Test Report

FCC ID: EO9FC200A

Test Report

Download: PDF
FCCID_796556

                     ADDENDUM TO ITRON, INC. TEST REPORT FC07-038

                                                      FOR THE

                        AUTOMATED METER READING SYSTEM, FC 200

                                   FCC PART 101 PARTIAL TESTING




                                       DATE OF ISSUE: MAY 22, 2007



PREPARED FOR:                                                 PREPARED BY:

Itron, Inc.                                                   Mary Ellen Clayton
2111 N. Molter Rd.                                            CKC Laboratories, Inc.
Liberty Lake, WA 99019                                        5046 Sierra Pines Drive
                                                              Mariposa, CA 95338

P.O. No.: 1343                                                Date of test: April 5-30, 2007
W.O. No.: 86392



                                             Report No.: FC07-038A



This report contains a total of 17 pages and may be reproduced in full only. Partial reproduction may only be done with the
written consent of CKC Laboratories, Inc. The results in this report apply only to the items tested, as identified herein.



                                                                                                          Page 1 of 17
                                                                                               Report No.: FC07-038A


                                                    TABLE OF CONTENTS

Administrative Information .............................................................................................3
Approvals.........................................................................................................................3
Conditions for Compliance ..............................................................................................4
Equipment Under Test (EUT) Description ......................................................................4
Equipment Under Test .....................................................................................................4
Peripheral Devices ...........................................................................................................4
Temperature and Humidity During Testing.....................................................................4
FCC 2.1033(c)(5) Frequency Range................................................................................4
FCC 2.1033(c)(6) Operating Power.................................................................................4
FCC 101.111(a)(5) Emissions Mask ...............................................................................5
Occupied Bandwidth –20dBc ..........................................................................................11
FCC 2.1033(c)(14)/2.1053/101.111(a)(5) - Field Strength of Spurious Radiation .........14




                                                                                                                          Page 2 of 17
                                                                                                               Report No.: FC07-038A


                            ADMINISTRATIVE INFORMATION

DATE OF TEST:                April 5-30, 2007

DATE OF RECEIPT:             April 5, 2007

FREQUENCY RANGE              9 kHz-10 GHz
TESTED:

MANUFACTURER:                Itron, Inc.
                             2111 N. Molter Rd.
                             Liberty Lake, WA 99019

REPRESENTATIVE:              Jeff Gilbert

TEST LOCATION:               CKC Laboratories, Inc.
                             110 Olinda Place
                             Brea, CA 92823

TEST METHOD:                 FCC Part 101

PURPOSE OF TEST:             Original Report: To demonstrate the compliance of the Automated
                             Meter Reading System, FC 200 with partial testing of the
                             requirements for FCC Part 101 devices.
                             Addendum A: To revise the operating power and the format of the
                             radiated spurious emissions data.

APPROVALS:

Steve Behm, Director of Engineering Services

QUALITY ASSURANCE:                                TEST PERSONNEL:




Joyce Walker, Quality Assurance Administrative    Septimiu Apahidean, EMC Engineer
Manager



                                                  Eddie Wong, EMC Engineer

                                                                                  Page 3 of 17
                                                                       Report No.: FC07-038A


CONDITIONS FOR COMPLIANCE
No modifications to the EUT were necessary to comply for the testing that was performed.


EQUIPMENT UNDER TEST (EUT) DESCRIPTION

The customer declares the EUT tested by CKC Laboratories was representative of a production
unit.


EQUIPMENT UNDER TEST

Automated Meter Reading System                     Power Supply
Manuf:     Itron, Inc.                             Manuf:       Lien Engineering
Model:     FC 200                                  Model:       DC72W1P-363A
Serial:    DZGEG6362ZZ7838                         Serial:      2240



PERIPHERAL DEVICES

The EUT was not tested with peripheral devices.




TEMPERATURE AND HUMIDITY DURING TESTING
The temperature during testing was within +15°C and + 35°C.
The relative humidity was between 20% and 75%.


