3m using correction factors
based on known measurement system losses.
 Frequency              Measured                  Limit             Margin
                                                                                        Results
   (MHz)             (dBµV/m at 3m)          (dBµV/m at 3m)           (dB)
    1904                  51.9                     84.5              -28.2               Pass
   0.202                  56.3                     84.5              -32.6               Pass
    0.05                  51.2                     84.5              -33.3               Pass
    2856                  43.5                     84.5              -37.2               Pass
    3808                  43.4                     84.5              -37.8               Pass
  8639.93                 47.3                     84.5              -39.1               Pass
  2879.97                 46.7                     84.5              -39.4               Pass
    4760                   39                      84.5                -41               Pass
  7680.01                 45.4                     84.5                -41               Pass
  9599.93                 45.1                     84.5              -41.1               Pass
    7616                  37.8                     84.5              -41.6               Pass
  8569.05                 37.7                     84.5              -41.7               Pass
  1919.94                 43.5                     84.5              -41.9               Pass
  6720.01                 42.9                     84.5              -42.7               Pass
  9520.75                 35.9                     84.5              -43.3               Pass
    1072                  42.8                     84.5              -45.5               Pass
  4800.01                 42.6                     84.5              -46.7               Pass
    5712                  34.8                     84.5              -46.8               Pass
  5760.01                 41.8                     84.5              -47.8               Pass
  3839.99                 41.2                     84.5              -48.6               Pass
    6664                   34                      84.5              -49.1               Pass
   19.743                 36.7                     84.5              -49.7               Pass
    1333                  35.4                     84.5              -50.5               Pass
   266.7                  32.7                     84.5              -51.8               Pass
   27.511                 31.3                     84.5              -53.2               Pass
   973.8                  31.1                     84.5              -53.4               Pass
    549                   31.1                     84.5              -53.4               Pass
   2.978                  30.6                     84.5              -53.9               Pass
    50.4                  30.3                     84.5              -54.2               Pass




                                                                                          Page 19 of 23
                                                                                    Report No.: 99119-5


Test Setup Photo(s)




     9kHz-1GHz




      1-10GHz




                            Page 20 of 23
                      Report No.: 99119-5


101.113 Transmitter Power Limitations
                                        Test Setup/Conditions
Test Location:      Bothell Lab C3                   Test Engineer:        M. Atkinson
Test Method:        FCC CFR 47 Part 101.113, TIA-    Test Date(s):         10/7/16
                    604D
Configuration:      1
Test Setup:         Frequency Range: 952-959.85MHz
                    Frequency tested: 952, 959.84MHz

                    Firmware power setting: Max Power
                    EUT Firmware: 5.71
                    Protocol /MCS/Modulation: OOK

                    Antenna type: Internal PIFA
                    Antenna Gain: 1.0 dBi

                    Duty Cycle: 100% (Test Mode)

                    Test Mode: Continuously transmitting
                    Test Setup: EUT is transmitting through a temporary antenna connector and is attached
                    directly to the spectrum analyzer. Multiple modulation tones investigated, only worst
                    case reported.
                    Modifications Added: None


                    Environmental Conditions
Temperature (ºC)     20-24     Relative Humidity (%):       32-45


                                           Test Equipment
     Asset#           Description         Manufacturer           Model            Cal Date       Cal Due
     02871         Spectrum Analyzer        Agilent              E4440A          8/25/2015      8/25/2017
                                                              32026-29801-
    P06503              Cable               Astrolab                             4/28/2016      4/28/2018
                                                                29801-36
    P06242            Attenuator           Weinschel             54A-10          3/28/2016      3/28/2018




                                                                                               Page 21 of 23
                                                                                         Report No.: 99119-5


                                          Test Data Summary
               Measured,
                            Correction
 Frequency       before                  Corrected Power                         Limit
                             Factors                         Power Watts                         Results
   (MHz)       correction                     (dBm)                              Watts
                 (dBm)         (dB)
   952.0         12.3         10.3           22.6              0.182             25
                                                                                                 Pass
   959.84        12.3         10.3           22.6              0.182             25
Note: The conducted measurements were recorded in dBuV and converted into dBm using a conversion factor for
known system impedance of 50 ohms.


                                                  Plot(s)




                                                    Low




                                                                                               Page 22 of 23
                                                                                         Report No.: 99119-5


       High

Test Setup Photo(s)




                            Page 23 of 23
                      Report No.: 99119-5



Document Created: 2019-10-16 21:59:34
Document Modified: 2019-10-16 21:59:34

© 2024 FCC.report