FCC 2.1033 (c)(5) FREQUENCY RANGE
952-960 MHz

FCC 2.1033 (c)(6) OPERATING POWER
3.01 Watts EIRP antenna substitution




                                                                                    Page 4 of 17
                                                                         Report No.: FC07-038A


FCC 101.111(a)(5) EMISSIONS MASK

Test Equipment
    Equipment         Asset #   Manufacturer   Model #       Serial #   Cal Date      Cal Due
Spectrum Analyzer     02462         HP         8568B       2928A04874    091406       091408
RF Section
Spectrum Analyzer     02472         HP          85662A     3001A18430    091406        091408
Display Section
QP Adapter            01437         HP          85650A     3303A01884    091406        091408
Bilog Antenna         00851      Schaffner-    CBL6111C       2629       020206        020208
                                 Chase EMC
Antenna cable         P04382      Andrew       LDF1-50      Cable#17     091906        091908
(10 meter site D)
Antenna cable from    P05569     Pasternack    RG-214/U     Cable #33    022207        022209
bulkhead to antenna
Preamp to SA Cable    P05555     Pasternack    E100316-I    Cable #22    080904        081008
(3 feet)
Pre-amp               00010         HP          8447D      2727A05392    060606        060608

Test Conditions
The battery operated handheld device is placed on the wooden table in upright position with the
antenna installed. Mode: Tx, 952MHz, 956 MHz, 960 MHz, Default Power level setting = 198.
A battery charger is connected to the power input port during the test.


Test Setup Photos




                                                                                    Page 5 of 17
                                                                         Report No.: FC07-038A


101.111 Emission limitations.

(5) When using transmissions employing digital modulation techniques on the 900 MHz multiple
address frequencies with a 12.5 kHz bandwidth, the power of any emission must be attenuated
below the unmodulated carrier power of the transmitter (P) in accordance with the following
schedule:

   (i) On any frequency removed from the center of the authorized bandwidth by a displacement
frequency (fd in kHz) of more than 2.5 kHz up to and including 6.25 kHz: At least 53 log10
(fd/2.5) decibels;

   (ii) On any frequency removed from the center of the authorized bandwidth by a displacement
frequency (fd in kHz) of more than 6.25 kHz up to and including 9.5 kHz: At least 103 log10
(fd/3.9) decibels;

   (iii) On any frequency removed from the center of the authorized bandwidth by a displacement
frequency (fd in kHz) of more than 9.5 kHz up to and including 15 kHz: At least 157 log10
(fd/5.3) decibels; and

   (iv) On any frequency removed from the center of the authorized bandwidth by a displacement
frequency greater than 15 kHz: At least 50 plus 10 log10(P) or 70 decibels, whichever is the
lesser attenuation.




                                                                                    Page 6 of 17
                                                                         Report No.: FC07-038A


Radiated Field Emission mask measured is generated with the following sample calculation at 956MHz

                                                                                                                             RF Field        RF Field
1Frequency   Freq                  Required             Required      dBuV        dBm      P transmit       P density        strength        Strength
                                                                                   at                                                       at 3 meter
 (MHz)       offset                atten (dB)           atten (dB)   at source   source   at source (W)   at 3 meter (W)   at 3 meter (V)    (dBuV)
4.00000         - > 15kHz              50+10Log(p)        44.77        87.0      -20.0    9.9763E-06       8.8210E-08         0.0058          75.2
955.98500             -15kHz           50+10Log(p)        44.77        87.0      -20.0    9.9763E-06       8.8210E-08         0.0058          75.2
955.98500             -15kHz    157 x 10 log(fd/5.3)      70.94        60.8      -46.2    2.4132E-08       2.1337E-10         0.0003          49.1
955.99050             -9.5kHz   157 x 10 log(fd/5.3)      39.79        92.0      -15.0    3.1402E-05       2.7766E-07         0.0102          80.2
955.99050             -9.5kHz   103 x 10 log (fd/3.9)     39.83        91.9      -15.1    3.1153E-05       2.7545E-07         0.0102          80.2
955.99375        -6.25kHz       103 x 10 log (fd/3.9)     21.10       110.7       3.7     2.3254E-03       2.0561E-05         0.0880          98.9
955.99375        -6.25kHz        53 x 10 log(fd/2.5)      19.90       111.9       4.9     3.0647E-03       2.7098E-05         0.1011          100.1
955.99750             -2.5kHz    53 x 10 log(fd/2.5)      0.00        131.8      24.8     2.9929E-01       2.6463E-03         0.9988          120.0
956.00250           +2.5kHz      53 x 10 log(fd/2.5)      0.00        131.8      24.8     2.9929E-01       2.6463E-03         0.9988          120.0
956.00625        +6.25kHz        53 x 10 log(fd/2.5)      19.90       111.9       4.9     3.0647E-03       2.7098E-05         0.1011          100.1
956.00625        +6.25kHz       103 x 10 log (fd/3.9)     21.10       110.7       3.7     2.3254E-03       2.0561E-05         0.0880          98.9
956.00950           +9.5kHz     103 x 10 log (fd/3.9)     39.83        91.9      -15.1    3.1153E-05       2.7545E-07         0.0102          80.2
956.00950           +9.5kHz     157 x 10 log(fd/5.3)      39.79        92.0      -15.0    3.1402E-05       2.7766E-07         0.0102          80.2
956.01500             +15kHz    157 x 10 log(fd/5.3)      70.94        60.8      -46.2    2.4132E-08       2.1337E-10         0.0003          49.1
956.01500             +15kHz           50+10Log(p)        44.77        87.0      -20.0    9.9763E-06       8.8210E-08         0.0058          75.2
9560.00000      + > 15kHz              50+10Log(p)        44.77        87.0      -20.0    9.9763E-06       8.8210E-08         0.0058          75.2




                                                                                                           Page 7 of 17
                                                                                                Report No.: FC07-038A


Power Density (Isotropic)

         Pt
PD =
       4πr 2

PD = Power Density in Watts /m2
Pt = Average Transmit Power
r = Test distance




Field Intensity E (V/m)

 E = PD x 377


       Pt x 377
 E=
        4πr 2

       Pt x 30
 E=
          r2




                                           Page 8 of 17
                                  Report No.: FC07-038


Test Plots

FCC 101.111(a)(5) EMISSIONS MASK - 952 MHz




Tested by: Eddie Wong


FCC 101.111(a)(5) EMISSIONS MASK - 956 MHz




Tested by: Eddie Wong




                                                      Page 9 of 17
                                             Report No.: FC07-038


FCC 101.111(a)(5) EMISSIONS MASK - 960 MHz




Tested by: Eddie Wong




                                                     Page 10 of 17
                                             Report No.: FC07-038


OCCUPIED BANDWIDTH -20dBc


Test Equipment
    Equipment         Asset #   Manufacturer   Model #       Serial #   Cal Date      Cal Due
Spectrum Analyzer     02462         HP         8568B       2928A04874    091406       091408
RF Section
Spectrum Analyzer     02472         HP          85662A     3001A18430    091406       091408
Display Section
QP Adapter            01437         HP          85650A     3303A01884    091406       091408
Bilog Antenna         00851      Schaffner-    CBL6111C       2629       020206       020208
                                 Chase EMC
Antenna cable         P04382      Andrew       LDF1-50      Cable#17     091906       091908
(10 meter site D)
Antenna cable from    P05569     Pasternack    RG-214/U     Cable #33    022207       022209
bulkhead to antenna
Preamp to SA Cable    P05555     Pasternack    E100316-I    Cable #22    080904       081008
(3 feet)
Pre-amp               00010         HP          8447D      2727A05392    060606       060608

Test Conditions
The battery operated handheld device is placed on the wooden table in upright position with the
antenna installed. Mode: Tx, 952MHz, 956 MHz, 960 MHz, Default Power level setting = 198.
A battery charger is connected to the power input port during the test.


Test Setup Photos




                                                                                    Page 11 of 17
                                                                            Report No.: FC07-038


Test Plots

OCCUPIED BANDWIDTH -20dBc - 952 MHz




Tested by: Eddie Wong


OCCUPIED BANDWIDTH -20dBc - 956 MHz




Tested by: Eddie Wong



                                              Page 12 of 17
                                      Report No.: FC07-038


OCCUPIED BANDWIDTH -20dBc - 960 MHz




Tested by: Eddie Wong




                                              Page 13 of 17
                                      Report No.: FC07-038


FCC 2.1033(c)(14)/2.1053/101.111(a)(5)   -   FIELD   STRENGTH   OF    SPURIOUS
RADIATION

Test Setup Photos




                                                                        Page 14 of 17
                                                                Report No.: FC07-038


Toesting the Future


Test Data Sheets

Test Location:      CKC Laboratories, Inc. •110 N Olinda Place • Brea, CA 92823 • 714-993-6112

Customer:           Itron, Inc
Specification:      FCC 101.111 A5 (v)
Work Order #:       86392                                             Date:   4/27/2007
Test Type:          Maximized Emissions                               Time:   14:24:29
Equipment:          Automated Meter Reading System               Sequence#:   25
Manufacturer:       Itron, Inc.                                  Tested By:   Sep Apahidean
Model:              FC 200
S/N:                DZGEG6362ZZ7838
 Test Equipment:
Function                   S/N                Calibration Date       Cal Due Date            Asset #
1.5GHz High Pass Filter    3643A00027         06/27/2005             06/27/2007              02116
Spectrum Analyzer          US44300438         01/03/2007             01/03/2009              02672
Horn Antenna               6246               06/29/2006             06/29/2008              00849
24" SMA Cable              1-40GHz_white      02/16/2007             02/16/2009              P05204
Microwave Pre-amp          3123A00281         07/19/2006             07/19/2008              00786
Heliax Antenna Cable       P5565              09/18/2006             09/18/2008              P05565
 Equipment Under Test (* = EUT):
Function                  Manufacturer                    Model #                     S/N
Automated Meter Reading Itron, Inc.                       FC 200                      DZGEG6362ZZ7838
System*
Power Supply              Lien Engineering                DC72W1P-363A                2240
 Support Devices:
Function                     Manufacturer                 Model #                     S/N
 Test Conditions / Notes:
The battery operated handheld device is placed on the wooden table in upright position with the antenna installed.
Mode: Tx, 952MHz, 956MHz and 960MHz. Modulation turned on. Limit of -26 dBm = 81 dBuV. A battery
charger is connected to the power input port during the test. 22°C, 50% relative humidity. Frequency range of
measurement = 9 kHz - 10 GHz. Frequency 9 - 150 kHz RBW=200 Hz, VBW=200 Hz; 150 kHz - 30 MHz
RBW=9 kHz, VBW=9 kHz; 30 - 1000 MHz RBW=120 kHz, VBW=120 kHz; 1 - 10GHz RBW=1 MHz, VBW=1
MHz.




                                                                                                      Page 16 of 17
                                                                                              Report No.: FC07-038


          Operating Frequency: 952-960 MHz
                     Channels: Low, Mid and High
Highest Measured Output Power:        34.79 ERP(dBm)=          3.01 ERP(Watts)
                     Distance:            3 meters
                         Limit: 43+10Log(P)        47.79 dBc


              Freq. (MHz)       Reference Level (dBm)    Antenna Polarity (H/V)     dBc

               1,909.01                  -30.3                   Vert              65.09
               2,863.37                  -22.8                   Vert              57.59
               3,817.97                   -26                    Vert              60.79
               4,772.38                   -29                    Vert              63.79
               5,727.34                  -38.5                   Vert              73.29
               6,681.37                  -38.4                   Vert              73.19
               1,909.01                  -26.5                   Horiz             61.29
               2,863.77                  -30.7                   Horiz             65.49
               3,817.99                  -23.2                   Horiz             57.99
               4,772.49                  -28.2                   Horiz             62.99
               5,726.92                  -38.5                   Horiz             73.29
               1,911.99                   -27                    Horiz             61.79
               2,868.08                  -30.7                   Horiz             65.49
               3,823.95                  -21.2                   Horiz             55.99
               4,780.12                  -28.6                   Horiz             63.39
               5,736.09                  -39.7                   Horiz             74.49
               6,692.15                  -38.9                   Horiz             73.69
               1,912.04                  -28.7                   Vert              63.49
               2,867.94                  -22.1                   Vert              56.89
               3,824.01                  -28.1                   Vert              62.89
               4,779.99                  -31.8                   Vert              66.59
               5,736.12                  -39.7                   Vert              74.49
               6,691.90                   -39                    Vert              73.79
               1,919.97                  -27.7                   Vert              62.49
               2,879.95                  -24.7                   Vert              59.49
               3,839.96                   -25                    Vert              59.79
               4,800.06                  -26.5                   Vert              61.29
               5,759.79                  -41.3                   Vert              76.09
               6,719.90                  -38.1                   Vert              72.89
               7,679.75                  -37.3                   Vert              72.09
               1,919.97                  -28.3                   Horiz             63.09
               2,879.86                  -33.3                   Horiz             68.09
               3,840.02                  -18.8                   Horiz             53.59
               4,799.91                  -27.9                   Horiz             62.69
               5,759.90                  -39.7                   Horiz             74.49
               6,719.73                  -38.3                   Horiz             73.09
               7,679.79                   -37                    Horiz             71.79




                                                                                    Page 17 of 17
                                                                            Report No.: FC07-038



Document Created: 2007-05-22 09:38:46
Document Modified: 2007-05-22 09:38:46

© 2024 FCC.report